3" Discharge Specifications

advertisement
HCP PUMPS
AMERICA
WWW.HCPPUMPSOFAMERICA.COM
Scope: Furnish and install___________
submersible Non-clog pump (s). Each pump shall
deliver the following performance
condition,___________ US GPM at ____________
TDH
With a shut off head of___________ft.
Volts______________ PH______________. The
pump (s) shall be manufactured or assembled in
North America for minimum of (5) years. HCP
Model________________.
Pump design: The pump (s) shall be capable of handling
Sewer, dewatering, process liquids and corrosive liquids with
passing a 1.5 inch solid. ( Permanent mount) The stainless
steel discharge base elbow shall be permanently mounted in
the wet well and connected to the discharge piping. The
pumps shall connect to the stainless steel guide rail base
automatically and guided by two stainless guide rails
extending from the top of the station to the discharge base
elbow. (Free standing) The pumps(s) is designed to install
without guide rails with a pedestal base made by the
manufacture so that the inlet of the pump is 6” off the wet well
floor All exposed hardware shall be stainless steel. The pump
(s) impeller, volute, seal plate housing and motor housing
shall be of a high quality SUS304 or SUS 316 stainless steel.
Pump (s) shall be capable of handling liquids with
temperatures to 120 degrees F and shall be capable of running
dry for extended periods.
The Pump and motor shaft shall be 420 stainless steel
supported by a lower Double roll ball bearing and an upper
single roll ball bearing.
Power cable: The pump shall be equipped with
__________ft of power cord. The ground wire shall be longer
than the motor
leads such that the ground connections are the last
1111-11
SF-P Series
SPECIFICATIONS
.2 HP to 3 HP Non-clog Pumps
3” NPT/Flanged Discharge
to be broken or pulled apart.
The pump cable shall be epoxy filled only around pumps
leads to prevent water from entering the pump housing
through the power cable. Epoxy is made into power cable
from the manufacture with cable grommet.
Shaft Seals: Each pump shall be equipped with (3) seals. The
lower seal shall be silicon carbide faces. The upper seal shall
be of Carbon/Ceramic. The third seal shall be located between
the lower seal and the impeller (Lip Seal) to prevent stringy
material form entering lower seal.
Auto Cut: Thermal sensor to monitor over current, located in
the terminal block. The auto cut will have an automatic reset.
Thermal sensors located in motor windings will not be
excepted.
Floats switch attached ( option): Floats must be a
incorporated form the manufacture and constructed into the
pump(s) cap housing. No “piggy back “ float will be excepted
in which the float is plugged in outside the pump housing.
Floats must be rated for 250 vac.
Motor Construction: The motor shall be Air filled water
tight chamber and be capable of continuous operation
underwater to a depth of 100 feet. The motor shall be a
submersible type rated for _________HP at
____________RPM. The full load amp shall not exceed
_________amps at _________volts. The motor shall have
class B insulation. The motor shall be designed for continuous
duty and non-overloading throughout the entire pump curve.
Impeller: The impeller shall be of a high quality SUS304 or
SUS316 stainless steel and shall be of a Semi-open design.
The impeller shall have a slip fit into the motor shaft and drive
key and secured to the shaft by a stainless steel bolt.
Start-up: The pump (s) shall be tested by a qualified
representative of the manufacture. Start-up reports provided
by the manufacture shall be completed and returned to the
manufacture before final approval.
HCP PUMPS
AMERICA
WWW.HCPPUMPSOFAMERICA.COM
Scope: Furnish and install___________
submersible Non-clog pump (s). Each pump shall
deliver the following performance
condition,___________ US GPM at ____________
TDH
With a shut off head of___________ft.
Volts______________ PH______________. The
pump (s) shall be manufactured or assembled in
North America for minimum of (5) years. HCP
Model________________.
Pump design: The pump (s) shall be capable of handling
Sewer, dewatering, process liquids and corrosive liquids with
passing a 1.5 inch solid. ( Permanent mount) The stainless
steel discharge base elbow shall be permanently mounted in
the wet well and connected to the discharge piping. The
pumps shall connect to the stainless steel guide rail base
automatically and guided by two stainless guide rails
extending from the top of the station to the discharge base
elbow. (Free standing) The pumps(s) is designed to install
without guide rails with a pedestal base made by the
manufacture so that the inlet of the pump is 6” off the wet well
floor All exposed hardware shall be stainless steel. The pump
(s) impeller, volute, seal plate housing and motor housing
shall be of a high quality SUS304 or SUS 316 stainless steel.
Pump (s) shall be capable of handling liquids with
temperatures to 120 degrees F and shall be capable of running
dry for extended periods.
The Pump and motor shaft shall be 420 stainless steel
supported by a lower Double roll ball bearing and an upper
single roll ball bearing.
Power cable: The pump shall be equipped with
__________ft of power cord. The ground wire shall be longer
than the motor
leads such that the ground connections are the last
1111-10
SF-U Series
SPECIFICATIONS
.5 HP to 5 HP Non-clog Pumps
2” & 3” NPT/Flanged Discharge
to be broken or pulled apart.
The pump cable shall be epoxy filled only around pumps
leads to prevent water from entering the pump housing
through the power cable. Epoxy is made into power cable
from the manufacture with cable grommet.
Shaft Seals: Each pump shall be equipped with (3) seals. The
lower seal shall be silicon carbide faces. The upper seal shall
be of Carbon/Ceramic. The third seal shall be located between
the lower seal and the impeller (Lip Seal) to prevent stringy
material form entering lower seal.
Auto Cut: Thermal sensor to monitor over current, located in
the terminal block. The auto cut will have an automatic reset.
Thermal sensors located in motor windings will not be
excepted.
Floats switch attached ( option): Floats must be a
incorporated form the manufacture and constructed into the
pump(s) cap housing. No “piggy back “ float will be excepted
in which the float is plugged in outside the pump housing.
Floats must be rated for 250 vac.
Motor Construction: The motor shall be Air filled water
tight chamber and be capable of continuous operation
underwater to a depth of 100 feet. The motor shall be a
submersible type rated for _________HP at
____________RPM. The full load amp shall not exceed
_________amps at _________volts. The motor shall have
class B insulation ( 5 Hp class F insulation). Single phase
motors (s) that are rated for 230 volt shall be able to run at
100% capacity at 212 volts without overheating the motor.
The motor shall be designed for continuous duty and nonoverloading throughout the entire pump curve.
Impeller: The impeller shall be of a high quality SUS304 or
SUS316 stainless steel and shall be of a Semi-open/vortex
design. The impeller shall have a slip fit into the motor shaft
and drive key and secured to the shaft by a stainless steel bolt.
Start-up: The pump (s) shall be tested by a qualified
representative of the manufacture. Start-up reports provided
by the manufacture shall be completed and returned to the
manufacture before final approval.
Download