24.01 400SS – Screw Spline Curtainwall

advertisement
24.01
400SS – Screw Spline Curtainwall
Description
Description
WAUSAU
Tubelite 400SS Screw Spline Curtainwall is an exterior glazed,
thermally improved pressure wall system. This gasket glazed, weeped
system will accept infill material up to 1” thick, positioned at the frame
exterior for a minimum of metal exposure. A screw applied pressure
plate secures the infill material and snap fits with a cover plate to
conceal fasteners and allow for two color installations. Open-back
jambs and 2-piece intermediate verticals allow screw spline joints. This
reduces the need for shear blocks, fabrication time and installation
labor costs.
400SS Curtainwall has a 2½” sight-line and is available in
variable deptsh from 5 7/8" to 13 ¼" through face cover / backmember
combinations. It is recommended for use on low to medium rise
structures.
2007
STOREFRONT, CURTAINWALL & ENTRANCES
24.02
400SS – Screw Spline Curtainwall
Guide Specifications
General
Description
Furnish all necessary materials, labor and equipment
for the complete installation of aluminum framing as
shown on the drawings and specified herein.
400SS Curtainwall framing is manufactured by WAUSAU
Tubelite
Inc., Reed City, Michigan. Submit substitute product
technical literature, samples, drawings and performance
data ten (10) days prior to bid in order to make a valid
comparison of the products involved.
Performance Requirements
Air infiltration shall not exceed 0.01 cfm/ft2, when
tested in accordance with ASTM E-283 “Rate of Air
Leakage through Exterior Windows” at a test pressure of
6.24 PSF.
There shall be no uncontrolled water entry when
tested in accordance with ASTM E-331 “Water Penetration
of Exterior Windows, Curtainwalls and Doors by Uniform
Static Air Pressure Difference” at a test pressure of 15
PSF.
There shall be no buckling, stress on glass, edge seal
failure, excess stress on curtainwall structure, anchors and
fasteners, or reduction in performance when tested in
accordance with AAMA 501.5-98, at a temperature range
of 0° to 180° F.
There shall be no “Life/Safety” type failures (glass
breakage, anchor failures, or structural damage) when
tested in accordance with AAMA 501.4, seismic test
(lateral cycling).
Structural performance shall be based on a maximum
allowable deflection of L/175 of the span, or ¾” maximum.
The system shall perform to these criteria when subjected
to a wind load of (architect specify) _____ PSF.
Thermal transmittance due to conduction (Uc) shall
not be greater than 0.65 BTU/hr/ft2/F°, and the
Condensation Resistance Factor of the framing (CRF)
shall not be less than 68, when tested in accordance with
AAMA 1503.1-98.
Products
Materials
Extrusions of aluminum alloy 6063-T5 or 6063-T6 (as
required), are manufactured within commercial tolerances
and free from defects impairing strength and/or durability.
Main framing sections and pressure plates to be of .090
inch minimum wall thickness and snap covers to be of
.050 inch minimum thickness.
Screws, bolts and other accessories are compatible with
the aluminum under normal service conditions.
July 2004
Finish
All exposed framing surfaces are free of
scratches and other serious blemishes.
Finish to be: (architect select)
Etched and clear anodized
(AAM12C22A31)
Class 2 Clear (0A)
(AAM12C22A41)
Class 1 Clear (2A)
Electrically deposited color
(AAM12C22A44)
Champagne (4K)
Light Amber (2K)
Amber (1K)
Bronze (3K)
Black (0D)
Tubelite Standard 50% PVDF Paint
Bone White (1P)
Hartford Green (2P)
Black (3P)
Brick Red (4P)
Sandstone (5P)
Quaker Bronze (6P)
Burnt Sun (7P)
Sage Brown (8P)
Boysenberry (9P)
Aegean Blue (0P)
Ivory (AP)
Beige (BP)
Light Sea Wolf (CP)
Military Blue (DP)
Polar White (EP)
Custom 50% or 70% PVDF
As selected
Execution
Installation
Installation shall be in accordance with the
manufacturer’s installation instructions and the approved
shop drawings.
Note:
WAUSAU policy of continuing
In keeping with Tubelite’s
product improvements, all specifications are subject to
change without written notice by the manufacturer.
WAUSAU
WAUSAU
WAUSAU
WAUSAU
WAUSAU
WAUSAU
WAUSAU
WAUSAU
WAUSAU
WAUSAU
WAUSAU
WAUSAU
WAUSAU
WAUSAU
400 Screw Spline Curtainwall
CAD DETAIL FILE NO.
295SCREW
Anti Buckle Set Screw Detail
P1221
E3851
7 1/2"
5 1/4"
E3850
S204
1/4-20 x 1/4" SOCKET
HEAD SET SCREW AS
REQUIRED TO RESTRICT
SPREADING. USE THREAD
LOCKING ADHESIVE.
1 1/2"
P2003
P2064
P2002
E4TB64
3/4"
M4TB63
S403
2 1/2"
2010
*SEALANT, ROD, & ANCHORS NOT BY TUBELITE
WAUSAU
WAUSAU
WAUSAU
WAUSAU
WAUSAU
WAUSAU
24.24
400 Series Screw Spline Curtainwall
Structural Values
Shape
Area(in.2) Ixx(in.4) Sxx (in.3) Iyy(in.4) Syy(in.3)
Description
E3840
3 3/4" Open Back Vertical - Male Half
1.534
4.036
1.617
0.686
0.515
E3841
3 3/4" Open Back Vertical - Female Half
0.730
1.363
0.710
0.068
0.070
E3842
3 3/4" Open Back Butt Glaze Vertical - Male Half
1.253
2.564
1.343
0.603
0.422
E3843
3 3/4" Open Back Butt Glaze Vertical - Female Half
0.814
1.558
0.776
0.084
0.090
E3844
3 3/4" Tubular Horizontal
1.597
3.758
1.484
1.434
1.147
E3845
3 3/4" Open Back Perimeter
1.412
4.217
1.658
1.110
0.758
E3846
3 3/4" Tubular Expansion Horizontal - Male Half
1.429
3.601
1.281
0.605
0.522
E3847
3 3/4" Open Back Expansion Horizontal - Female Half
0.973
2.796
0.974
0.127
0.158
E3850
5 1/4" Open Back Vertical - Male Half
1.721
8.342
2.591
0.780
0.552
E3851
5 1/4" Open Back Vertical - Female Half
0.918
3.159
1.183
0.073
0.073
E3852
5 1/4" Open Back Butt Glaze Vertical - Male Half
1.441
5.835
2.174
0.673
0.444
E3853
5 1/4" Open Back Butt Glaze Vertical - Female Half
1.002
3.587
1.286
0.092
0.094
E3854
5 1/4" Tubular Horizontal
1.867
7.978
2.478
1.826
1.461
E3855
5 1/4" Open Back Perimeter
1.547
8.357
2.457
1.231
0.794
E3856
5 1/4" Tubular Expansion Horizontal - Male Half
1.699
7.440
2.115
0.767
0.657
E3857
5 1/4" Open Back Expansion Horizontal - Female Half
1.108
5.459
1.456
0.142
0.167
T3847
3 3/4" Open Back Expansion Horizontal - Female Half
0.945
2.759
0.973
0.124
0.153
T3857
5 1/4" Open Back Expansion Horizontal - Female Half
1.080
5.371
1.450
0.138
0.161
July 2004