Data Center Solutions Guide Infrastructure Design in the The data center has become a critical asset of today’s information-intensive enterprise, supporting all the applications needed to maintain daily communication, productivity, and functionality. Designing and sustaining a data center capable of supporting these applications is a considerable undertaking, and a properly designed infrastructure is key to maximizing that investment both now and in the future. Design Issues Designing and implementing an infrastructure that maximizes data center management is vital to maintaining availability, operational efficiency, and aesthetics while also supporting growth, advances in technology, regulatory changes, and the increasing need for security. On the other hand, poor infrastructure design decisions can affect long-term reliability and total cost of ownership. Making some simple choices when designing the infrastructure can result in dramatic improvements for key data center issues such as: Air Flow, Response Time, Administration, Space Utilization, Security and Aesthetics. Increase in Power Consumption The increase in power density for active data center equipment has driven the cost of cooling and power consumption to a new level. Even with the improved efficiency and discipline of switching off idle equipment, and using more energy-efficient servers and switches, heat loads in a 42U cabinet have increased 12½ times over the past six years. And the best-case scenario has that number rising another 44% over the next six years. In fact, some experts estimate a requirement of 30 to 50 kilowatts for each cabinet or rack space!1 With higher-density cable bundles, an infrastructure design that helps manage airflow into and out of a cabinet is increasingly critical to equipment performance and lifespan, and ultimately data service levels. Cost of Downtime Downtime is costly and unacceptable in today’s data center. Recent studies show that estimated losses for downtime can run into the millions of dollars for many industries. With more than 50% of all data center infrastructure failures resulting from maintenance or other administration activities2, the data center infrastructure must enable IT managers to deploy equipment, complete reconfigurations, and respond to maintenance issues as quickly as possible. 2 Hubbell Premise Wiring • 14 Lord’s Hill Road • Stonington, CT 06378 • Tel: (860) 535-8326 • Fax: (860) 535-8328 Data Center Floor Space Cost The rising cost of environmentally controlled data center real estate, combined with the expense to cool the active equipment, means that space utilization must be carefully considered and efficiently managed. Not only is it important to maximize data center floor space utilization, but also the infrastructure must optimize rack space, minimize connections, and increase cabling density. Security The protection of data and equipment in today’s information-intensive enterprise has called for an increase in both logical and physical security. Not only do IT managers need to ensure that proper encryption and firewalls are in place, but the physical infrastructure must also protect and secure connections and equipment. Infrastructure products including sturdy, tamper-resistant enclosures and fault-resistant connections can go a long way in securing these critical assets. Aesthetics While data center availability is paramount, the data center must also showcase a company’s commitment to technology. When designing the infrastructure, innovative cabling management solutions can greatly improve the overall look and aesthetics of the data center, both at deployment and following future moves, adds, and changes. Aesthetics is also a benefit from a design that minimizes cable congestion. The Hubbell Committment As a global manufacturer of structured cabling systems, enclosures, and accessories, Hubbell Premise Wiring can help IT managers respond to the key data center issues of airflow, response time, administration, space utilization, security, and aesthetics. Hubbell is dedicated to delivering product innovation, advanced technology, the highest quality, and customer service excellence for the data center. To top it off, the Hubbell MISSION CRITICAL® program gives IT managers the assurance of system success with a 25-year guarantee on the components, performance, and installation integrity of your data center’s structured cabling infrastructure. 1. Brill, K. (2005) “2005-2010 Heat Density Trends in Data Processing, Computer Systems and Telecommunications Equipment” (Uptime Institute). 2. “Site Uptime® Procedures and Guidelines for Safely Performing Work in an Active Data Center”, CompuSite Engineering, Inc. and the Uptime Institute (2007). www.hubbell-premise.com Call 1-800-626-0005 3 Airflow The increasing array of active equipment designed into smaller packages results in more heat and more cable congestion, which impedes airflow. Impact Lower operating costs, longer equipment life expectancy. Design Objectives • Define air pathways. • Eliminate airflow obstructions. • Reduce cable bulk. • Condense connection form factor. Administration The ability to locate equipment, cables, and connections at all times is critical in the dynamic data center environment. Impact Lower operating costs. Design Objectives • Utilize a structured identification system. • Minimize infrastructure components. • Defined cable pathways and accessibility. Response Time As the enterprise strives to be more competitive, the organization must be able to dynamically and rapidly transform its communication and technology infrastructure for future growth. Impact Maximize uptime. Design Objectives • Minimize number of system component parts. • Factory-tested components. • Plug and play connections. • Maximum flexibility for moves, adds and changes (MACs). Total Cost of Ownership 4 Hubbell Premise Wiring • 14 Lord’s Hill Road • Stonington, CT 06378 • Tel: (860) 535-8326 • Fax: (860) 535-8328 Security Protection of mission critical data, adherence to regulatory requirements and defending against unauthorized access to equipment are key requirements for today’s data center environment. Impact • Increased revenue - protection of proprietary information. • Increased customer confidence. Design Objectives • Control access to data center. • Factory-sealed components. • Limit physical access to network connections. • Intrinsically secure media. • Use fault-tolerant connections. Space Utilization Maximizing utilization of expensive data center real estate is a key to controlling operating expenses. Impact Lower operating expense. Design Objectives • Minimize number of connections. • Maximize connection density. • Maximize floor space utilization. • Minimize cable pathway congestion. • Maximize rack and cabinet utilization. Aesthetics The Data Center is a reflection of the proficiency and the capability of the enterprise. Impact Positive customer perception - internal pride. Design Objectives • Covered cable management. • Stylized equipment racks and cabinets. • Minimize clutter and cable congestion. Hubbell can help you minimize the Total Cost of Ownership of your data center operation by providing you with solutions that exceed all of the design objectives. Minimize start-up costs, downtime and operating costs and maximize long-term reliability. All under the protection of the Hubbell 25-year MISSION CRITICAL® Cabling System Warranty. www.hubbell-premise.com Call 1-800-626-0005 5 MTP Plug and Play • 12 strand fiber has much smaller profile than equivalent UTP - removing a significant obstacle from air handling spaces. Laser optimized 50 micron fiber for 10GbE applications. • • Factory-sealed cassettes ensure secure connection. Optical fiber is immune to signal tapping. Reduces time to prepare for new servers by 50%. • Factory-terminated multimode and singlemode 12-fiber fanouts reduce onsite installation time. 100% optically tested for reliable performance. 12-Fiber MTP building cables with pulling grip attached. MTP keyed connector eliminates polarity questions. • • • Reduces cable bulk and improves airflow in plenum spaces, extending equipment life. Factory-terminated and tested cable assemblies increase reliability and minimize installation expense. 6 • High bandwidth fiber transmits more data per cable for optimum use of cable pathways. • Reduced cable congestion makes it easier to identify and trace ports and cables. • • Fewer cables eliminate unsightly clutter. Splicing connections concealed within cassette enclosure. OCLC62 MTP Cassette Hubbell Premise Wiring • 14 Lord’s Hill Road • Stonington, CT 06378 • Tel: (860) 535-8326 • Fax: (860) 535-8328 y System MTP Plug and Play System MTP Plug and Play Cassettes Connector Type SC Duplex SC Duplex SC Duplex SC Duplex ST-style ST-style ST-style LC Duplex LC Duplex LC Duplex LC Duplex LC Quad MT-RJ MT-RJ Fiber Type 50μm 50μm, 10GbE 62.5μm SM 50μm 62.5μm SM 50μm 50μm, 10GbE 62.5μm SM 50μm, 10GbE 50μm 62.5μm Catalog No. OCSC50 OCSC50G OCSC62 OCSCSM OCST50 OCST62 OCSTSM OCLC50 OCLC50G OCLC62 OCLCSM OCLCQ50G OCRJ50 OCRJ62 MTP to MTP 12-Fiber Cords with Pulling Grip Fiber Type Length 50μm 10m 50μm, 10GbE 10m 62.5μm 10m SM 10m 50μm 25m 50μm, 10GbE 25m 62.5μm 25m SM 25m 50μm 50m 50μm, 10GbE 50m 62.5μm 50m SM 50m 50μm 100m 50μm, 10GbE 100m 62.5μm 100m SM 100m Custom MTP cords available upon request. Catalog No. FPCMTP5010 FPCMTP50G10 FPCMTP6210 FPCMTPS10 FPCMTP5025 FPCMTP50G25 FPCMTP6225 FPCMTPS25 FPCMTP5050 FPCMTP50G50 FPCMTP6250 FPCMTPS50 FPCMTP50100 FPCMTP50G100 FPCMTP62100 FPCMTPS100 Please consult the Hubbell Premise Wiring Full Line Catalog for the complete fiber offering. FPCMTP50G10 12-fiber cord with pulling grip Photo at left shows the MTP Plug and Play components OCLC62 MTP Cassette and FPCMTP50G10 12-Fiber Cord with Pulling Grip. www.hubbell-premise.com Call 1-800-626-0005 7 Fiber Connections • • Laser optimized 50 micron fiber for 10GbE applications extends life of investment. • Optical fiber is immune to signal tapping. • 2CLICK™ no epoxy, no polish connectors allow prompt response if you require a connector change in the field. Fiber adapter panels snap in and out of all enclosures for easy customization and rapid change-outs. • Reduces cable bulk and improves airflow in plenum spaces, extending equipment life. Factory-terminated and tested cable assemblies increase reliability. Smaller cross section of fiber cords and cables saves valuable plenum and cabinet space Optical fiber cables and cords do not carry electrical energy and therefore, have no heat to dissipate. • High bandwidth fiber transmits more data per cable for optimum use of cable pathways. • Individual channels labeled on all patch cords from the factory. • Fewer cables eliminate unsightly clutter. 72-fiber LC Trunk Cable 8 Hubbell Premise Wiring • 14 Lord’s Hill Road • Stonington, CT 06378 • Tel: (860) 535-8326 • Fax: (860) 535-8328 Fiber Connections 2CLICK™ Pre-Polished LC Connectors Description Multimode, 50μm, 10G, 10-pk, Aqua Housing Multimode, 62.5μm, 10-pk, Beige Housing Singlemode, 10-pk, Blue Housing 2CLICK™ Pre-Polished SC Connectors Description Multimode, 50μm, 10G, 10-pk, Aqua Housing Multimode, 62.5μm, 10-pk, Beige Housing Singlemode, 10-pk, Blue Housing Catalog No. FCLC50GM10 FCLC62M10 FCLCSM10 Catalog No. FCSC50GM10 FCSC62M10 FCSCSM10 FSP Loaded Adapter Panels - LC Duplex - Phosphor Bronze Sleeves - MM Applications # Fibers # Adapters 12 6 12 6 Type LC Duplex Beige LC Duplex Aqua Version Standard High-Density Catalog No. FSPLCDM6 FSPLCDM6AQ FSP Loaded Adapter Panels - LC Quad - Phosphor Bronze Sleeves - MM Applications # Fibers # Adapters 12 3 12 3 24 6 24 6 Type LC Quad Beige LC Quad Aqua LC Quad Beige LC Quad Aqua Version Standard Standard High-Density High-Density Catalog No. FSPLCQM3 FSPLCQM3AQ FSPLCQM6 FSPLCQM6AQ FSP Loaded Adapter Panels - LC Duplex - Zirconia Sleeves - SM Applications # Fibers # Adapters 12 6 Type LC Duplex Blue Version Standard Catalog No. FSPLCDS6 FSP Loaded Adapter Panels - LC Quad - Zirconia Sleeves - SM Applications # Fibers # Adapters 12 3 24 6 Type LC Quad Blue LC Quad Blue Version Standard High-Density Catalog No. FSPLCQS3 FSPLCQS6 FSP Loaded Adapter Panels - SC Duplex - Phosphor Bronze Sleeves - MM Applications # Fibers # Adapters 12 6 12 6 Type SC Duplex Beige SC Duplex Aqua Version Standard Standard Catalog No. FSPSCBE6 FSPSCDM6AQ FSP Loaded Adapter Panels - SC Duplex - Zirconia Sleeves - SM Applications # Fibers # Adapters 12 6 Type SC Duplex Blue Version High-Density FTR Tray - FSP Adapter Panel Version Capacity 3 FSP adapter panels 6 FSP adapter panels 12 FSP adapter panels 15 FSP adapter panels Rack Units 1 2 3 4 Catalog No. FSPSCDS6 Catalog No. FTR175SP FTR350SP36 FTR525SP FTR700SP FCR Rack Mount Enclosures Accepts Height Rack Units Catalog No. 6 FSP series adapter panels 3.50” (89) 2 FCR350SP36R 9 FSP series adapter panels 3.50” (89) 2 FCR350SP54R 12 FSP series adapter panels 5.25” (133) 3 FCR525SPR 15 FSP series adapter panels 7.00” (178) 4 FCR700SP Other adapter colors are available. Pigtails, Patch Cords and Multifiber trunk cables are available in various cable styles. Please consult our Full Line Catalog for the complete fiber offering. Photo at left shows a Make-to-Order 72-fiber LC Trunk Cable and Single-Fiber Pigtails. www.hubbell-premise.com Call 1-800-626-0005 9 Ascent 10GbE System Supports a maximum bandwidth beyond 500MHz, extending life of investment. Cat 6A UTP delivers PoE more effectively than 5e, reducing utility expense by more than 50%. • Designed specifically for 10GbE applications providing a solid foundation for critical data intensive applications. • Termination time reduced by 75% through the use of quick lace design and the TX4PP 1-Punch tool. • Angled UDX panels eliminate horizontal cable management allowing for maximized rack space utilization. High density 36- and 48-port UDX panels maximize the total amount of jacks for each rack unit. • • • • • 10 PC6AGY03 Patch Cord All NEXTSPEED® Ascent 10GbE components have provisions for labeling for easy administration. Hubbell complements each product with standardized labels and software to simplify the task of identification. 10GbE bandwidth per cable minimizes cable count, improving appearance. Stylized panel aesthetics. HXJ6AGY Jacks Hubbell Premise Wiring • 14 Lord’s Hill Road • Stonington, CT 06378 • Tel: (860) 535-8326 • Fax: (860) 535-8328 m NEXTSPEED® Ascent 10GbE System NEXTSPEED® Ascent Patch Panels, 10GbE Description 24-port, 1 Rack U, Black 48-port, 2 Rack U, Black 96-port, 4 Rack U, Black 24-port, 1 Rack U, Silver 48-port, 2 Rack U, Silver 96-port, 4 Rack U, Silver P6A24US Wiring Universal Wiring Universal Wiring Universal Wiring Universal Wiring Universal Wiring Universal Wiring Catalog No. P6A24U P6A48U P6A96U P6A24US P6A48US P6A96US NEXTSPEED® Ascent Patch Cords, Cat 6A Description Wiring Catalog No. Patch Cord, Stranded Cat 6A T568B PC6AXXXX XX=Color: BK=Black, B=Blue, DG=Dark Gray, GN=Green, GY=Gray, OR=Orange, Y=Yellow. XX = Length: ‘03’ = 3’, ‘05’ = 5’, ‘07’ = 7’, 10’ = 10’, ‘15’ = 15’, ‘20’ = 20‘. NEXTSPEED® Ascent UTP Cable, 10GbE/Cat 6A Description Type Catalog No. UTP Cable, Category 6A, Solid Plenum C6ASPXX UTP Cable, Category 6A, Solid Riser C6ASRXX XX=Color: B=Blue, GN=Green, GY=Gray, OR=Orange, W=White, Y=Yellow. NEXTSPEED® Ascent 6-110 Block Kit, 10GbE/Cat 6A Description 64-Pair Kit with legs* 64-Pair Kit w/o legs* 192-Pair Kit with legs* * 6-110, 4-pair connecting clips. P6A48US Type Universal Universal Universal Keystone Jack Panels (Unloaded) Style High-Density Multimedia Angled Height 1U (1.75”) 2U (3.50”) 2U (3.50”) Ports 48 48 48 Catalog No. 6110FTK64WL 6110FTK64NL 6110FTK192WL Color Black Black Black Catalog No. UDX48E1U UDX48E UDXA48 XCELERATOR™ Modular Jacks, 10GbE Description Wiring Catalog No. XCELERATOR™ Jack, 10GbE 1 HXJ6AXX XX=Color: AL=Almond, BK=Black, B=Blue, EI=Electric Ivory, GY=Gray, GN=Green, LA=Light Almond, OW=Office White, OR=Orange, P=Purple, R=Red, TI=Telco Ivory W=White, Y=Yellow. Add ‘25’ to the end of the Catalog No. for 25-Pack option. 6110FTK64WL C6ASPB Cable www.hubbell-premise.com Please consult the Hubbell Premise Wiring Full Line Catalog for the complete UTP offering. Photo shown at left includes the components of Hubbell’s Ascent 10GbE System (P6A24US and P6A48US Patch Panels, HXJ6AGY Jacks, 6110FTK64WL Punch Down Blocks, PCGAGY03 Patch Cords and C6ASPB Cable). Call 1-800-626-0005 11 Shielded 10GbE Syst Elimination of AXT and EMI, minimizing trouble-shooting and downtime. • 10GbE FTP cable’s reduced OD optimizes airflow throughout the infrastructure. • Shielding protects against signal tapping and EMI. • The NEXTSPEED® shielded 10GbE enhanced performance FTP cabling system is designed specifically for 10GbE applications and provides a solid foundation for critical data intensive applications. Tool-less jack termination reduces FTP termination under 2 minutes. • Supports a maximum bandwidth beyond 500MHz, extending life of investment. • PSJ24 UDX panels maximize the total amount of shielded jacks for 1 rack unit. • All NEXTSPEED® shielded 10GbE components have provisions for labeling for easy administration. SJ62B Jacks • • 12 One-piece shielded jack construction. Smaller cable diameter reduces cable congestion. PS603GY Patch Cord Hubbell Premise Wiring • 14 Lord’s Hill Road • Stonington, CT 06378 • Tel: (860) 535-8326 • Fax: (860) 535-8328 tem NEXTSPEED® Shielded 10GbE System NEXTSPEED® Shielded Jacks, Category 6/10GbE Description Shielded Jack, Category 6/10GbE, 2-pack Shielded Jack, Category 6/10GbE, 24-pack B-Wired Catalog No. SJ62B SJ624B NEXTSPEED® Shielded Patch Panels, Unloaded Description Shielded Patch Panel, 24-port, 1U, Gray Wiring Universal A-Wired Catalog No. SJ62A SJ624A Catalog No. PSJ24 NEXTSPEED® Shielded Patch Cords, Category 6/10GbE Description Wiring Catalog No. Shielded Patch Cord, Stranded Patch Cable T568B PS6XXXX XX = Length: 03 = 3’, 05 = 5’, 07 = 7’, 10 = 10’, 15 = 15’, 20 = 20‘, 25 = 25’. XX = Color: B=Blue, GY=Gray. NEXTSPEED® FTP Cable, Category 6/10GbE C6FTPSB Cable Description Type FTP Cable, Category 6A, Solid Plenum FTP Cable, Category 6A, Solid Riser XX=Color, B=Blue, GY=Gray, PK=Pink, W=White. Catalog No. C6FTPSPXX C6FTPSRXX Please consult the Hubbell Premise Wiring Full Line Catalog for the complete shielded offering. PSJ24 Photo at left shows components of the Hubbell Shielded 10GbE System including PSJ24 Panel, SJ62B Jacks, PS603GY Patch Cords and C6FTPSB Cable. www.hubbell-premise.com Call 1-800-626-0005 13 25-Pair Gigabit Ass • • Substantially reduces time to prepare for new servers. Reduces cable bulk and improves airflow in plenum spaces. • 25-pair cable assemblies fasten to the rear of panel securing the connection onto the panel eliminating errant terminations. • • Third party verification to IEEE 802.3ab. Create a “plug and play” connection within the data center easily interfacing between switches (RJ21X) or standard patch panels (RJ45). Bandwidth beyond 100MHz. • Factory-terminated and tested cable assemblies increase reliability. 14 25 pair cable much smaller profile than equivalent 6-cable bundle of 4 pair UTP. Frees up valuable space in the cabinet and in the floor for maximum airflow. • • High-density configuration optimizes valuable rack space. Condensed cable size results in smaller cable channels, minimizing floor space footprint. • Much easier to track and manage a single 25-pair cable versus 6 4-pair UTP cables. • • Fewer cables eliminate unsightly clutter. Condense cable channel congestion. Hubbell Premise Wiring • 14 Lord’s Hill Road • Stonington, CT 06378 • Tel: (860) 535-8326 • Fax: (860) 535-8328 emblies 25-Pair Gigabit Assemblies 1000BASE-T Patch Panel Delivery: Finish: Ports 1 1000BASE-T patch panel, 4 mounting screws, 4 cable assembly screws. Durable, black powder coat. Height Width Depth Connectors Catalog No. 24 1.75” (45) 19” (483) 1.2” (31) Female 48 3.50” (89) 19” (483) 1.2” (31) Female PG24 PG48 25-Pair Cable Assemblies Delivery: 1 cable assembly supplied with mounting screws, male-to-male connectors and a choice of various connector configurations. Connector Angles Gender Catalog No. 180° to 90° Male-to-Male 525G21XXE* 180° to 180° 525G22XXE* Male-to-Male 110° to 110° Male-to-Male 525G33XXME* * XX denotes Length in feet: 05=5 feet, 10=10 feet, 15=15 feet. Please consult the Hubbell Premise Wiring Full Line Catalog for the complete high pair count offering. PG48 Patch Panel 525G2210E 25-pair Gigabit Cable Assembly www.hubbell-premise.com Photo at left shows components of the Hubbell 25-Pair Gigabit Cable Assemblies including the PG48 Patch Panel with the 525G2210E 25-Pair Cable Assembly. Call 1-800-626-0005 15 Vertical Patch Panel Eliminates 1000’ of cable in each cabinet when fully loaded. • Places data and KVM ports at each rack unit allowing use of short connecting cables and eliminating cable that would otherwise restrict airflow. • Accommodates primary, secondary and tertiary data ports at each rack position. • Options supporting 1GbE, 10GbE and optical fiber ensuring plenty of bandwidth. • By moving data connections along side of cabinet, 2 rack spaces are freed for the use of additional equipment. • Much easier to identify and trace ports and cables. • Double door provides open access to cable, conceals large cable channel. Concealed horizontal cable and short jumper connections result in nice neat installations. Stylized look enhances appearance of any computer room. Substantially reduces time to prepare for new servers. Modular construction provides migration path and scalability. • • 16 Hubbell Premise Wiring • 14 Lord’s Hill Road • Stonington, CT 06378 • Tel: (860) 535-8326 • Fax: (860) 535-8328 Vertical Patch Panels and Data Modules Hubbell Vertical Patch Panel Catalog No. VPH Vertical Patch Panel Delivery: 1 75” section, 2 Rolls of 10 VELCRO® brand ONE-WRAP® cable ties, 1 Kit installation hardware, 8 #12 attachment screws. Description No. of Data Module Locations 15 iFRAME® Vertical Patch Panel for Hubbell iFRAME® Server Cabinet Data Modules Hubbell 10GbE Jacks mounted in Vertical Patch Panel. Catalog No. VPH Data Module 1GbE Data Module (25-pair) # Ports/module 6 port module Panel Use Fits into Vertical Patch Panel Data Module opening to terminate 25 pair 1GbE cable assembly. Catalog No. VPP1G Blank Covers (10-pack) 0 Covers unused Data Module Openings VPMB iSTATION™ Module Bezel 8 Each bezel (VPMI) accepts 4 two-port modules (IM2K1GY), which snap into VPMI for data applications where individual jacks are desired (color coding, 10GbE). VPMI iSTATION™ Module, 2 2-port, gray Each module accepts 2 HXJ jacks or AV inserts and snaps into VPMI. IM2K1GY 10GbE (55m) Module, 6-port Fits into Vertical Patch Panel data module opening for use with Cat 6 UTP (10GbE - TSB-155) VPPC6 6 VELCRO® and ONE-WRAP® are registered trademarks of Velcro Industries B.V. Please consult the Hubbell Premise Wiring Full Line Catalog for the complete Vertical Patch Panel offering. Photo at left shows the VPH vertical patch panel connecting one-to-one to servers, minimizing patch cord cost and air blockage. www.hubbell-premise.com Call 1-800-626-0005 17 Server Cabinet • • • IN-FRAME design protects investment by allowing frame depth to be increased in the field. • • 3-Point door locking system. Optional locks for side covers. • Cable pathways are open facilitating movement and additions of servers. Rack positions are identified on all four uprights aiding the installation of new gear. Cable management spools snap into place. • Optimizes cooling, extending life of active equipment. IN-FRAME design optimizes airflow by creating designated cable pathways away from center of cabinet. Designed for HOT AISLE/COLD AISLE cooling. Mounting rails fasten directly to frame preventing airflow “slippage” around equipment. • • Optional split rails kit maximizes cabinet utilization by accommodating servers and switchgear in one cabinet. • Cable management spools with label fields to identify bundles of cable. Unobscured cable pathways simplify tracing cables. H1KT Top Kit Simplifies adding and moving servers. • • • 18 Stylized look enhances appearance of any computer room. IN-FRAME design facilitates consistent cabinet ganging. 2-H1E80E Hubbell Premise Wiring • 14 Lord’s Hill Road • Stonington, CT 06378 • Tel: (860) 535-8326 • Fax: (860) 535-8328 Server Cabinets and Accessories Server Cabinet Delivery: 1 Frame 2 Perforated doors, center opening 4 19" Mounting rails (square holes 2 Side panels, flush with M6 cage nuts) 1 Kit of 20 M6 cage nuts, screws and washers Finish: Durable powder coat, black. Description Height Width Depth Catalog No. Server Cabinet, 80"H 80" 24" 42" H1E80E Server Cabinet, 80"H, without sides 80" 24" 42" H1E80EX Server Cabinet, 80"H 80" 24" 36" H1E80ED Server Cabinet, 80"H, without sides 80" 24" 36" H1E80EDX Fan Tray Delivery: 1 fan tray assembly, wired, 1 kit mounting hardware. Description Catalog No. Fan kit, 114 CFM, 120 VAC, 60 Hz, 36 dBA HWKF120 HWKF230 H1KB Fan kit, 114 CFM, 230 VAC, 50 Hz, 36 dBA Blank plate with 4” fan/PVC conduit cut-out Telescopic Equipment Shelf Dimensions: 16.65”W x 29.2”D. Load capacity: 200 lbs. Delivery: 1 shelf pre-assembled with telescopic slides, 2 rear mounting brackets and 1 kit mounting hardware. Color Catalog. No. Black CKTSD Stationary Equipment Shelf Dimensions: 17.69”W x 29.29”D. Delivery: 1 shelf, washers, cage nuts, (4) #12-24 mounting screws, washers, cage nuts. Color Catalog. No. Black CKSSD Top Plate Includes 1 Mounting Plate, 4 snap in spools, 1 kit mounting hardware. Catalog No. H1KT Please consult the Hubbell Premise Wiring Full Line Catalog for the complete Server Cabinet offering. Photo shown at left shows two H1E80E Server Cabinets with H1KT Cable Management Top Kits. www.hubbell-premise.com Call 1-800-626-0005 19 Network Cabinet • IN-FRAME design optimizes airflow by creating designated cable pathways away from center of cabinet. Can be used in front to rear, side to side, and bottom to top airflow configurations. Optional top keeps cable clear of fan tray exhaust. • • 3-Point door locking system. Optional locks for side covers. • Cable pathways are open facilitating movement and additions of servers. Rack positions are identified on all four uprights aiding the installation of new gear. Cable management spools snap into place. Optional split rails kit maximizes cabinet utilization by accommodating servers and switchgear in one cabinet. • • IN-FRAME design protects investment by allowing frame depth to be increased in the field. • Optimizes cooling, extending life of active equipment. • • Superb cable management reduces administration time and operating expense. • Enhanced cable management features allow cable storage within the cabinet. • • Much easier to identify and trace ports and cables. Cable management spools with label fields to identify bundles of cable. Unobscured cable pathways simplify tracing cables. • • • Stylized look enhances appearance of any computer room. IN-FRAME design manages and conceals cable bundle. H1N84E 20 Hubbell Premise Wiring • 14 Lord’s Hill Road • Stonington, CT 06378 • Tel: (860) 535-8326 • Fax: (860) 535-8328 H1KX4 Networking Cabinet and Accessories Networking Cabinet Delivery: 1 Frame, 2 Perforated doors, left hinging, 4-19” Mounting rails (#12-24), 2 Side panels, 3” wide for cable management, 1 Kit of 20 dog-nosed screws, #12-24 x 5/8, 16 Cable management spools, snap in Finish: Durable powder coat, black. Networking Cabinet with Side Covers Rack Units 43 45 Overall Height 80.7” 84.2” Overall Width 30” 30” Networking Cabinet without Side Covers Rack Units 43 45 Movable snap in spools (Cat. # ICKSS) in top to route cable. Overall Height 80.7” 84.2” Overall Width 30” 30” Catalog No. 32” Depth Catalog No. 36” Depth H1N80E H1N84E H1N80ED H1N84ED Catalog No. 32” Depth Catalog No. 36” Depth H1N80X H1N84X H1N80XD H1N84XD Vertical Cable Management Options: • Snap in Spools (ICKSS). • Vertical Cable Management Rings (HC26VR2). • NEXTFRAME® Vertical Channels (i.e., VS76H, VS76, VS73) - for use without side covers. • Internal Vertical Organizer - for use with 3” side covers. (H1KV80, H1KV84). • Concealed by 3” Side Cover. Cable entry with integrated bend relief. Please consult Hubbell Premise Wiring Full Line Catalog for the complete Premise Cabinet offering. Photo at left shows an H1N84E Networking Cabinet and some of the cable management features of its IN-FRAME design. Unobstructed vertical cable pathways far forward and concealed. www.hubbell-premise.com Call 1-800-626-0005 21 Column System Increase usable rack space per square foot of floor space by more than 15%. Installs in half the time of a traditional rack. • Open design removes all barriers to forced and convective airflow. • Maximum coverage of exposed cables enhances security. • Cable pathways are open facilitating movement and additions of servers. Top ladder pieces cut to length and pre-drilled for 4” square work boxes at factory. Cable management spools snap into place. • • • Durable components designed to last the life of the cable plant. • • • • • • 22 Columns mount on 2’ pitch to align with floor and ceiling grids. 1,400 lb. load capacity and 100% utilization of rack space maximizes equipment density per square foot. Cable management spools with label fields to identify bundles of cable. Un-obscured cable pathways simplify tracing cables much easier to identify and trace ports and cables. 80% reduction in parts results in dramatic reduction in number of brackets resulting in clean uncluttered appearance*. Double hinging covers project image of quality. Stylized look enhances appearance of any computer room. * Compared to traditional relay rack with accessories. Hubbell Premise Wiring • 14 Lord’s Hill Road • Stonington, CT 06378 • Tel: (860) 535-8326 • Fax: (860) 535-8328 4-IS7 and 3-ICKL mounted on top iFRAME® Columns Delivery: 1 iFRAME® column weldment, 1 Bottom alignment installation aid and floor template, 1 iFRAME® top plate, 1 Full height front cover with dual-acting hinges*, 4 Heavy-duty floor anchor washers, 4 anchors, 4 shims, 20-#12-24 x 5/8” dog point machine screws or M6 hardware for IS7M6, 4 Gates, 4” (ref. Catalog No. VCG4) and washers, 12 Snap in place cable routing spools, 1 Kit assembly hardware. * Not included in IS7E. For use in Applications: Rack Units Height Catalog No. Without raised floor 45 7’ IS7 Without raised floor 19 3’ IS3 Raised floor up to 12” high 45 8’ IS7RF When using M6 cage nuts 45 7’ IS7M6 Raised floor up to 12” high using M6 cage nuts 45 8.5’ IS7RFM6 Raised floor up to 18” high 45 8’ IS7RF18 As the rear columns in 4-post applications 45 7’ IS7E NOTE: Two columns must be ordered for the first rack in a line. Only one column needs to be ordered for each additional rack. iFRAME® Top Ladder Delivery: 1 iFRAME® 12” wide x 2’ top ladder with integrated waterfalls; pre drilled for 4” workbox, 1 kit assembly hardware. Finish: Durable black powder coat. Catalog No. ICKL Cable Management Spools Top plate (included with each column) aligns tops of columns and mounting for ladder rack. Delivery: Package of 50 spools and screws, 3½”, black. Catalog No. ICKSS Power Strip Mounting Brackets Delivery: 1 pair of brackets and hardware for mounting one Hubbell 66” power strip. Catalog No. ICKPM Please consult the Hubbell Premise Wiring Full Line Catalog for the complete Cable Management offering. IS7 with cable management door open www.hubbell-premise.com IS7 with cable management door closed Photo at left shows four IS7 7-foot iFRAME Columns in use. Call 1-800-626-0005 23 Cable Management Durable components designed to last the life of the cable plant. Maximize cable transmission performance. • Open design removes all barriers to forced and convective airflow. • Maximum coverage of exposed cables enhances security. • Organizers designed with rounded components to reduce the risk of cold flow and cable kinks to optimize transmission performance. Cable pathways are easily and completely open facilitating movement and additions of servers. • • Modular components can be field configured to meet the unique needs of each application. • Cable management spools with label fields to identify bundles of cable. Much easier to identify and trace ports and cables. • • 24 Un-obscured cable pathways simplify tracing cables. Hubbell Premise Wiring • 14 Lord’s Hill Road • Stonington, CT 06378 • Tel: (860) 535-8326 • Fax: (860) 535-8328 t CS1976 NEXTFRAME® Cable Management NEXTFRAME® 19” Equipment Rack with Z Channels, 6”W Delivery: 1 Rack, 7’H (HPW84RR19) and 2 vertical organizers (VS76H/VS76) Finish: Durable black powder coat. Rack Height Rack Units Finish Cover Style Catalog No. 7’ (2134) 45 Black Hinged CS1976H 7’ (2134) 45 Black Clip on CS1976 NEXTFRAME® 19” Duct Style Horizontal Organizers Delivery: 1 organizer, 4 #12-24x5/8” dog-nosed screws and Nylon washers. Panel Height Rack Units Front Ring Depth Rear Ring Depth Catalog No. 1.75” 1U 3.5” HC119CE3H 3.50” 2U 3.5” HC219CE3N 3.50” 2U 3.5” 4.6” HC219CC3N 5.25” 3U 3.5” HC319CE3N Other NEXTFRAME® Components • • • • Ladder Rack Center Rack Velcro® Cable Ties Wall Mount Racks and Brackets VELCRO® is a registered trademark of Velcro Industries B.V. Please consult the Hubbell Premise Wiring Full Line Catalog for the complete Horizontal Cable Management offering. Photo at left shows the CS1976 19” Equipment Rack with 6” Wide Z-Channels and HC219CE3N DuctStyle Horizontal Organizers. www.hubbell-premise.com Call 1-800-626-0005 25 TWIST-LOCK® Power Devices an Maximize up-time by preventing unintentional disconnects. • Power drops from above remove obstacles from airflow in plenum space. • • Prevents unintentional disconnect. Powerful, offsetting cord grips clamp on individual conductors and outer cord jacket to prevent strain on terminals. Ribbed nylon housing is impact and chemical resistant. • • Flexible connections allow for easy reconfiguration. • • Highly engineered materials maximize connection reliability at all temperatures. • No need to install a rigid power supply infrastructure. • • NEMA locking configurations for easy disconnect when repositioning data center equipment. KELLEMS® strain relief grips prevent conductor pulling, delivering a secure electrical connection. Flexible cord connections allow equipment to be powered without a rigid infrastructure to work around. KELLEMS® grips support flexible cable, eliminating the need for rigid wire management systems. Amperage and voltage indications are clearly marked on the device for easy identification. Individually molded face for each blade configuration keeps debris out of plug interior. • Integral dust shield. • Tough, ribbed Nylon housing for secure gripping. 26 Hubbell Wiring Device-Kellems • 185 Plains Road • Milford, CT 06461-2420 • Fax: (800) 255-1031 d Kellems Grips ® TWIST-LOCK® Devices 2-Pole/3-Wire TWIST-LOCK® Devices 3-Pole/4-Wire Connector Bodies Connector Bodies Amps KELLEMS® Dustight Strain Relief Grip. Voltage NEMA Catalog No. 15 125V L5-15R 20 125V L5-20R 20 250V L6-20R 30 250V L6-30R HBL4729C HBL2313 HBL2323 HBL2623 Plugs Amps TWIST-LOCK® Plug and Connector Body. Voltage NEMA Catalog No. 125V 125V 250V 250V L5-15P L5-20P L6-20P L6-30P HBL4720C HBL2311 HBL2321 HBL2621 Voltage NEMA Catalog No. 125V 125V 250V 250V L5-15R L5-20R L6-20R L6-30R HBL4700 HBL2310 HBL2320 HBL2620 15 20 20 30 Receptacles Amps 15 20 20 30 Amps 20 30 Voltage NEMA Catalog No. 3Ø480V 3Ø480V L6-20R L6-30R HBL2433 HBL2733 Voltage NEMA Catalog No. 3Ø480V 3Ø480V L6-20P L6-30P HBL2431 HBL2731 Voltage NEMA Catalog No. 3Ø480V 3Ø480V L6-20R L6-30R HBL2430 HBL2730 Plugs Amps 20 30 Receptacles Amps 20 30 KELLEMS® Dustight Strain Relief Grips Non-Insulated - Wide Range Strain Relief Cable Diameter Thread Size Range Inches (cm) N.P.T. Inches Mesh Length @ Nom. Dia. Inches (cm) .54”-.73” (1.37-1.85) ¾” 6½” (16.51) .73”-.97” (1.85-2.46) 1” 7” (17.78) .97”-1.25” (2.46-3.17) 1¼” 9” (22.86) .73”-.97” PG29 7” (17.78) 073031203 073031204 073031205 073PG291204 Insulated - Wide Range Strain Relief Cable Diameter Thread Size Range Inches (cm) Inches Mesh Length @ Nom. Dia. Inches (cm) Catalog No. .54”-.73” (1.37-1.85) ¾” N.P.S. 6½” (16.51) .73”-.97” (1.85-2.46) 1” N.P.S. 7” (17.78) (1.85-2.46) .97”-1.25” (2.46-3.17) 1¼” N.P.S. 9” (22.86) 1.25”-1.5” (3.17-3.81) 1½” N.P.T. 11¾” (29.84) 1.50”-1.70” (3.81-4.32) 2” N.P.T. 13¼” (33.65) Catalog No. 073031209 073031210 073031211 073031212 073031213 Please consult the Wiring Device-Kellems Full Line Catalog for our complete offering of TWIST-LOCK® Power Devices and Pulling and Support Grips. Photo at left shows a server cabinet connected to power with Hubbell TWIST-LOCK® Connector Cord Drops suspended using KELLEMS® Grips. www.hubbell-wiring.com Call (800) 288-6000 27 IEC Pin and Sleeve High Power 3-Phase power optimizes use of site power distribution unit. • 3-phase power cuts down cable bulk in plenum spaces. • • • Shrouding - pins are recessed for user safety and protection against abuse. Solid Pins - dependable solid brass for longer life and reliable electrical contact. Locking ring on plug prevents unintentional disconnect when mounted with receptacle or connector. Patented opening on plug shroud accommodates lock shackle to comply with OSHA lockout/tagout requirements. • • Dependable construction for longer life, reliable contact and less downtime. • • • 3-phase power optimizes circuit breaker space on Power Distribution Unit breaker panel. Tapered housings and ergonomic design eliminate bulky connections. • Ratings and certifications are molded into housing and devices are color-coded by voltage rating for easy identification. • Pin and Sleeve high power devices eliminate clutter and present a clean, orderly appearance. Insulated, non-metallic housing prevents marring of surfaces. • 28 IEC Pin and Sleeve devices provide convenient portable power and fast plug and play connections. Fast, secure connections. HBL430C7W Connector Body Hubbell Wiring Device-Kellems • 185 Plains Road • Milford, CT 06461-2420 • Fax: (800) 255-1031 r Connections IEC Watertight Pin and Sleeve Devices Connector Bodies Amps Voltage Catalog No. 30 3P/4W 3Ø480V 30 3P/4W 3Ø250V 30 3P/4W 125/250 60 3P/4W 3Ø480V 60 3P/4W 3Ø250V 60 3P/4W 125V/250V HBL430C7W HBL430C9W HBL430C12W HBL460C7W HBL460C9W HBL460C12W Plugs Amps Poles/Wires Voltage Catalog No. 30 Poles/Wires 3P/4W 3Ø480V 30 3P/4W 3Ø250V 30 3P/4W 125/250 60 3P/4W 3Ø480V 60 3P/4W 3Ø250V 60 3P/4W 125V/250V HBL430P7W HBL430P9W HBL430P12W HBL460C7W HBL460C9W HBL460C12W Voltage Catalog No. 3Ø480V 3Ø250V 125/250 3Ø480V 3Ø250V 125V/250V HBL430R7W HBL430R9W HBL430R12W HBL460R7W HBL460R9W HBL460R12W Receptacles Amps 30 30 30 60 60 60 Poles/Wires 3P/4W 3P/4W 3P/4W 3P/4W 3P/4W 3P/4W Please consult the Wiring Device-KELLEMS® Full Line Catalog for the complete Wiring Device Pin and Sleeve offering. HBL430P7W Plug Photo at left shows Hubbell HBL430P7W Plug and HBL430C7W Connector Body. www.hubbell-wiring.com Call (800) 288-6000 29 Power Distribution • • 3-phase power optimizes use of site power distribution unit breaker panel. • TWIST-LOCK® plugs prevent accidental disconnection of power cords. • Densely located receptacles ensure that there is always power available for new equipment. • Locating receptacles at each rack position minimizes length of power cord and eliminates clutter. • Color coded receptacles are a quick and easy way to identify phases at a glance. Cable management spools with label fields to identify bundles of cable. Improved airflow extends life of active equipment. Simplifying load balancing reduces energy costs. • • 30 3-phase power delivery reduces cable bulk below the raised floor eliminating obstacles to airflow. Locating receptacles at each rack position minimizes length of power cord bulk and eliminates obstacles to airflow. Unobscured cable pathways simplify tracing cables. Hubbell Premise Wiring • 14 Lord’s Hill Road • Stonington, CT 06378 • Tel: (860) 535-8326 • Fax: (860) 535-8328 Power Distribution Horizontal Power Strips Delivery: 1 power strip and 1 kit mounting hardware. Finish: Durable black powder coat. Electrical Specification Outlets Front Outlets Rear 15A/120V 0 10 15A/120V 0 10 15A/120V 4 4 20A/120V 0 10 20/16A, 120/250V 10 0 15A/120V 0 6 20A/120V 0 10 Catalog Number HPWPWR MCCPSS19 MCCPSS19TS PR10120 PR10720* PR0615 PR1020 PR0360** 60A/250V 0 3 * PR10720 includes an IEC 320 (C-20) inlet for power input. Vertical mount brackets are also included. ** PR0360 features 10’ cable with IEC 60A 2P/3W plug. Vertical Power Strips Delivery: 1 power strip and 1 kit mounting hardware. Finish: Durable black powder coat. Electrical Specification Outlets Number of Circuits 15A/120V 10 1 20A/120V 10 1 15A/120V 20 1 20A/120V 20 1 20A/120V 20 1 30A/120V 20 1 20/16A /circuit 120V 20 2 20/16A-120/250V 20 1 30/24A-250V 24 1 Catalog Number PR104 PR10420 PR206 PR20620 PR20820DRTL PR20830 PR20820A* PR20820I** PR24 PR40Z120*** 120V 40 6 * PR20820A features (2) 20A circuits each fed by 10ft. cable with NEMA 5-20 plug. ** PR20820I includes an IEC 320 (C-20) inlet for power input. *** Full length mounting bracket included. Please consult the Hubbell Premise Wiring Full Line Catalog for the complete Power offering. Photo at left shows a PR40Z120 40-Outlet Power Strip with 3Ø input connecting one-to-one with servers using 1-foot power cords with HBL5266C plugs. www.hubbell-premise.com Call 1-800-626-0005 31 Empower Your Enterprise With an Intelligent Infrastructure Solution. High Performance Copper Systems High Performance Fiber Connectivity Power Infrastructure Solutions Data Center Infrastructure Zone Cabling Systems Telecommunications Room Infrastructure Converged Workstation Outlets Delivery Systems Harsh Environments Wiring Devices KELLEMS® Grips RoHS Hubbell Premise Wiring Hubbell Wiring Device-Kellems 14 Lord’s Hill Road • Stonington, CT 06378-0901 (860) 535-8326 • 800-626-0005 • Fax: (860) 535-8328 Internet site: http://www.hubbell-premise.com 185 Plains Road • Milford, CT 06461-2420 (203) 882-4800 • (800) 288-6000 • Fax: (800) 255-1031 Internet site: http://www.hubbell-wiring.com HUBBELL INCORPORATED (Delaware) HUBBELL INCORPORATED (Delaware) B-DC1 02/08 Worldwide Locations Hubbell Hubbell Hubbell Hubbell Hubbell Hubbell Hubbell Premise Wiring, Asia Pacific Canada Inc. Premise Wiring, Central America Premise Wiring, China Premise Wiring, Europe Wiring Systems, India Int’l. Inc., Korea Branch 02/08 852-2836-7131 905-839-1138 506-309-4158 86-21-6374 2660 44-01283 500500 91-80-4022-4089 (82 2) 2607 1363 Fax: Fax: Fax: Fax: Fax: Fax: Fax: 852-2836-7132 905-839-9108 506-260-1616 86-21-6374 2799 44-01283 500400 91-80-4022-4033 (82 2) 2603 7386 Hubbell Premise Wiring, Latin America Hubbell de Mexico, S.A. de C.V. Hubbell Premise Wiring, Middle East Hubbell Premise Wiring, Puerto Rico Hubbell-Taian Co., Ltd., Taiwan Hubbell Premise Wiring, Venezuela 305-408-4501 (5255) 9151-9999 971-4-393-4192 787-855-1075 886-2-2522-1862 58-212-5156482 Fax: Fax: Fax: Fax: Fax: Fax: Twist-Lock®, Kellems®, iFRAME®, NEXTSPEED®, OPTICHANNEL®, NEXTFRAME® are all registered trademarks of Hubbell Incorporated (Delaware). 305-408-8201 (5255) 9151-9989 971-4-393-4194 787-855-3265 886-2-2522-1872 58-212-6627258