QO install - Q-Tran

advertisement
120V (60Hz) - 12V
QO Installation Instructions
PRIMARY
120/115 VAC
5
4
3
2
1
LOW VOLTAGE BREAKERS - LINE SIDE
BLACK
Pri. Bkr.
Sec. Bkr(s).
HOT
STEP 4
The power supply is to be installed so
that it is not likely to be contacted by
people.
Tp
CHOKE
(optional)
STEP 2
Add secondary circuit breaker or choke
if needed. See instructions supplied with
choke or breaker.
STEP 3
Connect Primary and Secondary wires
per wiring diagrams. Make sure all
connections are tight.
SECONDARY
12 VAC
Up to 5 Sec. Breakers
can be used
12V TAP
13V TAP
14V TAP
NEUTRAL
GROUND
GREY
TAP 2 - 115V
WHT/BLK
TAP 1 - 120V
15V TAP
- DASHED LINES INDICATE ELECTRICAL CONTRACTOR WIRING
- MULTIPLE LOADS CAN BE CONNECTED TO THE SAME OR DIFFERENT
TAPS, DEPENDING ON DESIRED OUTPUT VOLTAGE, TO COMPENSATE
FOR VARYING LOAD DISTANCES.
E247732
STEP 6
Install cover and tighten screw(s).
“WARNING - RISK OF FIRE. If installation requires running
wire through a building structure, special wiring methods
are needed. Contact a qualified electrician.
”WARNING - Outdoor Cord-connected unit shall be
connected to a GFCI protected hooded flush type cover
plate recepticle marked “Wet Location”.
“WARNING - Do not use extension cords
The main Secondary Wiring is intended for shallow
burial - less than 6 inches (152 mm)
For Supply connections use wire rated for at least 60C.
*
- USE SECONDARY TERMINAL BLOCKS FOR LOAD CONNECTIONS
GREEN
GROUND
FOR POWER SUPPLY CORD CONNECTION
“WARNING - RISK OF SHOCK. Installed power unit 5 feet
(1.5M) or more from the pool, spa, or fountain. Where the
power unit is installed (a) indoors within 10 feet (3.05) of a
pool, spa, or fountain or (B) outdoors, connect power unit
to a receptacle protected by a GFCI”.
LANDSCAPE POWER SUPPLY
16HW
PRIMARY INPUT
NOTE: When multiple transformers are installed
in one enclosure, please use the above diagram
for each transformer. The terminal blocks and
breakers are numbered along with their
respective transformers.
MODEL
NUMBERS
1. CONNECT THE 120V NEUTRAL WIRE
INTO THE BLOCK LABELED TAP 1 OR
TAP 2 DEPENDING ON INPUT VOLTAGE.
ONLY USE ONE TAP.
2. CONNECT THE BLACK HOTWIRE INTO
TERMINAL BLOCK LABELED "HOT".
QOM-150
QOM-300
QOM-500
QOM-600
QOM-750
QOMD-2X150
QOMD-2X300
QOMD-150/300
LAMP
WATTS
150W
300W
500W
600W
750W
300W
600W
450W
PRI.
LOAD
200VA
400VA
665VA
800VA
1000VA
400VA
800VA
600VA
WIRE TYPE PRI. WIRE COLOR
HOT
BLACK
NEU (TAP 1)
NEU (TAP 2)
GROUND
WHT / BLK
GREY
GREEN
BREAKER MINIMUM AWG
2 0 0 VA
PV
4 0 0 VA
PV
6 6 5 VA
PV
8 0 0 VA
PV
1 0 0 0 VA
PV
4 0 0 VA
PV
8 0 0 VA
PV
6 0 0 VA
PV
5A
14
60W
14
120W
15A
14
180W
20A
12
240W
25A
10
300W
Contact your local Distributor or Q-Tran for Q-Wire,
Q-Click or proper Accessory Kit
www.Q-Tran.com
PH 203-367-8777
12V
10A
SUITABLE FOR USE WITH LOW VOLTAGE
LANDSCAPE LUMINAIRES / FITTINGS
© 2009 Q-Tran, Inc.
AMPS*
* For Input Amps, Divide Primary Load VA by Primary Voltag
SUITABLE FOR INDOOR / OUTDOOR USE
SUITABLE FOR USE WITH SUBMERSIBLE LUMINAIRES
OR SUBEMERSIBLE PUMPS
L
O
A
D
*
( * ) CONNECT TO ANY TAP
OR
STEP 5
The power supply is to be installed and
serviced only by trained service
personnel.
FOR CONDUIT CONNECTION
“WARNING - RISK OF SHOCK. Install power unit 5 feet
(1.5 m) or more from the pool or spa and 10 feet (3.05 m)
or more from a fountain. Where the power unit is installed
within 10 feet (3.05 m) of a pool or spa, connect unit to
GFCI protected branch circuit.”
L
O
A
D
SECONDARY TAPS - COMMON SIDE
STEP 1
Install housing using the built-in support
bracket for surface mounting.
Remember that all Primary and
Secondary wiring should be Class 1 per
the National Electric Code.
WIRING DIAGRAM
FX 203-367-8771
230V (50Hz) - 12V
277V (60Hz) - 12V
QO Installation Instructions
PRIMARY
220/230 VAC
OR
265/277 VAC
BLACK
SECONDARY
12 VAC
5
4
3
2
1
LOW VOLTAGE BREAKERS - LINE SIDE
Pri. Bkr.
HOT
Sec. Bkr(s).
Tp
CHOKE
(optional)
Up to 5 Sec. Breakers
can be used
STEP 2
Add secondary circuit breaker or choke
if needed. See instructions supplied with
choke or breaker.
STEP 3
Connect Primary and Secondary wires
per wiring diagrams. Make sure all
connections are tight.
STEP 4
The power supply is to be installed so
that it is not likely to be contacted by
people.
12V TAP
13V TAP
14V TAP
NEUTRAL
GROUND
WHITE/BLACK
TAP 1
15V TAP
GREEN
- DASHED LINES INDICATE ELECTRICAL CONTRACTOR WIRING
- MULTIPLE LOADS CAN BE CONNECTED TO THE SAME OR DIFFERENT
TAPS, DEPENDING ON DESIRED OUTPUT VOLTAGE, TO COMPENSATE
FOR VARYING LOAD DISTANCES.
PRIMARY INPUT
The main Secondary Wiring is intended for shallow
burial - less than 6 inches (152 mm)
2. CONNECT THE BLACK HOTWIRE INTO
TERMINAL BLOCK LABELED "HOT".
SUITABLE FOR INDOOR / OUTDOOR USE
SUITABLE FOR USE WITH SUBMERSIBLE LUMINAIRES
OR SUBEMERSIBLE PUMPS
QOM-150
QOM-300
QOM-500
QOM-600
QOM-750
QOMD-2X150
QOMD-2X300
QOMD-150/300
LAMP
WATTS
150W
300W
500W
600W
750W
300W
600W
450W
PRI.
LOAD
200VA
400VA
665VA
800VA
1000VA
400VA
800VA
600VA
AMPS*
2 0 0 VA
PV
4 0 0 VA
PV
6 6 5 VA
PV
8 0 0 VA
PV
1 0 0 0 VA
PV
4 0 0 VA
PV
8 0 0 VA
PV
6 0 0 VA
PV
* For Input Amps, Divide Primary Load VA by Primary Voltag
WIRE TYPE PRI. WIRE COLOR
For Supply connections use wire rated for at least 60C.
NOTE: When multiple transformers are installed
in one enclosure, please use the above diagram
for each transformer. The terminal blocks and
breakers are numbered along with their
respective transformers.
MODEL
NUMBERS
1. CONNECT THE 230V OR 277V NEUTRAL
WIRE INTO THE BLOCK LABELED TAP 1
OR TAP 2 DEPENDING ON INPUT
VOLTAGE. ONLY USE ONE TAP.
“WARNING - RISK OF FIRE. If installation requires
running wire through a building structure, special
wiring methods are needed. Contact a qualified
electrician.
*
- USE SECONDARY TERMINAL BLOCKS FOR LOAD CONNECTIONS
LANDSCAPE POWER SUPPLY
16HW
“WARNING - RISK OF SHOCK. Install power unit
5 feet (1.5 m) or more from the pool or spa and
10 feet (3.05 m) or more from a fountain. Where
the power unit is installed within 10 feet (3.05 m)
of a pool or spa, connect unit to GFCI protected
branch circuit.”
L
O
A
D
*
( * ) CONNECT TO ANY TAP
E247732
STEP 6
Install cover and tighten screw(s).
© 2009 Q-Tran, Inc.
TAP 2
GROUND
STEP 5
The power supply is to be installed and
serviced only by trained service
personnel.
SUITABLE FOR USE WITH LOW VOLTAGE
LANDSCAPE LUMINAIRES / FITTINGS
OR
GREY
L
O
A
D
SECONDARY TAPS - COMMON SIDE
STEP 1
Install housing using the built-in support
bracket for surface mounting.
Remember that all Primary and
Secondary wiring should be Class 1 per
the National Electric Code.
WIRING DIAGRAM
HOT
BLACK
NEU (TAP 1)
RED
NEU (TAP 2)
ORANGE
GROUND
GREEN
BREAKER MINIMUM AWG
5A
14
60W
10A
14
120W
15A
14
180W
20A
12
240W
25A
10
300W
Contact your local Distributor or Q-Tran for Q-Wire,
Q-Click or proper Accessory Kit
www.Q-Tran.com
PH 203-367-8777