GMH8/GDH8 DUAL$AVER™ GAS FURNACES P RODUCT S PECIFICATIONS The Goodman® GMH8/GDH8 80% AFUE Dual$aver™ Convertible, Multi-Speed Multi-Position Gas Furnaces feature a patented aluminized-steel tubular heat exchanger and durable Silicon Nitride Hot Surface Ignition system. This furnace is run-tested for heating or combination heating/cooling applications. With a heavy-gauge, reinforced, insulated steel cabinet and durable baked enamel finish, this unit can be installed in a variety of locations. Standard Features 80% AFUE MULTI-POSITION, CONVERTIBLE, MULTI-SPEED • Patented TuffTube™ dual-diameter tubular heat exchanger with lifetime limited warranty plus 10-year limited furnace replacement warranty* • Two-stage gas valve with revolutionary new convertible technology that allows installer to activate the twostage valve with the flip of a dipswitch • Silicon Nitride igniter with patented adaptive learning control for maximum igniter life • Furnace control board with self-diagnostics, color-coded low-voltage terminals and provisions for electronic air cleaner and 24-volt humidifiers • Control board stores the last five diagnostic codes in memory; simple push-button activation outputs the fault history to a flashing red LED • Low constant fan allows homeowner to activate the low heat speed to efficiently circulate air throughout the home • Self-adjusting feature automatically adjusts furnace to high or low stage based on outside temperature without an outdoor temperature sensor Cabinet Features HEATING INPUT: 45,000–140,000 BTU/H • Fully insulated, heavy-gauge steel cabinet with durable baked-enamel finish • Foil-faced insulation lines the heat exchanger • Designed for multi-position installation: upflow, horizontal left or right • Removable bottom for side or bottom return applications • Convenient left or right connection for gas and electric service • Coil and furnace fit flush for most installations Online registration is required within 60 days of installation. SS-GMH8 www.goodmanmfg.com 1/09 Supersedes 11/08 PRODUCT SPECIFICATIONS NOMENCLATURE G M H 8 70 4 B X A 1 2 3 4 5,6,7 8 9 10 11 Brand G Goodman® Brand or Distinctions™ Revisions A Initial Release B 1st Revision C 2nd Revision Airflow Direction C Downflow/Horizontal D Dedicated Downflow H High Airflow K Dedicated Upflow M Upflow/Horizontal NOx N Natural Gas X Low NOx Description V Two-Stage/Variable-speed H Two-Stage/Multi-speed S Single-Stage/Multi-speed E Two-Stage/X-13 Motor A B C D AFUE 95 95% 9 90%+ 8 80% Cabinet Width 14” 17½” 21” 24½” Maximum CFM @ 0.5” ESP 3 1,200 4 1,600 5 2,000 045: 45,000 070: 70,000 090: 90,000 MBTU/h 115: 115,000 140: 140,000 ACCESSORIES Model Description GMH8 All Models GDH8 All Models LPM-05 LP Conversion Kit (Springs & Orifice) √ √ HA02 High-Altitude Natural Gas Kit √ √ AFE18-60A Fossil Fuel Kit √ √ FTK03A Twinning Kit √ SBT 14/17/21* Downflow Sub-base √ √ * Supplied by McDaniel Metals THERMOSTATS Model 2 Description CHT18-60 Cooling/Heating, Mechanical CH70TG Cooling/Heating, Digital, Non-programmable CHSATG Cooling/Heating, Mechanical H20TWR Heating Only, Mechanical www.goodmanmfg.com SS-GMH8 PRODUCT SPECIFICATIONS 90,000 90,000 90,000 115,000 140,000 72,000 72,000 72,000 92,000 112,000 64,000 64,000 64,000 80,000 96,000 80 80 80 80 80 3 4 5 5 5 30 - 60 35 - 65 40 - 70 45,000 36,000 32,000 80 25 - 55 3 70,000 56,000 48,000 80 25 - 55 3 4 4” 4 10”x 6” 10”x 6” 10”x 8” 10”x10” ⅓ ⅓ ½ ½ 4 4 4 4 4” 4” 4” 4” 2 3 4 5 385 770 GDH8 1155CX GDH8 0703AX GDH8 0904BX GDH8 0453AX GMH8 1405DN* GMH8 1155CN* GMH8 0905CN* GMH8 0904BN* GMH8 0903BN GMH8 0704BN* GMH8 0703AN* GMH8 0453AN* SPECIFICATIONS Heating Capacity 45,000 70,000 36,000 56,000 LP Gas Output¹ 32,000 48,000 AFUE² 80 80 Available AC @ 0.5” ESP 3 3 Temperature Rise Range (°F) 25 - 55 Input¹ Natural Gas Output¹ 70,000 56,000 48,000 80 4 20 - 50 90,000 115,000 72,000 92,000 64,000 80,000 80 80 30 - 60 40 - 70 4 5 Circulator Blower Size (D x W) Horsepower @ 1750 RPM Speed Vent Diameter³ No. of Burners 10”x 6” ⅓ 4 4 4” 4” 2 3 ½ 4 4” 3 10”x 8” ⅓ 4 4” 4 10”x 10” 290 580 385 770 290 580 8.1 12.5 8.1 15 amps 153 ½ 4 4” 4 4 4” 5 ¾ 4 4” 6 Filter Size (in2) Permanent4 Disposable 480 960 290 580 290 580 385 770 480 960 8.5 8.5 12.9 15 amps 130 153 12.9 Electrical Data Min. Circuit Ampacity 5 Max. Overcurrent Device6 Ship Weight (lbs) 120 130 143 12.5 14.7 163 120 175 * Low NOx model available 1– Natural Gas BTU/h; for altitudes above 2,000’, reduce input rating 4% for each 1,000’ above sea level. Low-fire rate is 75% of high-fire rate 2– DOE AFUE based upon Isolated Combustion System (ICS) 3– Vent diameter may vary depending upon vent length. Refer to the latest editions of the National Fuel Gas Code NFPA 54/ANSI Z223.1 (in the USA) and the Canada National Standard of Canada, CAN/CSA B149.1 and CAN/CSA B142.2 (in Canada). 4– Permanent air filter size is based on 600 FPM velocity. Check with filter manufacturer for specific details. 5– Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. 6– Refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted. Notes: • All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply. • Gas Service Connection ½” FPT • Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes. SS-GMH8 www.goodmanmfg.com 3 PRODUCT SPECIFICATIONS GMH8 DIMENSIONS GMH8 23¾” Model A B Model A B GMH80453AN* 14” 12½” GMH80904BN* 17½” 16” GMH80703AN* 14” 12½” GMH80905CN* 21” 19½” GMH80704BN* 17½” 16” GMH81155CN* 21” 19½” GMH80903BN 17½” 16” GMH81405DN* 24½” 23” * Low NOx model available. MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS Sides Rear Front¹ 1” 0” 3” Vent² SW B 6” 1” Top 1” ¹ 24” clearance for serviceability recommended. ² Single Wall Vent (SW) to be used only as a connector. Refer to the latest editions of the National Fuel Gas Code NFPA 54/ ANSI Z223.1 (in the USA) and the Canada National Standard of Canada, CAN/CSA B149.1 and CAN/CSA B142.2 (in Canada). Note: GMH8 approved for line contact in the horizontal position. 4 www.goodmanmfg.com SS-GMH8 PRODUCT SPECIFICATIONS GDH8 DIMENSIONS Goodman High Voltage Alt. Gas Inlet 23¾” Model A B Non-Combustible Floor Base GDH80453AXAA 14” 12½” SBT14 GDH80703AXAA 14” 12½” SBT14 GDH80904BXAA 17½” 16” SBT17 GDH81155CXAA 21” 19½” SBT21 Notes: • Line voltage wiring can enter through the right or left side of furnace. Low-voltage wiring can enter through the right or left side of furnace. • Conversion kits for high-altitude natural gas operation are available. Contact your Goodman distributor or dealer for details. • Installer must supply the following gas line fittings, according to which entrance is used: ◊ Left: One 90º street elbow; one 2½” pipe nipple; one 90º elbow; straight pipe; one ground joint union ◊ Right: Straight pipe to reach gas valve MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS Sides Rear Front¹ 1” 0” 3” Vent² SW B 6” 1” Top 1” ¹ 24” clearance for serviceability recommended. ² Single Wall Vent (SW) to be used only as a connector. Refer to the latest editions of the National Fuel Gas Code NFPA 54/ ANSI Z223.1 (in the USA) and the Canada National Standard of Canada, CAN/CSA B149.1 and CAN/CSA B142.2 (in Canada). SS-GMH8 www.goodmanmfg.com 5 PRODUCT SPECIFICATIONS GMH8 BLOWER PERFORMANCE SPECIFICATIONS (CFM & Temperature Rise vs. External Static Pressure) External Static Pressure, (Inches Water Column) Tons AC at 0.5” 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 ESP CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM CFM CFM Model (Heating Speed as Shipped) Motor Speed GMH80453AN* (Medium) High Med Med-Lo Low 3 2.5 2 1.5 1,555 1,165 927 699 --28 36 47 1,511 1,123 907 694 --30 37 48 1,459 1,100 889 668 --30 37 50 1,392 1,090 863 645 --30 38 51 1,344 1,048 853 636 25 32 39 52 1,279 1,017 822 592 1,201 970 800 566 1,120 903 746 524 GMH80703AN* (Medium) High Med Med-Lo Low 3 2.5 2 1.5 1,437 1,127 895 694 36 46 ----- 1,310 1,100 917 681 39 47 ----- 1,295 1,095 878 663 40 47 ----- 1,310 1,075 867 640 39 48 ----- 1,273 1,050 853 625 41 49 ----- 1,202 1,018 830 591 1,129 967 786 562 1,039 904 743 522 GMH80704BN* (Medium) High Med Med-Lo Low 4 3.5 3 2.5 2,234 1,676 1,342 1,089 23 31 38 47 2,151 1,653 1,335 1,085 24 31 39 48 2,076 1,648 1,321 1,078 25 31 39 48 1,990 1,581 1,313 1,071 26 33 39 48 1,897 1,555 1,291 1,057 27 33 40 49 1,803 1,492 1,261 1,040 1,710 1,414 1,215 986 1,569 1,352 1,149 932 GMH80903BN (Medium) High Med Med-Lo Low 3 2.5 2 1.5 1,593 1,186 957 742 42 56 ----- 1,561 1,160 940 710 43 57 ----- 1,567 1,160 937 685 42 57 ----- 1,543 1,135 921 663 43 58 ----- 1,493 1,118 895 635 44 59 ----- 1,420 1,089 861 611 1,343 1,045 826 578 1,230 983 778 476 GMH80904BN* (Medium) High Med Med-Lo Low 4 3.5 3 2.5 2,182 1,645 1,320 1,063 --40 49 60 2,127 1,628 1,305 1,061 31 40 49 60 2,056 1,615 1,310 1,057 32 40 49 61 1,974 1,597 1,310 1,056 33 41 50 61 1,895 1,541 1,295 1,039 35 43 51 61 1,809 1,491 1,267 1,025 1,715 1,440 1,217 1,005 1,588 1,350 1,139 948 GMH80905CN* (Medium) High Med Med-Lo Low 5 4 3.5 3 2,334 1,754 1,367 1,098 --39 47 58 2,334 1,735 1,380 1,109 --39 47 59 2,284 1,728 1,371 1,109 --40 47 59 2,135 1,685 1,374 1,088 --40 48 60 2,051 1,628 1,335 1,066 35 42 50 62 1,910 1,551 1,293 1,050 1,748 1,469 1,246 998 1,605 1,346 1,165 916 GMH81155CN* (Medium) High Med Med-Lo Low 5 4 3.5 3 2,481 1,738 1,364 1,137 --49 62 --- 2,395 1,732 1,378 1,142 35 49 62 --- 2,288 1,709 1,372 1,140 37 50 62 --- 2,217 1,686 1,372 1,114 38 50 62 --- 2,076 1,639 1,350 1,090 41 52 63 --- 1,999 1,585 1,313 1,056 1,858 1,492 1,261 954 1,732 1,385 1,125 860 GMH81405DN* (Medium) High Med Med-Lo Low 5 4 3.5 3 2,554 1,846 1,520 1,301 41 57 69 --- 2,435 1,773 1,500 1,274 43 59 70 --- 2,375 1,762 1,483 1,260 44 60 ----- 2,240 1,712 1,470 1,231 47 61 ----- 2,152 1,672 1,435 1,207 49 63 ----- 2,002 1,583 1,373 1,177 1,883 1,526 1,308 1,093 1,744 1,442 1,245 931 * Low NOx model available. Notes: • CFM in chart is without filter(s). Filters do not ship with this furnace, but must be provided by the installer. • All furnaces ship as high-speed cooling and medium-speed heating. Installer must adjust blower cooling and heating speed as needed. • For most applications, about 400 CFM per ton when cooling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. • The chart is for information only. For satisfactory operation, external static pressure should not exceed value shown on the rating plate. The shaded area indicates ranges in excess of recommended maximum heating static pressure. • The dashed (----) areas indicate a temperature rise not recommended for this model. • The above chart is for furnaces installed at 0-2000 feet. At higher altitudes, a properly de-rated unit will have approximately the same temperature rise at a particular CFM, while ESP at the CFM will be lower. 6 www.goodmanmfg.com SS-GMH8 SS-GMH8 www.goodmanmfg.com 10 20 30 40 50 60 70 30 80 90 100 40 50 60 700 600 CFM 90 100 2000 2200 2400 CFM 1800 1600 1400 OUTPUT BTU/HR x 1000 80 1200 1100 1000 900 70 800 FORMULAS 110 120 130 140 BTU OUTPUT = CFM x 1.08 x RISE BTU OUTPUT RISE = ÷ CFM 1.08 BTU OUTPUT vs TEMPERATURE RISE CHART 150 PRODUCT SPECIFICATIONS GMH8 BLOWER PERFORMANCE DATA CHART 7 TEMPERATURE RISE PRODUCT SPECIFICATIONS GDH8 BLOWER PERFORMANCE SPECIFICATIONS (CFM & Temperature Rise vs. External Static Pressure) Model Tons (Heating Motor AC at Speed as Speed 0.5” Shipped) ESP External Static Pressure, (Inches Water Column) 0.2 0.3 0.4 0.5 0.6 0.1 CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM 0.7 0.8 CFM CFM GDH8 0453AX (Med) High Med Med-Lo Low 3.0 2.5 2.0 1.5 1,435 1,140 899 691 --29 37 48 1,421 1,114 889 674 --30 37 49 1,380 1,084 875 665 --31 38 50 1,322 1,063 871 651 25 31 38 51 1,262 1,039 857 637 26 32 39 52 1,200 1,144 1,064 1,002 943 897 821 780 745 618 562 525 GDH8 0703AX (Med) High Med Med-Lo Low 3.0 2.5 2.0 1.5 1,406 1,153 890 690 37 45 ----- 1,393 1,101 896 682 37 47 ----- 1,379 1,077 873 664 37 48 ----- 1,307 1,039 862 631 39 50 ----- 1,262 1,028 834 616 41 50 ----- 1,208 1,145 1,070 987 947 885 798 771 727 583 549 509 GDH8 0904BX (Med) High Med Med-Lo Low 4.0 3.5 3.0 2.5 2,007 1,612 1,325 1,043 --41 50 --- 1,993 1,606 1,299 1,040 --41 51 --- 1,975 1,570 1,280 1,032 --42 52 --- 1,940 1,533 1,244 1,002 --43 53 --- 1,844 1,501 1,222 981 36 44 54 --- 1,770 1,668 1,559 1,448 1,373 1,301 1,186 1,140 1,079 955 915 869 GDH8 1155CX (Med) High Med Med-Lo Low 5.0 4.0 3.5 3.0 2,381 1,801 969 1,100 --47 ----- 2,312 1,667 1,062 1,094 --51 ----- 2,312 1,667 1,140 1,060 --51 ----- 2,219 1,638 1,223 1,031 --52 69 --- 2,134 1,613 1,269 1,001 40 53 67 --- 2,024 1,930 1,839 1,513 1,441 1,369 1,292 1,322 1,358 953 937 874 Notes: • CFM in chart is without filter(s). Filters do not ship with this furnace, but must be provided by the installer. If the furnace requires two return filters, this chart assumes both filters are installed. • All furnaces ship as high-speed cooling and medium-speed heating. Installer must adjust blower cooling and heating speed as needed. • For most jobs, about 400 CFM per ton when cooling is desirable. • INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE. • The chart is for information only. For satisfactory operation, external static pressure should not exceed value shown on the rating plate. The shaded area indicates ranges in excess of recommended maximum heating static pressure. • The dashed (----) areas indicate a temperature rise not recommended for this model. • The above chart is for U.S. furnaces installed at 0-2000 feet. At higher altitudes, a properly derated unit will have approximately the same temperature rise at a particular CFM, while ESP at the CFM will be lower. 8 www.goodmanmfg.com SS-GMH8 SS-GMH8 www.goodmanmfg.com 10 20 30 40 50 60 70 30 80 90 100 40 50 60 700 600 CFM 90 100 2000 2200 2400 CFM 1800 1600 1400 OUTPUT BTU/HR x 1000 80 1200 1100 1000 900 70 800 FORMULAS 110 120 130 140 BTU OUTPUT = CFM x 1.08 x RISE BTU OUTPUT RISE = ÷ CFM 1.08 BTU OUTPUT vs TEMPERATURE RISE CHART 150 PRODUCT SPECIFICATIONS GDH8 BLOWER PERFORMANCE DATA CHART 9 TEMPERATURE RISE PRODUCT SPECIFICATIONS GMH8 WIRING DIAGRAM WARNING:DISCONNECT POWER BEFORE SERVICING.WIRING TO UNIT MUST BE PROPERLY POLARIZED AND GROUNDED. INTEGRATED CONTROL MODULE HUMIDIFIER XFMR (6) GND GND (8) 24 VAC HUM ID IFIER C2 MVC (9) HI GAS VALVE MVH (12) M1 MVL (2) C G R W 24V THERMOSTAT CONNECTIONS C Y 5 MIN 2 STG MODE BR 7 8 BL 9 4 5 6 1 2 3 AUXILARY LIMITS BR INTEGRATED CONTROL MODULE ID BLOWER PRESSURE SWITCH G PS ( 10) Y TO MICRO PSO (4) HLI (7) W HLO (1) R RO2 (11) RO1 (5) XFMR (3) 24 VAC RD RD 40 VA TRANSFORMER BR BL NO C RD PU XFMR-H FLAME SENSOR OR 2 XFMR-N 115 VAC YL YL 1 FP HOT SURFAC E IGNITER BK BK 24V XFMR IND-N CIRCULATOR BLWR BK 15 PIN PLUG ON SOME MODELS GR ID BLWR IND EAC-H ELECTRONIC AIR CLEANER LINE-N JUNCTION BOX BURNER COMPARTMENT BK WH DOOR SWITCH 24 VAC HUMIDIFIER DOOR SW ITCH SWITCH LOCATED IN BLOWER COMPARTMENT ON SOME MODELS NO EAC-N LINE-H BLOW ER COMPARTMENT C OR RD CIR-N CAP BR WH BR BR CICULATOR BLOWER BR BL 115V IGN-N INTEGRATED CONTROL MODULE PARK INTEGRATED CONTROL MODULE BK (HI) BL (MED) OR(MED LOW) RD (LOW) WH (N) PU WH IGN RD WH WH YL PRIMARY LIMIT PRESSURE SWITCH DISCONNECT YL RD YL YL WH BK L BR GND N TO 115VAC/ 1 Ø /60 HZ POWER SUPPLY WITH OVERCURRENT PROTECTION DEVICE BL BR BK PM 1 HOT SURFACE IGNITER C 2 HI 3 JUNCTION BOX WH 2 STAGE GAS VALV E LINE-N GND LINE H PU INDUCED DRAFT BLOWER PU PU FLAME SENSOR ROLLOU T LIMITS (SINGLE CONTROL ON SOME MODELS) 0 STEADY ON = NORMAL OPERATION OFF TO 115 VAC / 1/60HZ POWER SUPPLY WITH OVERCURRENT PROTECTION DEVICE LOW VOLTAGE (24V) = CONTROL FAILURE LOW VOLTAGE FIELD = SYSTEM LOCKOUT (RETRIES/RECYCLES EXCEEDED) 1 FLASH 2 FLASHES = PRESSURE SWITCH STUCK CLOSED HI VOLTAGE (115V) FLASHES = PRESSURE SWITCH STUCK OPEN FLASHES = OPEN HIGH LIMIT JUNCTION 5 FLASHES = FLAME SENSE WITHOUT GAS VALVE TERMINAL 6 FLASHES = OPEN ROLLOUT OR OPEN FUSE 7 FLASHES = LOW FLAME SIGNAL C RAPID FLASHES = REVERSED 115 VAC POLARITY/VERIFY GND PK PINK BR BROWN WH WHITE BL BLUE GY GRAY RD RED FIELD GND FIELD SPLICE HI VOLTAGE FIELD 3 4 COLOR CODES: YL YELLOW OR ORANGE PU PURPLE GR GREEN BK BLACK EQUIPMENT GND SWITCH (TEMP.) INTERNAL TO INTEGRATED CONTROL PLUG CONNECTION IGNITER SWITCH (PRESS.) OVERCURRENT PROT. DEVICE NOTES: 1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS. 2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING. 3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 105°C. USE COPPER CONDUCTORS ONLY. 4. BLOWER SPEEDS SHOULD BE ADJUSTED BY INSTALLER TO MATCH THE INSTALLATION REQUIREMENTS SO AS TO PROVIDE THE CORRECT HEATING TEMPERATURE RISE AND THE CORRECT COOLING CFM. (SEE SPEC SHEET FOR AIR FLOW CHART) 5. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES. 6. TO RECALL THE LAST 5 FAULTS, MOST RECENT TO LEAST RECENT, DEPRESS SWITCH FOR MORE THAN 2 SECONDS WHILE IN STANDBY(NO THERMOSTAT INPUTS). Wiring is subject to change. Always refer to the wiring diagram on the unit for most up-to-date wiring. WARNING 10 High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. www.goodmanmfg.com SS-GMH8 PRODUCT SPECIFICATIONS GDH8 WIRING DIAGRAM WARNING:DISCONNECT POWER BEFORE SERVICING.WIRING TO UNIT MUST BE PROPERLY POLARIZED AND GROUNDED. INTEGRATED CONTROL MODULE HUMIDIFIER XFMR (6) GND GND (8) 24 VAC HUM ID IFIER C2 MVC (9) HI GAS VALVE MVH (12) M1 MVL (2) C G R W 24V THERMOSTAT CONNECTIONS C Y 5 MIN 2 STG MODE BR 7 8 4 5 6 1 2 3 BL 9 AUXILARY LIMITS BR INTEGRATED CONTROL MODULE ID BLOWER PRESSURE SWITCH G PS ( 10) Y TO MICRO PSO (4) HLI (7) W HLO (1) R RO2 (11) RO1 (5) XFMR (3) 24 VAC RD RD 40 VA TRANSFORMER BR BL NO C RD PU XFMR-H FLAME SENSOR OR 2 XFMR-N 115 VAC YL YL 1 FP HOT SURFAC E IGNITER BK BK 24V XFMR IND-N CIRCULATOR BLWR BK 15 PIN PLUG ON SOME MODELS GR ID BLWR IND EAC-H ELECTRONIC AIR CLEANER LINE-N JUNCTION BOX BURNER COMPARTMENT BK WH DOOR SWITCH 24 VAC HUMIDIFIER DOOR SW ITCH SWITCH LOCATED IN BLOWER COMPARTMENT ON SOME MODELS NO EAC-N LINE-H BLOW ER COMPARTMENT C OR RD RD CIR-N CAP BR WH BR BR CICULATOR BLOWER BR BL 115V IGN-N INTEGRATED CONTROL MODULE PARK INTEGRATED CONTROL MODULE BK (HI) BL (MED) OR(MED LOW) RD (LOW) WH (N) PU WH IGN WH WH YL PRIMARY LIMIT PRESSURE SWITCH DISCONNECT YL RD YL YL WH BK L BR GND N TO 115VAC/ 1 Ø /60 HZ POWER SUPPLY WITH OVERCURRENT PROTECTION DEVICE BL BR BK PM 1 HOT SURFACE IGNITER C 2 HI 3 JUNCTION BOX WH 2 STAGE GAS VALV E LINE-N GND LINE H PU INDUCED DRAFT BLOWER PU PU FLAME SENSOR ROLLOU T LIMITS (SINGLE CONTROL ON SOME MODELS) STEADY ON = NORMAL OPERATION 0 OFF LOW VOLTAGE (24V) = CONTROL FAILURE LOW VOLTAGE FIELD = SYSTEM LOCKOUT (RETRIES/RECYCLES EXCEEDED) 1 FLASH 2 FLASHES = PRESSURE SWITCH STUCK CLOSED HI VOLTAGE (115V) FLASHES = OPEN HIGH LIMIT JUNCTION 5 FLASHES = FLAME SENSE WITHOUT GAS VALVE TERMINAL 6 FLASHES = OPEN ROLLOUT OR OPEN FUSE 7 FLASHES = LOW FLAME SIGNAL C RAPID FLASHES = REVERSED 115 VAC POLARITY/VERIFY GND PK PINK BR BROWN WH WHITE BL BLUE GY GRAY RD RED FIELD GND FIELD SPLICE SWITCH (TEMP.) 4 COLOR CODES: YL YELLOW OR ORANGE PU PURPLE GR GREEN BK BLACK EQUIPMENT GND HI VOLTAGE FIELD FLASHES = PRESSURE SWITCH STUCK OPEN 3 TO 115 VAC / 1/60HZ POWER SUPPLY WITH OVERCURRENT PROTECTION DEVICE INTERNAL TO INTEGRATED CONTROL PLUG CONNECTION IGNITER SWITCH (PRESS.) OVERCURRENT PROT. DEVICE NOTES: 1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS. 2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING. 3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 105°C. USE COPPER CONDUCTORS ONLY. 4. BLOWER SPEEDS SHOULD BE ADJUSTED BY INSTALLER TO MATCH THE INSTALLATION REQUIREMENTS SO AS TO PROVIDE THE CORRECT HEATING TEMPERATURE RISE AND THE CORRECT COOLING CFM. (SEE SPEC SHEET FOR AIR FLOW CHART) 5. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES. 6. TO RECALL THE LAST 5 FAULTS, MOST RECENT TO LEAST RECENT, DEPRESS SWITCH FOR MORE THAN 2 SECONDS WHILE IN STANDBY(NO THERMOSTAT INPUTS). Wiring is subject to change. Always refer to the wiring diagram on the unit for most up-to-date wiring. WARNING SS-GMH8 High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. www.goodmanmfg.com 11 PRODUCT SPECIFICATIONS DUAL$AVER CONFIGURATION & OPERATION Dual$aver This furnace is capable of the following heating modes: • Single Stage (Factory Setting) • Modified Two-Stage » Fixed 5-Min Low Stage » Auto Time (1-12 Min) Low Stage To change from the factory single-stage operation, adjust the dipswitches on the ignition control as follows: Off On Mode 5 Min Fixed Auto Mode Dipswitch 2nd Stage Delay Dipswitch Note: This furnace is designed to be used with a single-stage room thermostat. Start Start Call for Heat Call for Heat Safety Circuit Check Safety Circuit Check Start Furnace in Low Stage Low-Heat Blower Start Furnace in Low Stage Low-Heat Blower Delay Time (5 Min) Delay Time (1-12 Min) Gas Valve Switch to 2nd Stage Gas Valve Switch to 2nd Stage Blower Switch to Hi Heat Operation Blower Switch to Hi Heat Operation T-Stat Satisfied T-Stat Satisfied Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. © 2008 • Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in the USA. 12 www.goodmanmfg.com SS-GMH8