Communication and User Interface • 100BaseT Ethernet Port • Expandable Serial Ports • Modbus and Modbus TCP • Over 24 Simultaneous Connections • Nexus™ RTU Functions • Programmable 256 Color XM L Based Display New Generation Power Quality • 10MHz Transient Recorder (166,000 Samples per Cycle) • 8 Channel Waveform Recorder • Voltage Surge, Sags and Transient Recording • Current Fault Signatures and Analysis • 1 Gigabyte Memory, Expandable Compact Flash A Quantum Leap in Metering Technology For customers from today’s utility giants, to Fortune 100 companies, to local electrical municipals, an effective energy management and power monitoring program is critical to success. The Nexus™ 1500 Meter, the most advanced OBTAIN HIGH -END POWER QUALITY & ACCURATE BILLING MEASUREMENTS High performance usage and power quality data is always available online in the Nexus™ power meter, providing the needed power system assessment immediately. The Nexus™ monitoring product to date, provides the total picture of 1500 Meter provides advanced power disturbance recording, power usage and power quality for any metered point within EN50160 Flicker Analysis and AI-based PQ reporting and a power distribution network, allowing users to make power analysis. Use the Nexus™ 1500 Meter's precision accuracy related decisions quickly and effectively. With EIG’s exclusive for primary metering, submetering or checking on an installed Total Web Solutions, you can monitor your Nexus™ 1500 Meter utility meter. anytime and from anywhere via the Internet. TECHNOLOGY DESIGNED FOR UTILITIES INDUSTRIAL USERS AND FOR ENERGY PROVIDERS (Utilities, Municipals, ESPs, Independents, etc.) Improve Substation Automation Solutions Increase Power Distribution Reliability Record Faults/Time Protective Equipment Monitor Reliability of Breakers and Relays Shed or Shift Loads Quickly Identify and Manage Peak Demand Heighten Response Time to PQ Events EXPANDABLE OPTIONS & TRENDING CUSTOMIZE THE NEXUS™ 1500 METER FOR EVERY APPLICATION The Nexus™ Meter offers virtually unlimited I/O capability Enhance Levels of Communication and Data Transmission in conjunction with all metering functions. Expandable Provide Real Time Data on the Web data-gathering applications. The meter's modular plug-in FOR ENERGY CONSUMERS (Industrial, Commercial, Government, etc.) options enable the meter to be used for all metering and design allows you to add Analog and Digital Output Modules to specifically meet your application. With this advanced capability, you can use the Nexus™ 1500 Meter to replace Real Time PQ Monitoring and Analysis Efficiently Control/Manage Energy Consumption Improve Operational Efficiencies Increase Productivity/Reduce Downtime Optimize Loads/Extend Equipment Life Identify and Respond to PQ Events Quickly Avoid High Utility Penalties for Exceeding Usage View Energy Usage and Power Quality through the Web Billing Data and System Reliability Monitoring RTUs and PLCs for energy management and substation automation solutions. 3 The Most Advanced Revenue Metering Technology Nexus™ 1500 Meter Accu-Measure™ Technology MULTIPART APPROACH TO PRECISION IN ACCURACY TIME OF USE CAPABILITY The Nexus™ 1500 Meter offers comprehensive time of use capability. The Nexus™ 1500 Meter is the first device of its kind to utilize EIG’s patent pending Standard features include: Accu-measure™ technology. Accu-measure™ • Bidirectional Consumption and Demand Quantities technology is a technique based on a multipart • 20 Year Calendar approach that allows a field-mounted metering device to achieve laboratory accuracy. 8 INDEPENDENT 16 BIT A/D CONVERTERS Eight 16 Bit A/D converters provide supreme sampling accuracy and resolution - no sample • 4 Seasons/Yr • 12 Holidays/Yr • 4 TOU Schedules/Seasons Real Time Readings & Waveform Display • Prior Month, Prior Season Storage skews causing accuracy errors. • Present Month, Present Season Storage DUAL INTERNAL REFERENCES • Hourly, Weekly Freeze Schedule The unit auto adjusts to dual internal references accurate to 1 part per million. These references ensure that the monitoring equipment maintains its calibration. AUTO-CALIBRATION COMPENSATION WITH TEMPERATURE The Nexus™ 1500 Meter uses an autocalibration technique that recalibrates the unit on the fly when the temperature changes more than 5 degrees Centigrade, thereby monitoring for accuracy over temperature. PRECISION ACCURACY SPECIFICATIONS With Accu-measure™ technology, this unit far exceeds all ANSI C-12 and IEC 687 MAX/MIN INTEGRATION AND RECORDING The unit offers time stamped max and min values for every measured reading. A time stamp is associated with each max and min. KW readings are integrated using: • Block (Fixed) Window • Thermal Window • Rolling (Sliding) Window • Predictive Window Any integration period is allowed. The default period is 15 minutes. COINCIDENTAL READINGS When logging max Watt readings, accuracy specifications. The unit offers the coincidental VARs at the time of 0.08% watt-hour accuracy. the max are also recorded. You can REVENUE METERING FEATURES TRANSFORMER LOSS, LINE LOSS, AND SUBSTATION LOSS COMPENSATION 4 Quadrant Energy and Demand determine the number of capacitors needed, peak inefficiencies and many other issues. The unit compensates for transformer and line losses. Power reading compensation is conducted for both iron and copper losses. PULSE AGGREGATION / UNIVERSAL METERING Using the status inputs, the Nexus™ 1500 Meter has the ability to count pulses and aggregate different loads providing a total picture of the load and its component parts. The pulse inputs can be used to accumulate and aggregate all other utility values such as water and gas. Historical Trends for Any Parameter Detailed Power Quality Recording 16 BIT WAVEFORM AND FAULT RECORDER The unit records up to 1024 samples per STATUS INPUT TRIGGERS The unit records the waveform at the INDEPENDENT CBEMA LOG PLOTTING The Nexus™ 1500 Meter stores cycle for an event with 10MHz voltage time of the status change. The input an independent CBEMA Log for transient sampling. Voltage and current change and waveform recording are magnitude and duration of voltage are recorded with pre- and post-event time stamped to a 1msec resolution. events. With this log, the user can analysis. Fault recording offers 8x full quickly view total surges, total sags scale capture capability. All voltage and ADDITIONAL INPUTS and average duration without having current readings are recorded using a The Nexus™ 1500 Meter offers to retrieve waveform information. 16 bit A/D converter providing precise inputs for Neutral to Ground Voltage waveform resolution. Both hardware measurements. This allows you to and software triggers are available to analyze rising ground potential which activate a waveform recording, which often damages electrical equipment. can be used for power quality surveys, The unit also calculates and measures fault analysis, breaker timing, etc. the neutral current. PHASOR ANALYSIS The monitor provides a phase angle analysis between the voltage and current channels, allowing for efficiency and system-integrity analysis. MEASURE AND RECORD HARMONICS TO THE 512TH ORDER SUBCYCLE TRANSIENT RECORDER The Nexus™ 1500 Meter is equipped The unit measures harmonics up to with 4 independent 10MHz analog to the 512th order for each voltage and digital converters that measure transient current channel. Real Time Harmonics samples 10 million times per second. are resolved to the 128th order. Percent The unit records subcycle transients on THD and K-Factor are also calculated. voltage and current readings. It monitors This high performance harmonic analysis switching noise from capacitors, static allows users to conduct power quality transfer switches, SCRs and many analysis at the high end of the harmonic other “power quality harmful” devices. spectrum. Transients are often the cause of intermittent and expensive periods of downtime. Without the Nexus™ 1500 Meter, solving these problems is often impossible. 5 Advanced Reporting and Analysis EN50160 FLICKER AND COMPLIANCE MONITORING INTERHARMONIC ANALYSIS It is important to maintain a source of high Using Communicator EXT, the Nexus™ quality power to insure efficient operations. 1500 meter provides users stored One particular source of disturbance that samples that can be used to view can have very negative effects is Flicker. Interharmonics, the discrete harmonics Flicker consists of low frequency (less that lie between the fundamental than 24Hz) to intermittent line disturbances frequency of voltage and current. on the power line. Aside from effects on Interharmonics which are not an integer equipment, disturbances of this type can multiple of the fundamental can now be have negative effects on people. observed and can appear as discrete frequencies or as a wide-band spectrum. Nexus™ 1500 Meter AiReports EXT - PQ Analysis AiReports EXT provides automated analysis and reports for abnormal events. • Uses Artificial Intelligence • Evaluates All Data from Nexus™ Meters • Rates Events for Severity • Identifies Probable Causes • Identifies Possible Impact • Recommends Corrective Actions or Solutions One particular example of this is the flickering of light sources that can affect The user can set a starting point humans in different ways, depending on the anywhere in the waveform, assuming severity. that there are enough sample points The Nexus™ 1500 Meter complies fully with the Flicker requirements of EN50160 and are not enough points in this waveform capture, the software will check the includes: - Flicker Evaluation-Instantaneous readings suitable for online monitoring; Short Term Readings available after the starting point. If there (PST - 10 Min) - Logging and monitoring - Long Term next waveform record(s) stored in the database. If it is contiguous, additional points up to 200ms will be retrieved for analysis. • Prepares & Formats Reports of All Power Quality Events • PQDIF File Format Converter allows the Nexus™ 1500 Meter's data to be read by standard EPRI Power Quality viewing software • COMTRADE File Converter changes fault records to standard fault analysis file formats Measure amplitudes and timing with millisecond resolution. See system reliability events that lasted for several seconds. Readings (PLT - 4 hour) - logging and monitoring - Polling - Pinst, Pst, Pst Max, Pst Min, Plt, Plt Max, Plt Min values - Log Viewer (View graphed values Pst and Plt for Va, Vb and Vc or displayed values including Max and Min.) Cutting-Edge Technology Monitors Your Power Quality Total Web Solutions Total Web Solutions— Providing Advanced Metering Data Integration with the Web WebMod Total Web Solutions is an advanced Ethernet (Open Architecture 3rd Party Integration) communication architecture allowing you to The 10/100BaseT design allows the unit display metering data and host your meter power to speak with 12 simultaneous sockets information web page directly on a Nexus™ meter. of Modbus TCP. The standard 100BaseT The Nexus™ meter directly hosts the web data Ethernet port allows multiple users to without any need for dedicated server software, access meter data without any interface. ActiveX Controls or Java Applets. The meter does the data collection, the formatting and the page hosting. Additionally, this solution is very Information Technology Department friendly because it creates almost no network traffic and provides all formatted data through an HTTP interface without resident • 12 Simultaneous Sockets Of Modbus Over Ethernet Communication • Multiple Sockets Means Multiple Users Or Software Systems Can Reach Meter Simultaneously client software. Advanced Features Include: • Direct Web Page Hosting With Live Readings • Read Direct From Meters (No Server Software Needed) • Low-Cost / High Functionality WebExplorer (Directly Host Metering Data) EIG’s WebExplorer provides you with direct access to all power data through Internet Explorer without needing to download ActiveX Controls or Java Applets. • Easily Incorporated Into Any Existing Web Applications Simultaneous Communications over TCP/IP TCP/IP Connection 7 1 Gigabyte Extensive Onboard Mass Memory Securely Records All Data Nexus™ 1500 Meter Multiple Programmable Memory Logs I/O HISTORICAL LOGS The Nexus™ 1500 Meter is equipped with vast amounts of memory. A user can partition this memory for log storage by setting up both the number of logs and the number of parameters per log. Up to 8 historical logs can be created with up to 128 parameters per log. OUT OF LIMIT LOG The unit offers an independent out of limit log. This allows a user to download out of limit information to obtain a sequence of events for any occurrence. Utilizing the 1msec clock resolution, the logs can be combined with different metered points throughout a distribution system to provide an accurate systemwide depiction of a power disturbance. The unit records the waveform when RELAY OUTPUT LOG a value goes out of limit and when the The unit records when a relay output from value returns to normal. All information the external Output Module is activated, is timestamped to the nearest 1msec. timestamps the event and provides a The 8 onboard high-speed inputs can reason for why the relay changed status. be tied to the waveform recording. You can record when a breaker tripped as compared to when the relay activated. This is very useful for fault and breaker integrity analysis. The unit can be programmed to take more than one recording every time an event occurs. Thousands of cycles can be recorded per event. CBEMA LOG The Nexus™ 1500 Meter stores a separate CBEMA log that records magnitude and duration of voltage and current surges and sags for every power quality event. This allows the user to conduct real time CBEMA analysis without downloading all stored waveforms. The separate CBEMA log EVENT-TRIGGERED WAVEFORM RECORDING LOG The Nexus™ 1500 Meter records waveforms with a resolution of up to 512 samples per cycle. The amount of waveform recording is based on the amount of memory installed. also allows the unit to provide a more comprehensive picture of power quality over time. INPUT STATUS LOG This log is similar to the Relay Output Log. It allows the user to record when the internal inputs change status. UPLOADABLE FLASH MEMORY The Nexus™ 1500 Meter utilizes uploadable flash memory technology on all processors and DSPs located in the unit. This insures that the unit can be upgraded without removing it from service. SET LIMIT CONTROL The Nexus™ 1500 power monitor provides programmable setpoints for user settings. This feature allows a user to configure the meter to be used as a control device for many applications such as: • Capacitor Control • Load Shedding • Automatic Transfer Schemes • Transformer Monitoring & Control • Redundant Protection (Not designed for Primary OverCurrent Protection) • Many Other Control Functions Onboard Communication for Every Application ROBUST COMMUNICATION CAPABILITIES AND I/O The Nexus™ 1500 Meter has many additional capabilities that allow it to communicate with almost any infrastructure. Basic communication is standard with the following: • Front Read ANSI Optical Port • Front Read USB Port • 10/100BaseT Ethernet with Total Web Solutions RJ-45 SYNC. CHECK-AUX. VOLT INPUT The unit has a high-speed Vaux input. This input can be used for multiple purposes • Neutral to Ground • Voltage Readings • Synchronizing Schemes The Vaux channel can be used to get the frequency, magnitude and phase angle on both sides of a switch or between generator and bus voltage. OPTIONAL ON-BOARD COMMUNICATION CAPABILITIES • 2 RS485 Ports STANDARD ON-BOARD I/O • 4 KYZ Pulses • 8 Status Inputs • IRIG-B GPS Clock Superior Construction and Isolation This unit is a rugged, durable CURRENT INPUTS COMMUNICATION PORTS OUTPUT MODULES device. It provides considerable All current inputs utilize EIG's All communication ports are Each output module is isolated protection and isolation from dual input technology. They isolated from the main unit and from the main unit and from damaging outside forces. can be terminated at the meter additionally isolated from each other output modules. No POWER SUPPLY or available as a CT wire pass other. This avoids dangerous signal entering an output The power supply offers both through. ground loops. module can damage any other part of the Meter. MOV protection and active line filtering to reduce any damage to the supply. VOLTAGE INPUTS The voltage inputs are galvanically isolated to 5000 Volts from I/O. Issues such as noisy 2 Expandable RS485 Ports 8 High-Speed Status Inputs IRIG-B Input Onboard Ethernet TCP/IP Connection ANSI Optical Port grounds, switching noise, SWC Revenue Lock or any other such problems pose no threat to the meter. Nema 12 Rated Color LCD 4 Voltage Inputs High Speed USB Port 2 Infrared Test Pulses Rugged 4 Current Inputs 9 Programmable Color LCD Display USER DEFINED PROGRAMMABLE DISPLAY Nexus™ 1500 Meter PROGRAMMABLE HMI The Nexus™ 1500 Meter uses unique XML based technology to allow users to define custom screens and screen functions. FULL METER LOG FUNCTIONALITY Real-time historical logs, waveform events and much more can be displayed by the meter. You can use the unit to view real-time trending, faults immediately after occurrence, and other time-critical information. Mounting and Installation Mounting Brackets Panel Mounted The Nexus™ 1500 meter is designed to mount in a panel. 1. Slide the meter into the panel. 2. From the back of the panel, slide 4 Mounting Brackets into the grooves on the top and bottom of the meter housing. 3. Snap the Mounting Brackets into place. 4. Secure the meter to the panel with lock washer and a #8 screw in each of the 4 mounting brackets. Nexus™ 1500 Meter Mounting Hole Dimensional Drawings Wiring Diagrams 11 Specifications Nexus™ 1500 Meter INPUT VOLTAGE RANGE • Voltage Transient: 10MHz SHIPPING • 720 Volts AC • 16 Bit A/D Resolution – Multiple Converters Total shipping weight: VOLTAGE INPUT WITHSTAND CAPABILITY • Utilizes patented Accu-measure™ approx. 5 lbs (2.3 kgs) • Voltage Inputs optically isolated to 2500V DC. Meets ANSI C37.90.1 (Surge Withstand Capability) INPUT CURRENT RANGE • 5 amp Inputs 4x continuous programmable to any CT range Technology Shipping container dimensions: 16" x13" x11" (40.64cm x 33.02cm x 27.94cm) • True RMS ACCURACY RATING COMPLIANCE • This unit complies with and exceeds • ANSI C12.20 Class 0.2 and IEC687 (Accuracy) ANSI C12.20 and IEC687 accuracy requirements. • ANSI C37.90.1 (Surge Withstand) • Fault Current recording to 80 amps peak secondary based on 5 amp full scale Note: 1 amp and 0.25 amp current inputs available as special order UPDATE TIME • ANSI C62.41 (Surge) • 1 Second — Revenue Accurate Readings • ANSI/IEEE C37.90.1 – Surge Withstand CURRENT INPUT WITHSTAND CAPABILITY • 200 msec — High Speed Readings • IEC 1000-4-2 – ESD • 100 amps for 10 Seconds CONTROL POWER REQUIREMENTS • IEC 1000-4-3 – Radiated Immunity • 300 amps for 1 Second • 90–264 Volts AC/DC (Suffix -D2) BURDEN • Burden: 40 VA Max • Voltage Inputs: 0.098VA Max FREQUENCY RANGE • Current Inputs: 0.008VA Max • 45Hz–75Hz ISOLATION COMMUNICATION FORMAT All inputs and outputs are isolated to 2500 Volts. All Com Ports are additionally isolated from each other. • Programmable parity and stop bits • IEC 1000-4-4 – Fast Transient • IEC 1000-4-5 – Surge Immunity • IEC 868 – Flicker Meter • IEC 61000-4-15 – Flicker Meter • CE Marked - Pending • UL and cUL Listed - Pending • Communication Protocols: Modbus TCP/IP, ASCII/RTU Covered by one or more of the following US patents: TEMPERATURE RATING • Operating Temperature: (0 to +60)°C • Optical Port 6,751,563 - Total Web Solutions • Humidity: Up to 95% Noncondensing • USB Virtual COM Port 7,155,350 - Virtual Switching SENSING METHOD • RJ-45 Ethernet Port – 100BaseT 6,735,535 - Auto-calibration • Up to 1024 Samples per Cycle (Programmable) • 2 RS485 Ports (optional) D 526920 - Design 6,636,030 - Transients Other Patents Pending Measurement Accuracy (% of Reading) PARAMETER High Speed 1 SECOND DISPLAY RESOLUTION Voltage (L-N) Voltage (L-L) Current Frequency KW @ Unity PF KW @ .5 PF KVA VAR PF Harmonics KW/Hours KVA/Hours KVAR/Hours 0.1% 0.01% 0.01% 0.025% 0.001 Hz 0.08% 0.1% 0.08% 0.08% 0.06% 0.1% 0.06% 0.08% 0.08% 5 Digit 5 Digit 5 Digit 00.001 Hz 5 Digit 5 Digit 5 Digit 5 Digit 3 Digit 3 Digit 9 Digit 9 Digit 9 Digit 0.1% 0.1% 0.01 Hz 0.1% 0.1% 0.1% 0.1% 0.1% N/A N/A N/A N/A Ordering Information Nexus™ 1500 Meter Ordering Specifications To order a Nexus™ 1500 Meter: 1. Fill out the options you want in the order chart shown on the right. List accessories separately. 2. Specify Communicator EXT 3.0. 3. If you provide CT and PT ratios and wiring, EIG will program the units at the factory. Control Power Nexus™ Base Meter Option Numbers: Example: Nexus™1500 Nexus™ 1500 Meter - Frequency Range D2 D2 90-264 Volts AC/DC Power Supply - Communication Expansion 60 Hz 60 Hz 50 Hz - 485P X No Option 485P 2 RS485 4 KYZ Pulses Accessory Options SOFTWARE COMEXT3.1C Communicator EXT 3.0 for Windows® Single-Computer License (One Site) COMEXT3.MC Communicator EXT 3.0 for Windows® Multiple-Computer License (One Site) AIEXT.1C AiReports EXT Power Analysis Software for Windows ® Single-Computer License (One Site) AIEXT.MC Multiple-Computer License (One Site) Electro Industries/GaugeTech The Leader in Web Accessed Power Monitoring 1800 Shames Drive • Westbury, NY 11590 1- 877-EIMETER (1- 877-346-3837) • Email: sales@electroind.com Tel: 516-334-0870 • Web Site: www.electroind.com • Fax: 516-338-4741 E154705 110507 A