SAN FRANCISCO 187,000 SF / 24MVA DATA CENTER B e t t e r ...C o n n e c t e d HIGHLIGHTS First new Data Center in San Francisco in 14 years and is the only ‘purpose-built’ facility in the city Superior proximity to ‘High-Tech’ and ‘Bio-Tech’ All Data Halls benefit from outside air economization Lowest annualized PUE in the San Francisco Bay Area Best fiber connectivity in San Francisco Maximum flexibility in Design and MEP Engineering Most efficient and ‘Greenest’ Data Center in San Francisco Importance Factor = 1.5 and meets code for essential services Financial District SOMA UC Berkeley Lawrence Berkeley Labs UCSF (Tech Companies) Mid-Market St. (Start-Ups) Mission Bay 400 PAUL (Bio-Tech) San Francisco South San Francisco Bio-Tech All San Francisco 200 Paul Stanford University Metro loops converge PAIX Palo Alto on Paul Avenue. Silicon Valley sits 55 South Market San Jose directly on the main fiber ring serving the Bay Area, and connects to large fiber hubs such as PAIX in Palo Alto, 55 South Market and 11 Great Oaks in San Jose. 11 GREAT OAKS San Jose LOCATION = FIBER CONNECTIVITY Adjacent to 200 Paul Ave., one of the most densely connected Internet Gateways in the United States Ideally situated between the two major north-south fiber routes connecting San Francisco to Silicon Valley 200 Paul TELECOM CARRIERS in close proximity to 400 PAUL • AT&T • Astound Broadband • Centurylink • FiberLight • Integra • Level 3 Communications • opticAccess • Sunesys • TelePacific Communications • TeliaSonera • tw telecom • Verizon • XO Communications • Zayo • Zayo Dark Fiber Long Haul Carriers: • AT&T • CenturyLink • Cogent • Level 3 Communications • Sprint • Time Warner Telecom • Verizon • XO Communications • Zayo With more than 15 fiber networks and 40 different service providers in the immediate area, 400 Paul will offer an extremely dense mix of carriers that deliver the full spectrum of network services. Tenants will have multiple options for metro, long haul, international, and specialized services, as well as a full complement of products including dark fiber, private line, IP, cable TV, voice, and wireless. 400 Paul will also be well connected to the other major Data Centers, key exchanges and traffic hubs in the Bay Area and beyond. CARRIER NEUTRAL INTERCONNECTION ROOM 400 Paul will provide at least two physically remote Points of Entrance (POE) and construct a Meet Me Room (MMR) to accommodate all telecom carriers, fiber providers and Internet Service Providers (ISPs) on a Carrier Neutral basis. This MMR will act as an Internet Exchange Point (IXP) enabling individual entities to exchange internet traffic between and among their networks by means of mutual peering agreements, all at reasonable costs. 400 Paul will dedicate the IXP physical space with the requisite staffing, redundant power and cooling and diverse fiber routes for the purpose of establishing a robust and reliable Open IX (OIX) Operation within the facility. 400 Paul’s independent OIX Operation will provide Tenants with professional, high quality, non-blocking peering service for all types of IP traffic, from regular IP data (e.g., e-mail and web content) to video/TV content, hosting and cloud bandwidth. Peering at 400 Paul’s OIX can improve network performance (shorter paths) and improve reliability (multiple paths to destinations) at the lowest possible cost. SYNOPSIS 400 Paul Ave. is the first new Data Center project constructed in San Francisco in 14 years. Designed with state-of-the art electrical and mechanical systems, 400 Paul will include a new purpose-built Data Center building, constructed from the ground up, plus two renovated classic 1930’s era buildings to provide needed support space adjacent to the Data Halls. Scalable, flexible and robust describe this “Tenant Driven” Project designed to accommodate full-floor tenants (up to 88,000 SF per floor) as well as individual Data Halls (from 9,500 SF) in a multi-tenant environment. The 187,000 SF two-story Data Center structure provides heavy floor load capacity, generous 20’ structural height, efficient support areas and shafts to the roof for efficient outside-air cooling. The 135,000 SF of usable Data Hall space is open and continuous on each floor without fixed shafts or demising walls interrupting efficient cabinet layouts. The architecturally significant Spanish Colonial Revival building and the Modernist Industrial style building will be renovated to house modern and efficient office space (up to 36,000 SF), a secure entrance lobby, a new “core”, and secure storage space (up to 13,000 SF) for tenants within steps of their Data Centers. SITE PLAN DEVELOPMENT TEAM 400 Paul is a development of The Cambay Group, one of the pioneering developers in the telecommunications and Data Center real estate industry. In 1999, the Cambay Group developed then leased one of the first and biggest Internet Gateway properties in the western U.S. In 2001 Cambay developed and leased the largest multi-tenant Data Center at that time in Santa Clara. Also known as “carrier hotels”, these properties remain relevant and essential nodes in today’s telecommunications infrastructure. The Cambay Group has developed over 1.3M SF of Internet Gateway and Powered Data Center Shell buildings for the IT and Telecommunications industry. In addition this proven sponsor has over 250,000 SF of Custom-Designed and Built-to-Suit Turnkey Data Center experience. The 400 Paul Development Team includes the “best-in-class” design, engineering and construction firms in our industry. FIRST FLOOR OPTIONAL ADDITIONAL DATA ROOM Data Hall Electrical Office Common SECOND FLOOR Data HallOfficeCommon BUILDING CAPACITY The new structure will be an efficient two-story approx. 187,000 SF structure • Approx. 135,000 SF of uninterrupted Data Hall space on two floors • Approx. 18,500 SF of Electrical Rooms on the 1st floor provide power to Data Halls on both floors Currently planned for 13 Data Halls sized between 9,500 SF and approx. 11,500 SF High capacity floor loading • Data Halls on both floors designed at 150psf • Electrical Rooms designed at 250psf Flexible Office Space is available for tech-ops, sales and marketing, and management personnel - 36,000 SF Secure Storage Space – up to 13,000 SF available Two elevators; one passenger and one freight for efficient vertical transportation Two loading docks with separate compacter bay to allow concurrent deliveries for multiple tenants FLEXIBLE AND CUSTOMIZABLE HIGH SECURITY Extremely flexible “Tenant Driven” design – no restrictive building standards Secure site with 24x7 manned security Tenant Selected electrical topology per Module – design for N+1 or 2N Perimeter security fencing with motion sensors and recognition-based detection software Tenant selected power density from 105 W/SF to 160 W/SF Accommodates 2.5 kW per cabinet to 8 kW per cabinet • 1,200 kW IT Capacity is standard (with DX cooled roof-top units) • 1,500 kW IT Capacity is available (with adiabatic cooling option) Perimeter CCTV surveillance Tenant Selected cooling systems: • 100% outside air economizer is standard • Compressor-less option is available with adiabatic cooling Secure storage Motorized vehicle gates Secured loading dock Multi-level Biometric readers and man-traps No pre-built demising walls – premises are customizable to Tenant’s requirements OUTSIDE AIR ECONOMIZER COOLING OUTSIDE AIR ECONOMIZER COOLING OUTSIDE AIR EXHAUST AIR OUTSIDE AIR PACKAGED DX ROOF‐TOP AC UNIT or ADIABATIC ROOF‐TOP UNIT PACKAGED DX ROOF‐TOP AC UNIT or ADIABATIC ROOF‐TOP UNIT Supply Air Return Air Return Air Supply Air Outside Air Intake on Sides of Unit Outside Air Intake on Sides of Unit ROOF ASSEMBLY HOT RETURN AIR PLENUM Bottom flange of beam HOT RETURN AIR PLENUM HOT RETURN AIR PLENUM 6'‐0" Ceiling COOL ROOM 14'‐0" COLD AISLE 96" Cabinets HOT AISLE Cabinets COLD AISLE Cabinets HOT AISLE Cabinets COLD AISLE Cabinets SECOND FLOOR STRUCTURE HOT AISLE Cabinets COLD AISLE Cabinets HOT AISLE Cabinets COLD AISLE SECOND FLOOR STRUCTURE HOT RETURN AIR PLENUM HOT RETURN AIR PLENUM Bottom flange of beam HOT RETURN AIR PLENUM Ceiling Ceiling COOL ROOM COLD AISLE 11'‐0" COLD AISLE 96" Cabinets HOT AISLE Cabinets COLD AISLE Cabinets COOL SUPPLY AIR PLENUM HOT AISLE Cabinets COLD AISLE 36" Raised Floor SLAB ON GRADE Cabinets HOT AISLE Cabinets COLD AISLE Cabinets COOL SUPPLY AIR PLENUM SLAB ON GRADE SCHEMATIC BUILDING SECTION - TYPICAL BAY Schematic Building Section ‐ Typical Bay ROBUST CONSTRUCTION Structural design with 1.5 importance factor Importance factor of 1.5 applied to MEP systems Modern structural steel braced-frame with pre-cast concrete wall panels Designed to the “essential services” building code standard LEED and Energy Star certificated roof membrane with a 20 year warranty HOT AISLE Cabinets SUPPLY AIR PLENUM 36" Raised Floor GREEN AND SUSTAINABLE HIGH EFFICIENCY EQUALS LOW PUE Compliant with CA SB 1953 – Green House Gas Legislation Designed for high efficiency Data Hall • Incorporates all roof-top air handling equipment for free cooling • Accommodates overhead air distribution and cold aisle containment • Designed to accommodate ASHRAE “Allowable Operating Conditions” LEED certified design Sustainable site Low power consumption cooling systems Design incorporates 97% efficiency IGBT based UPS systems Annualized PUE will range between 1.22 and 1.28 Average Hours at Temperature per Year AVERAGE HOURS AT TEMPERATURE PER YEAR WITH DATA HALL COOLING MODES with Data Hall Cooling Modes AVERAGE HOURS / YEAR Average Hours/Year 3,000 2,500 Outside Air Economizer & Humidifcation 548 Hours/Year 2,000 Adiabatic Cooling 61 Hours/Yr Operating Window 55 dF ‐‐ 80 dF 20% ‐ 70% RH DX or Adiabatic Cooling 148 Hours/Year Operating Window 60 dF ‐‐ 75 dF 20% ‐ 60% RH Outside Air Economizer 8,151 Hours/Year 1,500 Outside Air Economizer & Humidification 309 Hours/Year 1,000 Outside Air Economizer 8,303 Hours/Year 500 0 31 35 39 43 47 51 55 59 63 67 71 75 79 83 87 91 95 99 103 Dry Bulb Temperature DRY BULB TEMPERATURE POWER COOLING 24MVA of utility power provided at 12,470 volts • Two 12 MVA circuits from diverse transformers in PG&E Substation • Reliable and safe underground duct-bank Packaged roof-top Unit with DX cooling and 100% Outside Air economizer section Low power costs estimated to be between $0.10 - $0.12/kWh Emergency water storage on site for 24-hour continuous adiabatic cooling Back-up power provided by 18 Cummins 2MW standby generators configured in N+1 Fuel storage for 24 hours continuous operation Custom ‘Roof-Top’ Unit with adiabatic cooling that eliminates all mechanical cooling (i.e. a compressor-less option) Raised Access Floor option for underfloor supply air plenum Cold Aisle or Hot aisle containment options with OH air distribution PROPERTY HIGHLIGHTS • Extremely flexible design allows for many different size and electrical/mechanical density deployments • Approximately 135,000 USF of flexible design Data Hall space available • Low power costs estimated between $0.10 - $0.12/kWh • Approximately 36,000 SF of flexible office space • PUE range between 1.22 and 1.28 depending on mechanical design selected • 13,000 SF of storage space available • Multiple and redundant paths from Paul Avenue in to the Carrier Neutral Building MMR with 40 - 4” conduits • Green and sustainable design • Multiple carriers including AT&T, CenturyLink, Level3, Verizon, tw telecom, opticAccess, Cogent, XO, Zayo, IPNet, Internap, Pacnet, Telekenex, T-Mobile, BT Americas, Clear Wireless, Hibernia, IPC, BCE Nexxin and Layer 42 at Paul Avenue • Secure/fenced site with 24-hour manned security • Floor to floor height at 20 feet provides - 36” raised floor plus 11’ ceiling height - Flat floor with 14’ ceiling height B e t t e r ...C o n n e c t e d Chris Sumter Executive Vice President Chris.Sumter@am.jll.com +1 650 354 3346 +1 925 786 8722 (cell)