PE100-1 Product Specifications PE100-1 Power Extender APPLICATION PE100-1 Power Extender Leviton’s PE100-1 Power Extender allows a dimming zone’s power handling capacity to be extended to a full 1920W/VA on 120V input power. It allows a zone to dim or switch a fully loaded circuit of incandescent and magnetic low voltage loads only. FEATURES & BENEFITS • Works with incandescent, magnetic low voltage, halogen or neon/cold cathode lighting • Low-end trim available for setting the minimum brightness level • Emulates the characteristics of the dimmer that it is connected to in terms of dimming range and resolution • Works with any Dimensions Multi-zone Controller/Dimmer to extend load capacity on any zone 4.50 (114.3 mm) 2.80 (71.1 mm) 4.72 (119.9 mm) 2.06 (52.3 mm) MOUNTING All Power Extenders must have 4-1/2" spacing above and below each unit for proper ventilation and heat dissipation (refer to figure 3). Line voltage wiring should be at least 6ft away from sound or electronic equipment wiring. Mount Power Extender to wall box with “TOP” facing up as follows: For Wall Box Mounting (refer to figure 1), for Flush Mounting (refer to figure 2) and for Panel Mounting (not shown), proceed as follows: a. The enclosure must be in accordance with all local and national electrical codes. b. Leviton DOES NOT recommend using a door to enclose the front of a panel, since this restricts airflow to the controls. c. If mounting multiple controls in an enclosure: • Ambient timperature within an enclosure “MUST REMAIN BETWEEN”32 o-104o F (0 o-40 oC). • If not mounting in a metal enclosure, all units “MUST” be mounted in a wall box. d. To improve heat dissipation of controls, remove the faceplate from the unit. Figure 3: Front View Spacing 1900 Box TOP 2 Gang Raised Cover Raised Cover Mounting Screws (4 Places) TOP 4-1/2" (11.4 cm) Minimum Power Extender Power Extender Wallplate Figure 1: Surface Mounting TOP 1900 Box 2 Gang Raised Cover Raised Cover Mounting Screws (4 Places) 4-1/2" (11.4 cm) Minimum TOP Power Extender Figure 2: Flush Mounting Power Extender Wallplate SPECIFICATION SUBMITTAL JOB NAME: CATALOG NUMBERS: JOB NUMBER: Leviton Mfg. Co., Inc. 59-25 Little Neck Pkwy • Little Neck, NY 11362-2591 • Tech Line: 1-800-824-3005 • Fax: 1-800-832-9538 Visit our Website at: www.leviton.com 1 Product Specifications PE100-1 ......................... SPECIFICATIONS Wiring Diagram 1A: Single Feed Wiring Application w/Controller Warranty: Limited 2-Year Warranty (Load) Single Feed Wiring Line Hot can be controlled by one circuit breaker as long as the total load does not exceed the Power rating of the Extender circuit breakers. D3206/08 Controller/Dimmer HOT Neutral Line SWITCH HOT LOAD NEUTRAL NEUTRAL • For Box-Mounted Dimmers: Must use a 120V, 600W Incandescent version from the following families: IllumaTech™, Mural™, True Touch™, ToggleTouch™, TouchPoint™ and Home Controls • For Monet™ installations, use a 120V, 600VA Monet Magnetic Low Voltage dimmer (requires a Neutral wire) • For dimmers that include a Neutral wire (such as some scene-capable dimmers), the dimmer Neutral wire must be connected • For Architectural Systems: Works with all families Hot (Black) (120VAC) Environmental Operating Temperature Range: 0ºC to 40ºC Storage Temperature Range: -10ºC to 85ºC Relative Humidity: 20%-90% non-condensing CONTROL Compatibility Load Green Ground LOAD Neutral (White) Wiring Diagram 1B: Single Feed Wiring Application w/Dimmer Used if Dimmer/Switch has Neutral connection Hot (Black) (120VAC) (Load) Single Feed Wiring Line Hot can be controlled by one circuit breaker as long as the total load does not exceed the rating of the Power Extender circuit breakers. Physical Color: Aluminum clear anodized extruded heat sink with a snap-on molded white cover Size: 4.72"L x 4.5"W x 0.5"H (120mm x 114mm x 12.7mm) HOT LOAD NEUTRAL SWITCH HOT Dimmer CONTROL Input Voltage: 120V, 50/60Hz Load Rating: 1920W/VA Load Output Power: Phase independent of control device Dimmer Input: 120V 50/60Hz Testing/Code Compliance: UL Listed, CSA Certified and FCC Part 15 NEUTRAL Electrical White Black Load Green Ground LOAD Neutral (White) Wiring Diagram 2A: Dual Feed Wiring Application w/Controller Wiring Diagram 2B: Dual Feed Wiring Application w/Dimmer Used if Dimmer/Switch has Neutral connection Hot (Black) Line 1 (120VAC) (Load) Green Ground LOAD Hot (Black) Line 2 (120VAC) Neutral 2 (White) Neutral 2 (White) Wiring Diagram 3: Dual Feed Wiring Application w/Dimmer and Two Power Extenders Hot (Black) Line (120VAC) (Load) (Load) D3206/08 Controller/Dimmer HOT SWITCH HOT NEUTRAL LOAD NEUTRAL Power Extender CONTROL SWITCH HOT HOT LOAD NEUTRAL NEUTRAL CONTROL Neutral (White) Dual Feed Wiring The Input control circuit and the Output load circuit can be supplied by two circuit Power breakers on Extender a single phase or by two separate Hot (Black) Line 1 (120VAC) phases. Neutral Line Load Note: Up to 4 Power Extenders can be Connected together. Green Ground LOAD 1 Neutral (White) Hot (Black) Line 2 (120VAC) LOAD 2 Neutral (White) Leviton Mfg. Co., Inc. 59-25 Little Neck Pkwy • Little Neck, NY 11362-2591 • Tech Line: 1-800-824-3005 • Fax: 1-800-832-9538 Visit our Website at: www.leviton.com © Copyright 2003 Leviton Manufacturing Co., Inc. All rights reseved. G-6723/G3 SWITCH HOT HOT LOAD Dimmer NEUTRAL Dual Feed Wiring The Input control circuit and the Output load circuit can be supplied by two circuit breakers Power on a single phase Extender or by two separate phases. Load Hot (Black) Line 2 (120VAC) (Load) Neutral 1 (White) Neutral Line SWITCH HOT LOAD HOT CONTROL NEUTRAL Dual Feed Wiring The Input control circuit and the Output load circuit can be supplied by two circuit breakers on a single phase Power Extender or by two separate phases. NEUTRAL D3206/08 Controller/Dimmer CONTROL Neutral 1 (White) NEUTRAL Hot (Black) Line 1 (120VAC) White Black Load Green Ground LOAD