www.elvac.eu RTU applications protection & communication Marian Kuruc Ostrava 2015 Energetics RTU protections RTU RTUs for control, protection, data acquisition and communication Content Overhead lines Reclosers Sectionalizers Cable lines Fault currents indicator Substations Telemetry Protection functions Functional interlocks Automatic standby operation (MV, LV) www.elvac.eu | www.rtu.cz Own products RTU RTUs for control, protection, data acquisition and communication Overhead lines - reclosers Circuit breaker equipped with a mechanism that can automatically close the breaker after it has been opened due to a fault. Protections used: Earth fault (Wisher, conductance, wattmetric, connection of the neutral resistor) Overcurrent Short circuit Recloser GVR Whipp & Bourne www.elvac.eu | www.rtu.cz Recloser Tavrida - Nižné Ružbachy (SK) - 300/220 Own products RTU RTUs for control, protection, data acquisition and communication Overhead lines - sectionalizers Sectionalizer is not rated to interrupt fault current Each sectionalizer detects and counts fault current interruptions by the recloser. After a pre-determined number of interruptions, the sectionalizer will open, thereby isolating the faulty section of the circuit, allowing the recloser to restore supply to the other non-fault sections. Protections used: Earth fault Overcurrent Short circuit Sectionalizer - Hať (CZ) www.elvac.eu | www.rtu.cz Own products RTU RTUs for control, protection, data acquisition and communication Example – earth fault simulation Configuration RTU7M with EP card - RTU7M EP-3UA/2.5/3-1U/100/120-4I/1A/30A-I EPG7 (7V AC / 45 mA AC) + HP amplifier (up to 20 A / 300 V AC) Testing of RTU in lab by replaying of real fault record captured by another RTU unit Protections used: Conductance, wattmetric www.elvac.eu | www.rtu.cz Own products RTU RTUs for control, protection, data acquisition and communication Cable lines – fault currents indicators Indicates the passage of fault current Reduce service interruptions by identifying the section of cable that has failed Protections used: Earth fault Overcurrent Short circuit www.elvac.eu | www.rtu.cz Own products RTU RTUs for control, protection, data acquisition and communication Substations – telemetry Controlling and data acquisition of: Digital inputs Digital outputs Analog inputs GPS time synchronization Communication protocols with SCADA: IEC 60870-5-101, IEC 60870-5-104 DNP3 HioCom2 Communication protocols with lower-level: IEC 60870-5-103, IEC 60870-5-104 DNP3 Modbus RTU/TCP HioCom2 Main and backup communication www.elvac.eu | www.rtu.cz Substation in Sofia (BG) – centralized solution Own products RTU RTUs for control, protection, data acquisition and communication Substations – protection relay MV, LV substations in factories and electricity distribution companies Connection to SCADA MKD Protections used: Earth fault Overcurrent - time (in)dependent Short circuit www.elvac.eu | www.rtu.cz Own products RTU RTUs for control, protection, data acquisition and communication Substations – functional interlocks Helps an equipment operator avoid mistakes ("mistake-proofing„), prevent incorrect operation by the user Mechanical, electrical and programmed interlocks Example: Bay interlocks Earthing switch closing: associated circuit breaker must be open Load break switch closing: earthing switch must be open Substation interlocks – across all bays Reactive power compensation capacitors must be connected to the same bus system (A or B) as a feeder Bus coupler breaker must be kept close during bus transfer operation Use of RTU expressions for interlocks www.elvac.eu | www.rtu.cz Own products RTU RTUs for control, protection, data acquisition and communication Substations – Automatic standby operation (MV, LV) The goal is to provide the automatic transfer of power for its associated load group from a normal power source to an alternate power source in the event the normal source fails Use of RTU expressions References: On Semiconductor, Rožnov pod Radhoštěm (CZ) - ongoing Západoslovenská distribučná (SK) Elektrárna Třebovice (CZ) www.elvac.eu | www.rtu.cz Own products RTU RTUs for control, protection, data acquisition and communication Substations – Automatic standby operation (MV, LV) The goal is to provide the automatic transfer of power for its associated load group from a normal power source to an alternate power source in the event the normal source fails Use of RTU expressions References: On Semiconductor, Rožnov pod Radhoštěm (CZ) - ongoing Západoslovenská distribučná (SK) Elektrárna Třebovice (CZ) www.elvac.eu | www.rtu.cz Own products Energetics RTU communication RTU RTUs for control, protection, data acquisition and communication Content Centralized solution Decentralized solution: Serial - RS-485, CIR ETH 100BaseFX www.elvac.eu | www.rtu.cz Own products RTU RTUs for control, protection, data acquisition and communication Communication – centralized solution One (or more) 19“ RTU units in one rack and connected using RS-485 or ethernet www.elvac.eu | www.rtu.cz Own products RTU RTUs for control, protection, data acquisition and communication Communication – centralized solution Pros: One (or more) 19“ RTU unit with indirect cards DI, DO, AI Easy integration of substation oriented interlocking functions. Hundreds of signals/measurements Cons: Cabling Only one signalling panel ESP7 Reference: ČEZ Bulgaria – substations in Sofia, Telegyr system replacement www.elvac.eu | www.rtu.cz Own products RTU RTUs for control, protection, data acquisition and communication Communication – decentralized solution RS-485 – small applications Concentrator – main SCADA Concentrator – backup RTU User Center - remote parametrization - fault records downloading RTU User Center - local parametrization - fault records downloading www.elvac.eu | www.rtu.cz Own products RTU RTUs for control, protection, data acquisition and communication Communication – decentralized solution CIR – optical redundant circle www.elvac.eu | www.rtu.cz Own products RTU RTUs for control, protection, data acquisition and communication Communication – decentralized solution Pros: Galvanically isolated redundant communication Easy integration of bay oriented interlocking functions Signalling panel ESP7 for each RTU unit Tens of RTUs on one communication circle Cons: 1 bay = 1 RTU Reference: ČEZ - Energetika Vítkovice – approx. 400 pcs RTU DEZA – substations RVN0.2, RVN0.3, RVN0.0, RVS – approx. 80 pcs RTU Energetika Třinec – approx. 80 pcs RTU Elektrárna Třebovice – 20 pcs RTU www.elvac.eu | www.rtu.cz Own products RTU RTUs for control, protection, data acquisition and communication Communication – decentralized solution 100BaseFX www.elvac.eu | www.rtu.cz Own products RTU RTUs for control, protection, data acquisition and communication Communication – decentralized solution Pros: Standardized and galvanically isolated industrial communication – possibility to connect 3rd party devices Easy integration of bay oriented interlocking functions Signalling panel ESP7 for each RTU unit Tens of RTUs on one communication circle Cons: 1 bay = 1x RTU + 1x 100BaseFX media converter Reference: Not installed yet www.elvac.eu | www.rtu.cz Own products RTU RTUs for control, protection, data acquisition and communication Communication – common features Remote parametrization over GPRS/3G network Fault records downloading Definování hlavní a záložní trasy na vzdálenou SCADA Possibility to add a local SCADA MKD Time synchronization – GPS Connection of existing devices – IEC103, IEC104, DNP3, Modbus atd. www.elvac.eu | www.rtu.cz Own products O Společnosti Thank you for your attention Hasičská 53, 700 30 Ostrava - Hrabůvka Czech Republic www.elvac.eu Tel.: +420 597 407 100 E-mail: sales@elvac.eu www.elvac.eu, www.rtu.cz RTU RTUs for control, protection, data acquisition and communication ELVAC RTU configuration web complete settings of RTU7C without SW RTU UC now we are preparing for the next RTU www.elvac.eu | www.rtu.cz Own products