Circuit Breakers 40-630 Amp 40 OF8451 #8 45 OF8451 #8 50 OF8451 #8 55 OF8451 #6 60 OF8451 70 OF8451 75 OF8451 80 OF8451 90 OF8451 100 OF8451 125 OF8451 150 OF8451 160 OF8451 2/0 Derate by Temperature 175 OF8451 2/0 180 OF8451 3/0 200 OF8451 3/0 225 OA7822 250 OA7822 300 OA7822 350 OA7822 400 OA7822 450 OF8452 500 OF8452 600 OF9721 630 OF9721 1-600 MCM #4 or 2-250 MCM to 2-1/0 Mounting 70 in lbs. Wire Lug is 375 in lb. 2-500 MCM-750 MCM Al/Cu 480 in lbs. 3-2/0-400 MCM Al/Cu 480 in lbs. #6 #4 #4 #3 #3 200 Amp Frame #4 #1 1/0 4/0 250 MCM 350 MCM 500 MCM 600 MCM 400 Amp Frame Single Hole 0.656 Dia. #6 to 300 MCM Copper or Aluminum Single Conductor Only Mounting Bolt 70 in lbs. Wire Lug is 375 in lbs. Wire Size per 310-16* Frame Lug Part # C.B. Rated Current........................ 225-400 Amps Interrupt Rating...................... 25,000 Amps Trip......................................... Thermal Magnetic Curve..................................... #200 Rating Temperature............... 40°C Frame Size............................ 400 Amp Rated Current........................ 450-630 Amps Interrupt Rating...................... 35,000 Amps Trip......................................... Thermal Magnetic Curve..................................... #200 Rating Temperature............... 40°C Frame Size............................ 800 Amp Temperature °C 20 30 40 50 Rated Current 110 105 100 95 700 MCM or 2-4/0 2-250 MCM 2-350 MCM or 3-3/0 2-400 MCM 800 Amp Frame Lug Description Rated Current........................ 40-200 Amps Interrupt Rating...................... 18,000 Amps Trip......................................... Thermal Magnetic Curve..................................... #200 Rating Temperature............... 40°C Frame Size............................ 200 Amp C.B. Amps * Section 240.4 of the 2005 NEC allows the next higher standard overcurrent device rating above the ampacity of the conductors being protected provided the next higher rating does not exceed 800 amperes. Because of derates and individual AHJ preferences, that was not taken into account in the above chart. All circuit breakers are UL 489 Listed for 208, 240, 480 Volts Trip Curve on back side. CIRCUIT BREAKERS COORDINATION TRIP CURVE LEHF0043-00 (06/09) Information contained in this publication may be considered confidential. Discretion is recommended when distributing. Materials and specifications are subject to change without notice. CAT, CATERPILLAR, OLYMPIAN, their respective logos and ''Caterpillar Yellow'', as well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission. www.CAT-ElectricPower.com © 2009 Caterpillar All rights reserved. Printed in U.S.A.