Level Plus ® ® Liquid-Level Sensors With Temposonics® Technology M-Series Model USTDII Digital Transmitter SENSORS Document Part Number 551412 Revision A Brief Operation Manual For Safe Use UNITED STATES GENERAL: OFFICE HOURS (EST): Tel: +1-919-677-0100 Fax: +1-919-677-2343 E-mail: sensorsinfo@mts.com http://www.mtssensors.com Monday - Thursday: 8:00 a.m. to 5:00 p.m. Friday: 8:00 a.m. to 4:00 p.m. REMITTANCE ADDRESS: MTS Systems Corporation Sensors Division NW 5872 P.O. Box 1450 Minneapolis, MN, 55486-5872 MAILING AND SHIPPING ADDRESS: MTS Systems Corporation Sensors Division 3001 Sheldon Drive Cary, North Carolina, 27513, USA TERMS & CONDITIONS: CUSTOMER SERVICE: The parties expressly agree that the purchase and use of Material and/ or Services from MTS Sensors Division are subject to MTS’ Terms and Conditions, in effect as of the date of this document, which are located at http://www.mtssensors.com/about/terms-and-conditions/index. html and are incorporated by reference into this and any ensuing contract. Printed Terms and Conditions can be provided upon request by e-mailing sensorsinfo@mts.com or if you prefer, go to http://www. mtssensors.com/index and click the Terms and Conditions link on the page footer to download the PDF. Tel: +1-800-457-6620 Fax: +1-800-498-4442 E-mail: orders@mts.com TECHNICAL SUPPORT AND APPLICATIONS: 24 Hour Emergency Technical Support Tel: +1-800-633-7609 e-mail: levelplus@mts.com GERMANY GENERAL: Tel.: +49-2351-9587-0 Fax:+49-2351-56491 e-mail: info@mtssensor.de http://www.mtssensor.de MAILING AND SHIPPING ADDRESS: MTS Sensor Technologie, GmbH & Co. KG Auf dem Schüffel 9 D - 58513 Lüdenscheid, Germany TECHNICAL SUPPORT AND APPLICATIONS: Tel.: +49-2351-9587-0 e-mail: info@mtssensor.de http://www.mtssensor.de JAPAN GENERAL: Tel.: +81-42-775-3838 Fax: +81-42-775-5516 e-mail: info@mtssensor.co.jp http://www.mtssensor.co.jp MAILING AND SHIPPING ADDRESS: MTS Sensors Technology Corporation 737 Aihara-cho, Machida-shi Tokyo 194-0211, Japan TECHNICAL SUPPORT AND APPLICATIONS: Tel.: +81-42-775-3838 Fax: +81-42-775-5512 MTS Sensors i Level Plus® Liquid-Level Sensors - M-Series Model USTDII Digital Transmitter Brief Operation Manual for Safe Use, Document Number: 551412 Revision A, 04/13 (US) Contact Information Model USTDII Brief Operation Manual for Safe Use Contact Information Model USTDII Brief Operation Manual for Safe Use Table of Contents Contact information United States .................................................................................. i Germany .........................................................................................i Japan ..............................................................................................i Safety Instructions Intended Use ....................................................................................1 Installation, commissioning and operation ......................................1 Special conditions for use in explosion-hazardous areas.................1 Model number identification Model number configuration ......................................................... 2 Marking .......................................................................................... 3 Entity parameters ........................................................................... 3 Table of Contents Basic wiring IS Installation ...................................................................................4 Wiring connections ......................................................................... 5 Safety barrier examples ................................................................. 6 Accessories Floats ............................................................................................. 7 Agency Information EC declaration of conformity .......................................................... 8 Level Plus® Liquid-Level Sensors - M-Series Model USTDII Digital Transmitter Brief Operation Manual for Safe Use, Document Number: 551412 Revision A, 04/13 (US) ii MTS Sensors Model USTDII Brief Operation Manual for Safe Use Safety Instructions Safety instructions The Brief Operation Manual for Safe Use contains safety instructions. For further information do consult the Operation and Installation Manual, document no.: 550980, available on the Level Product CD, part no.: 550766 supplied with your level transmitter or cost free download at www. mtssensors.com . The Level Plus® Model USTDII liquid level transmitter is used for continuous measurement of product level, interface level, and/or temperature of liquids in containers in hazardous areas. INSTALLATION, COMMISSIONING AND OPERATION • The liquid level transmitter may only be installed, connected, operated and maintained by trained technical personnel. The technical personnel must strictly adhere to the Operating Instructions, prevailing standards, legal regulations and certificates (depending on application). • If the Brief Operating Manual for Safe Use does not provide sufficient information, you must read the Operation and Installation Manual. There, you can find detailed information on the device. • The operator may only perform direct replacement of like components manufactured by MTS that are explicitly permitted in the Operating Instructions. • Do not operate damaged products and secure them against unintentional commissioning. Mark the damaged product as being defective. • If faults cannot be rectified, the products must be taken out of service and secured against unintentional commissioning. • The product is designed to meet state-of-the-art safety requirements, has been tested and left the factory in a condition in which it is safe to operate. Relevant regulations and European standards have been observed. • As the user, you are responsible for complying with the following safety conditions: - Installation instructions - Local prevailing standards and regulations • Only use the product according to its specification. SPECIAL CONDITIONS FOR USE IN EXPLOSION-HAZARDOUS AREAS • Model USTDII sensors may only be connected to certified intrinsically safe circuits (Ex ia or Ex ib). • The electronics housing is to be installed in zone 1 (category 2G, EPL Gb}. The sensor pipe/hose may be installed in zone 0 (category 1, EPL Ga} if not restricted below. • Equipotential bonding shall be installed inside and outside the hazardous area along the cable for supply and data. • Float usage: - Metallic floats may only be used if they have a weight offset (asymmetric weight distribution). - Metallic floats on non-metallic pipes may not be used. - Aluminum floats may not be used. • Plastic floats may only be installed in hazardous areas which require apparatus of category 1G (for zone 0} with explosion group IIA. Plastic floats may not be used on non-metallic pipes. • Sensors of type USTDII with fill tube hanger (inside the tank) are not ATEX approved for hazardous areas. MTS Sensors 1 Level Plus® Liquid-Level Sensors - M-Series Model USTDII Digital Transmitter Brief Operation Manual for Safe Use, Document Number: 551412 Revision A, 04/13 (US) Safety Instructions INTENDED USE Model USTDII Brief Operation Manual for Safe Use Model Number Identification Model number configuration TRANSMITTER MODEL = U S T D I I 1-6 M-Series Model USTDII liquid-level transmitter UNIT OF MEASURE M = Metric (millimeters) U = US Customary (inches) = TRANSMITTER ORDER LENGTH = Model Number Identification Length Code Millimeters = XXXX (737 mm to 3785 mm) Inches = 0XXX (29 in. to 149 in.) MOUNTING AND CATEGORY OF APPARATUS H A 6 S 9 7 7 = Fill tube mounting (hanger with centering spacers) FM Approved = Flange mounting (¾ in. MNPT adjustable fitting) FM Approved = Flange mounting (¾ in. MNPT adjustable fitting) ATEX Approved MOUNTING TYPE 8 - 11 = 12 = 13 = Standard product without cable (FM Approved) = Standard product without cable (ATEX Approved) = Cable gland and integral blue cable (ATEX Approved) STANDARD FEATURES Five DT's, evenly spaced Data output format (USTD type) USTDII CABLE ASSEMBLY OPTION Description Part number 5 m straight connector cable (ATEX) 2 m straight connector cable (FM) 2 m 90° connector cable (FM) 402486 530049 370481 Level Plus® Liquid-Level Sensors - M-Series Model USTDII Digital Transmitter Brief Operation Manual for Safe Use, Document Number: 551412 Revision A, 04/13 (US) 2 MTS Sensors Model USTDII Brief Operation Manual for Safe Use Marking & Entity Parameters Marking Model Mounting and category of apparatus (12) USTDII 6 Table 1. Mounting type (13) 7, 9 ATEX Marking II 1/2 G EEx ia IIB T4 Approval marking Entity Parameters Entity parameters ATEX Ui = 28 Vdc Model Number Identification ∑li = 200 mA Ci = Negligibly low Li = Negligibly low Table 2. USTDII entity parameters Total power consumption ∑Pi Ambient temperature at the electronics 1.3 W -20 to +40 °C (electronics) 1.2 W -20 to +60 °C (electronics) 1.0 W -20 to +80 °C (electronics, functionality up to 71 °C) - -40 to +125 °C (sensing element) - -40 to 105 °C (temperature sensor) Table 3. MTS Sensors Power and ambient temperature ranges 3 Level Plus® Liquid-Level Sensors - M-Series Model USTDII Digital Transmitter Brief Operation Manual for Safe Use, Document Number: 551412 Revision A, 04/13 (US) Model USTDII Brief Operation Manual for Safe Use Basic Wiring IS Installation HAZARDOUS LOCATION ( II 1/2 G resp II 2 G EEx ia IIB T4 resp EEx ia IIA T4) NON HAZARDOUS LOCATION SAFETY 24-26 Vdc + BARRIER 0.22 mm2 OR HEAVIER TWISTED PAIR CABLE WITH SHIELD SEE NOTE 2 SEE NOTE 1 COMMON − EARTH GROUND (SEE NOTE 4) RX/TX− SAFETY BARRIER SEE NOTE 1 0.22 mm2 OR HEAVIER TWISTED PAIR CABLE WITH SHIELD SEE NOTE 3 SAFETY BARRIER SEE NOTE 1 NON HAZARDOUS AREA +24 Vdc 24 Vdc COMMON TRANS. PROT. EARTH GROUND (SEE NOTE 4) RX/TX+ GROUND RX/TX− Basic Wiring RX/TX + SEE NOTE 6 TANKSIDE EARTH GROUND Figure 1. Safety barrier connections Level Plus® Liquid-Level Sensors - M-Series Model USTDII Digital Transmitter Brief Operation Manual for Safe Use, Document Number: 551412 Revision A, 04/13 (US) 4 MTS Sensors Model USTDII Brief Operation Manual for Safe Use Basic Wiring IS Installation INSTALLATION DRAWING NOTES (FIGURE 1) 1. Safety barriers are ATEX Certified with entity parameters and must be used in an approved configuration where the following conditions are met: • Uo of the barrier combination is less than Ui of the transmitter. • Io of the barrier combination is less than Ii of the transmitter. • Co of the barrier combination is greater than the total Ci of the transmitters plus the cable capacitance. • Lo of the barrier combination is greater than the total Li of the transmitters plus the cable capacitance. Transmitter entity parameters: • Ui = 28 Vdc • ∑li = 200 mA • Ci = negligibly low • Li = negligibly low 2. Power supply cable must be 0,22 mm2 or heavier (e.g. 1.32 mm2 AWG 16), shielded twisted pair cable. Cable capacitance must be less than 160 pF/m. Cable shield is connected to system ground at safety barrier end only. 3. Communications cable must be 0.22 mm2 or heavier (e.g. 1.32 mm2 AWG 16), shielded twisted pair cable. Cable capacitance must be less than 160 pF/m. Cable shield is connected to system ground at safety barrier end only. 4. The wire connection between earth ground and the safety barrier ground terminal must be less than 1 ohm. 5. Maximum approved number of DDA or MODBUS gauges for intrinsically safe wiring networks is 6 to 8. Contact factory for Modbus applications. 6. Connection to earth ground for transient protection circuitry. 7. Ground screw earthing hardware provided to connect gauge housing to earth ground. 8. The transducer frame shall be grounded to earth ground directly or through the equipment on which it is mounted and shall be at the same potential as the safety barrier ground electrode. 9. Electronic equipment connected to associated apparatus must not use or generate more than 250 volts RMS. 10. Cable sets that are run together must have sufficient insulation to withstand 250 volts RMS between sets. 11. All wiring must meet the local regulations and/or other national/international standards. Wiring connections Wiring diagram Gray White Brown Blue Black Figure 2. MTS Sensors Color Signal Blue 24 Vdc Power Black 0 Vdc Power Gray Earth ground Brown TXD RXD + White TXD RXD - NEMA housing with terminal strip or integral cable 5 Level Plus® Liquid-Level Sensors - M-Series Model USTDII Digital Transmitter Brief Operation Manual for Safe Use, Document Number: 551412 Revision A, 04/13 (US) Basic Wiring Notes: Model USTDII Brief Operation Manual for Safe Use Basic Wiring Safety barrier examples Uo Maximum voltage Io Maximum current Po Maximum power Maximum resistance Number of channels 9001/01-280-165-101 28 Vdc 165 mA 1155 mW 198Ω 1 STAHL 9001/01-280-110-101 28 Vdc 110 mA 770 mW 294Ω 1 MTL 728 28 Vdc 93 mA 651 mW 300Ω 1 MTL 728+ 28 Vdc 93 mA 651 mW 300Ω 1 MTL 7028+ 28 Vdc 93 mA 651 mW 300Ω 1 MTL 7128+ 28 Vdc 93 mA 651 mW 300Ω 1 MTL 7728+ 28 Vdc 93 mA 651 mW 300Ω 1 Uo Maximum voltage Io Maximum current (each channel) Po Maximum power (each channel) Maximum resistance (each channel) Number of channels 8.6 Vdc 10 mA 21.5 mW 963Ω 1 Supplier Type STAHL Table 4. Power supply (+24 Vdc) Supplier Type STAHL 9001/01-086-010-101 STAHL 9002/11-120-024-001 12 Vdc 12 mA 70 mW 1156Ω 2 MTL 764+ 12 Vdc 24 mA 72 mW 1075Ω 2 Basic Wiring Table 5. Communication lines (TX/RX+ and TX/RX-) Level Plus® Liquid-Level Sensors - M-Series Model USTDII Digital Transmitter Brief Operation Manual for Safe Use, Document Number: 551412 Revision A, 04/13 (US) 6 MTS Sensors Model USTDII Brief Operation Manual for Safe Use Accessories Floats Model USTDII transmitters should be used with a float having an offset weight and made of stainless steel or Hastelloy C. This allows the float to stay in contact with the pipe to prevent the buildup of electrostatic charge. For detailed information about floats, refer to the ‘Accessories Catalog’, MTS part number 551103. Non-metalic floats with a projected surface area of less than 5,000 mm² should only be used in Zone 0, Gas group IIA such as float part numbers 201643-2, 201649-2, 201650-2, 201109, 251115 and 251116. All other non-metallic floats offered by MTS such as, 251939, 251119, 251120 and 252999, should not be used in a hazardous area application. NITROPHYL FLOATS Float and dimension reference Projected surface area 18 mm (.07 in.) dia. Part number 201643-2 CL Magnet 76 mm (3 in.) 2356 mm² 201649-2 Added weight for interface floats 201650-2 31 mm (1.2 in.) dia. TEFLON FLOATS Float and dimension reference Projected surface area 9 mm (0.35 in.) 18 mm (0.7 in.) dia. Part number 201109 Centerline of Magnet 4635 mm² 251116 61 mm (2.38 in.) dia. MTS Sensors 251115 7 Level Plus® Liquid-Level Sensors - M-Series Model USTDII Digital Transmitter Brief Operation Manual for Safe Use, Document Number: 551412 Revision A, 04/13 (US) Accessories Magnet 76 mm (3 in.) Agency Model USTDII Brief Operation Manual for Safe Use EC Declaration of Conformity Level Plus® Liquid-Level Sensors - M-Series Model USTDII Digital Transmitter Brief Operation Manual for Safe Use, Document Number: 551412 Revision A, 04/13 (US) 8 MTS Sensors Document Part Number: 551412 Revision A, 04/13 (US) MTS, Temposonics and Level Plus are registered trademarks of MTS Systems Corporation. All other trademarks are the property of their respective owners. Printed in USA. Copyright © 2013 MTS Systems Corporation. All Rights Reserved in all media. All specifications are subject to change. Contact MTS for specifications and engineering drawings that are critical to your application. Drawings contained in this document are for reference only. Go to http://www.mtssensors.com for the latest product information. ® SENSORS MTS Systems Corporation Sensors Division MTS Sensor Technologie GmbH & Co. KG MTS Sensors Technology Corporation 3001 Sheldon Drive Cary, North Carolina, 27513, USA Tel.: +1-800-633-7609 Fax: +1-919-677-2343 +1-800-498-4442 e-mail: sensorsinfo@mts.com http://www.mtssensors.com Auf dem Schüffel 9 D - 58513 Lüdenscheid, Germany Tel.: +49-2351-9587-0 Fax: +49-2351-56491 737 Aihara-cho, Machida-shi Tokyo 194-0211, Japan Tel.: +81-42-775-3838 Fax: +81-42-775-5516 e-mail: info@mtssensor.de http://www.mtssensor.de e-mail: info@mtssensor.co.jp http://www.mtssensor.co.jp