Introduction
SIRIUS 3RV2 Motor Starter Protectors/
Circuit Breakers up to 40 A
General data
For motor protection
For motor protection with overload relay
function
For starter combinations for export
applications
For transformer protection
For system protection according to
UL 489/CSA C22.2 No. 5-02
For transformer protection according to
UL 489/CSA C22.2 No.5-02
Accessories
Mountable accessories
Busbar accessories
3RV29 infeed system
Rotary operating mechanisms
Mounting accessories
Enclosures and front plates
Overload Relays
General data
SIRIUS 3RU2 Thermal Overload Relays
General data
3RU2 up to 40 A
for standard applications
Accessories
SIRIUS 3RB3 Solid-State Overload Relays
General data
3RB30, 3RB31 up to 40 A
for standard applications
Accessories
Technical Information
can be found at
www.siemens.com/industrial-controls/
support
under Product List:
- Technical specifications
under Entry List:
- Updates
- Download
- FAQ
- Manuals
- Characteristics
- Certificates
SIRIUS Innovations Supplement 2012
Protection Equipment
Introduction
■ Overview
Type
3RV20
3RV21
3RV23
3RV24
3RV27
3RV28
✓
SIRIUS 3RV2 motor starter protectors and circuit breakers up to 40 A
Uses
System protection
✓1)
✓1)
--
--
✓
Motor protection
✓
--
--
--
--
--
Motor protection with
overload relay function
--
✓
--
--
--
--
Starter combinations
--
--
✓
--
--
--
Transformer protection
--
--
--
✓
✓
✓
Size
S00, S0
S00, S0
S00, S0
S00, S0
S00
S00
A
A
Up to 16
Up to 40
Up to 16
Up to 32
Up to 16
Up to 40
Up to 16
Up to 25
Up to 15
--
Up to 15
--
Rated operational voltage Ue
acc. to IEC
V
690 AC2)
690 AC2)
690 AC2)
690 AC2)
690 AC
690 AC
Rated frequency
Hz
50/60
50/60
50/60
50/60
50/60
50/60
CLASS 10
CLASS 10
--
CLASS 10
--
--
0.11 ... 0.16
to
34 ... 40
0.11 ... 0.16
to
27 ... 32
None3)
0.11 ... 0.16
to
20 ... 25
0.16 ... 15
nonadjustable
0.16 ... 15
nonadjustable
13 times
13 times
13 times
20 times
13 times
20 times
Short-circuit breaking capacity kA
Icu at 480 V AC/600 V AC
12/50/65/30
50/65
12/50/65
55/100
4)
4)
Pages
5/12, 5/13
5/14
5/15
5/16
5/17
5/18
5
Rated current In
Size S00
Size S0
Trip class
Thermal
overload release
A
A
Electronic releases
A multiple of the
rated current
Accessories
For sizes
S00
S0
S00
S0
S00 S0
S00 S0
S00
S00
Auxiliary switches
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
Signaling switches
✓
✓
✓
✓
✓
✓
✓
✓
--
--
Undervoltage releases
✓
✓
--
--
✓
✓
✓
✓
✓
✓
Shunt releases
✓
✓
--
--
✓
✓
✓
✓
✓
✓
Isolator modules
✓
✓
✓
✓
✓
✓
✓
✓
--
--
Insulated three-phase
busbar system
✓
✓
--
--
✓
✓
✓
✓
--
--
Busbar adapters
✓
✓
✓
✓
✓
✓
✓
✓
--
--
Door-coupling rotary operating
mechanisms
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
Link modules
✓
✓
✓
✓
✓
✓
✓
✓
--
--
Enclosures for surface
mounting
✓
✓
✓
✓
✓
✓
✓
✓
--
--
Enclosures for flush mounting
✓
✓
✓
✓
✓
✓
✓
✓
--
--
Front plates
✓
✓
✓
✓
✓
✓
✓
✓
--
--
Infeed system
✓
✓
--
--
✓
✓
✓
✓
--
--
Terminal covers for ring
lug terminal connections
--5)
--5)
--
--
--
--
--
--
--
--
Sealable scale covers
for setting knobs
✓
✓
✓
✓
--
--
✓
✓
--
--
Pages
5/19 ... 5/35
✓ Has this function or can use this accessory
-- Does not have this function or cannot use this accessory
1)
For symmetrical loading of the three phases.
2)
With molded-plastic enclosure 500 V AC.
3) For overload protection of the motors, appropriate overload relays must be
used.
5/2
SIRIUS Innovations Supplement 2012
4)
According to UL 489 at 480 Y/277 V AC: 65 kA.
According to CSA 22.2 no .05 @ 600 Y/347 V AC: 10 KA
5)
Terminal covers are available for 3RV20 motor starter protectors with ring
lug terminal connection for motor protection.
Protection Equipment
Introduction
■ Overview
FLA Adjustment
Range
3RV2023
3RV2021
3RV2011
Single Phase HP
Ratings
Three Phase HP Ratings
115V
200V
230V
230V
Instantaneous CSA SCCR kA Order No.
Overcurrent
600Y/347V
Release
460V
575V
A
kA
3RV20/21/23
0.11-0.16
--
--
-
--
-
--
2.1
30kA
3RV2011-0AA10
0.14-0.2
--
--
--
--
--
--
2.6
30kA
3RV2011-0BA10
0.18-0.25
--
--
--
--
--
--
3.3
30kA
3RV2011-0CA10
0.22-0.32
--
--
--
--
--
--
4.2
30kA
3RV2011-0DA10
0.28-0.4
--
--
--
--
--
--
5.2
30kA
3RV2011-0EA10
0.35-0.5
--
--
--
--
--
--
6.5
30kA
3RV2011-0FA10
0.45-0.63
--
--
--
--
--
--
8.2
30kA
3RV2011-0GA10
0.55-0.8
--
--
--
--
--
1/2
10
30kA
3RV2011-0HA10
0.7-1
--
--
--
--
--
1/2
13
30kA
3RV2011-0JA10
0.9-1.25
--
--
--
--
1/2
1/2
16
30kA
3RV2011-0KA10
1.1-1.6
--
1/10
--
--
3/4
3/4
21
30kA
3RV2011-1AA10
1.4-2
--
1/8
--
--
3/4
1
26
30kA
3RV2011-1BA10
1.8-2.5
--
1/6
1/2
1/2
1
1 1/2
33
30kA
3RV2011-1CA10
2.2-3.2
1/10
1/4
1/2
3/4
1 1/2
2
42
30kA
3RV2011-1DA10
2.8-4
1/8
1/3
3/4
3/4
2
3
52
30kA
3RV2011-1EA10
3.5-5
1/6
1/2
1
1
3
3
65
30kA
3RV2011-1FA10
4.5-6.3
1/4
1/2
1
1 1/2
3
5
82
30kA
3RV2011-1GA10
5.-8
1/3
1
2
2
5
5
104
30kA
3RV2011-1HA10
7-10
1/2
1 1/2
2
3
5
7 1/2
130
30kA
3RV2011-1JA10
9-12.5
1/2
2
3
3
7 1/2
10
163
30kA
3RV2011-1KA10
11-16
1
2
5
5
10
--
208
30kA
3RV2011-4AA10
5
3RV2011 Size S001)
3RV2021 Size S01)
11-16
1
2
3
5
10
--
208
--
3RV2021-4AA10
14-20
1 1/2
3
5
5
10
--
260
--
3RV2021-4BA10
17-22
1 1/2
3
5
7 1/2
15
--
286
--
3RV2021-4CA10
20-25
2
3
5
7 1/2
15
--
325
--
3RV2021-4DA10
23-28
2
5
7 1/2
10
20
--
364
--
3RV2021-4UA10
27-32
2
5
7 1/2
10
20
--
400
--
3RV2021-4EA10
30-36
3
5
10
10
25
--
432
--
3RV2021-4PA10
34-40
3
7 1/2
10
10
30
--
480
--
3RV2021-4FA10
3RV2023 Size S01)
600V AC
9-12.5
--
--
--
--
--
--
CS /UL
--
3RV2023-1KA10
11-16
--
--
--
--
--
--
CS /UL
--
3RV2023-4AA10
14-20
--
Availability and Data to be announced
--
CS /UL
--
3RV2023-4BA10
17-22
--
--
--
--
--
--
CS /UL
--
3RV2023-4CA10
20-25
--
--
--
--
--
--
CS /UL
--
3RV2023-4DA10
1)
For further technical data and completion of the part numbers, refer to
page 5/12.
SIRIUS Innovations Supplement 2012
5/3
Protection Equipment
Introduction
((
Type
))
3RU21
3RB30
3RB31
System protection
✓1)
✓1)
✓1)
Motor protection
✓
✓
✓
Alternating current, three-phase
✓
✓
✓
Alternating current, single-phase
✓
--
--
SIRIUS overload relays up to 40 A
5
Uses
Direct current
✓
--
--
Size of contactor
S00, S0
S00, S0
S00, S0
Rated operational current Ie
Size S00
Size S0
A
A
Up to 16
Up to 40
Up to 16
Up to 40
Up to 16
Up to 40
Rated operational voltage Ue
V
690 AC
690 AC
690 AC
Rated frequency
Hz
50/60
50/60
50/60
CLASS 10
CLASS 10, 20
CLASS 5, 10, 20, 30
adjustable
--
--
A
0.11 ... 0.16
to
34 ... 40
A
--
0.1 ... 0.4
to
10 ... 40
0.1 ... 0.4
to
10 ... 40
0.04 ... 18.5
0.04 ... 18.5
0.04 ... 18.5
5/45, 5/46
5/54, 5/55
5/56
For sizes
S00
S0
S00
S0
S00
S0
Terminal brackets for stand-alone
installation
✓
✓
✓
✓
✓
✓
Trip class
Thermal
overload release
Solid-state
overload release
A
A
Rating for induction motor at
400 V AC
kW
Pages
Accessories
Mechanical RESET
✓
✓
✓
✓
✓
✓
Cable releases for RESET
✓
✓
✓
✓
✓
✓
Electrical remote RESET
✓
✓
--
--
Integrated in the unit
Terminal covers for ring lug terminal
connections
--2)
--2)
--
--
--
--
Sealable covers
for setting knobs
✓
✓
✓
✓
✓
✓
Pages
5/47, 5/48
✓ Has this function or can use this accessory
-- Does not have this function or cannot use this accessory
5/4
SIRIUS Innovations Supplement 2012
5/57, 5/58
5/57, 5/58
1)
The units are responsible in the main circuit for overload protection of the
assigned electrical loads (e.g. motors), starter cable and other switching
and protection devices in the respective motor starter.
2)
Terminal covers for ensuring finger-safe touch protection are available for
3RU21 overload relays with ring lug terminal connections for mounting
onto contactors.
Protection Equipment
5
Notes
SIRIUS Innovations Supplement 2012
5/5
SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A
General data
■ Overview
The following illustration shows our 3RV2 motor starter protectors with the accessories which can be mounted for the various
sizes, see also "Introduction" --> "Overview" on page 5/2.
For accessories, see page 5/19 onwards.
7
Mountable accessories
8
1 Transverse auxiliary switch
2 Lateral auxiliary switch with 2 contacts
3 Lateral auxiliary switch with 4 contacts
4 Shunt release
3
5 Undervoltage release without/with
leading contacts
2
6 Signaling switch
7 Isolator module
8 Terminal block type E
NSB0_02076
6
4
5
1
5
Mountable accessories for 3RV2 motor starter protectors
Type of construction
The motor starter protectors are available in 2 sizes:
• Size S00 - width 45 mm,
max. rated current 16 A,
at 460 V AC suitable for induction motors up to 10 HP.
• Size S0 - width 45 mm,
max. rated current 40 A,
at 460 V AC suitable for induction motors up to 30 HP.
Note
Screw terminals
Spring-type terminals
Ring lug terminal connection
Motor starter protectors with spring-type terminals, size S0 (left) and
motor starter protectors with screw terminals, size S00 (right)
The new 3RV2 motor starter protectors are compact, current limiting motor starter protectors which are optimized for motor
starters. The motor starter protectors are used for switching and
protecting three-phase induction motors of up to 30 HP at
460 V AC and for other loads with rated currents of up to 40 A.
5/6
SIRIUS Innovations Supplement 2012
These terminals are indicated in the corresponding
tables by the symbols shown on orange
backgrounds.
"Increased safety" type of protection EEx e according to
ATEX directive 94/9/EC
The 3RV20 motor starter protectors are suitable for the overload
protection of explosion-proof motors with "increased safety" type
of protection EEx e; see Chapter 9 "Appendix" --> "Standards
and Approvals" --> "Type Overview of Approved Devices for
Explosion-Protected Areas (ATEX Explosion Protection)".
SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A
General data
■ Application
motor to be protected is always paramount to the choice of the
most suitable motor starter protector. This also applies to motor
starter protectors for transformer protection.
Operating conditions
3RV2 motor starter protectors are suitable for use in any climate.
They are intended for use in enclosed rooms in which no severe
operating conditions (such as dust, caustic vapors, hazardous
gases) prevail. When installed in dusty and damp areas, suitable
enclosures must be provided.
Possible uses
The 3RV2 motor starter protectors can be used:
• For short-circuit protection
• For motor protection (also with overload relay function)
• For system protection
• For short-circuit protection for starter combinations
• For transformer protection
• As main and EMERGENCY-STOP switches
• For operation in IT systems (IT networks)
• For switching of DC currents
• In areas subject to explosion hazard (ATEX)
3RV2 motor starter protectors can optionally be fed from the top
or from below.
The permissible ambient temperatures, the maximum switching
capacities, the tripping currents and other boundary conditions
can be found in the technical specifications and tripping characteristics, see note on Technical Information on page 5/1.
3RV2 motor starter protectors are suitable for operation in IT
systems (IT networks). In this case, the different short-circuit
breaking capacity in the IT system must be taken into account.
Since operational currents, starting currents and current peaks
are different even for motors with identical power ratings due to
the inrush current, the motor ratings in the selection tables are
only guide values. The specific rated and start-up data of the
For more information see the note on Technical Information on
page 5/1.
■ More information
Order No. scheme
Motor starter protector
1st 3rd
4th
5th
6th
7th
@@@
@
@
@
@
8th
9th
10th
11th
12th
@
@
@
@
@
@
@
16th
–
–
@
@
@
@
@
@
@
@
3RV
SIRIUS 2nd generation
2
@
Type of motor starter protector
@
Size
@
Switching capacity
Setting range for overload release
@
Trip class (CLASS)
@
Connection method
@
With or without auxiliary switch
Special versions
Example
13th 14th 15th
5
Digit of the Order No.
3RV
2
0
1
1
–
1
A
A
1
0
Note:
The Order No. scheme is presented here merely for information
purposes and for better understanding of the logic behind the
order numbers.
For your orders, please use the order numbers quote in the
catalog under the Selection and ordering data section.
SIRIUS Innovations Supplement 2012
5/7
SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A
General data
General technical specifications
3RV2. 1
3RV27 11, 3RV28 11
3RV2. 2
S00
S00
S0
45 x 97 x 91
45 x 109 x 91
45 x 144 x 92
--
45 x 97 x 91
45 x 119 x 91
H
Type
Size
W
mm
mm
D
Dimensions (W x H x D)
• Screw terminals
• Spring-type terminals
Standards
• IEC 60947-1, EN 60947-1 (VDE 0660 Part 100)
• IEC 60947-2, EN 60947-2 (VDE 0660 Part 101)
• IEC 60947-4-1, EN 60947-4-1 (VDE 0660 Part 102)
• UL 489, CSA C22.2-No.5-02
Yes
Yes
Yes
Yes
3
Number of poles
A
16
°C
°C
°C
–50 ... +80
–20 ... +701)
–20 ... +402)
Permissible rated current at inside temperature of control cabinet
• +60 °C
• +70 °C
%
%
100
87
Permissible rated current at ambient temperature of enclosure
(applies to motor starter protectors inside enclosure d 32 A)
• +35 °C
• +60 °C
%
%
100
87
Rated operational voltage Ue
• Acc. to IEC
• Acc. to UL/CSA
V AC
V AC
6903)
600
Rated frequency
Hz
50/60
Rated insulation voltage Ui
V
690
Rated impulse withstand voltage Uimp
kV
6
Max. rated current In max
(= max. rated operational current Ie)
5
Permissible ambient temperature
• Storage/transport
• Operation
In: 0.16 ... 32 A
In: 36 ... 40 A
Utilization category
• IEC 60947-2 (motor starter protector/circuit breaker)
• IEC 60947-4-1 (motor starter)
Trip class CLASS
40
A
AC-3
Acc. to IEC 60947-4-1
DC short-circuit breaking capacity (time constant t = 5 ms)
• 1 conducting path 150 V DC
• 2 conducting paths in series 300 V DC
• 3 conducting paths in series 450 V DC
10
kA
kA
kA
10
10
10
In: 0.16 ... 0.63 A
In: 0.8 ... 6.3 A
In: 8 ... 16 A
W
W
W
5
6
7
In: 16 A
W
--
7
In: 20 ... 25 A
In: 28 ... 32 A
In: 36 ... 40 A
W
W
W
----
8
11
14
Shock resistance
Acc. to IEC 60068-2-27
g/ms
25/11 (square and sine pulse)
Degree of protection
Touch protection
Acc. to IEC 60529
Acc. to EN 50274
Temperature compensation
Acc. to IEC 60947-4-1
Phase failure sensitivity
Acc. to IEC 60947-4-1
Power loss Pv for each motor starter
protector
Dependent on the
rated current In
(upper setting range)
P
R percurrentpath = ------------, 2u 3
IP204)
Finger-safe
°C
–20 ... +60
Yes
Explosion protection – safe operation of motors with
"increased safety" type of protection
Yes for 3RV20
EC type test certificate number according to
directive 94/9/EC (ATEX)
On request
Isolating function
Main and EMERGENCY-STOP switch
characteristics5)
Acc. to IEC 60947-2
Acc. to IEC 60204-1
(VDE 0113)
Protective separation between
main and auxiliary circuits,
required for PELV applications
• Up to 400 V + 10 %
• Up to 415 V + 5 % (higher voltage on request)
Acc. to EN 60947-1
Yes
Yes
Yes
Yes
Any, acc. to IEC 60447 start command "I" right-hand side or top
Permissible mounting position
Mechanical endurance
Operating cycles 100 000
Electrical endurance
Operating cycles 100 000
Max. switching frequency per hour (motor starts)
1)
Over +60 °C current reduction.
2)
The devices must not be mounted side-by-side and they must not be
assembled with link modules with contactors. A lateral clearance of 9 mm
is required.
3)
With molded-plastic enclosure 500 V.
Terminal compartment IP00 (exception: 3RV20 11-..2. motor starter
protectors with spring-type terminals in degree of protection IP20).
4)
5/8
SIRIUS Innovations Supplement 2012
1/h
15
5)
With appropriate accessories.
SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A
General data
Rated data of the auxiliary switches and signaling switches
Lateral
auxiliary switch
with
1 NO + 1 NC,
2 NO, 2 NC,
2 NO + 2 NC
Signaling
switch
Transverse
auxiliary switch with
1 CO
1 NO + 1 NC,
2 NO
Max. Rated voltage
• Acc. to NEMA (UL)
V AC
600
• Acc. to NEMA (CSA)
V AC
600
Uninterrupted current
A
10
10
5
2.5
1 NO + 1 NC,
2 NO, 2 NC:
A600, Q300;
2 NO + 2 NC:
A300, Q300
A600, Q300
B600, R300
C300, R300
Switching capacity
250
250
Front transverse auxiliary switches
Switching capacity for different voltages
1 CO
1 NO + 1 NC, 2 NO
• At AC-15, alternating voltage
- 24 V
- 230 V
- 400 V
- 690 V
A
A
A
A
4
3
1.5
0.5
2
0.5
---
• At AC-12 = Ith, alternating voltage
- 24 V
- 230 V
- 400 V
- 690 V
A
A
A
A
10
10
10
10
2.5
2.5
---
• At DC-13, direct voltage L/R 200 ms
- 24 V
- 48 V
- 60 V
- 110 V
- 220 V
A
A
A
A
A
1
--0.22
0.1
1
0.3
0.15
---
V
mA
17
1
Minimum load capacity
5
Rated operational current Ie
Front transverse solid-state compatible auxiliary switches
Switching capacity for different voltages
1 CO
V
125
A
0.1
V
60
Rated operational current Ie/DC-13 at Ue = 60 V
A
0.3
Minimum load capacity
V
mA
5
1
Rated operational voltage Ue
Alternating voltage
Rated operational current Ie/AC-14 at Ue = 125 V
Rated operational voltage Ue
Direct voltage L/R 200 ms
Lateral auxiliary switches with signaling switch
Switching capacity for different voltages:
Lateral auxiliary switch with 1 NO + 1 NC, 2 NO, 2 NC, 2 NO + 2 NC;
Signaling switches
Rated operational current Ie
• At AC-15, alternating voltage
- 24 V
- 230 V
- 400 V
- 690 V
A
A
A
A
6
4
3
1
• At AC-12 = Ith, alternating voltage
- 24 V
- 230 V
- 400 V
- 690 V
A
A
A
A
10
10
10
10
• At DC-13, direct voltage L/R 200 ms
- 24 V
- 110 V
- 220 V
- 440 V
A
A
A
A
2
0.5
0.25
0.1
V
mA
17
1
Minimum load capacity
SIRIUS Innovations Supplement 2012
5/9
SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A
General data
Auxiliary releases
Undervoltage releases
Shunt releases
Power consumption
• During pick-up
- AC voltages
- DC voltages
VA/W
W
20.2/13
20
20.2/13
13 ... 80
• During uninterrupted duty
- AC voltages
- DC voltages
VA/W
W
7.2/2.4
2.1
---
• Tripping
V
0.35 ... 0.7 x Us
0.7 ... 1.1 x Us
• Pickup
V
0.85 ... 1.1 x Us
--
Maximum opening time
ms
20
Melting fuses gG
A
10
Miniature circuit breaker, C characteristic
A
61)
Response voltage
Short-circuit protection for auxiliary and control circuits
1)
Prospective short-circuit current < 0.4 kA.
Type
3RV2. 11
3RV2. 21
3RV27 11, 3RV28 11
Size
S00
S0
S00
Width
45 mm
45 mm
45 mm
Conductor cross-sections of main circuit
Screw terminals
M3, Pozidriv size 2
M4, Pozidriv size 2
M4, Pozidriv size 2
Operating devices
mm
‡ 5 ... 6
‡ 5 ... 6
‡ 5 ... 6
Prescribed tightening torque
Nm
0.8 ... 1.2
2 ... 2.5
2.5 ... 3
• Solid
mm2
2 x (0.75 ... 2.5)1),
2x4
2 x (1 ... 2.5)1),
2 x (2.5 ... 10)1)
1 ... 10,
max. 2 x 10
• Stranded
mm2
2 x (0.75 ... 2.5)1),
2x4
2 x (1 ... 2.5)1),
2 x (2.5 ... 10)1)
1.5 ... 25,
max. 10 + 25
• Finely stranded with end sleeves (DIN 46228 T1)
mm2
2 x (0.5 ... 1.5)1),
2 x (0.75 ... 2.5)1)
2 x (1 ... 2.5)1),
2 x (2.5 ... 6)1),
1 x 10
1 ... 16,
max. 6 + 16
• AWG cables, solid or stranded
AWG
2 x (18 ... 14)1),
2 x 12
2 x (16 ... 12)1),
2 x (14 ... 8)1)
2 x (14 ... 10)
Terminal screw
Conductor cross-sections (min./max.),
1 or 2 conductors can be connected
Connection type spring-type terminals
Spring-type terminals
mm
3.0 x 0.5 and 3.5 x 0.5
• Solid
mm2
2 x (0.5 ... 4)
2 x (1 ... 10)
--
• Finely stranded without end sleeve
mm2
2 x (0.5 ... 2.5)
2 x (1 ... 6)
--
• Finely stranded with end sleeves (DIN 46228 T1)
mm2
2 x (0.5 ... 2.5)
2 x (1 ... 6)
--
• AWG cables, solid or stranded
AWG
2 x (20 ... 12)
2 x (18 ... 8)
--
Max. external diameter of the conductor insulation
mm
3.6
3.6
--
Operating devices
Conductor cross-sections (min./max.),
1 or 2 conductors can be connected
Ring lug terminal connection
Connection type ring lug terminals
M3, Pozidriv size 2
M4, Pozidriv size 2
--
Operating devices
mm
‡ 5 ... 6
‡ 5 ... 6
--
Prescribed tightening torque
Nm
0.8 ... 1.2
2 ... 2.5
--
mm
d2 = min. 3.2,
d3 = max. 7.5
d2 = min. 4.3,
d3 = max. 12.2
--
Terminal screw
Usable ring lug terminals
• DIN 46234 without insulation sleeve
d3
d2
• DIN 46225 without insulation sleeve
• DIN 46237 with insulation sleeve
• JIS C2805 Type R without insulation sleeve
• JIS C2805 Type RAV with insulation sleeve
• JIS C2805 Type RAP with insulation sleeve
1)
If two different conductor cross-sections are connected to one clamping
point, both cross-sections must lie in the range specified. If identical crosssections are used, this restriction does not apply.
5/10
SIRIUS Innovations Supplement 2012
I2_12740
5
Connection type screw terminals
SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A
General data
Type
3RV2. 11
3RV2. 21
3RV27 11, 3RV28 11
Size
S00
S0
S00
Width
45 mm
45 mm
45 mm
Conductor cross-sections for auxiliary and control circuits
Connection type screw terminals
Screw terminals
M3, Pozidriv size 2
Terminal screw
Operating devices
mm
‡ 5 ... 6
Prescribed tightening torque
Nm
0.8 ... 1.2
• Solid or stranded
mm2
2 x (0.5 ... 1.5)1), 2 x (0.75 ... 2.5)1)
• Finely stranded with end sleeves (DIN 46228 T1)
mm2
2 x (0.5 ... 1.5)1), 2 x (0.75 ... 2.5)1)
• AWG cables, solid or stranded
AWG
2 x (18 ... 14)1), 2 x (20 ... 16)1)
Conductor cross-sections (min./max.),
1 or 2 conductors can be connected
Connection type spring-type terminals
Spring-type terminals
mm
3.0 x 0.5 and 3.5 x 0.5
• Solid
mm2
2 x (0.5 ... 2.5)
• Finely stranded without end sleeve
mm2
2 x (0.5 ... 1.5)
• Finely stranded with end sleeves (DIN 46228 T1)
mm2
2 x (0.5 ... 1.5)
• AWG cables, solid or stranded
AWG
2 x (20 ... 14)
Max. external diameter of the conductor insulation
mm
3.6
Operating devices
Conductor cross-sections (min./max.),
1 or 2 conductors can be connected
Connection type ring lug terminals
Ring lug terminal connection
mm
‡ 5 ... 6
Tightening torque
Nm
0.8 ... 1.2
mm
d2 = min. 3.2, d3 = max. 7.5
Usable ring lug terminals
• DIN 46234 without insulation sleeve
d3
d2
5
M3, Pozidriv size 2
Terminal screw
Operating devices
• DIN 46225 without insulation sleeve
• DIN 46237 with insulation sleeve
• JIS C2805 Type RAV with insulation sleeve
• JIS C2805 Type RAP with insulation sleeve
1)
I2_12740
• JIS C2805 Type R without insulation sleeve
If two different conductor cross-sections are connected to one clamping
point, both cross-sections must lie in the range specified. If identical crosssections are used, this restriction does not apply.
SIRIUS Innovations Supplement 2012
5/11
SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A
Motor Starter Protectors
For motor protection
■ Selection and ordering data
CLASS 10, without auxiliary switches1)
The 3RV20 can also be used as Type E self-protected manual
combination starters per CSA 22.2 without the use of an additional type E terminal adapter. See page 5/23 and 5/31.
The 3RV20 1 & 3RV20 2 MSP's can be used as components in
Group Installation per NEC 430-53(C) to turn motors on and off.
Each device has built-in heater elements that provide overload
protection and magnetic trip elements to protect the motor.
When the 3RV2 is used as a component in Group Installation,
multiple MSP's can be installed below one circuit breaker to protect its own motor. A contactor can be mounted to the MSP to
provide a remotely operated starter.
3RV20 11-0AA10
Suitable
for
induction
motors2)
at 600 V
Setting range
for thermal
overload
release
Instantaneous
electronic
releases
In
I
A
HP
v
5
Rated
current
3RV20 11-0EA20
Short-circuit
Breaking
Capacity at
460 V AC
in Group
Installation
Short-circuit
Breaking
Capacity at
600 V AC
in Group
Installation
Icu
3RV20 21-4AA10
Screw terminals
3RV20 21-4AA20
Weight
approx.
Order No.
A
A
kA
kA
Spring-type
terminals
Weight
approx.
Order No.
kg
kg
Size S00
0.16
0.2
0.25
0.32
-----
0.11 ... 0.16
0.14 ... 0.2
0.18 ... 0.25
0.22 ... 0.32
2.1
2.6
3.3
4.2
65
65
65
65
30
30
30
30
3RV20 11-0AA10
3RV20 11-0BA10
3RV20 11-0CA10
3RV20 11-0DA10
0.260
0.260
0.260
0.260
3RV20 11-0AA20
3RV20 11-0BA20
3RV20 11-0CA20
3RV20 11-0DA20
0.280
0.290
0.290
0.280
0.4
0.5
0.63
0.8
-----
0.28 ... 0.4
0.35 ... 0.5
0.45 ... 0.63
0.55 ... 0.8
5.2
6.5
8.2
10
65
65
65
65
30
30
30
30
3RV20 11-0EA10
3RV20 11-0FA10
3RV20 11-0GA10
3RV20 11-0HA10
0.260
0.260
0.260
0.260
3RV20 11-0EA20
3RV20 11-0FA20
3RV20 11-0GA20
3RV20 11-0HA20
0.290
0.290
0.280
0.280
1
1.25
1.6
2
1/2
1/2
3/4
1
0.7 ... 1
0.9 ... 1.25
1.1 ... 1.6
1.4 ... 2
13
16
21
26
65
65
65
65
30
30
30
30
3RV20 11-0JA10
3RV20 11-0KA10
3RV20 11-1AA10
3RV20 11-1BA10
0.320
0.320
0.320
0.320
3RV20 11-0JA20
3RV20 11-0KA20
3RV20 11-1AA20
3RV20 11-1BA20
0.350
0.350
0.350
0.350
2.5
3.2
4
5
1.5
2
3
3
1.8 ... 2.5
2.2 ... 3.2
2.8 ... 4
3.5 ... 5
33
42
52
65
65
65
65
65
30
30
30
30
3RV20 11-1CA10
3RV20 11-1DA10
3RV20 11-1EA10
3RV20 11-1FA10
0.320
0.330
0.320
0.330
3RV20 11-1CA20
3RV20 11-1DA20
3RV20 11-1EA20
3RV20 11-1FA20
0.350
0.350
0.350
0.350
6.3
8
10
12.5
16
5
5
7.5
10
--
4.5 ... 6.3
5.5 ... 8
7 ... 10
9 ... 12.5
11 ... 16
82
104
130
163
208
65
65
65
65
65
30
30
30
30
---
3RV20 11-1GA10
3RV20 11-1HA10
3RV20 11-1JA10
3RV20 11-1KA10
3RV20 11-4AA10
0.330
0.330
0.330
0.330
0.340
3RV20 11-1GA20
3RV20 11-1HA20
3RV20 11-1JA20
3RV20 11-1KA20
3RV20 11-4AA20
0.360
0.360
0.360
0.360
0.360
---------------------------
3RV20 21-4AA10
3RV20 21-4BA10
3RV20 21-4CA10
3RV20 21-4DA10
3RV20 21-4NA10
3RV20 21-4EA10
3RV20 21-4PA10
3RV20 21-4FA10
3RV2023-1KA10
3RV2023-4AA10
3RV2023-4BA10
3RV2023-4CA10
3RV2023-4DA10
0.340
0.340
0.340
0.340
0.350
0.350
0.360
0.360
-------------------------------
3RV20 21-4AA20
3RV20 21-4BA20
3RV20 21-4CA20
3RV20 21-4DA20
3RV20 21-4NA20
3RV20 21-4EA20
--3RV2023-1KA20
3RV2023-4AA20
3RV2023-4BA20
3RV2023-4CA20
3RV2023-4DA20
0.390
0.400
0.390
0.400
0.410
0.410
Size S0
16
20
22
25
28
32
36
40
-3) -----
-11 ... 16
208
65
-14 ... 20
260
65
-17 ... 22
286
65
-20 ... 25
325
65
-23 ... 28
364
50
-27 ... 32
400
50
-30 ... 36
432
12
-34 ... 40
480
12
-9 ... 12.5
----11 ... 16
----14 ... 20
----17 ... 22
----20 ... 25
---1) The 3RV20 .1-..A.0 motor starter protectors up to 32 A are also available
with ring lug terminal connection. The Order No. must be changed in the
11th position to "4": e. g. 3RV20 11-0AA40.
2)
Guide value for 4-pole standard motors at AC 60 Hz 460 V. Select MSP by
motor full load amps. Horsepower ratings for reference only.
Auxiliary switches can be ordered separately
(see "Mountable accessories").
3)
Availability and data to be announced.
5/12
SIRIUS Innovations Supplement 2012
--------------------------
SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A
Motor Starter Protectors
For motor protection
CLASS 10, with transverse auxiliary switch (1 NO + 1 NC)
3RV20 11-4AA15
with integrated transverse auxiliary switch
Suitable
for
induction
motors2)
at 600 V
Setting range
for thermal
overload
release
Instantaneous
electronic
releases
In
I
A
HP
v
Rated
current
The 3RV20 can also be used as Type E self-protected manual
combination starters per CSA 22.2 without the use of an additional type E terminal adapter. See page 5/23 and 5/31.
3RV20 11-0EA25
with integrated transverse auxiliary switch
Short-circuit
Breaking
Capacity at
460 V AC
in Group
Installation
Short-circuit
Breaking
Capacity at
600 V AC
in Group
Installation
Icu
3RV20 21-4AA15
with integrated transverse auxiliary switch
Screw terminals
3RV20 21-4AA25
with integrated transverse auxiliary switch
Weight
approx.
Order No.
A
A
kA
kA
Spring-type
terminals
Weight
approx.
5
The 3RV20 1 & 3RV20 2 MSP's can be used as components in
Group Installation per NEC 430-53(C) to turn motors on and off.
Each device has built-in heater elements that provide overload
protection and magnetic trip elements to protect the motor.
When the 3RV2 is used as a component in Group Installation,
multiple MSP's can be installed below one circuit breaker to protect its own motor. A contactor can be mounted to the MSP to
provide a remotely operated starter.
Order No.
kg
kg
Size S00
0.16
0.2
0.25
0.32
-----
0.11 ... 0.16
0.14 ... 0.2
0.18 ... 0.25
0.22 ... 0.32
2.1
2.6
3.3
4.2
65
65
65
65
30
30
30
30
3RV20 11-0AA15
3RV20 11-0BA15
3RV20 11-0CA15
3RV20 11-0DA15
0.280
0.280
0.280
0.280
3RV20 11-0AA25
3RV20 11-0BA25
3RV20 11-0CA25
3RV20 11-0DA25
0.300
0.310
0.310
0.300
0.4
0.5
0.63
0.8
-----
0.28 ... 0.4
0.35 ... 0.5
0.45 ... 0.63
0.55 ... 0.8
5.2
6.5
8.2
10
65
65
65
65
30
30
30
30
3RV20 11-0EA15
3RV20 11-0FA15
3RV20 11-0GA15
3RV20 11-0HA15
0.280
0.280
0.280
0.280
3RV20 11-0EA25
3RV20 11-0FA25
3RV20 11-0GA25
3RV20 11-0HA25
0.310
0.310
0.300
0.300
1
1.25
1.6
2
1/2
1/2
3/4
1
0.7 ... 1
0.9 ... 1.25
1.1 ... 1.6
1.4 ... 2
13
16
21
26
65
65
65
65
30
30
30
30
3RV20 11-0JA15
3RV20 11-0KA15
3RV20 11-1AA15
3RV20 11-1BA15
0.340
0.340
0.340
0.340
3RV20 11-0JA25
3RV20 11-0KA25
3RV20 11-1AA25
3RV20 11-1BA25
0.370
0.370
0.370
0.370
2.5
3.2
4
5
1.5
2
3
3
1.8 ... 2.5
2.2 ... 3.2
2.8 ... 4
3.5 ... 5
33
42
52
65
65
65
65
65
30
30
30
30
3RV20 11-1CA15
3RV20 11-1DA15
3RV20 11-1EA15
3RV20 11-1FA15
0.340
0.350
0.340
0.350
3RV20 11-1CA25
3RV20 11-1DA25
3RV20 11-1EA25
3RV20 11-1FA25
0.370
0.370
0.370
0.370
6.3
8
10
12.5
16
5
5
7.5
10
--
4.5 ... 6.3
5.5 ... 8
7 ... 10
9 ... 12.5
11 ... 16
82
104
130
163
208
65
65
65
65
65
30
30
30
30
---
3RV20 11-1GA15
3RV20 11-1HA15
3RV20 11-1JA15
3RV20 11-1KA15
3RV20 11-4AA15
0.350
0.350
0.350
0.350
0.360
3RV20 11-1GA25
3RV20 11-1HA25
3RV20 11-1JA25
3RV20 11-1KA25
3RV20 11-4AA25
0.380
0.380
0.380
0.380
0.380
16
20
22
25
-----
11 ... 16
14 ... 20
17 ... 22
20 ... 25
208
260
286
325
65
65
65
65
---------
3RV20 21-4AA15
3RV20 21-4BA15
3RV20 21-4CA15
3RV20 21-4DA15
0.360
0.360
0.360
0.360
3RV20 21-4AA25
3RV20 21-4BA25
3RV20 21-4CA25
3RV20 21-4DA25
0.410
0.420
0.410
0.420
28
32
36
40
-----
23 ... 28
27 ... 32
30...36
34...40
364
400
432
480
50
50
12
12
---------
3RV20 21-4NA15
3RV20 21-4EA15
3RV20 21-4PA15
3RV20 21-4FA15
0.370
0.370
0.380
0.380
3RV20 21-4NA25
3RV20 21-4EA25
---
0.430
0.430
Size S0
1)
Guide value for 4-pole standard motors at AC 60 Hz 460 V. Select MSP by
motor full load amps. Horsepower ratings for reference only.
Auxiliary switches can be ordered separately
(see "Mountable accessories").
SIRIUS Innovations Supplement 2012
5/13
SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A
Motor Starter Protectors
For motor protection with overload relay function
■ Selection and ordering data
CLASS 10, with overload relay function (automatic RESET), without auxiliary switches
Rated
current
Suitable for
induction
motors1)
at 480 V
Suitable for
induction
motors1)
at 600 V
3RV21 21-4BA10
Setting range
Thermal overload
releases
Instantaneous
electronic
releases
In
I
A
Short-circuit
breaking
capacity
at 480 V AC
v
3RV21 11-0FA10
Short-circuit
breaking
capacity
at 600 V AC
Screw terminals
Icu
Order No.
HP
A
A
kA
kA
Weight
approx.
kg
5
Size S002)
0.16
0.2
0.25
0.32
-----
-----
0.11 ... 0.16
0.14 ... 0.2
0.18 ... 0.25
0.22 ... 0.32
2.1
2.6
3.3
4.2
65
65
65
65
30
30
30
30
3RV21 11-0AA10
3RV21 11-0BA10
3RV21 11-0CA10
3RV21 11-0DA10
0.320
0.320
0.320
0.320
0.4
0.5
0.63
0.8
-----
-----
0.28 ... 0.4
0.35 ... 0.5
0.45 ... 0.63
0.55 ... 0.8
5.2
6.5
8.2
10
65
65
65
65
30
30
30
30
3RV21 11-0EA10
3RV21 11-0FA10
3RV21 11-0GA10
3RV21 11-0HA10
0.320
0.320
0.320
0.320
1
1.25
1.6
2
-1/2
3/4
3/4
1/2
1/2
3/4
1
0.7 ... 1
0.9 ... 1.25
1.1 ... 1.6
1.4 ... 2
13
16
21
26
65
65
65
65
30
30
30
30
3RV21 11-0JA10
3RV21 11-0KA10
3RV21 11-1AA10
3RV21 11-1BA10
0.380
0.380
0.380
0.380
2.5
3.2
4
5
1
1.5
2
3
1.5
2
3
3
1.8 ... 2.5
2.2 ... 3.2
2.8 ... 4
3.5 ... 5
33
42
52
65
65
65
65
65
30
30
30
30
3RV21 11-1CA10
3RV21 11-1DA10
3RV21 11-1EA10
3RV21 11-1FA10
0.380
0.390
0.380
0.390
6.3
8
10
12.5
16
3
5
5
7.5
10
3
5
7.5
10
10
4.5 ... 6.3
5.5 ... 8
7 ... 10
9 ... 12.5
11 ... 16
82
104
130
163
208
65
65
65
65
65
30
30
30
30
--
3RV21 11-1GA10
3RV21 11-1HA10
3RV21 11-1JA10
3RV21 11-1KA10
3RV21 11-4AA10
0.390
0.390
0.390
0.390
0.400
16
20
22
10
10
15
10
10
15
11 ... 16
14 ... 20
17 ... 22
208
260
286
65
65
65
----
3RV21 21-4AA10
3RV21 21-4BA10
3RV21 21-4CA10
0.400
0.400
0.400
25
28
32
15
20
20
15
20
20
20 ... 25
23 ... 28
27 ... 32
325
364
400
65
50
50
----
3RV21 21-4DA10
3RV21 21-4NA10
3RV21 21-4EA10
0.400
0.410
0.410
Size S02)
1)
Guide value for 4-pole standard motors at AC 60 Hz 600 V. Select MSP by
motor full load amps. Horsepower ratings for reference only.
2)
Accessories for mounting on the right and 3RV29 15 three-phase busbars
cannot be used.
Auxiliary switches can be ordered separately
(see "Mountable accessories").
5/14
SIRIUS Innovations Supplement 2012
SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A
Circuit Breakers
For starter combinations
for export applications
■ Selection and ordering data
Without auxiliary switches
These Circuit Breakers are designed for export only
applications.
3RV23 11-0JC20
3RV23 11-4AC10
Suitable
for
induction
motors1)
with P
Thermal
overload
releases2)
Instantaneous overcurrent
releases
In
I
A
kW
v
Rated
current
Short-circuit
breaking
capacity at
400 V AC
Screw terminals
Icu
Order No.
A
A
kA
3RV23 21-4AC20
3RV23 21-4AC10
Weight
approx.
Spring-type
terminals
Weight
approx.
Order No.
kg
kg
0.16
0.2
0.25
0.32
0.04
0.06
0.06
0.09
Without
Without
Without
Without
2.1
2.6
3.3
4.2
100
100
100
100
3RV23 11-0AC10
3RV23 11-0BC10
3RV23 11-0CC10
3RV23 11-0DC10
0.260
0.260
0.260
0.260
3RV23 11-0AC20
3RV23 11-0BC20
3RV23 11-0CC20
3RV23 11-0DC20
0.270
0.280
0.280
0.280
0.4
0.5
0.63
0.8
0.09
0.12
0.18
0.18
Without
Without
Without
Without
5.2
6.5
8.2
10
100
100
100
100
3RV23 11-0EC10
3RV23 11-0FC10
3RV23 11-0GC10
3RV23 11-0HC10
0.260
0.260
0.260
0.260
3RV23 11-0EC20
3RV23 11-0FC20
3RV23 11-0GC20
3RV23 11-0HC20
0.290
0.290
0.280
0.280
1
1.25
1.6
2
0.25
0.37
0.55
0.75
Without
Without
Without
Without
13
16
21
26
100
100
100
100
3RV23 11-0JC10
3RV23 11-0KC10
3RV23 11-1AC10
3RV23 11-1BC10
0.320
0.320
0.320
0.320
3RV23 11-0JC20
3RV23 11-0KC20
3RV23 11-1AC20
3RV23 11-1BC20
0.340
0.350
0.350
0.350
2.5
3.2
4
5
0.75
1.1
1.5
1.5
Without
Without
Without
Without
33
42
52
65
100
100
100
100
3RV23 11-1CC10
3RV23 11-1DC10
3RV23 11-1EC10
3RV23 11-1FC10
0.320
0.320
0.320
0.320
3RV23 11-1CC20
3RV23 11-1DC20
3RV23 11-1EC20
3RV23 11-1FC20
0.350
0.350
0.350
0.350
6.3
8
10
12.5
16
2.2
3
4
5.5
7.5
Without
Without
Without
Without
Without
82
104
130
163
208
100
100
100
100
55
3RV23 11-1GC10
3RV23 11-1HC10
3RV23 11-1JC10
3RV23 11-1KC10
3RV23 11-4AC10
0.330
0.320
0.330
0.320
0.330
3RV23 11-1GC20
3RV23 11-1HC20
3RV23 11-1JC20
3RV23 11-1KC20
3RV23 11-4AC20
0.350
0.350
0.360
0.350
0.360
16
20
22
25
7.5
7.5
11
11
Without
Without
Without
Without
208
260
286
325
55
55
55
55
3RV23 21-4AC10
3RV23 21-4BC10
3RV23 21-4CC10
3RV23 21-4DC10
0.340
0.330
0.330
0.340
3RV23 21-4AC20
3RV23 21-4BC20
3RV23 21-4CC20
3RV23 21-4DC20
0.390
0.390
0.390
0.390
28
32
36
40
15
15
18.5
18.5
Without
Without
Without
Without
364
400
432
480
55
55
20
20
3RV23 21-4NC10
3RV23 21-4EC10
3RV23 21-4PC10
3RV23 21-4FC10
0.350
0.350
0.001
0.001
3RV23 21-4NC20
3RV23 21-4EC20
---
0.400
0.400
Size S0
1)
Guide value for 4-pole standard motors at AC 50 Hz 400 V. Select MSP by
motor full load amps. kW ratings for reference only.
2)
For overload protection of the motors, appropriate overload relays must be
used.
Auxiliary switches can be ordered separately
(see "Mountable accessories").
SIRIUS Innovations Supplement 2012
5/15
5
Size S00
SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A
Motor Starter Protectors
For transformer protection
■ Selection and ordering data
CLASS 10, without auxiliary switches
Motor starter protectors for the protection of transformers with high inrush current
3RV24 11-0AA10
Setting range
Thermal
overload
releases
Instantaneous
overcurrent
releases
In
A
I
Short-circuit
breaking
capacity at
480 V AC
v
Rated current
3RV24 11-0AA20
3RV24 21-4AA10
Short-circuit
breaking
capacity at
600 V AC
Screw terminals
Icu
Order No.
3RV24 21-4AA20
Weight
approx.
Spring-type
terminals
Weight
approx.
Order No.
A
A
kA
kA
kg
kg
0.16
0.2
0.25
0.32
0.11 ... 0.16
0.14 ... 0.2
0.18 ... 0.25
0.22 ... 0.32
3.3
4.2
5.2
6.5
65
65
65
65
30
30
30
30
3RV24 11-0AA10
3RV24 11-0BA10
3RV24 11-0CA10
3RV24 11-0DA10
0.260
0.260
0.260
0.260
3RV24 11-0AA20
3RV24 11-0BA20
3RV24 11-0CA20
3RV24 11-0DA20
0.290
0.290
0.290
0.290
0.4
0.5
0.63
0.8
0.28 ... 0.4
0.35 ... 0.5
0.45 ... 0.63
0.55 ... 0.8
8.2
10
13
16
65
65
65
65
30
30
30
30
3RV24 11-0EA10
3RV24 11-0FA10
3RV24 11-0GA10
3RV24 11-0HA10
0.260
0.260
0.260
0.320
3RV24 11-0EA20
3RV24 11-0FA20
3RV24 11-0GA20
3RV24 11-0HA20
0.290
0.290
0.290
0.350
1
1.25
1.6
2
0.7 ... 1
0.9 ... 1.25
1.1 ... 1.6
1.4 ... 2
21
26
33
42
65
65
65
65
30
30
30
30
3RV24 11-0JA10
3RV24 11-0KA10
3RV24 11-1AA10
3RV24 11-1BA10
0.320
0.320
0.320
0.320
3RV24 11-0JA20
3RV24 11-0KA20
3RV24 11-1AA20
3RV24 11-1BA20
0.350
0.350
0.350
0.350
2.5
3.2
4
5
1.8 ... 2.5
2.2 ... 3.2
2.8 ... 4
3.5 ... 5
52
65
82
104
65
65
65
65
30
30
30
30
3RV24 11-1CA10
3RV24 11-1DA10
3RV24 11-1EA10
3RV24 11-1FA10
0.320
0.330
0.330
0.330
3RV24 11-1CA20
3RV24 11-1DA20
3RV24 11-1EA20
3RV24 11-1FA20
0.350
0.360
0.350
0.360
6.3
8
10
12.5
16
4.5 ... 6.3
5.5 ... 8
7 ... 10
9 ... 12.5
11 ... 16
130
163
208
260
286
65
65
65
65
65
30
30
30
30
--
3RV24 11-1GA10
3RV24 11-1HA10
3RV24 11-1JA10
3RV24 11-1KA10
3RV24 11-4AA10
0.330
0.320
0.330
0.330
0.330
3RV24 11-1GA20
3RV24 11-1HA20
3RV24 11-1JA20
3RV24 11-1KA20
3RV24 11-4AA20
0.360
0.350
0.360
0.360
0.360
11 ... 16
14 ... 20
17 ... 22
20 ... 25
286
325
364
400
65
65
65
65
-----
3RV24 21-4AA10
3RV24 21-4BA10
3RV24 21-4CA10
3RV24 21-4DA10
0.340
0.320
0.350
0.350
3RV24 21-4AA20
3RV24 21-4BA20
3RV24 21-4CA20
3RV24 21-4DA20
0.390
0.380
0.400
0.410
5
Size S00
Size S0
16
20
22
25
Auxiliary switches can be ordered separately
(see "Mountable accessories").
5/16
SIRIUS Innovations Supplement 2012
SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A
For system protection
according to UL 489/CSA C22.2 No. 5-02
■ Selection and ordering data
Without auxiliary switches
Circuit breakers for system protection of motor3) and non-motor loads according to UL/CSA
3RV27 11-0AD10
Thermal overload releases
(non-adjustable)
Instantaneous
overcurrent release
In1)
A
I
Short-circuit
breaking capacity
at 480 Y/347 V AC2)
v
Rated
current1)
Short-circuit
breaking capacity
at 600 Y/347 V AC2)
Screw terminals
Ibc
Order No.
Weight
approx.
A
A
kA
kA
kg
0.16
0.2
0.25
0.32
0.16
0.2
0.25
0.32
2.1
2.6
3.3
4.2
65
65
65
65
10
10
10
10
3RV27 11-0AD10
3RV27 11-0BD10
3RV27 11-0CD10
3RV27 11-0DD10
0.390
0.390
0.390
0.390
0.4
0.5
0.63
0.8
0.4
0.5
0.63
0.8
5.2
6.5
8.2
10
65
65
65
65
10
10
10
10
3RV27 11-0ED10
3RV27 11-0FD10
3RV27 11-0GD10
3RV27 11-0HD10
0.390
0.390
0.390
0.390
1
1.25
1.6
2
1
1.25
1.6
2
13
16
21
26
65
65
65
65
10
10
10
10
3RV27 11-0JD10
3RV27 11-0KD10
3RV27 11-1AD10
3RV27 11-1BD10
0.450
0.450
0.460
0.460
2.5
3.2
4
5
2.5
3.2
4
5
33
42
52
65
65
65
65
65
10
10
---
3RV27 11-1CD10
3RV27 11-1DD10
3RV27 11-1ED10
3RV27 11-1FD10
0.460
0.460
0.450
0.460
6.3
8
10
12.5
15
6.3
8
10
12.5
15
82
104
130
163
208
65
65
65
65
65
------
3RV27 11-1GD10
3RV27 11-1HD10
3RV27 11-1JD10
3RV27 11-1KD10
3RV27 11-4AD10
0.460
0.460
0.460
0.460
0.470
1)
Rated value 100 % according to UL 489 and IEC 60947-2 ("100 % rated
breaker").
2)
Values for 600 Y/347 V AC can be found in the Technical Specifications
under "Permissible rated data of devices approved for North America
(UL/CSA)" --> "3RV27 and 3RV28 motor starter protectors as circuit
breakers", see note on Technical Information on pages 5/1 and 5/2.
3)
Requires use of supplemental overload protection for motor applications.
Lateral and transverse auxiliary switches can be ordered
separately (see "Mountable accessories").
SIRIUS Innovations Supplement 2012
5/17
5
Size S00
SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A
For transformer protection
according to UL 489/CSA C22.2 No. 5-02
■ Selection and ordering data
Without auxiliary switches
Circuit breakers for system and transformer protection according to UL/CSA,
specially designed for transformers with high inrush current
3RV28 11-0AD10
Thermal overload releases
(non-adjustable)
Instantaneous
overcurrent release
In1)
A
I
v
Rated
current1)
Short-circuit
breaking capacity
at 480 Y/277 V AC
Short-circuit
breaking capacity
@ 600 Y/347 V AC
Screw terminals
Weight
approx.
Order No.
Ibc
kg
A
A
kA
kA
0.16
0.2
0.25
0.32
0.16
0.2
0.25
0.32
3.3
4.2
5.2
6.5
65
65
65
65
10
10
10
10
3RV28 11-0AD10
3RV28 11-0BD10
3RV28 11-0CD10
3RV28 11-0DD10
0.390
0.390
0.390
0.390
0.4
0.5
0.63
0.8
0.4
0.5
0.63
0.8
8.2
10
13
16
65
65
65
65
10
10
10
10
3RV28 11-0ED10
3RV28 11-0FD10
3RV28 11-0GD10
3RV28 11-0HD10
0.390
0.390
0.400
0.450
1
1.25
1.6
2
1
1.25
1.6
2
21
26
33
42
65
65
65
65
10
10
10
10
3RV28 11-0JD10
3RV28 11-0KD10
3RV28 11-1AD10
3RV28 11-1BD10
0.450
0.460
0.460
0.460
2.5
3.2
4
5
2.5
3.2
4
5
52
65
82
104
65
65
65
65
10
----
3RV28 11-1CD10
3RV28 11-1DD10
3RV28 11-1ED10
3RV28 11-1FD10
0.460
0.460
0.460
0.460
6.3
8
10
12.5
15
6.3
8
10
12.5
15
130
163
208
260
286
65
65
65
65
65
------
3RV28 11-1GD10
3RV28 11-1HD10
3RV28 11-1JD10
3RV28 11-1KD10
3RV28 11-4AD10
0.460
0.460
0.460
0.460
0.470
5
Size S00
1)
Rated value 100 % according to UL 489 and IEC 60947-2 ("100 % rated
breaker").
Lateral and transverse auxiliary switches can be ordered
separately (see "Mountable accessories").
5/18
SIRIUS Innovations Supplement 2012
SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A
Accessories
Mountable accessories
SIRIUS Innovations Supplement 2012Overview
Mounting location and function
The 3RV2 motor starter protectors have three main contact
elements. In order to achieve maximum flexibility, auxiliary
switches, signaling switches, auxiliary releases, and isolator
modules can be supplied separately.
These components can be fitted on the motor starter protectors
without using tools.
Front side
An auxiliary switch block can be inserted transversely on the front. The
overall width of the motor starter protectors remains unchanged.
A maximum of 4 auxiliary contacts with
auxiliary switches can be attached per
motor starter protector.
Left-hand side
Notes:
Transverse auxiliary switch,
solid-state compatible transverse auxiliary switch
1 NO + 1 NC
or
2 NO
or
1 CO
Lateral auxiliary switches
(2 contacts)
A maximum of 4 auxiliary contacts with aux- 1 NO + 1 NC
iliary switches can be attached per motor or
2 NO
starter protector.
or
Auxiliary switches (2 contacts) and signal 2 NC
switches can be mounted separately or
Lateral auxiliary switches
together.
(4 contacts)
The signaling switch cannot be used for the
3RV27 and 3RV28 motor starter protectors/ 2 NO + 2 NC
circuit breakers.
Signaling switch
Tripping 1 NO + 1 NC
Short-circuit 1 NO + 1 NC
One of the three lateral auxiliary switches can be mounted on the left side
per motor starter protector. The contacts of the auxiliary switch close and
open together with the main contacts of the motor starter protector.
The overall width of the lateral auxiliary switch with 2 contacts is 9 mm.
One lateral auxiliary switch with four contacts can be mounted on the left
side per motor starter protector. The contacts of the auxiliary switch close
and open together with the main contacts of the motor starter protector.
The overall width of the lateral auxiliary switch with 4 contacts is 18 mm.
One signaling switch can be mounted on the left side of each motor starter
protector.
The signaling switch has two contact systems.
One contact system always signals tripping irrespective of whether this was
caused by a short-circuit, an overload or an auxiliary release. The other contact system only switches in the event of a short-circuit. There is no signaling
as a result of switching off with the handle.
In order to be able to switch on the motor starter protector again after a
short-circuit, the signaling switch must be reset manually after the error
cause has been eliminated.
The overall width of the signaling switch is 18 mm.
Right-hand side
Auxiliary releases
Notes:
Shunt releases
One auxiliary release can be mounted
per motor starter protector.
Accessories cannot be mounted
at the right-hand side of the 3RV21 motor
starter protectors
for motor protection with overload relay
function.
For remote-controlled tripping of the motor starter protector. The release coil
should only be energized for short periods (see schematics).
or
Undervoltage releases
Trips the motor starter protector when the voltage is interrupted and prevents the motor from being restarted accidentally when the voltage is
restored. Used for remote-controlled tripping of the motor starter protector.
Particularly suitable for EMERGENCY-STOP disconnection by way of the
corresponding EMERGENCY-STOP pushbutton according to
EN 60204-1 (VDE 0113).
or
Undervoltage releases with
leading auxiliary contacts 2 NO
Function and use as for the undervoltage release without leading auxiliary
contacts, but with the following additional function: the auxiliary contacts will
open in switch position OFF to deenergize the coil of the undervoltage
release, thus interrupting energy consumption. In the "tripped" position,
these auxiliary contacts are not guaranteed to open. The leading contacts
permit the motor starter protector to reclose.
The overall width of the auxiliary release is 18 mm.
Top
Isolator modules
Notes:
The isolator module cannot be used
for the 3RV27 and 3RV28 motor starter
protectors/circuit breakers.
The isolator module covers the terminal
screws of the transverse auxiliary switch. If
the isolator module is used, we therefore
recommend that either the lateral auxiliary
switches be fitted or that the isolator module not be mounted until the auxiliary switch
has been wired.
Isolator modules can be mounted to the upper terminal end of the motor
starter protectors.
The supply cable is connected to the motor starter protector through the isolator module.
The plug can only be unplugged when the motor starter protector is open
and isolates all 3 poles of the motor starter protector from the network. The
shock-protected isolation point is clearly visible and secured with a padlock
to prevent reinsertion of the plug.
For a complete overview of which accessories can be used
for the various motor starter protectors see page 5/2.
SIRIUS Innovations Supplement 2012
5/19
5
Note:
An overview graphic can be found on page 5/6.
SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A
Accessories
Mountable accessories
■ Selection and ordering data
Version
For
motor
starter
protectors
Screw terminals
Weight
approx.
Order No.
Size
Spring-type
terminals
Weight
approx.
Order No.
kg
kg
Auxiliary switches1)
Transverse auxiliary switches
for front mounting
1 CO
1 NO + 1 NC3)
2 NO
3RV29 01-1E
S00, S0
3RV29 01-1D
3RV29 01-1E
3RV29 01-1F
0.014
0.016
0.017
-3RV29 01-2E
3RV29 01-2F
0.016
0.017
Solid-state compatible
transverse auxiliary
switches
for mounting on the front,
for operation in
dusty atmosphere and
in solid-state circuits with
low operating currents
3RV29 01-2E
3RV29 01-1G
1 CO
S00, S0
3RV29 01-1G
0.015
--
Covers for transverse
auxiliary switch
S00, S0
3RV29 01-0H
0.001
--
S00, S0
3RV29 01-1A
3RV29 01-1B
3RV29 01-1C
3RV29 01-1J
0.036
0.037
0.037
0.066
3RV29 01-2A
3RV29 01-2B
3RV29 01-2C
--
0.035
0.035
0.035
S0
3RV29 21-1M
0.068
3RV29 21-2M
0.070
S0, S00
3RV29 28-1A
0.132
--
3RV29 01-0H
Lateral auxiliary switches
mountable on the left
5
1 NO + 1 NC3)
2 NO
2 NC
2 NO + 2 NC
3RV29 011A
3RV29 012A
Signaling switches2)
Signaling switches3)
One signaling switch can
be mounted
on the left per motor starter
protector.
Separate tripped and
short-circuit alarms,
1 NO + 1 NC each
3RV29 211M
3RV29 212M
Isolator modules2)
Isolator modules
Visible isolating distance
for isolating individual
motor starter protectors
from the network, lockable
in disconnected position.
3RV29 28-1A with
padlock
1)
One transverse auxiliary switch and one lateral auxiliary switch can be
attached per motor starter protector. The lateral auxiliary switch with 2 NO
+ 2 NC is used without a transverse auxiliary switch.
2)
This accessory cannot be used for the 3RV27 and 3RV28 motor starter
protectors.
3)
The 3RV29 auxiliary and signaling switches with 1 NO + 1 NC are also
available with ring lug terminal connection. The Order No. must be
changed in the 8th position to "4": e. g. 3RV29 01-4E.
5/20
SIRIUS Innovations Supplement 2012
Illustrations are approximate
SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A
Accessories
Mountable accessories
3RV29 02-1AV0
3RV29 02-2AV0
Rated control supply voltage Us
AC
50 Hz
AC
60 Hz
DC
For motor
starter
protectors
100 % ON
period1)
AC/DC
50/60 Hz,
DC
5 s ON
period2)
V
V
V
Size
AC
50/60 Hz
3RV29 22-1CP0
Screw terminals
3RV29 02-2DB0
Weight
approx.
Order No.
V
V
Spring-type
terminals
Weight
approx.
Order No.
kg
kg
Auxiliary releases3)
Undervoltage releases
--120
208
-----
-----
24
----
S00, S0
S00, S0
S00, S0
S00, S0
230
400
415
500
240
440
480
600
-----
-----
-----
S00, S0
S00, S0
S00, S0
S00, S0
----
----
S00, S0
S00, S0
S00, S0
20 ... 70
70 ... 190
190 ... 330
330 ... 500
500
------
S00, S0
S00, S0
S00, S0
S00, S0
S00, S0
4)
4)
3RV29 02-1AB4
3RV29 02-1AB0
3RV29 02-1AF0
3RV29 02-1AM1
0.121
0.118
0.117
0.111
-----
3RV29 02-1AP0
3RV29 02-1AV0
3RV29 02-1AV1
3RV29 02-1AS0
0.110
0.112
0.114
0.111
3RV29 02-2AP0
3RV29 02-2AV0
---
0.112
0.110
3RV29 22-1CP0
3RV29 22-1CV0
3RV29 22-1CV1
0.122
0.121
0.121
3RV29 22-2CP0
3RV29 22-2CV0
3RV29 22-2CV1
0.119
0.118
0.118
3RV29 02-1DB0
3RV29 02-1DF0
3RV29 02-1DP0
3RV29 02-1DV0
3RV29 02-1DS0
0.117
0.119
0.114
0.111
0.110
3RV29 02-2DB0
3RV29 02-2DF0
3RV29 02-2DP0
---
0.116
0.115
0.112
5
-24
110
--
Undervoltage releases with leading
auxiliary contacts 2 NO
230
400
415
240
440
480
----
4)
Shunt releases
------
------
20 ... 24
90 ... 110
210 ... 240
350 ... 415
500
4)
4)
1)
The voltage range is valid for 100 % (infinite) ON period.
The response voltage lies at 0.9 of the lower limit of the voltage range.
2)
The voltage range is valid for 5 s ON period at AC 50/60Hz and DC. The
response voltage lies at 0.85 of the lower limit of the voltage range.
3)
One auxiliary release can be mounted on the right per motor starter
protector (does not apply to 3RV21 motor starter protectors with overload
relay function).
4)
The 3RV29 auxiliary releases are also available with ring lug terminal
connection. The Order No. must be changed in the 8th position to "4":
e. g. 3RV29 02-4AP0.
Illustrations are approximate
SIRIUS Innovations Supplement 2012
5/21
SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A
Accessories
Busbar accessories
Insulated three-phase busbar systems
8US Fast Bus busbar adapters for 60 mm systems
Three-phase busbar systems provide an easy, time-saving and
clearly arranged means of feeding 3RV2 motor starter protectors
with screw terminals. They can be used for the different types of
motor starter protector up to 32 A. The 3RV19 15 three-phase
busbar systems are generally unsuitable for the 3RV21 motor
starter protectors for motor protection with overload relay function and for the 3RV27 and 3RV28 circuit breakers according to
UL 489 / CSA C22.2 No.5-02.
The motor starter protectors are mounted directly with the aid of
busbar adapters on busbar systems with 60 mm center-tocenter clearance in order to save space and to reduce infeed
times and costs.
The busbars are suitable for between 2 and 5 circuit breakers/
motor starter protectors. However, any kind of extension is possible by clamping the tags of an additional busbar (rotated
by 180°) underneath the terminals of the respective last motor
starter protector.
The motor starter protectors are snapped onto the adapter and
connected on the line side. This prepared unit is then plugged
directly onto the busbar system, and is thus connected both
mechanically and electrically at the same time.
A combination of motor starter protectors of sizes S00 and S0 is
possible. The motor starter protectors are supplied by
appropriate feeder terminals.
The busbar adapters for busbar systems with 60 mm center-tocenter clearance are suitable for copper busbars with a width of
12 to 30 mm. The busbars can be 5 mm or 10 mm thick.
Further busbar adapters for snap-mounting direct-on-line
starters and reversing starters as well as additional accessories
such as line terminals and outgoing terminals, flat copper profile,
etc., can be found in the Controls catalog, Chapter 5 "8US Fast
Bus Busbar Systems".
3RV29 25-5AB
5
3RV19 15-1CB
3RV19 15-6AB
Three-phase busbar system size S00/S0
The three-phase busbar systems are finger-safe. They are
designed for any short-circuit stress which can occur at the output side of connected motor starter protectors.
The three-phase busbar systems can also be used to construct
"Type E Starters" according to UL/CSA. Special feeder terminals
must be used for this purpose, however (see "Selection and
ordering data").
5/22
SIRIUS Innovations Supplement 2012
NSB0_02080
NSB0_02079
3RV29 15-5B
SIRIUS motor starters with busbar adapters snapped onto busbars
SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A
Accessories
Busbar accessories
■ Selection and ordering data
Modular
spacing
Number of motor starter
protectors that can be
connected
Without
lateral
accessories
Incl. lateral
auxiliary
switch
Incl.
auxiliary
release
mm
Rated
current
In at
690 V
For
motor
starter
protector
A
Size
Order No.
Weight
approx.
kg
Three-phase busbars1)2)
For feeding several motor starter protectors with
screw terminals, mounted side by side on standard mounting
rails, insulated, with touch protection.
3RV19 15-1AB
3RV19 15-1BB
3RV19 15-1CB
45
2
3
4
5
--
--
63
S00, S01)
S00, S01)
S00, S01)
S00, S01)
3RV19 15-1AB
3RV19 15-1BB
3RV19 15-1CB
3RV19 15-1DB
0.044
0.071
0.099
0.124
55
--
2
3
4
5
--
63
S00, S01)
S00, S01)
S00, S01)
S00, S01)
3RV19 15-2AB
3RV19 15-2BB
3RV19 15-2CB
3RV19 15-2DB
0.048
0.079
0.111
0.140
63
--
--
2
4
63
S00, S01)
S00, S01)
3RV19 15-3AB
3RV19 15-3CB
0.052
0.120
3RV19 15-1DB
2)
Not suitable for 3RV21 motor starter protectors for motor protection with
overload relay function and for 3RV27 and 3RV28 motor starter protectors/
circuit breakers according to UL 489 / CSA C22.2 No.5-02.
Conductor cross-section
Approved up to 32 A.
5
1)
Tightening
torque
For
motor
starter
protector
AWG
Nm
Size
10 ... 4
3 ... 4
S00, S0
3RV29 25-5AB
0.043
Input: 4,
Output:
2 ... 2.5
S00, S0
3RV29 15-5B
0.093
3 ... 4
S00, S0
3RV29 25-5EB
0.044
For
motor
starter
protector
Order No.
Solid or
stranded
Finely
stranded
with end
sleeve
AWG
cables,
solid or
stranded
mm²
mm²
Order No.
Weight
approx.
kg
Three-phase feeder terminals
Connection from top
2.5 ... 16
2.5 ... 16
Connection from below1)
3RV29 25-5AB
2.5 ... 16
2.5 ... 16
10 ... 4
3RV29 15-5B
Three-phase feeder terminals for constructing
"Type E Starters"
Connection from top
2.5 ... 16
2.5 ... 16
10 ... 4
3RV29 25-5EB
1)
This terminal is connected in place of a switch, please take the space
requirement into account.
Version
PU
(UNIT,
SET, M)
PS*
Size
Weight
approx.
kg
Covers for connection tags
Touch protection for empty
positions
S00, S0
3RV19 15-6AB
1
10 units
0.003
3RV19 15-6AB
* You can order this quantity or a multiple thereof.
Illustrations are approximate
SIRIUS Innovations Supplement 2012
5/23
SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A
Accessories
Busbar accessories
Busbar adapters
8US12 51-5DS10
8US12 51-5DT11
8US12 50-5AS10
For
motor starter protector
Rated
current
Connecting cable
Adapter
length
Adapter
width
Rated voltage
Size
A
AWG
mm
mm
V
8US12 50-5AT10
Order No.
PU
(UNIT,
SET, M)
PS*
Weight
approx.
kg
Busbar adapters for 60 mm systems
For flat copper profiles according to DIN 46433
Width: 12 mm and 30 mm
Thickness: 5 mm and 10 mm
also for T and double-T special profiles
• For motor starter protectors with screw terminals
Screw terminals
S00
16
12
200
45
690
8US12 51-5DS10
1
1 unit
0.183
S0
32
10
260
45
690
8US12 51-5NT10
1
1 unit
0.183
5
• For motor starter protectors with spring-type terminals
Spring-type
terminals
S00
16
12
260
45
690
8US12 51-5DT11
1
1 unit
0.183
S0
32
10
260
45
690
8US12 51-5NT11
1
1 unit
0.183
Device holders
For lateral attachment
to busbar adapters
--
--
200
45
--
8US12 50-5AS10
1
1 unit
0.183
--
--
260
45
--
8US12 50-5AT10
1
1 unit
0.183
Side modules
For widening of busbar adapters
--
--
200
9
--
8US19 98-2BJ10
1
1 unit
0.023
Spacers
Fixes the motor starter
onto the busbar
adapter
--
--
--
--
--
8US19 98-1BA10
1
10 units
0.183
Vibration and shock -kits
For high vibration and
shock loads
--
--
--
--
8US19 98-1CA10
1
1 unit
0.183
Accessories
For additional busbar adapters see the Controls catalog,
Chapter 5 "Fast Bus".
5/24
SIRIUS Innovations Supplement 2012
* You can order this quantity or a multiple thereof.
Illustrations are approximate
SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A
Accessories
3RV29 infeed system
Overview
The 3RV29 infeed system is a convenient means of energy
supply and distribution for a group of several motor starter
protectors or complete motor starters with a screw or springtype connection in sizes S00 and S0 (exception: this system
cannot be used for the 3RV21, 3RV27 and 3RV28 motor starter
protectors/circuit breakers).
The electrical connection between the three-phase busbars and
the motor starter protectors is implemented through plug-in
connectors. The complete system can be mounted on a TH 35
standard mounting rail to EN 60715 and can be expanded as
required up to a maximum current carrying capacity of 63 A.
The system is mounted extremely quickly and easily thanks to
the simple plug-in technique. Thanks to the lateral infeed, the
system also saves space in the control cabinet. The additional
overall height required for the infeed unit is only 30 mm. The
alternative infeed possibilities on each side offer a high degree
of flexibility for configuring the control cabinet: Infeed on lefthand or right-hand side as well as infeed on one side and outfeed on the other side to supply further loads are all possible. A
terminal block with spring-type connections in combination with
a standard mounting rail enables the integration of not only
SIRIUS motor starter protectors but also single-phase, 2-phase
and 3-phase components such as 5SY miniature circuit breakers
or SIRIUS relay components.
The system is based on a basic module complete with a lateral
incoming unit (three-phase busbar with infeed). This infeed with
spring-type terminals is mounted on the right or left depending
on the version and can be supplied with a maximum conductor
cross-section of 25 mm2 (with end sleeve). A basic module has
two sockets onto each of which a motor starter protector can be
snapped.
Expansion modules are available for extending the system
(three-phase busbars for system expansion). The individual
modules are connected through an expansion plug.
3b
5
3a
5
5
1
2
4
7
NSB0_02078
6
3-phase busbar with infeed
3-phase busbar for system expansion
3a Expansion plug
3b Extra-wide expansion plug
1
4
2
5
6
7
End cover
Plug-in connector
Contactor base
Terminal block
3RV29 infeed system
SIRIUS Innovations Supplement 2012
5/25
SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A
Accessories
3RV29 infeed system
$ Three-phase busbars with infeed
* Contactor base
A three-phase busbar with infeed unit is required for connecting
the energy supply. This module comprises one infeed module
and 2 sockets which each accept one motor starter protector. A
choice of two versions with infeed on the left or right is available.
The infeed is connected using spring-type terminals. The
spring-type terminals permit conductor cross-sections of up to
25 mm2 with end sleeves. An end cover is supplied with each
module.
Motor starters can be assembled in the system using the contactor base. The contactor bases are suitable for contactors sizes
S00 and S0 with spring-type and screw terminals and are simply
snapped onto the three-phase busbars. Direct-on-line starters
and reversing starters are possible. One contactor base is required for direct-on-line starters and two are required for reversing starters.
% Three-phase busbars for system expansion
The three-phase busbars for system expansion allow the system
to be expanded. There is a choice of modules with 2 or 3 sockets. The system can be expanded as required up to a maximum
current carrying capacity of 63 A. An expansion plug is supplied
with each module.
&a Expansion plug
The expansion plug is used for electrical connection of adjacent
three-phase busbars. The current carrying capacity of this plug
equals 63 A. One expansion plug is supplied with each threephase busbar for system expansion. Additional expansion plugs
are therefore only required as spare parts.
5
&b Extra-wide expansion plug
The wide expansion plug makes the electrical connection between two three-phase busbars, thus performing the same function as the 3RV29 17-5BA00 expansion plug; the electrical characteristics (e.g. a current carrying capacity of 63 A) are
identical.
The 3RV29 17-5E expansion plug is 10 mm wider than the
3RV29 17-5BA00 expansion plug, hence in the plugged state
there is a distance of 10 mm between the connected threephase busbars. This distance can be used to lay the auxiliary
current and control current wiring ("wiring duct"). The motor
starter protector and contactor can be wired from underneath,
which means that the complete cable duct above the system
can be omitted.
( End cover
The end cover is used to cover the three-phase busbar at the
open end of the system. This cover is therefore only required
once for each system. An end cover is supplied with each threephase busbar system with infeed. Further end covers are therefore only required as spare parts.
) Plug-in connector
The plug-in connector is used for the electrical connection between the three-phase busbar and the 3RV2 motor starter protector. These plug-in connectors are available in versions for
screw or spring-type terminals.
5/26
SIRIUS Innovations Supplement 2012
To assemble motor starters for reversing starters, the contactor
bases can be arranged alongside each other (90 mm overall
width). In this case the mechanical interlocking of the contactors
is possible. The contactor bases are also suitable for soft starters size S00 and S0 with screw connection.
The infeed system is designed for mounting on a 35 mm standard mounting rail with 7.5 mm overall depth. This standard
mounting rail gives the contactor base a stable mounting surface to sit on. If standard mounting rails with a depth of 15 mm
are used, the spacer connected to the bottom of the contactor
base must be knocked out and plugged into the mating piece
that is also on the underside. Then the contactor base also has
a stable mounting surface. When standard mounting rails with a
depth of 7.5 mm are used, the spacer has no function and can
be removed.
The link modules are used for direct start motor starters, in which
case the use of a contactor base is not absolutely necessary.
Motor starter protector and contactor assemblies can then be directly snapped onto the sockets of the three-phase busbars. For
starters of size S00 and S0, the corresponding 3RA19 21-1....,
3RA29 11-2...., 3RA29 21-1.... or 3RA29 21-2.... link modules
should generally be used.
+ Terminal block
The 3RV29 17-5D terminal block enables the integration of not
only SIRIUS motor starter protectors but also single-phase,
2-phase and 3-phase components. Using the terminal block the
3 phases can be fed out of the system; which means that singlephase loads can also be integrated in the system. The terminal
block is plugged into the slot of the expansion plug and thus enables outfeeding from the middle or end of the infeed system.
The terminal block can be rotated through 180° and be locked
to the support modules of the infeed system. The 3RV19 17-7B
45 mm standard mounting rail for screwing onto the support
plate is available in addition in order to be able to plug the single-phase, 2-phase and 3-phase components onto the infeed
system.
SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A
Accessories
3RV29 infeed system
■ Selection and ordering data
Type
Version
For 3RV20,
3RV23,
3RV24
motor
starter
protectors
Order No.
PU
(UNIT,
SET, M)
PS*
Size
Weight
approx.
kg
Three-phase busbars with infeed
3-phase
busbars with
infeed
incl. end cover
3RV29 17-6A
For 2 motor starter
protectors with
screw connection or
spring-type
terminals
• With infeed on the
left
S00, S0
3RV29 17-1A
1
1 unit
0.369
• With infeed on the
right
S00, S0
3RV29 17-1E
1
1 unit
0.369
• For 2 motor starter
protectors
S00, S0
3RV29 17-4A
1
1 unit
0.229
• For 3 motor starter
protectors
S00, S0
3RV29 17-4B
1
1 unit
0.328
3RV29 17-1A
Three-phase busbars for system expansion
For motor starter
protectors with
screw connection or
spring-type
terminals
5
Three-phase
busbars
incl. 3RV29 175BA00 expansion
plug
3RV29 17-4A
Plug-in connectors
Plug-in
connectors
to make contact
with the motor
starter protectors
• For spring-type
terminals
Spring-type
terminals
- Single-unit
packaging
S001)
S02)
3RV29 17-5AA00
3RV29 27-5AA00
1
1
1 unit
1 unit
0.046
0.059
- Multi-unit
packaging
S001)
S02)
3RV29 17-5A
3RV29 27-5A
1
1
10 units
10 units
0.046
0.059
3RV29 17-5AA00
• For screw
terminals
Screw terminals
- Single-unit
packaging
S001)
S02)
3RV29 17-5CA00
3RV19 27-5AA00
1
1
1 unit
1 unit
0.029
0.040
- Multi-unit
packaging
S001)
S02)
3RV29 17-5C
3RV19 27-5A
1
1
10 units
10 units
0.029
0.036
For
contactors
Order No.
PU
(UNIT,
SET, M)
PS*
Weight
approx.
3RV29 17-5CA00
Type
Version
Size
kg
Contactor bases
Contactor bases
for mounting
direct-on-line or
reversing starters
Single-unit
packaging
S00, S0
3RV29 27-7AA00
1
1 unit
0.050
3RV29 27-7AA00
1)
I > 14 A, note derating; see the system manual "SIRIUS Innovations",
Chapter "Motor Starter Protectors".
2)
I > 16 A, note derating; see the system manual "SIRIUS Innovations",
Chapter "Motor Starter Protectors".
* You can order this quantity or a multiple thereof.
Illustrations are approximate
SIRIUS Innovations Supplement 2012
5/27
SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A
Accessories
3RV29 infeed system
Type
Version
Order No.
PU
(UNIT,
SET, M)
PS*
Weight
approx.
kg
Terminal blocks
Single-unit packaging
3RV29 17-5D
1
1 unit
0.049
Single-unit packaging
3RV19 17-7B
1
1 unit
0.261
Extra-wide expansion
plugs as accessory
Single-unit packaging
3RV29 17-5E
1
1 unit
0.037
Expansion plugs1)
as spare part
Single-unit packaging
3RV29 17-5BA00
1
1 unit
0.026
End covers2)
as spare part
Multi-unit packaging
3RV29 17-6A
1
10 units
0.005
Terminal blocks
For integration of
single-phase, two-phase
and three-phase
components
3RV29 17-5D
45 mm standard mounting rails
45 mm standard
mounting rails
for mounting onto
bus bar adapters
3RV19 17-7B
Extra-wide expansion plugs
5
3RV29 17-5E
Expansion plugs
3RV29 17-5BA00
End covers
3RV29 17-6A
1)
The expansion plug is included in the scope of supply of the 3RV29 17-4
three-phase busbars for system expansion.
2)
The end cover is included in the scope of supply of the 3RV29 17-1 threephase busbars with infeed system.
5/28
SIRIUS Innovations Supplement 2012
* You can order this quantity or a multiple thereof.
Illustrations are approximate
SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A
Accessories
Rotary operating mechanisms
■ Overview
NSB01078
NSB01079a
Door-coupling rotary operating mechanisms
Motor starter protectors with a rotary operating mechanism can
be mounted in a control cabinet and operated externally by
means of a door-coupling rotary operating mechanism. When the
cabinet door with motor starter protector is closed, the operating
mechanism is coupled. When the motor starter protector closes,
the coupling is locked which prevents the door from being
opened unintentionally. This interlock can be disengaged by the
maintenance personnel. In the OPEN position, the rotary
operating mechanism can be secured against reclosing with up
to 3 padlocks. Inadvertent opening of the door is not possible in
this case either.
5
3RV29 26-2B door-coupling rotary operating mechanism for arduous
conditions
3RV29 26-0K door-coupling rotary operating mechanism
■ Selection and ordering data
Version
Color of
handle
Version of
extension
shaft
For motor
starter
protector
mm
Size
Order No.
Weight
approx.
kg
Door-coupling rotary operating mechanisms
The door-coupling rotary operating mechanisms consist of a knob, a coupling driver and a 130/330 mm long extension shaft
(6 mm x 6 mm).
The door-coupling rotary operating mechanisms are designed to degree of protection IP65. The door locking device prevents
accidental opening of the control cabinet door in the ON position of the motor starter protector. The OFF position can be locked
with up to 3 padlocks.
3RV29 26-0B
Black
Door-coupling rotary
operating
mechanisms
130
330
S00, S0
S00, S0
3RV29 26-0B
3RV29 26-0K
0.111
0.324
Red/
EMERYellow
GENCYSTOP doorcoupling
rotary
operating
mechanisms
130
330
S00, S0
S00, S0
3RV29 26-0C
3RV29 26-0L
0.110
0.316
Door-coupling rotary operating mechanisms for arduous conditions
The door-coupling rotary operating mechanisms consist of a knob, a coupling driver, an extension shaft of 300 mm in length
(8 mm x 8 mm), a spacer and two metal brackets, into which the motor starter protector is inserted.
The door-coupling rotary operating mechanisms are designed to degree of protection IP65. The door interlocking reliably prevents
opening of the control cabinet door in the ON position of the motor starter protector. The OFF position can be locked with up to
3 padlocks.
Laterally mountable auxiliary releases and two-pole auxiliary switches can be used.
The door-coupling rotary operating mechanisms thus meet the requirements for isolating functions according to IEC 60947-2.
3RV29 26-2B
Gray
Door-coupling rotary
operating
mechanisms
300
S00, S0
3RV29 26-2B
1.180
Red/
EMERYellow
GENCYSTOP doorcoupling
rotary
operating
mechanisms
300
S00, S0
3RV29 26-2C
1.188
Illustrations are approximate
SIRIUS Innovations Supplement 2012
5/29
SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A
Accessories
Mounting accessories
■ Overview
Accessories for "Self-Protected Combination Motor
Controllers (Type E)" according to UL 508
The 3RV20 motor starter protectors are approved according to
UL 508 as "Self-Protected Combination Motor Controllers
(Type E)".
This requires increased clearance and creepage distances
(1 inch and 2 inches respectively) at the input side of the device,
which are achieved by mounting terminal blocks. The
3RV29 28-1H terminal block is simply screwed onto the basic
unit.
Link modules
Starters can be easily assembled from single devices with the
help of the link modules. The following table shows the various
possible combinations for devices with screw connection or
spring-type terminals.
Combination
device
3RV2
motor
starter
protectors
Size
3RT2 contactors; 3RW30,
3RW40 soft
starters;
3RF34 solidstate contactors
Link modules
Screw
terminals
Spring-type
terminals
NSB0_01379b
Size
Link modules for connecting switching devices to 3RV2 motor starter
protectors1)
5
3RV29 28-1H terminal block
Another way to obtain the increased clearance and creepage
distances for Type E is to mount the 3RV29 28-1K phase barriers.
Special three-phase feeder terminals are required for constructing "Type E Starters" with an insulated three-phase busbar system
(see "Busbar Accessories").
Note:
According to CSA, the terminal blocks and the phase barriers
can be omitted when the device is used as a "Self-Protected
Combination Motor Controller" (Type E).
3RT2 contactors with AC or
DC coil
S00
S00
S0
S00
3RT2 contactors with AC
coil
S0
S0
S00
S0
3RT2 contactors with DC
coil
S0
S0
S00
S0
3RW30 soft
starters
S00
S00
S0
S00
S0
S0
S00
S0
S00/S0
S00
3RW30/3RW40
soft starters
3RF34 solidstate contactors
3RA19 211DA00
3RA29 112AA00
--
3RA29 211AA00
3RA29 212AA00
--
3RA29 211BA00
3RA29 212AA00
--
3RA29 211BA00
3RA29 112GA00
--
3RA29 211BA00
3RA29 212GA00
--
3RA29 211BA00
--
Hybrid link modules for connecting contactors with spring-type
terminals to 3RV2 motor starter protectors with screw connection1)
3RT2 contactors with AC or
DC coil
S00
S00
3RA29 112FA00
--
3RT2 contactors with AC or
DC coil
S0
S0
3RA29 212FA00
--
Note:
Link modules and hybrid link modules can be used up to max. 32 A.
1)
Link modules and hybrid link modules cannot be used for 3RV2. 21-4PA1.,
3RV2. 21-4FA1., 3RV27 and 3RV28 motor starter protectors.
■ Selection and ordering data
Accessories
Version
For
motor starter
protector
Order No.
PU
(UNIT,
SET, M)
PS*
Size
Weight
approx.
kg
Covers
Scale covers
Sealable,
for covering the set current scale
3RV20,
3RV21,
3RV24:
S00, S0
1
10 units
0.100
3RV29 28-4AA00
1
1 unit
0.010
3RV29 08-4AA10
1
1 unit
0.010
3RV29 08-0P
3RV29 08-0P
Covers for devices with
ring lug terminal connection
(ensure finger-safety)
• Main current level
3RV29 28-4AA00
• For transverse auxiliary switches
Ring lug terminal
connection
3RV20:
S00, S0
3RV29 08-4AA10
5/30
SIRIUS Innovations Supplement 2012
* You can order this quantity or a multiple thereof.
Illustrations are approximate
SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A
Accessories
Mounting accessories
Version
For
motor starter
protector
Order No.
PU
(UNIT,
SET, M)
PS*
Size
Weight
approx.
kg
Fixing material
Push-in lugs
For screwing the motor starter
protector onto mounting plates.
For each motor starter protector,
2 units are required.
S00, S0
3RV29 28-0B
1
10 units
0.100
1
1 unit
0.045
3RV29 28-0B
Tools for opening spring-type terminals by hand
Spring-type
terminals
Screwdrivers
for all SIRIUS devices with spring-type terminals
3RA29 08-1A
S00, S0
Length approx. 200 mm,
3.0 mm x 0.5 mm,
titanium gray/black,
partially insulated
3RA29 08-1A
Terminal blocks and phase barriers for
"Self-Protected Combination
Motor Controllers (Type E)" according to UL 508
Note:
UL 508 demands 1-inch clearance and 2-inch creepage distance at line side for "Combination Motor Controller Type E".
The following terminal blocks or phase barriers must be used in 3RV20 motor starter protectors.
The terminal blocks or phase barriers cannot be used in combination with the 3RV19 .5 three-phase busbars.
For construction with three-phase busbars, see "Busbar accessories".
3RV29 28-1K
Terminal blocks type E
For extended clearance and
creepage distances
(1 and 2 inch)
S00, S0
3RV29 28-1H
1
1 unit
0.065
Phase barriers
For extended clearance and
creepage distances
(1 and 2 inch)
S00, S0
3RV29 28-1K
1
1 unit
0.010
PU
(UNIT,
SET, M)
PS*
Weight
approx.
5
3RV29 28-1H
Link modules
Actuating voltage of
contactor
Size
3RT2
contactors
Order No.
3RV2 motor
starter
protectors
kg
Link modules for motor starter protector to contactor1)
For mechanical and electrical connection between
motor starter protector and contactor with screw
terminals
Screw terminals
Single-unit packaging
AC/DC
AC
DC
3RA29 21-1AA00
S00
S0
S0
S00/S0
S00/S0
S00/S0
3RA19 21-1DA00
3RA29 21-1AA00
3RA29 21-1BA00
1
1
1
1 unit
1 unit
1 unit
0.028
0.001
0.001
S00
S0
S0
S00/S0
S00/S0
S00/S0
3RA19 21-1D
3RA29 21-1A
3RA29 21-1B
1
1
1
10 units
10 units
10 units
0.021
0.001
0.001
Multi-unit packaging
AC/DC
AC
DC
For mechanical and electrical connection between
motor starter protector and contactor with springtype terminals
Spring-type
terminals
Single-unit packaging
AC/DC
AC2)
DC
S00
S0
S0
S00
S0
S0
3RA29 11-2AA00
3RA29 21-2AA00
3RA29 21-2AA00
1
1
1
1 unit
1 unit
1 unit
0.040
0.077
0.077
S00
S0
S0
S00
S0
S0
3RA29 11-2A
3RA29 21-2A
3RA29 21-2A
1
1
1
10 units
10 units
10 units
0.400
0.770
0.770
S0
S0
3RA29 11-1CA00
3RA29 11-1C
1
1
1 unit
5 units
0.001
0.001
Multi-unit packaging
3RA29 11-2AA00
AC/DC
AC2)
DC
Spacers2)
for compensating the height on AC contactors
Single-unit packaging
Multi-unit packaging
S0
S0
1)
The link modules for motor starter protector to contactor cannot be used
for the 3RV2. 21-4PA1., 3RV2. 21-4FA1., 3RV27 and 3RV28 motor starter
protectors.
2)
A spacer for height compensation on AC contactors size S0 is optionally
available.
* You can order this quantity or a multiple thereof.
Illustrations are approximate
Note:
Link modules can be used up to max. 32 A.
SIRIUS Innovations Supplement 2012
5/31
SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A
Accessories
Mounting accessories
Size
3RW30, 3RW40
soft starters;
3RF34
solid-state contactors
Order No.
PU
(UNIT,
SET, M)
3RV2
motor starter protectors
PS*
Weight
approx.
kg
Link modules for motor starter protector to soft starter1) and
motor starter protector to solid-state contactor
Connection between motor starter protector and soft
starter / solid-state contactor with screw terminals
Screw terminals
Single-unit packaging
S00
S0
S00/S0
S00/S0
3RA29 21-1BA00
3RA29 21-1BA00
1
1
1 unit
1 unit
0.001
0.001
S00/S0
S00/S0
3RA29 21-1B
3RA29 21-1B
1
1
10 units
10 units
0.001
0.001
Multi-unit packaging
3RA29 21-1BA00
S00
S0
Connection between motor starter protector and
soft starter with spring-type terminals
Spring-type
terminals
Single-unit packaging
S00
S0
S00
S0
3RA29 11-2GA00
3RA29 21-2GA00
1
1
1 unit
1 unit
0.038
0.072
S00
S0
3RA29 11-2G
3RA29 21-2G
1
1
10 units
10 units
0.380
0.720
PS*
Weight
approx.
Multi-unit packaging
3RA29 21-2GA00
5
1)
S00
S0
The link modules for motor starter protector to soft starter and for motor
starter protector to solid-state contactor cannot be used for the
3RV2. 21-4PA1., 3RV2. 21-4FA1., 3RV27 and 3RV28 motor starter
protectors.
Actuating voltage of
contactor
Note:
Link modules can be used up to max. 32 A.
Size
3RT2
contactors
Order No.
PU
(UNIT,
SET, M)
3RV2
motor
starter
protectors
kg
Hybrid link modules for motor starter protector to contactor1)
For mechanical and electrical connection
between motor starter protector with screw terminals
and contactor with spring-type terminals
Single-unit packaging
AC/DC
AC2)/DC
S00
S0
S00
S0
3RA29 11-2FA00
3RA29 21-2FA00
1
1
1 unit
1 unit
0.029
0.056
S00
S0
S00
S0
3RA29 11-2F
3RA29 21-2F
1
1
10 units
10 units
0.290
0.560
S0
S0
3RA29 11-1CA00
3RA29 11-1C
1
1
1 unit
5 units
0.001
0.001
3RA29 11-2FA00
Multi-unit packaging
AC/DC
AC2)/DC
Spacers2)
for compensating the height on AC contactors
Single-unit packaging
Multi-unit packaging
S0
S0
3RA29 21-2FA00
1)
The hybrid link modules for motor starter protector to contactor cannot be
used for the 3RV2. 21-4PA1., 3RV2. 21-4FA1., 3RV27 and 3RV28 motor
starter protectors.
2)
A spacer for height compensation on AC contactors size S0 is optionally
available.
5/32
SIRIUS Innovations Supplement 2012
Note:
Hybrid link modules can be used up to max. 32 A.
* You can order this quantity or a multiple thereof.
Illustrations are approximate
SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A
Accessories
Enclosures and front plates
Overview
Enclosures 1)
For stand-alone installation of 3RV20 to 3RV24 motor starter
protectors size S00 (In max = 16 A) and S0 (In max = 32 A), cast
aluminum enclosures for surface mounting and molded-plastic
enclosures for flush mounting are available in various
dimensions.
When installed in a molded-plastic enclosure, the motor starter
protectors have a rated operational voltage Ue of 500 V.
The enclosures for surface mounting have the degree of protection IP55; the enclosures for flush mounting also comply with the
degree of protection IP55 at the front (the flush-mounted section
complies with IP20).
All enclosures are equipped with N and PE terminals. There are
two knock-out cable entries for cable glands at the top and two
at the bottom; also on the rear corresponding cable entries are
scored. There is a knockout on the top of the enclosure for indicator lights that are available as accessories.
The narrow enclosure can accommodate a motor starter protector without accessories, with transverse auxiliary switch and with
lateral auxiliary switch. The installation of a motor starter protector with signalling switch is not intended.
With the motor starter protectors size S00 and S0, the moldedplastic enclosures are equipped with a rotary operating
mechanism.
The enclosures can be supplied with either a black rotary operating mechanism or with an EMERGENCY-STOP rotary operating mechanism with a red/yellow handle.
All rotary operating mechanisms can be locked in the OFF position with up to 3 padlocks.
Front plates
A holder for the motor starter protectors size S00 and S0, into
which the motor starter protectors can be snapped, is available
for the front plates.
NSB0_02081
Enclosures for surface mounting
NSB0_02083
NSB0_02082
Front plate (including holder) for sizes S00 and S0
Enclosures for flush mounting
1)
Not CSA, for export only
SIRIUS Innovations Supplement 2012
5/33
5
Motor starter protectors are frequently required to be actuated in
any enclosure. Front plates equipped with a rotary operating
mechanism for 3RV20 to 3RV24 motor starter protectors size
S00 and S0 are available for this purpose.
SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A
Accessories
Enclosures and front plates
■ Selection and ordering data
Version
Degree
of protection
Integrated
terminals
Width
For
3RV20
to
3RV24
motor
starter
protectors
mm
Size
Order No.
Weight
approx.
kg
Molded-plastic enclosures for surface mounting
3RV19 23-1FA00
IP55
With
rotary
operating
mechanism,
lockable in
0 position
N and
PE
With EMER- IP55
GENCYSTOP rotary
operating
mechanism,
lockable in
0 position
N and
PE
54
(for switch +
lateral auxiliary
switch)
S00, S0
3RV19 23-1CA00
0.332
72
(for switch +
lateral auxiliary
switch +
auxiliary release)
S00, S0
3RV19 23-1DA00
0.381
54
(for switch +
lateral auxiliary
switch)
S00, S0
3RV19 23-1FA00
0.329
72
(for switch +
lateral auxiliary
switch +
auxiliary release)
S00, S0
3RV19 23-1GA00
0.372
5
Cast aluminum enclosures for surface mounting
3RV19 23-1DA01
IP65
With
rotary operating mechanism,
lockable in
0 position
PE1)
72
(for switch +
lateral auxiliary
switch +
auxiliary release)
S00, S0
3RV19 23-1DA01
1.015
With EMER- IP65
GENCYSTOP rotary
operating
mechanism,
lockable in
0 position
PE1)
72
(for switch +
lateral auxiliary
switch +
auxiliary release)
S00, S0
3RV19 23-1GA01
1.008
Molded-plastic enclosure for flush mounting
3RV19 23-2DA00
1)
IP55
With
rotary oper- (front
ating mecha- side)
nism,
lockable in
0 position
N and
PE
72
(for switch +
lateral auxiliary
switch +
auxiliary release)
S00, S0
3RV19 23-2DA00
0.426
With EMER- IP55
(front
GENCYSTOP rotary side)
operating
mechanism,
lockable in
0 position
N and
PE
72
(for switch +
lateral auxiliary
switch +
auxiliary release)
S00, S0
3RV19 23-2GA00
0.417
If required, an additional N terminal can be mounted
(e.g. 8WA1 011-1BG11).
The enclosures listed on this page do not carry UL/CSA listings.
5/34
SIRIUS Innovations Supplement 2012
Illustrations are approximate
SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A
Accessories
Enclosures and front plates
Version
Degree
of protection
For
3RV20 to
3RV24
motor
starter
protectors
Order No.
Weight
approx.
Size
kg
Front plates
IP55
(front
side)
S00, S0
3RV19 23-4B
0.124
Molded-plastic front plates with
EMERGENCY-STOP rotary
operating mechanism,
red/yellow, lockable in 0 position
EMERGENCY-STOP actuation of
3RV2 motor starter protectors
in any enclosure.
IP55
(front
side)
S00, S0
3RV19 23-4E
0.124
Holders for front plates
Holder is mounted on front plate,
motor starter protector with and
without accessories is snapped in.
--
S00, S0
3RV19 23-4G
0.188
Rated control
supply voltage
Us
For
3RV20 to
3RV24
motor
starter
protectors
Order No.
V
Size
110 ... 120
220 ... 240
380 ... 415
480 ... 500
S00, S0
Version
Weight
approx.
5
3RV19 23-4B +
3RV19 23-4G
Molded-plastic front plates with
rotary operating mechanism,
lockable in 0 position
For actuation of 3RV2 motor starter
protectors in any enclosure.
kg
Indicator lights
Indicator lights
for all enclosures and front
plates
With glow lamp and colored
lenses red, green, yellow,
orange and clear
0.027
0.026
0.026
0.027
3RV19 03-5B
3RV19 03-5C
3RV19 03-5E
3RV19 03-5G
3RV19 03-5B
The front plates listed on this page do not carry UL/CSA listings.
Illustrations are approximate
SIRIUS Innovations Supplement 2012
5/35
Overload Relays
General data
■ Overview
Features
3RU21
3RB30/3RB31
Benefits
Sizes
S00, S0
S00, S0
• Are coordinated with the dimensions, connections and
technical characteristics of the other devices in the SIRIUS
modular system (contactors, soft starters, ...)
• Permit the mounting of slim and compact motor starters in
widths of 45 mm (S00 and S0)
• Simplify configuration
Seamless current range
0.11 ... 40 A
0.1 ... 40 A
• Allows easy and consistent configuration with one series of
overload relays (for small to large loads)
General data
5
Protection functions
Tripping in the event of overload
✓
✓
• Provides optimum inverse-time delayed protection of loads
against excessive temperature rises due to overload
Tripping in the event of phase
unbalance
✓
✓
• Provides optimum inverse-time delayed protection of loads
against excessive temperature rises due to phase
unbalance
• Minimizes heating of induction motors during phase failure
Tripping in the event of phase failure
✓
✓
Protection of single-phase loads
✓
--
Tripping in the event of a ground fault
--
✓
(only 3RB31)
by
internal ground-fault detection
(activatable)
• Enables the protection of single-phase loads
• Provides optimum protection of loads against highresistance short-circuits or ground faults due to moisture,
condensed water, damage to the insulation material, etc.
• Eliminates the need for additional special equipment.
• Saves space in the control cabinet
• Reduces wiring outlay and costs
Features
RESET function
Remote RESET function
✓
✓
✓
(by means of separate
module)
✓
(only 3RB31 with 24 V DC)
• Allows manual or automatic resetting of the relay
• Allows the remote resetting of the relay
TEST function for auxiliary contacts
✓
✓
• Allows easy checking of the function and wiring
TEST function for electronics
--
✓
• Allows checking of the electronics
Status display
✓
✓
• Displays the current operating state
Integrated auxiliary contacts
(1 NO + 1 NC)
✓
✓
• Allows the load to be switched off if necessary
• Can be used to output signals
✓ Available
-- Not available
5/36
SIRIUS Innovations Supplement 2012
Overload Relays
General data
Features
3RU21
Benefits
3RB30/3RB31
Design of motor starters
Short-circuit strength up to 100 kA
at 690 V
(in conjunction with the corresponding
fuses or the corresponding motor starter
protector)
✓
✓
• Provides optimum protection of the loads and operating
personnel in the event of short-circuits due to insulation faults
or faulty switching operations
Electrical and mechanical matching to
3RT2 contactors
✓
✓
• Simplifies configuration
Spring-type terminal connection
system for main circuit
✓
✓
Spring-type terminal connection
system for auxiliary circuits
✓
✓
• Enables fast connections
• Permits vibration-resistant connections
• Enables maintenance-free connections
Temperature compensation
✓
✓
• Allows the use of the relays at high temperatures without
derating
• Prevents premature tripping
• Allows compact installation of the control cabinet without
distance between the devices/motor starters
• Simplifies configuration
• Enables space to be saved in the control cabinet
High long-term stability
✓
✓
• Provides safe protection for the loads even after years of use
in severe operating conditions
Wide setting ranges
--
✓
(1:4)
• Reduce the number of variants
• Minimize the configuration outlay and costs
• Minimize storage overhead, storage costs, tied-up capital
Trip class CLASS 5
--
✓
(only 3RB31)
• Enables solutions for very fast starting motors requiring
special protection
Trip classes > CLASS 10
--
✓
• Enable heavy starting solutions
Low power loss
--
✓
• Reduces power consumption and energy costs (up 98 %
less power is used than for thermal overload relays)
• Minimizes temperature rises of the contactor and control
cabinet – in some cases this may eliminate the need for
controlgear cabinet cooling
• Reduces wiring outlay and costs
• Enables stand-alone installation as well as space-saving
direct mounting
• Enables fast connections
• Permits vibration-resistant connections
• Enables maintenance-free connections
5
Other features
• Direct mounting to contactor saves space, even for high
motor currents (i.e. no heat decoupling is required)
Internal power supply
--1)
Variable adjustment of the trip classes
(The required trip class can be adjusted
by means of a rotary switch depending
on the current start-up condition.)
--
✓ Available
-- Not available
✓
• Eliminates the need for configuration and connecting an
additional control circuit
✓
• Reduces the number of variants
(only 3RB31)
1)
• Minimizes the configuring outlay and costs
• Minimizes storage overhead, storage costs, and tied-up
capital
The SIRIUS 3RU21 thermal overload relays use a bimetal contactor and
therefore do not require a control supply voltage.
SIRIUS Innovations Supplement 2012
5/37
Overload Relays
General data
Overload relays
Type
Current
measurement
Type
Current range
Contactors (type, size, rating in HP)
A
3RT20 1
3RT20 2
S00
S0
3/5/7.5/10
7.5/10/15/20/25
3RU21 thermal overload relays1)
3RU21 1
Integrated
0.11 … 16
✓
--
3RU21 2
Integrated
1.8 … 40
--
✓
3RB301) solid-state overload relays
3RB30 1
Integrated
0.1 … 16
✓
--
3RB30 2
Integrated
0.1 … 40
--
✓
3RB211) solid-state overload relays
Integrated
0.1 … 16
✓
--
3RB31 2
Integrated
0.1 … 40
--
✓
5
3RB31 1
1)
✓ Available
-- Not available
Connection methods
Depending on the device version of the 3RU2 and 3RB3 overload relays, the terminals for screw, spring-type or ring lug terminal connection are configured for both the main and auxiliary
circuit.
Screw terminals
Spring-type terminals
Ring lug terminal connection
These terminals are indicated in the corresponding
tables by the symbols shown on orange
backgrounds.
5/38
SIRIUS Innovations Supplement 2012
"Technical Specifications" for use of the overload relays with trip class
t CLASS 20 can be found under "Short-circuit protection with fuses for
motor starters", see the note on Technical Information on page 5/1.
Overload Relays
SIRIUS 3RU2 Thermal Overload Relays
General data
■ Overview
The 3RU21 thermal overload relays up to 40 A have been
designed for current-dependent protection of loads with
normal starting (for "Function" see note on Technical Information
on page 5/1) against excessive temperature rises due to
overload or phase failure.
3
2
4
NSB0_02075a
5
6
1 Connection for mounting onto contactors:
Optimally adapted in electrical, mechanical and design terms to the
contactors. The overload relay can be connected directly to these
contactor using these pins. Stand-alone installation is possible as
an alternative (in conjunction with a terminal bracket for stand-alone
installation).
2 Selector switch for manual/automatic RESET and RESET button:
With this switch you can choose between manual and automatic
RESET. A device set to manual RESET can be reset locally by
pressing the RESET button. A remote RESET is possible using the
RESET modules (accessories), which are independent of size.
3 Switch position indicator and TEST function of the wiring:
Indicates a trip and enables the wiring test.
4 Motor current setting:
Setting the device to the rated motor current is easy with the large
rotary knob.
5 STOP button:
If the STOP button is pressed, the NC contact is opened. This
switches off the contactor downstream. The NC contact is closed
again when the button is released.
6 Supply terminals:
Depending on the device version, the terminals for screw,
spring-type or ring lug terminal connection are configured for the
main and auxiliary circuit.
An overload or phase failure results in an increase of the motor
current beyond the set rated motor current. Via heating elements, this current rise heats up the bimetal strips inside the
device which then bend and as a result trigger the auxiliary
contacts by means of a tripping mechanism. The auxiliary contacts then switch off the load by means of a contactor. The
switch-off time depends on the ratio between the tripping current
and set current Ie and is stored in the form of a long-term stable
tripping characteristic (for "Characteristic Curves" see the note
on Technical Information on page 5/1).
The "tripped" status is signaled by means of a switch position
indicator. Resetting takes place either manually or automatically
after a recovery time has elapsed (for "Function" see note on
Technical Information on page 5/1).
The devices are manufactured in accordance with environmental guidelines and contain environmentally friendly and reusable
materials.
They comply with all important worldwide standards and
approvals.
"Increased safety" type of protection EEx e according to
ATEX directive 94/9/EC
The 3RU21 thermal overload relays are suitable for the overload
protection of explosion-proof motors with "increased safety" type
of protection EEx e. The relays meet the requirements of
EN 60079-7 (Electrical apparatus for areas subject to explosion
hazards – Increased safety "e"); see Chapter 9 "Appendix"
--> "Standards and approvals" --> "Type overview of approved
devices for explosion-protected areas (ATEX Explosion
Protection)".
EC type test certificate for Category (2) G/D has been
submitted. More details on request.
A sealable transparent cover can be optionally mounted
(accessory). It secures the motor current setting against
adjustment.
3RU21 26-4FB00 thermal overload relays
■ Benefits
The most important features and benefits of the 3RU21 thermal
overload relays are listed in the overview table (see "General
data" on page 5/36).
SIRIUS Innovations Supplement 2012
5/39
5
1
Overload Relays
SIRIUS 3RU2 Thermal Overload Relays
General data
■ Application
Industries
Ambient conditions
The 3RU21 thermal overload relays are suitable for customers
from all industries who want to guarantee optimum currentdependent protection of their electrical loads (e. g. motors)
under normal starting conditions (CLASS 10).
The 3RU21 thermal overload relays have temperature compensation in accordance with IEC 60947-4-1 for the temperature
range of -40 to +60 °C. For temperatures from +60 to +80 °C the
upper set value of the setting range must be reduced by the
factor listed in the table below.
Application
Ambient
temperature
The 3RU21 thermal overload relays have been designed for the
protection of three-phase and single-phase AC and DC motors.
If single-phase AC or DC loads are to be protected by the 3RU21
thermal overload relays, all three bimetal strips must be heated.
For this purpose, all main current paths of the relay must be
connected in series.
Derating factor for the upper set value
°C
Current ranges
0.11 ... 20 A
17 ... 40 A
+60
1.0
1.0
+65
0.94
0.97
+70
0.87
0.94
+75
0.81
0.90
+80
0.73
0.86
■ Accessories
• Cable release for resetting devices which are difficult to
access for all sizes
• Electrical remote RESET module in three voltage variants for
all sizes
• Sealable cover for all sizes
• Terminal covers for devices with ring lug terminal connection
5
The following optional accessories are available for the 3RU21
thermal overload relays:
• Terminal bracket for stand-alone installation with screw or
spring-type terminals for each size
• Mechanical RESET for all sizes
■ More information
Order No. scheme
Digit of the Order No.
Thermal overload relays
1st 3rd
4th 5th 6th 7th
@@@
@
@
@
@
@
@
8th 9th 10th 11th
–
@
@
@
@
@
SIRIUS 2nd generation
2
@
Device series
Size, rated operational current and power
Setting range of the overload release
@
Connection method
@
Installation type
Example
3RU
2
Note:
The Order No. scheme is presented here merely for information
purposes and for better understanding of the logic behind the
order numbers.
For your orders, please use the order numbers quote in the
catalog under the Selection and ordering data section.
5/40
SIRIUS Innovations Supplement 2012
@
3RU
1
1
6
–
0
A
B
0
Overload Relays
SIRIUS 3RU2 Thermal Overload Relays
General data
3RU21 16
3RU21 26
S00
S0
45 x 89 x 79
45 x 102 x 80
45 x 97 x 95
45 x 114 x 97
W
D
Dimensions (W x H x D)
(overload relay with stand-alone installation
support)
• Screw terminals
• Spring-type terminals
H
Type
Size
mm
mm
General technical specifications
Overload and phase failure
Trips in the event of
Trip class acc. to IEC 60947-4-1
CLASS 10
Phase failure sensitivity
Yes
Overload warning
No
Reset and recovery
• Reset options after tripping
• Recovery time
- For automatic RESET
- For manual RESET
- For remote RESET
Manual, automatic and remote RESET1)
min
min
min
Depends on the strength of the tripping current and characteristic
Depends on the strength of the tripping current and characteristic
Depends on the strength of the tripping current and characteristic
Features
• Display of operating state on device
• TEST function
• RESET button
• STOP button
Yes, by means of TEST function/switch position indicator slide
Yes
Yes
Yes
Safe operation of motors with "increased safety" type of protection
EC type test certificate number acc. to directive 94/9/EC (ATEX)
On request
°C
°C
°C
-55 ... +80
-40 ... +70
Up to 60
%
%
100 (over +60 °C current reduction is not required)
87
5
Ambient temperature
• Storage/transport
• Operation
• Temperature compensation
• Permissible rated current at
- Temperature inside control cabinet 60 °C
- Temperature inside control cabinet 70 °C
Repeat terminals
• Coil repeat terminals
• Auxiliary contact repeat terminal
Yes
Yes
Degree of protection acc. to IEC 60529
IP20
Touch protection acc. to IEC 61140
Screw and spring-type terminals: Finger-safe
Ring lug terminal connection: Finger-safe only with optional terminal covers
Shock resistance with sine acc. to IEC 60068-2-27
Electromagnetic compatibility (EMC) – Interference immunity
• Conductor-related interference
- Burst acc. to IEC 61000-4-4 (corresponds to degree of severity 3)
- Surge acc.to IEC 61000-4-5 (corresponds to degree of severity 3)
• Electrostatic discharge acc. to IEC 61000-4-2
(corresponds to degree of severity 3)
• Field-related interference acc. to IEC 61000-4-3
(corresponds to degree of severity 3)
g/ms
15/112)
kV
kV
kV
EMC interference immunity is not relevant for thermal overload relays
EMC interference immunity is not relevant for thermal overload relays
EMC interference immunity is not relevant for thermal overload relays
V/m
EMC interference immunity is not relevant for thermal overload relays
EMC interference immunity is not relevant for thermal overload relays
Electromagnetic compatibility (EMC) – Emitted interference
Resistance to extreme climates – Air humidity
%
Mounting position
90
For "Dimensional drawings" see the note on Technical Information on page 5/1.
Dimensions
Installation altitude above sea level
Not required
Not required
m
Up to 2 000; above this, please enquire
The diagrams show the permissible mounting positions for mounting onto
contactors and stand-alone installation. For installation in the shaded area,
a setting correction of 10 % must be implemented.
Stand-alone installation:
0 °
4 5 °
4 5 °
0 °
1 e x 1 ,1
1 e x 1 ,1
9 0 °
9 0 °
1 3 5 °
1 3 5 °
N S B 0 1 3 6 4
1 e x 1 ,1
Contactor + overload relay:
0 °
1 3 5 °
2 2 ,5 °
1 3 5 °
0 °
2 2 ,5 °
N S B 0 1 3 6 3
1 e x 1 ,1
Type of mounting
1)
2)
Remote RESET in combination with the appropriate accessories.
Auxiliary contacts 95/96 and 97/98: 8 g/11 ms.
Mounting onto contactor/stand-alone installation with terminal bracket3)
3)
For screw and snap-on mounting on TH 35 standard mounting rail.
For the technical specifications of the terminal brackets see the note on
Technical Information on page 5/1.
SIRIUS Innovations Supplement 2012
5/41
Overload Relays
SIRIUS 3RU2 Thermal Overload Relays
General data
Type
3RU21 16
3RU21 26
Size
S00
S0
Width
45 mm
45 mm
Main circuit
Rated insulation voltage Ui
(pollution degree 3)
V
690
Rated impulse withstand voltage Uimp
kV
6
Rated operational voltage Ue
V
690
Type of current
Yes
• Direct current
Yes, frequency range up to 400 Hz
• Alternating current
A
0.11 ... 0.16
to
11 ... 16
1.8 ... 2.5
to
34 ... 40
W
3.9 ... 6.6
3.9 ... 6
A
Current setting
Power loss per unit (max.)
Short-circuit protection
• With fuse without contactor
See "Selection and ordering data"
• With fuse and contactor
See "Technical specifications" --> "Short-circuit protection with fuses/motor starter
protectors for motor starters", see note on Technical Information on page 5/1.
V
Protective separation between main
and auxiliary conducting path
acc. to IEC 60947-1
t440
Conductor cross-sections of main circuit
Connection type screw terminals
Screw terminals
M3, Pozidriv size 2
M4, Pozidriv size 2
Operating devices
mm
‡ 5 ... 6
‡ 5 ... 6
Prescribed tightening torque
Nm
0.8 ... 1.2
2 ... 2.5
• Solid
mm2
2 x (0.5 ... 1.5)1),
2 x (0.75 ... 2.5)1),
2 x (0.5 ... 4)1)
2 x (1 ... 2.5)1),
2 x (2.5 ... 10)1)
• Finely stranded with end sleeves
(DIN 46228 T1)
mm2
2 x (0.5 ... 1.5)1),
2 x (0.75 ... 2.5)1)
2 x (1 ... 2.5)1),
2 x (2.5 ... 6)1);
max. 1 x 10
• AWG cables, solid or stranded
AWG
2 x (20 ... 16)1),
2 x (18 ... 14)1),
2 x 12
2 x (16 ... 12)1),
2 x (14 ... 8)1)
Conductor cross-sections (min./max.),
1 or 2 conductors can be connected
Connection type spring-type terminals
Spring-type terminals
Operating devices
mm
3.0 x 0.5 and 3.5 x 0.5
Conductor cross-sections (min./max.)
• Solid
mm2
1 x (0.5 ... 4)
1 x (1 ... 10)
• Finely stranded without end sleeve
mm2
1 x (0.5 ... 2.5)
1 x (1 ... 6)
• Finely stranded with end sleeves
(DIN 46228 T1)
mm2
1 x (0.5 ... 2.5)
1 x (1 ... 6)
• AWG cables, solid or stranded
AWG
1 x (20 ... 12)
1 x (18 ... 8)
Ring lug terminal connection
Connection type ring lug terminals
M3, Pozidriv size 2
M4, Pozidriv size 2
Operating devices
mm
‡ 5 ... 6
‡ 5 ... 6
Prescribed tightening torque
Nm
0.8 ... 1.2
2 ... 2.5
mm
d2 = min. 3.2,
d3 = max. 7.5
d2 = min. 4.3,
d3 = max. 12.2
Terminal screw
Usable ring lug terminals
• DIN 46234 without insulation sleeve
d3
d2
• DIN 46225 without insulation sleeve
• DIN 46237 with insulation sleeve
• JIS C2805 Type R without insulation sleeve
• JIS C2805 Type RAV with insulation sleeve
• JIS C2805 Type RAP with insulation sleeve
1)
I2_12740
5
Terminal screw
If two different conductor cross-sections are connected to one clamping
point, both cross-sections must lie in the range specified. If identical crosssections are used, this restriction does not apply.
5/42
SIRIUS Innovations Supplement 2012
Overload Relays
SIRIUS 3RU2 Thermal Overload Relays
General data
Type
3RU21 16
3RU21 26
Size
S00
S0
Width
45 mm
45 mm
Auxiliary circuit
Number of NO contacts
1
Number of NC contacts
1
Auxiliary contacts – Assignment
1 NO for the signal "tripped",
1 NC for disconnecting the contactor
Rated insulation voltage Ui
(pollution degree 3)
V
690
Rated impulse withstand voltage Uimp
kV
6
• NC contact with alternating current AC-14/AC-15,
rated operational current Ie at Ue:
- 24 V
- 120 V
- 125 V
- 230 V
- 400 V
- 600 V
- 690 V
A
A
A
A
A
A
A
4
4
4
3
2
0.75
0.75
• NO contact with alternating current AC-14/AC-15,
rated operational current Ie at Ue:
- 24 V
- 120 V
- 125 V
- 230 V
- 400 V
- 600 V
- 690 V
A
A
A
A
A
A
A
3
3
3
2
1
0.75
0.75
• NC contact, NO contact with direct current DC-13,
rated operational current Ie at Ue:
- 24 V
- 60 V
- 110 V
- 125 V
- 220 V
A
A
A
A
A
1
On request
0.22
0.22
0.11
• Conventional thermal current Ith
A
6
5
Contact rating of the auxiliary contacts
Yes
• Contact reliability
(suitability for PLC control; 17 V, 5 mA)
Short-circuit protection
• With fuse
- Operational class gG
- Quick
A
A
6
10
• With miniature circuit breaker (C characteristic)
A
61)
Protective separation between main and auxiliary
conducting path
acc. to IEC 60947-1
V
t440
CSA, UL, UR rated data
Auxiliary circuit – Switching capacity
1)
B600, R300
Up to Ik d 0.5 kA; d 260 V.
SIRIUS Innovations Supplement 2012
5/43
Overload Relays
SIRIUS 3RU2 Thermal Overload Relays
General data
Type
3RU21 16
3RU21 26
Size
S00
S0
Width
45 mm
45 mm
Conductor cross-sections for auxiliary circuit
Connection type screw terminals
Screw terminals
M3, Pozidriv size 2
Terminal screw
Operating devices
mm
‡ 5 ... 6
Prescribed tightening torque
Nm
0.8 ... 1.2
• Solid
mm2
2 x (0.5 ... 1.5)1), 2 x (0.75 ... 2.5)1)
• Finely stranded with end sleeves (DIN 46228 T1)
mm2
2 x (0.5 ... 1.5)1), 2 x (0.75 ... 2.5)1)
• AWG cables, solid or stranded
AWG
2 x (20 ... 16)1), 2 x (18 ... 14)1)
Conductor cross-sections (min./max.),
1 or 2 conductors can be connected
Connection type spring-type terminals
Spring-type terminals
mm
3.0 x 0.5 and 3.5 x 0.5
• Solid
mm2
2 x (0.5 ... 2.5)
• Finely stranded without end sleeve
mm2
2 x (0.5 ... 1.5)
• Finely stranded with end sleeves (DIN 46228 T1)
mm2
2 x (0.5 ... 1.5)
• AWG cables, solid or stranded
AWG
2 x (20 ... 14)
Operating devices
Conductor cross-sections (min./max.)
Ring lug terminal connection
Connection type ring terminal end
M3, Pozidriv size 2
Operating devices
mm
‡ 5 ... 6
Prescribed tightening torque
Nm
0.8 ... 1.2
mm
d2 = min. 3.2,
d3 = max. 7.5
Usable ring lug terminals
• DIN 46234 without insulation sleeve
d3
d2
• DIN 46225 without insulation sleeve
• DIN 46237 with insulation sleeve
• JIS C2805 Type R without insulation sleeve
• JIS C2805 Type RAV with insulation sleeve
• JIS C2805 Type RAP with insulation sleeve
1)
I2_12740
5
Terminal screw
If two different conductor cross-sections are connected to one clamping
point, both cross-sections must lie in the range specified. If identical crosssections are used, this restriction does not apply.
5/44
SIRIUS Innovations Supplement 2012
Overload Relays
SIRIUS 3RU2 Thermal Overload Relays
3RU2 up to 40 A
for standard applications
■ Selection and ordering data
3RU21 thermal overload relays for mounting onto contactor1), CLASS 10
•
•
•
•
Features and technical specifications:
• Screw, spring-type or ring lug terminal connection2)
• Overload and phase failure protection
• Auxiliary contacts 1 NO + 1 NC
• Manual and automatic RESET
• Switch position indicators
3RU21 16-4AB0
3)
Size contactor
3RU21 16-4AC0
Current setting value of the
current-dependent
overload release
TEST function
STOP button
Sealable covers (optional accessory)
Terminal covers for devices with ring lug terminal
connection (optional accessory)
3RU21 26-4FB0
Screw terminals
3RU21 26-4AC0
Weight
approx.
Order No.
A
Spring-type
terminals
Weight
approx.
Order No.
kg
kg
S00
0.11 ... 0.16
0.14 ... 0.2
0.18 ... 0.25
0.22 ... 0.32
3RU21 16-0AB0
3RU21 16-0BB0
3RU21 16-0CB0
3RU21 16-0DB0
0.130
0.130
0.130
0.130
3RU21 16-0AC0
3RU21 16-0BC0
3RU21 16-0CC0
3RU21 16-0DC0
0.150
0.150
0.150
0.150
0.28 ... 0.4
0.35 ... 0.5
0.45 ... 0.63
0.55 ... 0.8
3RU21 16-0EB0
3RU21 16-0FB0
3RU21 16-0GB0
3RU21 16-0HB0
0.130
0.130
0.130
0.130
3RU21 16-0EC0
3RU21 16-0FC0
3RU21 16-0GC0
3RU21 16-0HC0
0.150
0.150
0.150
0.150
0.7 ... 1
0.9 ... 1.25
1.1 ... 1.6
1.4 ... 2
3RU21 16-0JB0
3RU21 16-0KB0
3RU21 16-1AB0
3RU21 16-1BB0
0.130
0.130
0.130
0.130
3RU21 16-0JC0
3RU21 16-0KC0
3RU21 16-1AC0
3RU21 16-1BC0
0.150
0.150
0.150
0.150
1.8 ... 2.5
2.2 ... 3.2
2.8 ... 4
3.5 ... 5
3RU21 16-1CB0
3RU21 16-1DB0
3RU21 16-1EB0
3RU21 16-1FB0
0.130
0.130
0.130
0.130
3RU21 16-1CC0
3RU21 16-1DC0
3RU21 16-1EC0
3RU21 16-1FC0
0.150
0.150
0.150
0.150
4.5 ... 6.3
5.5 ... 8
7 ... 10
9 ... 12.5
3RU21 16-1GB0
3RU21 16-1HB0
3RU21 16-1JB0
3RU21 16-1KB0
0.130
0.130
0.130
0.130
3RU21 16-1GC0
3RU21 16-1HC0
3RU21 16-1JC0
3RU21 16-1KC0
0.150
0.150
0.150
0.150
11 ... 16
3RU21 16-4AB0
0.130
3RU21 16-4AC0
0.150
1.8 ... 2.5
2.2 ... 3.2
2.8 ... 4
3.5 ... 5
3RU21 26-1CB0
3RU21 26-1DB0
3RU21 26-1EB0
3RU21 26-1FB0
0.160
0.160
0.160
0.160
3RU21 26-1CC0
3RU21 26-1DC0
3RU21 26-1EC0
3RU21 26-1FC0
0.220
0.220
0.220
0.220
4.5 ... 6.3
5.5 ... 8
7 ... 10
9 ... 12.5
3RU21 26-1GB0
3RU21 26-1HB0
3RU21 26-1JB0
3RU21 26-1KB0
0.160
0.160
0.160
0.160
3RU21 26-1GC0
3RU21 26-1HC0
3RU21 26-1JC0
3RU21 26-1KC0
0.220
0.220
0.220
0.220
11 ... 16
14 ... 20
17 ... 22
20 ... 25
3RU21 26-4AB0
3RU21 26-4BB0
3RU21 26-4CB0
3RU21 26-4DB0
0.160
0.160
0.160
0.160
3RU21 26-4AC0
3RU21 26-4BC0
3RU21 26-4CC0
3RU21 26-4DC0
0.220
0.220
0.220
0.220
23 ... 28
27 ... 32
30 ... 36
34 ... 40
3RU21 26-4NB0
3RU21 26-4EB0
3RU21 26-4PB0
3RU21 26-4FB0
0.160
0.160
0.160
0.160
3RU21 26-4NC0
3RU21 26-4EC0
3RU21 26-4PC0
3RU21 26-4FC0
0.220
0.220
0.220
0.220
Size S0
S0
1)
2)
3)
For matching terminal brackets see "Accessories" on page 5/47.
The 3RU21 overload relays are also available with ring lug terminal connection. The Order No. must be changed in the 10th position to "J":
e. g. 3RU21 16-0AJ0.
Observe maximum rated operational current of the devices.
Illustrations are approximate
SIRIUS Innovations Supplement 2012
5/45
5
Size S00
Overload Relays
SIRIUS 3RU2 Thermal Overload Relays
3RU2 up to 40 A
for standard applications
3RU21 thermal overload relays for stand-alone installation1), CLASS 10
•
•
•
•
Features and technical specifications:
• Screw or spring-type terminals
• Overload and phase failure protection
• Auxiliary contacts 1 NO + 1 NC
• Manual and automatic RESET
3RU21 16-4AC1
3RU21 16-4AB1
Size contactor2)
Current setting value of the
current-dependent
overload release
Switch position indicators
TEST function
STOP button
Sealable covers (optional accessory)
3RU21 26-4FB1
Screw terminals
3RU21 26-4FC1
Weight
approx.
Order No.
A
Spring-type
terminals
Weight
approx.
Order No.
kg
kg
Size S00
5
S00
0.11 ... 0.16
0.14 ... 0.2
0.18 ... 0.25
0.22 ... 0.32
3RU21 16-0AB1
3RU21 16-0BB1
3RU21 16-0CB1
3RU21 16-0DB1
0.170
0.170
0.170
0.170
3RU21 16-0AC1
3RU21 16-0BC1
3RU21 16-0CC1
3RU21 16-0DC1
0.190
0.190
0.190
0.190
0.28 ... 0.4
0.35 ... 0.5
0.45 ... 0.63
0.55 ... 0.8
3RU21 16-0EB1
3RU21 16-0FB1
3RU21 16-0GB1
3RU21 16-0HB1
0.170
0.170
0.170
0.170
3RU21 16-0EC1
3RU21 16-0FC1
3RU21 16-0GC1
3RU21 16-0HC1
0.190
0.190
0.190
0.190
0.7 ... 1
0.9 ... 1.25
1.1 ... 1.6
1.4 ... 2
3RU21 16-0JB1
3RU21 16-0KB1
3RU21 16-1AB1
3RU21 16-1BB1
0.170
0.170
0.170
0.170
3RU21 16-0JC1
3RU21 16-0KC1
3RU21 16-1AC1
3RU21 16-1BC1
0.190
0.190
0.190
0.190
1.8 ... 2.5
2.2 ... 3.2
2.8 ... 4
3.5 ... 5
3RU21 16-1CB1
3RU21 16-1DB1
3RU21 16-1EB1
3RU21 16-1FB1
0.170
0.170
0.170
0.170
3RU21 16-1CC1
3RU21 16-1DC1
3RU21 16-1EC1
3RU21 16-1FC1
0.190
0.190
0.190
0.190
4.5 ... 6.3
5.5 ... 8
7 ... 10
9 ... 12.5
3RU21 16-1GB1
3RU21 16-1HB1
3RU21 16-1JB1
3RU21 16-1KB1
0.170
0.170
0.170
0.170
3RU21 16-1GC1
3RU21 16-1HC1
3RU21 16-1JC1
3RU21 16-1KC1
0.190
0.190
0.190
0.190
11 ... 16
3RU21 16-4AB1
0.170
3RU21 16-4AC1
0.280
14 ... 20
17 ... 22
20 ... 25
3RU21 26-4BB1
3RU21 26-4CB1
3RU21 26-4DB1
0.200
0.200
0.200
3RU21 26-4BC1
3RU21 26-4CC1
3RU21 26-4DC1
0.280
0.280
0.280
23 ... 28
27 ... 32
30 ... 36
34 ... 40
3RU21 26-4NB1
3RU21 26-4EB1
3RU21 26-4PB1
3RU21 26-4FB1
0.200
0.200
0.200
0.200
3RU21 26-4NC1
3RU21 26-4EC1
3RU21 26-4PC1
3RU21 26-4FC1
0.280
0.280
0.280
0.280
Size S0
S0
1)
2)
Screw and snap-on mounting onto TH 35 standard mounting rail
Observe maximum rated operational current of the devices.
5/46
SIRIUS Innovations Supplement 2012
Illustrations are approximate
Overload Relays
SIRIUS 3RU2 Thermal Overload Relays
Accessories
■ Overview
Overload relays for standard applications
The following optional accessories are available for the 3RU21
thermal overload relays:
• Terminal bracket for stand-alone installation with screw or
spring-type terminals for each size
• Mechanical RESET for all sizes
• Cable release for resetting devices which are difficult to
access for all sizes
• Electrical remote RESET module in three voltage variants for
all sizes
• Sealable cover for all sizes
• Terminal covers for devices with ring lug terminal connection
■ Selection and ordering data
Version
Size
Order No.
Weight
approx.
kg
Terminal brackets for stand-alone installation1)
Screw terminals
Terminal brackets for overload relays
with screw terminals
For separate mounting of the overload
relays; screw and snap-on mounting onto
TH 35 standard mounting rail
S00
S0
3RU29 16-3AA01
3RU29 26-3AA01
0.040
0.050
5
3RU29 16-3AA01
3RU29 26-3AA01
Spring-type
terminals
Terminal brackets for overload relays
with spring-type terminals
For separate mounting of the overload
relays; screw and snap-on mounting onto
TH 35 standard mounting rail
S00
S0
3RU29 16-3AC01
3RU29 26-3AC01
0.040
0.060
3RU29 00-1A
0.038
3SB30 00-0EA11
0.020
3SX1 335
0.004
3RU29 16-3AC01
3RU29 26-3AC01
Mechanical RESET
Resetting plungers, holders and formers S00, S0
Pushbuttons with extended stroke
(12 mm), IP65, ‡ 22 mm
S00, S0
S00, S0
Extension plungers
For compensation of the distance between
the pushbutton and the unlatching button of
the relay
3RU29 00-1A
with pushbutton and
extension plunger
Cable releases with holder for RESET
For ‡ 6.5 mm hole in the control panel;
max. control panel thickness 8 mm
• Length 400 mm
S00, S0
3RU29 00-1B
0.063
• Length 600 mm
S00, S0
3RU29 00-1C
0.073
3RU29 00-1.
1)
The accessories are identical to those of the 3RB30/3RB31 solid-state
overload relays.
Illustrations are approximate
SIRIUS Innovations Supplement 2012
5/47
Overload Relays
SIRIUS 3RU2 Thermal Overload Relays
Accessories
Version
Size
Order No.
PU
(UNIT,
SET, M)
PS*
Weight
approx.
Modules for remote RESET, electrical
Operating range 0.85 ... 1.1 x Us,
power consumption AC 80 VA, DC 70 W,
ON period 0.2 ... 4 s,
switching frequency 60/h
3RU19 00-2A.71
• 24 ... 30 V AC/DC
S00, S0
3RU19 00-2AB71
0.066
• 110 ... 127 V AC/DC
S00, S0
3RU19 00-2AF71
0.067
• 220 ... 250 V AC/DC
S00, S0
3RU19 00-2AM71
0.066
For covering the setting knobs
S00, S0
3RV29 08-0P
Sealable covers
1 10 units
0.100
3RV29 08-0P
Terminal covers
Ring lug terminal
connection
Covers for devices with
ring lug terminal connection
(ensure finger-safety)
3RU29 16-3BJ21
3RU29 26-3BJ21
• Main current level
S00
- Cover between contactor
and overload relay
S0
for direct mounting of the overload relay
3RU29 16-3BJ21
3RU29 26-3BJ21
1 10 units
1 10 units
0.001
0.001
- Cover for overload relay
on load side
S00
S0
3RU29 16-3BJ20
3RV29 28-4AA00
1 10 units
1
1 unit
0.001
0.010
S00, S0
3RT29 16-4EA13
1 10 units
0.001
5
• Auxiliary current level
3RU29 16-3BJ20
3RV29 28-4AA00
3RT29 16-4EA13
General accessories
Version
Use
Order No.
PU
(UNIT,
SET, M)
PS*
Weight
approx.
kg
Tools for opening spring-type terminals
Screwdrivers
for all SIRIUS devices with spring-type terminals
3RA29 08-1A
Spring-type
terminals
Length approx. 200 mm,
3.0 mm x 0.5 mm,
titanium gray/black,
partially insulated
Main and
auxiliary circuit connection: 3RU2,
3RB3
3RA29 08-1A
Unit labeling plates1)
for SIRIUS devices
20 mm x 7 mm,
pastel turquoise
3RU2, 3RB3
3RT19 00-1SB20
1
1 unit
0.045
100 340 units
0.200
NSB0_01429b
Blank labels
3RT19 00-1SB20
1)
PC labeling system for individual inscription
of unit labeling plates available from:
murrplastik Systems, Inc.
www.murrplastik.com .
5/48
SIRIUS Innovations Supplement 2012
* You can order this quantity or a multiple thereof.
Illustrations are approximate
Overload Relays
SIRIUS 3RB3 Solid-State Overload Relays
General data
2
3
5
2
6
4
7
1 Connection for mounting onto contactors:
Optimally adapted in electrical, mechanical and design terms to the
contactors and soft starters. The overload relay can be connected
directly using these connection pins. Stand-alone installation is
possible as an alternative (in conjunction with a terminal bracket for
stand-alone installation).
2 Selector switch for manual/automatic RESET and RESET button:
With the slide switch you can choose between manual and
automatic RESET. A device set to manual RESET can be reset
locally by pressing the RESET button. On the 3RB31 an electrical
remote RESET is integrated.
3 Switch position indicator and TEST function of the wiring:
Indicates a trip and enables the wiring test.
4 Solid-state test (device test):
Enables a test of all important device components and
functions.
5 Motor current setting:
Setting the device to the rated motor current is easy with the
large rotary knob.
6 Trip class setting/internal ground-fault detection (only 3RB31):
Using the rotary switch you can set the required trip class and
activate the internal ground-fault detection dependent on the
start-up conditions.
7 Connecting terminals (removable joint block for auxiliary circuits):
Depending on the device version, the terminals for screw and
spring-type connection are configured for the main and auxiliary circuit.
A sealable transparent cover can be optionally mounted
(accessory). It secures the motor current setting against adjustment.
The 3RB30 and 3RB31 solid-state overload relays up to 40 A
with internal power supply have been designed for inverse-time
delayed protection of loads with normal and heavy starting
(for "Function" see note on Technical Information on page 5/1)
against excessive temperature rises due to overload, phase unbalance or phase failure. An overload, phase unbalance or
phase failure result in an increase of the motor current beyond
the set rated motor current. This current rise is detected by the
current transformers integrated into the devices and evaluated
by corresponding solid-state circuits which then output a pulse
to the auxiliary contacts. The auxiliary contacts then switch off
the load by means of a contactor. The break time depends on the
ratio between the tripping current and set current Ie and is stored
in the form of a long-term stable tripping characteristic (for
"Characteristic Curves" see the note on Technical Information on
page 5/1).
In addition to inverse-time delayed protection of loads against
excessive temperature rises due to overload, phase unbalance
and phase failure, the 3RB31 solid-state overload relays also allow internal ground-fault detection (not possible in conjunction
with contactor assemblies for wye-delta starting). This provides
protection of loads against high-resistance short-circuits due to
damage to the insulation material, moisture, condensed water
etc.
The "tripped" status is signaled by means of a switch position
indicator. Resetting takes place either manually or automatically
after a recovery time has elapsed (for "Function" see note on
Technical Information on page 5/1).
The devices are manufactured in accordance with environmental guidelines and contain environmentally friendly and reusable
materials. They comply with all important worldwide standards
and approvals.
"Increased safety" type of protection EEx e according to
ATEX directive 94/9/EC
The 3RB30/3RB31 solid-state overload relays are suitable for the
overload protection of explosion-proof motors with "increased
safety" type of protection EEx e. The relays meet the requirements of EN 60079-7 (Electrical apparatus for areas subject to
explosion hazards – Increased safety "e"); see Chapter 9
"Appendix" --> "Standards and approvals" --> "Type overview of
approved devices for explosion-protected areas (ATEX
Explosion Protection)".
3RB31 23-4VE00 solid-state overload relays
■ Benefits
The most important features and benefits of the 3RB30/3RB31
solid-state overload relays are listed in the overview table (see
"General data" on page 5/36).
SIRIUS Innovations Supplement 2012
5/49
5
1
NSB0_02077
■ Overview
Overload Relays
SIRIUS 3RB3 Solid-State Overload Relays
General data
■ Application
The 3RU21 thermal overload relay or the 3RB22/3RB23 solidstate overload relay can be used for single-phase AC loads. For
DC loads we recommend the 3RU21 thermal overload relay.
Industries
The 3RB30/3RB31 solid-state overload relays are suitable for
customers from all industries who want to guarantee optimum
inverse-time delayed protection of their electrical loads
(e.g. motors) under normal and heavy starting conditions
(CLASS 5 to CLASS 30), minimize project completion times,
inventories and power consumption, and optimize plant
availability and maintenance management.
Ambient conditions
The devices are insensitive to external influences such as
shocks, corrosive environments, ageing and temperature
fluctuation.
For the temperature range from –25 to +60 °C, the 3RB30/3RB31
solid-state overload relays compensate the temperature
according to IEC 60947-4-1.
Application
The 3RB30/3RB31 solid-state overload relays have been
designed for the protection of induction motors in sinusoidal
50/60 Hz voltage networks. The relays are not suitable for the
protection of single-phase AC or DC loads.
■ Accessories
The following optional accessories are available for the
3RB30/3RB31 solid-state overload relays:
• Terminal bracket for stand-alone installation with screw or
spring-type terminals for all sizes
• Mechanical RESET for all sizes
• Cable release for resetting devices which are difficult to
access for all sizes
• Sealable cover for all sizes
■ More information
5
Order No. scheme
Digit of the Order No.
Solid-state overload relays
1. - 3.
4.
5.
6.
7.
@@@
@
@
@
@
–
8.
9.
10. 11.
@
@
@
SIRIUS 3rd generation
3
@
Device series
@
Size, rated operational current and power
@
Version of the automatic RESET, electrical remote RESET
@
Trip class (CLASS)
@
Setting range of the overload release
@
Connection method
@
Installation type
3RB
Example
Note:
The Order No. scheme is presented here merely for information
purposes and for better understanding of the logic behind the
order numbers.
For your orders, please use the order numbers quote in the
catalog under the Selection and ordering data section.
5/50
SIRIUS Innovations Supplement 2012
@
3RB
3
0
1
6
–
1
R
B
0
Overload Relays
SIRIUS 3RB3 Solid-State Overload Relays
General data
Dimensions (W x H x D)
(overload relay with stand-alone installation
support)
• Screw terminals
• Spring-type terminals
W
3RB30 1.,
3RB31 1.
3RB30 2.,
3RB31 2.
S00
S0
45 x 89 x 80
45 x 102 x 80
45 x 97 x 94
45 x 116 x 95
D
Size
H
Type
mm
mm
General technical specifications
Overload, phase failure, and phase unbalance
+ ground fault (for 3RB31 only)
Trips in the event of
Trip class acc. to IEC 60947-4-1
CLASS 3RB30: 10, 20;
3RB31: 5, 10, 20 and 30 adjustable
Phase failure sensitivity
Yes
Overload warning
No
Reset and recovery
• Reset options after tripping
Manual, automatic and remote RESET (depending on the version)
• Recovery time
- For automatic RESET
min
Approx. 3
- For manual RESET
min
Immediately
- For remote RESET
min
Immediately
Features
Yes, by means of switch position indicator slide
Yes, test of electronics by pressing the TEST button /
Test of auxiliary contacts and wiring of control circuit
by actuating the switch position indicator slide /
Self-monitoring
• RESET button
Yes
• STOP button
No
5
• Display of operating state on device
• TEST function
Explosion protection – Safe operation of motors with
"increased safety" type of protection
EC type test certificate number acc. to directive 94/9/EC (ATEX)
PTB 09 ATEX 3001
II (2) GD
Ambient temperatures
• Storage/transport
°C
-40 ... +80
• Operation
°C
-25 ... +60
• Temperature compensation
°C
+60
- Temperature inside control cabinet 60 °C
%
100
- Temperature inside control cabinet 70 °C
%
On request
• Permissible rated current at
1001)
Repeat terminals
• Coil repeat terminals
Yes
Not required
• Auxiliary contact repeat terminal
Yes
Not required
Degree of protection acc. to IEC 60529
IP20
Touch protection acc. to IEC 61140
Finger-safe
g/ms
15/112)
- Burst acc. to IEC 61000-4-4
(corresponds to degree of severity 3)
kV
2 (power ports), 1 (signal ports)
- Surge acc. to IEC 61000-4-5
(corresponds to degree of severity 3)
kV
2 (line to earth), 1 (line to line)
• Electrostatic discharge acc. to IEC 61000-4-2
(corresponds to degree of severity 3)
kV
8 (air discharge), 6 (contact discharge)
• Field-related interference acc. to IEC 61000-4-3
(corresponds to degree of severity 3)
V/m
10
Shock resistance with sine acc. to IEC 60068-2-27
Electromagnetic compatibility (EMC) – Interference immunity
• Conductor-related interference
Degree of severity B according to EN 55011 (CISPR 11) and EN 55022 (CISPR 22)
Electromagnetic compatibility (EMC) – Emitted interference
Resistance to extreme climates – Air humidity
%
Installation altitude above sea level
95
For "Dimensional drawings" see the note on Technical Information on page 5/1.
Dimensions
m
Up to 2 000
Mounting position
Any
Type of mounting
Direct mounting/stand-alone installation with terminal bracket
1)
Permissible rated current for heavy starting
Size S0 at 10 to 40 A:
- CLASS 20, Ie max = 32 A,
- CLASS 30, Ie max = 25 A.
2)
Signaling contact 97/98 in position "tripped": 4/11 g/ms.
SIRIUS Innovations Supplement 2012
5/51
Overload Relays
SIRIUS 3RB3 Solid-State Overload Relays
General data
Type
3RB30 1.,
3RB31 1.
3RB30 2.,
3RB31 2.
Size
S00
S0
Width
45 mm
45 mm
Main circuit
Rated insulation voltage Ui
(pollution degree 3)
V
690
Rated impulse withstand voltage Uimp
kV
6
Rated operational voltage Ue
V
690
Type of current
• Direct current
No
Yes, 50/60 Hz r5 %
• Alternating current
Current setting
A
A
0.1 ... 0.4
to
4 ... 16
Power loss per unit (max.)
W
0.05 ... 0.2
0.1 ... 0.4
to
10 ... 40
Short-circuit protection
• With fuse without contactor
See "Selection and ordering data"
• With fuse and contactor
See "Technical specifications" --> "Short-circuit protection with fuses/motor starter
protectors for motor starters", see note on Technical Information on page 5/1.
Protective separation between main and auxiliary
conducting path acc. to IEC 60947-1 (pollution degree 2)
V
6901)
Conductor cross-sections of main circuit
Connection type screw terminals
Screw terminals
M3, Pozidriv size 2
M4, Pozidriv size 2
Operating devices
mm
‡ 5 ... 6
‡ 5 ... 6
Prescribed tightening torque
Nm
0.8 ... 1.2
2 ... 2.5
• Solid
mm2
2 x (0.5 ... 1.5)2),
2 x (0.75 ... 2.5)2),
2 x (0.5 ... 4)2)
2 x (1 ... 2.5)2),
2 x (2.5 ... 10)2)
• Finely stranded with end sleeves (DIN 46228 T1)
mm2
2 x (0.5 ... 1.5)2),
2 x (0.75 ... 2.5)2)
2 x (1 ... 2.5)2),
2 x (2.5 ... 6)2);
max. 1 x 10
• AWG cables, solid or stranded
AWG
2 x (20 ... 16)2),
2 x (18 ... 14)2),
2 x 12
2 x (16 ... 12)2),
2 x (14 ... 8)2)
5
Terminal screw
Conductor cross-sections (min./max.),
1 or 2 conductors can be connected
Connection type spring-type terminals
Spring-type terminals
mm
3.0 x 0.5 and 3.5 x 0.5
• Solid
mm2
1 x (0.5 ... 4)
1 x (1 ... 10)
• Finely stranded without end sleeve
mm2
1 x (0.5 ... 2.5)
1 x (1 ... 6)
• Finely stranded with end sleeves (DIN 46228 T1)
mm2
1 x (0.5 ... 2.5)
1 x (1 ... 6)
• AWG cables, solid or stranded
AWG
1 x (20 ... 12)
1 x (18 ... 8)
Operating devices
Conductor cross-sections (min./max.)
1)
For grounded networks, otherwise 600 V.
2) If two different conductor cross-sections are connected to one clamping
point, both cross-sections must lie in the range specified. If identical crosssections are used, this restriction does not apply.
5/52
SIRIUS Innovations Supplement 2012
Overload Relays
SIRIUS 3RB3 Solid-State Overload Relays
General data
Type
3RB30 1.,
3RB31 1.
3RB30 2.,
3RB31 2.
Size
S00
S0
Width
45 mm
45 mm
Auxiliary circuit
Number of NO contacts
1
Number of NC contacts
1
Auxiliary contacts – Assignment
1 NO for the signal "tripped",
1 NC for disconnecting the contactor
Rated insulation voltage Ui
(pollution degree 3)
V
300
Rated impulse withstand voltage Uimp
kV
4
• NC contact with alternating current AC-14/AC-15
Rated operational current Ie at Ue:
- 24 V
- 120 V
- 125 V
- 250 V
A
A
A
A
4
4
4
3
• NO contact with alternating current AC-14/AC-15:
Rated operational current Ie at Ue:
- 24 V
- 120 V
- 125 V
- 250 V
A
A
A
A
4
4
4
3
• NC, NO contact with direct current DC-13:
Rated operational current Ie at Ue:
- 24 V
- 60 V
- 110 V
- 125 V
- 250 V
A
A
A
A
A
2
0.55
0.3
0.3
0.11
• Conventional thermal current Ith
A
5
5
Auxiliary contacts – Contact rating
Yes
• Contact reliability
(suitability for PLC control; 17 V, 5 mA)
Short-circuit protection
• With fuse, gG operational class
A
6
Ground-fault protection (only 3RB31)
The information refers to sinusoidal residual currents at 50/60 Hz
• Tripping value I'
> 0.75 × Imotor
• Operating range I
• Response time ttrip (in steady-state condition)
Lower current setting value < Imotor < 3.5 × upper current setting value
s
<1
Integrated electrical remote RESET (only 3RB31)
Connecting terminals A3, A4
Protective separation between main and auxiliary
conducting path
acc. to IEC 60947-1
24 V DC, max. 200 mA for approx. 20 ms, then < 10 mA
V
300
CSA, UL, UR rated data
3RB30: B600, R300; 3RB31: B300, R300
Auxiliary circuit – Switching capacity
Conductor cross-sections for auxiliary circuit
Connection type screw terminals
Screw terminals
M3, Pozidriv size 2
Terminal screw
Operating devices
mm
‡ 5 ... 6
Prescribed tightening torque
Nm
0.8 ... 1.2
• Solid
mm2
1 × (0.5 ... 4), 2 × (0.5 ... 2.5)
• Finely stranded with end sleeve
mm2
1 × (0.5 ... 2.5), 2 × (0.5 ... 1.5)
• AWG cables, solid or stranded
AWG
2 × (20 ... 14)
Conductor cross-sections (min./max.),
1 or 2 conductors can be connected
Spring-type terminals
Connection type spring-type terminals
Operating devices
mm
3.0 x 0.5
Conductor cross-sections (min./max.),
1 or 2 conductors can be connected
• Solid
mm2
2 × (0.25 ... 1.5)
• Finely stranded without end sleeve
mm2
2 × (0.25 ... 1.5)
• Finely stranded with end sleeve
mm2
2 × (0.25 ... 1.5)
• AWG cables, solid or stranded
AWG
2 × (24 ... 16)
SIRIUS Innovations Supplement 2012
5/53
Overload Relays
SIRIUS 3RB3 Solid-State Overload Relays
3RB30, 3RB31 up to 40 A
for standard applications
■ Selection and ordering data
3RB30 solid-state overload relays for mounting onto contactor1), CLASS 10
Features and technical specifications:
• Screw and spring-type terminals
• Overload protection, phase failure protection and unbalance
protection
• Internal power supply
3RB30 16-1TB0
Size of contactor
3RB30 16-1TE0
2)
Set current value of the
inverse-time delayed
overload release
•
•
•
•
•
Auxiliary contacts 1 NO + 1 NC
Manual and automatic RESET
Switch position indicators
TEST function and self-monitoring
Sealable covers (optional accessory)
3RB30 26-1VB0
Screw terminals
3RB30 26-1VE0
Weight
approx.
Order No.
A
Spring-type
terminals
Weight
approx.
Order No.
kg
kg
Size S001)
5
S00
0.1 … 0.4
3RB30 16-1RB0
0.172
3RB30 16-1RE0
0.172
0.32 … 1.25
3RB30 16-1NB0
0.172
3RB30 16-1NE0
0.172
1…4
3RB30 16-1PB0
0.172
3RB30 16-1PE0
0.172
3 … 12
3RB30 16-1SB0
0.172
3RB30 16-1SE0
0.172
4 ... 16
3RB30 16-1TB0
0.172
3RB30 16-1TE0
0.172
Size S01)
S0
0.1 … 0.4
3RB30 26-1RB0
0.250
3RB30 26-1RE0
0.240
0.32 … 1.25
3RB30 26-1NB0
0.250
3RB30 26-1NE0
0.240
1…4
3RB30 26-1PB0
0.250
3RB30 26-1PE0
0.240
3 … 12
3RB30 26-1SB0
0.250
3RB30 26-1SE0
0.240
6 … 25
3RB30 26-1QB0
0.250
3RB30 26-1QE0
0.240
10 ... 40
3RB30 26-1VB0
0.250
3RB30 26-1VE0
0.240
1)
With the suitable terminal brackets (see "Accessories", page 5/57), these
overload relays can also be installed as stand-alone units.
2)
Observe maximum rated operational current of the devices.
5/54
SIRIUS Innovations Supplement 2012
Illustrations are approximate
Overload Relays
SIRIUS 3RB3 Solid-State Overload Relays
3RB30, 3RB31 up to 40 A
for standard applications
3RB30 solid-state overload relays for mounting onto contactor1), CLASS 20
Features and technical specifications:
• Screw and spring-type terminals
• Overload protection, phase failure protection and unbalance
protection
• Internal power supply
3RB30 16-2TB0
Size of contactor2)
3RB30 16-2TE0
Set current value of the
inverse-time delayed
overload release
•
•
•
•
•
Auxiliary contacts 1 NO + 1 NC
Manual and automatic RESET
Switch position indicators
TEST function and self-monitoring
Sealable covers (optional accessory)
3RB30 26-2VB0
Screw terminals
3RB30 26-2VE0
Weight
approx.
Order No.
A
Spring-type
terminals
Weight
approx.
Order No.
kg
kg
S00
0.1 … 0.4
3RB30 16-2RB0
0.172
3RB30 16-2RE0
0.172
0.32 … 1.25
3RB30 16-2NB0
0.172
3RB30 16-2NE0
0.172
1…4
3RB30 16-2PB0
0.172
3RB30 16-2PE0
0.172
3 … 12
3RB30 16-2SB0
0.172
3RB30 16-2SE0
0.172
4 ... 16
3RB30 16-2TB0
0.172
3RB30 16-2TE0
0.172
Size S01)
S0
0.1 … 0.4
3RB30 26-2RB0
0.200
3RB30 26-2RE0
0.250
0.32 … 1.25
3RB30 26-2NB0
0.200
3RB30 26-2NE0
0.250
1…4
3RB30 26-2PB0
0.200
3RB30 26-2PE0
0.250
3 … 12
3RB30 26-2SB0
0.200
3RB30 26-2SE0
0.250
6 … 25
3RB30 26-2QB0
0.200
3RB30 26-2QE0
0.250
10 ... 40
3RB30 26-2VB0
0.200
3RB30 26-2VE0
0.250
1)
With the suitable terminal brackets (see "Accessories", page 5/57), these
overload relays can also be installed as stand-alone units.
2)
Observe maximum rated operational current of the devices.
Illustrations are approximate
SIRIUS Innovations Supplement 2012
5/55
5
Size S001)
Overload Relays
SIRIUS 3RB3 Solid-State Overload Relays
3RB30, 3RB31 up to 40 A
for standard applications
3RB31 solid-state overload relays for mounting onto contactor1), CLASS 5, 10, 20 and 30 adjustable
Features and technical specifications:
• Screw and spring-type terminals
• Overload protection, phase failure protection and unbalance
protection
• Internal ground-fault detection (requires activation)
• Internal power supply
3RB31 13-4TB0
Size of contactor2)
3RB31 13-4TE0
Set current value of the
inverse-time delayed
overload release
•
•
•
•
•
•
Auxiliary contacts 1 NO + 1 NC
Manual and automatic RESET
Electrical remote RESET integrated
Switch position indicators
TEST function and self-monitoring
Sealable covers (optional accessory)
3RB31 23-4VB0
Screw terminals
3RB31 23-4VE0
Weight
approx.
Order No.
A
Spring-type
terminals
Weight
approx.
Order No.
kg
kg
Size S001)
5
S00
0.1 … 0.4
3RB31 13-4RB0
0.175
3RB31 13-4RE0
0.175
0.32 … 1.25
3RB31 13-4NB0
0.175
3RB31 13-4NE0
0.175
1…4
3RB31 13-4PB0
0.175
3RB31 13-4PE0
0.175
3 … 12
3RB31 13-4SB0
0.175
3RB31 13-4SE0
0.175
4 ... 16
3RB31 13-4TB0
0.175
3RB31 13-4TE0
0.175
Size S01)
S0
0.1 … 0.4
3RB31 23-4RB0
0.200
3RB31 23-4RE0
0.250
0.32 … 1.25
3RB31 23-4NB0
0.175
3RB31 23-4NE0
0.175
1…4
3RB31 23-4PB0
0.200
3RB31 23-4PE0
0.250
3 … 12
3RB31 23-4SB0
0.200
3RB31 23-4SE0
0.250
6 … 25
3RB31 23-4QB0
0.200
3RB31 23-4QE0
0.250
10 ... 40
3RB31 23-4VB0
0.200
3RB31 23-4VE0
0.250
1)
With the suitable terminal brackets (see "Accessories", page 5/57), these
overload relays can also be installed as stand-alone units.
2)
Observe maximum rated operational current of the devices.
5/56
SIRIUS Innovations Supplement 2012
Illustrations are approximate
Overload Relays
SIRIUS 3RB3 Solid-State Overload Relays
Accessories
■ Overview
Overload relays for standard applications
The following optional accessories are available for the
3RB30/3RB31 solid-state overload relays:
• Terminal bracket for stand-alone installation with screw or
spring-type terminals for all sizes
• Mechanical RESET for all sizes
• Cable release for resetting devices which are difficult to
access for all sizes
• Sealable cover for all sizes
■ Selection and ordering data
Version
Size
Order No.
Weight
approx.
kg
Terminal brackets for stand-alone installation1)
Terminal brackets for overload relays with
screw terminals
Screw terminals
S00
For separate mounting of the overload
relays; screw and snap-on mounting onto S0
TH 35 standard mounting rail
3RU29 16-3AA01
3RU29 26-3AA01
Terminal brackets for overload relays
with spring-type terminals
Spring-type
terminals
S00
For separate mounting of the overload
relays; screw and snap-on mounting onto S0
TH 35 standard mounting rail
3RU29 16-3AC01
3RU29 26-3AC01
0.040
0.060
0.040
0.050
3RU29 16-3AA01
5
3RU29 26-3AA01
3RU29 16-3AC01
3RU29 26-3AC01
Mechanical RESET
3RB39 80-0A
with pushbutton and
extension plunger
Resetting plungers, holders and
formers
S00, S0
3RB39 80-0A
0.038
Pushbuttons with extended stroke
(12 mm), IP65, ‡ 22 mm
S00, S0
3SB30 00-0EA11
0.020
Extension plungers
For compensation of the distance
between a pushbutton and the unlatching button of the relay
S00, S0
3SX1 335
0.004
Cable releases with holder for RESET
For ‡ 6.5 mm holes
in the control panel;
max. control panel thickness 8 mm
• Length 400 mm
S00, S0
3RB39 80-0B
0.063
• Length 600 mm
S00, S0
3RB39 80-0C
0.073
For covering the setting knobs
S00, S0
3RB39 84-0
0.001
3RB39 80-0.
Sealable covers
3RB39 84-0
1)
The accessories are identical to those of the 3RU21 thermal overload
relays.
Illustrations are approximate
SIRIUS Innovations Supplement 2012
5/57
Overload Relays
SIRIUS 3RB3 Solid-State Overload Relays
Accessories
General accessories
Version
Use
Order No.
PU
(UNIT,
SET, M)
PS*
Weight
approx.
kg
Tools for opening spring-type terminals
Screwdrivers
for all SIRIUS devices with spring-type terminals
3RA29 08-1A
Spring-type
terminals
Length approx. 200 mm,
3.0 mm x 0.5 mm,
titanium gray/black,
partially insulated
Main and
auxiliary
circuit
connection:
3RU2, 3RB3
3RA29 08-1A
Unit labeling plates1)
for SIRIUS devices
20 mm x 7 mm,
pastel turquoise
3RU2, 3RB3
3RT19 00-1SB20
1
1 unit
0.045
100 340 units
0.200
NSB0_01429b
Blank labels
3RT19 00-1SB20
PC labeling system for individual inscription
of unit labeling plates available from:
murrplastik Systems, Inc.
www.murrplastik.com .
5
1)
5/58
SIRIUS Innovations Supplement 2012