120V (60Hz) - 12V QO Installation Instructions PRIMARY 120/115 VAC 5 4 3 2 1 LOW VOLTAGE BREAKERS - LINE SIDE BLACK Pri. Bkr. Sec. Bkr(s). HOT STEP 4 The power supply is to be installed so that it is not likely to be contacted by people. Tp CHOKE (optional) STEP 2 Add secondary circuit breaker or choke if needed. See instructions supplied with choke or breaker. STEP 3 Connect Primary and Secondary wires per wiring diagrams. Make sure all connections are tight. SECONDARY 12 VAC Up to 5 Sec. Breakers can be used 12V TAP 13V TAP 14V TAP NEUTRAL GROUND GREY TAP 2 - 115V WHT/BLK TAP 1 - 120V 15V TAP - DASHED LINES INDICATE ELECTRICAL CONTRACTOR WIRING - MULTIPLE LOADS CAN BE CONNECTED TO THE SAME OR DIFFERENT TAPS, DEPENDING ON DESIRED OUTPUT VOLTAGE, TO COMPENSATE FOR VARYING LOAD DISTANCES. E247732 STEP 6 Install cover and tighten screw(s). “WARNING - RISK OF FIRE. If installation requires running wire through a building structure, special wiring methods are needed. Contact a qualified electrician. ”WARNING - Outdoor Cord-connected unit shall be connected to a GFCI protected hooded flush type cover plate recepticle marked “Wet Location”. “WARNING - Do not use extension cords The main Secondary Wiring is intended for shallow burial - less than 6 inches (152 mm) For Supply connections use wire rated for at least 60C. * - USE SECONDARY TERMINAL BLOCKS FOR LOAD CONNECTIONS GREEN GROUND FOR POWER SUPPLY CORD CONNECTION “WARNING - RISK OF SHOCK. Installed power unit 5 feet (1.5M) or more from the pool, spa, or fountain. Where the power unit is installed (a) indoors within 10 feet (3.05) of a pool, spa, or fountain or (B) outdoors, connect power unit to a receptacle protected by a GFCI”. LANDSCAPE POWER SUPPLY 16HW PRIMARY INPUT NOTE: When multiple transformers are installed in one enclosure, please use the above diagram for each transformer. The terminal blocks and breakers are numbered along with their respective transformers. MODEL NUMBERS 1. CONNECT THE 120V NEUTRAL WIRE INTO THE BLOCK LABELED TAP 1 OR TAP 2 DEPENDING ON INPUT VOLTAGE. ONLY USE ONE TAP. 2. CONNECT THE BLACK HOTWIRE INTO TERMINAL BLOCK LABELED "HOT". QOM-150 QOM-300 QOM-500 QOM-600 QOM-750 QOMD-2X150 QOMD-2X300 QOMD-150/300 LAMP WATTS 150W 300W 500W 600W 750W 300W 600W 450W PRI. LOAD 200VA 400VA 665VA 800VA 1000VA 400VA 800VA 600VA WIRE TYPE PRI. WIRE COLOR HOT BLACK NEU (TAP 1) NEU (TAP 2) GROUND WHT / BLK GREY GREEN BREAKER MINIMUM AWG 2 0 0 VA PV 4 0 0 VA PV 6 6 5 VA PV 8 0 0 VA PV 1 0 0 0 VA PV 4 0 0 VA PV 8 0 0 VA PV 6 0 0 VA PV 5A 14 60W 14 120W 15A 14 180W 20A 12 240W 25A 10 300W Contact your local Distributor or Q-Tran for Q-Wire, Q-Click or proper Accessory Kit www.Q-Tran.com PH 203-367-8777 12V 10A SUITABLE FOR USE WITH LOW VOLTAGE LANDSCAPE LUMINAIRES / FITTINGS © 2009 Q-Tran, Inc. AMPS* * For Input Amps, Divide Primary Load VA by Primary Voltag SUITABLE FOR INDOOR / OUTDOOR USE SUITABLE FOR USE WITH SUBMERSIBLE LUMINAIRES OR SUBEMERSIBLE PUMPS L O A D * ( * ) CONNECT TO ANY TAP OR STEP 5 The power supply is to be installed and serviced only by trained service personnel. FOR CONDUIT CONNECTION “WARNING - RISK OF SHOCK. Install power unit 5 feet (1.5 m) or more from the pool or spa and 10 feet (3.05 m) or more from a fountain. Where the power unit is installed within 10 feet (3.05 m) of a pool or spa, connect unit to GFCI protected branch circuit.” L O A D SECONDARY TAPS - COMMON SIDE STEP 1 Install housing using the built-in support bracket for surface mounting. Remember that all Primary and Secondary wiring should be Class 1 per the National Electric Code. WIRING DIAGRAM FX 203-367-8771 230V (50Hz) - 12V 277V (60Hz) - 12V QO Installation Instructions PRIMARY 220/230 VAC OR 265/277 VAC BLACK SECONDARY 12 VAC 5 4 3 2 1 LOW VOLTAGE BREAKERS - LINE SIDE Pri. Bkr. HOT Sec. Bkr(s). Tp CHOKE (optional) Up to 5 Sec. Breakers can be used STEP 2 Add secondary circuit breaker or choke if needed. See instructions supplied with choke or breaker. STEP 3 Connect Primary and Secondary wires per wiring diagrams. Make sure all connections are tight. STEP 4 The power supply is to be installed so that it is not likely to be contacted by people. 12V TAP 13V TAP 14V TAP NEUTRAL GROUND WHITE/BLACK TAP 1 15V TAP GREEN - DASHED LINES INDICATE ELECTRICAL CONTRACTOR WIRING - MULTIPLE LOADS CAN BE CONNECTED TO THE SAME OR DIFFERENT TAPS, DEPENDING ON DESIRED OUTPUT VOLTAGE, TO COMPENSATE FOR VARYING LOAD DISTANCES. PRIMARY INPUT The main Secondary Wiring is intended for shallow burial - less than 6 inches (152 mm) 2. CONNECT THE BLACK HOTWIRE INTO TERMINAL BLOCK LABELED "HOT". SUITABLE FOR INDOOR / OUTDOOR USE SUITABLE FOR USE WITH SUBMERSIBLE LUMINAIRES OR SUBEMERSIBLE PUMPS QOM-150 QOM-300 QOM-500 QOM-600 QOM-750 QOMD-2X150 QOMD-2X300 QOMD-150/300 LAMP WATTS 150W 300W 500W 600W 750W 300W 600W 450W PRI. LOAD 200VA 400VA 665VA 800VA 1000VA 400VA 800VA 600VA AMPS* 2 0 0 VA PV 4 0 0 VA PV 6 6 5 VA PV 8 0 0 VA PV 1 0 0 0 VA PV 4 0 0 VA PV 8 0 0 VA PV 6 0 0 VA PV * For Input Amps, Divide Primary Load VA by Primary Voltag WIRE TYPE PRI. WIRE COLOR For Supply connections use wire rated for at least 60C. NOTE: When multiple transformers are installed in one enclosure, please use the above diagram for each transformer. The terminal blocks and breakers are numbered along with their respective transformers. MODEL NUMBERS 1. CONNECT THE 230V OR 277V NEUTRAL WIRE INTO THE BLOCK LABELED TAP 1 OR TAP 2 DEPENDING ON INPUT VOLTAGE. ONLY USE ONE TAP. “WARNING - RISK OF FIRE. If installation requires running wire through a building structure, special wiring methods are needed. Contact a qualified electrician. * - USE SECONDARY TERMINAL BLOCKS FOR LOAD CONNECTIONS LANDSCAPE POWER SUPPLY 16HW “WARNING - RISK OF SHOCK. Install power unit 5 feet (1.5 m) or more from the pool or spa and 10 feet (3.05 m) or more from a fountain. Where the power unit is installed within 10 feet (3.05 m) of a pool or spa, connect unit to GFCI protected branch circuit.” L O A D * ( * ) CONNECT TO ANY TAP E247732 STEP 6 Install cover and tighten screw(s). © 2009 Q-Tran, Inc. TAP 2 GROUND STEP 5 The power supply is to be installed and serviced only by trained service personnel. SUITABLE FOR USE WITH LOW VOLTAGE LANDSCAPE LUMINAIRES / FITTINGS OR GREY L O A D SECONDARY TAPS - COMMON SIDE STEP 1 Install housing using the built-in support bracket for surface mounting. Remember that all Primary and Secondary wiring should be Class 1 per the National Electric Code. WIRING DIAGRAM HOT BLACK NEU (TAP 1) RED NEU (TAP 2) ORANGE GROUND GREEN BREAKER MINIMUM AWG 5A 14 60W 10A 14 120W 15A 14 180W 20A 12 240W 25A 10 300W Contact your local Distributor or Q-Tran for Q-Wire, Q-Click or proper Accessory Kit www.Q-Tran.com PH 203-367-8777 12V FX 203-367-8771