Data Center
Solutions Guide
Infrastructure Design in the
The data center has become a critical asset of today’s information-intensive enterprise, supporting all the applications
needed to maintain daily communication, productivity, and functionality. Designing and sustaining a data center capable
of supporting these applications is a considerable undertaking, and a properly designed infrastructure is key to
maximizing that investment both now and in the future.
Design Issues
Designing and implementing an infrastructure that maximizes data center management is vital to maintaining availability,
operational efficiency, and aesthetics while also supporting growth, advances in technology, regulatory changes, and the
increasing need for security. On the other hand, poor infrastructure design decisions can affect long-term reliability and
total cost of ownership.
Making some simple choices when
designing the infrastructure can result in
dramatic improvements for key data center
issues such as: Air Flow, Response Time,
Administration, Space Utilization, Security
and Aesthetics.
Increase in
Power Consumption
The increase in power density for
active data center equipment has driven
the cost of cooling and power consumption to a new level. Even with the improved efficiency and discipline of switching off idle equipment, and using more
energy-efficient servers and switches, heat
loads in a 42U cabinet have
increased 12½ times over the past six
years. And the best-case scenario has that
number rising another 44% over the next six years. In fact, some experts estimate a requirement of 30 to 50 kilowatts for
each cabinet or rack space!1 With higher-density cable bundles, an infrastructure design that helps manage airflow into
and out of a cabinet is increasingly critical to equipment performance and lifespan, and ultimately data service levels.
Cost of Downtime
Downtime is costly and unacceptable in today’s data center. Recent studies show that estimated losses for downtime can
run into the millions of dollars for many industries. With more than 50% of all data center infrastructure failures
resulting from maintenance or other administration activities2, the data center infrastructure must enable IT managers to
deploy equipment, complete reconfigurations, and respond to maintenance issues as quickly as possible.
2
Hubbell Premise Wiring • 14 Lord’s Hill Road • Stonington, CT 06378 • Tel: (860) 535-8326 • Fax: (860) 535-8328
Data Center
Floor Space Cost
The rising cost of environmentally controlled data center real estate, combined with the expense to cool the
active equipment, means that space utilization must be carefully considered and efficiently managed. Not only is it
important to maximize data center floor space utilization, but also the infrastructure must optimize rack space, minimize
connections, and increase cabling density.
Security
The protection of data and equipment in today’s information-intensive enterprise has called for an increase in both
logical and physical security. Not only do IT managers need to ensure that proper encryption and firewalls are in place,
but the physical infrastructure must also protect and secure connections and equipment. Infrastructure products including
sturdy, tamper-resistant enclosures and fault-resistant connections can go a long way in securing these critical assets.
Aesthetics
While data center availability is paramount, the data center must also showcase a company’s commitment to technology.
When designing the infrastructure, innovative cabling management solutions can greatly improve the overall look and
aesthetics of the data center, both at deployment and following future moves, adds, and changes. Aesthetics is also a
benefit from a design that minimizes cable congestion.
The Hubbell Committment
As a global manufacturer of structured cabling systems, enclosures, and accessories, Hubbell Premise Wiring can help IT
managers respond to the key data center issues of airflow, response time, administration, space utilization, security, and
aesthetics. Hubbell is dedicated to delivering product innovation, advanced technology, the highest quality, and customer
service excellence for the data center. To top it off, the Hubbell MISSION CRITICAL® program gives IT managers the
assurance of system success with a 25-year guarantee on the components, performance, and installation integrity of your
data center’s structured cabling infrastructure.
1. Brill, K. (2005) “2005-2010 Heat Density Trends in Data Processing, Computer Systems and Telecommunications Equipment” (Uptime Institute).
2. “Site Uptime® Procedures and Guidelines for Safely Performing Work in an Active Data Center”, CompuSite Engineering, Inc. and the Uptime Institute
(2007).
www.hubbell-premise.com
Call 1-800-626-0005
3
Airflow
The increasing array of active equipment designed into smaller packages results in more heat and
more cable congestion, which impedes airflow.
Impact
Lower operating costs, longer equipment life expectancy.
Design
Objectives
• Define air pathways.
• Eliminate airflow obstructions.
• Reduce cable bulk.
• Condense connection form factor.
Administration
The ability to locate equipment, cables, and connections at all times is critical in the dynamic data
center environment.
Impact
Lower operating costs.
Design
Objectives
• Utilize a structured identification system.
• Minimize infrastructure components.
• Defined cable pathways and accessibility.
Response Time
As the enterprise strives to be more competitive, the organization must be able to dynamically and
rapidly transform its communication and technology infrastructure for future growth.
Impact
Maximize uptime.
Design
Objectives
• Minimize number of system component parts.
• Factory-tested components.
• Plug and play connections.
• Maximum flexibility for moves, adds and changes (MACs).
Total Cost of Ownership
4
Hubbell Premise Wiring • 14 Lord’s Hill Road • Stonington, CT 06378 • Tel: (860) 535-8326 • Fax: (860) 535-8328
Security
Protection of mission critical data, adherence to regulatory requirements and defending against
unauthorized access to equipment are key requirements for today’s data center environment.
Impact
• Increased revenue - protection of proprietary information.
• Increased customer confidence.
Design
Objectives
• Control access to data center.
• Factory-sealed components.
• Limit physical access to network connections.
• Intrinsically secure media.
• Use fault-tolerant connections.
Space Utilization
Maximizing utilization of expensive data center real estate is a key to controlling operating
expenses.
Impact
Lower operating expense.
Design
Objectives
• Minimize number of connections.
• Maximize connection density.
• Maximize floor space utilization.
• Minimize cable pathway congestion.
• Maximize rack and cabinet utilization.
Aesthetics
The Data Center is a reflection of the proficiency and the capability of the enterprise.
Impact
Positive customer perception - internal pride.
Design
Objectives
• Covered cable management.
• Stylized equipment racks and cabinets.
• Minimize clutter and cable congestion.
Hubbell can help you minimize the Total Cost of Ownership of your data center operation by providing you with
solutions that exceed all of the design objectives. Minimize start-up costs, downtime and operating costs and
maximize long-term reliability. All under the protection of the Hubbell 25-year MISSION CRITICAL® Cabling
System Warranty.
www.hubbell-premise.com
Call 1-800-626-0005
5
MTP Plug and Play
•
12 strand fiber has much smaller profile than equivalent
UTP - removing a significant obstacle from air handling spaces.
Laser optimized
50 micron fiber
for 10GbE
applications.
•
•
Factory-sealed cassettes ensure secure connection.
Optical fiber is immune to signal tapping.
Reduces time to
prepare for new
servers by 50%.
•
Factory-terminated multimode and singlemode 12-fiber
fanouts reduce onsite installation time.
100% optically tested for reliable performance.
12-Fiber MTP building cables with pulling grip attached.
MTP keyed connector eliminates polarity questions.
•
•
•
Reduces cable
bulk and
improves airflow
in plenum
spaces, extending
equipment life.
Factory-terminated
and tested cable
assemblies increase
reliability and
minimize installation
expense.
6
•
High bandwidth fiber transmits more data per cable
for optimum use of cable pathways.
•
Reduced cable congestion makes it easier to identify
and trace ports and cables.
•
•
Fewer cables eliminate unsightly clutter.
Splicing connections concealed within cassette
enclosure.
OCLC62 MTP Cassette
Hubbell Premise Wiring • 14 Lord’s Hill Road • Stonington, CT 06378 • Tel: (860) 535-8326 • Fax: (860) 535-8328
y System
MTP Plug and Play System
MTP Plug and Play Cassettes
Connector Type
SC Duplex
SC Duplex
SC Duplex
SC Duplex
ST-style
ST-style
ST-style
LC Duplex
LC Duplex
LC Duplex
LC Duplex
LC Quad
MT-RJ
MT-RJ
Fiber Type
50μm
50μm, 10GbE
62.5μm
SM
50μm
62.5μm
SM
50μm
50μm, 10GbE
62.5μm
SM
50μm, 10GbE
50μm
62.5μm
Catalog No.
OCSC50
OCSC50G
OCSC62
OCSCSM
OCST50
OCST62
OCSTSM
OCLC50
OCLC50G
OCLC62
OCLCSM
OCLCQ50G
OCRJ50
OCRJ62
MTP to MTP 12-Fiber Cords with Pulling Grip
Fiber Type
Length
50μm
10m
50μm, 10GbE
10m
62.5μm
10m
SM
10m
50μm
25m
50μm, 10GbE
25m
62.5μm
25m
SM
25m
50μm
50m
50μm, 10GbE
50m
62.5μm
50m
SM
50m
50μm
100m
50μm, 10GbE
100m
62.5μm
100m
SM
100m
Custom MTP cords available upon request.
Catalog No.
FPCMTP5010
FPCMTP50G10
FPCMTP6210
FPCMTPS10
FPCMTP5025
FPCMTP50G25
FPCMTP6225
FPCMTPS25
FPCMTP5050
FPCMTP50G50
FPCMTP6250
FPCMTPS50
FPCMTP50100
FPCMTP50G100
FPCMTP62100
FPCMTPS100
Please consult the Hubbell Premise Wiring Full Line Catalog for the complete
fiber offering.
FPCMTP50G10 12-fiber
cord with pulling grip
Photo at left shows the MTP Plug and Play components OCLC62 MTP Cassette and FPCMTP50G10
12-Fiber Cord with Pulling Grip.
www.hubbell-premise.com
Call 1-800-626-0005
7
Fiber Connections
•
•
Laser optimized
50 micron fiber for
10GbE applications
extends life of
investment.
•
Optical fiber is immune to signal tapping.
•
2CLICK™ no epoxy, no polish connectors allow prompt
response if you require a connector change in the field.
Fiber adapter panels snap in and out of all enclosures
for easy customization and rapid change-outs.
•
Reduces cable bulk
and improves
airflow in plenum
spaces, extending
equipment life.
Factory-terminated
and tested cable
assemblies increase
reliability.
Smaller cross section of fiber cords and cables saves
valuable plenum and cabinet space
Optical fiber cables and cords do not carry electrical
energy and therefore, have no heat to dissipate.
•
High bandwidth fiber transmits more data per cable
for optimum use of cable pathways.
•
Individual channels labeled on all patch cords
from the factory.
•
Fewer cables eliminate unsightly clutter.
72-fiber LC Trunk Cable
8
Hubbell Premise Wiring • 14 Lord’s Hill Road • Stonington, CT 06378 • Tel: (860) 535-8326 • Fax: (860) 535-8328
Fiber Connections
2CLICK™ Pre-Polished LC Connectors
Description
Multimode, 50μm, 10G, 10-pk, Aqua Housing
Multimode, 62.5μm, 10-pk, Beige Housing
Singlemode, 10-pk, Blue Housing
2CLICK™ Pre-Polished SC Connectors
Description
Multimode, 50μm, 10G, 10-pk, Aqua Housing
Multimode, 62.5μm, 10-pk, Beige Housing
Singlemode, 10-pk, Blue Housing
Catalog No.
FCLC50GM10
FCLC62M10
FCLCSM10
Catalog No.
FCSC50GM10
FCSC62M10
FCSCSM10
FSP Loaded Adapter Panels - LC Duplex - Phosphor Bronze Sleeves - MM Applications
# Fibers # Adapters
12
6
12
6
Type
LC Duplex Beige
LC Duplex Aqua
Version
Standard
High-Density
Catalog No.
FSPLCDM6
FSPLCDM6AQ
FSP Loaded Adapter Panels - LC Quad - Phosphor Bronze Sleeves - MM Applications
# Fibers # Adapters
12
3
12
3
24
6
24
6
Type
LC Quad Beige
LC Quad Aqua
LC Quad Beige
LC Quad Aqua
Version
Standard
Standard
High-Density
High-Density
Catalog No.
FSPLCQM3
FSPLCQM3AQ
FSPLCQM6
FSPLCQM6AQ
FSP Loaded Adapter Panels - LC Duplex - Zirconia Sleeves - SM Applications
# Fibers # Adapters
12
6
Type
LC Duplex Blue
Version
Standard
Catalog No.
FSPLCDS6
FSP Loaded Adapter Panels - LC Quad - Zirconia Sleeves - SM Applications
# Fibers # Adapters
12
3
24
6
Type
LC Quad Blue
LC Quad Blue
Version
Standard
High-Density
Catalog No.
FSPLCQS3
FSPLCQS6
FSP Loaded Adapter Panels - SC Duplex - Phosphor Bronze Sleeves - MM Applications
# Fibers # Adapters
12
6
12
6
Type
SC Duplex Beige
SC Duplex Aqua
Version
Standard
Standard
Catalog No.
FSPSCBE6
FSPSCDM6AQ
FSP Loaded Adapter Panels - SC Duplex - Zirconia Sleeves - SM Applications
# Fibers # Adapters
12
6
Type
SC Duplex Blue
Version
High-Density
FTR Tray - FSP Adapter Panel Version
Capacity
3 FSP adapter panels
6 FSP adapter panels
12 FSP adapter panels
15 FSP adapter panels
Rack Units
1
2
3
4
Catalog No.
FSPSCDS6
Catalog No.
FTR175SP
FTR350SP36
FTR525SP
FTR700SP
FCR Rack Mount Enclosures
Accepts
Height
Rack Units
Catalog No.
6 FSP series adapter panels
3.50” (89)
2
FCR350SP36R
9 FSP series adapter panels
3.50” (89)
2
FCR350SP54R
12 FSP series adapter panels
5.25” (133)
3
FCR525SPR
15 FSP series adapter panels
7.00” (178)
4
FCR700SP
Other adapter colors are available. Pigtails, Patch Cords and Multifiber trunk cables are available in
various cable styles. Please consult our Full Line Catalog for the complete fiber offering.
Photo at left shows a Make-to-Order 72-fiber LC Trunk Cable and Single-Fiber Pigtails.
www.hubbell-premise.com
Call 1-800-626-0005
9
Ascent 10GbE System
Supports a
maximum
bandwidth
beyond 500MHz,
extending life of
investment.
Cat 6A UTP
delivers PoE more
effectively than
5e, reducing
utility expense
by more than 50%.
•
Designed specifically for 10GbE applications
providing a solid foundation for critical data
intensive applications.
•
Termination time reduced by 75% through the use
of quick lace design and the TX4PP 1-Punch tool.
•
Angled UDX panels eliminate horizontal cable
management allowing for maximized rack space
utilization.
High density 36- and 48-port UDX panels
maximize the total amount of jacks for each
rack unit.
•
•
•
•
•
10
PC6AGY03
Patch Cord
All NEXTSPEED® Ascent 10GbE components have
provisions for labeling for easy administration.
Hubbell complements each product with
standardized labels and software to simplify the
task of identification.
10GbE bandwidth per cable minimizes cable
count, improving appearance.
Stylized panel aesthetics.
HXJ6AGY
Jacks
Hubbell Premise Wiring • 14 Lord’s Hill Road • Stonington, CT 06378 • Tel: (860) 535-8326 • Fax: (860) 535-8328
m
NEXTSPEED® Ascent 10GbE System
NEXTSPEED® Ascent Patch Panels, 10GbE
Description
24-port, 1 Rack U, Black
48-port, 2 Rack U, Black
96-port, 4 Rack U, Black
24-port, 1 Rack U, Silver
48-port, 2 Rack U, Silver
96-port, 4 Rack U, Silver
P6A24US
Wiring
Universal Wiring
Universal Wiring
Universal Wiring
Universal Wiring
Universal Wiring
Universal Wiring
Catalog No.
P6A24U
P6A48U
P6A96U
P6A24US
P6A48US
P6A96US
NEXTSPEED® Ascent Patch Cords, Cat 6A
Description
Wiring
Catalog No.
Patch Cord, Stranded Cat 6A
T568B
PC6AXXXX
XX=Color: BK=Black, B=Blue, DG=Dark Gray, GN=Green, GY=Gray, OR=Orange,
Y=Yellow.
XX = Length: ‘03’ = 3’, ‘05’ = 5’, ‘07’ = 7’, 10’ = 10’, ‘15’ = 15’, ‘20’ = 20‘.
NEXTSPEED® Ascent UTP Cable, 10GbE/Cat 6A
Description
Type
Catalog No.
UTP Cable, Category 6A, Solid
Plenum
C6ASPXX
UTP Cable, Category 6A, Solid
Riser
C6ASRXX
XX=Color: B=Blue, GN=Green, GY=Gray, OR=Orange, W=White, Y=Yellow.
NEXTSPEED® Ascent 6-110 Block Kit, 10GbE/Cat 6A
Description
64-Pair Kit with legs*
64-Pair Kit w/o legs*
192-Pair Kit with legs*
* 6-110, 4-pair connecting clips.
P6A48US
Type
Universal
Universal
Universal
Keystone Jack Panels (Unloaded)
Style
High-Density
Multimedia
Angled
Height
1U (1.75”)
2U (3.50”)
2U (3.50”)
Ports
48
48
48
Catalog No.
6110FTK64WL
6110FTK64NL
6110FTK192WL
Color
Black
Black
Black
Catalog No.
UDX48E1U
UDX48E
UDXA48
XCELERATOR™ Modular Jacks, 10GbE
Description
Wiring
Catalog No.
XCELERATOR™ Jack, 10GbE
1
HXJ6AXX
XX=Color: AL=Almond, BK=Black, B=Blue, EI=Electric Ivory, GY=Gray, GN=Green, LA=Light
Almond, OW=Office White, OR=Orange, P=Purple, R=Red, TI=Telco Ivory W=White,
Y=Yellow.
Add ‘25’ to the end of the Catalog No. for 25-Pack option.
6110FTK64WL
C6ASPB Cable
www.hubbell-premise.com
Please consult the Hubbell Premise Wiring Full Line Catalog for the complete
UTP offering.
Photo shown at left includes the components of Hubbell’s Ascent 10GbE System (P6A24US and
P6A48US Patch Panels, HXJ6AGY Jacks, 6110FTK64WL Punch Down Blocks, PCGAGY03 Patch Cords
and C6ASPB Cable).
Call 1-800-626-0005
11
Shielded 10GbE Syst
Elimination of
AXT and EMI,
minimizing
trouble-shooting
and downtime.
•
10GbE FTP cable’s reduced OD optimizes airflow
throughout the infrastructure.
•
Shielding protects against signal tapping and EMI.
•
The NEXTSPEED® shielded 10GbE enhanced
performance FTP cabling system is designed
specifically for 10GbE applications and provides
a solid foundation for critical data intensive applications.
Tool-less jack termination reduces FTP termination under
2 minutes.
•
Supports a
maximum
bandwidth
beyond 500MHz,
extending life of
investment.
•
PSJ24 UDX panels maximize the total amount of shielded
jacks for 1 rack unit.
•
All NEXTSPEED® shielded 10GbE components have
provisions for labeling for easy administration.
SJ62B Jacks
•
•
12
One-piece shielded jack construction.
Smaller cable diameter reduces cable congestion.
PS603GY
Patch Cord
Hubbell Premise Wiring • 14 Lord’s Hill Road • Stonington, CT 06378 • Tel: (860) 535-8326 • Fax: (860) 535-8328
tem
NEXTSPEED® Shielded 10GbE System
NEXTSPEED® Shielded Jacks, Category 6/10GbE
Description
Shielded Jack, Category 6/10GbE, 2-pack
Shielded Jack, Category 6/10GbE, 24-pack
B-Wired Catalog No.
SJ62B
SJ624B
NEXTSPEED® Shielded Patch Panels, Unloaded
Description
Shielded Patch Panel, 24-port, 1U, Gray
Wiring
Universal
A-Wired Catalog No.
SJ62A
SJ624A
Catalog No.
PSJ24
NEXTSPEED® Shielded Patch Cords, Category 6/10GbE
Description
Wiring
Catalog No.
Shielded Patch Cord, Stranded Patch Cable
T568B
PS6XXXX
XX = Length: 03 = 3’, 05 = 5’, 07 = 7’, 10 = 10’, 15 = 15’, 20 = 20‘, 25 = 25’.
XX = Color: B=Blue, GY=Gray.
NEXTSPEED® FTP Cable, Category 6/10GbE
C6FTPSB
Cable
Description
Type
FTP Cable, Category 6A, Solid
Plenum
FTP Cable, Category 6A, Solid
Riser
XX=Color, B=Blue, GY=Gray, PK=Pink, W=White.
Catalog No.
C6FTPSPXX
C6FTPSRXX
Please consult the Hubbell Premise Wiring Full Line Catalog for the complete
shielded offering.
PSJ24
Photo at left shows components of the Hubbell Shielded 10GbE System including PSJ24 Panel, SJ62B
Jacks, PS603GY Patch Cords and C6FTPSB Cable.
www.hubbell-premise.com
Call 1-800-626-0005
13
25-Pair Gigabit Ass
•
•
Substantially
reduces time to
prepare for new
servers.
Reduces cable bulk
and improves
airflow in plenum
spaces.
•
25-pair cable assemblies fasten to the rear of
panel securing the connection onto the panel
eliminating errant terminations.
•
•
Third party verification to IEEE 802.3ab.
Create a “plug and play” connection within the data center
easily interfacing between switches (RJ21X) or standard
patch panels (RJ45).
Bandwidth beyond 100MHz.
•
Factory-terminated
and tested cable
assemblies
increase reliability.
14
25 pair cable much smaller profile than equivalent
6-cable bundle of 4 pair UTP.
Frees up valuable space in the cabinet and in the
floor for maximum airflow.
•
•
High-density configuration optimizes valuable rack space.
Condensed cable size results in smaller cable channels,
minimizing floor space footprint.
•
Much easier to track and manage a single 25-pair
cable versus 6 4-pair UTP cables.
•
•
Fewer cables eliminate unsightly clutter.
Condense cable channel congestion.
Hubbell Premise Wiring • 14 Lord’s Hill Road • Stonington, CT 06378 • Tel: (860) 535-8326 • Fax: (860) 535-8328
emblies
25-Pair Gigabit Assemblies
1000BASE-T Patch Panel
Delivery:
Finish:
Ports
1 1000BASE-T patch panel, 4 mounting screws, 4 cable assembly screws.
Durable, black powder coat.
Height
Width
Depth
Connectors
Catalog No.
24
1.75” (45)
19” (483)
1.2” (31)
Female
48
3.50” (89)
19” (483)
1.2” (31)
Female
PG24
PG48
25-Pair Cable Assemblies
Delivery: 1 cable assembly supplied with mounting screws, male-to-male connectors and a choice
of various connector configurations.
Connector Angles
Gender
Catalog No.
180° to 90°
Male-to-Male
525G21XXE*
180° to 180°
525G22XXE*
Male-to-Male
110° to 110°
Male-to-Male
525G33XXME*
* XX denotes Length in feet: 05=5 feet, 10=10 feet, 15=15 feet.
Please consult the Hubbell Premise Wiring Full Line Catalog for the complete
high pair count offering.
PG48
Patch Panel
525G2210E
25-pair Gigabit
Cable Assembly
www.hubbell-premise.com
Photo at left shows components of the Hubbell 25-Pair Gigabit Cable Assemblies including the PG48
Patch Panel with the 525G2210E 25-Pair Cable Assembly.
Call 1-800-626-0005
15
Vertical Patch Panel
Eliminates 1000’
of cable in each
cabinet when
fully loaded.
•
Places data and KVM ports at each rack unit
allowing use of short connecting cables and
eliminating cable that would otherwise restrict
airflow.
•
Accommodates primary, secondary and tertiary
data ports at each rack position.
•
Options supporting 1GbE, 10GbE and optical fiber
ensuring plenty of bandwidth.
•
By moving data connections along side of cabinet,
2 rack spaces are freed for the use of additional
equipment.
•
Much easier to identify and trace ports and cables.
•
Double door provides open access to cable,
conceals large cable channel.
Concealed horizontal cable and short jumper
connections result in nice neat installations.
Stylized look enhances appearance of any
computer room.
Substantially
reduces time to
prepare for new
servers.
Modular construction
provides migration
path and scalability.
•
•
16
Hubbell Premise Wiring • 14 Lord’s Hill Road • Stonington, CT 06378 • Tel: (860) 535-8326 • Fax: (860) 535-8328
Vertical Patch Panels and Data Modules
Hubbell Vertical Patch
Panel Catalog No. VPH
Vertical Patch Panel
Delivery: 1 75” section, 2 Rolls of 10 VELCRO® brand ONE-WRAP® cable ties, 1 Kit
installation hardware, 8 #12 attachment screws.
Description
No. of Data Module Locations
15
iFRAME® Vertical Patch Panel for
Hubbell iFRAME® Server Cabinet
Data Modules
Hubbell 10GbE Jacks
mounted in Vertical
Patch Panel.
Catalog No.
VPH
Data Module
1GbE Data Module
(25-pair)
# Ports/module
6 port
module
Panel Use
Fits into Vertical Patch Panel Data Module
opening to terminate 25 pair 1GbE cable
assembly.
Catalog No.
VPP1G
Blank Covers
(10-pack)
0
Covers unused Data Module Openings
VPMB
iSTATION™
Module Bezel
8
Each bezel (VPMI) accepts 4 two-port
modules (IM2K1GY), which snap into
VPMI for data applications where
individual jacks are desired
(color coding, 10GbE).
VPMI
iSTATION™ Module, 2
2-port, gray
Each module accepts 2 HXJ jacks or
AV inserts and snaps into VPMI.
IM2K1GY
10GbE (55m)
Module, 6-port
Fits into Vertical Patch Panel data
module opening for use with Cat 6 UTP
(10GbE - TSB-155)
VPPC6
6
VELCRO® and ONE-WRAP® are registered trademarks of Velcro Industries B.V.
Please consult the Hubbell Premise Wiring Full Line Catalog for the complete
Vertical Patch Panel offering.
Photo at left shows the VPH vertical patch panel connecting one-to-one to servers, minimizing patch
cord cost and air blockage.
www.hubbell-premise.com
Call 1-800-626-0005
17
Server Cabinet
•
•
•
IN-FRAME design
protects investment
by allowing frame
depth to be
increased in the field.
•
•
3-Point door locking system.
Optional locks for side covers.
•
Cable pathways are open facilitating movement and
additions of servers.
Rack positions are identified on all four uprights aiding
the installation of new gear.
Cable management spools snap into place.
•
Optimizes cooling,
extending life of
active equipment.
IN-FRAME design optimizes airflow by creating
designated cable pathways away from center of
cabinet.
Designed for HOT AISLE/COLD AISLE cooling.
Mounting rails fasten directly to frame preventing
airflow “slippage” around equipment.
•
•
Optional split rails kit maximizes cabinet utilization by
accommodating servers and switchgear in one cabinet.
•
Cable management spools with label fields to
identify bundles of cable.
Unobscured cable pathways simplify tracing
cables.
H1KT
Top Kit
Simplifies adding and
moving servers.
•
•
•
18
Stylized look enhances appearance of any
computer room.
IN-FRAME design facilitates consistent
cabinet ganging.
2-H1E80E
Hubbell Premise Wiring • 14 Lord’s Hill Road • Stonington, CT 06378 • Tel: (860) 535-8326 • Fax: (860) 535-8328
Server Cabinets and Accessories
Server Cabinet
Delivery:
1 Frame
2 Perforated doors, center opening
4 19" Mounting rails (square holes 2 Side panels, flush
with M6 cage nuts)
1 Kit of 20 M6 cage nuts, screws and washers
Finish: Durable powder coat, black.
Description
Height Width Depth
Catalog No.
Server Cabinet, 80"H
80"
24"
42"
H1E80E
Server Cabinet, 80"H, without sides
80"
24"
42"
H1E80EX
Server Cabinet, 80"H
80"
24"
36"
H1E80ED
Server Cabinet, 80"H, without sides
80"
24"
36"
H1E80EDX
Fan Tray
Delivery: 1 fan tray assembly, wired, 1 kit mounting hardware.
Description
Catalog No.
Fan kit, 114 CFM, 120 VAC, 60 Hz, 36 dBA
HWKF120
HWKF230
H1KB
Fan kit, 114 CFM, 230 VAC, 50 Hz, 36 dBA
Blank plate with 4” fan/PVC conduit cut-out
Telescopic Equipment Shelf
Dimensions: 16.65”W x 29.2”D. Load capacity: 200 lbs.
Delivery: 1 shelf pre-assembled with telescopic slides, 2 rear mounting brackets and 1 kit mounting
hardware.
Color
Catalog. No.
Black
CKTSD
Stationary Equipment Shelf
Dimensions: 17.69”W x 29.29”D.
Delivery: 1 shelf, washers, cage nuts, (4) #12-24 mounting screws, washers, cage nuts.
Color
Catalog. No.
Black
CKSSD
Top Plate
Includes 1 Mounting Plate, 4 snap in spools, 1 kit mounting hardware.
Catalog No.
H1KT
Please consult the Hubbell Premise Wiring Full Line Catalog for the complete
Server Cabinet offering.
Photo shown at left shows two H1E80E Server Cabinets with H1KT Cable Management Top Kits.
www.hubbell-premise.com
Call 1-800-626-0005
19
Network Cabinet
•
IN-FRAME design optimizes airflow by creating designated
cable pathways away from center of cabinet.
Can be used in front to rear, side to side, and bottom to top
airflow configurations.
Optional top keeps cable clear of fan tray exhaust.
•
•
3-Point door locking system.
Optional locks for side covers.
•
Cable pathways are open facilitating movement and
additions of servers.
Rack positions are identified on all four uprights aiding the
installation of new gear.
Cable management spools snap into place.
Optional split rails kit maximizes cabinet utilization by
accommodating servers and switchgear in one cabinet.
•
•
IN-FRAME design
protects investment
by allowing frame
depth to be
increased in the field.
•
Optimizes cooling,
extending life of
active equipment.
•
•
Superb cable
management
reduces
administration time
and operating
expense.
•
Enhanced cable management features allow cable
storage within the cabinet.
•
•
Much easier to identify and trace ports and cables.
Cable management spools with label fields to
identify bundles of cable.
Unobscured cable pathways simplify tracing
cables.
•
•
•
Stylized look enhances appearance of any
computer room.
IN-FRAME design manages and conceals
cable bundle.
H1N84E
20
Hubbell Premise Wiring • 14 Lord’s Hill Road • Stonington, CT 06378 • Tel: (860) 535-8326 • Fax: (860) 535-8328
H1KX4
Networking Cabinet and Accessories
Networking Cabinet
Delivery:
1 Frame, 2 Perforated doors, left hinging, 4-19” Mounting rails (#12-24), 2 Side panels,
3” wide for cable management, 1 Kit of 20 dog-nosed screws, #12-24 x 5/8, 16 Cable management
spools, snap in
Finish: Durable powder coat, black.
Networking Cabinet with Side Covers
Rack Units
43
45
Overall
Height
80.7”
84.2”
Overall
Width
30”
30”
Networking Cabinet without Side Covers
Rack Units
43
45
Movable snap in spools (Cat. # ICKSS) in
top to route cable.
Overall
Height
80.7”
84.2”
Overall
Width
30”
30”
Catalog No.
32” Depth
Catalog No.
36” Depth
H1N80E
H1N84E
H1N80ED
H1N84ED
Catalog No.
32” Depth
Catalog No.
36” Depth
H1N80X
H1N84X
H1N80XD
H1N84XD
Vertical Cable Management Options:
• Snap in Spools (ICKSS).
• Vertical Cable Management Rings
(HC26VR2).
• NEXTFRAME® Vertical Channels
(i.e., VS76H, VS76, VS73) - for use without side covers.
• Internal Vertical Organizer - for use with 3” side covers.
(H1KV80, H1KV84).
• Concealed by 3” Side Cover.
Cable entry with integrated bend relief.
Please consult Hubbell Premise Wiring Full Line Catalog for the complete
Premise Cabinet offering.
Photo at left shows an H1N84E Networking Cabinet and some of the cable management features of
its IN-FRAME design.
Unobstructed vertical cable pathways far
forward and concealed.
www.hubbell-premise.com
Call 1-800-626-0005
21
Column System
Increase usable rack
space per square
foot of floor space
by more than 15%.
Installs in half the
time of a traditional
rack.
•
Open design removes all barriers to forced and
convective airflow.
•
Maximum coverage of exposed cables
enhances security.
•
Cable pathways are open facilitating movement
and additions of servers.
Top ladder pieces cut to length and pre-drilled for
4” square work boxes at factory.
Cable management spools snap into place.
•
•
•
Durable components
designed to last
the life of the
cable plant.
•
•
•
•
•
•
22
Columns mount on 2’ pitch to align with floor
and ceiling grids.
1,400 lb. load capacity and 100% utilization of
rack space maximizes equipment density per
square foot.
Cable management spools with label fields to
identify bundles of cable.
Un-obscured cable pathways simplify tracing
cables much easier to identify and trace ports
and cables.
80% reduction in parts results in dramatic
reduction in number of brackets resulting in clean
uncluttered appearance*.
Double hinging covers project image of quality.
Stylized look enhances appearance of any
computer room.
* Compared to traditional relay rack with accessories.
Hubbell Premise Wiring • 14 Lord’s Hill Road • Stonington, CT 06378 • Tel: (860) 535-8326 • Fax: (860) 535-8328
4-IS7 and 3-ICKL mounted on top
iFRAME® Columns
Delivery:
1 iFRAME® column weldment, 1 Bottom alignment installation aid and floor template, 1 iFRAME® top
plate, 1 Full height front cover with dual-acting hinges*, 4 Heavy-duty floor anchor washers, 4 anchors,
4 shims, 20-#12-24 x 5/8” dog point machine screws or M6 hardware for IS7M6, 4 Gates, 4” (ref.
Catalog No. VCG4) and washers, 12 Snap in place cable routing spools, 1 Kit assembly hardware.
* Not included in IS7E.
For use in Applications:
Rack Units Height
Catalog No.
Without raised floor
45
7’
IS7
Without raised floor
19
3’
IS3
Raised floor up to 12” high
45
8’
IS7RF
When using M6 cage nuts
45
7’
IS7M6
Raised floor up to 12” high using M6 cage nuts
45
8.5’
IS7RFM6
Raised floor up to 18” high
45
8’
IS7RF18
As the rear columns in 4-post applications
45
7’
IS7E
NOTE: Two columns must be ordered for the first rack in a line. Only one column needs to be ordered for
each additional rack.
iFRAME® Top Ladder
Delivery: 1 iFRAME® 12” wide x 2’ top ladder with integrated waterfalls; pre drilled for 4” workbox, 1 kit
assembly hardware.
Finish: Durable black powder coat.
Catalog No.
ICKL
Cable Management Spools
Top plate (included
with each column)
aligns tops of
columns and
mounting for
ladder rack.
Delivery: Package of 50 spools and screws, 3½”, black.
Catalog No.
ICKSS
Power Strip Mounting Brackets
Delivery: 1 pair of brackets and hardware for mounting one Hubbell 66” power strip.
Catalog No.
ICKPM
Please consult the Hubbell Premise Wiring Full Line Catalog for the complete
Cable Management offering.
IS7 with cable
management
door open
www.hubbell-premise.com
IS7 with cable
management
door closed
Photo at left shows four IS7 7-foot iFRAME Columns in use.
Call 1-800-626-0005
23
Cable Management
Durable components
designed to last
the life of the
cable plant.
Maximize cable
transmission
performance.
•
Open design removes all barriers to forced and
convective airflow.
•
Maximum coverage of exposed cables
enhances security.
•
Organizers designed with rounded components
to reduce the risk of cold flow and cable kinks
to optimize transmission performance.
Cable pathways are easily and completely
open facilitating movement and additions of
servers.
•
•
Modular components can be field configured to
meet the unique needs of each application.
•
Cable management spools with label fields to
identify bundles of cable.
Much easier to identify and trace ports and cables.
•
•
24
Un-obscured cable pathways simplify tracing
cables.
Hubbell Premise Wiring • 14 Lord’s Hill Road • Stonington, CT 06378 • Tel: (860) 535-8326 • Fax: (860) 535-8328
t
CS1976
NEXTFRAME® Cable Management
NEXTFRAME® 19” Equipment Rack with Z Channels, 6”W
Delivery: 1 Rack, 7’H (HPW84RR19) and 2 vertical organizers (VS76H/VS76)
Finish: Durable black powder coat.
Rack Height
Rack Units
Finish
Cover Style
Catalog No.
7’ (2134)
45
Black
Hinged
CS1976H
7’ (2134)
45
Black
Clip on
CS1976
NEXTFRAME® 19” Duct Style Horizontal Organizers
Delivery: 1 organizer, 4 #12-24x5/8” dog-nosed screws and Nylon washers.
Panel Height Rack Units Front Ring Depth
Rear Ring Depth
Catalog No.
1.75”
1U
3.5”
HC119CE3H
3.50”
2U
3.5”
HC219CE3N
3.50”
2U
3.5”
4.6”
HC219CC3N
5.25”
3U
3.5”
HC319CE3N
Other NEXTFRAME® Components
•
•
•
•
Ladder Rack
Center Rack
Velcro® Cable Ties
Wall Mount Racks and Brackets
VELCRO® is a registered trademark of Velcro Industries B.V.
Please consult the Hubbell Premise Wiring Full Line Catalog for the complete
Horizontal Cable Management offering.
Photo at left shows the CS1976 19” Equipment Rack with 6” Wide Z-Channels and HC219CE3N DuctStyle Horizontal Organizers.
www.hubbell-premise.com
Call 1-800-626-0005
25
TWIST-LOCK® Power Devices an
Maximize up-time
by preventing
unintentional
disconnects.
•
Power drops from above remove obstacles
from airflow in plenum space.
•
•
Prevents unintentional disconnect.
Powerful, offsetting cord grips clamp on individual
conductors and outer cord jacket to prevent strain
on terminals.
Ribbed nylon housing is impact and chemical
resistant.
•
•
Flexible connections
allow for easy
reconfiguration.
•
•
Highly engineered
materials maximize
connection reliability
at all temperatures.
•
No need to install a
rigid power supply
infrastructure.
•
•
NEMA locking configurations for easy disconnect
when repositioning data center equipment.
KELLEMS® strain relief grips prevent conductor
pulling, delivering a secure electrical
connection.
Flexible cord connections allow equipment
to be powered without a rigid infrastructure
to work around.
KELLEMS® grips support flexible cable, eliminating
the need for rigid wire management systems.
Amperage and voltage indications are clearly
marked on the device for easy identification.
Individually molded face for each blade
configuration keeps debris out of plug interior.
• Integral dust shield.
• Tough, ribbed Nylon housing for secure gripping.
26
Hubbell Wiring Device-Kellems • 185 Plains Road • Milford, CT 06461-2420 • Fax: (800) 255-1031
d Kellems Grips
®
TWIST-LOCK® Devices
2-Pole/3-Wire
TWIST-LOCK® Devices
3-Pole/4-Wire
Connector Bodies
Connector Bodies
Amps
KELLEMS® Dustight Strain Relief Grip.
Voltage
NEMA
Catalog No.
15
125V
L5-15R
20
125V
L5-20R
20
250V
L6-20R
30
250V
L6-30R
HBL4729C
HBL2313
HBL2323
HBL2623
Plugs
Amps
TWIST-LOCK® Plug and
Connector Body.
Voltage
NEMA
Catalog No.
125V
125V
250V
250V
L5-15P
L5-20P
L6-20P
L6-30P
HBL4720C
HBL2311
HBL2321
HBL2621
Voltage
NEMA
Catalog No.
125V
125V
250V
250V
L5-15R
L5-20R
L6-20R
L6-30R
HBL4700
HBL2310
HBL2320
HBL2620
15
20
20
30
Receptacles
Amps
15
20
20
30
Amps
20
30
Voltage
NEMA
Catalog No.
3Ø480V
3Ø480V
L6-20R
L6-30R
HBL2433
HBL2733
Voltage
NEMA
Catalog No.
3Ø480V
3Ø480V
L6-20P
L6-30P
HBL2431
HBL2731
Voltage
NEMA
Catalog No.
3Ø480V
3Ø480V
L6-20R
L6-30R
HBL2430
HBL2730
Plugs
Amps
20
30
Receptacles
Amps
20
30
KELLEMS® Dustight Strain Relief Grips
Non-Insulated - Wide Range Strain Relief
Cable Diameter
Thread Size
Range Inches (cm)
N.P.T. Inches
Mesh Length @
Nom. Dia. Inches (cm)
.54”-.73”
(1.37-1.85)
¾”
6½” (16.51)
.73”-.97”
(1.85-2.46)
1”
7” (17.78)
.97”-1.25” (2.46-3.17)
1¼”
9” (22.86)
.73”-.97”
PG29
7” (17.78)
073031203
073031204
073031205
073PG291204
Insulated - Wide Range Strain Relief
Cable Diameter
Thread Size
Range Inches (cm)
Inches
Mesh Length @
Nom. Dia. Inches (cm)
Catalog No.
.54”-.73”
(1.37-1.85)
¾” N.P.S.
6½” (16.51)
.73”-.97”
(1.85-2.46)
1” N.P.S.
7” (17.78)
(1.85-2.46)
.97”-1.25” (2.46-3.17)
1¼” N.P.S.
9” (22.86)
1.25”-1.5” (3.17-3.81)
1½” N.P.T.
11¾” (29.84)
1.50”-1.70” (3.81-4.32)
2” N.P.T.
13¼” (33.65)
Catalog No.
073031209
073031210
073031211
073031212
073031213
Please consult the Wiring Device-Kellems Full Line Catalog for our complete offering
of TWIST-LOCK® Power Devices and Pulling and Support Grips.
Photo at left shows a server cabinet connected to power with Hubbell TWIST-LOCK® Connector Cord
Drops suspended using KELLEMS® Grips.
www.hubbell-wiring.com
Call (800) 288-6000
27
IEC Pin and Sleeve High Power
3-Phase power
optimizes use of
site power
distribution unit.
•
3-phase power cuts down cable bulk in
plenum spaces.
•
•
•
Shrouding - pins are recessed for user safety and protection against abuse.
Solid Pins - dependable solid brass for longer life and reliable electrical contact.
Locking ring on plug prevents unintentional disconnect when mounted with receptacle
or connector.
Patented opening on plug shroud accommodates lock shackle to comply with OSHA
lockout/tagout requirements.
•
•
Dependable
construction for
longer life, reliable
contact and less
downtime.
•
•
•
3-phase power optimizes circuit breaker space on
Power Distribution Unit breaker panel.
Tapered housings and ergonomic design eliminate
bulky connections.
•
Ratings and certifications are molded into housing
and devices are color-coded by voltage rating
for easy identification.
•
Pin and Sleeve high power devices eliminate clutter
and present a clean, orderly appearance.
Insulated, non-metallic housing prevents marring
of surfaces.
•
28
IEC Pin and Sleeve devices provide convenient
portable power and fast plug and play connections.
Fast, secure connections.
HBL430C7W
Connector Body
Hubbell Wiring Device-Kellems • 185 Plains Road • Milford, CT 06461-2420 • Fax: (800) 255-1031
r Connections
IEC Watertight Pin and Sleeve Devices
Connector Bodies
Amps
Voltage
Catalog No.
30
3P/4W
3Ø480V
30
3P/4W
3Ø250V
30
3P/4W
125/250
60
3P/4W
3Ø480V
60
3P/4W
3Ø250V
60
3P/4W
125V/250V
HBL430C7W
HBL430C9W
HBL430C12W
HBL460C7W
HBL460C9W
HBL460C12W
Plugs
Amps
Poles/Wires
Voltage
Catalog No.
30
Poles/Wires
3P/4W
3Ø480V
30
3P/4W
3Ø250V
30
3P/4W
125/250
60
3P/4W
3Ø480V
60
3P/4W
3Ø250V
60
3P/4W
125V/250V
HBL430P7W
HBL430P9W
HBL430P12W
HBL460C7W
HBL460C9W
HBL460C12W
Voltage
Catalog No.
3Ø480V
3Ø250V
125/250
3Ø480V
3Ø250V
125V/250V
HBL430R7W
HBL430R9W
HBL430R12W
HBL460R7W
HBL460R9W
HBL460R12W
Receptacles
Amps
30
30
30
60
60
60
Poles/Wires
3P/4W
3P/4W
3P/4W
3P/4W
3P/4W
3P/4W
Please consult the Wiring Device-KELLEMS® Full Line Catalog for the complete
Wiring Device Pin and Sleeve offering.
HBL430P7W
Plug
Photo at left shows Hubbell HBL430P7W Plug and HBL430C7W Connector Body.
www.hubbell-wiring.com
Call (800) 288-6000
29
Power Distribution
•
•
3-phase power
optimizes
use of site power
distribution unit
breaker panel.
•
TWIST-LOCK® plugs prevent accidental
disconnection of power cords.
•
Densely located receptacles ensure that there is
always power available for new equipment.
•
Locating receptacles at each rack position
minimizes length of power cord and eliminates
clutter.
•
Color coded receptacles are a quick and easy
way to identify phases at a glance.
Cable management spools with label fields to
identify bundles of cable.
Improved airflow
extends life of
active equipment.
Simplifying load
balancing
reduces energy
costs.
•
•
30
3-phase power delivery reduces cable bulk below
the raised floor eliminating obstacles to airflow.
Locating receptacles at each rack position
minimizes length of power cord bulk and
eliminates obstacles to airflow.
Unobscured cable pathways simplify tracing
cables.
Hubbell Premise Wiring • 14 Lord’s Hill Road • Stonington, CT 06378 • Tel: (860) 535-8326 • Fax: (860) 535-8328
Power Distribution
Horizontal Power Strips
Delivery: 1 power strip and 1 kit mounting hardware.
Finish: Durable black powder coat.
Electrical
Specification
Outlets Front
Outlets Rear
15A/120V
0
10
15A/120V
0
10
15A/120V
4
4
20A/120V
0
10
20/16A, 120/250V
10
0
15A/120V
0
6
20A/120V
0
10
Catalog Number
HPWPWR
MCCPSS19
MCCPSS19TS
PR10120
PR10720*
PR0615
PR1020
PR0360**
60A/250V
0
3
* PR10720 includes an IEC 320 (C-20) inlet for power input. Vertical mount brackets are also included.
** PR0360 features 10’ cable with IEC 60A 2P/3W plug.
Vertical Power Strips
Delivery: 1 power strip and 1 kit mounting hardware.
Finish: Durable black powder coat.
Electrical Specification
Outlets
Number of Circuits
15A/120V
10
1
20A/120V
10
1
15A/120V
20
1
20A/120V
20
1
20A/120V
20
1
30A/120V
20
1
20/16A /circuit 120V
20
2
20/16A-120/250V
20
1
30/24A-250V
24
1
Catalog Number
PR104
PR10420
PR206
PR20620
PR20820DRTL
PR20830
PR20820A*
PR20820I**
PR24
PR40Z120***
120V
40
6
* PR20820A features (2) 20A circuits each fed by 10ft. cable with NEMA 5-20 plug.
** PR20820I includes an IEC 320 (C-20) inlet for power input.
*** Full length mounting bracket included.
Please consult the Hubbell Premise Wiring Full Line Catalog for the complete
Power offering.
Photo at left shows a PR40Z120 40-Outlet Power Strip with 3Ø input connecting one-to-one with servers using
1-foot power cords with HBL5266C plugs.
www.hubbell-premise.com
Call 1-800-626-0005
31
Empower Your Enterprise With an
Intelligent Infrastructure Solution.
High Performance Copper Systems
High Performance Fiber Connectivity
Power Infrastructure Solutions
Data Center Infrastructure
Zone Cabling Systems
Telecommunications Room Infrastructure
Converged Workstation Outlets
Delivery Systems
Harsh Environments
Wiring Devices
KELLEMS® Grips
RoHS
Hubbell Premise Wiring
Hubbell Wiring Device-Kellems
14 Lord’s Hill Road • Stonington, CT 06378-0901
(860) 535-8326 • 800-626-0005 • Fax: (860) 535-8328
Internet site: http://www.hubbell-premise.com
185 Plains Road • Milford, CT 06461-2420
(203) 882-4800 • (800) 288-6000 • Fax: (800) 255-1031
Internet site: http://www.hubbell-wiring.com
HUBBELL INCORPORATED (Delaware)
HUBBELL INCORPORATED (Delaware)
B-DC1 02/08
Worldwide Locations
Hubbell
Hubbell
Hubbell
Hubbell
Hubbell
Hubbell
Hubbell
Premise Wiring, Asia Pacific
Canada Inc.
Premise Wiring, Central America
Premise Wiring, China
Premise Wiring, Europe
Wiring Systems, India
Int’l. Inc., Korea Branch
02/08
852-2836-7131
905-839-1138
506-309-4158
86-21-6374 2660
44-01283 500500
91-80-4022-4089
(82 2) 2607 1363
Fax:
Fax:
Fax:
Fax:
Fax:
Fax:
Fax:
852-2836-7132
905-839-9108
506-260-1616
86-21-6374 2799
44-01283 500400
91-80-4022-4033
(82 2) 2603 7386
Hubbell Premise Wiring, Latin America
Hubbell de Mexico, S.A. de C.V.
Hubbell Premise Wiring, Middle East
Hubbell Premise Wiring, Puerto Rico
Hubbell-Taian Co., Ltd., Taiwan
Hubbell Premise Wiring, Venezuela
305-408-4501
(5255) 9151-9999
971-4-393-4192
787-855-1075
886-2-2522-1862
58-212-5156482
Fax:
Fax:
Fax:
Fax:
Fax:
Fax:
Twist-Lock®, Kellems®, iFRAME®, NEXTSPEED®, OPTICHANNEL®, NEXTFRAME® are all registered trademarks of Hubbell Incorporated (Delaware).
305-408-8201
(5255) 9151-9989
971-4-393-4194
787-855-3265
886-2-2522-1872
58-212-6627258
Download