êbrit Operation and Instruction Manual for Digital Panel Meters This instruction manual is applicable for the following models of êbrit: No user serviceable parts in the meters. Warranty void if seal broken. In case of any complaints, please contact our customer care cell. Phone: 011 23235274 Email: customercare@hplindia.com/metersupport@hplindia.com HPL Electric & Power Pvt. Ltd. 1/21, Atma Ram Mansion, Asaf Ali Road, New Delhi-110002 Phone : 23234411, 23234811, 23236811; Fax : 23232639 E-Mail : hpl@hplindia.com, Website : www.hplindia.com This document is not contractual, HPL Electric & Power Pvt. Ltd. reserves the right to modify features without prior notice in view of continued improvements. Class 1.0 Class 0.5 êbrit êbrit êbrit êbrit êbrit êbrit êbrit êbrit êbrit êbrit êbrit êbrit êbrit êbrit V11 V31 A11 A31 W 11 PM31 P11 P31 Class 0.2 V12 V32 A12 A32 W 12 PM32 êbrit F13 GCPK4EBRIT-R2 ! Model Single Phase Voltmeter Three Phase Voltmeter Single Phase Ammeter Three Phase Ammeter Single Phase Kilowatt Meter Three Phase Power Meter Single Phase PF Meter Three Phase PF Meter Single Phase Frequency Meter HPL Electric & Power Pvt. Ltd. êbrit êbrit TEST CERTIFICATE Digital Panel Meter for AC measurement Contents Accuracy: Model: 1. Preliminary Operations ...................................... 02 2. Installation.......................................................... 02 3. Wiring Instructions ............................................. 03 4. Operation Mode................................................. 04 5. Programming Mode ........................................... 08 6. Technical Specification ...................................... 11 V11 V31 A11 A31 P11 W11 PM31 V12 V32 A12 A32 P31 W12 PM32 F13 Class 1.0 Class 0.5 Class 0.2 Range: 0-7A 0-750V 0 Lag-UPF-0 Lead 40.00-99.99 Hz 0-3.000 kW 0-3.300 kW/kVA/kVAr Ordering Information Model Item Code for Class 1.0 Item Code for Class 0.5 Item Code for Class 0.2 S/W Version Single Phase Voltmeter NPAMEBRITV11 NPAMEBRITV12 1.07 & above Three Phase Voltmeter NPAMEBRITV31 NPAMEBRITV32 1.07 & above Single Phase Ammeter NPAMEBRITA11 NPAMEBRITA12 1.07 & above Three Phase Ammeter NPAMEBRITA31 NPAMEBRITA32 1.07 & above Single Phase Kilowatt Meter NPAMEBRITW11 NPAMEBRITW12 3.04 & above Three Phase Power Meter PAMEBRITPM31 PAMEBRITPM32 5.03 & above Single Phase PF Meter NPAMEBRITP11 2.03 & above Three Phase PF Meter NPAMEBRITP31 6.00 & above Single Phase Frequency Meter Operation and Instruction Manual NPAMEBRITF13 4.01 & above 1 Operation and Instruction Manual 14 êbrit êbrit I. Programming 1. Preliminary Operations Voltmeter/Ammeter/Kilowatt meter CT Primary and Secondary Programmable CT Primary : 5 to 9999A for CT secondary 5A : 1 to 9999A for CT secondary 1A CT Secondary : 5/1A (Selectable) PT Primary and Secondary Programmable PT Primary : 110V, 1.1kV, 6.6kV, 11kV, 33kV 66kV, 132kV, 220kV or 440kV PT Secondary : 110V (Fixed) For personal & product safety please read the contents of these operation instructions carefully before connecting. Check the following after receipt of package : a. Power Meter CT Primary and Secondary Programmable CT Primary : 5 to 6550A for CT secondary 5A : 1 to 6550A for CT secondary 1A CT Secondary : 5/1A (Selectable) The Packing is in good condition. b. The Product is not been damaged during transit. c. The Product reference number confirms to the order placed. d. Operating Instructions as given in the manual. 2. Installation 2.1 Dimensions and cut-out J. Default Factory Settings +0.8mm -0.0mm Voltmeter/Kilowatt meter CT Primary : CT Secondary : +0.8mm -0.0mm Ammeter/Kilowatt meter/Power meter CT Primary : 5A CT Secondary : 5A 110V 110V Notes: 1. For Voltmeter and kilowatt meter without an external PT please use the default PT Ratio of 110/110V. 2. Max. Value of power ratio for kW meter is 1000000. Power Ratio = CT Ratio x PT Ratio. Example: If user set CT as 9999 and then tries to set PT Ratio as 440kV then PT Ratio will not set and meter will display FAIL. 96mm 3. For Ammeter if the value exceeds 9999A then the LED indication for kilo will glow and meter will display . 4. For Voltmeter if value becomes 1000V then LED indication for kilo will glow and meter will display 1.000 on its display. Operation and Instruction Manual 2.2 The panel meter is to be firmly fixed using the 4 transparent fixing clips supplied with the meter. Use 0.5 to 2.5mm2 cable for voltage terminals. Use 3 to 6mm2 cable for current terminals. 13 Operation and Instruction Manual 2 êbrit 3. Wiring Instructions êbrit C. Resolution Voltage (Direct measurement) : 0.1V Current (Direct measurement) : 0.001 A P.F. : 0.01 (Single Phase PF Meter) 0.001 (Three Phase PF Meter) Frequency : 0.01Hz Kilowatt (Direct measurement) : 0.001kW Power (Direct measurement) : 0.001kW/kVA/kVAr 3.1 Read the instruction manual carefully before installation. 3.2 Connect the meter as per wiring diagram shown. 3.3 Ensure that cable connections are properly tightened. 3.4 Use external fuses for voltage and auxiliary supply circuit. 3.5 Wiring Diagram. For Ammeter D. Display 80-300V AC/DC Display Display Range 80-300V AC/DC FUSE 0.5A FUSE 0.5A AUXILIARY SUPPLY Decimal Indications AUXILIARY SUPPLY P N P N ! ! CURRENT INPUT I1 I3 I2 CURRENT INPUT S1 S2 S1 S2 S1 S2 S1 S2 : 14 mm Seven segment LED : 0 to 9999 0 to 999 (For PF meter) : Auto adjust : R, Y, B Colored LED indication for 3 phase meters : LED indication for kilo & mega (only for kW meter) : Lag/Lead indication for PF meter : Power indication (kW, kVA, kVAr) for Power Meter E. Mechanical P1 S1 P2 S2 P1 P2 S1 S2 P1 S1 P1 S1 Enclosure Material Bezel Size Panel Cutout Weight P2 S2 P2 S2 Three Phase Ammeter Single Phase Ammeter Voltmeter/Ammeter/Kilowatt meter/Power meter Class 1.0 : ±1% of measured value Class 0.5 : ±0.5% of measured value : ±0.01% PF meter Frequency meter Class 0.2 : ±0.2% of measured value 80-300V AC/DC FUSE 0.5A FUSE 0.5A AUXILIARY SUPPLY P N ! AUXILIARY SUPPLY P N VOLTAGE INPUT L1 L2 L3 N ! G. Environmental VOLTAGE INPUT Operational temperature : Storage temperature : Relative humidity : L N FUSE 0.5A FUSE 0.5A Three Phase Voltmeter o 0 to 60 C o -20 to 70 C 0 to 95% H. Safety IP Protection Device safety Operation and Instruction Manual Engineering Plastic 96 x 96 mm 92 x 92 mm < 320g Approx. F. Accuracy For Voltmeter and Frequency Meter 80-300V AC/DC : : : : Single Phase Voltmeter/Frequency Meter 3 Operation and Instruction Manual : : IP 54 on front plate As per IEC 61010 IEC 61326 (Power Meter) 12 êbrit êbrit For Single Phase PF Meter and Kilowatt Meter G. To change the password 1. After acceptance of password, Press “ digit will start blinking. D ” key for 3 sec. The left most P 80-300V AC/DC 2. Enter the new desired password from 0001 to 9999 as explained in section 4.2.E. N P 80-300V AC/DC N FUSE 0.5A FUSE 0.5A AUXILIARY SUPPLY AUXILIARY SUPPLY 3. Press “ ” key, display will show . The new password is programmed and the meter will automatically come out of the programming mode. ! For Three Phase PF Meter and Power Meter P P N ! I1 CURRENT INPUT VOLTAGE INPUT L S1 S2 Important: Please remember the password after changing it. Incase user forget the password the user must send the meter to the factory for factory settings, which cannot be done on site. S1S2 S1S2 S1S2 L1 N L1 P2 S1 S2 L1 L2 L3 N N FUSE 0.5A P1 VOLTAGE INPUT I3 I2 N ! CURRENT INPUT L2 L3 P1 S1 P2 S2 P1 S1 P2 S2 P1 S1 P2 S2 N 5. Technical Specification 4. Operation Mode A. Electrical Specification Auxiliary Power Supply Auxiliary burden Voltage circuit burden Current circuit burden : : : : 4.1. Normal Mode 80-300V AC/DC, 50Hz < 2.5VA at 230V < 0.5VA < 0.5VA A. 1. Switch ON the Auxiliary Power Supply. 2. 3. B. Measuring Range Voltage (Direct measurement) Current (Direct measurement) P.F. Frequency Kilowatt (Direct measurement) Power (Direct measurement) : : : : : : 0-750V AC 0-7A AC Zero Lead-Unity-Zero Lag 40.00-99.99Hz 0-3.000 kW 0-3.300 kW/kVA/kVAr (Phase Wise Power) 0-9.900 kW/kVA/kVAr (Total Power) Display will glow and display the message. (u3/a3/u1/a1/fr/pf/pf3/p1/pr53) & Ver.No.as per the model. After one second, meter starts displaying parameters in auto scroll mode. B. (1). Auto Scroll Mode a. Single Phase Meters: Single phase Voltmeter/Ammeter/Frequency meter/PF meter/Kilowatt meter will show the respective parameter on the screen. b. Three Phase Voltmeter Star Connection: The following parameters scroll one after another. 1. R Phase to Neutral Voltage 2. Y Phase to Neutral Voltage Note: In case of power meter Total active power is the absolute sum of all three phase active powers. Total apparent power is the absolute sum of all three phase apparent powers. Total reactive power is the algebraic sum of all three phase reactive powers. 3. B Phase to Neutral Voltage 4. R-Y Phase to Phase Voltage 5. Y-B Phase to Phase Voltage 6. R-B Phase to Phase Voltage Operation and Instruction Manual 11 Operation and Instruction Manual 4 êbrit êbrit c. Three Phase Voltmeters Delta Connection: The following parameters scroll one after another. 1. R-Y Phase to Phase Voltage 2. Y-B Phase to Phase Voltage 3. R-B Phase to Phase Voltage d. Three Phase Ammeter: The following parameters scroll one after another. 1. R Phase Current 2. Y Phase Current 3. B Phase Current D ” key, display will show the present secondary current. 4. To change the secondary current, press “ D ” key for 3 sec. and select desired value using “ D ” key (1A or 5A). 5. After selection press the “ ” key, display will show SAUE. The selected secondary current value is programmed. 6. Press “ 7. Press “ ” key, display will show D Note: (For power meter: 5 to 6550A for CT secondary 5A,1 to 6550A for CT secondary 1A). 8. Press “ ” key, display will show SA U E . The selected primary current value is programmed. Three Phase Power meter: The following parameters scroll one after another for active, apparent power & reactive power. 9. Press “ ” key, to exit the configuration mode. E. To enter the digits (i) Parameters display for active & apparent power: 1. R Phase Power 2. Y Phase Power 3. B Phase Power 4. Total Power 1. Press “ back. 2. Press “ D ” key to edit the left blinking digit, it will go from 0-9 and roll ” key to shift digit to right. 3. Follow Step 1 & 2 and enter the desired 4 digit value. (ii) Parameters display for reactive power: 1. R Phase Power Sign 2. R Phase Power 3. Y Phase Power Sign 4. Y Phase Power 5. B Phase Power Sign 6. B Phase Power 7. Total Power Sign 8. Total Power F. To change the power selection in Power meter (kW/kVAr/kVA) 1. After acceptance of the password, Press “ CT. ” key, display will show 2. Press “ ” display will show present power selection as P-PO or rPO or 5-PO. 3. To change the power selection, press and hold “ D ” key for 3 seconds and select desire power using “ D ” key (P-PO for kW or r-PO for kVAr or 5-PO for kVA). Note: If Voltage in any phase greater than 450V or secondary current greater than 7.5A the meter will display in corresponding phase. 4. After selection press “ power is selected. In case if any CT is connected in reverse, the corresponding Phase LED will Blink. Please correct the CT connection in such case. 5. Press “ Operation and Instruction Manual . ” key again, it will show the present primary current value. To change the primary current, press “ D ” key for 3 sec. and enter the desired value as explained in sec. 4.2.E (5 to 9999A for CT secondary 5A,1 to 9999A for CT secondary 1A). e. Three Phase PF meter: The following parameters scroll one after another. 1. R Phase PF 2. Y Phase PF 3. B Phase PF 4. System PF f. 3. Press “ 5 ” key, display will show . The new ” key to exit the programming mode. Operation and Instruction Manual 10 êbrit êbrit B. To change the PT ratio (Single Phase Voltmeter & Kilowatt Meter/Three Phase Voltmeter) 1. After acceptance of the password, press “ PT (for Voltmeter). 2. ” key, display will show 1. LCD Check - 8.8.8.8 2. In case of KW meter after pressing “ ” key display shows CT . Now again press “ ” key, display will show PT . 3. Press “ D ” key, display will show 2. PT . 3. Present Primary Voltage 4. Press “ D ” key. The display will show secondary voltage as 110V which is fixed. 5. Press the “ 6. Press “ D ” key, display will show 0110 (If Primary Voltage of 110V is selected) . 4. Present Secondary Voltage ” key, it will show the present primary voltage. 7. To change the value, Press “ D ” key for 3 sec. and select desired value using the “ D ” key (110V, 1.1kV, 6.6kV, 11kV, 33kV, 66kV, 132kV, 220kV or 440kV). 0110 (Secondary Voltage is 110V which is fixed) 5. Present Network Selection (This will be shown in three phase meter only) or as the case may be. 8. Then press the “ ” key, display will show SA U E . The selected Primary voltage value is programmed. 9. Press “ 6. Finally meter will return to set parameters in the auto scroll mode. ” key to exit the configuration mode. b. Ammeter (Single Phase and Three Phase): The following parameters will be displayed by pressing “ ” key once. C. To change the Network selection (Three Phase Voltmeter) 1. After acceptance of the password, press “ PT . 2. Press “ ” key, display will show ” key, display will show the present network or 3. To change the network, Press & Hold “ desired network using “ D ” key. 4. Then press the “ is selected. 3. Present Primary Current ” key for 3 sec. & select D ” key, display will show . The new network 0100 (If primary current of 100A is selected) 4. Present Secondary Current ” key to exit the configuration mode. D. To change the CT ratio (Single Phase Ammeter & Kilowatt Meter/Three Phase Ammeter & Power meter) 1. After acceptance of the password, press “ CT . 2. Press “ 1. LCD Check - 8.8.8.8 2. cT . 5. Press “ Push Button Mode a. Voltmeter (Single Phase & Three Phase): The following parameters will be displayed by pressing “ ” key once. D ” key, display will show Operation and Instruction Manual 0005 (If secondary current of 5A is selected) ” key, display will show 5. Finally meter will return to set parameters in the auto scroll mode. . 9 Operation and Instruction Manual 6 êbrit êbrit c. Kilowatt Meter (Single Phase): The following parameters will be displayed by pressing “ ” key once. 4. Present Secondary Current 1. LCD Check - 8.8.8.8 0005 (If Secondary Current of 5A is selected) 2. cT 5. Present power selection P-PO (active power) or r-PO (reactive power or 5-po (apparent power) as the case may be. 3. Present Primary Current 6. Finally meter will return to set parameters in the auto scroll mode. 0100 (If Primary Current of 100A is selected) e. Press the “ only). 4. Present Secondary Current f. 0005 (If Secondary Current of 5A is selected) D ” key to scroll through the parameters (for 3 phase meters Parameter Scroll Lock: (for 3 phase meters only) 5. pt 1. Press and HOLD “ D ” key till the display shows will show only the selected parameter. 6. Present Primary Voltage 2. To unlock press “ ” key. 3. In case of PF meter press “ ” key once and display will show .To unlock press “ ” key again and display will show 0110 (If Primary Voltage of 110V is selected) 7. Present Secondary Voltage . 4.2 Programming Mode A. To Enter in the programming mode 0110 (Secondary Voltage is 110V which is fixed) 1. Press and HOLD “ D ” & “ ” keys together for 3 sec. in order to enter the configuration mode. Now the meter will ask for password by displaying on the screen. 8. Finally meter will return to set parameters in the auto scroll mode. d. Power Meter (Three Phase): The following parameters will be displayed by pressing “ ” key once. 1. LCD Check - 8.8.8.8 2. The meter will then display 0001 with left most digit blinking. This is the default password. 3. If required, this default password can be retained. In order to proceed further in the programming mode press “ ” key 4 times. 2. cT 4. If the configuration password is not the default password then enter the password as mentioned in Sec 4.2.E 3. Present Primary Current 5. On successfully entering the password the meter will display F in e . 0100 (If primary current of 100A is selected) ! Operation and Instruction Manual D . The display 7 The default password to enter into the programming mode is 0001. Operation and Instruction Manual 8