CASAMBI EXPRESS CBU-ASD CBU-TED Description You can change your ambiance according to your mood by dimming, changing the colour of the light or adjust the colour temperature according to your daylight conditions. The Casambi devices are smart on their own The system itself is self healing and in constant synchronization. The Casambi devices are connected when needed via Bluetooth connection. An Internet connection is not necessary. The system is intuitive. Very small form factor for luminaire installation. Just Plug it in the lighting fixture. No other configurations by a professional technician are needed. CBU-ASD CBU-ASD is a wireless control unit for LED and halogen drivers with 0-10V, 1-10V or DALI dimming interface. The control output can be configured either as analog 0-10V (and 1-10V) or digital Standalone DALI control interface. CBU-ASD can be controlled with Casambi app, available for iOS and Android devices, as well as with traditional wall switches. Accessoires CBU-TED Xpress CBU-TED is a Bluetooth controllable, Casambi enabled trailing-edge dimmer for operation of incandescent lamps, dimmable LED lamps and dimmable LED control gear. It can be installed behind a traditional wall switch, inside a luminaire or into a ceiling outlet box. Xpress is a wireless user interface that can be configured via the Casambi app. The four target buttons can control a scene or an animation of the user’s choise or simply one luminaire, one luminaire group or all lamps together if so desired. CBU-TED can be controlled with Casambi app, available for iOS and Android devices, as well as with traditional wall switches. Different Casambi enabled products can be used as a simple one luminaire direct control to a complete and full featured light control system where up to 127 units form automatically an intelligent mesh network. PLT PROFESSIONAL LIGHTING TECHNICS CE+T Technics - 17 Rue Hauzeur, B-4031 Angleur (Belgique) T +32 (0)4 340 46 60 • www.cettechnics.be • info@cettechnics.be • TVA BE-0451.953.484 Descri • Use timers to turn on and off scenes at predefined times. ENGLISH • Define the security of the network. There are four different security levels for access control. www.casambi.com CBU-ASD Being a member of the Casambi solution CBU-TED uses the Casambi Bluetooth Low Energy mesh network to control the luminaires. The strength of mesh network is the perfect control of multiple luminaires in a same network without gateways, routers, repeaters or extra wiring. CBU-TED andLED other Casambi family products use Bluetooth Low Energy to form a direct connection Bluetooth control unit for drivers between a mobile device and the Casambi product. Casambi CBU-TED complements other Casambi enabled products with mains voltage dimming. It is possible to use a single Warning! Casambi product to control one luminaire or multiple Casambi products to create a perfect light control system. Hazardous voltages. Risk of electric shock or fire. Only qualified professionals CBU-TED should make the connections. DisconWIRING DIAGRAM nect the mains power supply and verify its absence prior to installation. Wiring Diagram ! To connect a wire, press the button on top of the dimmer and insert the stripped wire into the wire hole as far as it goes. directly powered DALI or 0-10V drivers L 85-240 VAC Wiring diagram, 50-60 Hz DALI2)/ 0-10V Connected wires can be released by pressing the button again. N Wall switch or fixedNote mains1. voltage 230 VAC L N 220-240V~ L N N Suitable for drivers that can be switched off via control interface DA/+ DA/LED driver L Analog / D igital dimming control N Wire info: Solid and stranded: 0,5-1,5 mm2/16-20 AWG max. 0.6A High voltage halogen, AC LED modules, 230 dimmable LED and CFL bulbs or VAC trailing L edge dimmable LED drivers Strip length: 6-8 mm CasambiDIAGRAM Technologies Oy WIRING CBU-ASD ! Warning! Hazardous voltage. Risk of electric shock. Only qualified professionals LEDshould module make the connections. Page 1 of 3 Linnoitustie 4 A 02600 Espoo, Finland www.casambi.com info@casambi.com tel. +358 10 501 2950 CBU-TED Fact Sheet v1.0.6 Copyright 2015 Wiring diagram, directly powered DALI or 0-10V drivers Suitable for drivers that cannot be switched off via control interface 230 VAC 1-10V L N N L max. 0.6A Analog / D igital dimming control 220-240V~ L N 230 VAC When as a po withou it poss temper CBU-A an exis a lighti CBU-A Blueto a large needed Install N Warning! Do not connect more than one kind of load at a time. CBU-A dimmin or digi + - Make s 1,5 mm Insert to con L and letters and - s If you i outlet specifi LED driver L N Ran External relay LED module ! Warning! Risk of fire. Do not connect CBU-ASD mains output directly to LED driver mains input Dimensions Mounting diameter: PLT PROFESSIONAL LIGHTING TECHNICS CE+T Technics - 17hole Rue Hauzeur, B-4031 Angleur (Belgique) T +32 (0)4 340 46 60 • www.cettechnics.be • info@cettechnics.be • TVA BE-0451.953.484 2 x 3.5 mm 1) Range EXPLICATION SOLUTION CASAMBI CBU-ASD Technical facts CBU-TED Technical facts Input 220-240 VAC 50 Hz 0,6 A Dimming method Trailing-edge phase control Max. output current 0,65 A Input 85-240 VAC 50-60 Hz 0,65 A Min. load requirement 1W Mains Output 220-240 VAC 50 Hz SSR op faselijn Output 0-10 V 0-10V DC/Dali (1ch/2ch/3ch/4ch) 7mA Dimensions 56,5 x 35,8 x 22,3 mm Protection IP20 Built-in Class II Output Incandescent and high voltage halogen bulbs: 150 W @ 230 VAC 70 W @ 110 VAC High voltage AC LED modules: 150 W @ 230 VAC 70 W @ 110 VAC Max. current pulse 4A Dimensions 40,4 x 36,3 x 14,0 mm Protection IP20 Dimmable LED and CFL bulbs: 50 W @ 230 VAC 25 W @ 110 VAC Dimmable electronic transformers: 50 W @ 230 VAC 25 W @ 110 VAC PLT PROFESSIONAL LIGHTING TECHNICS CE+T Technics - 17 Rue Hauzeur, B-4031 Angleur (Belgique) T +32 (0)4 340 46 60 • www.cettechnics.be • info@cettechnics.be • TVA BE-0451.953.484