Ausgabe / Edition: AC 477 752 4070 76 J AC-74
SBR - Sensor Board Resolver
Contents
2
3
4
5
0
1
Definitions and Warnings.............................................................................................. 0-1
Description ..................................................................................................................... 1-1
Technical Data................................................................................................................ 2-1
Installation ...................................................................................................................... 3-1
Connecting-up................................................................................................................ 4-1
Start-up ........................................................................................................................... 5-1
Siemens AG 477 752 4070 76 J AC-74
SIMOVERT MASTERDRIVES Operating Instructions
SBR - Sensor Board Resolver Definitions and Warnings
Qualified personnel
!
!
For the purpose of this documentation and the product warning labels, a
"Qualified person" is someone who is familiar with the installation, mounting, start-up, operation and maintenance of the product. He or she must have the following qualifications:
♦
Trained or authorized to energize, de-energize, ground and tag circuits and equipment in accordance with established safety procedures.
♦
Trained or authorized in the proper care and use of protective equipment in accordance with established safety procedures.
♦
Trained in rendering first aid.
For the purpose of this documentation and the product warning labels,
"Danger" indicates death, severe personal injury or substantial property damage will result if proper precautions are not taken.
For the purpose of this documentation and the product warning labels,
"Warning" indicates death, severe personal injury or property damage can result if proper precautions are not taken.
Siemens AG 477 752 4070 76 J AC-74
SIMOVERT MASTERDRIVES Operating Instructions 0-1
Definitions and Warnings
!
!
SBR - Sensor Board Resolver
For the purpose of this documentation and the product warning labels,
"Caution" indicates that minor personal injury or material damage can result if proper precautions are not taken.
For the purpose of this documentation, "Note" indicates important information about the product or about the respective part of the documentation which is essential to highlight.
♦
Hazardous voltages are present in this electrical equipment during operation.
♦
Non-observance of the warnings can thus result in severe personal injury or property damage.
♦
Only qualified personnel should work on or around the equipment
♦
This personnel must be thoroughly familiar with all warning and maintenance procedures contained in this documentation.
♦
The successful and safe operation of this equipment is dependent on correct transport, proper storage and installation as well as careful operation and maintenance.
477 752 4070 76 J AC-74 Siemens AG
Operating Instructions SIMOVERT MASTERDRIVES 0-2
SBR - Sensor Board Resolver
!
Definitions and Warnings
Components which can be destroyed by electrostatic discharge (ESD)
The board contains components which can be destroyed by electrostatic discharge. These components can be easily destroyed if not carefully handled.
If you have to handle electronic boards, please observe the following:
♦
Electronic boards should only be touched when absolutely necessary.
♦
The human body must be electrically discharged before touching an electronic board.
♦
Boards must not come into contact with highly insulating materials - e.g.
plastic parts, insulated desktops, articles of clothing manufactured from manmade fibers.
♦
Boards must only be placed on conductive surfaces.
♦
Boards and components should only be stored and transported in conductive packaging (e.g. metalized plastic boxes or metal containers).
♦
If the packing material is not conductive, the boards must be wrapped with a conductive packaging material, e.g. conductive foam rubber or household aluminium foil.
Siemens AG 477 752 4070 76 J AC-74
SIMOVERT MASTERDRIVES Operating Instructions 0-3
Definitions and Warnings SBR - Sensor Board Resolver
The necessary ESD protective measures are clearly shown in the following diagram:
♦
a = Conductive floor surface
♦
b = ESD table
♦
c = ESD shoes
♦
d = ESD overall
♦
e = ESD chain
♦
f = Cubicle ground connection d b d e f a c
Sitting
Fig. 0-1 ESD protective measures f c
Standing a f f b d e c a
Standing / Sitting f
0-4
477 752 4070 76 J AC-74 Siemens AG
Operating Instructions SIMOVERT MASTERDRIVES
SBR - Sensor Board Resolver Description
NOTE
The SBR optional board (Sensor Board Resolver) enables a resolver to be connected to the converter and inverter modules.
The SBR optional board is available in two versions:
♦ SBR1
♦
SBR2
Optional board for connecting up a resolver
Optional board for connecting up a resolver with additional pulse encoder simulation
Connectable resolvers
Temperature sensor
You can connect all standard 2-pole resolvers and resolvers with the pole pair number of the motor to the optional board. Adaptation to the different types of resolvers is effected on the optional board by automatic adjustment of the signal amplitude and the sampling time.
As well as a resolver, you can connect a temperature sensor (either a KTY or a
PTC sensor) to the optional board for monitoring the motor temperature.
Siemens AG 477 752 4070 76 J AC-74
SIMOVERT MASTERDRIVES Operating Instructions 1-1
Description
Pulse encoder simulation
SBR - Sensor Board Resolver
As an option, the SBR2 optional board can be equipped with pulse encoder simulation. This provides A+, A-, B+, B-, zero+ and zero- signals according to the standard RS422 which can be picked up via an additional front socket.
System connector
Fixing screw
Fig. 1-1 View of the SBR2
Fixing screw
25-pole Sub-D connection
Resolver with KTY/PTC
Pulse encoder simulation
(only on SBR2)
1-2
477 752 4070 76 J AC-74 Siemens AG
Operating Instructions SIMOVERT MASTERDRIVES
SBR - Sensor Board Resolver
Function principle
Description
The position of an exciter coil in the rotor in relation to two stator coils is evaluated in the resolver.
A high-frequency carrier signal (5 to 10 kHz) is injected into the rotor winding of the resolver via a rotary transformer. The high-frequency current flowing in the rotor induces a high-frequency voltage into the two stator coils arranged at right-angles to each other. The amplitude of this voltage depends on the present position of the rotor winding or of the rotor. The envelope curve of the voltage induced into the stator coils is a sine or cosine curve.
On account of the right-angle arrangement of the stator coils, one coil will supply the sine value, and the other coil the cosine value of the present rotor position. Both signals are sensed via A/D transformers.
Subsequently, the unit software calculates the position angle
α from these two signals via trigonometry functions.
The change of the position angle
α
between two sampling times provides the current speed of the motor.
Siemens AG 477 752 4070 76 J AC-74
SIMOVERT MASTERDRIVES Operating Instructions 1-3
Description
SBR - Sensor Board Resolver
Fig. 1-2 Schematic diagram of a resolver
1-4
477 752 4070 76 J AC-74 Siemens AG
Operating Instructions SIMOVERT MASTERDRIVES
SBR - Sensor Board Resolver
Description
Fig. 1-3 Resolver output signals
Siemens AG 477 752 4070 76 J AC-74
SIMOVERT MASTERDRIVES Operating Instructions
1-5
Description
Adjustment
SBR - Sensor Board Resolver
Via a PLL control loop, the SBR optional board is capable of setting the phase position of the exciter signal such that the sine or cosine signal induced in the stator windings of the resolver is always sensed at maximum.
At the same time, the amplitude of the exciter signal is adjusted to the maximum resolution of the internal A/D transformer. This enables the position angle of the stator winding to be sensed with the maximum possible accuracy.
1-6
477 752 4070 76 J AC-74 Siemens AG
Operating Instructions SIMOVERT MASTERDRIVES
SBR - Sensor Board Resolver
Order numbers
Size (length x width)
Pollution degree
6SE7090-0XX84-0FB0 (SBR1)
Resolver evaluation without pulse encoder simulation
6SE7090-0XX84-0FC0 (SBR2)
Resolver evaluation with pulse encoder simulation
90 mm x 83 mm
Pollution degree 2 acc. to IEC 664-1 (DIN VDE 0110/T1), moisture condensation is not permissible in operation
Acc. to DIN IEC 68-2-6 (for correctly installed board) Mechanical strength
During stationary operation
- Deflection
- Acceleration
During transport
- Deflection
- Acceleration
Climate class
Type of cooling
0.15 mm in frequency range 10 Hz to 58 Hz
19.6 m/s² in frequency range > 58 Hz to 500 Hz
3.5 mm in frequency range 5 Hz to 9 Hz
9.8 m/s² in frequency range > 9 Hz to 500 Hz
Class 3K3 to DIN IEC 721-3-3 (in operation)
Natural-air cooling
Technical Data
Siemens AG 477 752 4070 76 J AC-74
SIMOVERT MASTERDRIVES Operating Instructions 2-1
Technical Data
Permissible ambient or coolant temperature
- during operation
- during storage
- during transport
Permissible humidity rating
SBR - Sensor Board Resolver
0° C to +70° C (32° F to 158° F)
-25° C to +70° C (-13° F to 158° F)
-25° C to +70° C (-13° F to 158° F)
Relative air humidity
≤
95 % during transport and storage
≤
85 % in operation (condensation not permissible)
Table 2-1 Technical Data
2-2
477 752 4070 76 J AC-74 Siemens AG
Operating Instructions SIMOVERT MASTERDRIVES
SBR - Sensor Board Resolver Installation
NOTE
If the inverters/converters are ordered with optional functions, the optional boards are already installed in the units when they are delivered.
It is possible to retrofit optional boards and this can be carried out by the user.
For this purpose, there are either three or up to six slots on the basic unit depending on the unit type of construction for mounting the optional boards.
An exact description of installation is included with the relevant basic unit. As the unit has to be removed and opened in order to install optional boards, attention must be paid to the ESD measures. Please refer to the operating instructions of the basic unit in this regard.
Install the SBRx optional board in slot C. The SBRx optional board does not operate in other slots.
Siemens AG 477 752 4070 76 J AC-74
SIMOVERT MASTERDRIVES Operating Instructions 3-1
SBR - Sensor Board Resolver Connecting-up
Connecting-up The optional board is provided with the following connections for the signal cables:
♦
X414Encoder connection via a 25-pole SUB D connector
♦
X410Pulse encoder simulation via a 6-pole terminal strip (only for SBR2)
Connect the shielded signal cables to the appropriate connection and place the shield on the shield plate.
Siemens AG 477 752 4070 76 J AC-74
SIMOVERT MASTERDRIVES Operating Instructions 4-1
Connecting-up
Encoder connection
13
1
25
14
SBR - Sensor Board Resolver
Connect the resolver to the optional board by means of the shielded encoder cable. Use the pre-assembled cable for this purpose.
Connection is via a 25-pole SUB D connector on the front side of the optional board.
Pin
7
8
9
11
5
6
3
4
13
24
25
Housing
Significance
Resolver output voltage sin+
Resolver output voltage sin-
Internal shield for 3 and 4
Resolver output voltage cos+
Resolver output voltage cos-
Internal shield for 6 and 7
Resolver excitation +
Ground for resolver excitation
Motor temperature sensing PTC/KTY
Internal shield for 13 and 25
Motor temperature sensing PTC/KTY
External shield
Range adjustable 0-7 V
SS
5 to 10 kHz sine
,
Table 4-1 Pin assignment at connection X414
4-2
477 752 4070 76 J AC-74 Siemens AG
Operating Instructions SIMOVERT MASTERDRIVES
SBR - Sensor Board Resolver
Pulse encoder simulation
(only for SBR2)
Connecting-up
At connection X410 you can pick up the signals of the pulse encoder simulation generated on the optional board.
The optional board generates 512 or 1024 pulses alternatively per electrical revolution. In the case of a two-pole resolver the set pulses (512 or 1024) are generated accordingly, in the case of a four-pole resolver twice the number of pulses are generated, and in the case of a six-pole resolver, three times the number of pulses are generated per mechanical resolver revolution.
The simulation signals are available as differential signals according to standard RS 422.
Terminal Designation
90
91
92
93
94
95
A+
A-
B+
B-
N+
N-
Significance
Pulse encoder simulation track A+
Pulse encoder simulation track A-
Pulse encoder simulation track B+
Pulse encoder simulation track B-
Pulse encoder simulation track zero+
Pulse encoder simulation track zero-
Connectable cross-section: 0.5 mm² (AWG 20)
Terminal 90 is at the top when installed.
Table 4-2 Terminal assignment at connection X410
Range
RS 422 standard
RS 422 standard
RS 422 standard
Siemens AG 477 752 4070 76 J AC-74
SIMOVERT MASTERDRIVES Operating Instructions 4-3
SBR - Sensor Board Resolver Start-up
NOTE
After installation of the SBR optional board has been completed, an automatic self-test is carried out when the basic unit (converter/inverter) is powered up.
Please refer to the documentation for the respective basic unit regarding instructions for parameterization using the quick procedure.
Siemens AG 477 752 4070 76 J AC-74
SIMOVERT MASTERDRIVES Operating Instructions 5-1
Bisher sind folgende Ausgaben erschienen:
The following editions have been published so far:
Ausgabe
Edition
Interne Sachnummer
Internal Item Number
AA 477 752 4070 76 J AA-74
AB 477 752 4070 76 J AB-74
AC 477 752 4070 76 J AC-74
Ausgabe AC besteht aus folgenden Kapiteln:
Version AC consists of the following chapters:
Kapitel Chapter Seitenzahl
Pages
Ausgabedatum
Version date
0 Definitionen und Warnungen Definitions and Warnings 4 09.98
1 Beschreibung Description 6 09.98
2 Technische Daten Technical Data 2 09.98
3 Montage Installation 1 09.98
4 Anschließen Connecting-up 3 09.98
5 Inbetriebsetzung Start-up 1 09.98
Group: Automation and Drives (A&D)
Division: Variable-Speed Drive Systems
Postfach 3269, D-91050 Erlangen
Siemens Aktiengesellschaft
Subject to change Printed in the Federal Republic of Germany