NOTES: 1. SIDE BARRIERS SHALL BE MAINTAINED IN PLACE EXCEPT MAY BE REMOVED WHEN ROLLING STOCK IS ON THE PIT TRACK. BARRIERS ARE TO BE REPLACED BEFORE ROLLING STOCK IS REMOVED FROM THE PIT TRACK. 2. WALKWAYS SHALL BE MAINTAINED AND KEPT FREE FROM VEGETATION. 3. IF PHYSICAL CONDITIONS REQUIRE THE MINIMUM REQUIRED WALKWAY WIDTH FOR NO. 1 TYPE WALKWAYS MAY BE REDUCED TO 2’ MINIMUM UPON APPROVAL OF THE SCRRA DIRECTOR OF ENGINEERING & CONSTRUCTION. 4. FOR DETAILS OF STANDARD ROADBED SECTIONS REFER TO ES2001 & ES2002. 5. BALLAST SHOULDER SHALL BE 9" FOR TIES 9’-0" OR GREATER IN LENGTH AND SHALL BE 12" FOR TIES LESS THAN 9’-0" IN LENGTH. 13’-0" SIDE BARRIERS 6’-6" (REMOVEABLE) SIDE BARRIERS SIDE BARRIERS TRACK C (REMOVEABLE) (REMOVEABLE) C TRACK 4’ -6" 3’ -0" 12 2% 1’ -6" 2% 12 DROP PITS INSPECTION PITS MAXIMUM SLOPE 1:8 4" THICK MINIMUM WALKWAY TYPICAL YARD TRACKS AT ENTRANCES TO BUILDINGS DRAWN BY: A. CARLOS DATE: ASSISTANT DIRECTOR: STANDARDS & DESIGN X REV. XX-XX-XX DATE UserName=> carlosa REVISION DESCRIPTION Date Plotted: 10/5/2011 XX DES. XX ENG. 2:30:26 PM STANDARD 03/31/2011 SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY. DIRECTOR OF ENGINEERING AND CONSTRUCTION Plot Driver=> S:\Plot Drivers\pdf.plt FOR NON-SCRRA APPROVED USES: SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA. ALL RIGHTS RESERVED. ENGINEERING STANDARDS 7001 SCALE: NONE SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012 FileName=> s:\V8EngStds\7000\ES7001-01.dgn WALKWAY CLEARANCE FOR FACILITIES WITH UNDER TRACK PITS REVISION - SHEET 1 OF 2 CADD FILE: ES7001-01 NOTES: 1. IN ALL CASES LATERAL CLEARANCE AND TRACK SPACING WILL MATCH CPUC G.O. 26-D EXCEPT ES7001 AND INSPECTION PITS. 2. WALKWAYS SHALL BE MAINTAINED AND KEPT FREE FROM VEGETATION. 3. IF PHYSICAL CONDITIONS REQUIRE, THE MINIMUM REQUIRED WALKWAY WIDTH FOR NO. 1 TYPE WALKWAYS MAY BE REDUCED TO 2’ MINIMUM UPON APPROVAL OF THE SCRRA DIRECTOR OF ENGINEERING & CONSTRUCTION. 4. FOR DETAILS OF SCRRA STANDARD ROADBED SECTIONS REFER TO ES2001 & ES2002. 5. BALLAST SHOUDER SHALL BE 9" FOR TIES 9’-0" OR GREATER IN LENGTH AND SHALL BE 12" FOR TIES LESS THAN 9’0" IN LENGTH. 6. WHERE PAVING IS USED WITH IN THE WALKWAY AREAS IT SHALL CONFORM TO THE DIMENSIONS AND SLOPES SHOWN FOR CRUSHED ROCK WALKWAYS. 7. ROCKWAY ROCK SHALL BE CRUSHED ROCK IN COFORMANCE WITH AREMA STANDARDS. C TRACK WALKWAY MIN SHOULDER ROCK 8’-6" MIN. 2’-0" 2’-0" MIN. MIN. NO.1 USED AWAY FROM TURNOUTS, ON WORKING PORTION OF TRACKS TYPICAL TRACK CONFIGURATION STORAGE TRACKS GENERAL WALKWAY PER CALIFORNIA P.U.C. STANDARD 1 C TRACK 8’-6" MIN. 6’-0" 6’-0" MIN. MIN. NON - WORKING AISLE TRACK CENTER = 15’-0" NO.6 USED AT TURNOUTS SIMILAR TO, MAIN TRACK AND SIDINGS TYPICAL TRACK CONFIGURATION STORAGE TRACKS DRAWN BY: A. CARLOS DATE: REV. XX-XX-XX DATE UserName=> carlosa REVISION DESCRIPTION Date Plotted: 10/5/2011 XX DES. XX ENG. 2:30:26 PM STANDARD 03/31/2011 SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY. ASSISTANT DIRECTOR: STANDARDS & DESIGN X WALKWAY AT TURNOUTS AND CAR SPOTS PER C.P.U.C. STANDARD 6 DIRECTOR OF ENGINEERING AND CONSTRUCTION Plot Driver=> S:\Plot Drivers\pdf.plt FOR NON-SCRRA APPROVED USES: SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA. ALL RIGHTS RESERVED. ENGINEERING STANDARDS 7001 SCALE: NONE SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012 FileName=> s:\V8EngStds\7000\ES7001-02.dgn WALKWAY CLEARANCE FOR FACILITIES WITHOUT UNDER - TRACK PITS REVISION SHEET - 2 OF 2 CADD FILE: ES7001-02 3’-0" CLEARANCE (TYP.) 60’-0" 85’-0" CAR CTRACK LOCOMOTIVE 5’ -5" (MI N.) 3’-0" 5’ -5" (MI N.) A B A B A 85’-0" (TYP.) 17’-0" PULLING ORIENTATION TYP. 6’ -0" MAX. BUMPING POST OR SPOTTING POINT (TYP.) 6’ -0" MAX. B FACE OF VAULT 85’-0" CAR 60’-0" LOCOMOTIVE 17’-0" TYP. CTRACK FACE OF VAULT A B A B A BUMPING POST OR SPOTTING POINT (TYP.) 3’-0" B PUSHING ORIENTATION 68’-0" 85’-0" (TYP.) TOILET DUMP (TYP.) 3’-0" 77’-0" 85’-0" (TYP.) COMBINED PUSHING & PULLING NOTES: 1. THE "B" END OF CARS IS ALWAYS ON THE LOCOMOTIVE SIDE. 2. THIS ASSUMES SPOTTING TRAINS AT THE SAME LOCATION FOR BOTH PUSHING AND PULLING ORIENTATION. 3. LAYOUT FOR MULTIPLE TRACKS CAN BE MODIFIED TO MINIMIZE THE NUMBER OF TOILET DUMPS. DRAWN BY: A. CARLOS DATE: ASSISTANT DIRECTOR: STANDARDS & DESIGN X REV. XX-XX-XX DATE UserName=> carlosa REVISION DESCRIPTION Date Plotted: 10/5/2011 XX DES. XX ENG. 2:30:27 PM STANDARD 03/31/2011 SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY. DIRECTOR OF ENGINEERING AND CONSTRUCTION Plot Driver=> S:\Plot Drivers\pdf.plt FOR NON-SCRRA APPROVED USES: SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA. ALL RIGHTS RESERVED. ENGINEERING STANDARDS 7101 SCALE: NONE REVISION SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY DUMP STATION LAYOUT - SHEET 1 OF 3 CADD FILE: ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012 FileName=> s:\V8EngStds\7000\ES7101-01.dgn ES7101-01 3'-0" 69'-0" 85'-0" LOCOMOTIVE CAR CTRACK CLEARANCE (TYP.) BUMPING POST OR SPOTTING POINT (TYP.) 6' -0" MAX. 5' -5" (MI N.) B A B A B A FACE OF VAULT 10'-0" 17'-0" TYP. TWO WATER LINES 85'-0" (TYP.) TYP. PULLING ORIENTATION 85'-0" CAR 6' -0" MAX. 5' -5" (MI N.) 3'-0" 17'-0" TWO WATER LINES TYP. CTRACK FACE OF VAULT A B A 68'-0" B A B 85'-0" (TYP.) PUSHING ORIENTATION BUMPING POST OR SPOTTING POINT (TYP.) 3'-0" 68'-0" 85'-0" (TYP.) TOILET DUMP (TYP.) WATER STATION PER SCRRA ES7103 (TYP.) 86'-0" 85'-0" (TYP.) TWO WATER LINES TYP. COMBINED PUSHING & PULLING NOTES: 1. THE "B" END OF CARS IS ALWAYS ON THE LOCOMOTIVE SIDE. 2. THIS ASSUMES SPOTTING TRAINS AT THE SAME LOCATION FOR BOTH PUSHING AND PULLING ORIENTATION. 3. LAYOUT FOR MULTIPLE TRACKS CAN BE MODIFIED TO MINIMIZE THE NUMBER OF TOILET DUMPS. DRAWN BY: A. CARLOS DATE: 04/01/03 ASSISTANT DIRECTOR: STANDARDS & DESIGN A REV. $USER$ 12-08-14 DATE ADDED WATER LINES DESCRIPTION Date Plotted: $DATE$ AC DES. $TIME$ NDP ENG. DIRECTOR OF ENGINEERING AND CONSTRUCTION Plot Driver=> $PLTDRVL$ SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY. FOR NON-SCRRA APPROVED USES: SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA. ALL RIGHTS RESERVED. STANDARD ENGINEERING STANDARDS 7101 SCALE: NONE SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012 FileName=> $FILEL$ DUMP STATION AND WATER LINE LAYOUT REVISION SHEET A 1 OF 3 CADD FILE: ES7101-01 NOTE: 1’-7" 2" ALL ALUMINUM TO BE 6061-T6 2" 1’-4" 1" DIA. O.D. x 1" DIA. I.D. 1" SQ. ALUMINUM BAR ALUM. TUBE, MACHINE O.D. TO (3 PLACES) 2" 1.490" DIA. FOR CLEARANCE 4 5 " " 2 PLACES " " 0 3 1’ -7 " " 8 1’ -7 8" " R THRU FINGER " 2-6 HOLE 2-4 " " 1 " 2" 4 7 " 1" x 1" ALUMINUM BAR 1" DIA. O.D. x 1" DIA. I.D. " DIA. x 1" STAINLESS STEEL, 2 2" HEX SETSCREW (6 PLCS) PLAN VIEW ASSEMBLY PLAN VIEW FRAME PLAN VIEW LID / COVER OPEN POSITION " 1" CHAMFER " x 45 TO ALLOW " 1" S.S. HING PIN " 3-1 2-1 " ALUMINUM DIAMOND PLATE 1 1" " 0 COVER TO OPEN PAST 90 TYP 1" DIA. x 1’-5" 2" 2 PLCS 4 PLCS 2" 1 1’-6" - ELEVATION SIDE VIEW SIDE VIEW SEWER DUMP LID ASSEMBLY DETAIL ALUMINUM FRAME ALUMINUM COVER DETAIL 1 DETAIL - DRAWN BY: A. CARLOS DATE: ASSISTANT DIRECTOR: STANDARDS & DESIGN X REV. XX-XX-XX DATE UserName=> carlosa REVISION DESCRIPTION Date Plotted: 10/5/2011 XX DES. XX ENG. 2:30:28 PM - STANDARD 03/31/2011 SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY. DIRECTOR OF ENGINEERING AND CONSTRUCTION Plot Driver=> S:\Plot Drivers\pdf.plt FOR NON-SCRRA APPROVED USES: SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA. ALL RIGHTS RESERVED. 2 ENGINEERING STANDARDS 7101 SCALE: 3" = 1’-0" SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012 FileName=> s:\V8EngStds\7000\ES7101-03.dgn DUMP STATION VAULT ALUMINUM LID DETAILS REVISION - SHEET 3 OF 3 CADD FILE: ES7101-03 INLET FROM TOILET DUMP WATER FLUSH LINE FROM CONTROL VALVE CHAMBER THE PIPE TO BE TERMINATED 18" ABOVE THE INVERT OF SANITARY THE SANITARY SEWER LINE SEWER LINE (FIELD VERIFY) 36" I.D. MANHOLE WITH CAST IRON FRAME AND 30" CAST IRON LID PLAN FLUSHING MANHOLE 6" NAME PLATE "PUSH BUTTON FOR FLUSH CONTROL VALVE NO. " NAME PLATE "LIGHT ON, FLUSH CONTROL VALVE NO. OPEN" CONTROL WIRING TO 6" LAMP (GREEN) 3’-0" 6" STAINLESS STEEL JIC, WATER TIGHT LOCKABLE ENCLOSURE ASCO "RED HAT" CONTROL PANEL SOLENOID VALVE PUSH BUTTON GALVANIZED STEEL ANGLE IRON FRAME 120V AC BRASS UNION VALVE (TYP.) 1" DIA. RIGID CONDUIT 2" DIA. DOMESTIC COPPER 1 3 2 WATER LINE FROM PRESSURE TD VACUUM BREAKER 4’ -0" PB 6" BALL VALVE 6" (TYP.) CHECK VALVE (TYP.) 2’ -0" FINISHED GRADE GALVANIZED STEEL BASE PLATE WITH " x 4" "RED HEAD" ANCHORS. TDa 2" DIA. WATER FLUSH LINE TO FLUSHING MANHOLE 5 6 6" SOL 6" TDb CONCRETE FOUNDATION 2’-0" x 1’-0" x 12" DEEP PLAIN CEMENT CONCRETE PEDESTAL SUPPORT FOR THE VALVES 4 L 1’-0" PLAN FLUSHING CONTROL VALVE BOX CHAMBER DRAWN BY: A. CARLOS DATE: REV. XX-XX-XX DATE UserName=> carlosa REVISION DESCRIPTION Date Plotted: 10/5/2011 XX DES. XX ENG. 2:30:28 PM DIRECTOR OF ENGINEERING AND CONSTRUCTION Plot Driver=> S:\Plot Drivers\pdf.plt FOR NON-SCRRA APPROVED USES: SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA. ALL RIGHTS RESERVED. FLUSHING MANHOLE CONTROL PANEL LAYOUT STANDARD 03/31/2011 SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY. ASSISTANT DIRECTOR: STANDARDS & DESIGN X SCHEMATIC DIAGRAM FOR SOLENOID VALVE CONTROL ENGINEERING STANDARDS 7102 SCALE: NONE REVISION SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY FLUSHING MANHOLE DETAILS - SHEET 1 OF 1 CADD FILE: ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012 FileName=> s:\V8EngStds\7000\ES7102.dgn ES7102 3M WHITE 2" WIDE BALL VALVE REFLECTIVE TAPE 4" SQ. STEEL TUBE NOTES: 1. 4" SQUARE TUBE WILL BE SCHEDULE 40 STEEL TUBE. A 2. 4" SQUARE TUBE TO BE PAINTED SAFETY YELLOW. - ƒ" BRASS BALL VALVE 3. 4" SQUARE TUBE WILL BE 72" LONG IF WALL MOUNT ƒ" 90° BRASS ELBO HOSE RACK IS ON THE OPPOSITE SIDE OF WATER SUPPLY LINE AND 84" LONG IF WALL MOUNT HOSE RACK IS ON THE SAME SIDE OF WATER SUPPLY LINE. 4" SQ. STEEL TUBE DRINKING WATER SERVICE TOP OF CARTWAY GREEN PAINTED PIPE FOR CLEANING SERVICE CUSHIONED PIPE VALVE BOX WITH TRAFFIC INSULATED PIPE ƒ" COPPER TYPE "L" PIPE ƒ" UNISTRUT 14" DIA. x 12" DEEP CONCRETE WITH UNISTRUT LOCATION WILL BE COORDINATED WITH LOCAL AGENCY\OWNER. ƒ" DUAL CHECK BLUE PAINTED PIPE FOR UNISTRUT (2 PLCS) 4. BACKFLOW PREVENTER DESIGN, CONSTRUCTION AND FEBCO 810 DB21 CLAMP COVER MARKED "WATER" CLAMPS 2' -0" UNISTRUT 4" PVC TUBE DETAIL "A" 1" DOMESTIC WATER SUPPLY TYPE "L" COPPER 12" DIA. CONCRETE ENCASEMENT FROM BACKFLOW PREVENTER WRAP COPPER PIPE WITH SEE DETAIL PROTECTIVE WRAP WHEN EMBEDDED IN CONCRETE 1" TO ƒ" TRANSITION ƒ" DOMESTIC 1" BALL CURB VALVE PLACE 2 CUBIC FEET OF WATER SUPPLY 5" RADIUS WALL MOUNT HOSE RACK GRAVEL AROUND VALVE 12 GAGE STEEL POWDER COAT FINISH 10" L x 8" W x 6"D ABOVE WATER ELEVATION POTABLE WATER SUPPLY SUPPLY (TYPICAL) 4" SQ. STEEL TUBE 5‚ " BACKFLOW PREVENTER WS 2" MIN. TO BOLT) W ATER SUPPLY PIVOT POINT (SPOT WELD NUT ƒ " DOMESTI C 2" UNION (TYP) MI N. EACH SIDE MI N. LIFTING HANDLE C TRACK (TYP.) TEE W/ THREADED PLUG 9' -2 • " BV OR GV BPE C WITH BLANLET PLAN AT TOP OF 72" LONG STEEL TUBE GV LOCK GUARD CLASP OR LATCH FOR PADLOCK . . . . . . (TYP. OPP.) . . FG 12" MI N. 2" (ALL SIDES TYP. 6" MIN 18" MAX. (TYP) UNISTRUT (2 PLACES) . . . . . TYP. . . . . . . . . 4" SQ. STEEL TUBE 5‚ " 1" 4" . . . 2" . . . PCC PAD UNDISTURBED SOIL (TYP) BACKFLOW PREVENTER ASSEMBLY W ATER SUPPLY THRUST BLOCK (TYP) MIN 1 FT OF PCC FOR SUPPLY LINE (MAIN) PIPE 1•" AND SMALLER MIN 2 FT OF PCC FOR SUPPLY LINE (MAIN) PIPE 2" AND LARGER ƒ " DOMESTI C COMPACTED OR MI N. FROM WM 9' -2 • " SUPPLY LINE (MAIN) #3 "U" TYPE REINF. BAR (TYP) MIN. C TRACK TAPE (TYP) SEE NOTE C FLOW 2'-0" UNISTRUT (2 PLACES) (TYP. OPP.) 5" RADIUS WALL MOUNT HOSE RACK 12 GAGE STEEL POWDER COAT FINISH 10" L x 8" W x 6"D ABOVE WATER PLAN AT TOP OF SUPPLY (TYPICAL) 84" LONG STEEL TUBE (ONE PIECE ENCLOSURE) DRAWN BY: A. CARLOS DATE: 04/01/03 ASSISTANT DIRECTOR: STANDARDS & DESIGN A REV. $USER$ 12-10-14 DATE ADDED WATER LINE AND BACKFLOW PREVENTER DESCRIPTION Date Plotted: $DATE$ AC DES. $TIME$ NDP ENG. DIRECTOR OF ENGINEERING AND CONSTRUCTION Plot Driver=> $PLTDRVL$ SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY. FOR NON-SCRRA APPROVED USES: SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA. ALL RIGHTS RESERVED. STANDARD ENGINEERING STANDARDS 7103 SCALE: NONE REVISION SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY POTABLE WATER STATION A SHEET 1 OF 1 CADD FILE: ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012 FileName=> $FILEL$ ES7103 100’-0" 50’-0" 4 25’-0" 25’-0" END OF PI T 3’-0" START OF PI T 2 CNICHE 8’-0" TYP. 1’-7" 1’-7" TYP. TYP. CPAD CPAD 2’-4" 2’-4" PAD 5 INSPECTION PIT WALL TYP. TYP. 1 CPAD C LIGHTING NICHE (TYP.) 3 1% SLOPE 1% SLOPE 1% SLOPE 1% SLOPE 1% SLOPE CRAIL PI T & CTRACK 4 CRAIL CNICHE 50’-0" BEAM 2 4’-0" 8’-0" TYP. CPAD 3 1 TYP. CNICHE CNICHE TYP. 2 PLCS. CONSTRUCTI ON JOI NT 2 WALL 3’-0" INSPECTION PIT WALL NOTES: 1. LOCATION OF RAIL PADS AND LIGHTING NICHES WILL BE DETERMINED BY RAIL TIE CONFIGURATION LEADING INTO INSPECTION PIT. 2. DIMENSIONS SHOWN ARE FOR A STANDARD INSPECTION PIT, ACTUAL DIMENSIONS TO BE DETERMINED BY ENGINEER. 3. INSPECTION PIT DESIGN BASED ON SOIL BEARING PRESSURE OF 2250 PSF TO 3500 PSF, SITE SPECIFIC CONDITIONS SHOULD BE VERIFIED AND DESIGN ADJUSTED ACCORDINGLY 4. CONCRETE SHALL BE NORMAL WEIGHT - 145 LBS./CU. FT. AND SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS OF 3000 PSI FOR ALL CONCRETE, UNLESS NOTED OTHERWISE. 5. MIXING AND PLACING OF ALL CONCRETE AND SELECTION OF MATERIALS SHALL BE IN ACCORDANCE WITH THE APPLICABLE CODE AND ACI STANDARDS. CEMENT SHALL BE TYPE II CONFORMING TO ASTM C150. WATER FOR MIXING AND CURING SHALL BE FRESH, CLEAN AND POTABLE. CONTINUOUS INSPECTION IS REQUIRED FOR ALL CONCRETE WORK. WATER CEMENT RATION NOT TO EXCEED 0.50. 6. PROPORTIONS OF AGGREGATE TO CEMENT SHALL BE SUCH AS TO PRODUCE A DENSE WORKABLE MIX WHICH CAN BE PLACED WITHOUT SEGREGATION OR EXCESS FREE SURFACE WATER. REFER TO SCRRA STANDARDS AND SPECIFICATIONS FOR AGGREGATES AND PROPORTIONS MIX DESIGNS SHALL BE SUBMITTED TO THE ENGINEER FOR APPROVAL PRIOR TO USE. 7. REINFORCING STEEL SHALL BE DEFORMED STEEL CONFORMING TO THE REQUIREMENTS OF ASTM A615, GRADE 60. REINFORCING STEEL TO BE WELDED SHALL CONFORM TO REQUIREMENTS OF ASTM A706, GRADE 60, UNLESS NOTED OTHERWISE. 8. REINFORCING BARS SHALL BE SPLICED AS SHOWN ON DRAWINGS. ANY ADDITIONAL SPLICING SHALL REQUIRE PRIOR APPROVAL FROM THE ENGINEER OF RECORD. 9. REINFORCING STEEL SHALL HAVE A MINIMUM PROTECTIVE COVERING CONCRETE AS FOLLOWS: A) CONCRETE PLACED DIRECTLY AGAINST EARTH 3" B) CONCRETE PLACED AGAINST FORMS BUT EXPOSED TO EARTH OR WEATHER: BARS LARGER THAN NO. 5 NO. 5 AND SMALLER 2" 1" C) CONCRETE PLACED AGAINST FORMS BUT NOT EXPOSED DIRECTLY TO EARTH OR WEATHER: SLABS AND WALLS ALL OTHERS 1" As per ACI 318-89 10. ALL BARS SHALL BE CLEAN OF RUST, GREASE AND OTHER MATERIALS LIKELY TO IMPAIR BOND. ALL BENDS SHALL BE MADE COLD. DRAWN BY: A. CARLOS DATE: ASSISTANT DIRECTOR: STANDARDS & DESIGN X REV. XX-XX-XX DATE UserName=> carlosa REVISION DESCRIPTION Date Plotted: 10/5/2011 XX DES. XX ENG. 2:30:29 PM STANDARD 03/31/2011 SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY. DIRECTOR OF ENGINEERING AND CONSTRUCTION Plot Driver=> S:\Plot Drivers\pdf.plt FOR NON-SCRRA APPROVED USES: SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA. ALL RIGHTS RESERVED. ENGINEERING STANDARDS 7104 SCALE: 1 4" SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012 FileName=> s:\V8EngStds\7000\ES7104-01.dgn TYPICAL INSPECTION PIT PLAN REVISION - = 1’-0" SHEET 1 OF 5 CADD FILE: ES7104-01 5’-4" 1’-2" 2’-8" 1’ -0" CONST JT EQ. EQ. HOLES FOR U-BOLTS - EQ. C OF KEY EQ. 2’ -8" CLR SECOND 1’ -0" KEY 10" POUR (CENTERED) 4" 1’ -6" 1’ -0" 1" TYP ADD’L 2-#6 3" 8" PL 4" x" x 1’-1" W/ TYP. KEY 2’ -0" FOR NOTES SEE DRAWING ES7104-01. CRAIL RAIL PAD 1’ -0" FI RST POUR 3’ -3" ADD’L 2-#6 C RAIL PAD NON-SHRINK GROUT 4 NOTE: 2’-8" O.C. 6" C NICHE 4" ADD’L 2-#6 ADD’L 2-#6 6" 1’-6" 1" DIA. U-BOLT W/ HEX NUT AND FLAT WASHER 1’-2" TOP OF FTG RAIL (VERIFY SIZE WITH SCRRA) PLAN C 11" ADD’L 2-#6 C WALL 2’-8" 2’-8" 1" DIA. U-BOLT W/ SELF LOCKING #3 @ 12" O.C. CLOSED TIES (FULL HEIGHT OF WALL) C TRACK SECTION VIEW AT CONSTRUCTION JOINT SCALE: 1" = 1’-0" - SECTION VIEW AT CONSTRUCTION JOINT 3 SCALE: 1" = 1’-0" ES7104-01 4 - 1’-4" CWALL - RAIL C EXCEED 3’-3" SINGLE RAIL CLAMP INSTALLED FOR TIGHT FIT AGAINST RAIL " FILLER PLATE, PL 4" x " x 1’-1" 2’ -0" TOP OF RAIL, RAIL NOT SHOWN FOR CLARITY AND ANCHOR SPACING NOT TO ~ 3’ -2⁄ 3’-10" WASHER. NO ANCHOR OVER NICHE C RAIL SEE DETAIL "A" 5 1’-4" NUT OR HEX NUT AND LOCK + 5" - 8" 2 SCALE: 1" = 1’-0" 1’-4" - 4’ -0" TYPICAL SECTION THRU LIGHTING NICHE TRANSITION C " (FOR 136# RAI L) 2’-8" 2’-8" CTRACK NON-SHRINK GROUT LEVELING NUT #3 @ 6" CLOSED TIES AT NICHE 11" ADD’L 2-#7 CONT #3 @ 12" O.C. CLOSED TIES 7" - 2" #6 @ 12" O.C. 2" #6 @ 12" VERT (TYP.) 2 #5 @ 9" HORIZ (TYP.) 2" CLR 6’ -0" 10" CONT 1’-11" MI N ADD’L #5 5’ -2" 10" STOP BARS 2" CLR. OF NICHE OPNG. MI N ADD’L 2-#7 CONT SECTION B NOTE: ROTATE PLATE DURING RAIL INSTALLATION TO ESTABLISH DESIGN TRACK ALIGNMENT AND GAUGE. (TYP) ADD’L 1’ -6" FLOOR SLOPES (SEE PLAN ON SHEET ES7104-01 3" " TYP CLR 1’-0" 1 3-#5 COMPACTED FILL 1 10" CLEAN & ROUGHEN JOINT (TYP) 1 1’ -3" " -5 1’ 1 ES7104-03 1’ -6" 5 4" 2’-0" 3" CLR SUMP DRAIN AS OCCURS (BEYOND) REFER TO PLAN AND DETAIL 1 6" 5’-0" 6’-6" 8" 5’-0" " FILLER PLATE #5 @ 9" O.C. E.W. TOP & BOT. IN-SITU SOIL SAME LAYER, TYP DETAIL A TYPICAL SECTION THRU PIT SCALE: " = 1’-0" 1 RAIL DIRECT FIXATION DETAILS ES7104-01 DRAWN BY: A. CARLOS DATE: REV. XX-XX-XX DATE UserName=> carlosa REVISION DESCRIPTION Date Plotted: 10/5/2011 XX DES. XX ENG. 2:30:29 PM DIRECTOR OF ENGINEERING AND CONSTRUCTION Plot Driver=> S:\Plot Drivers\pdf.plt FOR NON-SCRRA APPROVED USES: SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA. ALL RIGHTS RESERVED. 5 ES7104-01 STANDARD 03/31/2011 SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY. ASSISTANT DIRECTOR: STANDARDS & DESIGN X SCALE: FULL ENGINEERING STANDARDS 7104 SCALE: AS NOTED SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012 FileName=> s:\V8EngStds\7000\ES7104-02.dgn INSPECTION PIT SECTION AND DETAILS REVISION SHEET - 2 OF 5 CADD FILE: ES7104-02 ADD’L 1 - #5 FULL LENGTH TOP & BOTTOM NOTE: 1’-7" ADD’L 1 - #5 (TOP & BOT.) 1’-7" C INSPECTION PIT & SUMP DRAIN DRAIN PIPE 3 3" ADD’L 1-#5 (TOP & BOT.) 4’-0" 10" FOR LIGHTING FIXTURES, REFER TO ELECTRICAL DWG TYP 11" - 1’ -0" GALVANIZED WELDED STEEL GRATING 1" x" TYPE W-15-2 OR EQUAL (OVER ENTIRE SUMP DRAIN) BARS ARE CONTI NUOUS 2’-4" THRU SUMP DRAI N AREA. 2’-4" BOTTOM 1’-7" TOP REGULAR BARS ARE SHOW N. 1’-7" PI T FLOOR 2’-4" 2’ -9" 2’-4" I NSPECTI ON 1’-7" SUMP SUMP 1’-7" L1" x 1" x" FRAME (GALV) WITH (8) " DIA. x 3" MIN. LONG HEADED ANCHORS OR EQUAL 1’-6" ADD’L 1-#5 (TOP & BOT.) 8’-0" 2’ -0" 8’-0" CSUMP DRAIN (TYP) 2’ -3" FOR NOTES SEE DRAWING ES7104-01. C NICHE IN WALL ON C NICHE IN WALL ON OPPOSITE SIDE OPPOSITE SIDE 2’-4" TOP OF PIT FLOOR PLAN - SUMP DRAIN 2 SCALE: 1" = 1’-0" - 1-#5 T&B SHORT BARS (TYP.) 2" 1-#5 T&B FULL LENGTH (TYP) ANGLE FRAME C SUMP DRAIN GALV. STEEL GRATING INSPECTION PIT FLOOR 1 1’ -3" TOP BARS ES7104-01 0" INSPECTION PIT PARTIAL ELEVATION SCALE: 1" = 1’-0" ADD’L 2-#5 EA WAY 1’-6" (ONE EA SIDE OF PIPE) 2" SUMP 0" 9" BOTTOM BARS 6" DRAINAGE PIPE (BY OTHERS) DRAWN BY: A. CARLOS DATE: ASSISTANT DIRECTOR: STANDARDS & DESIGN X REV. XX-XX-XX DATE UserName=> carlosa REVISION DESCRIPTION Date Plotted: 10/5/2011 XX DES. XX ENG. 2:30:30 PM DIRECTOR OF ENGINEERING AND CONSTRUCTION Plot Driver=> S:\Plot Drivers\pdf.plt 3 SCALE: 1" = 1’-0" - STANDARD 03/31/2011 SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY. FOR NON-SCRRA APPROVED USES: SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA. ALL RIGHTS RESERVED. SECTION THRU SUMP DRAIN ENGINEERING STANDARDS 7104 SCALE: AS NOTED SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012 FileName=> s:\V8EngStds\7000\ES7104-03.dgn INSPECTION PIT PARTIAL ELEVATION REVISION SHEET - 3 OF 5 CADD FILE: ES7104-03 NOTE: FOR NOTES SEE DRAWING ES7104-01. DOWELS TO MATCH STAIR STAIR SLAB REINF. ADDITIONAL REINFORCING AT END OF STUB OUT WALL REQUIRED PER SCRRA STANDARD SPECIFICATIONS 1 - C PIT & TRACK 1’ -0" 2 - 1" TYP TYP 2’ -0 " TY P #4 NOSING BAR #5 @ 9" HORIZ (TYP) #6 @ 12" VERT (TYP) 2’ -0 " TY P #5 @ 12" O.C. E.W. TOP & BOT. RAIL COMPACTED FILL 1’ -4" C 11" 8" 9 EQ.RI SERS = 5’ -2" RAIL 1’ -0" C 6’ -6" 11" WALL BEYOND 8 TREADS @ 11" 3’-0" 1’-0" 3 - #5 @ 9" O.C. E.W. TOP & BOT. 2 STAIR 1 PLAN SCALE: 1" = 1’-0" ES7104-01 DOWELS TO MATCH STAIR STAIR SLAB REINF. STAIR & END WALL SECTION 2 SCALE: " = 1’-0" - 3’-10" 1’-4" 1’-4" TOP OF RAIL 5’ - 2" 1’-0" RI SERS = 5’ -2" #6 @12" VERT #5 @ 9" HORIZ 1’-6" DOWELS TO MATCH STAIR SLAB REINF. TYP DOWELS TO MATCH STAIR SLAB REINFORCING 9 EQ SAME LAYER 1’ -4" 1’ -4" 2’ -10" CLEAN AND ROUGHEN #5 @ 9" O.C. E.W. TOP & BOT. WALL SECTION 1 WALL SECTION 3 SCALE: " = 1’-0" - SCALE: " = 1’-0" - DRAWN BY: A. CARLOS DATE: ASSISTANT DIRECTOR: STANDARDS & DESIGN X REV. XX-XX-XX DATE UserName=> carlosa REVISION DESCRIPTION Date Plotted: 10/5/2011 XX DES. XX ENG. 2:30:30 PM STANDARD 03/31/2011 SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY. DIRECTOR OF ENGINEERING AND CONSTRUCTION Plot Driver=> S:\Plot Drivers\pdf.plt FOR NON-SCRRA APPROVED USES: SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA. ALL RIGHTS RESERVED. ENGINEERING STANDARDS 7104 SCALE: AS NOTED SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012 FileName=> s:\V8EngStds\7000\ES7104-04.dgn INSPECTION PIT STAIR PLAN AND SECTION REVISION SHEET - 4 OF 5 CADD FILE: ES7104-04 1’-4" INSERT FOR GUARDRAIL POST (TYP) STEEL GUARDRAIL PAINTED YELLOW DOWELS TO MATCH STAI R REI NF. GUARDRAIL MUST CLEAR PATH OF TRAIN 1’-4" 3’-10" 1’-4" 2-#5 2-#5 #3 @ 12" CLOSED TIES ADD’L 2 - #7 CONT. *2 - #6 (4’-6" LONG) " CHAMFER ( TYP. ) BEAM SECTION 3 SCALE: 1" = 1’-0" #5 @ 9" HORIZ 5’ -2" INSPECTION PIT FLOOR 11" MIN 4 - SCALE: 1" = 1’-0" - 16"x18" BEAM - C RAI L 2" EDGE OF SLAB (BELOW) DOWELS TO MATCH STAIR REINFORCING 4 BOTTOM STAIR RISER (BELOW) 2" WALL BALANCE @ 3" STUB OUT WALL (STIRRUP SPACING) 2" 16" x 18" DEEP BEAM ADD’L 4-#6 (4’-6" LONG) 2 WALL DOWELS TO MATCH VERT. WALL REINF. WALL TYP - BEAM ELEVATION 6 SCALE: " = 1’-0" - 11" #5 @ 9" EA WAY TOP & BOT. DOWELS TO MATCH VERTICAL WALL REINFORCING 2’-6" 3 1 C 1’ -4" COMPACTED FILL ADD’L VERT. BARS & TIES 3" TRACK WALL BEYOND 3’ -1" WALL 3 C #5 @ 12" E.W. TOP & BOT. 1’-0" 4 TREADS @ 11" INSPECTION PIT FLOOR BEYOND (REF) 5 EQ.RI SERS 2’-0" RAI L 6’ -9" 8" 8’ -3" #5 @ 9" HORIZ #6 @ 12" VERT HORIZ. BARS WHICH ARE INSIDE OF 1’-4" WIDE WALL 2’-6" (REF) #6 @ 12" VERT STEEL HANDRAIL PAINTED YELLOW * PLACE ADD’L #6 VERT’S AS REQD TO CLEAR W ALL - #4 NOSING BAR (TYP) FOR NOTES SEE DRAWING ES7104-01. - #6 (4’-6" LONG) 4-#9 BEAM, SEE NOTE: *2 3-#9 2’ -10" 3’ -6" #4 CLOSED STIRRUPS (SEE BEAM ELEVATION) #4 CLOSED STIRRUPS MI N 1’ -6" 24 " 6 STAIR #2 SECTION 1 SCALE: " = 1’-0" - BOTTOM STAIR RISER (BELOW) LOWERED FLOOR 2" 3" 1’ -4" 1 COMPACTED FILL - 1’ -4" COMPACTED FILL PIT FLOOR SLAB REINF PER 1’-6" 2" CLR. LAP 3’ -1" #4 NOSING BAR (TYP) 3’ -6" 1’ -4" INSPECTION PIT FLOOR 5 EQ.RI SERS 4" 1’ - SLOPE 1% 5 DOWELS TO MATCH STAIR SLAB REINF. 1’-0" 4’-4" 1’-0" #5 @ 9" EA WAY TOP & BOT AS SHOWN DOWELS TO MATCH VERTICAL WALL REINFORCING SECTION 2 PLAN AT STAIR #2 SCALE: " = 1’-0" - SCALE: " = 1’-0" DRAWN BY: A. CARLOS DATE: ASSISTANT DIRECTOR: STANDARDS & DESIGN X REV. XX-XX-XX DATE UserName=> carlosa REVISION DESCRIPTION Date Plotted: 10/5/2011 XX DES. 2:30:31 PM XX ENG. 4 DIRECTOR OF ENGINEERING AND CONSTRUCTION Plot Driver=> S:\Plot Drivers\pdf.plt STAIR #2 SECTION 5 SCALE: " = 1’-0" - ES7104-01 STANDARD 03/31/2011 SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY. FOR NON-SCRRA APPROVED USES: SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA. ALL RIGHTS RESERVED. DOWELS TO MATCH VERT. WALL REINF. 2’-0" 02 #5 @ 9" EA WAY TOP & BOT. AS SHOWN LAP 2’ - 0 LA " P 1’ -0" 11" LAP 8’ -3" 2’-0" #5 @ 9" HORIZ (EA. FACE) 3’ -6" 2 - #6 VERT AT END OF EACH STUB OUT WALL STAIR #6 @ 12" VERT (EA. FACE) LAP 2" 3" OF FLOOR) (AT HI GH POI NT 5’ -2" WALL (BEYOND) 2-#5 CONT (AT TOP) CLR WALL #6 @ 12" VERT ABOUT CLR #5 @ 9" HORIZ 1’-0" 2’ -0" ADD’L 3 - #4 HAIRPINS AT TOP OF EACH STUB OUT WALL 4’-4" C SYMM. 8’ -3" 1’-0" 1’-0" 1’-0" 3’-0" 13 TREADS @ 11" EA.= 11’ -11" 2-#6 VERT 2’-6" ENGINEERING STANDARDS 7104 SCALE: AS NOTED SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012 FileName=> s:\V8EngStds\7000\ES7104-05.dgn INSPECTION PIT STAIR PLAN, SECTIONS AND DETAILS REVISION SHEET - 5 OF 5 CADD FILE: ES7104-05 135’-0" NOTES: 12’ -0" 1. TOILET DUMPS SHOWN FOR REFERENCE ONLY. EXACT LOCATIONS TO BE DETERMINED BY SCRRA ENGINEERING STANDARD ES7104. 2. DIMENSIONS SHOWN ARE FOR A STANDARD JACKING PAD, ACTUAL DIMENSIONS TO BE DETERMINED BY ENGINEERING CONTRACTOR. 3. JACKING PAD DESIGN BASED ON SOIL BEARING PRESSURE OF 2250 PSF TO 3500 PSF, SITE SPECIFIC CONDITIONS SHOULD BE VERIFIED AND DESIGN ADJUSTED ACCORDINGLY. 4. CONCRETE SHALL BE NORMAL WEIGHT-145 LBS./CU. FT. AND SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS OF 3000 PSI FOR ALL CONCRETE. 5. MIXING AND PLACING OF ALL CONCRETE AND SELECTION OF MATERIALS SHALL BE IN ACCORDANCE WITH THE APPLICABLE CODE AND ACI STANDARDS. CEMENT SHALL BE TYPE II CONFORMING TO ASTM C150. WATER FOR MIXING AND CURING SHALL BE FRESH, CLEAN AND POTABLE. CONTINUOUS INSPECTION IS REQUIRED FOR ALL CONCRETE WORK. WATER CEMENT RATION NOT MORE THAN 0.50. 6. PROPORTIONS OF AGGREGATE TO CEMENT SHALL BE SUCH AS TO PRODUCE A DENSE WORKABLE MIX WHICH CAN BE PLACED WITHOUT SEGREGATION OR EXCESS FREE SURFACE WATER. REFER TO SCRRA STANDARDS AND SPECIFICATIONS FOR AGGREGATES AND PROPORTIONS. MIX DESIGNS SHALL BE SUBMITTED TO THE ENGINEER FOR APPROVAL PRIOR TO USE. 7. REINFORCING STEEL SHALL BE DEFORMED STEEL CONFORMING TO THE REQUIREMENTS OF ASTM A615, GRADE 60. REINFORCING STEEL TO BE WELDED SHALL CONFORM TO REQUIREMENTS OF ASTM A706, GRADE 60. 8. REINFORCING BARS SHALL BE SPLICED AS SHOWN ON DRAWINGS. ANY ADDITIONAL SPLICING SHALL REQUIRE PRIOR APPROVAL FROM THE ENGINEER OF RECORD. 9. REINFORCING STEEL SHALL HAVE A MINIMUM PROTECTIVE COVERING CONCRETE AS FOLLOWS: 12’ -0" C WHEN SPECIFIED, TOILET DUMP (TYP.) PER SCRRA ENGINEERING STANDARDS ES7101 & ES7102 TO BE LOCATED ON JACKING PAD PER ES7104. JACKING PAD PLAN C OF RAIL C OF RAIL OF TRACK 1 SCALE: " = 1’-0" - C 12’-0" 3’-1" TYP TYP PROVIDE CONTINUOUS POCKET FOR PLACEMENT OF RAIL 3’-1" 2’-5" 2’-5" COF RAIL 2 TYP #7 @ 8" O.C. E.W TOP & BOT. (TYP.) C OF RAIL - A) CONCRETE PLACED DIRECTLY AGAINST EARTH B) CONCRETE PLACED AGAINST FORMS BUT EXPOSED TO EARTH AND WEATHER: BARS LARGER THAN No. 5 2" No. 5 AND SMALLER 1" 9" 1 1 COMPACTED FILL 1 TYP SECTION 1 SCALE: " = 1’-0" - 10. ALL BARS SHALL BE CLEAN OF RUST, GREASE AND OTHER MATERIALS LIKELY TO IMPAIR BOND. ALL BENDS SHALL BE MADE COLD. 11. FOR DETAILS OF RAIL FIXATION, REFER TO DETAIL 5 ON DRAWING ES7106-02. 5’-0" 2’-6" #7 @ 8" O.C. E.W. C) CONCRETE PLACED AGAINST FORMS BUT NOT EXPOSED DIRECTLY TO EARTH OR WEATHER: SLABS AND WALLS 1" ALL OTHERS As per ACI 318-89 1 1’ -6" 1 1 5’-0" 3" STD. 90 HOOK & EXTENSION 2’ -0" #7 @ 8" O.C. E.W 0" 3’-0" 2’-" 12’-0" TRACK (SYMM ABT) IN-SITU SOIL 1’-3" TOILET DUMP FRAME AND COVER SEE DRAWING SET ES7101 FOR DETAILS SUMP PIT EQ. CONT. GALV. L1" x 1" x " W/ " DIA. x 3" WELDED STUDS @ 24" O.C. TOP OF JACKING PAD SLAB EQ. FLANGEWAY " 2’-4" 2" 2 ADDITIONAL #7 X 6’-0" LONG 4 SIDES OF TOILET DUMP SUMP (CENTERED) CONCRETE FILL CRAIL 8" SINGLE RAIL CLAMP INSTALLED FOR TIGHT FIT AGAINST RAIL PL 4" x " x 1’-1" 2" CLR 9" (REF) NOTE: THOROUGHLY COAT ALL ALUMINUM IN CONTACT WITH CONCRETE WITH A COAT OF BITUMINOUS PAINT BEFORE INSTALLING FRAME / COVER ASSEMBLY 1 - 1" DIA. U-BOLT WITH SELF-LOCKING NUT OR HEX NUT AND LOCK WASHER, ANCHOR SPACING NOT TO EXCEED 3’-3" 6" 2’ -9" 2" CLR " FILLER PL 4" DIA. CAST IRON SEWER PIPE NON-SHRINK GROUT PER SCRRA STANDARD SPECIFICATIONS ADD 1-#7 CONT. AT EACH SIDE OF U-BOLT 4" SEWER PIPE SECTION SCALE: 1" = 1’-0" DRAWN BY: A. CARLOS DATE: 2 DETAIL A - SCALE: 1" = 1’-0" - ASSISTANT DIRECTOR: STANDARDS & DESIGN X REV. XX-XX-XX DATE UserName=> carlosa REVISION DESCRIPTION Date Plotted: 10/5/2011 XX DES. 2:30:31 PM XX ENG. STANDARD 03/31/2011 SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY. DIRECTOR OF ENGINEERING AND CONSTRUCTION Plot Driver=> S:\Plot Drivers\pdf.plt FOR NON-SCRRA APPROVED USES: SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA. ALL RIGHTS RESERVED. ENGINEERING STANDARDS 7105 SCALE: AS NOTED SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012 FileName=> s:\V8EngStds\7000\ES7105.dgn JACKING PAD PLAN, SECTIONS AND DETAILS REVISION - SHEET 1 OF 1 CADD FILE: ES7105 60’-0" 20’-0" 20’-0" 20’-0" COLLECTOR PAN 10’ -0" ASSEMBLY TRACK 5’-0" A CLEAN-OUT / POINT OF CONNECTION TO INDUSTRIAL SEWER SYSTEM PLAN AT OIL DRIP COLLECTOR PANS SCALE: " = 1’-0" C PAN DRAIN 2’-0" C TRACK PER MANUFACTURER 6" CROSS DRAIN CONNECT END OF COLLECTION PAN TYP. SLOPE TO YARD DRAIN (TYP.) SLOPE 3" AC (TYP.) 7" x 9" x 10’-0" LONG TIMBERS 2’ -0" TOP OF RAIL COVER VARIES PER MANUFACTURER 3" MIN. PEA BALLAST GRAVEL (TYP) COLLECTOR PANS (TYP. AT CROSS DRAIN) 8" DIA. PVC SCH. 80 (3) 20’-0" SECTIONS 0.8% PLUG DRAIN FOR FUTURE USE TO OIL WATER SEPARATOR SIDE VIEW AT OIL DRIP COLLECTOR PAN SCALE: 1" = 1’-0" DRAWN BY: A. CARLOS DATE: REV. XX-XX-XX DATE UserName=> carlosa REVISION DESCRIPTION Date Plotted: 10/5/2011 XX DES. XX ENG. 2:30:32 PM A SCALE: 1" = 1’-0" - STANDARD 03/31/2011 SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY. ASSISTANT DIRECTOR: STANDARDS & DESIGN X SECTION DIRECTOR OF ENGINEERING AND CONSTRUCTION Plot Driver=> S:\Plot Drivers\pdf.plt FOR NON-SCRRA APPROVED USES: SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA. ALL RIGHTS RESERVED. ENGINEERING STANDARDS 7109 SCALE: AS NOTED SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012 FileName=> s:\V8EngStds\7000\ES7109.dgn OIL DRIP COLLECTOR PANS PLAN, ELEVATION AND SECTION REVISION - SHEET 1 OF 1 CADD FILE: ES7109 NOTES: 1. DEPTH OF ASPHALT CONCRETE TO BE DETERMINED BASED ON SITE SPECIFIC SOIL CONDITIONS. 2. SIZE OF STORM DRAIN AND SANITARY SEWER SYSTEMS ARE TO BE DETERMINED BASED ON SITE SPECIFIC CONDITIONS. 3. LOCATIONS OF STORM DRAINS AND SLOPE FOR ROADWAYS TO BE DETERMINED BASED ON SITE SPECIFIC CONDITIONS. ROADWAY / YARD LIGHTING PER ES1560 12'-0" 10'-0" C YARD TRACK C ACCESS ROAD 5'-0" C C YARD TRACK POTABLE W ATER C ROADW AY PROPERTY C 5'-7•" 5'-0" (N.T.S.) 9'-1•" 5'-7•" (MINIMUM CLEARANCE) FENCE \ ROW 5'-0" 20'-0" 32' -0" (MI N.) 5'-7•" 10'-0" 23'-3" C YARD TRACK 31'-3" ACCESS ROAD 15'-7•" FILTER 2" x 10" REDWOOD 2% HEADER 90% COMPACTED WATER LINE 2% 10" 2% 10" VARI ES 10" FABRIC SUB-GRADE SUB-BALLAST 12" DIA. PERFORATED 1'-6" DRAIN PIPE BALLAST ROADWAY SECTION DRAWN BY: A. CARLOS DATE: 04/01/04 ASSISTANT DIRECTOR: STANDARDS & DESIGN A REV. $USER$ 12-10-14 DATE ADDED WATER LINE DESCRIPTION Date Plotted: $DATE$ AC DES. $TIME$ NDP ENG. DIRECTOR OF ENGINEERING AND CONSTRUCTION Plot Driver=> $PLTDRVL$ SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY. FOR NON-SCRRA APPROVED USES: SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA. ALL RIGHTS RESERVED. STANDARD ENGINEERING STANDARDS 7110 SCALE: 3 8" SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012 FileName=> $FILEL$ TRACK SPACING AT MAINTENANCE FACILITIES REVISION A = 1'-0" SHEET 1 OF 1 CADD FILE: ES7110 CTRACK AT CROSSING IN GRAVEL PAVEMENT AT CROSSING IN ASPHALT PAVEMENT ASPHALT CONCRETE TRANSITION AREA EDGE OF GRADE CROSSING TOP COURSE 1’-0" CROSS TIE FORM FLANGEWAY GREATER THAN 2" TOP OF RAIL WIDE (4" MAX.) LIMIT OF CROSSING 1’-0" SITE PLANS TIE ELEVATION TRANSITION AREA 8% MAX. AS SHOWN ON TYPICAL MEET TOP OF ASPHALT CONCRETE PAVING FILTER FABRIC AS INDICATED ON GRAVEL PAVEMENT DEPTH SLOPE 3:1 AS INDICATED ON SITE PLANS BASE COURSE ASPHALT PAVEMENT 8% MAX. FILTER FABRIC 1 CROSS SECTIONS 1 1 1 2 2 1 2% 1 2% 9" BALLAST COMPACTED SUBGRADE CRUSHED WALKWAY ROCK ON GRAVEL, SEE TYPICAL B A CROSS SECTION - - EMBANKMENT MATERIAL COMPACTED (90%) SUBGRADE: CROWN AT CENTER, SLOPE AWAY AT 2% COMPACTED SUBGRADE SEE NOTE ON ES2006-02 ASPHALT GRADE CROSSING SECTION "A" CROSSING END DETAIL SCALE: " = 1’-0" SCALE: 1" = 1’-0" C EMERGENCY ROAD TOP OF PAVING AT LATERAL 10’-0" 2% VARIES APPROACH TO CROSSING CROSSING (SEE SITE PLAN) 1" TOP COURSE MEET EXISTING 10’-0" EDGE OF GRADE X ASHPALT PROFILE DEFINED BY SPOT 6’-0" HIGH CHAIN ELEVATION AT HIGH POINTS LINK FENCE AND GRATE ELEVATION AT X 1’-0" LOW POINTS SHOWN ON CONCRETE TOP OF PAVING BETWEEN TRACK 8 1 (WHERE SHOWN ON SITE PLANS) GRADING AND DRAINAGE PLANS 2% GROUND 4 MIN. 1 EXISTING GROUND X 4’-0" VERT. CURVE (TYP.) CRUSHED AGGREGATE BASE DRAWN BY: A. CARLOS DATE: REV. XX-XX-XX DATE UserName=> carlosa REVISION DESCRIPTION Date Plotted: 10/5/2011 XX DES. XX ENG. 2:30:33 PM COMPACTED SUB-GRADE GROUND DIRECTOR OF ENGINEERING AND CONSTRUCTION Plot Driver=> S:\Plot Drivers\pdf.plt COMPACTED SUBGRADE SECTION "B" CROSSING TRANSITION DETAIL SCALE: 1" = 1’-0" STANDARD 03/31/2011 SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY. ASSISTANT DIRECTOR: STANDARDS & DESIGN X MATERI AL 3" BASE COURSE EMBANKMENT MEET EXISTING FOR NON-SCRRA APPROVED USES: SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA. ALL RIGHTS RESERVED. ENGINEERING STANDARDS 7111 SCALE: AS NOTED SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012 FileName=> s:\V8EngStds\7000\ES7111.dgn ROADWAY DETAILS AT MAINTENANCE FACILITIES REVISION - SHEET 1 OF 1 CADD FILE: ES7111 NOTES: FIXTURE AND BRACKET SIMILAR TO OTHER SIDE, PROVIDE WHERE SHOWN ON PLAN 1.DEPTH OF FOOTING TO BE DETERMINED BASE ON SITE SPECIFIC SOIL CONDITIONS. 2.REINFORCING SHOWN FOR AESTHETIC PURPOSES ONLY. ACTUAL REINFORCING TO BE DETERMINED BY STRUCTURAL ENGINEER BASED ON SITE SPECIFIC CONDITIONS. 3.PULL BOX TO BE JENSEN PRECAST MODEL NUMBER K2436-FP36-05T OR EQUAL. EXTRUDED ALUMINUM ARM FIXTURE TO BE HUBBELL ROADWAY TYPE CATALOGUE NUMBER - RLCD40H35031135F5 OR EQUAL. 28’-0" ROUND, TAPERED POLE, FINISH TO MATCH FIXTURE 1 3 #12 STRANDED BARE EQPT GROUND TO FIXTURE (N.T.S.) 32’ -0" (MI N.) K HANDHOLE WITH COVER PLATE (MIN. 2" x 7") BOLT COVER 1" GROUT CRIMP LEVELING NUTS 2’ -4" 2’ -3" 1" x 36" x 4" ANCHOR BOLTS, (4 REQUIRED) TOP OF RAIL VARI ES SEE NOTE 1 FINISHED GRADE 2" PVC CONDUIT EXOTHERMIC WELD 24" x 36" x 36" DEEP (NOMINAL) TRAFFIC FLAT WALL STREET PULLBOX FUSEHOLDER LOCATION (SEE NOTE 3) SEE NOTE 2 GROUND ROD " x 10’-0" LONG 2’-0" DRAWN BY: A. CARLOS DATE: ASSISTANT DIRECTOR: STANDARDS & DESIGN X REV. XX-XX-XX DATE UserName=> carlosa REVISION DESCRIPTION Date Plotted: 10/5/2011 XX DES. XX ENG. 2:30:33 PM STANDARD 03/31/2011 SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY. DIRECTOR OF ENGINEERING AND CONSTRUCTION Plot Driver=> S:\Plot Drivers\pdf.plt FOR NON-SCRRA APPROVED USES: SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA. ALL RIGHTS RESERVED. ENGINEERING STANDARDS 7112 SCALE: 1" = 1’-0" SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012 FileName=> s:\V8EngStds\7000\ES7112.dgn LIGHTING AT MAINTENANCE FACILITIES FOUNDATION AND FIXTURE REVISION - SHEET 1 OF 1 CADD FILE: ES7112 AIR COMPRESSOR SCHEDULE COMPRESSOR UNIT NO. LOCATION INTAKE (TYP) 480V 3 DIA. START/STOP CA-1 AUTO ALTERNATOR FLEXIBLE CONNECTOR 0, 3MIC. COALESCING FILTER CA-1 & 2 CA-2 175CFM W/MANUAL/ AUTO DRAIN PACKAGE OUTSIDE (DUPLEX) OUTSIDE (SIMPLEX) RECEIVER REMARKS 10 MICRON FILTER CONTROL PANEL NEMA 4 MOTOR MFR. INGERSOL RAND TYPE 30 MAKE DELIV. MAX. MODEL CFM PSI PSI PSI 72 EA. 175 145 35 EA. 175 140 2000X 20/A20 CUT IN CUT OUT CAPACITY RPM HP VOLTS PHASE CYCLE 150 670 20 EA. 480 3 60 240 145 1050 10 EA. 480 3 60 240 GAL. NEMA 4 STARTER INGERSOL RAND 2545 NEMA 4 STARTER TYPE 30 AFTER COOLER AIR DRYER SCHEDULE PRESSURE GUAGE AUTO DRAIN (TYP) 240 GALLON UNION (TYP) 2" BY-PASS MOTOR SHUT-OFF VALVE RECEIVER UNIT (TYP) ISOLATION PAD NO. PRESSURE REGULATOR (TYP) LOCATION MFR MAKE MODEL TYPE SCFM REMARKS HP VOLTS PHASE CYCLE 115 1 60 FOR OUTSIDE USE 115 1 60 FOR OUTSIDE USE WITH PRESSURE GUAGE 2" HOUSEKEEPING PAD IW " IW 2" SPILL TO F.S. JAY R. SMITH - MODEL 9832 SHALLOW CHANNEL (3.9" H x 6.1" W) AD-1 W/ IRON GRATING AD-2 SEISMIC ANCHOR 3" FLOOR SINK (FS-1) 3" " CINCH BOLTS (TYP) OUTSIDE OUTSIDE ZEKS HEATSINK ZEKS HEATSINK 15OHSE 75HSB REFRIGERATED DRYING 150 REFRIGERATED DRYING 75 HP, 1KW HP, 0.8KW AD-1 & 2 CONNECT TO SITE AIR DRYER UNTREATED STORM SEWER WEATHER PROOF PRESS. NOTE: CONTRACTOR TO PROVIDE ADDITIONAL PIPING SUPPORTS AS NEEDED. CONTACT SET @ 45 F AIR COMPRESSOR/DRYER DETAIL FROM SYSTEM BRASS PLUG VALVE PIPE CLAMP (TYP) SUPPORT SPACER (TYP) FLOW SUPPORT SPACER PRESSURE REGULATOR WITH GUAGE VENTED BALL VALVE & CHICAGO FITTING BRASS PLUG (TYP) VENTED BALL VALVE VALVE & CHICAGO FITTING PIPE CLAMP FROM SYSTEM FLOW BRASS PLUG VALVE 12" MI N. 4’ -0" APPROX. 4’ -0" APPROX. (TYP) FROM SYSTEM FINISHED FLOOR FINISHED FLOOR AIR COMPRESSOR OUTLET (AO-3) DRAWN BY: A. CARLOS AIR COMPRESSOR OUTLET (AO-2) DATE: REV. XX-XX-XX DATE UserName=> carlosa REVISION DESCRIPTION Date Plotted: 10/5/2011 XX DES. XX ENG. 2:30:33 PM DIRECTOR OF ENGINEERING AND CONSTRUCTION Plot Driver=> S:\Plot Drivers\pdf.plt FOR NON-SCRRA APPROVED USES: SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA. ALL RIGHTS RESERVED. AIR COMPRESSOR OUTLET (AO-1) STANDARD 03/31/2011 SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY. ASSISTANT DIRECTOR: STANDARDS & DESIGN X FINISHED FLOOR ENGINEERING STANDARDS 7201 SCALE: NONE SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012 FileName=> s:\V8EngStds\7000\ES7201-01.dgn COMPRESSED AIR PLUMBING SCHEDULE AND DETAILS REVISION - SHEET 1 OF 2 CADD FILE: ES7201-01 10’-0" NOTES: 1.CONTRACTOR TO SUBMIT PAD DETAILS PER SCRRA STANDARD SPECIFICATIONS. 2.FOUNDATION BOLTS SHOULD PROJECT THRU NUTS AT LEAST " TO ALLOW FOR LEVELING. DRYER 5’ -0" 30" x 60" COMPRESSOR PLAN AT SIMPLEX COMPRESSOR FOUNDATION 10’-0" 12’-0" 5’-0" x 8’-0" PORTABLE STORAGE UNIT DRYER 10’ -0" 30" x 84" 240 GAL. 8’ -0" COMPRESSOR PLAN AT COMPRESSOR FOUNDATION DRAWN BY: A. CARLOS DATE: REV. XX-XX-XX DATE UserName=> carlosa REVISION DESCRIPTION Date Plotted: 10/5/2011 XX DES. XX ENG. 2:30:34 PM STANDARD 03/31/2011 SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY. ASSISTANT DIRECTOR: STANDARDS & DESIGN X FOUNDATION PLAN DIRECTOR OF ENGINEERING AND CONSTRUCTION Plot Driver=> S:\Plot Drivers\pdf.plt FOR NON-SCRRA APPROVED USES: SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA. ALL RIGHTS RESERVED. ENGINEERING STANDARDS 7201 SCALE: 3 4" REVISION SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY MISCELLANEOUS EQUIPMENT FOUNDATIONS = 1’-0" SHEET - 2 OF 2 CADD FILE: ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012 FileName=> s:\V8EngStds\7000\ES7201-02.dgn ES7201-02 CB MR A TWO 400A B RECEPTACLES C TO CAB CAR OR LOCOMOTIVE 480V FU1 FU2 400/800A 10A 10A A 8 B PHASE LOSS RELAY GFI PR PROTECTED T1 H2 H3 H4 CB H1 5 250VA 6 480 - 240 / 120 7 X1 X2 8 FU3 15A 120V 3 SW1 START ESD STOP TCTR PR 1 3 1 2 CB GFI 4 TEST CR CR ESD RUN POSITION OUT R CR A1 CR MR A2 MR RF N.O. 480 POWER ON FLOOD G FU4 TCTR 11 9 10A H4 H2 T2 H3 H1 A 50VA 240 - 120 / 24 TCTR LOOP + DRAWN BY: A. CARLOS DATE: REV. XX-XX-XX DATE UserName=> carlosa REVISION DESCRIPTION Date Plotted: 10/5/2011 XX DES. XX ENG. 2:30:34 PM X2 FU5 FU6 5A 5A 10 PERMISSIVE - STANDARD 03/31/2011 SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY. ASSISTANT DIRECTOR: STANDARDS & DESIGN X X1 2 DIRECTOR OF ENGINEERING AND CONSTRUCTION Plot Driver=> S:\Plot Drivers\pdf.plt FOR NON-SCRRA APPROVED USES: SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA. ALL RIGHTS RESERVED. ENGINEERING STANDARDS 7301 SCALE: SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012 FileName=> s:\V8EngStds\7000\ES7301-01.dgn GROUND POWER SYSTEM TYPICAL 600A PANEL SCHEMATIC NONE REVISION - SHEET 1 OF 2 CADD FILE: ES7301-01 BILL OF MATERIAL WAYSIDE POWER CABINET OPERATION: BILL OF MATERIAL (CONT.) BILL OF MATERIAL (CONT.) QTY ITEM DESCRIPTION LEGEND QTY ITEM DESCRIPTION LEGEND QTY ITEM DESCRIPTION 1 CIRCUIT BREAKER, 3 POLE, 600A, 480 VAC, ELECTRONIC TRIP CB 1 CONTACT BLOCK, 1 N.O. & N.C. POWER ON 1 MOUNTING HOOD WITH TWO WAYSIDE POWER JUMPER CABLES CONNECTED TO THE CABCAR OR LOCOMOTIVE: LEGEND 1 CONTACTOR, IEC, 3 POLE, 630A, 480 VAC, COIL VOLTAGE 120 VAC M 1 MUSHROOM HEAD, RED, JUMBO ESD 1 MEYERS HUB, " 2 LUG KIT, 2 x 2 600 MCM M 1 RELAY, 3 POLE, 2 N.O. & 1 N.C., 120 VAC COIL CR 1 CONDUIT NIPPLE, CLOSE x " RF 1 SAFETY SWITCH, 2 POLE, 30A, 240 VAC, NEMA 3R SW1 1 RELAY SOCKET PR 2 LOCK NUT, " 1 DOOR MOUNTED OPERATING MECHANISMS CB 1 RELAY SOCKET TCTR 2 BUSHING INSULATING, " 1 CONTROL TRANSFORMER, 120/24 V T2 1 RELAY, 24 VDC, 3 POLE, 11 PIN TCTR 2 CONNECTOR PR 1. MOVE THE EMERGENCY STOP BUTTON ON THE FRONT OF THE PANEL TO THE RUN POSITION (OUT). 2. MOVE THE CONTROL CIRCUIT KNIFE SWITCH LOCATED ON THE SIDE OF THE WAYSIDE POWER PANEL TO THE CONNECTED POSITION. 3. THE AMBER LIGHT OF THE WAYSIDE POWER CABINET WILL ILLUMINATE WHEN THERE IS CONTINUITY IN THE TRAINLINE CIRCUIT. 4. WHEN TRAINLINE IS ESTABLISHED ENERGIZED THE 480 VOLT POWER TO THE EQUIPMENT BY KEYING ON THE KEY SWITCH LOCATED ON 1 CONTROL TRANSFORMER, 480/120-240 V T1 1 RELAY, PHASE LOSS/ UNDER VOLTAGE, 480 VAC 2 CONNECTOR 1 KEY OPERATED SELECTOR SWITCH, 3 POSITION, SPRING RETURN TO CENTER START 1 GROUND BAR 1 FUSES, TRM-10 F4 1 PUSH BUTTON OPERATOR ESD 4 NAMEPLATE, LARGE NEMA DEVICE 1 FUSES, TRM-15 F3 THE FRONT OF THE WAYSIDE POWER CABINET. 5. WHEN THE 480 VOLT POWER IS ENERGIZED, THE RED LIGHT ON TOP OF THE WAYSIDE POWER PANEL WILL ILLUMINATE, THE AMBER TRAINLINE LIGHT WILL GO OUT, THE RED PUSH BUTTON ABOVE THE KEY SWITCH WILL ILLUMINATE. 1 PILOT LIGHT, AMBER, 120 VAC A 3 NAMEPLATE, 3" x 4", RED WHITE LETTERS 2 FUSES, ATMR-5 F5 & F6 1 PUSH BUTTON, ILLUMINATED, RED, 120 VAC G, STOP 1 ENCLOSURE, NEMA 4", 2 DOOR, LOCKABLE HANDLE 2 FUSES, ATMR-10 F1 & F2 1 CONTACT BLOCK, 1 N.C. ESD 1 BACK PANEL 1 TERMINAL BLOCK, 10 POLE, 30 A 1 CONTACT BLOCK 1 N.O. ESD 1 PENANT FIXTURE 1 CABLE, WELDING, 4/0 2 HOUSING & CABLE ASSEMBLY - PYLE NATIONAL PART No. RPC1736SE1794 OR EQUAL 6. TO SHUT DOWN THE 480 VOLT POWER, PUSH THE RED STOP BUTTON LOCATED ABOVE THE KEY SWITCH. 7. PHASING FOR WAYSIDE POWER SHALL BE SET FOR COUNTER CLOCKWISE. 3’-0" 2’-10" 4" 1’-6" 1’-6" " TRAIN LINE MEYERS HUB O.K. (AMBER) 2 " NPT 9" 8" EMERGENCY STOP 2’-4" (RED) EMERGENCY SHUTDOWN 120 VAC PUSH TO SHUTDOWN PUSH TO TEST STOP BUTTON 480VAC 480 VAC POWER DISCONNECT 9 T1 POWER DISCONNECT (RED) " DISCONNECT 3" CONTROL POWER 1.5" X 2" PANDUIT POWER ON " " 3 DISCONNECT PR " PANEL DOOR PR T2 7" " BRIDGE RECTIFIER BRIDGE TB-1 MR GROUND BAR 4000 A " 1’ -8" TCTR 6" RECEPTACLES 4’ -10 " 4’ -7 T2 TB-1 " " RECTIFIER 1.5" X 2" PANDUIT 4’ -7 2 TCTR 2 5’ -2 1.5" X 2" PANDUIT 5’ -1 " HANDLE ON CB 1.5" X 2" PANDUIT " CONTROL POWER DISCONNECT CR T1 9 " " 10" 3" ALIGN WITH CR 1.5" X 2" PANDUI T 6 2" 2 " KEY SWITCH 6’ - 120 VAC CONTROL DISCONNECT CONTROL DISCONNECT 1’ -2 " E SHUTDOWN 10" 4000 A GROUND BAR 1’ -6" 4" DIA. 1’ -6" 4’ -7 4" RECEPTACLES " 1’-1" 6 2’-9" PANEL DOOR LAYOUT BACK PANEL LAYOUT DRAWN BY: A. CARLOS DATE: ASSISTANT DIRECTOR: STANDARDS & DESIGN X REV. XX-XX-XX DATE UserName=> carlosa REVISION DESCRIPTION Date Plotted: 10/5/2011 XX DES. XX ENG. 2:30:35 PM DIRECTOR OF ENGINEERING AND CONSTRUCTION Plot Driver=> S:\Plot Drivers\pdf.plt RIGHT SIDE PANEL LAYOUT STANDARD 03/31/2011 SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY. FOR NON-SCRRA APPROVED USES: SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA. ALL RIGHTS RESERVED. LEFT SIDE PANEL LAYOUT ENGINEERING STANDARDS 7301 SCALE: 1 1 2" SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012 FileName=> s:\V8EngStds\7000\ES7301-02.dgn GROUND POWER SYSTEM PANEL LAYOUTS REVISION = 1’-0" SHEET - 2 OF 2 CADD FILE: ES7301-02 SPECIFY OVERALL LENGTH 2" 6" INTERCAR JUMPER ASSEMBLIES AS REQUIRED JUMPER CABLES (PERM) COACH CAR (NIC) (PERM) 2" WIDE HALF LAPPED JUMPER CABLES AND 1 - 3/C #10 AWG CONTROL CABLE (TYP.) (QTY. 1) COACH CAR (NIC) (QTY. 2) " COACH CAR (NIC) JUMPER CABLES 3 - #4/0 POWER CABLES TRACK & CAR CLOSED LOOP TO RECEPTACLE/ 2 JUMPER CABLES " SCOTCH #35 YELLOW TAPE CABINET FEMALE PIN PLUG BODY (HYPALON) R86 CAR RECEPTACLE (TYP. 8 PER COACH CAR) NON-METALLIC CABLE BAND R86 CONNECTOR EVERY 18" TOP & BOT. NO. TY-5409 OR EQUAL R86 CONNECTOR CONNECTIONS FROM CONTROL INTERLOCK 480-VOLT CORDSET CLOSED LOOP TO 480V WAYSIDE POWER QUANTITY REQ’D.-2 FOR EACH 480-VOLT WAYSIDE POWER RECEPTACLE BOX OUTLET SYSTEM SHALL OPERATE TO CONTINUOUSLY MONITOR CONTINUITY OF CLOSED LOOP. UPON DETECTION OF AN OPEN CIRCUIT, WAYSIDE SYSTEM SHALL AUTOMATICALLY ACT TO DE-ENERGIZE 480V POWER TO CARS PLAN VIEW - CONTROL INTERLOCK SCHEME FOR 480V STANDBY POWER 480-VOLT OUTLET PIN UTILIZATIONS R86 CONNECTOR R86 CONNECTOR #4/0 MAIN PIN #1 MAIN PIN #1 MAIN PIN #2 MAIN PIN #2 MAIN PIN #3 MAIN PIN #3 AUX. PIN #1 AUX. PIN #1 AUX. PIN #2 AUX. PIN #2 AUX. PIN #3 AUX. PIN #3 PIN CONNECTION AT RECEPTACLE CAR CONNECTION MAIN #1 ‘A’ PHASE OF 480V FEEDER 480-V ‘A’ BUS MAIN #2 ‘B’ PHASE OF 480V FEEDER 480-V ‘B’ BUS MAIN #3 ‘C’ PHASE OF 480V FEEDER 480-V ‘C’ BUS CONTROL INTERLOCK AUX. #1 PIN OF RECEPTACLE AT SYSTEM RELAY (S) OPPOSITE END OF CAR AUX. #1 #10 AUX. #2 GROUND AUX. #3 CHASIS GROUND FUNCTION 480-V POWER 480-V POWER 480-V POWER CONTROL CLOSED LOOP INTERLOCK GROUNDING 480-VOLT CORDSET SCHEMATIC DRAWN BY: A. CARLOS DATE: ASSISTANT DIRECTOR: STANDARDS & DESIGN X REV. XX-XX-XX DATE UserName=> carlosa REVISION DESCRIPTION Date Plotted: 10/5/2011 XX DES. XX ENG. 2:30:35 PM STANDARD 03/31/2011 SCRRA ENGINEERING STANDARDS ARE INTENDED FOR SCRRA APPROVED USES ONLY. DIRECTOR OF ENGINEERING AND CONSTRUCTION Plot Driver=> S:\Plot Drivers\pdf.plt FOR NON-SCRRA APPROVED USES: SCRRA SHALL NOT BE RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF THE DATA OR INFORMATION CONTAINED HEREIN. THE SELECTION AND USE OF THESE STANDARDS IS THE SOLE RESPONSIBILITY OF THE USER AND SHOULD NOT BE USED WITHOUT CONSULTING A REGISTERED PROFESSIONAL ENGINEER. ALL WARRANTIES AND REPRESENTATIONS OF ANY KIND ARE DISCLAIMED. ANYONE MAKING USE OF THIS INFORMATION AGREES THAT IT ASSUMES ALL LIABILITY ARISING FROM SUCH USE. NO PART OF THESE STANDARDS SHOULD BE REPRODUCED OR DISTRIBUTED IN ANY FORM OR BY ANY MEANS WITHOUT THE PRIOR WRITTEN PERMISSION OF SCRRA. ALL RIGHTS RESERVED. ENGINEERING STANDARDS 7302 SCALE: NONE SOUTHERN CALIFORNIA REGIONAL RAIL AUTHORITY ONE GATEWAY PLAZA, 12TH FLOOR, L. A., CA. 90012 FileName=> s:\V8EngStds\7000\ES7302.dgn 480V WAYSIDE POWER CORDSET DETAILS REVISION - SHEET 1 OF 1 CADD FILE: ES7302