Laars® Combi Heat™ Residential Energy Saver Gas Water Heater System The Laars® Combi Heat™ Flammable Vapor Ignition Resistant Models Feature (50 gallon model only): ■ Advanced Flame Arrestor—Flame arrestor is designed to prevent ignition of flammable vapor outside of the water heater. ■ Resettable Thermal Switch—Proven and reliable bimetallic switch prevents burner and pilot operation in case of ongoing flammable vapor burn inside of the combustion chamber or restricted air flow. ■ Pedestal Base—Rugged and durable base allows easy transport and positioning, and provides corrosion resistant contact with floor. ■ Maintenance Free—Regular cleaning of air inlet openings or flame arrestor is not required under normal conditions. ■ Sight Window—Offers a view into the combustion chamber to observe the operation of the pilot and burner. ■ Piezo Igniter—Easy and quick lighting of the pilot burner by push button. Photo is of LCH-504T10FBN All Laars® Combi Heat™ Models Feature: ■ Heat Exchanger—Double wall 11⁄2" O.D. glass coated steel coil ensures separation of potable water and heating fluid. ■ Low Heat Exchanger Head Loss—Up to 10 GPM flow, with less than 5 ft. of head loss. Greatly reduces the required pump size for heat exchange. ■ Glass Lined Tank—LAARS Heating Systems water heater tanks are protected from the corrosive effects of hot water by an exclusive ceramic porcelain-like coating. ■ Fully Automatic Controls—Built-in energy cut-off switch prevents abnormally high water temperature for extra safety. Built-in gas pressure regulation. ■ Steel Tank—Heavy gauge steel automatically formed, rolled and welded to assure a continuous seam for glass lining. ■ Thermostatic Mixing Valve—Supplied with unit to help prevent injury due to scalding. ■ Protective Aluminum Anode Rod—Provides added protection against corrosion for long trouble-free service. ■ Flue Baffle—Designed to maximize the amount of heat absorbed in the lower portion of tank. Reduces air movement in the heater during standby periods to retard heat loss up the flue. ■ Factory Installed Sediment Reduction System—Cold water inlet sediment reducing device. Helps prevent sediment build up in tank. Increases first hour delivery of hot water while minimizing temperature build up at top of tank. ■ Water Connections—3⁄4" NPT factory installed true dielectric fittings. Extends water heater life and eases installation. ■ 2" Non-CFC Foam Insulation—Surrounds the tank surface, saving energy by retarding loss of heat. ■ T&P Relief Valve—Installed. ■ Brass Drain Valve. ■ Design Certified by CSA International (formerly AGA/CGA). 10-Year Limited Tank and Heat Exchanger Warranties / 6-Year Limited Warranty on Component Parts. For products installed in USA, Canada and Puerto Rico. Some states and provinces do not allow limitations on warranties. See complete copy of the warranty included with the heater. MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S. PATENTS: 7,063,133 B2; 5,954,492; 5,761,379; 5,943,984; 5,081,696; 5,988,117; 6,142,216; 5,199,385; 5,574,822; 5,372,185; 5,485,879; 5,277,171; (B1)5,341,770; 5,660,165; 5,596,952; 5,682,666; 4,904,428; 5,023,031; 5,000,893; 4,669,448; 4,829,983; 4,808,356; 5,115,767; 5,092,519; 5,052,346; 4,416,222; 4,628,184; 4,861,968; 4,672,919; Re. 34,534. OTHER U.S. AND FOREIGN PATENT APPLICATIONS PENDING. CURRENT CANADIAN PATENTS: 1,272,914; 1,280,043; 1,289,832; 2,045,862; 2,112,515; 2,108,186; 2,107,012; 2,092,105 Laars® Combi Heat™ Direct Fired Gas Water Heater System Deluxe Energy Saver Models Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed 80% Recovery Efficiency NATURAL GAS AND LIQUID PROPANE GAS Model Number LP Nat. Nat. Nat. U.S. Imp. BTU/Hr. BTU/Hr. U.S. Imp. Gal. Gal. Input Input GPH GPH LCH-504T10FBN LCH-75T10BN Model Number LCH-504T10FBN LCH-75T10BN 45 72 A B Floor to Jacket Flue Dia. LP LP Conn. U.S. Imp. in. in. GPH GPH Recovery 90°F Rise* Capacity 38 61 70 81 65,000 61,000 76,000 76,000 66 81 59 70 Recovery 50°C Rise* Capacity 59 1⁄4 63 3⁄4 55 70 Liters Nat. kW Input LP kW Input Nat. Liters/ Hour LP Liters/ Hour 170 272 19.1 22.3 17.9 22.3 265 317 250 317 22 26 A B Floor to Jacket Flue Dia. Conn. C Vent Dia. in. H K Approx. F G E D J Floor Floor Floor Floor to Floor Top Depth Shipping to to to Weight to T&P Water Conn. Gas Exchanger Exchanger Top of Conn. Inlet Outlet Heater Conn. in. in. in. in. lbs. in. in. in. 4 4 C Vent Dia. mm. mm. mm. 1403 1530 559 660 102 102 50 53 13 16 277⁄8 307⁄8 50 53 563⁄8 601⁄4 57 611⁄4 241⁄2 281⁄2 238 328 K Approx. H G F E D J Floor Floor Floor Floor to Floor Top Depth Shipping to to to Weight to T&P Water Conn. Gas Exchanger Exchanger Top of Conn. Outlet Heater Inlet Conn. mm. mm. mm. mm. mm. kg. mm. mm. 1270 1346 330 406 1505 1619 1505 1619 1432 1619 1447 1556 108 149 622 724 All Propane heaters are equipped with a cast iron burner. To order a Propane heater change suffix “BN” to “CX”. *Based on manufacturers rated recovery efficiency. C Heat Exchanger Head Loss GPM Ft. of Hd. Loss 2 trace 5 0.4 8 2.3 10 4.6 12 6.9 K B D&G A LCH-504T10 Model Number LCH-75T10 FBN FCX BN CX 105 U.S. Gal. .55 100 U.S. Gal. .55 135 U.S. Gal. .52 135 U.S. Gal. .52 80.0 80.0 82.0 I Water Heating❂ J FHD H CAEF Space Heating CAAFUE% F E Max. Heating Capacity✦ 55,000 BTU/Hr. (16.1 kW) 82.0 55,000 BTU/Hr. (16.1 kW) ❂ Based on ANSI Z-21.10.1 and 10.3 and DOE Test Methods. ✦ Based on ANSI/ASHRAE 124 Standard. Actual values may vary based on circulator flow rate, number of zones, water and space heating demands. Numbers subject to change. Note: (C-DW2-75T will not have a pedestal base) All natural gas models meet SCAQMD Requirements. Meets NAECA Requirements General All gas water heaters are certified at 300 PSI test pressure (2068 kPa) and 150 PSI working pressure (1034 kPa). All potable water and heat exchanger connections are 3⁄4" NPT (19mm) on 11" (203mm) centers. All gas connections 1⁄2" (13mm). All models design certified by CSA International (formerly AGA/CGA), ANSI Z-21.10.1 and or 10.3 and peak performance rated. Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement. Suitable for Water (Potable) Heating and Space Heating Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into the potable water side. The potable side of this unit may NEVER be connected to any existing heating system or component(s) previously used with a non-potable water heating appliance. The heat exchanger side of the unit may be used in space heating applications. 800.900.9276 • Fax 800.559.1583 (Customer Service, Service Advisors) 20 Industrial Way, Rochester, NH 03867 • 603.335.6300 • Fax 603.335.3355 1869 Sismet Road, Mississauga, Ontario, Canada L4W 1W8 • 905.238.0100 • Fax 905.366.0130 www.Laars.com Litho in U.S.A. © Laars Heating Systems 0806 Document 11020 F