VPE Dry Type Distribution Transformers 112.5 kVA Through 15,000 kVA 600V Through 35 kV Primary Voltage 120V Through 15 kV Secondary Voltage --do- 111111 r"r'r Quality Products...Built With Pride ABB transformer factories in 30 countries. Our people make certain that our world renowned quality is exemplified by every product that bears the ABB name. An experienced and dedicated work force ensures the quality of our work and your satisfaction with our products. We strive for operational excellence, lowest manufacturing cost, and short cycle times. ABB's mission is to be the leader in delivering quality products and services for generation, transmission and distribution, industrial processes, mass transit, and environmental control that meet the needs and requirements of our customers and contribute to their success. To ensure customer satisfaction, ABB provides value-added, integrated solutions that are driven by superior technology and performance. ABB employees are committed to leadership in applying the company's unique conibination of experience and global resources to meet societal goals for sustainable growth and clean energy. VPE (Vacuum Pressure Encapsulated) transformers provide enhanced moisture protection with extended life expectancy. ABB developed the Silicone VPE dr y type transformer to meet the stringent shipboard applications for the U.S. Navy. VPE utilizes the inherent bonding strength of multiple layers of silicone varnish as a sealant. This proven process provides excellent dielectric strength and the silicone remains pliable even after thermal aging. The finished coating remains smooth and gives superior environmental protection against moisture, dust, dirt, salt air, and most industrial contaminants, y making it ideall suited for demanding applications. Silicone VPE transformers achieve high efficiency ratings with low maintenance and operating costs. Silicone VPE transformers are non-explosive with high resistance to flame and do not Military certifications in addition to ISO-9001 , UL. GSA. and Nuclear 1 OCFR50 compliance demonstrate ABB's commitment to providing quality transformers for utility. industrial. and commercial end users. The Silicone VPE Process require vaults, containment dikes, or expensive fire suppression systems. Product Scope: • 112.5 kVA-15,000 kVA • Primary Voltages: 600V-35 kV • Primary BIL: Up to 150 kV • Secondary Voltages: 120V-15 kV • Secondary BIL: Up to 75 kV Temperature Rise 8011151150°C To provide the ultimate protection against moisture, the silicone VPE process utilizes a special four cycle procedure that employs the fundamental principles of vacuum pressure encapsulation and curing. Because of the inherent bonding strength of silicone varnish, the finished coating remains smooth and gives superior environmental protection. Coils receive a minimum of 4 cycles of silicone varnish, and the core and clamping structure are coated with a corrosion resistant sealant that guards against moisture and industrial contaminants. Silicone varnish provides excellent dielectric strength that remains pliable even after thermal aging. The silicone varnish is a true 220°C insulating material tested to above 250°C. VPE Benefits/Advantages • Enhanced moisture protection • No danger of fire or explosion • No liquids to leak • Low L initial cost • 220-C Insulation Class • ISO 9001 Registered • Emergency Support: Quick Ship Option (5 day turnaround) • Custom Coordination • On Site Service • TechnicaI Support The silicone VPE process utilizes conventional dry t ype designs and offers optional conductors, BIL levels, and temperature rises with a 220°C Class insulation system. This advanced process provides the ultimate in overload capacity. The nominal coating of silicone varnish received through the silicone VPE process provides excellent dielectric strength. The varnish has been tested, after immersion in water for 24 hours, and still maintained a dielectric strength of 1500 volts per Anil. When cured, the silicone varnish meets, or exceeds, UL 94 VO flammability tests and has a rating of 39 when coated over Nomex Aramid paper. Core and Coil Construction Core Construction ABf3's VPE transformers utilize a step-lap mitered core construction to ensure optima in performance and mininial sound levels. The mitered core joints aIIow efficient flux Transfer along natural grain Iines between the core legs and yoke. The step-lap construction further enhances Low voltage coils are sheet wound for short circuit integrity. Computer controlled high voltage disk winding. the efficiency of the joint by reducing joint fringing, which reduces core losses and exciting current. The core is designed and built to provide the ii lowest possible losses from the effects of magnetic hysteresis and eddy currents. All possible steps arc taken to prevent IocaI circulating currents and to avoid built-in Step-lap mitered core joints are utilized for efficiency and noise reduction. Bus connections made using bolted connections. bending stresses. Coil Construction 2500 kVA are typically round. As part of the quality process, ABB starts with non-aging, high permeability, ABB's winding construction depends on cold-rolled, grain oriented silicon steel for operating voltage, basic impulse level, ABB's low voltage VPE windings, core construction. Magnetic flux densities and current capacity of the individual insulation class 1.2 kV (600V) and are kept well below the saturation point. winding. Unless there is a customer below, are typically wound using sheer The steel is precision cut to assure that it preference, winding design is based conductors. This construction allows wiII be smooth and burr-free. For rigidity upon total optimization and need not be free current distribution within the axial and support, the upper and lower yokes specified. width of the coil which eliminates the are solidly clamped with steel support axial forces developed in other types of windings under short circuit conditions. members. Tie plates connect the top and Whenever possible, transformers are bottom clamps and provide a rigid constructed with sheet wound secondary structure for lifting. windings and wire wound primary The primary coil is wound directly over windings. the secondary coil and is separated by an insulating barrier. The finished core is coated with a corrosion resistant sealant which provides Winding construction may be either lamination cohesion and the round or rectangular through 2500 kVA AIuminum conductors are standard. environmental protection that is needed for VPE coils. Windings on VPE Copper conductors are available as an for high humidity areas. transformers with ratings greater than option. 3 Indoor/Outdoor Application 0 VPE transformers are utilized in some of the harshest indoor and outdoor environments Outdoor Enclosure i maginable. While core and coil technologies have been enhanced to combat caustic and hurnid environments, VPE transformers still require the protection of a properly designed enclosure. An enclosure which flexes or bends under high wind loading can compromise electrical clearances from the transformer to the enclosure, which can lead to transformer NEMA1 Indoor Enclosure failures as well as electrical safety hazards. An enclosure that allows excess water entry into the enclosure also poses undue risk. ABB designs have been tested for extreme weather requirements and the mechanical stresses associated with seismic criteria. ABB's enclosure designs have been used along coastal areas and frigid northern slopes where high winds and driving rain are common. Custom enclosures with special paint colors are available. ABB enclosures are custom fabricated using heavy gauge sheet steel as standard. Alum iii uin and stainless are also available. Electrostatically deposited dry powder paint, baked onto a phosphatcd surface, provides added protection against harsh outdoor or indoor environments. A variety of options ranging from NEMA 2 drip-proof roofs to filters, screens, hinged panels, and special hardware can be added. ABB's dry powder stateof-the-art paint system keeps enclosures looking new for years. Modifications can be made to extend the enclosure, add bottom plates, add end sheets, and special cut-outs for specific applications. 4 T?AI H Forced Air Cooling Increases kVA Capacity Provisions for future fan cooling (FFA) Whcn specified, VPF, transformers, can be supplied with provisions for futu re forced air cooling. This option includes bus work rated for increased current capacity and provisions for future installation of fans and fn control equipment. Forced air cooling (AA/FA) VPE transformers, when specified, can be supplied with forced air cooling. Forced air cooling equipment includes fans, control wiring, thermal sensors, and a three phase electronic temperature monitor. The temperature sensors are located in the low voltage windings and are factory connected to the three phase winding temperature monitor which controls the forced air cooling automatically. Typical forced air cooling increases the rated capacity of VPE transformers 33 1/3% on units up to 5000 kVA and 25% for units 5001 kVA and larger. Electronic Temperature Monitor (ETM) The ETM combines temperature indication and fin control functions for the transformer and accepts input from three thermal sensors. The three phase electronic temperature monitor tracks the transformer temperature with automatic displays and functions. Typical location of thermocouple. Features: • Digital temperature display • I Tottest winding temperature is automatically displayed • Temperature of any single winding can be displayed • Maximum temperature can be recalled even if the supply power has been interrupted • Fan, alarm, and trip functions are controlled b y the hottest winding temperature • DPDT contacts are provided for fin, alarm, and trip functions • Contacts are dry • Alarm relay is fail-safe • Fans can be manually operated • Includes internal sonic alarm, which can be temporarily silenced without canceling the alarm circuit • Isolation box to separate gauge from energized components • Alarm reset can be automatic or manual with auto condition start-up • State-of-the -art solid state construction • UI, component recognized • Non-magnetic Type E thermocouple standard • Easy retrofit with existing panels • Open thermocouple circuits are detected and indicated, but do not affect instrument operation • Accepts 1 15 or 230 VAC supply power • Form C relays. Optional Features • Fan exerciser (programmable) will energize fans once per week • Remote communication available through RS-232 port. Standard Enclosure Design Dimension & Weights Height Width Depth Weight Inches (mm) Inches (mm) Inches (mm) Lbs. (kg) 113 90 (2286) 78 (1981) 60 (1524) 2250 (1022) 113 225 90 (2286) 78 (1981) 60 (1524) 2850 (1294) 300 , 90 (2286) 78 (1981) 60 (1524) 500 90 (2286) 78 (1981) 750 90 (2286) 1000 kVA Height Width Depth Weight Inches (mm) Inches (mm) Inches (mm) Lbs. (kg) 90 (2286) 78 (1981) 60 (1524) 2950 (1339) 225 90 (2286) 90 (2286) 60 (1524) 4250 (1930) 3200 (1453) 300 90 (2286) 90 (2286) 60 (1524) 4650 (2111) 60 (1524) 4350 (1975) 500 90 (2286) 96 (2438) 66 (1676) 6350 (2883) 84 (2134) 60 (1524) 5450 (2474) 750 90 (2286) 1 02 (2591) 66 (1676) 8150 (3700) 90 (2286) 84 (2134) 66 (1676) 6250 (2838) 1 000 90 (2286) 1 02 (2591) 66 (1676) 9200 (4177) kVA • I 1500 90 (2286) 84 (2134) 66 (1676) 8150 (3700) 1 500 1 02 (2591) 1 08 (2743) 66 (1676) 1 2,050 (5471) 2000 90 (2286) 96 (2438) 66 (1676) 9350 (4245) 2000 1 02 (2591) 114 (2896) 66 (1676) 1 4,850 (6742) 2500 90 (2286) 1 02 (2591) 66 (1676) 11,050 (5017) 2500 112 (2845) 1 26 (3200) 66 (1676) 1 8,550 (8422) 3000 1 02 (2591) 108 (2743) 66 (1676) 14,750 (6697) 3000 112 (2845) 1 44 (3658) 66 (1676) 20,850 (9466) Values listed are typical and should not be used for construction purposes Quality Assurance Optional Tests: The following tests are made on all 1. Impulse Tests-full and chopped- transformers unless noted as an wave Tests per ANSI and NEMA exception. The numbers shown do not standards necessarily indicate the sequence in 3. Audible Sound Level Test latest revision ofANST C57.12.91 4. Induced Partial Discharge Test Code for Transformers. 5. Temperature Test on the tap extremes on one unit of a given rating on a multiple unit order 6. Insulation Power-factor Test y L TRANSFORMER SP^ 8. Short Circuit Test 9. Seismic Qualification. Standards and Certifications ANSI C57.12.00 3. Polarit and Phase-relation Tests ANSI C57.12.91 4. No-load loss at rated voltage ANSI N45.2-1977 5. Excitation current at rated voltage UT. 6. Impedance and load loss at rated NRC IOCFR50 Appendix B current on the rated voltage ISO 9001 connection of each unit and on NEMA ST20 the tap extremes on one unit of a GSA Z 299.3 given rating on a multiple unit MIL-I-45208A order Qualified for Inanufacture of Nuclear Class 7. Applied Potential Tests 1-E, Safety Rclared Transformers including 8. Double Induced Potential Test. IEEE 344 Certi fi cation. 6 R 7. Switch and Soak Test 2. Ratio Tests on the rated voltage connection and all tap connections O (100% full wave) will be made in accordance with the windings on the rated tap and C LISTED 9300 BU DISTRIBUTION 2. Qualit y Control Impulse Test which the tests will be made. All tests 1. Resistance measurements of all U U LISTED 93DO DISTRIBUTION TRANSFORMER Specifications 112.5-15,000 Up to 150 Up through 35 • Aluminum windings—copper optional 80/115/1500 UI, listing CSA certification 2. Step-lap mitered core 220°C Up to 75 Options & Accessories Standard VPE Features 3. Up through 15 insulation system-150°C average Nuclear 1 E certification: IEEE 323— qualified life temperature rise 4. Vacuum pressure encapsulation with silicone varnish 5. Four (4) full-capacity raps on I IV winding rated 2-1/2% 2- FCAN-2-FCBN on units with voltage IEEE 344—seismic certification NEMA 3R enclosure 80°C or 115°C average temperature rise Copper windings above 601 V 6. NEMA I heavy-gauge ventilated enclosure with Provisions for future fan cooling (FFA) Three-phase electronic temperature monitor removable panels from and rear 7. ANSI 61 gray paint electrostatically applied using dry Forced cooling package with three-phase electronic temperature monitor powder 8. Vibration isolation pads between core and coil and Increased basic impulse levels boss optimized designs enclosure 9. Base equipped with jacking pads and designed for rolling or skidding enclosure in any direction 10. Provisions for lifting core and coil assembly Air-filled terminal chambers __ Special paint colors Retrofit designs 11. Diagrammatic aluminum nameplate 12. 100% QC Impulse Test 13. Short Circuit Design Verification Temperature Rise/Overload Capacity 150 ` C 115 - C 1000 1000 80°C 1000 1000 1150 1350 1333 1530 1800 VPE transformers are constructed with 220°C class insulation and have a maximum temperature nse of 1 S0'C. When ordered with 115C rise, the VPE transformer (if specified) will have a 115% continuous overload capablity (153% with tans). AA/FA/FA VPE transformers, when ordered with a 80°C rise (if specified). will have a 135% continuous overload capability (180% with tans). AA/FA/FA Electronic Temperature Monitor provided with isolation barrier for added safety. Altitude Derating Factor Standard Transformer Ratings Primary Voltage Class 500V through 34.5 kV 150C rise 3 0 C average ambient x x — 3300 1 50 X X — 4000 .994 .989 .98 225 X X — 5000 .985 .974 .95 6000 .975 .959 .92 x 7000 .966 .944 .89 8000 .957 .929 .86 .83 112 1/2 — — 300 400 400 x X 500 667 667 X X I 1.00 1.00 1.00 750 1 000 1000 X x _ _ x 1000 1 333 1 333 X X X 9000 .948 .914 1 000 1 333 1 333 X X X 10,000 .939 .898 .80 .930 .883 .77 1 500 2000 2000 X x 2000 2666 2666 — X x x 11.000 1 2,000 .921 .868 .75 2500 3333 3333 — X X 1 3,000 .912 .853 .72 X 1 4.000 .903 .838 .70 X 1 5.000 .894 .823 .67 3750 4687 5000 6250 4687 — 6250 • 7500 9375 9375 1 0,000 12,000 12,000 4 X X NOTE: 3.28 FT = 1 Meter "X" denotes standard or available. BIL's Associated Voltages Audible Sound Levels 1.2 S 2.5 ' 5.0 0-9 40 0-1167 67 10-50 45 1168-1667 68 15.0 1 1 S 1 ^^ S 8.7 51-150 50 1 668-2000 69 25.0 151-300 55 2001-3333 71 34.5 301-500 60 3334-5000 73 501-700 62 5001-6667 6668 8333 74 75 1 1 S 1 1 1 S 1 1 2 S 1 1 2 S 701 1000 64 1001-1500 65 NOTES: S = Standard value. 1 = Optional higher levels where exposure to overvoltage occurs and improved protective margins are required. 2 = Lower levels where protective characteristics of applied surge 1501-2000 66 arresters have been evaluated and tound to provide appropriate surge protection. 2001-3000 68 3001-4000 70 4001-5000 71 5001-6000 72 6001-7500 75 Impedance Chart 112.5-500 None Specified 5.75% 501 & Larger ` 5.75% 5.75% For Units with 60 kV Primaries and below. –For Units with 208V Secondaries, the standard impendance value will he 5.0% guaranteed minimum. 8 1 Specification Guide The transformer shall be of dr y rypc Vacuum Pressure Encapsulated class. The basic impulse level shall be inherent to the winding (VPE) construction, and shall be mounted in a suitably design and is to be obtained without the use of supplemental ventilated (indoor, outdoor) enclosure. surge arresters. The transformer shall be manufactured by a compan y which is certified to ISO 9001:1994, EN ISO 9001:1994; B EN ISO 9001:1994; ANSIIASQC Q9001: 1994 for design and manufacture of Power, Distribution and Specialty Dry Type Transformers. A certificate of Compliance to this requirement shall be provided with the proposal. The transformer shall be rated kVA with a primary voltage of kV (delta,wye) connected and have a BIT, rating of y kV and a secondar voltage of V (dclra,wye) connected and have a BIT. rating of kV. The transformer is to have an impedance (per manufacturer's standard, %IZ.) The average temperature rise of the transformer windings shaII be rated at (80"C, 115C, 150°C) and shall be built utilizing Class 220 C insulations, regardless of the temperature rise specified. The transformer shall not exceed the specified temperature rise when the unit is operated continuously at fuII nameplate rating. The transformer shall be capable of carrying 100% of the nameplate rating in a 30"C average, not to exceed 40°C maximum ambient in any 24 hour period. The high voltage and Iow voltage windings shall be constructed usin g (copper, aluminum) conductors. The o conduct rs shall be insulated with a 220'C insulation. Transformer windings, insulation class 1.2 kV (60OV) and below, shall be wound using foil or sheet conductors. Transformer windings, insulation class 2.5 kV (2400V) and above, shall be wound using wire conductors. The high voltage winding shall be wound over the low voltage wincing with sufficient mechanical bracing to prevent movement during fault conditions and sufficient solid Class 220 ° C insulation to isolate the high voltage winding dielectric potential from the Iow voltage windings. The transformer core shall be constructed of high grade non-aging silicon steel laminations with high magnetic permeability and Iow hysteresis and edd y current Iosses. Magnetic Flux densities are to be kept well below the saturation point. A step-lap mitered core joint shall be used to minimize losses, exciting currents and sound levels. The core laminations shall be clamped together with heavy steel members. The completed coil assembl y is to be vacuum pressure encapsulated via a multi-cycle process which meets the requirementsof MIL -I-24092. This process requires that coils receive a minimum of four (4) c ycles of silicone varnish and the core and clamping structure receive a minimum of two (2) cy cles of corrosion resistant sealant. The varnish shall be applied in consistent coatings to give a uniform shield of silicone varnish. The VPE process shaII effectivel y encapsulate the entire core and coil assembl y which results in a unit which is virtually i mpermeable to moisture, dust, dirt, salt air and other industrial contaminants. The transformer shall have vibration isolation pads installed between core and coil assembl y and enclosure base structures to prevent the transmission of structure borne vibration. The impulse rating of the transformer must equal or exceed the basic impulse level specified b y ANSI for the applicable voltage The enclosure shaII be constructed of heavy gauge sheet steel and shaII be finished in ANSI 61 paint color. The paint shall be applied using an electrostatically deposited dry powder paint s y stem. All ventilating openings shall be in accordance with NEMA and the NEC standards for ventilated enclosures. The base of the enclosure shall be furnished withround pads located on opposite diagonal corners. The base shall have jacking pads and shall be constructed of heavy steel members to permit skidding or rolling in any direction. The core shall be visibly grounded to the frame by means of a Flexible grounding strap. Forced air cooling, when required, shall increase the continuous self cooled rating of the transformer b y 33 1/3% on units throughh 5000 kVA and by 25% on unitsreater than 5000 kVA. The FA increase shall be possible with forced cooling without exceeding the specified maximum temperature rise. The forced air cooling shall be regulated automaticall y b y sensors placed in the low voltage winding's air ducts. Forced air cooling shall include: three phase electronic digital temperature monitor, fans, control wiring, control panel with test switch, indicator lights, alarm and alarm silencing switch. When 80`C and 115 ` C winding temperature rise are specified, they can be designed with inherent overload capabilities. An 80"C rise unit shall 'be capable of continuous operation at 35% above nameplate rating and a ii 5 ° C rise unit shall be capable of continuous operation at 17% above nameplate rating when specified. This overload capability would be achieved on the AA and FA rating and shall be accomplished by allowing the transformers ultimate rise to be 150'C. Customer specification must define the high capacity overloads. Transformer shaII be furnished with a non-corrosive diagrammatic nameplate per ANSI C57.12.01, permanently attached with non-corrosive hardware. The diagrammatic nameplate shall include the name of the manufacturer of the transformer as well as the location where the transformer was manufactured and tested. In addition, the transformer manufacturer and location of manufacture is to be supplied at the ti me of quotation. After completion, each transformer shall undergo the following routine tests per ANSI C57.12.01 and ANSI CT.57. 12.91. Testing shall be accomplished using calibrated test equipment which have recorded accuracy traceable to National Institute of Standards Technologies (MST). Certification of Calibration shall be provided with test reports, if requested. In addition to routine testing a 100% QC Impulse Test shall be performed on each transformer furnished. Routine Tests • Meggcr • Ratio • Resistance • Phase relation • Load Loss, Impedance and Regulation • No Load Loss and Excitation Current • 100% QC Impulse Test • AppIied Potential Test • Induced Potential Test