quick-dry anti-oxidene coating

advertisement
QUICK-DRY
ANTI-OXIDENE
COATING
 PROTECTS AGAINST RUST
 ADHESIVE AND PENETRATING
POWERS
 FOR METAL SURFACES
 FOR CONCRETE SURFACES
QUICK-DRY ANTI-OXIDENE COATING helps protect metal from
moisture, acid fumes, salt-air mist, and silage acid.
 VERSATILE
 ECONOMICAL
QUICK-DRY ANTI-OXIDENE COATING is a unique
asphalt coating. It took many years of research to produce.
It will withstand the constant attack of rust and corrosion
on metal. It was primarily developed to protect outdoor
metal surfaces under normal conditions. Tests have shown,
however, QUICK-DRY ANTI-OXIDENE COATING has good
resistance to moisture, acid fumes, salt-air mist, and silage
acid. It is recommended for coastal areas and industrial sites
everywhere.
QUICK-DRY ANTI-OXIDENE COATING
Protects Against Rust
Exposed metal surfaces are in constant danger from
rust and corrosion. If the damage is not detected early and
corrected, it could mean major extra expense to you. With
QUICK-DRY ANTI-OXIDENE COATING, you get protection
against damaging rust and corrosion for virtually all metal
surfaces. Its quick-drying action helps prevent further damage
- - practically eliminating any chance of rust on new surfaces.
QUICK-DRY ANTI-OXIDENE COATING
Has Adhesive and Penetrating Powers
QUICK-DRY ANTI-OXIDENE COATING is a jet-black,
easy-to-apply asphalt coating. Its special formulation allows it
to penetrate into corroded areas and retard further spreading.
For best results, remove rust and scale before applying
QUICK-DRY ANTI-OXIDENE COATING. It is pliable enough
to allow it to expand and contract with the metal, without
losing its protective bond. Normal stresses of that type
can crack a regular paint surface. The great adhesive and
penetrating powers of this product give it a superior bond to
metal or concrete. On metal surfaces, it protects against rust
and corrosion caused by moisture, most dilute acids, alkalies,
salt water or salt spray, stack fumes and other pollutants.
On concrete surfaces, it protects against deterioration from
industrial fumes, salt, moisture, or other airborne pollutants.
The concrete, whether it is slab or block construction, lasts
longer and functions more effectively. At the same time, repair
costs are substantially reduced or eliminated.
QUICK-DRY ANTI-OXIDENE COATING
For Metal Surfaces
For metal surfaces, preparation of the surface is
important. It should be free of scale, dirt, peeling paint, rust
flakes, or any other loose material. You can accomplish such
cleaning by use of a wire brush or scraper, cleaning away all
this material - - rusted areas need not be scraped down to
bright metal. The surface must be dry. New galvanized steel
must be cleaned and allowed to weather for three months
prior to application. On exterior surfaces, drying time is about
four hours. A second coat may be applied after that time. It
is recommended that two coats be applied where corrosive
conditions such as acid rain or salt water exist. Coverage
rates on metal are about one gallon of QUICK-DRY ANTIOXIDENE COATING to 300 square feet.
QUICK-DRY ANTI-OXIDENE COATING
For Concrete Surfaces
For concrete surfaces, the surface must be cleaned and
dry. Use a stiff-fiber brush to remove any loose scale or other
loose materials. Do not apply over painted surfaces. The
first coat will cure in approximately four hours. The first coat
coverage rate will be from 100 to 200 square feet per gallon
of QUICK-DRY ANTI-OXIDENE COATING. After the first coat
has cured, apply the second coat at the rate of one gallon
for each 200 to 300 square feet. The final coat should cure
in approximately 72 hours, depending on the humidity levels.
Remember, the product is applied directly as it comes from
the container. There is no mixing required and should not be
diluted. During application of the product, it will appear jetblack; however, as it cures and weathers, it turns a brownishblack color.
QUICK-DRY ANTI-OXIDENE COATING
Is Versatile
There is a need for this product all around you. Some of
those areas include the following:
Metal storage sheds, metal roofs, trestles, bridges,
girders and beams, interiors and exteriors of metal
warehouses. In addition, you will find concrete abutments,
interior of concrete sewer pipes, concrete and metal
structures exposed to water, salt water or sewage. You also
have cast iron pipes and fittings, racks, oil drilling equipment,
and derricks. Let's not forget farm, construction and mining
equipment, water and chemical tanks, towers and prestressed concrete structures. In particular, buildings of block
construction have vulnerability at the mortar joints. You can
stop the acid deterioration of those joints.
QUICK-DRY ANTI-OXIDENE COATING
Is Economical
QUICK-DRY ANTI-OXIDENE COATING is a low cost
item in the long run. It assures protection and of course, it is
many times less costly than building new metal or concrete
buildings. In addition, it is less costly than other metal and
concrete paints. You get a good coverage rate of 300 square
feet of metal surface for each gallon of QUICK-DRY ANTIOXIDENE COATING. You can even get good coverage with
a single coat on smooth surfaces. Concrete surfaces require
a little more product and two coats are suggested; but with
the low cost of this product, you can apply QUICK-DRY ANTIOXIDENE COATING for only a few pennies per square foot.
QUICK-DRY ANTI-OXIDENE COATING is applied
directly as it comes from the container. There is no mixing
required and the product should not be diluted. The product
can be applied by a brush or appropriate spray equipment.
Please note paints with a non-asphalt base will not bond
with QUICK-DRY ANTI-OXIDENE COATING.
SPECIFICATIONS
QUICK-DRY ANTI-OXIDENE COATING
Product Code: #3076
QUICK-DRY ANTI-OXIDENE COATING yields the following typical results:
Specific Gravity @ 60°F (15.5°C)
Pounds per gallon @ 60°F (15.5°C)
Consistency
.91
7.58
Brush or Spray
Flash Point, PMCC
Viscosity @ 122°F (50°C) Saybolt Furol
Asphalt Content, Wt. %
1040F (400C)
45
55
Drying Time, 1 mil Dry film thickness:
To Touch, Minutes, maximum
Through, maximum
Hard, Hours, maximum
20
40
24
Properties of Original Base Asphalt:
Softening Point (Ring & Ball)
Penetration @ 77°F. (25°C)
190°F (88°C)
6
Properties of Solvent used to make QUICK-DRY ANTI-OXIDENE COATING:
Gravity, API @ 60°F (15.5°C)
Specific Gravity @ 60°F (15.5°C)
Pound per Gallon @ 60°F (15.5°C)
52.2
0.77
6.43
Distillation, ASTM D-86
Initial Boiling Point
End Point
310°F (154.4°C)
330°F (165.6°C)
Handling Information: For safe handling of the product, read the Safety Data Sheet (SDS).
Not for sale in California.
Toll Free: 1-800-827-0711
Toll Free Fax: 1-800-582-3329
www.texasrefinery.com
E-mail: lube1@texasrefinery.com
TEXAS REFINERY CORP
Fort Worth, Texas
Toronto, Ontario • Moose Jaw, Saskatchewan
PRINTED IN U.S.A. 5/2014
L303076
Download