Catalog Number Notes FEATURES The Remote Dimmer Module (RDMI) provides remote control dimming and switching for a variety of lamp sources in response to the phase control output of another dimming device. The RDMI is powered independently from the controlling device, making it ideal for expanding dimming capacity or mixing lamp voltages on a single system. • Dimmer controls incandescent, magnetic low voltage, halogen and neon/cold cathode lighting • 1920 watt capacity at 120 volts • Mounts to standard 4" J-box • Electronic soft start of lamps • LED indicators for line and control power • Convection cooled • Square law dimming • Type Remote Incandescent Dimmer Module RDMI 2000 120 Integral air gap relay SPECIFICATIONS FUNCTIONAL • Provides dimming of up to one full circuit of lighting in response to a control signal from the output of a compatible dimmer channel. • Dimmer: Universal type, suitable for incandescent, magnetic low voltage, neon, cold cathode and tungsten halogen sources. • Control Input: Dimmed output (phase control) from a SQIDC or ISD I dimmer. • Output: Linear with respect to control input within 10%. ELECTRICAL • Dimmer Capacity: 1920VA at 120V incandescent, tungsten halogen; 1920VA at 120V neon, cold cathode and magnetic low voltage dimming ballasts; • Input Power: May be a separate branch circuit or shared with the controlling dimmer circuit. • Phasing: No phase relationship required between RDM and the controlling dimmer. • Relay: Air gap for positive on/off operation. • Indicators: Separate LED for input power and control power. • Termination: Terminal Blocks MECHANICAL • Enclosure: NEMA 1; CRS with extruded aluminum heat sink; rated for use in return air plenum. • Mounting: Any orientation; replace cover on standard 4" J-box. ORDERING INFORMATION RDMI RDMI Series RDMI Controls Example: RDMI 2000 120 2000 120 2000 120 Capacity/voltage 2000 120 1920 VA at 120V Sheet #: RDMI 2000 120 RDMI Remote Incandescent Dimming Module DIMENSIONS All dimensions are in inches (millimeters). WIRING DIAGRAMS 4.50 (114.3 mm) 2.06 (52.3 mm) Single Feed with Dimmer Hot (Black) Line 1 (120VAC) (Load) HOT 2.80 (71.1 mm) Neutral Line SWITCH HOT LOAD CONTROL NEUTRAL NEUTRAL Dimmer Dual Feed Wiring The Input control circuit and the Output load circuit can be supplied by two circuit breakers on a single phase Power Extender or by two separate phases. 4.72 (119.9 mm) Neutral 1 (White) Load Green Ground Hot (Black) Line 2 (120VAC) LOAD Neutral 2 (White) Dual Feed with Dimmer Hot (Black) (120VAC) (Load) Single Feed Wiring Line Hot can be controlled by one circuit breaker as long as the total load does not exceed the Power rating of the Extender circuit breakers. HOT Neutral Line SWITCH HOT LOAD NEUTRAL CONTROL NEUTRAL Dimmer Load Green Ground LOAD Neutral (White) Dual Feed with Dimmer and 2 RDMs Hot (Black) Line (120VAC) Note: Up to 4 Power Extenders can be Connected together. (Load) (Load) Neutral (White) Power Extender HOT SWITCH HOT LOAD CONTROL NEUTRAL NEUTRAL SWITCH HOT HOT LOAD CONTROL NEUTRAL Dimmer NEUTRAL Dual Feed Wiring The Input control circuit and the Output load circuit can be supplied by two circuit Power breakers on Extender a single phase or by two separate Hot (Black) Line 1 (120VAC) phases. Neutral Line Load Green Ground LOAD 1 Neutral (White) Hot (Black) Line 2 (120VAC) LOAD 2 Neutral (White) Synergy Lighting Controls Sheet #: RDMI ©1991 Acuity Lighting Group, Inc., Rev. 7/13 One Lithonia Way, Conyers, GA 30012 Phone: 800-533-2719 www.synergylightingcontrols.com