trans - Nav-Tech

advertisement
TRANS “S” AND SWITCH COMBINATION
400AAMP.,
240V/480
VOLT
CON
400
MP., 240
VOLT CON
EDISON
- LEDISON
INE TOP - LINE TOP
CATALOG NUMBERS:
TS/SW-400-240T
CATALOG
NUMBER TS/SW-400-240T
1 2 .1 2 5
2 1 .2 5
6 5 .0 0
2 1 .5 0
J305
"J"
1 2 .1 2 5
1.
CABINET SHALL BE RATED NEMA I (INDOOR ONLY) AND SHALL BE
CONSTRUCTED FROM CODE GAUGE GALVANIZED OR GALVANEALED STEEL.
9.
2.
BUS BAR SHALL BE SILVER OR TIN PLATED AND SHALL BE SIZED PER THE NEC.
3.
BUS BAR SHALL BE MOUNTED IN THE CABINET BY MEANS OF STANDOFF
INSULATORS OR INSULATED MOUNTING BRACKETS. INSULATING MATERIALS
SHALL CONFORM TO THE APPLICABLE SECTIONS OF UL 746 AND UL 94.
CABINET SHALL BE UL, CON EDISON AND N.Y.C. ADVISORY BOARD APPROVED.
10. ONLY FACTORY PREFABRICATED KNOCKOUTS ON THE ENCLOSURE SHALL
BE USED.
4.
THE CABINET IS INTENDED FOR CABLE ENTRY THROUGH BOTTOM AND EXIT
THROUGH THE TOP ONLY..
5.
THE SHORT CIRCUIT CAPABILITY OF THE CABINET ASSEMBLY SHALL BE RATED
AT 200,000 RMS SYMMETRICAL AMPERES WITH CLASS "J" FUSES.
6.
THE FUSED POWER CIRCUIT DEVICE REQUIRES 400AMP, 250V MAX., CLASS "J"
FUSES (NOT PROVIDED).
7.
INSULATED SLEEVING SHALL BE PROVIDED WHERE MULTICONDUCTOR
BUNDLE PASSES UNDER NEUTRAL BAR. WIRE MOUNTS ARE RIVETED IN
PLACE.
8.
THE UNIT IS MARKED "SUITABLE FOR USE AS SERVICE EQUIPMENT"..
USE ONLY MANUFACTURER’S APPROVED LUG PROVIDED. EACH LUG IS RATED
FOR (1) 600 MCM-#4 OR (2) 250MCM-#4 CABLE.
11. PROVIDE PREWIRED TRANS "S" UNIT WITH #12 AWG STRANDED (19/25) THHN
COPPER COLOR CODED WIRE FROM THE TEST SWITCH TO THE SOCKET
ASSEMBLY AND FROM THE TEST SWITCH TO THE METERING COMPARTMENT
INTO C.T. COMPARTMENT. LEAVE 7 FT. OF WIRE FOR FUTURE CONNECTION TO
CURRENT TRANSFORMERS. USE EITHER HOOK OR RING TYPE TINNED
COPPER LUGS FOR TERMINATIONS. ALL WIRING IN ACCORDANCE WITH CON
EDISON MES #751, FOR FORM 9S METER SOCKET.
12. NEAREST LIVE PARTS ARE 24" MINIMUM TO FLOOR.
13. THE UNIT IS SHIPPED WITH AN "INSULATED NEUTRAL" AND A BOUNDING KIT
("BK8") PROVIDED WITH INSTRUCTIONS (FOR INSTALLATION AS REQUIRED BY
CONTRACTOR).
14. SECURITY HARDWARE TO BE PROVIDED FOR CT CABINET DOOR AND METER
ENCLOSURE (TO BE INSTALLED BY CONTRACTOR).
15. 265/460 VOLT SERVICE REQUIRES A DISCONNECT SWITCH BEFORE THE CT
CABINET.
Phone: (718) 272-4222 • Fax: (718) 272-4226
navtechelect@yahoo.com
12
TRANS “S” AND SWITCH COMBINATION
400
AMP.,
VOLT
CON -EDISON
- LINE BOTTOM
400 A
MP., 2240V/480
40 VOLT CON
EDISON
LINE BOTTOM
CATALOG
NUMBERS:
TS/SW-400-240B
CATALOG NUMBER TS/SW-400-240B
1.
CABINET SHALL BE RATED NEMA I (INDOOR ONLY) AND SHALL BE
CONSTRUCTED FROM CODE GAUGE GALVANIZED OR GALVANEALED STEEL.
9.
2.
BUS BAR SHALL BE SILVER OR TIN PLATED AND SHALL BE SIZED PER THE NEC.
3.
BUS BAR SHALL BE MOUNTED IN THE CABINET BY MEANS OF STANDOFF
INSULATORS OR INSULATED MOUNTING BRACKETS. INSULATING MATERIALS
SHALL CONFORM TO THE APPLICABLE SECTIONS OF UL 746 AND UL 94.
CABINET SHALL BE UL, CON EDISON AND N.Y.C. ADVISORY BOARD APPROVED.
10. ONLY FACTORY PREFABRICATED KNOCKOUTS ON THE ENCLOSURE SHALL
BE USED.
4.
THE CABINET IS INTENDED FOR CABLE ENTRY THROUGH BOTTOM AND EXIT
THROUGH THE TOP ONLY..
5.
THE SHORT CIRCUIT CAPABILITY OF THE CABINET ASSEMBLY SHALL BE RATED
AT 200,000 RMS SYMMETRICAL AMPERES WITH CLASS "J" FUSES.
6.
THE FUSED POWER CIRCUIT DEVICE REQUIRES 400AMP, 250V MAX., CLASS "J"
FUSES (NOT PROVIDED).
7.
INSULATED SLEEVING SHALL BE PROVIDED WHERE MULTICONDUCTOR
BUNDLE PASSES UNDER NEUTRAL BAR. WIRE MOUNTS ARE RIVETED IN
PLACE.
8.
THE UNIT IS MARKED "SUITABLE FOR USE AS SERVICE EQUIPMENT"..
13
USE ONLY MANUFACTURER’S APPROVED LUG PROVIDED. EACH LUG IS RATED
FOR (1) 600 MCM-#4 OR (2) 250MCM-#4 CABLE.
11. PROVIDE PREWIRED TRANS "S" UNIT WITH #12 AWG STRANDED (19/25) THHN
COPPER COLOR CODED WIRE FROM THE TEST SWITCH TO THE SOCKET
ASSEMBLY AND FROM THE TEST SWITCH TO THE METERING COMPARTMENT
INTO C.T. COMPARTMENT. LEAVE 7 FT. OF WIRE FOR FUTURE CONNECTION TO
CURRENT TRANSFORMERS. USE EITHER HOOK OR RING TYPE TINNED
COPPER LUGS FOR TERMINATIONS. ALL WIRING IN ACCORDANCE WITH CON
EDISON MES #751, FOR FORM 9S METER SOCKET.
12. NEAREST LIVE PARTS ARE 24" MINIMUM TO FLOOR.
13. THE UNIT IS SHIPPED WITH AN "INSULATED NEUTRAL" AND A BOUNDING KIT
("BK8") PROVIDED WITH INSTRUCTIONS (FOR INSTALLATION AS REQUIRED BY
CONTRACTOR).
14. SECURITY HARDWARE TO BE PROVIDED FOR CT CABINET DOOR AND METER
ENCLOSURE (TO BE INSTALLED BY CONTRACTOR).
15. 265/460 VOLT SERVICE REQUIRES A DISCONNECT SWITCH BEFORE THE CT
CABINET.
Phone: (718) 272-4222 • Fax: (718) 272-4226
navtechelect@yahoo.com
TRANS “S” AND SWITCH COMBINATION
800
240V/480
VOLT
CON -EDISON
800 AAMP.,
MP., 240
VOLT CON
EDISON
LINE TOP- LINE TOP
CATALOG
NUMBERS:
TS/SW-800-240T
CATALOG NUMBER TS/SW-800-240T
1.
CABINET SHALL BE RATED NEMA I (INDOOR ONLY) AND SHALL BE
CONSTRUCTED FROM CODE GAUGE GALVANIZED OR GALVANEALED STEEL.
2.
BUS BAR SHALL BE SILVER OR TIN PLATED AND SHALL BE SIZED PER THE NEC.
3.
BUS BAR SHALL BE MOUNTED IN THE CABINET BY MEANS OF STANDOFF
INSULATORS OR INSULATED MOUNTING BRACKETS. INSULATING MATERIALS
SHALL CONFORM TO THE APPLICABLE SECTIONS OF UL 746 AND UL 94.
CABINET SHALL BE UL, CON EDISON AND N.Y.C. ADVISORY BOARD APPROVED.
4.
THE CABINET IS INTENDED FOR CABLE ENTRY THROUGH TOP AND EXIT
THROUGH THE BOTTOM ONLY..
5.
THE SHORT CIRCUIT CAPABILITY OF THE CABINET ASSEMBLY SHALL BE RATED
AT 200,000 RMS SYMMETRICAL AMPERES WITH CLASS "L" FUSES.
6.
THE FUSED POWER CIRCUIT DEVICE REQUIRES 800AMP, 250V MAX., CLASS "L"
FUSES (NOT PROVIDED).
7.
INSULATED SLEEVING SHALL BE PROVIDED WHERE MULTICONDUCTOR
BUNDLE PASSES UNDER NEUTRAL BAR. WIRE MOUNTS ARE RIVETED IN
PLACE.
8.
THE UNIT IS MARKED "SUITABLE FOR USE AS SERVICE EQUIPMENT"..
9.
USE ONLY MANUFACTURER’S APPROVED LUG PROVIDED. EACH SINGLE LUG
IS RATED FOR (1) 600 MCM-#4 OR (2) 250MCM-#4 CABLE. EACH DOUBLE LUG ON
SWITCH SIDE IS RATED FOR (2) 600MCM-#4 CABLE.
10. ONLY FACTORY PREFABRICATED KNOCKOUTS ON THE ENCLOSURE SHALL
BE USED.
11. PROVIDE PREWIRED TRANS "S" UNIT WITH #12 AWG STRANDED (19/25) THHN
COPPER COLOR CODED WIRE FROM THE TEST SWITCH TO THE SOCKET
ASSEMBLY AND FROM THE TEST SWITCH TO THE METERING COMPARTMENT
INTO C.T. COMPARTMENT. LEAVE 7 FT. OF WIRE FOR FUTURE CONNECTION TO
CURRENT TRANSFORMERS. USE EITHER HOOK OR RING TYPE TINNED
COPPER LUGS FOR TERMINATIONS. ALL WIRING IN ACCORDANCE WITH CON
EDISON MES #751, FOR FORM 9S METER SOCKET.
12. NEAREST LIVE PARTS ARE 24" MINIMUM TO FLOOR.
13. THE UNIT IS SHIPPED WITH AN "INSULATED NEUTRAL" AND A BOUNDING KIT
("BK8") PROVIDED WITH INSTRUCTIONS (FOR INSTALLATION AS REQUIRED BY
CONTRACTOR).
14. SECURITY HARDWARE TO BE PROVIDED FOR CT CABINET DOOR AND METER
ENCLOSURE (TO BE INSTALLED BY CONTRACTOR).
15. 265/460 VOLT SERVICE REQUIRES A DISCONNECT SWITCH BEFORE THE CT
CABINET.
Phone: (718) 272-4222 • Fax: (718) 272-4226
navtechelect@yahoo.com
14
TRANS “S” AND SWITCH COMBINATION
800
240V/480
VOLT
CON -EDISON
- LINE BOTTOM
800 AAMP.,
MP., 240
VOLT CON
EDISON
LINE BOTTOM
CATALOG
NUMBERS:
TS/SW-800-240B
CATALOG NUMBER TS/SW-800-240B
1.
CABINET SHALL BE RATED NEMA I (INDOOR ONLY) AND SHALL BE
CONSTRUCTED FROM CODE GAUGE GALVANIZED OR GALVANEALED STEEL.
2.
BUS BAR SHALL BE SILVER OR TIN PLATED AND SHALL BE SIZED PER THE NEC.
3.
BUS BAR SHALL BE MOUNTED IN THE CABINET BY MEANS OF STANDOFF
INSULATORS OR INSULATED MOUNTING BRACKETS. INSULATING MATERIALS
SHALL CONFORM TO THE APPLICABLE SECTIONS OF UL 746 AND UL 94.
CABINET SHALL BE UL, CON EDISON AND N.Y.C. ADVISORY BOARD APPROVED.
4.
THE CABINET IS INTENDED FOR CABLE ENTRY THROUGH BOTTOM AND EXIT
THROUGH THE TOP ONLY..
5.
THE SHORT CIRCUIT CAPABILITY OF THE CABINET ASSEMBLY SHALL BE RATED
AT 200,000 RMS SYMMETRICAL AMPERES WITH CLASS "L" FUSES.
6.
THE FUSED POWER CIRCUIT DEVICE REQUIRES 800AMP, 250V MAX., CLASS "L"
FUSES (NOT PROVIDED).
7.
INSULATED SLEEVING SHALL BE PROVIDED WHERE MULTICONDUCTOR
BUNDLE PASSES UNDER NEUTRAL BAR. WIRE MOUNTS ARE RIVETED IN
PLACE.
8.
THE UNIT IS MARKED "SUITABLE FOR USE AS SERVICE EQUIPMENT"..
9.
USE ONLY MANUFACTURER’S APPROVED LUG PROVIDED. EACH SINGLE LUG
IS RATED FOR (1) 600 MCM-#4 OR (2) 250MCM-#4 CABLE. EACH DOUBLE LUG ON
SWITCH SIDE IS RATED FOR (2) 600MCM-#4 CABLE.
10. ONLY FACTORY PREFABRICATED KNOCKOUTS ON THE ENCLOSURE SHALL
BE USED.
11. PROVIDE PREWIRED TRANS "S" UNIT WITH #12 AWG STRANDED (19/25) THHN
COPPER COLOR CODED WIRE FROM THE TEST SWITCH TO THE SOCKET
ASSEMBLY AND FROM THE TEST SWITCH TO THE METERING COMPARTMENT
INTO C.T. COMPARTMENT. LEAVE 7 FT. OF WIRE FOR FUTURE CONNECTION TO
CURRENT TRANSFORMERS. USE EITHER HOOK OR RING TYPE TINNED
COPPER LUGS FOR TERMINATIONS. ALL WIRING IN ACCORDANCE WITH CON
EDISON MES #751, FOR FORM 9S METER SOCKET.
12. NEAREST LIVE PARTS ARE 24" MINIMUM TO FLOOR.
13. THE UNIT IS SHIPPED WITH AN "INSULATED NEUTRAL" AND A BOUNDING KIT
("BK8") PROVIDED WITH INSTRUCTIONS (FOR INSTALLATION AS REQUIRED BY
CONTRACTOR).
14. SECURITY HARDWARE TO BE PROVIDED FOR CT CABINET DOOR AND METER
ENCLOSURE (TO BE INSTALLED BY CONTRACTOR).
15. 265/460 VOLT SERVICE REQUIRES A DISCONNECT SWITCH BEFORE THE CT
CABINET.
15