SmartPV Advanced Power Integrated Stations A complete set of integration possibilities for your project’s needs wherever it is placed. 28 THE QUICKEST OPTION TO INTEGRATE ENERGY INTO THE GRID 80 MW Horus I+II Plants in Guatemala with APIS 2200 The biggest operating in Central America 29 TURNKEY SOLUTIONS TO MEET THE THE MOST DEMANDING GRID CODE REQUIREMENTS Complete solutions designed for utility-scale plants that operate under extreme conditions. They integrate all needed to plug and play the entire conversion stage from Pv Panels to the MV grid. each project. 30 FLEXIBLE PHILOSOPHY FOR SOLID SOLUTIONS Depending on the integration, tthe SmartPV APIS include GPTech inverters of the SmartPV inverters serie, Low and Medium Voltage Protections and auxiliary, Medium Voltage Transformer with protection cells and fence, fulfilling all legal requirements and optimised to the technical needs. These devices offer remote control of active and reactive power, as well as ramp rate response guaranteeing the grid stability 31 SmartPV APIS UL APIS1200-UL / APIS1500-UL / APIS1750-UL Optimised Designs for the USA Market APIS UL-i20 Mechanical characteristics Inverter Power Module dimensions (H / W / D) 2100 x 2000 x 780 mm / 82,67 x 78,74 x 30,70 in Inverter Disconnection Module dimensions (H / W / D) 2100 x 1100 x 750 mm / 82,67 x 43,3 x 29,52 in Container dimensions (H / W / D) 2900 x 6000 X 2440 mm / 20’ x 8’ x 9’6” Weight (5) 8396 kg / 18510 Ibs Maximum fresh air consumption 8000 (2 x 4000) m3/h Environment rating NEMA 3R, IP54 Medium Voltage Stage Transformer Pad Mounted Protections 2 x GPTech GPDM -I APIS UL-skd Mechanical characteristics Inverter Power Module dimensions (H / W / D) 2300 x 2000 x 845 mm / 90,55 x 78,74 x 30,70 in Inverter Disconnection Module dimensions (H / W / D) 2162 x 1100 x 750 mm / 85,12 x 43,3 x 29,52 in Skid dimensions (H / W / D) 2522 X 9000 x 2100 mm / 99,3 x 354,4 x 82,7 in Weight (5) 12000 kg / 26455 Ibs Maximum fresh air consumption 12000 (2 x 6000) m3/h Environment rating NEMA 3R, IP54 Medium Voltage Stage 32 Transformer Pad Mounted Protections 2 x GPTech GPDM -O APIS 1200-UL APIS 1500-UL APIS 1750-UL 395 - 825 Vdc 495 - 825 Vdc 585 - 825 Vdc DC Input Voltage range (MPPT) (1) MPPT Inputs 2 Maximum DC voltage 1000 Vdc Maximum input current 3060 A DC inputs (optional external box) 2 0-40 (2x10 - 2x20). Protected by fuses AC Output Transformer output. Medium AC voltage(5) 24 kV Frequency rated 50/60 Hz Frequency operation range 47 - 63 Hz Rated AC power @ 50oC 1,12 (2 x 0,56) MVA 1,4 (2 x 07) MVA 1,66 (2 x 0,83) MVA Rated AC power @ 25oC 1,2 (2 x 0,6) MVA 1,5 (2 x 0,75) MVA 1,78 (2 x 0,89) MVA Rated AC power @ 50oC and PF of 0,9 1,0 (1 x 0,5) MW 1,26 (2 x 0,63) MW 1,5 (2 x 0,75) MW Inverter output. Maximum output current 2900 (2 x 1450) A Total Harmonic Distortion (THD) <3% Power Factor at rated power adjustable (0.9 inductive ... 0.9 capacitive) Galvanic insulation Yes Efficiency Maximum European efficiency (2) 97,29% 97,72% 98,00% Maximum CEC effienciy (3) 97,18% 97,63% 97,92% Inverter self-consumption at night Inverter self-consumption in operation (4) <=400 (2 x 200) W <= 6 (2 x 3) kVA Ambient conditions Operation temperature -4oF/140oF (-20oC/60oC) Operation ambient temperature (without derating) -4oF/122oF (-20oC/50oC) Storage and transport temperature -22oF/149oF (-30oC/65oC) Maximum relative humidity 95% without condensation Maximum altitude above the sea level 3000 m AC Protections Inverter output AC overvoltage protection Class II Anti-islanding Yes Grid voltage variations Yes Frequency failures Yes Asymmetric currents Yes Low Voltage Ride Through (LVRT) Capability Yes DC Protections DC overvoltage protection Inverter shutting down on overload error PV-field isolation detector Panel Disconnnection Capability Class II Yes Yes Yes. Contactor Other Protections Breaker protections of auxiliary systems Yes Auxiliary systems overvoltage protection Yes Power Control Features Reactive control by external signal Reactive control by internal configuration Reactive injection in LVRT Over frequency active power response Ramp rate control External power limitation Yes Yes. Timetable PF configuration or voltage dependent function Yes. Three different operation modes Yes. Configurable droop Yes. Under irradiance value restriction Yes. Control allows continuous limit values Interfaces Touch-HMI Yes MODBUS RTU communication protocol Yes Field bus connection with RS485 Yes Luminous indicator, start/stop control and emergency stop Remote monitoring system, with GSM/GPRS modem Yes Optional Legal standards UL1741 (6) Yes United States - UL Listing Mark Yes Canada - cUL Listing Mark Yes IEEE 1547 Yes CSI/CEC Performance Testing (California) Yes IEC 62109-1, IEC 62109-2 Yes Notes 1. At VAC, nom and cosφ= 1 2. Inverter self-consumption is not considered in the efficiency measurement. Medium voltage transformer is not considered in the efficiency measurement (Typical transformer efficiency > 99%) 3. Self-consumption at rated operation 4. Self-consumption in inverters is not considered in the efficiency measurement. A 33kV/240-300-355-430V transformer is considered 5. Estimated. Customized MV transformer configuration 6. For UL certification, please, consult special sales conditions 33 SmartPV APIS International APIS1200-INT / APIS1500-INT / APIS1750-INT Extended Range to meet all the requirements APIS INT-i20 Mechanical characteristics Inverter Power Module dimensions (H / W / D) Container dimensions (H / W / D) 2100 x 2000 x 780 mm / 82,67 x 78,74 x 30,70 in 2900 x 6000 X 2440 mm / 8’ x 20’ x 9’6” Weight 8396 kg / 18510 Ibs Maximum fresh air consumption 8000 (2 x 4000) m3/h Environment rating NEMA 3R, IP54 Medium Voltage Stage Transformer Pad Mounted / Oil -Outdoor Protections 2 x GPTech GPDM -I APIS INT-skd Mechanical characteristics Inverter Power Module dimensions (H / W / D) 2300 x 2000 x 845 mm / 90,55 x 78,74 x 30,70 in Inverter Disconnection Module dimensions (H / W / D) 2162 x 1100 x 750 mm / 85,12 x 43,3 x 29,52 in Skid dimensions (H / W / D) 2522 X 9000 x 2100 mm / 99,3 x 354,4 x 82,7 in Weight 12000 kg / 26455 Ibs Maximum fresh air consumption 12000 (2 x 6000) m3/h Environment rating NEMA 3R, IP54 Medium Voltage Stage 34 Transformer Pad Mounted / Oil -Outdoor Protections 2 x GPTech GPDM -O A complete set of integration options APIS INT-i40 Mechanical characteristics Inverter Power Module dimensions (H / W / D) Container dimensions (H / W / D) 2100 x 2000 x 780 mm / 82,67 x 78,74 x 30,70 in 2900 x 12000 X 2440 mm / 8’ x 40’ x 9’6” Weight 17530 kg / 38647 Ibs Maximum fresh air consumption 8000 (2 x 4000) m3/h Environment rating NEMA 3R, IP54 Medium Voltage Stage Transformer Pad Mounted / Oil -Outdoor Protections up to 4 x GPTech GPDM -I 35 APIS 1200-INT APIS 1500-INT APIS 1700-INT 375 - 825 Vdc 455 - 825 525 – 825 Vdc DC Input Voltage range (MPPT) Maximum DC voltage 1000 Vdc Maximum input current 3800 A Fused DC inputs (optional external box) 2 0-40 (2x10 - 2x20) Number of MPPT inputs 2 AC Output Rated AC power @ 50oC2 1120 kVA 1400 kVA 1660 kVA Rated AC power @ 35oC2 1200 kVA 1500 kVA 1780 kVA Nominal AC voltage Customizable. Standard voltages. 11kV; 13. kV; 15 kV; 20 kV; 22.9 kV;33 kV;34.5 kV Transformers taps Customizable. Standards ±2.5%,±5% Transformer Vector Group Customizable. Standards. Ynd11d11; Dy11y11 Frequency rated 50/60 Hz Frequency operation range 47 - 63 Hz Power Factor at rated power Full range adjustable Cooling type ONAN/KNAN Output MV Maneuver T-Blade. Bayonet fuses. Efficiency Maximum European efficiency3 97.01% 97.16% Maximum CEC effienciy3 97.14% 97.30% Internal consumption at nigh (Inv. / MV transformer) (W)4 Internal consumption in operation (Inv. / APIS Aux. services) (W)5 <=400 (2 x 200) W / <2400 W <=400 (2 x 200) W / <3000 W <= 6000 (2 x 3000) W / <2100 W Ambient Conditions Operation temperature -4oF/140oF (-20oC/55oC) Operation ambient temperature (without derating) -4oF/113oF (-20oC/45oC) Storage and transport temperature -22oF/149oF (-30oC/65oC) Maximum relative humidity 95% without condensation Maximum altitude above the sea level 3000 m AC Protections Inverter output AC overvoltage protection Yes Anti-islanding Yes Grid voltage variations Yes Frequency failures Yes Asymmetric currents Yes Low Voltage Ride Through (LVRT) Capability Yes DC Protections DC overvoltage protection Yes Inverter shutting down on overload error Yes PV-field isolation detector Panel Disconnnection Capability Yes Yes. DC Contactor Other Protections Breaker protections of auxiliary systems Yes Auxiliary systems overvoltage protection Yes Power Control Features Reactive control by external signal Reactive control by internal configuration Reactive injection in LVRT Over frequency active power response Ramp rate control External power limitation APIS Controller Yes Yes. Timetable PF configuration or voltage dependent function Yes. Three different operation modes Yes Yes. Under irradiance value restriction Yes. Control allows continuous limit values Optional. See specifications Interfaces Touch-HMI Yes MODBUS RTU communication protocol Yes Field bus connection with RS485 Remote monitoring system, with GSM/GPRS modem Yes Optional Legal standards NEC 2011 Yes United States - UL 1741 Listing Mark6 Yes, Certification in process Canada - cUL Listing Mark6 Yes, Certification in process IEEE 15476 Yes, Certification in process CSI/CEC Performance Testing (California)6 Yes, Certification in process IEC 62109-1, IEC 62109-2 Yes Notes 1. Estimated. Customized MV transformer configuration 2. At VAC, nom and cosφ= 1 3. Inverter self-consumption is not considered in the efficiency measurement. Medium voltage transformer is not considered in the efficiency measurement (Typical transformer efficiency > 99%) 4. Self-consumption at rated operation 5. Self-consumption in inverters is not considered in the efficiency measurement. reference transformer values: 33kV/240-300-355-430V 6. For UL certification, please, consult special sales conditions 36 97,23% 97,38% <=400 (2 x 200) W / <3400 W APIS 1900-INT APIS 2200-INT APIS 3300-INT APIS 4400-INT 580 – 825 Vdc DC Input Voltage range (MPPT) 525 – 825 Vdc 580 – 825 Vdc 580 – 825 Vdc 1000 Vdc 1000 Vdc 1000 Vdc 3800 A 5700 A 7600 A 2 0-40 (2x10 - 2x20) 30-60 (3x10 - 3x20) 40-80 (4x10 - 4x20) 2 3 4 Maximum DC voltage Maximum input current Fused DC inputs (optional external box) Number of MPPT inputs AC Output Rated AC power @ 50oC2 1780 kVA 2010 kVA 3015 kVA 4020 kVA Rated AC power @ 35oC2 1900 kVA 2150 kVA 3225 kVA 4300 kVA Nominal AC voltage Customizable. Standard voltages. 11kV; 13. kV; 15 kV; 20 kV; 22.9 kV;33 kV;34.5 kV Transformers taps Customizable. Standards ±2.5%,±5% Transformer Vector Group Customizable. Standards. Ynd11d11; Dy11y11 Frequency rated 50/60 Hz Frequency operation range 47 - 63 Hz Power Factor at rated power Full range adjustable Cooling type ONAN/KNAN Output MV Maneuver T-Blade. Bayonet fuses. Efficiency Maximum European efficiency3 97,23% 97.30% 98.45% Maximum CEC effienciy3 97,38% 97.50% 98.49 Internal consumption at nigh (Inv. / MV transformer) (W)4 Internal consumption in operation (Inv. / APIS Aux. services) (W)5 <=400 (2 x 200) W / <3800 W <=400 (2 x 200) W / <4400W <=600 (3 x 200) W / <5000W <= 6000 (2 x 3000) W / <2100 W <= 9000 (3 x 3000) W/<2100W 98.45% 98.49 <=800 (4 x 200) W / <5600W <= 12000 (4 x 3000)W/<2100W Ambient Conditions Operation temperature -4oF/140oF (-20oC/55oC) Operation ambient temperature (without derating) -4oF/113oF (-20oC/45oC) Storage and transport temperature -22oF/149oF (-30oC/65oC) Maximum relative humidity 95% without condensation Maximum altitude above the sea level 3000 m AC Protections Inverter output AC overvoltage protection Yes Anti-islanding Yes Grid voltage variations Yes Frequency failures Yes Asymmetric currents Yes Low Voltage Ride Through (LVRT) Capability Yes DC Protections DC overvoltage protection Yes Inverter shutting down on overload error Yes PV-field isolation detector Yes Panel Disconnnection Capability Yes. DC Contactor Other Protections Breaker protections of auxiliary systems Yes Auxiliary systems overvoltage protection Yes Power Control Features Reactive control by external signal Yes Reactive control by internal configuration Yes. Timetable PF configuration or voltage dependent function Reactive injection in LVRT Yes. Three different operation modes Over frequency active power response Yes Ramp rate control Yes. Under irradiance value restriction External power limitation Yes. Control allows continuous limit values APIS Controller Optional. See specifications Interfaces Touch-HMI Yes MODBUS RTU communication protocol Yes Field bus connection with RS485 Yes Remote monitoring system, with GSM/GPRS modem Optional Legal standards NEC 2011 Yes United States - UL 1741 Listing Mark6 Yes Canada - cUL Listing Mark6 Yes, Certification in process IEEE 15476 Yes, Certification in process CSI/CEC Performance Testing (California)6 IEC 62109-1, IEC 62109-2 Yes, Certification in process Yes Notes 1. Estimated. Customized MV transformer configuration 2. At VAC, nom and cosφ= 1 3. Inverter self-consumption is not considered in the efficiency measurement. Medium voltage transformer is not considered in the efficiency measurement (Typical transformer efficiency > 99%) 4. Self-consumption at rated operation 5. Self-consumption in inverters is not considered in the efficiency measurement. reference transformer values: 33kV/240-300-355-430V 6. For UL certification, please, consult special sales conditions 37 APIS CONTROLLER APIS CONTROLLER GPTech APIS Controller has become a key solution for the generation units integration for any modern renewable and hybrid power plant. The solution is based on open standards: • Preventing the lock in by a specific technology and/or vendor • Enabling an easy integration of the solution with third-party applications Customized features to fully reach customer’s requirements in the most effective and reliable way. MODULAR DESIGNED WITH ADVANCE COMMUNICATION AND CONTROL FEATURES ADAPTED TO EACH FACILITY Some Available Control Features Dynamic closed-loop System Soft start Soft shutdown Error/Alarm Handling Power Transformer MV Swtichgear Converters Communications Error Auxiliaty Systems Temperature Control APIS Fan Control Power Transformer Derating Converter Derating Humidity Control Solar Inverter Controls Energy efficiency strategies Round-Robin Scheduling Temperature Derating BPCS+ESS Controls SOC Management Dinamic Active Power Limits Energy efficiency strategies Round-Robin Scheduling STATCOM Controls Energy efficiency strategies Round-Robin Scheduling 38 PVWD DC/AC Disconnection Module PV-GPDM Indoor/Outdoor PVWD -GPDM-I / PVWD-GPDM-O • The PVWD DC/AC Disconnection Module connects all Smart PV Inverters of the PVWD series to the DC and AC side of the PV facility. • The disconnection module contains AC and DC switches in a compact single enclosure separated from inverters and compatible for the whole PVWD familly and the Advanced Power Integrated Stations (APIS). It allows up to 20 DC inputs, guarantying safe emergency disconnection and/or maintenance in compliance with NEC. PV-GPDM DC Swith Maximum input voltage Maximum input current Switch type Maximum short-circuit current 1000 Vdc 1800 A Switch disconnector Up to 100 kA Maximum DC inputs 20 Number of handling switches 1 AC Switch Maximum voltage range Frequency Maximum output current Switch type Max. short-circuit current (1s) Numer of handlers 690 V 50/60 Hz 2000 A Circuit breaker Up to 40 kA 1 General Characteristics Dimensions (H x W x D) Environmental rating Weight 2162 x 1100 x 750 mm / 85,12 x 43,3 x 29,52 inches NEMA 3R 605 Kg / 1331 Ib Operation temperature -4oF / 140oF (-20oC / 60oC) Storage and transport temperature 22oF / 149oF (-30oC / 65oC) Maximum relative humidity Maximum altitude above sea level 95% 3000 m Legal Standards UL1741 Yes United States - UL Listing Mark Yes Canada - UL Listing Mark Yes IEEE 1547 Yes IEC 62109-1, IEC 62109-2 Yes 39