TECHNICAL DATA SHEET 16” and 22” Glass Highbay File: SD0714 Rev. 2 06-08-17 CSA Approved For Damp Locations Rated for up to 55°C Ambient Temp. 'HT' High Temperature Option suitable for 65°C ambient. 8.80" SQ. [224mm] Available up to 750W Pulse Start and 1000W High Pressure Sodium & Metal Halide SPECIFICATIONS: • Low-Profile Housing, nut and hub are constructed of precision die-cast aluminum. Standard finish is Duraplex IITM White Electrostatic Powder coat. • CWA HID type ballast with high power factor. Capable starting temperature is -29°C for Metal Halide & -40°C for High Pressure Sodium & Pulse Start MH. • Prismatic glass reflector is made of durable borosilicate, with wire frame that supplies uplight for uniform lighting of ceiling and floor. Enclosed version dust cap provides positive mounting of reflector to ballast assembly. Thermal shock resistance provides security against reflector breakage. Glass will not corrode or pit in common industrial environments. Most chemical atmospheres, including those rich in acids, bases, salts, wet gases, solvents, oils and fuels have essentially no effect on useful life of unit. • Tempered clear glass lens hinged and latched to reflector, equipped with factory installed optical safety chain. • Standard mounting with hook and cord or threaded ¼ turn hob for ¾” NPT mount. Available with a Low Profile bracket where the ballast is mounted beside optical assembly for unusual applications. Wall Mount Arm available to allow mounting to virtually any vertical surface. • Porcelain, 4 kV pulse rated, Mogul based socket prevents lamp loosening. Open 250W MH comes with specific open fixture rated lamp socket. Coated lamp sources recommended for most Metal Halide and Pulse Start systems. Clear lamps are recommended for 1000W Metal Halide and all High Pressure Sodium. Restricted base Mogul socket (EX39) available for low wattage MH fixtures. • Compatible with Wide-Lite HiLo controls. • Comes with 3 year limited warranty. • 'HT' High Temperature option includes mandatory painted ballast housing (white standard, other finishes available), plus a combination of insulation sheets, ballast heat wedge & thermal compound spread on contacting surfaces, and larger ballast housing depending on wattage and source to meet the 65°C ambient. 400W = 24.5" MAX [622mm] 1000W = 27" MAX [686mm] OPEN 16" = 16.88" [429mm] 22" = 22.75" [578mm] 8.80" SQ. [224mm] ENCLOSED 400W = 25.31" MAX [643mm] 1000W = 27.63" MAX [702mm] 16" = 16.88" [429mm] 22" = 22.75" [578mm] ORDERING GUIDE: Example: GLO250MA16AM-TB Series Open/ Enclosed Lamp Wattage Light Source Reflector 3 Size GL : Glass Highbay O : Open E : Enclosed 150 : 150W 175 : 175W 250 : 250W 320 : 320W 350 : 350W 400 : 400W 750 : 750W 1000 :1000W MA : Metal Halide 1 PS : Pulse Start MH 2 LX : High Pressure Sodium 16 : 16” 22 : 22” 1 2 3 Options Voltage Colour AM : Quartz Socket & Relay EM : Auxiliary Quartz Socket Only HL : Hi-Lo Switching Controls L : Lamp Included QB : Quiet Ballast FS : Single Fuse (120,277,347V) 3C : 3’ of 16/3 ST Cabtire with 715 Open Hook 3CP : 3’ of 16/3 ST Cabtire and 715 Open Hook with 20 Amp Twist-Lock Plug HT : High Ambient Temp. (65°C) T : Tri Tap 1 : 120V 2 : 208V 3 : 240V 4 : 277V 5 : 408V 6 : 347V 7 : 600V Blank = White B : Black G : Grey Do not use open optics with Metal Halide lamps specified “For Use in Enclosed Fixtures Only” Pulse Start MH fixtures with open optics require open rated lamps for dedicated mogul socket, (DMS) 16” – MA(175,250,400W) LX(150,250,400W) PS(175,250,320,350,400W) 22” – MA(400,1000W) LX(400,1000W) PS(400,750W) PROJECT: _________________________________________________ TYPE: ___________________________ CATALOGUE NUMBER: _________________________________ KEENE is a Product Group of Canlyte, 455 Dobbie Drive, P.O. Box 874, Cambridge, ON. N1R 5W4 tel: 519-623-8820 fax: 519-623-4435 QF4010 rev. 3 02-09-18