EPC22-2 2' × 2' High Efficiency, e•poc® Full Distribution Luminaire / 2-Lamp T5, T5HO, T8, TT Project Information Project Name Type Catalog No. Date Construction Luminaire housing, end caps, and reflectors are die-formed code-gauge cold-rolled steel. Frameless optics system hinges from either side for easy access to lamps and electrical components. Mechanical light trap prevents light leaks. Latches are spring loaded. Features • T5, T8, and twin tube optical systems available • Full distribution provides controlled high angle light for visual comfort • Advanced optical design produces high efficiencies • Exclusive T8 EnergyMax® tuned 1.04 ballast factor ballast • Step dimming options available for both T5 and T8 expand energy savings opportunities • Low W/ft2 ratio meets the most restrictive lighting power density codes • Typically qualifies for EPAct tax deductions • Unique frameless optics system allows easy access to lamps and electrical from below the ceiling • Lens styles provide aesthetic alternatives • Low profile housing fits in tight plenum spaces • Patent pending Finish All visible parts are custom formulated soft, nonglare high-reflectance white powder coat finish, painted after fabrication. Shielding Lenses are high transmission extruded acrylic. Installation An access plate is furnished with each recessed fixture for fast wiring connections without the necessity to open the fixture or wireway. Electrical Standard class “P”, thermally protected, autoresetting HPF ballast, sound rated A. All ballast Ordering Information EPC 22 – 2 Model EPC e∙poc® Full Distribution Luminaire No. of Lamps 2 Two Size 22 2' × 2' Accessories (Order Separately) FK22 2' × 2' Single Flange Kit FKCR Flange Kit Row Adaptor Damp Label - standard Where available. 1 Page 1/2 Rev. 07/02/10 – G Grid SM Surface Mount For hard ceilings use flange kit. 2', T5: 14 Watt 2', T8: 17 Watt 2', T5HO: 24 Watt Twin Tube Compact, 2G11 Base: 40 Watt Emergency Field installation of battery packs requires use of remote test switch. Ceiling Compatibility Luminaire is available to fit exposed grid ceilings, or hard ceilings when a flange kit is ordered. Some options may increase fixture depth. For information on compatibility with specific ceilings, or where plenum depth is a problem, contact your Columbia Lighting representative. Four integral T-bar clips are standard. Certification All luminaires are built to UL 1598 standards and bear appropriate UL and cUL or CSA labels. Damp location labeling is standard. Emergency-equipped fixtures labeled UL 924. Example EPC22-224G-DL-EPU-F5835 Ceiling Type Lamp Type 14 17 24 40TT leads extend a minimum of 6" through access location. NEC/CEC-compliant ballast disconnect is standard. – Shielding DL Delta Profile – Air Function Blank Static A Air Handling SH Shield Profile – Options Voltage U 120V-277V 347 347V1 Ballast E Electronic T8, 0.88 Ballast Factor, Instant Start ED Electronic T8, T5 Dimming, Programmed Start1 ESD Electronic T8, 0.88 Ballast Factor, Step Dimming, Programmed Start ELW Electronic T8, 0.77 Ballast Factor, Low Wattage, Instant Start EHL Electronic T8, 1.18 Ballast Factor, High Wattage, Instant Start E104 Electronic T8, 1.04 Ballast Factor, Instant Start ESD104 Electronic T8, 1.04 Ballast Factor, Step Dimming, Programmed Start EP Electronic T5, T5HO, 1.0 Ballast Factor or T8, 0.88 Ballast Factor, Programmed Start EP95 Electronic T5, 0.95 Ballast Factor , Programmed Start (N/A T5HO, 1-Lamp) ESD95 Electronic T5, 0.95 Ballast Factor, Step Dimming, Programmed Start (N/A T5HO, 1-Lamp) EP115 Electronic T5, 1.15 Ballast Factor, Programmed Start (N/A T5HO, 1-Lamp) ESD115 Electronic T5, 1.15 Ballast Factor, Step Dimming, Programmed Start (N/A T5HO, 1-Lamp) ETT Electronic Twin Tube, Instant Start (specify voltage) EPTT Electronic Twin Tube, Programmed Start – C388 C488 C588 EL GLR GMF NYC NYCU 3-Wire Flex 4-Wire Flex 5-Wire Flex Emergency Battery Pack Fast Blow Fuse Slow Blow Fuse NYC Compliant NYC Compliant, Union Label Lamps FO730 FO735 FO741 FO830 FO835 FO841 F5830 F5835 F5841 FTT830 FTT835 FTT841 30K 75CRI T8 Lamps Installed 35K 75CRI T8 Lamps Installed 41K 75CRI T8 Lamps Installed 30K 82CRI T8 Lamps Installed 35K 82CRI T8 Lamps Installed 41K 82CRI T8 Lamps Installed 30K 85CRI T5 or T5HO Lamps Installed 35K 85CRI T5 or T5HO Lamps Installed 41K 85CRI T5 or T5HO Lamps Installed 30K Twin Tube Lamps Installed 35K Twin Tube Lamps Installed 41K Twin Tube Lamps Installed Recessed Architectural / EPC22-2 © 2010 Columbia Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Columbia Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Tech Support 864.678.1668 / Website www.columbialighting.com EPC22-2 2' × 2' High Efficiency, e•poc® Full Distribution Luminaire / 2-Lamp T5, T5HO, T8, TT Photometric Data Ballast Ballast Factor Lamp Lumens per Lamp Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in Feet Avg. Luminance (Candela/Sq. M.) Coefficients of Utilization (%) EPC22-224G-DL-EP e•poc™ Troffer Recessed 2' × 2' 2-lamp with two opal delta lenses ICN-2S24 1.00 F24T5HO 1750 52 Recessed 0° = 90 90° = 90 0° = 1.26 90° = 1.36 Length: 1.83 Width: 1.83 Height: 0.00 0.0 22.5 45.0 67.5 90.0 0 30 40 45 50 55 60 65 70 75 80 85 2726 2676 2627 2586 2540 2482 2398 2289 2124 1900 1629 1217 2726 2717 2694 2668 2635 2589 2539 2487 2425 2434 2277 1696 2726 2806 2824 2827 2835 2858 2918 3050 2960 2670 2166 1438 2726 2876 2945 2991 3055 3200 3323 3217 2894 2434 1944 1143 2726 2899 2987 3050 3155 3334 3368 3187 2801 2335 1832 1033 Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 0-180 19.3 32.1 59.0 76.9 76.9 RC RW 1 2 3 4 5 6 7 8 9 10 70 83 75 69 63 57 53 49 45 42 40 80 50 30 80 76 69 63 60 54 53 46 47 40 42 35 38 31 35 28 32 25 29 23 10 73 59 48 41 35 30 27 24 21 19 70 81 73 67 61 56 51 48 44 41 39 70 50 30 78 75 67 62 59 53 52 45 46 40 42 35 38 31 34 28 31 25 29 23 10 72 58 48 40 35 30 26 23 21 19 50 74 65 57 50 45 40 36 33 31 28 50 30 72 60 51 44 39 34 31 27 25 23 Indoor Candela Plot 10 70 57 47 40 34 30 26 23 21 19 0 0 64 53 44 37 32 28 24 22 19 17 90 75 450 60 900 0 15 RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance 30 45 Horiz 0-180 45.0 90.0 0.0 Energy Data Lumens % Lamp % Fixt. 677 1125 2065 2690 2690 RCR Luminaire Average Luminance Angle Luminaire Data Test 15106 Test Date 8/7/08 25.2 41.8 76.8 100.0 100.0 Total Luminaire Efficiency 76.9% Luminaire Efficacy Rating (LER) IESNA RP-1-1993 Compliance ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens 52 Non-Compliant Non-Compliant $4.62 based on 3000 hrs. and $0.08 per KWH Test 15109 Test Date 8/8/08 Ballast Ballast Factor Lamp Lumens per Lamp Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in Feet EPC22-217G-DL-E104U e•poc™ Troffer Recessed 2' × 2' 2-lamp with two opal delta lenses B232IUNV104-A 1.04 F17T8 1375 36 Recessed 0° = 90 90° = 90 0° = 1.25 90° = 1.36 Length: 1.83 Width: 1.83 Height: 0.00 0.0 22.5 45.0 67.5 90.0 0 30 40 45 50 55 60 65 70 75 80 85 2086 2038 1997 1968 1930 1883 1826 1742 1635 1478 1277 996 2086 2075 2048 2027 2005 1973 1929 1894 1842 1838 1703 1254 2086 2141 2152 2155 2160 2169 2211 2289 2199 1950 1573 1033 2086 2201 2253 2286 2335 2432 2513 2396 2133 1763 1407 811 2086 2219 2287 2336 2415 2544 2552 2373 2058 1701 1333 738 Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 0-180 Dimensional Data 18.8 31.2 57.3 74.3 74.3 RC RW 1 2 3 4 5 6 7 8 9 10 70 81 73 66 61 56 51 47 44 41 39 80 50 30 77 74 67 61 58 52 51 45 46 39 41 34 37 30 34 27 31 25 29 23 10 71 57 47 40 34 29 26 23 21 19 70 79 71 64 59 54 50 46 43 40 38 70 50 30 75 72 65 60 57 51 50 44 45 38 40 34 36 30 33 27 30 25 28 22 10 70 56 47 39 34 29 26 23 20 18 50 72 63 55 48 43 39 35 32 30 27 50 30 70 59 50 43 38 33 30 27 24 22 Indoor Candela Plot 10 67 55 46 39 33 29 25 23 20 18 0 0 62 51 42 36 31 27 24 21 19 17 RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance 90 75 350 60 700 0 15 0.0 30 45 Horiz 0-180 45.0 90.0 Energy Data Lumens % Lamp % Fixt. 517 859 1575 2043 2043 RCR Luminaire Avg. Luminance (Candela/Sq. M.) Coefficients of Utilization (%) Average Luminance Angle Luminaire Data 25.3 42.1 77.1 100.0 100.0 Total Luminaire Efficiency 74.3% Luminaire Efficacy Rating (LER) IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens 59 Non-Compliant $4.07 based on 3000 hrs. and $0.08 per KWH Ceiling Compatibility Type G 3³/₈" FKCR 24" Side End For lay-in installation in exposed grid ceilings. Maximum tee widths of 1" and maximum tee heights of 2" allowed. 24" For flanged fixtures in row configurations, the FKCR adapter bracket kit is required in addition to the FK22 kit. Order one less FKCR than the total number of fixtures in row. (Example: Row of two, order (2) FK22 & (1) FKCR) FK22 Flange Kit 24" NOTE: All dimensions are in inches; dimensions and specifications are subject to change without notice. Please consult factory or check sample for verification. Page 2/2 Rev. 07/02/10 Side End For hard ceiling applications, order FK22 flange kit. Flange kit wires directly into concealed ceiling opening for a clean, finished appearance. Row cut out dimensions using FK22s & FKCR adapters: Width 243/8", Length [24" × (# in row)] + 3/8". Example: (24" × 2) + 3/8" = 483/8" Flange kit cut out dimension for single unit only: 243/8" × 243/8" Recessed Architectural / EPC22-2 © 2010 Columbia Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Columbia Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Tech Support 864.678.1668 / Website www.columbialighting.com