emc conformance report

advertisement
Manufacturer: Qusteam Group of Companies.
EUT: PESA Switching System (TX and RX)
File Name: Report 001_FCC_PESA_ Rev1.0
FCC Part 15, Subpart B – Class A Unintentional Radiators
Page 1 of 24
EMC CONFORMANCE REPORT
REPORT NUMBER:
001_FCC_PESA_ Rev 1.0
REVISION:
1.0
MANUFACTURER:
QUSTREAM GROUP OF COMPANIES
EQUIPMENT NAME:
PESA SWITCHING SYSTEM
EQUIPMENT MODEL:
DVTX-V5A2F-PS & DVRX-V5A2F-PS
EQUIPMENT SERIAL:
652929A07420091 & 652930A07420127
START DATE:
November 1, 2007
REPORT ISSUE DATE: January 31, 2007
Testing Completed by:
Mahbub Hossain
Report Completed by:
Mahbub Hossain
Report reviewed by:
Victor Kuczynski
VICAN ELECTRONICS
PROVIDING EMC SOLUTIONS SINCE 1987
2721 Markham Road Unit 36, Scarborough Ontario, Canada M1X 1L5
Tel: (416) 412-2111, Fax (416) 412-7760, Email: vican@on.aibn.com, www@vican.ca
Manufacturer: Qusteam Group of Companies.
EUT: PESA Switching System (TX and RX)
File Name: Report 001_FCC_PESA_ Rev1.0
FCC Part 15, Subpart B – Class A Unintentional Radiators
Page 2 of 24
Revision History
Revision
1.0
Date
January 31, 2007
VICAN ELECTRONICS
Description
Issue
PROVIDING EMC SOLUTIONS SINCE 1987
2721 Markham Road Unit 36, Scarborough Ontario, Canada M1X 1L5
Tel: (416) 412-2111, Fax (416) 412-7760, Email: vican@on.aibn.com, www@vican.ca
Manufacturer: Qusteam Group of Companies.
EUT: PESA Switching System (TX and RX)
File Name: Report 001_FCC_PESA_ Rev1.0
FCC Part 15, Subpart B – Class A Unintentional Radiators
Page 3 of 24
1.0
OVERVIEW
1.1
INTRODUCTION..................................................................................................... 4
1.1.1
1.1.2
1.1.3
1.1.4
Scope.....................................................................................................................................4
Related Products ...................................................................................................................4
Purpose .................................................................................................................................4
Summary ...............................................................................................................................5
1.2
SYSTEM TEST CONFIGURATION ........................................................................ 5
1.2.1
1.2.2
1.2.3
1.2.4
1.2.5
1.2.6
1.2.7
Product Description ...............................................................................................................5
Equipment Configuration .......................................................................................................5
Operation Mode.....................................................................................................................5
Special Accessories ..............................................................................................................5
Equipment Modifications .......................................................................................................5
Auxiliary Equipments .............................................................................................................6
Test Location .........................................................................................................................6
2.0
EMISSION
2.1
RADIATED RF EMISSION ..................................................................................... 7
2.1.1
2.1.2
2.1.3
2.1.4
2.1.5
2.1.6
List of Equipment Used .........................................................................................................7
Test Methodology ..................................................................................................................7
Test Configuration .................................................................................................................7
Test Procedure ......................................................................................................................7
Test Results...........................................................................................................................7
Photograph of Test Setup......................................................................................................11
2.2
AC POWER LINE CONDUCTED EMISSION......................................................... 13
2.2.1
2.2.2
2.2.3
2.2.4
2.2.5
2.2.6
List of Equipment Used .........................................................................................................13
Test Methodology ..................................................................................................................13
Test Configuration .................................................................................................................13
Test Procedure ......................................................................................................................13
Test Results...........................................................................................................................13
Photograph of Test Setup......................................................................................................22
ATTACHMENT
ATTACHMENT A: EMC Test Plan .................................................................................. 23
A 1: Product Description ...................................................................... 23
A 2: Block Diagram of Test Setup ....................................................... 23
ATTACHMENT B: Information to the user .................................................................... 24
VICAN ELECTRONICS
PROVIDING EMC SOLUTIONS SINCE 1987
2721 Markham Road Unit 36, Scarborough Ontario, Canada M1X 1L5
Tel: (416) 412-2111, Fax (416) 412-7760, Email: vican@on.aibn.com, www@vican.ca
Manufacturer: Qusteam Group of Companies.
EUT: PESA Switching System (TX and RX)
File Name: Report 001_FCC_PESA_ Rev1.0
FCC Part 15, Subpart B – Class A Unintentional Radiators
Page 4 of 24
1.0 OVERVIEW
1.1
INTRODUCTION
1.1.1
Scope
This report is intended to document performance with essential requirements of the FCC Title 47 CFR,
Part 15 Subpart A & B, Industry Canada ICES-003 Issue 3, EMC Directive 89/336/EEC, EN 55022:1998,
ANSI C63.4 2003, based on the results of testing performed from November 1,2007 to December 1, 2007
on the products PESA Switching System –
DVTX-V52F-PS FIBER DVI/RGBHVAA TRANSMITTER WITH POWER SUPPLY (including coax) &
DVRX-V52F-PS FIBER DVI/RGBHVAA RECEIVER WITH POWER SUPPLY (including coax).
This report only applies to specific samples tested under stated test conditions.
1.1.2
No.
1
2
3
1.1.3
Related Product
Related Products
COAX ONLY RECEIVER AND TRANSMITTER – NO FIBER – WITH POWER SUPPLY
DVRX-V52C-PS COAX DVI/RGBHVAA RECEIVER WITH POWER SUPPLY
DVTX-V52C-PS COAX DVI/RGBHVAA TRANSMITTER WITH POWER SUPPLY
COAX ONLY RECEIVER AND FIBER ONLY RECEIVER – NO POWER SUPPLY
DVRX-V52C COAX DVI/RGBHVAA RECEIVER
DVRX-V52F FIBER DVI/RGBHVAA RECEIVER
COAX ONLY TRANSMITTER AND FIBER ONLY TRANSMITTER – NO POWER SUPPLY
DVTX-V52C COAX DVI/RGBHVAA TRANSMITTER
DVTX-V52F FIBER DVI/RGBHVAA TRANSMITTER
Purpose /Normative Reference
Testing was performed to evaluate the EMC performance on the products PESA Switching System –
DVTX-V52F-PS FIBER DVI/RGBHVAA TRANSMITTER WITH POWER SUPPLY (including coax) &
DVRX-V52F-PS FIBER DVI/RGBHVAA RECEIVER WITH POWER SUPPLY (including coax) -in accordance with the requirements, procedures, and criteria defined in the application of regulations
and application of standards listed below.
Application of Regulations:
FCC Title 47 CFR, Part 15 Subpart A&B, Industry Canada ICES-003
Issue 3, EMC Directive 89/336/EEC, EN 55022 1998, ANSI C63.4 2003
Application of Standards:
Emission:
FCC Title 47 CFR, Part 15 Subpart A&B, Industry Canada ICES-003 Issue 3, EMC
Directive 89/336/EEC, EN 55022 1998, ANSI C63.4 2003
VICAN ELECTRONICS
PROVIDING EMC SOLUTIONS SINCE 1987
2721 Markham Road Unit 36, Scarborough Ontario, Canada M1X 1L5
Tel: (416) 412-2111, Fax (416) 412-7760, Email: vican@on.aibn.com, www@vican.ca
Manufacturer: Qusteam Group of Companies.
EUT: PESA Switching System (TX and RX)
File Name: Report 001_FCC_PESA_ Rev1.0
FCC Part 15, Subpart B – Class A Unintentional Radiators
Page 5 of 24
1.1.4
Summary
TEST TYPE
SPECIFICATION
TEST METHOD
REQUIREMENTS
Radiated RF
Emission
FCC Part 15, Subpart B
EN 55022:1998
ICES-003
ANSI C63.4:2001
EN 55022
AC Power Line
Conducted
Emission
FCC Part 15, Subpart B
EN 55022:1998
ICES-003
ANSI C63.4:2001
EN 55022
30 MHz to 1GHz Class A
30 – 88 MHz 39dBuV/m at 10m
88 – 216MHz 43.5dBuV/m at 10m
216 – 960MHz 46.5dbuV/m at 10m
960 – 1GHz 49.5dbuV/m at 10m
150 kHz to 30 MHz Class A
0.15 – 0.5 MHz 79dBuV QP, 66dBuV AV
0.5 –30 MHz 73dBuV QP, 60dBuV AV
CRITERION
RESULTS
Pass
Pass
All test results in this test report are traceable to National Institute of Standards and Technology (NIST)
and/or National Research Council (NRC).
1.2
SYSTEM TEST CONFIGURATION
1.2.1
Product Description
The information for all equipment used in the tested system has been supplied by manufacturer and is
listed in the EMC Test Plan in Attachment A.
1.2.2
Equipment Configuration
A description and justification of the equipment configuration is given in the EMC Test Plan.
Radiated Emission was performed under the full cable configuration.
The EUT was tested as tabletop equipment and was configured and operated in a manner consistent with
its intended use. The EUT was connected to rate power and allowed to warm up.
1.2.3
Operation Mode
The operating mode was selected to produce worse case radiation and place the EUT in the most
susceptible state. There were no deviations from the description given in the EMC Test Plan.
1.2.4
Special Accessories
None added.
1.2.5
Equipment Modification for radiated emission only.
Audio output cables (if used) require ferrites with impedance of single turn equal or greater then
100ohm@25MHz and 180ohm @100MHz.
Ferrite require on USB cable (if used) with impedance of single turn equal or greater then 170ohm
@25MHz and 320ohm @100MHz.
Please see the picture below.
VICAN ELECTRONICS
PROVIDING EMC SOLUTIONS SINCE 1987
2721 Markham Road Unit 36, Scarborough Ontario, Canada M1X 1L5
Tel: (416) 412-2111, Fax (416) 412-7760, Email: vican@on.aibn.com, www@vican.ca
Manufacturer: Qusteam Group of Companies.
EUT: PESA Switching System (TX and RX)
File Name: Report 001_FCC_PESA_ Rev1.0
FCC Part 15, Subpart B – Class A Unintentional Radiators
Page 6 of 24
Ferrite on
Audio Out
Ferrite on
Audio Out
Ferrite on
USB
Ferrite on
USB
Picture with ferrites on USB & audio out ports of both Transmitter and Receiver
1.3.6
No
1
Auxiliary Equipment
2
Description
SAMSUNG Sync Master
Monitor
Personal Computer (Desktop)
3
Model Number
750S-DT17LS7L
Serial Number
DT17HCCN5041614
Cable Type
N/A
N/A
N/A
N/A
Keyboard
107/108
N/A
N/A
4
Mouse
N/A
N/A
N/A
5
ITE Power Supply
GT-21148-3012-T3
RoHS01070604/07
6
ITE Power Supply
GT-21148-3012-T3
RoHS01071604/07
7
Speaker(s)
N/A
N/A
1.2.7
Non-shielded
non twisted
pair
Non-shielded
non twisted
pair
N/A
Test Location
Radiated RF Emission was performed at InterTek’s 10 meter Open Area Test Site (OATS) located in the
town of Kitchener, Province of Ontario.
AC Power Line Conducted Emission was performed in Vican Electronics’ shielded room, 8’ (L) by 8’ (W)
by 8’ (H).
The above sites have been calibrated in accordance with ANSI C63.4, and found to be in compliance with
the requirements of Sec. 2.948 of the FCC Rules. The descriptions and site measurement data of
Kitchener OATS has been filed with FCC office (FCC File No.: 90578). Last date of site calibration:
August 17, 2006 and due date: August 16, 2009.
VICAN ELECTRONICS
PROVIDING EMC SOLUTIONS SINCE 1987
2721 Markham Road Unit 36, Scarborough Ontario, Canada M1X 1L5
Tel: (416) 412-2111, Fax (416) 412-7760, Email: vican@on.aibn.com, www@vican.ca
Manufacturer: Qusteam Group of Companies.
EUT: PESA Switching System (TX and RX)
File Name: Report 001_FCC_PESA_ Rev1.0
FCC Part 15, Subpart B – Class A Unintentional Radiators
Page 7 of 24
2.0 EMISSION
2.1
RADIATED RF EMISSION
2.1.1
List of Equipment Used
No.
1
2
3
4
Description
Spectrum Analyzer
CHASE BILOG ANTENNA
RF-amplifier (0.1MHz-1300MHz)
+26dB
RF-Pre-selector
Model
Advantest R3131
UPA6192
Serial Number
J004024
NA6006
Cal. Due Date
Sept. 15, 2008
Dec. 14, 2008
HP 8447D
1937A03172
May. 9, 2008
Tektronix 2706
B010638
Aug. 28, 2008
Above equipment is periodically calibrated with tractability to NIST and /or NRC
2.1.2
Test Methodology
Test was performed according to the methods listed in the report at paragraph 1.1.2. This test evaluates
potential of EUT for causing radio frequency interference to other electronic devices. There were no
deviations from the test standard.
2.1.3
Test Configuration
The testing was performed on the 10-METER OPEN AREA TEST SITE. The EUT was placed on a nonconductive remotely controlled rotated table 80cm above the ground plane. Testing was performed at an
antenna to EUT distance of 10 meters.
Radiated RF Emission was performed at InterTek’s 10 meter Open Area Test Site (OATS) located in the
town of Kitchener, Province of Ontario.
The above site have been calibrated in accordance with ANSI C63.4, and found to be in compliance with
the requirements of Sec. 2.948 of the FCC. The description and site measurement data of Kitchener
OATS has been field with FCC office (FCC file No.: 90578).
A photograph of the test configuration is shown in the attached data
2.1.4
Test Procedure
The EUT was tested on the 10-METER OPEN AREA TEST SITE. For each frequency measured, the
peak emission was maximized by raising or lowering the receiving antenna on the antenna tower within 1
to 4 meters from the ground plane and placing it at the position, which produced maximum signal strength
reading. The I/O cables were also manipulated to the position, which produced high emission. The
turntable was rotated through 360° while observing the peak signal and placing the EUT at the position
that produced maximum radiation. The procedure was performed in both horizontal and vertical antenna
polarization. The peak emission data was recorded into Measurement Table. When the peak emissions
were more then 20dB below the limit they were not recorded.
2.1.5
Test Results
The test data is listed in the Radiated Frequency Emission Data Record.
The EUT was found to be compliant with modifications to the requirements of the test standard to FCC
Part 15, Subpart B Class A.
VICAN ELECTRONICS
PROVIDING EMC SOLUTIONS SINCE 1987
2721 Markham Road Unit 36, Scarborough Ontario, Canada M1X 1L5
Tel: (416) 412-2111, Fax (416) 412-7760, Email: vican@on.aibn.com, www@vican.ca
Manufacturer: Qusteam Group of Companies.
EUT: PESA Switching System (TX and RX)
File Name: Report 001_FCC_PESA_ Rev1.0
FCC Part 15, Subpart B – Class A Unintentional Radiators
Page 8 of 24
RADIATED FREQUENCY EMISSION DATA RECORD
Method: ANSI C63.4: 2001
EN 55022
Standard: FCC Part 15, Subpart B
EN 55022:1998
ICES-003
Manufacturer: Qustream Group Companies
Start Date: Nov. 30 & Dec.1, 2007
EUT Name: PESA Switching System (TX & RX)
Witness: N/A
EUT Model: DVRX-U5A2F&DVTX-U5A2F
Temp: 23 °C
EUT Serial: 652930A07420127/652929A07420091
Humidity: 33 %
Detector Peak RBW: 100KHz VBW: 1MHz
Atmos. Pressure: 1065 mb/hpa
Detector Quasi-Peak RBW: 120KHz VBW: 1MHz
Line AC/Freq.: 120 VAC / 60 Hz
Detector Average RBW: 1MHz VBW: 10Hz
For emissions more than 20dB below limits may not be recorded
Freq.
(MHz)
Azimut
h
(deg)
Ant.
Polarity
(H/V)
Antenna
Height
Raw
Amp.
(dBu/V)
Detector
[P]/[QP]
Antenna
Corr.
(dB/M)
Cable
Loss
(dB)
Adjusted
Amp.
(dBuV/m)
Class A
Limits
(dBuV/m)
Over/
Under
(dBuV/m)
153.1
153.1
188.97
188.97
194.97
194.97
222.68
248.2
248.2
222.7
248.43
251.9
259.98
260.403
259.98
260.423
272.12
272.12
283.99
283.99
20
350
270
0
85
250
180
90
0
30
0
0
10
30
0
180
10
330
10
350
V
H
H
V
H
V
V
V
H
H
H
H
V
V
H
H
H
V
V
H
1.86
1.1
2.6
1.1
1.5
1.1
2.1
1.2
2
2.6
1.1
2.6
1.3
2.8
2.9
2.9
2.9
3
1.8
1.3
39
38
38
39
46
43
40.27
37.2
38
42
41.6
36.5
39
38
42
36.07
42.5
38
45.58
43.5
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
QP
11.9
11.9
10
10
10.2
10.2
11.7
12.4
12.4
11.7
12.4
12.7
12.7
13
12.7
13
13.3
13.3
13.6
13.6
-2.5
-2.5
-2.7
-2.7
-2.7
-2.7
-3
-3.2
-3.2
-3
-3.2
-3.2
-3.2
-3.2
-3.2
-3.2
-3.3
-3.3
-3.3
-3.3
27.4
26.4
24.7
25.7
32.9
29.9
28.97
26.8
27.6
30.7
31.2
26.4
28.9
28.2
31.9
26.27
33.1
28.6
36.48
34.4
43.5
43.5
43.5
43.5
43.5
43.5
46.5
46.5
46.5
46.5
46.5
46.5
46.5
46.5
46.5
46.5
46.5
46.5
46.5
46.5
-16.1
-17.1
-18.8
-17.8
-10.6
-13.6
-17.53
-19.7
-18.9
-15.8
-15.3
-20.1
-17.6
-18.3
-14.6
-20.23
-13.4
-17.9
-10.02
-12.1
Continue……
VICAN ELECTRONICS
PROVIDING EMC SOLUTIONS SINCE 1987
2721 Markham Road Unit 36, Scarborough Ontario, Canada M1X 1L5
Tel: (416) 412-2111, Fax (416) 412-7760, Email: vican@on.aibn.com, www@vican.ca
Manufacturer: Qusteam Group of Companies.
EUT: PESA Switching System (TX and RX)
File Name: Report 001_FCC_PESA_ Rev1.0
FCC Part 15, Subpart B – Class A Unintentional Radiators
Page 9 of 24
Freq.
(MHz)
Azimut
h
(deg)
Ant.
Polarity
(H/V)
Antenna
Height
285.8
285.8
296.99
296.99
299.99
299.99
300.71
300.71
319.5
319.5
355.004
371.234
371.234
325.518
325.518
425.996
425.976
445.51
445.51
458.9
458.9
519.64
519.64
765.059
765.059
0
0
0
0
10
270
180
0
270
270
270
0
180
180
120
0
270
170
0
180
180
330
170
200
200
H
V
H
V
V
H
V
H
H
V
H
H
V
V
H
V
H
H
V
V
H
H
V
H
V
3
1.5
1.1
3
1.1
3
1.2
1.1
2
1.1
1.8
1.4
1.6
2.6
1.5
1.5
1.8
1.4
1.6
2.6
1.5
1.5
1.8
1.4
1.6
Raw
Amp.
(dBu/V)
Detector
[P]/[QP]
Antenna
Corr.
(dB/M)
Cable
Loss
(dB)
42
P
13.6
-3.3
41
P
13.6
-3.3
43.5
P
13.9
-3.3
41
P
13.9
-3.3
44
P
13.9
-3.3
49
P
13.9
-3.3
41.5
P
14
-3.4
42.27
P
14
-3.4
41.96
P
14.2
-3.5
34.24
P
14.2
-3.5
37.02
P
14.8
-3.8
43.66
P
15.2
-3.9
38
P
15.2
-3.9
45.1
P
14.4
-3.6
44.5
P
14.4
-3.6
38.02
P
16.3
-4.2
38.54
P
16.3
-4.2
35.29
P
16.7
-4.3
35
P
16.7
-4.3
36.46
P
16.9
-4.4
35.7
QP
16.9
-4.4
36.86
P
19
-4.7
34.19
P
19
-4.7
37.603
QP
21.8
-6
33.4
QP
21.8
-6
Antenna at 10m distance from EUT
VICAN ELECTRONICS
Adjusted
Amp.
(dBuV/m)
ClassB
Limits
(dBuV/m)
Over/
Under
(dBuV/m)
32.9
31.9
34.7
32.2
35.2
40.2
32.9
33.67
33.66
25.94
29.62
36.76
31.1
37.1
36.5
32.52
33.04
30.29
30
31.76
31
34.56
31.89
39.403
35.2
46.5
46.5
46.5
46.5
46.5
46.5
46.5
46.5
46.5
46.5
46.5
46.5
46.5
46.5
46.5
46.5
46.5
46.5
46.5
46.5
46.5
46.5
46.5
46.5
46.5
-13.6
-14.6
-11.8
-14.3
-11.3
-6.3
-13.6
-12.83
-12.84
-20.56
-16.88
-9.74
-15.4
-9.4
-10
-13.98
-13.46
-16.21
-16.5
-14.74
-15.5
-11.94
-14.61
-7.097
-11.3
PROVIDING EMC SOLUTIONS SINCE 1987
2721 Markham Road Unit 36, Scarborough Ontario, Canada M1X 1L5
Tel: (416) 412-2111, Fax (416) 412-7760, Email: vican@on.aibn.com, www@vican.ca
Manufacturer: Qusteam Group of Companies.
EUT: PESA Switching System (TX and RX)
File Name: Report 001_FCC_PESA_ Rev1.0
FCC Part 15, Subpart B – Class A Unintentional Radiators
Page 10 of 24
Radiated Emission Measurement at 10m OAT Site
Amplitude[dBuv/m]
60
50
40
30
20
10
0
10
100
Frequency[MHz]
Measured Data
VICAN ELECTRONICS
FCC Class A Limits
PROVIDING EMC SOLUTIONS SINCE 1987
2721 Markham Road Unit 36, Scarborough Ontario, Canada M1X 1L5
Tel: (416) 412-2111, Fax (416) 412-7760, Email: vican@on.aibn.com, www@vican.ca
1000
Manufacturer: Qusteam Group of Companies.
EUT: PESA Switching System (TX and RX)
File Name: Report 001_FCC_PESA_ Rev1.0
FCC Part 15, Subpart B – Class A Unintentional Radiators
Page 11 of 24
2.1.6
Photograph of Test Setup of Radiated RF Emission at OATS
Front view during the test on Nov 30,07 at OATS
Beck view during the test on Dec.1, 07 at OATS.
VICAN ELECTRONICS
PROVIDING EMC SOLUTIONS SINCE 1987
2721 Markham Road Unit 36, Scarborough Ontario, Canada M1X 1L5
Tel: (416) 412-2111, Fax (416) 412-7760, Email: vican@on.aibn.com, www@vican.ca
Manufacturer: Qusteam Group of Companies.
EUT: PESA Switching System (TX and RX)
File Name: Report 001_FCC_PESA_ Rev1.0
FCC Part 15, Subpart B – Class A Unintentional Radiators
Page 12 of 24
Front view during the test on Dec.1, 07 at OATS
VICAN ELECTRONICS
PROVIDING EMC SOLUTIONS SINCE 1987
2721 Markham Road Unit 36, Scarborough Ontario, Canada M1X 1L5
Tel: (416) 412-2111, Fax (416) 412-7760, Email: vican@on.aibn.com, www@vican.ca
Manufacturer: Qusteam Group of Companies.
EUT: PESA Switching System (TX and RX)
File Name: Report 001_FCC_PESA_ Rev1.0
FCC Part 15, Subpart B – Class A Unintentional Radiators
Page 13 of 24
2.2 AC POWER LINE CONDUCTED EMISSION
2.2.1
No.
List of Equipment Used
2
Description
CISPR EMI Receiver ( HP
8568B, HP 85685A,
HP85650A )
EMCO LISN
3
Coaxial Cable
4
Personal Computer
1
Model
Serial Number
HP 8574A
2043A00309 2344A05956
2338A03044 2724A00541
3816/2NM
BELDEN
9310
PC AT
Cal. Due Date
Nov.12, 2008
9701105R
003
N/A
Oct. 10, 2008
Oct. 9, 2008
Verification
Above equipment is periodically calibrated with traceability to NIST and /or NRC
2.2.2
Test Methodology
Test was performed according to the methods listed in the report at point 1.1.2. This test evaluates
potential of EUT for causing power line interference to other electronic devices. There were no deviations
from the test standard.
2.2.3
Test Configuration
The EUT was placed on non-conductive table 80cm above the ground plane. The LISN was placed on
the ground plane and connected to the receiver.
A photograph of the test configuration is shown in attached data.
2.2.4
Test Procedure
The frequency range of interest was 150KHz to 30 MHz. Conducted emissions from each AC power line
was measured with respect to ground.
EUT was tested with line voltage 120VAC/60Hz.
2.2.5
Test Results
Plots of the EUT’s AC Power Line Conducted Emissions were contained in the following pages. The plots
showed peak emission. If the peak emissions or QP emission were below the quasi-peak and average
limit, then the EUT was considered to pass without testing in QP and AV detector modes.
The EUT was found to be compliant to the requirements of the test standard as originally tested to
Class A of the FCC Part 15B.
VICAN ELECTRONICS
PROVIDING EMC SOLUTIONS SINCE 1987
2721 Markham Road Unit 36, Scarborough Ontario, Canada M1X 1L5
Tel: (416) 412-2111, Fax (416) 412-7760, Email: vican@on.aibn.com, www@vican.ca
Manufacturer: Qusteam Group of Companies.
EUT: PESA Switching System (TX and RX)
File Name: Report 001_FCC_PESA_ Rev1.0
FCC Part 15, Subpart B – Class A Unintentional Radiators
Page 14 of 24
Result of the Conducted Emission Tests
Plot of receiver line 1 at 120VAC/60Hz operating mode
VICAN ELECTRONICS
PROVIDING EMC SOLUTIONS SINCE 1987
2721 Markham Road Unit 36, Scarborough Ontario, Canada M1X 1L5
Tel: (416) 412-2111, Fax (416) 412-7760, Email: vican@on.aibn.com, www@vican.ca
Manufacturer: Qusteam Group of Companies.
EUT: PESA Switching System (TX and RX)
File Name: Report 001_FCC_PESA_ Rev1.0
FCC Part 15, Subpart B – Class A Unintentional Radiators
Page 15 of 24
Plot of receiver line 2 at 120VAC/60Hz operating mode
VICAN ELECTRONICS
PROVIDING EMC SOLUTIONS SINCE 1987
2721 Markham Road Unit 36, Scarborough Ontario, Canada M1X 1L5
Tel: (416) 412-2111, Fax (416) 412-7760, Email: vican@on.aibn.com, www@vican.ca
Manufacturer: Qusteam Group of Companies.
EUT: PESA Switching System (TX and RX)
File Name: Report 001_FCC_PESA_ Rev1.0
FCC Part 15, Subpart B – Class A Unintentional Radiators
Page 16 of 24
Plot of transmitter line 1 at 120vac/60Hz operating mode
VICAN ELECTRONICS
PROVIDING EMC SOLUTIONS SINCE 1987
2721 Markham Road Unit 36, Scarborough Ontario, Canada M1X 1L5
Tel: (416) 412-2111, Fax (416) 412-7760, Email: vican@on.aibn.com, www@vican.ca
Manufacturer: Qusteam Group of Companies.
EUT: PESA Switching System (TX and RX)
File Name: Report 001_FCC_PESA_ Rev1.0
FCC Part 15, Subpart B – Class A Unintentional Radiators
Page 17 of 24
Plot of transmitter line 2 at 120VAC/60Hz operating mode
VICAN ELECTRONICS
PROVIDING EMC SOLUTIONS SINCE 1987
2721 Markham Road Unit 36, Scarborough Ontario, Canada M1X 1L5
Tel: (416) 412-2111, Fax (416) 412-7760, Email: vican@on.aibn.com, www@vican.ca
Manufacturer: Qusteam Group of Companies.
EUT: PESA Switching System (TX and RX)
File Name: Report 001_FCC_PESA_ Rev1.0
FCC Part 15, Subpart B – Class A Unintentional Radiators
Page 18 of 24
Plot of transmitter line 1 at 230VAC/50Hz operating mode
VICAN ELECTRONICS
PROVIDING EMC SOLUTIONS SINCE 1987
2721 Markham Road Unit 36, Scarborough Ontario, Canada M1X 1L5
Tel: (416) 412-2111, Fax (416) 412-7760, Email: vican@on.aibn.com, www@vican.ca
Manufacturer: Qusteam Group of Companies.
EUT: PESA Switching System (TX and RX)
File Name: Report 001_FCC_PESA_ Rev1.0
FCC Part 15, Subpart B – Class A Unintentional Radiators
Page 19 of 24
Plot of transmitter line 2 at 230VAC/50Hz operating mode
VICAN ELECTRONICS
PROVIDING EMC SOLUTIONS SINCE 1987
2721 Markham Road Unit 36, Scarborough Ontario, Canada M1X 1L5
Tel: (416) 412-2111, Fax (416) 412-7760, Email: vican@on.aibn.com, www@vican.ca
Manufacturer: Qusteam Group of Companies.
EUT: PESA Switching System (TX and RX)
File Name: Report 001_FCC_PESA_ Rev1.0
FCC Part 15, Subpart B – Class A Unintentional Radiators
Page 20 of 24
Plot of receiver line 1 at 230VAC/50Hz operating mode
VICAN ELECTRONICS
PROVIDING EMC SOLUTIONS SINCE 1987
2721 Markham Road Unit 36, Scarborough Ontario, Canada M1X 1L5
Tel: (416) 412-2111, Fax (416) 412-7760, Email: vican@on.aibn.com, www@vican.ca
Manufacturer: Qusteam Group of Companies.
EUT: PESA Switching System (TX and RX)
File Name: Report 001_FCC_PESA_ Rev1.0
FCC Part 15, Subpart B – Class A Unintentional Radiators
Page 21 of 24
Plot of receiver line 2 at 230VAC/50Hz operating mode
VICAN ELECTRONICS
PROVIDING EMC SOLUTIONS SINCE 1987
2721 Markham Road Unit 36, Scarborough Ontario, Canada M1X 1L5
Tel: (416) 412-2111, Fax (416) 412-7760, Email: vican@on.aibn.com, www@vican.ca
Manufacturer: Qusteam Group of Companies.
EUT: PESA Switching System (TX and RX)
File Name: Report 001_FCC_PESA_ Rev1.0
FCC Part 15, Subpart B – Class A Unintentional Radiators
Page 22 of 24
2.2.6
Photograph of Test Setup of AC Power Line Conducted Emission.
Receiver
Transmitter
VICAN ELECTRONICS
PROVIDING EMC SOLUTIONS SINCE 1987
2721 Markham Road Unit 36, Scarborough Ontario, Canada M1X 1L5
Tel: (416) 412-2111, Fax (416) 412-7760, Email: vican@on.aibn.com, www@vican.ca
Manufacturer: Qusteam Group of Companies.
EUT: PESA Switching System (TX and RX)
File Name: Report 001_FCC_PESA_ Rev1.0
FCC Part 15, Subpart B – Class A Unintentional Radiators
Page 23 of 24
ATTACHMENT
ATTACHMENT A: EMC TEST PLAN
A. 1
Product Description
These Products are a transmitter and a receiver of PESA switching system supplied by the manufacture.
Normally 120VAC/60Hz was supplied to run the EUT. It is connected with a SAMSUNG SynsMaster 750s
monitor, a keyboard and a mouse. Two speakers are connected with both EUTs communication ports.
For the normal operations of EUTs are necessary to connect power and connection between transmitter
and receiver, monitor and speakers but keyboards and mouse are not required for normal operation.
Testing related to the power supply does not require to be done.
A. 2
Block Diagram of Test Setup
ATX
Frame
Computer
EUTs
Keyboard
Transmitter
Mouse
Coaxial
Receiver
Cable
TABLE
120VAC/60Hz
POWER
VICAN ELECTRONICS
PROVIDING EMC SOLUTIONS SINCE 1987
2721 Markham Road Unit 36, Scarborough Ontario, Canada M1X 1L5
Tel: (416) 412-2111, Fax (416) 412-7760, Email: vican@on.aibn.com, www@vican.ca
Monitor
Manufacturer: Qusteam Group of Companies.
EUT: PESA Switching System (TX and RX)
File Name: Report 001_FCC_PESA_ Rev1.0
FCC Part 15, Subpart B – Class A Unintentional Radiators
Page 24 of 24
ATTACHMENT B:
INFORMATION TO THE USER ACCORDING TO REQUIRMENT OF FCC 47 CFR
PARAGRAPH §15.105
For a Class A digital device or peripheral, the instructions furnished the user shall
include the following or similar statement, placed in a prominent location in the text of
the manual:
NOTE: This equipment has been tasted and found to comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC Rules. These limits are design to provide reasonable protection against
harmful interference when the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with
the instruction manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case the user will be
required to correct the interference at this own expense.
VICAN ELECTRONICS
PROVIDING EMC SOLUTIONS SINCE 1987
2721 Markham Road Unit 36, Scarborough Ontario, Canada M1X 1L5
Tel: (416) 412-2111, Fax (416) 412-7760, Email: vican@on.aibn.com, www@vican.ca