www.co-ax.com data sheet E4.01-05/2010 coaxial valve type MK 10 DR 3/2 way valve pressure range orifice connection function direct acting PN 0-40 bar DN 10 mm thread valve normally closed (A ►B) symbol NC a B C b a b A valve normally open (A ►B) symbol NO a B C b a b A design pressure balanced, with spring return, intersecting switch-over body materials ① brass ② ③ brass, nickel plated ⑤ ④ ⑥ stainless steel valve seat synthetic resin on metal seal materials NBR FPM, CR, EPDM Above stated body materials refer to the valve port connections that get in contact with the media only! general specifications options ports MK special threads function pressure range bar details needed ■ orifice ■ port ■ function NC/NO ■ operating pressure ■ inlet pressure at A, B or C ■ flow rate ■ media ■ media temperature ■ ambient temperature ■ nominal voltage Kv value vacuum pressure-vacuum back pressure media abrasive media damping flow direction switching cycles switching time media temperature ambient temperature limit switches manual override approvals mounting weight additional equipment opening closing 1/min ms °C °C kg see pressure range 200 opening 40 closing 25 DC: -10 to +80 AC: -10 to +80 DC: -10 to +80 AC: -10 to +80 -30 to +120 -30 to +120 LR/GL/WAZ mounting brackets MK 2,2 upon request options Un Un DC AC 24 V DC 230 V 40-60 Hz AC direct-current magnet direct-current magnet with integrated rectifier special voltage upon request special voltage upon request insulation rating protection energized duty rating connection H IP65 ED 180°C optional additional equipment current consumption M12x1 actuation If order or application specifications are incomplete or imprecise there exists a risk of an incorrect technical design of the valve for the required application. As a consequence, the physical and / or chemical properties of the materials or seals used, may not be suitable for the intended application. m³/h leak rate P1 P2 P2 > P1 NC NO 0-16/0-25/0-40 A B max.40 / B A max.25 / A C max.40 / C A max.25 2,6 < 10-6 mbar•l•s-1 upon request see pressure range gaseous - liquid - contaminated electrical specifications nominal voltage The valves‘ technical design is based on media and application requirements. This can lead to deviations from the general specifications shown on the data sheet with regards to the design, sealing materials and characteristics. threads G 1/4 - G 3/4 N-coil H-coil 100% plug acc. DIN EN 175301-803 form A, 4 positions x 90° / wire diameter 6-8 mm connector acc. DESINA illuminated plug with varistor 24 V DC 1,00 A 230 V 40-60 Hz AC 0,13 A explosion proof terminal box M16x1,5 connector acc. VDMA 24 V DC 1,29 A 230 V 40-60 Hz AC 0,16 A limit switches ■ specifications not highlighted are standard specifications highlighted in grey are optional müller co-ax ag • Gottfried-Müller-Str. 1 • D-74670 Forchtenberg • Germany • fon +49(0)7947/828-0 • fax +49(0)7947/828-11 • Email info@co-ax.com type MK 10 DR �� �� � ���� � � � ����� �� �� function: NC closed when not energized (A ►B) � �� �� ����� �� constructive length type MK 10 DR L1 L2 L3 0-16/0-40 bar 113,5 23 30 0-64 bar 121,5 19 26 �� �� � ���� � � � ����� �� �� function: NO open when not energized (A ►B) � �� ����� �� �� The applic ation - specif ic layout relating to temperature, pressure c onditions, switching behavior, media and its c on sistency may restrict the range of use or nec essitate relevant modif ic ations to materials used and seal ar rangements. Rights reserved to make technical alterations • Not responsible for printing errors • Detailled drawings can be obtained upon request