FCA50F

advertisement
FCA50F
R
(LVD)
EMC Compliance
• EN55011-A
• EN61000-4-2
• EN61000-4-3
• EN61000-4-4
• EN61000-4-5
• EN61000-4-6
• EN61000-4-11
High input voltage (AC187~528V)
Peak load possible (at AC240~528V)
DIN Rail Attachment (Optional)
Small size
UL, C-UL recognized, TÜV approved
Three-year warranty
FCA
¡ ORDERING INFORMATION
FCA50F-24Optional:(Ex.with DIN rail attachment:N1)
Output voltage
Universal input
Output wattage
Series name
SPECIFICATIONS
FCA50F-24
MODEL
VOLTAGE
AC187~528V 1º
CURRENT
AC240V
0.55Atyp
AC480V
0.30Atyp
FREQUENCY
INPUT
50/60 (47~63) Hz
EFFICIENCY
INRUSH CURRENT
AC240V
82%typ
AC480V
78%typ
AC240V
25Atyp At cold start (At Room Temperature)
AC480V
50Atyp At cold start (At Room Temperature)
LEAKAGE CURRENT
0.75mA max(60Hz according to IEC60950)
VOLATAGE
[V]
24
CURRENT
[A]
2.1(6.7)¶1
[mV]
LINE REGULATION
240max ¶2
[mVp-p]
-10~0˚C
320max ¶2
RIPPLE NOISE
O~+50˚C
680max ¶2
[mVp-p]
-10~0˚C
720max ¶2
TEMPERATURE
REGULATION [mV]
-10~+50˚C
DRIFT
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
CONSTRUCTION
¶1
¶2
¶3
¶4
¶5
600max
[mV]¶5
100max
START-UP TIME
[ms]
800max(ACIN 240V, Io=100%)
HOLD-UP TIME
[ms]
10typ(ACIN 240V, Io=100%)
OUTPUT VOLATAGE
ADJUSTMENT RANGE
ISOLATION
480max
O~+50˚C
RIPPLE
PROTECTION
CIRCUIT AND
OTHERS
150max
O~6.7A
[mV]
OUTPUT
96max
O~2.1A
LOAD REGULATION
[V]
21.6~26.4
OVERCURRENT PROTECTION
Works over 105% of peak current and recovers automatically
OVERVOLTAGE PROTECTION
Works at 115%~140% of rating
OPERATING INDICATION
LED(GREEN)
INPUT-OUTPUT
AC3,000V, 1minute, Cutoff current=10mA,DC500V 50MΩmin. (AT Room Temperature)
INPUT-FG
AC2,000V, 1minute, Cutoff current=10mA,DC500V 50MΩmin. (AT Room Temperature)
OUTPUT-FG
AC 500V, 1minute, Cutoff current=100mA,DC500V 50MΩmin. (AT Room Temperature)
OPERATING TEMP.,HUMID.
AND ALTITUDE
STORAGE TEMP.,HUMID.
AND ALTITUDE
-10~+70:, 20~90%RH(Non condensing)(Refer to DERATING CURVE), 3,000m(10,000feet)max
VIBRATION
10~55Hz 19.6m/s2(2G), 3 minutes period,60 minutes each along X,Y and Z axis ¶3
IMPACT
196.1m/s2(20G) 11ms, once each X,Y and Z axis ¶3
AGENCY APPROVALS
UL1950,C-UL,EN60950,EN50178
CONDUCTED NOISE
Complies with FCC-A,CISPR11-A, EN55011-A
DIMENSION/WEIGHT
50†125†124mm(W†H†D) ¶4 /630g max
COOLING METHOD
Convection
-20~+75:, 20~90%RH(Non condensing), 9,000m(30,000feet)max
Peak current for 150ms in a 30second period is acceptable.
In case of rated input/output(ACIN240-480v/2.1A), either the 20MHz oscilloscope or the ripple noise meter(equivalent to Keisokugiken:RM101) is used.
Option with DIN rail attachment(N1) is only for direction X(refer to sec4.2 in manual).
Depth of power supply is 132mm with DIN rail attachment.
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25ª, with the input voltage held constant at the rated input/output.
FCA-1
SINGLE OUTPUT
MODEL
OUTPUT
WATTAGE
DC OUTPUT
¡EXTERNAL VIEW
13max
FCA50F-24
50W(160W)
24V 2.1A(6.7A)
( ) Peak
50
30
(11.5)
LED
Voltage Adjust
DIN Rail Attachment
FCA50F-24-N1 only
AC(N)
(35.5)
(116)
(72)
AC(L)
AC(N)
Terminal
Block
(M4)
Spacer
FCA50F-24-N1 only
(7)
7
(34)
AC(L)
125
FG
13
-V
FG
(110)
+V
(102)
+
-
10
FCA50F-24
(15.5)
(24.5)
16
(8)
124
(22)
(12)
119
50
44.5
25.4
71.1±0.5
Terminal Block Cover
FCA
3-M3 Mounting Hole
12.7 25.4±0.5
º3.8
¶Weight : 630g or less
¶Tolerance : ±1
¶Mounting torque : 0.4N•m
(5.0kgf•cm)max
¶Dimensions in mm.
45.9
18max
¡STATIC CHARACTERISTICS
¡RISE TIME & FALL TIME
24
25
18
16
75
Io=100%
14
Ripple
12
50
10
8
25
160
170
180
190
200
INPUT VOLTAGE
210
220
230
240
20
Io=100%
15
Io=50%
10
5
0
AC Input
ACIN 480V
250
50ms/DIV
V 60Hz (AC 100V)
¡OVERCURRENT CHARACTERISTICS
26
¡INRUSH CURRENT
Input Voltage AC480V
24
22
20A/DIV
150
OUTPUT VOLTAGE V
100
RIPPLE mVp-p
OUTPUT VOLTAGE V
20
OUTPUT VOLTAGE V
DC Output
Output Voltage
22
60Hz
Frequency
100%
Load
Input voltage AC480V
20
18
16
14
12
2
4
6
8
OUTPUT CURRENT A
10
12
50ms/DIV
FCA-2
Download