24.01 400SS – Screw Spline Curtainwall Description Description WAUSAU Tubelite 400SS Screw Spline Curtainwall is an exterior glazed, thermally improved pressure wall system. This gasket glazed, weeped system will accept infill material up to 1” thick, positioned at the frame exterior for a minimum of metal exposure. A screw applied pressure plate secures the infill material and snap fits with a cover plate to conceal fasteners and allow for two color installations. Open-back jambs and 2-piece intermediate verticals allow screw spline joints. This reduces the need for shear blocks, fabrication time and installation labor costs. 400SS Curtainwall has a 2½” sight-line and is available in variable deptsh from 5 7/8" to 13 ¼" through face cover / backmember combinations. It is recommended for use on low to medium rise structures. 2007 STOREFRONT, CURTAINWALL & ENTRANCES 24.02 400SS – Screw Spline Curtainwall Guide Specifications General Description Furnish all necessary materials, labor and equipment for the complete installation of aluminum framing as shown on the drawings and specified herein. 400SS Curtainwall framing is manufactured by WAUSAU Tubelite Inc., Reed City, Michigan. Submit substitute product technical literature, samples, drawings and performance data ten (10) days prior to bid in order to make a valid comparison of the products involved. Performance Requirements Air infiltration shall not exceed 0.01 cfm/ft2, when tested in accordance with ASTM E-283 “Rate of Air Leakage through Exterior Windows” at a test pressure of 6.24 PSF. There shall be no uncontrolled water entry when tested in accordance with ASTM E-331 “Water Penetration of Exterior Windows, Curtainwalls and Doors by Uniform Static Air Pressure Difference” at a test pressure of 15 PSF. There shall be no buckling, stress on glass, edge seal failure, excess stress on curtainwall structure, anchors and fasteners, or reduction in performance when tested in accordance with AAMA 501.5-98, at a temperature range of 0° to 180° F. There shall be no “Life/Safety” type failures (glass breakage, anchor failures, or structural damage) when tested in accordance with AAMA 501.4, seismic test (lateral cycling). Structural performance shall be based on a maximum allowable deflection of L/175 of the span, or ¾” maximum. The system shall perform to these criteria when subjected to a wind load of (architect specify) _____ PSF. Thermal transmittance due to conduction (Uc) shall not be greater than 0.65 BTU/hr/ft2/F°, and the Condensation Resistance Factor of the framing (CRF) shall not be less than 68, when tested in accordance with AAMA 1503.1-98. Products Materials Extrusions of aluminum alloy 6063-T5 or 6063-T6 (as required), are manufactured within commercial tolerances and free from defects impairing strength and/or durability. Main framing sections and pressure plates to be of .090 inch minimum wall thickness and snap covers to be of .050 inch minimum thickness. Screws, bolts and other accessories are compatible with the aluminum under normal service conditions. July 2004 Finish All exposed framing surfaces are free of scratches and other serious blemishes. Finish to be: (architect select) Etched and clear anodized (AAM12C22A31) Class 2 Clear (0A) (AAM12C22A41) Class 1 Clear (2A) Electrically deposited color (AAM12C22A44) Champagne (4K) Light Amber (2K) Amber (1K) Bronze (3K) Black (0D) Tubelite Standard 50% PVDF Paint Bone White (1P) Hartford Green (2P) Black (3P) Brick Red (4P) Sandstone (5P) Quaker Bronze (6P) Burnt Sun (7P) Sage Brown (8P) Boysenberry (9P) Aegean Blue (0P) Ivory (AP) Beige (BP) Light Sea Wolf (CP) Military Blue (DP) Polar White (EP) Custom 50% or 70% PVDF As selected Execution Installation Installation shall be in accordance with the manufacturer’s installation instructions and the approved shop drawings. Note: WAUSAU policy of continuing In keeping with Tubelite’s product improvements, all specifications are subject to change without written notice by the manufacturer. WAUSAU WAUSAU WAUSAU WAUSAU WAUSAU WAUSAU WAUSAU WAUSAU WAUSAU WAUSAU WAUSAU WAUSAU WAUSAU WAUSAU 400 Screw Spline Curtainwall CAD DETAIL FILE NO. 295SCREW Anti Buckle Set Screw Detail P1221 E3851 7 1/2" 5 1/4" E3850 S204 1/4-20 x 1/4" SOCKET HEAD SET SCREW AS REQUIRED TO RESTRICT SPREADING. USE THREAD LOCKING ADHESIVE. 1 1/2" P2003 P2064 P2002 E4TB64 3/4" M4TB63 S403 2 1/2" 2010 *SEALANT, ROD, & ANCHORS NOT BY TUBELITE WAUSAU WAUSAU WAUSAU WAUSAU WAUSAU WAUSAU 24.24 400 Series Screw Spline Curtainwall Structural Values Shape Area(in.2) Ixx(in.4) Sxx (in.3) Iyy(in.4) Syy(in.3) Description E3840 3 3/4" Open Back Vertical - Male Half 1.534 4.036 1.617 0.686 0.515 E3841 3 3/4" Open Back Vertical - Female Half 0.730 1.363 0.710 0.068 0.070 E3842 3 3/4" Open Back Butt Glaze Vertical - Male Half 1.253 2.564 1.343 0.603 0.422 E3843 3 3/4" Open Back Butt Glaze Vertical - Female Half 0.814 1.558 0.776 0.084 0.090 E3844 3 3/4" Tubular Horizontal 1.597 3.758 1.484 1.434 1.147 E3845 3 3/4" Open Back Perimeter 1.412 4.217 1.658 1.110 0.758 E3846 3 3/4" Tubular Expansion Horizontal - Male Half 1.429 3.601 1.281 0.605 0.522 E3847 3 3/4" Open Back Expansion Horizontal - Female Half 0.973 2.796 0.974 0.127 0.158 E3850 5 1/4" Open Back Vertical - Male Half 1.721 8.342 2.591 0.780 0.552 E3851 5 1/4" Open Back Vertical - Female Half 0.918 3.159 1.183 0.073 0.073 E3852 5 1/4" Open Back Butt Glaze Vertical - Male Half 1.441 5.835 2.174 0.673 0.444 E3853 5 1/4" Open Back Butt Glaze Vertical - Female Half 1.002 3.587 1.286 0.092 0.094 E3854 5 1/4" Tubular Horizontal 1.867 7.978 2.478 1.826 1.461 E3855 5 1/4" Open Back Perimeter 1.547 8.357 2.457 1.231 0.794 E3856 5 1/4" Tubular Expansion Horizontal - Male Half 1.699 7.440 2.115 0.767 0.657 E3857 5 1/4" Open Back Expansion Horizontal - Female Half 1.108 5.459 1.456 0.142 0.167 T3847 3 3/4" Open Back Expansion Horizontal - Female Half 0.945 2.759 0.973 0.124 0.153 T3857 5 1/4" Open Back Expansion Horizontal - Female Half 1.080 5.371 1.450 0.138 0.161 July 2004 400SS-CWSECPROP