HQ KK Wind Solutions A/S Bøgildvej 3 DK-7430 Ikast Phone Fax CVR +45 96 92 43 00 +45 97 21 14 31 25 74 67 16 E-mail Web main@kkwindsolutions.com www.kkwindsolutions.com Datasheet WTC6 CM60 Controller module typically used as main controller in wind turbine control systems. The controller works together with the other WTC6 modules and also WTC3 modules. Datasheet revised: 2015-07-22. Version no. 1.7 Contents 1 Introduction ........................................................................................................................ 3 1.1 Part numbers .................................................................................................................. 3 2 Important note ................................................................................................................... 3 3 Features .............................................................................................................................. 4 5 Environmental data ............................................................................................................. 5 5.1 Temperature .................................................................................................................. 5 5.2 Humidity ......................................................................................................................... 5 5.3 Ventilation ...................................................................................................................... 5 6 On-board sensors ................................................................................................................ 6 6.1 Temperature sensor ....................................................................................................... 6 6.2 Real time clock ............................................................................................................... 6 7 Interfaces ............................................................................................................................ 7 7.1 X1 - Ethernet .................................................................................................................. 7 7.2 X2 - Console port (RS232) ............................................................................................... 7 7.3 X3 - USB .......................................................................................................................... 8 7.4 X4 & X5 - System bus and supply .................................................................................... 8 7.5 X6 - System bus .............................................................................................................. 8 8 Communication topology .................................................................................................... 9 8.1 Top station mode ........................................................................................................... 9 8.2 Substation mode ............................................................................................................ 9 8.3 Subnet .......................................................................................................................... 10 9 LED Indicators ................................................................................................................... 11 10 Standards.......................................................................................................................... 12 10.1 EMC standards.............................................................................................................. 12 10.2 Vibration....................................................................................................................... 12 10.3 PLC standards ............................................................................................................... 12 11 Mechanical ....................................................................................................................... 13 11.1 Mounting ...................................................................................................................... 13 11.2 Dimension and weight .................................................................................................. 13 12 Accessories ....................................................................................................................... 14 Copyright © KK Wind Solutions A/S, Denmark Page 2 of 14 1 Introduction The CM60 is a core member of the sixth generation control system known as WTC6, developed by KK Wind Solutions. It is a controller module which is typically used as main controller in a wind turbine control system. It contains a powerful processor with fast working RAM, Flash, NVRAM, Ethernet port, EtherCAT master (LVDS), EtherCAT slave (LVDS), USB 2.0 host, internal Real Time Clock, temperature monitoring and ready status output. The CM60 can either be top level controller module, controlling and servicing the communication and instrumentation network, or it can be set as slave in an existing network, where local processor power or higher network update frequencies are needed. Working memory is, for stability and safety purposes, subject to continual ECC control. ECC enables automatic correction of any single bit error and detection of multiple bit errors. 1.1 Part numbers This datasheet covers the following part numbers. CM60 ............................................ : Standard edition. 2 Important note ESD (Electro Static Discharge) sensitive devices on Printed Circuit Board. Take the necessary precautions when working on ESD sensitive parts. Copyright © KK Wind Solutions A/S, Denmark Page 3 of 14 3 Features • • • • • • • • • • • • • • • • Freescale Power Quicc II Pro 800 MHz processor Ethernet 100 Mbit/s (RJ45) interface EtherCAT Master LVDS bus connection to sub modules EtherCAT Slave LVDS bus connection from other EtherCAT net USB 2.0 host, for external storage attachment 512 Mbyte fast working RAM with ECC supervision (Error-correcting code) 128 Mbyte program Flash 512 Kbyte NVRAM 8 Mbyte serial flash for data / log Single 5 VDC external supply from PS60 Internal DC / DC converters with supervision Internal temperature measurement Real Time Clock with capacitive power backup Output enable control and monitoring Station ready control and monitoring Temperature range -35 °C to 70 °C Copyright © KK Wind Solutions A/S, Denmark Page 4 of 14 5 Environmental data 5.1 Temperature Operating temperature range ....... : -35..70°C Storage temperature range ........... : -40..80°C Altitude Max operating temperature 5.2 < 1500 m 70°C 3000 m 63°C 4500 m 53°C Humidity Operating humidity range ............. : 5 - 95 %RH non condensing Storage humidity range ................. : 5 - 95 %RH non condensing 5.3 Ventilation Forced ventilation is needed dependent on altitude and ambient temperature, as can be see below. Altitude < 1500 m 3000 m 4500 m Ventilate when temperature is: >55°C >48°C >38°C Copyright © KK Wind Solutions A/S, Denmark Page 5 of 14 6 On-board sensors 6.1 Temperature sensor Input range ................................... : -55..125°C Accuracy (-25..100°C) .................... : ±2.0°C Accuracy (-55..125°C) .................... : ±3.0°C 6.2 Real time clock Power backup time ....................... : >14 days XTAL .............................................. : 32768 Hz ± 20 ppm Copyright © KK Wind Solutions A/S, Denmark Page 6 of 14 7 Interfaces 7.1 X1 - Ethernet Speed ....................................... : 100 Mbit/s Full/Half duplex ........................ : Auto-negotiation Feature .................................... : MDI/MDI-X Connector type ........................ : RJ45 Correspond to .......................... : RJ45 cable part Pins 1 2 3 4 5 6 7 8 Case Value TX+ TXRX+ 75R termination 75R termination RX75R termination 75R termination GND Function Ethernet transmit, positive Ethernet transmit, negative Ethernet receive, positive Connected to pin 5, 75R termination to AC common Connected to pin 4, 75R termination to AC common Ethernet receive, negative Connected to pin 8, 75R termination to AC common Connected to pin 7, 75R termination to AC common 7.2 X2 - Console port (RS232) Speed ....................................... : Max 250 kbit/s UART ........................................ : RS232 Connector type ........................ : WAGO 734-163 Correspond to .......................... : WAGO 734-103 Pins 1 2 3 Value GND TX RX Function RS232 transmit data RS232 receive data Copyright © KK Wind Solutions A/S, Denmark Page 7 of 14 7.3 X3 - USB USB Standard ........................... : 2.0 Max 5V load ............................. : 500 mA Connector type ........................ : USB type A receptacle Correspond to .......................... : USB type A plug Pins 1 2 3 4 Case Value V+ DATADATA+ VGND Function Supply voltage USB Data, negative USB Data, positive Supply ground 7.4 X4 & X5 - System bus and supply Input voltage ........................... : 5 VDC ±10%. Power consumption ................. : 5.5 W typical, 10 W @ max load Peak load max .......................... : 3.5 A Max. inrush current.................. : 15A Connector type ........................ : BI62 female Correspond to .......................... : BI62 Pins Value 1..x n.a. 7.5 Function System bus connection to PS60 module X6 - System bus Connector type ........................ : BI62 female Correspond to .......................... : BI62 Pins Value 1..x n.a. Function System bus connection to application and IO modules Copyright © KK Wind Solutions A/S, Denmark Page 8 of 14 8 Communication topology The CM60 can be used in top station and substation configuration. EtherCAT routing is automatically configured on basis of PS60 “Top select” input X3.3-4. 8.1 Top station mode When top station is selected on the PS60 module, the first module to the right of PS60 must be a CM60. EtherCAT ports are configured so PS60 is “the first slave module” in the top level station. The 2 fibre ports are left open in “standalone” solutions, or connected to one or two substations in multi station solutions. 8.2 Substation mode When substation mode is selected, EtherCAT ports are configured for upward connection on fibre channel 1 (X5+X6). The second fibre channel is left open or connected to the next substation. Copyright © KK Wind Solutions A/S, Denmark Page 9 of 14 8.3 Subnet Adding a computer module to a substation, leads to a splitting of the EtherCAT network. Modules to the right of this local computer module are part of a new subnet controlled by this computer. The computer itself is master in the subnet and at the same time a member of the overlying net in a hierarchical manner. Copyright © KK Wind Solutions A/S, Denmark Page 10 of 14 9 LED Indicators Information about the module status is indicated by several LEDs placed the module front. LED Colour Status Means ON POWER Green OFF STATUS Yellow ERROR Red E-CAT LINK Green E-CAT RUN Green E-CAT2 LINK 1 Green E-CAT2 LINK 2 Green E-CAT2 RUN Green ETHERNET LINK Green ETHERNET SPEED Green USB CONNECTOR Red #1 #2 #3 FLICK: BLINK: FLASH: ON BLINK#2 OFF ON OFF ON FLASH#3 OFF FLICK#1 ON #3 FLASH #2 BLINK OFF ON FLASH#3 OFF ON FLASH#3 OFF FLICK#1 ON FLASH#3 BLINK#2 OFF ON FLASH#3 OFF ON OFF ON OFF Supply input present and internal supply OK Supply input missing or internal supply off limit Sotfware running Module error Module OK Link OK Link OK – Data transfer active No link Bootstrap Operational Safe-operational Pre-operational Initialisation Link OK Link OK – Data transfer active No link Link OK Link OK – Data transfer active No link Bootstrap Operational Safe-operational Pre-operational Initialisation Link OK Link OK – Data transfer active No link 100 Mbit/s 10 Mbit/s USB power on USB power off 10 Hz, 50% duty cycle 2.5 Hz, 50% duty cycle 200 ms ON / 1000 ms OFF During boot, STATUS and ERROR LEDs are used to indicate boot program progress. Copyright © KK Wind Solutions A/S, Denmark Page 11 of 14 10 Standards 10.1 EMC standards DS/EN 61000-6-4:2007 ......... : Electromagnetic compatibility - Generic emission standard – Part 6 4: Industrial environment. DS/EN 61000-6-2:2005 ......... : Electromagnetic compatibility - Part 6-2: Generic standards – Immunity for industrial environment. Improved immunity for ESD, Burst and Surge. 10.2 Vibration Vibration random ................. : IEC 60068-2-64 Vibration sine ....................... : IEC 60068-2-6 Bump ................................... : IEC 60068-2-29 Shock ................................... : IEC 60068-2-27 10.3 PLC standards IEC 61131-2:2007 ................. : Programmable controllers - Part 2: Equipment requirements and tests. Copyright © KK Wind Solutions A/S, Denmark Page 12 of 14 11 Mechanical 11.1 Mounting 35mm top hat DIN rail EN 50022 11.2 Dimension and weight Height .................................. : 131 mm Width ................................... : 35 mm Depth ................................... : 179 mm Weight ................................. : 610 g Copyright © KK Wind Solutions A/S, Denmark Page 13 of 14 12 Accessories Connector block - module to module Part number: BI62 Liability note This document has been prepared with care. The product described is, however, constantly under development. For this reason the document may not in every case have been checked for consistency with regards to performance data, standards or other characteristics to the products delivered. In the event that this document contains technical or editorial information not reflected in the products delivered, we reserve the right to make alterations to this document at any time and without prior warning. The data, diagrams, descriptions and other information in this document shall not in any way form the basis of a direct or indirect claim against us if the products have been delivered and the modifications in the products are not reflected in this document. Copyright © KK Wind Solutions A/S, Denmark Page 14 of 14