> Broadband Power Total Power Solutions by ALPHA Technologies The Alpha Group - Total Power Solutions >Alpha Power Alpha pioneered the concept of reliable uninterruptible power for communications networks, and in the process has set a 35-year precedent for visionary, market-driven power solutions. Today, with millions of power systems installed worldwide, we continue to focus on providing the most reliable, innovative and energy efficient powering solutions. >Global Reach With millions of powering systems installed, and sales, manufacturing and service facilities located worldwide, we are able to help you in a language you’ll understand. This global reach gives us the expertise to provide your specific power solution. >Our Goal: Reducing Your Total Cost of Ownership >Reliability We are engineering the next generation of power technologies committed to reliability, cost savings and best-in-class performance. >Sustainability Running a more efficient powering network can reduce the resources consumed and your operational expenses. >Intelligence Instead of giving you data, intelligent products give you answers. We are working to provide the answers to optimize system performance. >Efficiency Through proper load matching and power supply sizing, tailored powering systems can perform at up to 94 percent efficiency. Table of Contents >Total Power Solutions 5-11 >Generators51-55 System Solutions....................................................6 AlphaGen™ Curbside............................................52 Installation and Construction Services...................7 Portable AC and DC Generators..........................53 Preventative Maintenance......................................8 AlphaGen™ Portable Trailer..................................54 Repairs and Refurbishments................................ 10 Customer Service................................................. 11 >AlphaCell® Batteries 57-63 AlphaCell 3.5HP and 4.0HP.................................58 >CableUPS Power Supplies 13-23 AlphaCell HP Runtime..........................................59 XM3-HP................................................................ 14 AlphaCell GXL......................................................60 XM2-HP................................................................ 18 AlphaCell GXL Runtime........................................61 XM2...................................................................... 19 AlphaCell..............................................................62 XM2-300HP.........................................................20 AlphaGuard™........................................................63 APB...................................................................... 21 Battery Testing Equipment...................................63 ® Smart Pack........................................................... 21 APX.......................................................................22 APP.......................................................................23 >Fiber Power 65-69 FlexPoint 12Vdc, RFoG.......................................66 ™ FlexPoint AX 12Vdc, PON.....................................67 >Status Monitoring 25-31 FlexNet™ 48Vdc 50W............................................68 AlphaNet™ DSM3 Family for XM2.........................26 FlexNet 48Vdc 150W............................................68 AlphaNet DSM3 Family for XM3-HP....................27 FlexNet 48Vdc 300W...........................................69 3 AlphaNet IDH4 for XM2........................................28 >Wireless and Fiber Backhaul 71-75 AlphaNet EDH4....................................................30 Flexible Backhaul Enclosure 2322.......................72 Continuity Software.............................................. 31 Flexible Backhaul Enclosure 2319........................73 Flexible Backhaul Enclosure 1417V......................73 >Enclosure Systems 33-49 Wireless Transport Enclosure............................... 74 MDU and Fiber Deep System..............................34 Tempest Te45 Backhaul Enclosure...................... 74 LPE Enclosure......................................................35 Tempest Te40 Backhaul Enclosure...................... 75 Node Power System............................................36 Tempest Te41 Backhaul Enclosure...................... 75 NPS Enclosure.....................................................37 PWE Enclosure.....................................................38 UPE and UPE-M Enclosures................................39 Extended Runtime Enclosures.............................40 Enclosure Accessories......................................... 41 Security Enclosure Accessories...........................42 HSHP Enclosure ..................................................43 Powernode Systems............................................44 Fibernode Power Enclosure.................................46 Surge Protection...................................................48 Precast Pads........................................................49 Pedestal Support Series......................................49 Table of Contents AlphaNet IDH4 for XM3-HP..................................29 Total Power Solutions >Complete System Solutions Systems engineered to work together are more efficient and more reliable. Alpha provides you complete systems to serve every point of your cable broadband network, as well as options for integrating renewable energy or Hybrid Power Systems into your operations. From power supplies and batteries to solar modules and turn-key buildings, our powering systems are fully integrated for maximum reliability and carefully engineered to minimize your total cost of ownership. >Installation and Construction Services With a national network of contractors, project managers and Alpha technicians, we can provide turn-key solutions for outside plant, headend, telecommunications, industrial and renewable energy applications. We work to combine your small-, medium- and large-scale projects with the necessary installation resources. Our complete installation and facility construction services include structure engineering, right-of-way and easement procurement, site preparation, equipment installation, utility hook-up coordination, system turn-up and system testing. >Preventative Maintenance An on-going Preventative Maintenance program helps ensure optimum system reliability and equipment life. Alpha's service plan options include performing routine scheduled maintenance, testing of local and remote alarm operations and analyzing local data for Outside Plant, Headend and Critical Facility Operations. >Repairs, Refurbishments and Factory Upgrades 5 Featuring an on-site CableUPS® inverter module exchange, our goal is to maintain network uptime to provide access to quick and stress-free system repairs and refurbishment options for all network and improvement of all Alpha and third-party equipment including cable power supplies, RF line gear, Headend, fiber and test equipment. >On-Site Service Alpha's state-of-the-art repair depots are strategically located across North America, and provide convenient pick-up and drop-off services. In addition to regularly scheduled driving routes, we offer preventative maintenance programs and emergency response capabilities where trained Alpha field technicians can be dispatched 24 hours a day in specially equipped and service vehicles. >Technical Support and Customer Service Communication networks are operate 24 hours a day, so we offer around-the-clock telephone technical support and web-based tools to generate RMAs and track open repairs, history and billing. >Our ISO 14001:2004 Environmental Management System Alpha strives to continually improve our Environmental Management System by benchmarking opportunities for improving our performance and demonstrating conformity to system requirements. We are committed to being industry and community leaders for sustainable business processes by meeting legal/other requirements, communicating with internal/external customers and protecting our environment through the implementation of sustainable business processes and preventing pollution from occurring through our product design and daily practices. Total Power Solutions equipment. Our repair and development laboratories are designed for product repair, refurbishment System Solutions >Fully integrated powering systems to protect your network >Next generation power solutions for emerging topologies >Power conditioning and back-up from Headend to home >Complete line of system accessories to maximize reliability, efficiency and system runtime We specialize in engineering complete network power systems committed to reliability, OpEx savings and environmental sustainability. Total Power Solutions 6 We understand that systems engineered to work together are more efficient and more reliable. As a result, we provide complete systems serving every point of the cable broadband network, as well as options for integrating renewable energy or hybrid power systems into your operations. From power supplies and batteries to solar modules and turn-key buildings, Alpha's powering systems are fully integrated for maximum reliability and carefully engineered to minimize total cost of ownership. We are proud to have served the telecommunications industry for more than 35 years, and we invite you to learn how we can strengthen your entire network with Alpha Power. High performance outside plant systems include multiple power supply, enclosure and battery options, as well as a full line of system accessories for climate-specific applications to provide extended runtimes and protect your powering investments. Our RFoG and GPON Fiber Power Systems provide the same reliability as our HFC systems with added features including outdoor access to batteries and multiple configuration options. Heavy-duty reinforced concrete equipment structures can be outfitted to your custom need, including back-up power, power conditioning, climate control, security and communications, as well as on-site calibration and preventative maintenance programs. Installation and Construction Services >Complete design, engineering, permitting, construction and commissioning >Headends, equipment shelters and other critical facilities >Turn-key installation, turn-up and test services >Grid-Tied and Off-Grid Renewable Energy Systems 7 Grid-Tied solar power can help minimize operating expenses and reduce your carbon footprint. (153kW Grid-Tied system in Phoenix, AZ) Off-Grid Solar and Hybrid Power Systems can provide the necessary redundancy for critical loads and help extend network signal to remote areas. (11kW Off-Grid Hybrid Power System in Southwest Colorado) Total Power Solutions Alpha project managers will complete all site surveys, geological testing, engineering drawings and building permit applications. Our nationwide network of contractors and project managers then coordinate the entire implementation on-site, from concept to commissioning. Preventative Maintenance >Develop historical data files for each power system component >Complete preventative maintenance checklists >Perform mechanical maintenance >Check accuracy of monitoring system readouts and alarm set points >Document routine service or call outs Alpha’s field service technicians perform routine maintenance and emergency repair services for Outside Plant, Headend and Critical Facility operations. Network hardware upgrades and critical plant hardening programs are also available. Preventative Maintenance Services An on-going Preventative Maintenance program helps ensure optimum system reliability and equipment life. Alpha’s service plan options include performing routine scheduled maintenance, testing of local and remote alarm operations and analyzing local data. Total Power Solutions 8 Preventative Maintenance >Battery expansion cabinet installation >Fixed and portable generator systems >DOCSIS transponder installation >Surge suppression & battery balancing Plant Hardening Programs With the necessary manpower and logistics to extend the life of your power networks, Alpha offers multiple plant hardening services for Outside Plant, Headend and Critical Facilities operations. 9 Total Power Solutions Repairs and Refurbishments Full Service Repair for All Broadband Equipment >40 Years experience in RF Line gear, Headend, Fiber and Test Equipment Repair >All RF Repairs are certified using a fully loaded Digital QAM Spectrum Power Supply Refurbishments and Factory Upgrades >Immediate On-site Power Supply Inverter Module Exchange >Refurbishment features include: • Replacement of all Capacitors • 2 or 3 year warranty of complete Power Supply • Implementation of engineering changes to improve reliability >Options to upgrade to embedded DOCSIS status monitoring Total Power Solutions 10 Automated test equipment is used to efficiently verify all functions of refurbished power supplies. Customer-requested and factory-recommended improvements are implemented at time of service. Refurbished equipment is put through a rigorous burn-in cycle to identify marginal components. Extensive experience repairing and refurbishing all telecommunications network equipment including Cable Power Supplies, RF Line gear, Headend, Fiber and Test Equipment. Customer Service On-site Personal Service >Free pick up and delivery on National Route Service >Reduced freight costs for best overall service Web Based Online Management Tools >Create RMA requests >Track open repairs, repair history and billing history Track all aspects of your repairs online or call one of our customer service representatives. 11 24/7 phone support available when you need it. Burnaby, British Columbia Mississauga, Ontario Bellingham, Washington Elk Grove Village, Illinois Pennsauken, New Jersey Aiken, South Carolina Phoenix, Arizona Dallas, Texas Suwanee, Georgia Jacksonville, Florida Alpha Technologies Service Depot Locations across North America offer convenient pick-up and drop-off services. Total Power Solutions Routine maintenance programs ensure system reliability. CableUPS® Power Supplies Alpha has provided specialized uninterruptible power supplies (UPS) for more than 35 years. With impressive backup power capabilities, integrated generators, dual power grid switching and enhanced battery thermal management, an Alpha CableUPS ensures reliability and efficiency in your broadband network. >XM3-HP Alpha’s XM3-HP CableUPS is the most innovative and intuitive solution to address the ever-increasing power demands of today’s sophisticated communication networks. The XM3-HP features the highest line mode and inverter efficiency with the tightest output voltage regulation, leading to decreased utility power consumption and improved overall network performance. Advanced battery management further optimizes battery life and reduces on-going operational costs by regulating current and charge. The XM3-HP features embedded DOCSIS® Communications and Alpha Applications which provide advanced intelligence diagnostics enabling remote management of the power network. >XM2-HP Alpha’s XM2-HP CableUPS is optimized to address the higher energy costs associated with running today’s cable networks. The XM2-HP features a high efficiency transformer with lower power consumption and lower life cycle costs. This “green” power supply can greatly reduce the carbon footprint of the entire cable plant by running more efficiently 24/7. Additional features include an enhanced Smart Display with improved menus and a dedicated Communications menu with DOCSIS parameters. The XM2-HP is available in three convenient power ratings for load matching to operate at optimal efficiency. 13 >XM2 it an ideal match for network architectures worldwide. Advanced product design features include a hot-swappable modular inverter and Smart Display. Optional independent dual outputs and N+1 redundant capability provide additional protection and enhanced system reliability. AC or DC generator compatibility, flexible system control and advanced status monitoring options support easy migration to clustered or centralized powering. >XM2-300HP The XM2-300HP is the ideal CableUPS solution for rapidly expanding cable broadband networks and services. When used in applications requiring less power than traditional outside plant powering, you will experience increased efficiency and reduced operating costs. This 300 Watt power system features a much smaller footprint and is engineered for use in multiple dwelling units (MDU), business parks and node segmentations, as well as Fiber Deep, N+0 and N+1 plant extensions. Rated at 300 Watts, with a 12V inverter, this power supply features an XM2 Smart Display and an optional DOCSIS-based status monitoring card. >APX Alpha’s APX is designed for communication networks that require compact, non-standby power supplies. The APX’s ferroresonant design provides fully regulated output voltage, surge and short-circuit protection. The APX can be easily upgraded by adding modular plug-in options such as a Lightning Arrestor, Time Delay Relay, Ammeter, Status Indicator LED or AmpClamp™ Surge Suppressor. >APP The APP is a portable non-standby power supply used to provide conditioned AC power to the load when the main power supply is being serviced. Used in conjunction with the "Alternate" connector and the "ALT/ON" switch located on the enclosure's service power inserter, power can be transferred from the main power module to the APP without interrupting the connected load. Cable Power Supplies Alpha’s XM2 CableUPS is the industry’s leading power technology. A variety of power ratings make XM3-HP CableUPS® Power Supply Advanced Efficiency Technology The Alpha XM3-HP triple efficiency ferro technology optimizes the power supply’s performance resulting in significantly reduced utility power consumption and a direct savings in network operating costs. Exclusive, Patent-Protected Transformer Design. > Highest Line Mode Efficiency The XM3-HP offers the highest line mode efficiency available, requiring less AC utility power to support a load. Utility Power = (kW) Cable Power Supplies 14 ( P Network Load Cable Power Loss—I2R + ∑ [( P @ Active V @ Active 2 ) X Ω Feet of cable X Feet ] Distance Power Supply Efficiency > Tightest Output Voltage Regulation Alpha’s XM3-HP provides the tightest output voltage regulation ever offered to reduce I2R cable power losses. > Maximum Inverter Efficiency Significant gains in inverter efficiency directly translates into increased battery runtimes, further improving network performance and power outage recovery capabilities. Available Models Load Optimization: The XM3-HP is available in 8, 10, 15 and 18 Amp models to best match network load requirements. ALPHA XM3-908HP Guide for Optimal Efficiency ALPHA XM3-910HP ALPHA XM3-915HP ALPHA XM3-918HP 0 2 4 6 8 10 AMPS 12 14 16 18 Maximum Efficiency ) XM3-HP CableUPS® Power Supply Advanced Battery Management The Alpha XM3-HP’s advanced battery management optimizes battery life and contributes to both reducing capital expenditures and on-going operating costs. Embedded Battery Balancing 12.66Vdc 1200mA 1300mA 2500mA > 14.00Vdc 13.87Vdc The Alpha XM3-HP supports the embedded AlphaGuard uses advanced battery balancing technology to re-direct current Optimal Float Voltage is 13.62Vdc at 25°C / 77°F from overcharged batteries to the undercharged battery, optimizing battery service life. - Battery Charger 40.86Vdc Float Voltage AlphaGuard — Balancing 14.00Vdc AlphaGuard — Balanced 1200mA 1300mA 2500mA 12.66Vdc + 13.87Vdc + 13.62Vdc 13.62Vdc 13.62Vdc 40.86Vdc Float Voltage 300mA > 300mA 300mA 300mA 13.62Vdc 13.62Vdc Dynamic Multi-Stage Charging The Alpha XM3-HP's dynamic 5-stage battery charging technology 13.62Vdc provides system batteries with optimal charge management. Batteries are balanced within ±0.1Vdc and the Float current across each battery is equal. 13.62Vdc Float @ 25°C / 77°F - Battery Charger + Refresh • Bulk • Accept • Float • Rest 40.86Vdc Float Voltage > Advanced AlphaCell® Battery Technology Extended Runtime The XM3-HP’s advanced battery management and increased inverter efficiency maximizes battery runtime in the network. XM3 AlphaCell® Typical Runtime (minutes) 6A 15 Cable Power Supplies Battery Charger 40.86Vdc Float Voltage 300mA Batteries are balanced within ±0.1Vdc and the Float current across each battery is equal. 13.62Vdc Float @ 25°C / 77°F - Battery Charger + Optimal Float Voltage is 13.62Vdc at 25°C / 77°F - 300mA 90Vac @ 4A Model: 3.5HP 4.0HP 3.5HP 4.0HP 3.5HP 8A 4.0HP 3.5HP 10A 4.0HP 3.5HP 12A 4.0HP 3.5HP 14A 4.0HP 3.5HP 16A 3 Batteries: 540 588 358 394 263 295 204 234 165 193 137 164 116 142 6 Batteries: 1144 1264 771 841 574 624 450 491 368 404 308 342 264 295 Model: 195GXL 220GXL 195GXL 220GXL 195GXL 220GXL 195GXL 220GXL 195GXL 220GXL 195GXL 220GXL 195GXL 220GXL 3 Batteries: 476 550 313 363 229 265 177 205 142 164 118 136 99 115 6 Batteries: 1026 1177 685 789 506 585 396 458 322 373 269 311 229 266 4.0HP XM3-HP CableUPS® Power Supply Advanced Intelligence Platform The Alpha XM3-HP's internal intelligence provides Network Operation Centers (NOC) with the critical and highly relevant data necessary to reduce operating expenses through remote management of the power network. > Embedded DOCSIS® Communications. The XM3's AlphaNet™ Integrated DOCSIS Communications Platform enables access to all of the XM3's advanced information and diagnostics through a standard (SNMP) network interface. DOCSIS® Communications Menu COMM – GENERAL CM MAC ADDRESS COMM – GENERAL CM IP ADDRESS h 16 i COMM – GENERAL CM RECEIVE POWER 192.168.1.120 00:90:EA:00:36:EA h ESC MAC Address i COMM – GENERAL CM TRANSMIT POWER 9.8dBmV ESC h i IP Address 39.0dBmV h ESC i ESC Receive and Transmit Power Levels > > 3 Hours Embedded Alpha Applications. 2-3 Hours 1-2 hrs < 1 Hr Calculating Not Available Power reliability algorithms use real-time data to predict service intervals and battery replacements. Enter Battery Date Code & MHOs Reading BATT A1 hi DATE Battery Health Battery Remaining Runtime Battery Expected Life Network Power Backup Capacity 1/10 ENTR h i ESC 2-3 Hours 1-2 hrs < 1 Hr Calculating Not Available Battery Expected Life Utility Performance Reports Battery MHOs Trending Utility Performance Reports Total Power Supplies = 1600 • North American MSO 4.0% > 3 Hours < 1 Year 1-2 Years 2-3 Years 3-5 Years > 5 Years Adjust Value ENTR to shift field Site #028A1B1 Historical Conductance Analysis Report AlphaCell 195GXL < 1 Year 1-2 Years 2-3 Years 3-5 Years > 5 Years 1400 3.5% Freq Shifts 2.5% Surges 1200 Sags Battery A1 Battery A2 Battery A3 1000 Healthy 3.0% Outages 1.6% 600 1.0% 400 0.5% 200 0.0% January February March April May June 0 PM Recommended 800 Replace 2.0% MHOs Precent of Power Supplies Affected Cable Power Supplies Network Power Backup Capacity 2012 2013 2014 2015 2016 2017 2018 XM3-HP CableUPS® Power Supply >Improved efficiency levels >Optimized network performance >Reduced operating costs and total cost of ownership XM3-HP CableUPS XM3-HP Models 908HP 910HP 915HP 918HP Nominal AC Input Voltage: 120Vac 120Vac 120Vac, 240Vac 120Vac Nominal Input Frequency: 60Hz 60Hz 60Hz 60Hz Input Frequency Tolerance (%): ±3 ±3 ±3 ±3 Input Voltage Operating Range Tolerance (%): -25 / +15 -25 / +15 -25 / +15 -25 / +15 Input Voltage Range (Vac): 90-138 90-138 90-138, 173-276 90-138 Output Voltage (Vac): 63 / 89 63 / 89 63 / 89 63 / 89 Output Voltage Regulation (%): -2.5 / +1 -2.5 / +1 -2.5 / +1 -2.5 / +1 Maximum Rated Output Current: 8 Amps 10 Amps 15 Amps 18 Amps Maximum Output Power (VA): 720 900 1350 1620 Fine Mode Parameters Standby Efficiency: Up to 91% Output Waveform: Quasi-square wave <150% of maximum current rating Short Circuit Protection: Uninterrupted output Transfer Characteristics: Battery Voltage (Vdc): 36 36 36 36 Battery Charger Programmable (0 to 5mV/Cell/ºC) Temperature Compensation: 10A Bulk Charger Current: Refresh, Bulk, Accept, Float, Rest 5 Stages: Mechanical Front plug in, Hot swappable inverter module Inverter Module: Dimensions H x W x D (in/mm): Weight (lb/kg): Input Power Connector (IEC 320/C20): Battery Connector: Remote Temp Sensor: Display: 7.8 x 15 (16.7 w/handle) x 10 (10.7 w/handle) / 198.1 x 381 (424.18 w/handle) x 254 (271.8 w/handle) 48.5 / 22.0 NEMA 5-15P Plug 49 / 22.3 60 / 27.2 60.5 / 27.5 NEMA 5-15P Plug NEMA 5-20P/ NEMA 6-15P Plug NEMA 5-20P Plug Anderson style 75A Ring lug fastens to negative terminal on center battery 4 line by 20 character blue LCD with soft-key menu controls Environment Operating Temperature: Humidity: -40 to 60°C / -40 to 140°F (derate by 2ºC / 3.6°F per 1000 feet above 3000 feet) 0 to 95% non-condensing (relative) Agency Compliance Safety: EMC: CSA/UL 60950-1 (2nd), UL 1778 (4th) CSA No 107.3, C/US FCC Part 15 Class A Cable Power Supplies Up to 94% Line Mode Efficiency: 17 XM2-HP CableUPS® Power Supply >High efficiency transformer >Features Intelligent Inverter Module >6, 18 and 24A models available >Backwards compatible with XM2 CableUPS® >Embedded and External DOCSIS® status monitoring XM2-HP CableUPS >Up to 15% more capacity than standard models XM2-HP Models XM2-906HP XM2-918HP XM2-924HP Input Voltage (Vac): 120/240 120/240 208/240 Input Voltage Window: -30 to +20% -20 to +15% -20 to +15% Input Frequency: 60Hz 60Hz 60Hz Input Frequency Window: ±3Hz ±3Hz ±3Hz Output Voltage (Vac): 63/87 63/75/87 63/75/87 Output Current (A): 8/6 22/18/18 22/22/24 Max Output Power (VA): 540 1620 Electrical 18 Voltage Regulation1: Cable Power Supplies 2160 Quasi-square wave Output Waveform: Output Frequency Stability: ±5% ±5% ±5% Line Mode 60Hz Nominal Inverter Mode 60Hz, ±0.05% <150% of maximum current rating Short Circuit Protection: Uninterrupted output Transfer Characteristics: Battery Voltage (Vdc): 36 36 48 Efficiency (Typical Load Range) Line Mode: 80-87% 90-92% Standby Mode: 79-84% 84-86% Battery Charger Programmable (0 to 5mV/Cell/°C) Temperature Compensation: 10A at 80% load and nominal input (bulk charge mode) Charger Current: Bulk, Accept, Float Three Stage: Mechanical Status Display: 2 x 20 Blue LCD with backlight Dimensions H x W x D (in/mm): 8.8 x 15 x 13 / 222 x 381 x 330 Approx. Weight (lb/kg): 53 / 24 Finish: 72 / 32.7 95 / 42.9 Black, epoxy powdercoat Environment Operating Temperature: Humidity: Agency Compliance: -40 to 55°C / -40 to 131°F 0 to 95% non-condensing FCC Part 15 Class A, UL1778, CSA 22.2 No. 107.1 Optional Features Standard Protective Interface Module (PIM/N+1): Provides two programmable outputs from a single XM2 CableUPS power supply for redundancy in critical applications. The PIM protects system components and provides isolation between distribution legs by shutting down the individual load during over-current conditions. Note: 1 Voltage regulation is maintained over both line and load ranges XM2 CableUPS® Power Supply >Proven CableUPS® uninterruptible power supply >Features Intelligent Inverter Module >10, 15 and 22A models available >Modular design with hot-swappable inverter >Programmable, temperature-compensated battery charger XM2 CableUPS >Embedded and External DOCSIS status monitoring ® XM2 Models XM2-910 XM2-1350-48 XM2-915 XM2-915HV XM2-922 XM2-922HV Input Voltage (Vac): 120/240 120/240 120/240 120/240 208/240 240 Input Voltage Window: -20 to +15% -20 to +15% -20 to +15% -30 to +15% -20 to +15% -30 to +15% Input Frequency: 60Hz 60Hz 60Hz 60Hz 60Hz 60Hz Input Frequency Window: ±3Hz ±3Hz ±3Hz ±3Hz ±3Hz ±3Hz Output Voltage (Vac): 63/75/87 63/75/87 63/75/87 63/75/89 63/75/87 63/75/89 Output Current (A): 10/10/10 22/15/15 15/15/15 20/17.5/15 22/22/22 22/22/22 Max Output Power (VA): 900 1350 1350 1350 2025 2025 ±5% ±5% 48 48 Electrical Quasi-square wave Output Waveform: Voltage Regulation: ±5% ±5% ±5% ±5% Line Mode 60Hz Nominal Inverter Mode 60Hz, ±0.05% <150% of maximum current rating Short Circuit Current: Uninterrupted output Transfer Characteristics: Battery Voltage (Vdc): 36 48 36 36 Efficiency (Typical Load Range) Line Mode: 86-90% Standby Mode: 82-85% Battery Charger Programmable (0 to 5mV/Cell/°C) Temperature Compensation: 10A at 80% load and nominal input (bulk charge mode) Charger Current: Bulk, Accept, Float Three Stage: Mechanical Status Display: 2 x 20 Blue LCD with backlight Dimensions H x W x D (in/mm): 8.8 x 15 x 13 / 222 x 381 x 330 Approx. Weight (lb/kg): 62 / 28.1 Finish: 70 / 31.8 70 / 31.8 72 / 32.7 92 / 41.7 96 / 43.5 Black, epoxy powdercoat Environment Operating Temperature: Humidity: Agency Compliance: -40 to 55°C / -40 to 131°F 0 to 95% non-condensing FCC Part 15 Class A, UL1778, CSA 22.2 No. 107.1 Optional Features Standard Protective Interface Module (PIM/N+1): Provides two programmable outputs from a single XM2 CableUPS power supply for redundancy in critical applications. The PIM protects system components and provides isolation between distribution legs by shutting down the individual load during over-current conditions. Note: 1 Voltage regulation is maintained over both line and load ranges Cable Power Supplies Output Frequency Stability: 19 XM2-300HP High Efficiency CableUPS® >High efficiency 300W power supply >XM2 programmable LCD Smart Display >New predictive preventative maintenance features >Small footprint and lightweight >Ideal for RFoG, MDU and N+0 applications >Embedded DOCSIS® status monitoring XM2-300HP CableUPS XM2-300HP Model XM2-300HP Electrical Cable Power Supplies 20 Input Voltage (Vac): 120 Input Voltage Window: -15 to +10% Input Frequency: 60Hz Input Frequency Window: ±3Hz Output Voltage (Vac): 60/87 Output Current (A): 5/3.5 Max Output Power (VA): 300 Output Waveform: Sine wave Voltage Regulation: ±5% Output Frequency Stability: Line Mode 60Hz Nominal Inverter Mode 60Hz, ±0.05% Short Circuit Protection: 150% for 10 seconds Transfer Characteristics: ≤4ms Battery Voltage (Vdc): 12 Efficiency (Typical Load Range) Line Mode: 93-94% Standby Mode: 82-86% Battery Charger Temperature Compensation: Programmable (0 to 5mV/Cell/°C) Charger Current: 6A minimum - 10A maximum Three Stage: Bulk/Accept/Float Mechanical Status Display: Blue smart display 2 x 20 LCD with backlight Dimensions H x W x D (in/mm): 8.5 x 9.75 x 8 / 216 x 248 x 203 Approx. Weight (lb/kg): 23 / 10.4 Finish: Black, epoxy powdercoat Environment Operating Temperature: -40 to 55°C / -40 to 131°F Humidity: 0 to 95% non-condensing Agency Compliance: FCC Part 15 Class A, UL / CSA 60950-1, UL1778, UL1012 CSA C22.2 No. 107 Advanced Diagnostics Advanced Analytics: Onboard battery algorithm for predictive service required, Onboard inverter algorithm for predictive service required User Inputs: Power supply install and battery manufacturing dates, Power supply priority level, Siemens values during battery preventative maintenance cycles, Battery out-of-date period, Battery heater mat installed (Yes/No), Technician code/ID APB APB HFC Voltage Booster >Configurable for 90 or 60Vac output voltage >High-efficiency auto transformation >Intelligent overload protection >Water-tight enclosure; wall or standard mounted >Reverse connection protection >Input surge protection >Automatic bypass in the event of downstream network failure Alpha Power Booster APB Specifications Mechanical Electrical Dimensions H x L x D (in/mm): 9.13 x 14 x 6.75 / 232 x 356 x 171 Input Voltage: 45 to 65Vac 60Hz / 65 to 90Vac 60Hz Weight (lb/kg): 21.4 / 9.7 Input Current: 10 Amps RMS (max.) Environmental Output Voltage: 36Vac 60Hz / 87Vac 60Hz Output Current: <8 Amps RMS (max.) Output Rating: Operating Temperature: -40 to 65°C / -40 to 149°F Storage Temperature: -50 to 70°C / -58 to 158°F 650VA (max.) Outdoor Rating: Type 4 enclosure Overload Protections*: 115% of max input current for 27 minutes* Standard Compliance Short Curcuit: Bypass mode, automatic recovery Overload Recovery: Automatic Surge Resistance: 6kV / 3000A (IEEE C61.45 part 15) Efficiency: >96% at 25 to 100% load RF Freq Range: 5 to 1000MHz RF Insertion Loss Maximum: 1.2dB (5 to 50MHz), 1.2dB (50 to 870MHz), 1.6dB (870 to 1000MHz) Flatness: ±0.25dB (5 to 50MHz), ±0.35dB (50 to 870MHz), ±0.50dB (870 to 1000MHz) RF Slope Maximum: 0.80dB (5 to 50MHz), -1.0dB (50 to 870MHz), -1.25dB (870 to 1000MHz) Hum Modulation: <-68dB (5 to 1000MHz), (<-82dB freq. domain) Return Loss Minimum: 17dB (5 to 1000MHz) Electrical Egress: <-120dBm (45 to 870MHz) Isolation: Neutral carries through Safety: CSA (C/US) CAN/CSA C22.2 No. 60950-1-07 UL 60950-1, 2nd Edition Note: * The APB is designed to open up an output relay and discontinue output during extended periods of overload to protect vital components. Once this relay is open, the unit will periodically attempt to close the relay to determine if the overload condition has ceased. Dual Inverter Module Case >Durable and lightweight case >Antistatic cushioning to protect Inverter Modules >Fits any combination of XM2 I2M or XM3 Inverters >Discounted pricing when purchasing case with Inverter Modules >Extra space to store spare components Smart Pack Mechanical 9.6 x 21.3 x 14.3 / 243 x 541 x 363 Weight (lbs/kg): Empty IM Case: 6.2 / 2.8 Case with Two I M: 20.8 / 9.5 2 Case with Two IM3: 17.4 / 7.9 Case with I2M and IM3: 19.2 / 8.7 Smart Pack Case 1: Spare component case, 2: Status monitors Cable Power Supplies High-efficiency autotransformer Intelligent overload protection Water-tight enclosure; wall or strand mounted LED function indicator light on PCB for troubleshooting Smart Pack Dimensions H x L x D (in/mm): 21 Standard Features APX Non-Standby Power Supply >Complete line conditioning >Modular transformer design >Flexible mounting options >Current limited output and short circuit protection APX Series APX Models: 22 Input Voltage (Vac) Input Frequency (Hz) Output Voltage (Vac) Output Current (A) Max. Output Power (VA) Input Protection (breaker) Output Protection (fuse) Weight (lb/kg) APX 6008: 120 60 63 8 480 8A 10A 21 / 9.5 APX 6014: 120 60 63 14 840 12A 15A 30 / 13.6 APX 9015-120: 120 60 63/75/87 15 1350 12A 20A 47.5 / 21.6 APX 9015-240: 240 60 63/75/87 15 1350 12A 20A 47.5 / 21.6 APX 9015-120 HV: 120 60 63/75/89 15 1350 12A 20A 51 / 23 APX 9015-240 HV: 240 60 63/75/89 15 1350 12A 20A 51 / 23 APX 6008 RM: 120 60 63 8 480 8A 10A 22 / 10 APX 6014 RM: 120 60 63 14 840 12A 15A 31 / 14 Note: Other voltages and configurations may be available. For more information, contact your local Alpha sales representative. Cable Power Supplies Input Mounting Options Power Factor: >0.90 at full load Voltage Tolerance: ±15% Voltage (APX 9015 HV): -25 to 15% Frequency: ±3% Output Waveform: Quasi-square wave Regulation: ±5% Efficiency: 90% or better Pole Mount (PM): Built of durable, weather-resistant, powdercoated aluminum to withstand the harshest environments. This enclosure also includes brackets that provide for easy bolted, or banded Pole Mounting. Wall Mount (WM): Allows the module to be mounted on a flat, vertical surface. Shelf Mount (SM): Allows the module to be mounted on flat, horizontal surfaces such as the PWE or UPE enclosures. An extended input power cable is also included. Pedestal Mount (PED): Ideal for ground mount applications, and provides weather-resistant, steel construction. The APX PED is available in either concrete or soil mount versions (please specify at time of order). Rack Mount (RM): Ideal for mounting the power supply in a standard 19" rack. Mechanical Dimensions H x W x D (in/mm) APX 6008, 6014: 11.75 x 7.5 x 10.5 / 298 x 190 x 267 APX 9015: 15.5 x 8.5 x 11 / 394 x 216 x 279 Finish: Gray, epoxy powdercoat Enclosure Material: Aluminum Environment Operating Temperature: -40 to 55°C / -40 to 131°F Agency Compliance: UL1012/CSA C22.2 No. 107.1-M95 Optional Features SIL-C: Long life LED pilot light LA-M: Plug-In lightning arrestor (120V) AMM-C: Easy reading panel ammeter TDR-M: Time delay relay (10 to 60sec variable) ACAT-3P: Plug-In Amp Clamp™ GLK: Enclosure security lock (PM) APX - Cover removed APP Service Power Supply >Portable service power supply >Time proven ferroresonant technology >Selectable input and output voltages >15A and 22A versions available APP9022S APP APP9015S APP9022S Input Voltage (Vac): 120/240 ±15% 120/240 ±15% Input Current (A): 12 16/12 max. Input Frequency: 60Hz 60Hz Output Voltage (Vac): 60/75/87 ±5% 60/75/87 ±5% Output Current (A): 15 17 (22 at 240Vac Input) Output Power (VA) (Continuous): 1350 1350/1650/2000 Output Current Limit: 150% of output rating 150% of output rating Efficiency: 90% typical @ rated load 90% typical @ rated load Agency Compliance: — CSA Finish: Black, epoxy powdercoat Black, epoxy powdercoat Operating Temperature: -40 to 50°C / -40 to 122°F -40 to 50°C / -40 to 122°F Dimensions H x W x D (in/mm): 9 x 9.5 x 13.75 / 229 x 241 x 349 9 x 9.5 x 14.75 / 229 x 241 x 375 Weight (lb/kg): 47 / 21 60 / 27 23 Cable Power Supplies Models: APP Kits: APP-9015S Kit Includes: 874-726-20 — Line Cord Assy, 120Vac, 5-20P, APP-9015S 874-727-20 — Line Cord Assy, 240Vac, 6-15P, APP-9015S 874-728-20 — Output Cable Assy, Jones Connector, APP-9015S 874-712-20 — WR KT, ADPTR, SPS JONES to SPI 25XM APP-9022S Kit Includes: 874-935-20 — Line Cord Assy, 120Vac, 5-20P, APP-9022S 874-935-21 — Line Cord Assy, 240Vac, 6-15P, APP-9022S All output cables for the APP-9022S are to be ordered as separate line items. One standard output cable kit (745-223-20) is included in the price of the APP-9022S. Additional output cables or 30ft cable kits can be ordered (additional cost) as needed. 745-223-20 Kit Includes: 874-949-20 — Y-Cables, 25A Connectors, 6', APP-9022S 874-949-21 — Y-Cables, Jones, 6', APP-9022S 875-173-20 — Lectro Adapter, Lectro to APP-9022S Cables: 874-726-20 (5-20 plug) Power cord with 5-20P plug (120Vac) 874-727-20 (6-15 plug) Power cord with 6-15P plug (240Vac) 874-728-20 Output cable, single Jones 875-173-20 25A Lectro Adapter 874-935-20 (5-20 plug) Power cord with 5-50P plug (120Vac) 874-935-21 (6-15 plug) Power cord with 6-15P plug (240Vac) 874-935-22 Optional 10-Ft cord with 30A connector and Twist Lock Plug (125Vac) 874-949-20 Y cable with 25A connectors 874-949-21 Y cable with Jones connectors 874-949-32 30-Ft cable 874-949-33 Y cable adapter for 25A connector 874-949-34 Y cable adaptor for Jones connector Status Monitoring Monitoring, measuring and managing power supplies, batteries and generators are not easy tasks. However, in order to maintain customer satisfaction, reduce operating costs and meet regulatory requirements, you need specific information from your systems. Alpha’s status monitoring solutions use state-of-the-art communications technology to transmit critical network performance data to the headend or network management center. This allows you to be proactive and take corrective action before serious problems occur. Whether you are extending the life of your network backup power through battery balancing, managing QoS for VoIP services or monitoring for trouble areas during an AC power outage, the AlphaNet™ series of products provides the tools to manage today’s network power requirements with the ability to upgrade for tomorrow’s needs. >AlphaNet DSM Series The AlphaNet family of networking products, including the 3rd generation DOCSIS® Status Monitoring broadband power communication card, enables Alpha’s XM3-HP, XM2-HP, XM2, XM2-300HP and GMX CableUPS® to connect directly to an HFC network through an embedded DOCSIS cable modem. Through a Simple Network Management Protocol (SNMP) interface, standard MIBs are used for quick, efficient network status and diagnostics. A Web interface enables any authorized personnel direct access to powerful, advanced diagnostics using a common web browser. No proprietary software is required. A single DSM installed in an Alpha CableUPS supports communications and system control for multiple Alpha power supplies and an AlphaGen™ generator system. >AlphaNet IDH Series 25 Alpha's IDH transponders from Cheetah Technologies combine the latest monitoring capabilities with advanced features available through the Cheetah XD management platform. Alpha's EDH4 by Cheetah Technologies enables legacy power supplies to be monitored using the latest DOCSIS transponders. >Continuity DOCSIS Power Supply Monitoring Continuity-SPS (Standby Power Supply) is a flexible standby power supply status monitoring solution. Based on HMS and DOCSIS standards, Continuity supports any standards-based transponder, providing you with a centralized, feature-rich, web-enabled tool to monitor all the standby power supplies in your network. Status Monitoring >AlphaNet External Transponders AlphaNet™ DSM3 Family DOCSIS® Status Monitor for XM2 Family, GMX and VMX >Embedded network management for Alpha broadband power supplies >Battery and power supply advanced diagnostics reduces truck rolls and overall operating expense of maintaining a network AlphaNet DSM3 >Three models available: DSM3 (standard), DSM3x (advanced) and DPM (XM2-300HP) AlphaNet DSM3x AlphaNet DPM AlphaNet DSM3 Family for XM2 Family, GMX and VMX Power Supply Monitored Parameters Specifications 26 Power Supply Models Supported: DSM3x and DSM3: XM2-HP, XM2-300HP, XM2, GMX, VMX DPM: XM2-300HP Major Alarm: Battery Monitoring: DSM3x: Up to four strings of 36 or 48V batteries, DSM3: Up to two strings of 36 or 48V batteries, DPM: One 12V battery Minor Alarm: Power System Management (DSM3x Only): Up to five power supplies and an AlphaGen generator are managed from a single DSM3x including coordinated battery charging, system test and aggregated alarm Management Protocol: Standard ANSI/SCTE HMS MIBs support basic power supply monitoring. Advanced diagnostics with battery and power module analytics available via secure SNMP Advanced Diagnostics Status Monitoring Intelligent Power Supply Interface: Power supply user interface displays advanced diagnostics including: DOCSIS modem upstream and downstream RF levels, IP address assigned by network DHCP server, MAC address and firmware levels, individual battery voltages to verify correct wire harness installation Hardware Aggregate alarm consisting of: test fail, battery fail, line isolation alarm, output overload, inverter, over-temperature, N+1 active, fuse fail Aggregate alarm consisting of: temperature probe error, AC line loss, N+1 error Input Voltage: Reported from power supply V(in) measurement Output Voltage: Reported from power supply V(out) measurement Output Current: DSM3x and DSM3: 0 to 25A standard on port 1. Ports 2-4 require power supply option. DPM: Dual outputs do not exceed 300 Watts combined 3.5 Amps at 90 Vac output voltage, 5 Amps at 60 Vac output voltage Output Power: Calculated, reported in AC Watts UPS Status: AC Line, Standby, Test in process, Test alarm Enclosure Door: Open or Closed Battery Voltage: DSM3x: Individual battery voltage, up to four strings of 3 or 4 batteries (maximum 16 batteries), ±100mV per battery. DSM3: Individual battery voltage, up to two strings of 3 or 4 batteries (maximum 8 batteries), ±100mV per battery. DPM: Individual battery voltage Battery Temperature: Reported from power supply battery Remote Temperature Sensor (RTS) Remote Test Control: Start/Stop power supply test cycle RF Cable Interface: F-connector, female, 75 Ohm, connector angle accommodates coax bend radius when installed in some enclosures Local Interface: RJ-45, Ethernet, multi-mode operation Generator Monitored Parameters (DSM3x Only) LED Indicators: Ready/Alarm, Upstream registration, Downstream lock, AlphaBus, RF level, Link, CPE traffic, Battery harness correct Status: Generator Off, Running, Alarm I/O Control (DSM3x Only): 6-pin Molex: Digital input, Digital output, 5V, Common Generator Alarm: AlphaBus: RJ-11 offset tab: Multi-power supply and AlphaGen communications Aggregate alarm consisting of: low oil pressure, engine overtemp, engine over-speed, crank limit, over voltage, low fuel, water intrusion, pad shear, gas hazard, test fail Gas Hazard: OK, Alarm Battery Monitoring: DSM3x: 8-pin Molex battery string A/B, 8-pin Molex battery string C/D. DSM3: 8-pin Molex battery string A/B Water Intrusion: OK, Alarm Pad Shear: OK, Alarm Tamper: NO or NC, software configurable, reads enclosure door magnetic switch Enclosure Door: Open, Alarm Ignition Battery Voltage: ±100mV Enclosure Temperature: ±2°C Environment Operating Temperature: -40 to 65°C / -40 to 149°F Low Fuel: OK, Alarm Storage Temperature: -40 to 85°C / -40 to 185°F Remote Test Control: Start / Stop generator test cycle Humidity: 10 to 90% non-condensing Cable Modem Compliance: DOCSIS 1.1 and 2.0 EuroDOCSIS 2.0 Transmit Frequency Range: 5 to 42Mhz 5 to 65Mhz Regulatory Compliance: FCC Part 15 Class A EN 50083-2:2006 EMC requirements for CATV equipment EN 62040-2:2006 Uninterruptible power supply EMC requirements, Category C2 Surge: IEEE 587, Category B3 RoHS: Directive 2002/95/EC Receive Center Frequency Range: 91 to 857Mhz 112 to 858Mhz Output Power Range: TDMA: +8 to +54dBmV (32QAM, 64QAM) +8 to +55dBmV (8QAM, 16QAM) +8 to +58dBmV (QPSK) S-CDMA: +8 to +53dBmV (All modulations of S-CDMA) TDMA: +68 to +114dBuV (32QAM, 64QAM) +68 to +115dBuV (8QAM, 16QAM) +68 to +118dBuV (QPSK) S-CDMA: +68 to +113dBuV (All modulations of S-CDMA) Input Signal Range: -15 to 15dBmV 64QAM: 43 to 73dBuV 256QAM: 47 to 77dBuV Channel Bandwidth: 6Mhz 8Mhz Network Communications DOCSIS (RF) Port Protocols: IP, UDP, TCP, DHCP, TFTP, SNMPv1, SNMPv2c, HTTP Ethernet Port: Local Mode: HTTP web interface for local on-site diagnosis CPE Mode: DOCSIS Cable modem Ethernet CPE functionality MIBs: Power supply (ANSI/SCTE 38-4) Other SCTE HMS MIBs as defined by the SCTE for power supply and generator status monitoring Alpha proprietary advanced UPS diagnostics Additional Equipment XP-BSC-3-6: Wire Kit, Battery Sense, 1x36V, 6' XP-BSC-6-6: Wire Kit, Battery Sense, 2x36V, 6' XP-BSC-4-6: Wire Kit, Battery Sense, 1x48V, 6' Surge Arrestor (Alpha P/N 162-028-10): Female/Female connector configuration, "F"-type connector with integral ground block required for all installations AlphaNet™ DSM3 Family DOCSIS ® Status Monitor for XM3-HP Series >Embedded network management for Alpha broadband power supplies >Three models available: DSM3 (standard), DSM3x (advanced) and DPM (used with Smart AlphaGuard option) AlphaNet DSM3 AlphaNet DSM3x AlphaNet DPM AlphaNet DSM3 Family for XM3-HP Series Power Supply Monitored Parameters Specifications Power Supply Models Supported: DSM3, DSM3x and DPM: XM3-HP Series Major Alarm: Battery Monitoring: DSM3: Up to two strings of 36V batteries, DSM3x: Up to four strings of 36V batteries, DPM: Up to four strings of 36V batteries with Smart AlphaGuard Option (SAG) Aggregate alarm consisting of: test fail, battery fail, line isolation, output failure, output overload, output tripped, charger failure, inverter temperature, configuration error, inverter failure, no batteries, battery failure Power System Management (DSM3x Only): Up to five power supplies and an AlphaGen generator are managed from a single DSM3x including coordinated battery charging, system test and aggregated alarm Minor Alarm: Aggregate alarm consisting of: AC line loss, input over current/ input current limit, surge MOV failure, inverter enable, option board failure, battery temperature probe Input Voltage: Reported from power supply V(in) measurement Output Voltage: Reported from power supply V(out) measurement Management Protocol: Standard ANSI/SCTE HMS MIBs support basic power supply monitoring. Advanced diagnostics with battery and power module analytics available via secure SNMP Output Current: 0 to 25A standard on port 1, port 2 requires power supply option Output Power: Calculated, reported in AC Watts Input Current: Reported in Amps Input Power: Reported in AC Watts UPS Status: AC Line, Standby, Test in process, Test alarm Charger Current: Reported in Amps Battery Discharge Current: Reported in Amps Battery Voltage: DSM3x: Individual battery voltage, up to two strings of 3 or 4 batteries (maximum 8 batteries), ±100mV per battery. DSM3: Individual battery voltage, up to four strings of 3 or 4 batteries (maximum 16 batteries), ±100mV per battery. DPM: Individual battery voltage, up to two strings of 3 or 4 batteries (maximum 8 batteries), ±100mV per battery. Requires SAG option Battery Temperature: Reported from power supply battery Remote Temperature Sensor (RTS) Remote Test Control: Start/Stop power supply test cycle Enclosure Door: Open or Closed Advanced Diagnostics Intelligent Power Supply Interface: Power supply user interface displays advanced diagnostics including: DOCSIS modem upstream and downstream RF levels, IP address assigned by network DHCP server, MAC address and firmware levels Power supply internal analytic dignostics report when batteries should be serviced. • Battery String Runtime Remaining • Battery Life Remaining Utility Status and Events (Requires AlphaApps Option): AC Line Status: • Utility Performance Status (outages, sags, surges, frequency) • Utility Events (24-hour and lifetime number of events) History Log Reports: • Power Supply Event Log (events of daily power supply operation) • Power Supply Configuration Log (events that occur infrequently) • Battery Event Log (battery conductance measurements and battery manufactured dates) Hardware Generator Monitored Parameters (DSM3x Only) Status: Generator Off, Running, Alarm Generator Alarm: Aggregate alarm consisting of: low oil pressure, engine overtemp, engine over-speed, crank limit, over voltage, low fuel, water intrusion, pad shear, gas hazard, test fail RF Cable Interface: F-connector, female, 75 Ohm, connector angle accommodates coax bend radius when installed in some enclosures Gas Hazard: OK, Alarm Local Interface: RJ-45, Ethernet, multi-mode operation Water Intrusion: OK, Alarm LED Indicators: Ready/Alarm, Upstream registration, Downstream lock, AlphaBus, RF level, Link, CPE traffic, Battery harness correct Pad Shear: OK, Alarm Enclosure Door: Open, Alarm I/O Control (DSM3x Only): 6-pin Molex: Digital input, Digital output, 5V, Common Ignition Battery Voltage: ±100mV AlphaBus: RJ-11 offset tab: Multi-power supply and AlphaGen communications Enclosure Temperature: ±2°C DSM3x: 8-pin Molex battery string A/B, DSM3: 8-pin Molex battery string A/B and 8-pin Molex battery string C/D Low Fuel: OK, Alarm Remote Test Control: Start / Stop generator test cycle Battery Monitoring: Tamper: NO or NC, software configurable, reads enclosure door magnetic switch Environment Operating Temperature: -40 to 65°C / -40 to 149°F Storage Temperature: -40 to 85°C / -40 to 185°F Humidity: 10 to 90% non-condensing Regulatory Compliance: FCC Part 15 Class A EN 50083-2:2006 EMC requirements for CATV equipment EN 62040-2:2006 Uninterruptible power supply EMC requirements, Category C2 Surge: IEEE 587, Category B3 RoHS: Directive 2002/95/EC Network Communications DOCSIS (RF) Port Protocols: IP, UDP, TCP, DHCP, TFTP, SNMPv1, SNMPv2c, HTTP Ethernet Port: Local Mode: HTTP web interface for local on-site diagnosis CPE Mode: DOCSIS Cable modem Ethernet CPE functionality MIBs: Power supply (ANSI/SCTE 38-4) Other SCTE HMS MIBs as defined by the SCTE for power supply and generator status monitoring Alpha proprietary advanced UPS diagnostics Cable Modem Compliance: DOCSIS 1.1 and 2.0 EuroDOCSIS 2.0 Transmit Frequency Range: 5 to 42Mhz 5 to 65Mhz Receive Center Frequency Range: 91 to 857Mhz 112 to 858Mhz Output Power Range: TDMA: +8 to +54dBmV (32QAM, 64QAM) +8 to +55dBmV (8QAM, 16QAM) +8 to +58dBmV (QPSK) S-CDMA: +8 to +53dBmV (All modulations of S-CDMA) TDMA: +68 to +114dBuV (32QAM, 64QAM) +68 to +115dBuV (8QAM, 16QAM) +68 to +118dBuV (QPSK) S-CDMA: +68 to +113dBuV (All modulations of S-CDMA) Input Signal Range: -15 to 15dBmV 64QAM: +43 to +73dBuV 256QAM: +47 to +77dBuV Channel Bandwidth: 6Mhz 8Mhz Additional Equipment XP-BSC-3-6: Wire Kit, Battery Sense, 1x36V, 6' XP-BSC-6-6: Wire Kit, Battery Sense, 2x36V, 6' XP-BSC-4-6: Wire Kit, Battery Sense, 1x48V, 6' Surge Arrestor (Alpha P/N 162-028-10): Female/Female connector configuration, "F"-type connector with integral ground block required for all installations Status Monitoring Battery State of Health (Requires AlphaApps Option): 27 AlphaNet™ IDH4 DOCSIS® Status Monitor for XM2 Family, GMX & VMX >Embedded network management for Alpha brodband power supplies >Standard network interface Web access and SNMP ANSI/SCTE HMS MIBs >Integrated network diagnostics tools >Three models available: IDH4 (standard), IDH4x (advanced) and IDH4L (XM2-300HP) AlphaNet IDH4 AlphaNet IDH4x AlphaNet IDH4L AlphaNet IDH4 for XM2 Family, GXM & VMX Power Supply Monitored Parameters Specifications Power Supply Models Supported: IDH4: XM2-HP, XM2, GXM, VMX, IDH4x: XM2-HP, XM2, GXM, VMX, IDH4L: XM2-300HP Battery Monitoring: IDH4: Up to two strings of 36 or 48V batteries (6V batteries configurable up to two strings), IDH4x: Up to four strings of 36 or 48V batteries (6V batteries configurable up to four strings), IDH4L: One 12V battery (or two if AlphaCell Batteries) Power System Management: IDH4: N/A, IDH4x: Up to five power supplies and an AlphaGen generator are managed from a single IDH4x including coordinated battery charging, system test and aggregated alarms, IDH4L: N/A Advanced Diagnostics 28 Intelligent Power Supply Interface: Power supply user interface displays advanced diagnostics including: DOCSIS modem upstream and downstream RF levels, IP address assigned by network DHCP server, MAC address and firmware levels, individual battery voltages to verify correct wire harness installation Power Inverter State of Health: Power Supply internal diagnostics report if the power inverter requires service. Reported Values: Inverter OK, Replace Inverter Major Alarm: Aggregate alarm consisting of: test fail, battery fail, line isolation alarm, output overload, inverter, over-temperature, N+1 active, fuse fail Minor Alarm: Aggregate alarm consisting of: temperature probe error, AC line loss, N+1 error Input Voltage: Reported from power supply V(in) measurement Output Voltage: Reported from power supply V(out) measurement Output Current: IDH4 and IDH4x: 0 to 25A standard on port 1, Port 2-4 requires power supply option, IDH4L: Dual outputs not to exceed 300 Watts; combined 3.5 Amps at 90Vac output voltage, 5 Amps at 60Vac output voltage Output Power: Calculated, reported in AC Watts UPS Status: AC Line, Standby, Test in progress, Test alarm Battery Voltage: IDH4: Individual battery voltage, up to two strings of 3 or 4 batteries (maximum 8 batteries), ±100mV per battery, IDH4x: Individual battery voltage, up to four strings of 3 or 4 batteries (maximum 16 batteries), ±100mV per battery, IDH4L: Individual battery voltage Battery Temperature: Reported from power supply battery Remote Temperature Sensor (RTS) Enclosure Door: Open or Closed Status Monitoring Hardware RF Cable Interface: F-connector, female, 75 Ohm, connector angle accommodates coax bend radius when installed in some enclosures Local Interface: RJ-45, Ethernet,10/100Mbps LED Indicators: Ready/Alarm, Upstream registration, Downstream lock, AlphaBus activity, RF level, Ethernet Link, CPE traffic, Battery Sense harness correctly connected I/O Control (IDH4x and IDH4L Only): 6-pin Molex: Digital input, Digital output, 5V, Common AlphaBus: RJ-11 offset tab: Multi-power supply and AlphaGen communications Battery Monitoring: IDH4: 8-pin Molex battery string A/B, IDH4x: 8-pin Molex battery string A/B and 8-pin Molex battery string C/D, IDH4L: N/A Tamper: NO or NC, software configurable, reads enclosure door magnetic switch Environment Operating Temperature: -40 to 65°C / -40 to 149°F Storage Temperature: -40 to 85°C / -40 to 185°F Humidity: 10 to 90% non-condensing Regulatory Compliance: FCC Part 15 Class A EN 50083-2:2006 EMC requirements for CATV equipment EN 62040-2:2006 Uninterruptible power supply EMC requirements, Category C2 Surge: IEEE 587, Category B3 RoHS: Directive 2002/95/EC Generator Monitored Parameters (IDH4x Only) Status: Generator Off, Running, Alarm Generator Alarm: Aggregate alarm consisting of: low oil pressure, engine overtemp, engine over-speed, crank limit, over voltage, low fuel, water intrusion, pad shear, gas hazard, test fail Gas Hazard: OK, Alarm Water Intrusion: OK, Alarm Pad Shear: OK, Alarm Enclosure Door: Open, Alarm Ignition Battery Voltage: ±100mV Enclosure Temperature: ±2°C Low Fuel: OK, Alarm Remote Test Control: Start / Stop generator test cycle Cable Modem for DOCSIS 1.1 and 2.0 Transmit Frequency Range: 5 to 42Mhz Receive Center Frequency Range: 91 to 857Mhz Output Power Range: TDMA: +8 to +54dBmV (32QAM, 64QAM) +8 to +55dBmV (8QAM, 16QAM) +8 to +58dBmV (QPSK) S-CDMA: +8 to +53dBmV (All modulations of S-CDMA) Network Communications DOCSIS (RF) Port Protocols: IP, UDP, TCP, DHCP, TFTP, SNMPv1, SNMPv2c, HTTP, SNTP Ethernet Port: Local Mode: HTTP web interface for local on-site diagnosis CPE Mode: DOCSIS Cable modem Ethernet CPE functionality Input Signal Range: -15 to 15dBmV Channel Bandwidth: 6Mhz Additional Equipment MIBs: Power supply (ANSI/SCTE 38-4) Other SCTE HMS MIBs as defined by the SCTE for power supply and generator status monitoring Alpha proprietary advanced UPS diagnostics 874-842-21 (P/N): Wire Kit, Battery Sense, 1x36V, 6' 874-842-20 (P/N): Wire Kit, Battery Sense, 2x36V, 6' 874-841-21 (P/N): Wire Kit, Battery Sense, 1x48V, 6' 874-841-20 (P/N): Wire Kit, Battery Sense, 2x48V, 6' 162-028-10 (P/N): Surge Protector: Female/Female conector configuration, "F" type connector with integralf ground block required for all installations AlphaNet™ IDH4 DOCSIS® Status Monitor for XM3-HP >Embedded network management for Alpha brodband power supplies >Standard network interface Web access and SNMP ANSI/SCTE HMS MIBs >Integrated network diagnostics tools >Three models available: IDH4 (standard), IDH4x (advanced) and IDH4L (used with AlphaGuard option) AlphaNet IDH4 AlphaNet IDH4x AlphaNet IDH4L AlphaNet IDH4 for XM3-HP Power Supply Monitored Parameters Specifications Power Supply Models Supported: XM3-HP Battery Monitoring: IDH4: Up to two strings of 36 or 48V batteries (6V batteries configurable up to two strings), IDH4x: Up to four strings of 36 or 48V batteries (6V batteries configurable up to four strings), IDH4L: N/A Power System Management: IDH4: N/A, IDH4x: Up to five power supplies and an AlphaGen generator are managed from a single IDH4x including coordinated battery charging, system test and aggregated alarms, IDH4L: N/A Management Protocol: Standard ANSI/SCTE-HMS MIBs support basic power supply monitoring. Advanced diagnostics with battery and power module analytics available via secure SNMP Advanced Diagnostics Major Alarm: Aggregate alarm consisting of: test fail, line isolation alarm, output failure, output overload, output tripped, charger failure, inverter temperature, configuration error, inverter failure, no batteries, battery failure Minor Alarm: Aggregate alarm consisting of: AC line loss, input over current/ input current limit, surge MOV failure, inverter enable, charger enable, option board failure, battery temperature probe Input Voltage: Reported from power supply V(in) measurement Output Voltage: Reported from power supply V(out) measurement Input Current: Reported in Amps Output Current: 0 to 25A standard on port 1, Port requires power supply option Input Power: Reported in AC Watts Output Power: Calculated, reported in AC Watts UPS Status: AC Line, Standby, Test in progress, Test alarm Charger Current: Reported in Amps Battery Discharge Current: Reported in Amps Battery State of Health (Requires AlphaApps Option): Power Supply internal analytic diagnostics report when batteries should be serviced. • Battery String Runtime Remaining • Battery Life Remaining Battery Voltage: IDH4: Individual battery voltage, up to two strings of 3 or 4 batteries (maximum 8 batteries), ±100mV per battery, IDH4x: Individual battery voltage, up to four strings of 3 or 4 batteries (maximum 16 batteries), ±100mV per battery, IDH4L: Individual battery voltage, up to four strings of 3 or 4 batteries (maximum 16 batteries), ±100mV per battery. Requires SAG option Utility Status and Events (Reuires AlphaApps Option): AC Line Status: • Utility Performance Status (outages, sags, surges, frequency) • Utility Events (24-hour and lifetime number of events) Battery Temperature: Reported from power supply battery Remote Temperature Sensor (RTS) Remote Test Control: Start/Stop power supply test cycle History Log Reports: • Power Supply Event Log (events of daily power supply operation) • Power Supply Configuration Log (events that occur infrequently) • Battery Event Log (battery conductance measurement and battery manufacture dates Enclosure Door: Open or Closed Generator Monitored Parameters (IDH4x Only) Status: Generator Off, Running, Alarm Hardware RF Cable Interface: F-connector, female, 75 Ohm, connector angle accommodates coax bend radius when installed in some enclosures Generator Alarm: Aggregate alarm consisting of: low oil pressure, engine overtemp, engine over-speed, crank limit, over voltage, low fuel, water intrusion, pad shear, gas hazard, test fail Local Interface: RJ-45, Ethernet,10/100Mbps Gas Hazard: OK, Alarm Water Intrusion: OK, Alarm LED Indicators: Ready/Alarm, Upstream registration, Downstream lock, AlphaBus activity, RF level, Ethernet Link, CPE traffic, Battery Sense harness correctly connected Pad Shear: OK, Alarm Enclosure Door: Open, Alarm I/O Control (IDH4x and IDH4L Only): 6-pin Molex: Digital input, Digital output, 5V, Common Ignition Battery Voltage: ±100mV AlphaBus: RJ-11 offset tab: Multi-power supply and AlphaGen communications Enclosure Temperature: ±2°C Low Fuel: OK, Alarm Battery Monitoring: IDH4: 8-pin Molex battery string A/B, IDH4x: 8-pin Molex battery string A/B and 8-pin Molex battery string C/D, IDH4L: Requires SAG Option Remote Test Control: Start / Stop generator test cycle Tamper: NO or NC, software configurable, reads enclosure door magnetic switch Transmit Frequency Range: Cable Modem for DOCSIS 1.1 and 2.0 91 to 857Mhz Output Power Range: TDMA: +8 to +54dBmV (32QAM, 64QAM) +8 to +55dBmV (8QAM, 16QAM) +8 to +58dBmV (QPSK) S-CDMA: +8 to +53dBmV (All modulations of S-CDMA) Input Signal Range: -15 to 15dBmV Channel Bandwidth: 6Mhz Environment Operating Temperature: -40 to 65°C / -40 to 149°F Storage Temperature: -40 to 85°C / -40 to 185°F Humidity: 10 to 90% non-condensing Regulatory Compliance: FCC Part 15 Class A EN 50083-2:2006 EMC requirements for CATV equipment EN 62040-2:2006 Uninterruptible power supply EMC requirements, Category C2 Surge: IEEE 587, Category B3 RoHS: Directive 2002/95/EC Network Communications DOCSIS (RF) Port Protocols: IP, UDP, TCP, DHCP, TFTP, SNMPv1, SNMPv2c, HTTP, SNTP Ethernet Port: Local Mode: HTTP web interface for local on-site diagnosis CPE Mode: DOCSIS Cable modem Ethernet CPE functionality MIBs: Power supply (ANSI/SCTE 38-4) Other SCTE HMS MIBs as defined by the SCTE for power supply and generator status monitoring Alpha proprietary advanced UPS diagnostics 5 to 42Mhz Receive Center Frequency Range: Additional Equipment 874-842-21 (P/N): Wire Kit, Battery Sense, 1x36V, 6' 874-842-20 (P/N): Wire Kit, Battery Sense, 2x36V, 6' 874-841-21 (P/N): Wire Kit, Battery Sense, 1x48V, 6' 874-841-20 (P/N): Wire Kit, Battery Sense, 2x48V, 6' 162-028-10 (P/N): Surge Protector: Female/Female conector configuration, "F" type connector with integralf ground block required for all installations 29 Status Monitoring Intelligent Power Supply Interface: Power supply user interface displays advanced diagnostics including: DOCSIS modem upstream and downstream RF levels, IP address assigned by network DHCP server, MAC address and firmware levels, individual battery voltages to verify correct wire harness installation AlphaNet™ EDH4 External DOCSIS® Transponder >Add DOCSIS Status Monitoring capability to existing power supplies AlphaNet EDH4 >Supports standard networking interfaces including SNMP, Web access and ANSI/SCTE MIBs >Multiple power supply models supported >Embedded Web server for remote diagnostics >Optional VoIP testing features AlphaNet EDH4 Hardware Specifications Power Supplies Supported: XM2-HP, XM2 (requires USM2 or USM2.5) XM (requires APM/USM) Lectro ZTT, ZTT+ AM (requires RPM card) Dimensions H x W x D (in/mm): 1.3 x 8.6 x 5.2 / 33 x 218 x 132 RF Cable Interface: F-connector, female, 75Ohm impedance DOCSIS Compatibility: DOCSIS 1.1, 2.0 Local/Craft Interface: RJ45 Ethernet Monitoring Protocol: SNMP v1, v2, v3 Devices Monitored: Power supplies, batteries, generators1 Environment Notes: 1 Reported as per ANSI/SCTE 25-3 2002 (HMS-022) Status Monitoring 30 RF Transmit/Receive Tx Frequency Range: 5 to 42MHz Output Power: 8 to 58dBmV Channel Bandwidth: 6MHz Receive Center Freq Range: 91 to 857MHz (Standard, HRC, IRC channels) Input Level: -15 to 15dBmV Operating Temperature: -40 to 65°C / -40 to 149°F Humidity: 10 to 90% non-condensing Emissions: EN55022 Class A and FCC Part 15 Class A (Installed in power supply enclosure system) Warranty: 2 years Management NMS/EMS: Standard SNMP Management Tools HMS MIBs: In addition to the standard DOCSIS MIBs, the transponder supports the following HMS MIBs: • SCTE 25-3 (HMS-022): - Interface • SCTE 36 (HMS-050): - Root • MIB SCTE 37 (HMS-072): - Tree • MIB SCTE 38-1 (HMS-026): - Property • MIB SCTE 38-2 (HMS-023): - Alarm MIB • SCTE 38-3 (HMS-024): - Common • MIB SCTE 38-4 (HMS-027): - Power Supply • MIB SCTE 38-6 (HMS-033): - Generator • MIB SCTE 38-7 (HMS-050): - TIB MIB Monitored Parameters Power Supply Data Model: XM2-HP / XM2 XM AM ZTT Series Major Alarm: Minor Alarm: Input Line Voltage: 1 1 1 Output Voltage: 1 Battery Voltage: Output Current: 1 Standby/AC Line Fail: - Equipment/Test Fail: Enclosure Door Status: Remote Test Control: Notes: 1 Requires optional cable assembly Number of Battery Strings: Up to four 36V or 48V strings Battery Data: Individual battery voltages Battery compartment temperature Continuity Software DOCSIS® Power Supply Monitoring >Enterprise-class, web-enabled and standard-based >Centralized transponder provisioning and inventory >Scheduled standby tests for preventative maintenance >Standby event dashboards > Enterprise-class Software > Scheduled Standby Tests Allow for Web-enabled and standard-based Continuity-SPS (Standby Preventative Maintenance Power Supply) is a flexible, standby power supply status Continuity-SPS allows you to proactively schedule standby monitoring solution. Based on HMS and DOCSIS standards, tests, which will alarm on risk areas on the network. A Continuity-SPS supports any standards-based transponder, dashboard graphically updates individual battery voltages providing cable operators with an enterprise-class, from standby tests every minute, making it easy to identify centralized, feature-rich, web-enabled tool to monitor all the questionable batteries. These batteries can be replaced standby power supplies in the network. during scheduled maintenance visits before they turn the next standby event into an outage. > Centralized Transponder Provisioning and Inventory 31 > Standby Event Dashboard Continuity-SPS shows all current, standby events in an provision all transponders from one central location. easy-to-read dashboard. For each event, the standby event Continuity-SPS also includes an up-to-date inventory of all dashboard displays summaries of past standby events and transponders that can be exported into Excel or CSV. shows real-time battery voltages. The standby event dashboard provides a powerful view into the network during a power outage. Status Monitoring With Continuity-SPS you can automatically discover and Enclosure Systems A solid enclosure is an essential element of the power system for any outside plant installation. With one of Alpha’s agency-certified enclosures, your power systems are protected from changes in the climate, weather or theft. >LPE Enclosure The LPE is an ideal solution for cable network power when traditional equipment is too large or bulky. Designed for multiple dwelling units and Fiber Deep applications, the LPE is more than 40 percent smaller than a standard PWE-3 enclosure. Engineered to work with the XM2-300HP power supply, the LPE enclosure offers a low-profile solution to keep your customer’s communication networks alive. >NPS Enclosure The NPS enclosure is optimal for use in business park, node segmentation and plant extension applications. It is specifically designed for indoor and outdoor installations requiring lower power, a smaller footprint and embedded DOCSIS® or proprietary status monitoring capability. The NPS features equipment rack, wall, pole, floor or pedestal mounting options. >Pole Mount Enclosures Alpha’s Pole Mount enclosures are the most durable broadband power supply enclosures in the industry. Each enclosure features a removable door and lid. Standard features include high magnetic circuit breaker, duplex AC receptacle and service power inserter. Options include battery integration tray, surge protector, battery heater mat, storm hood and battery expansion cabinets. >Ground Mount Enclosures >Extended Runtime Add-on Enclosures Alpha’s battery expansion cabinet options include top and bottom mount cabinets for most standard Alpha enclosures, as well as stand alone options to work with any broadband enclosure. >Enclosure Accessories Extend battery runtime and protect your power system investment. Security add-ons help prevent theft of valuable equipment, while accessories like battery heater mat and battery spacers help get the best performance from your batteries in any climate or condition. >Powernode Systems Alpha’s Powernode (PN) Series enclosures offer flexibility and modular expandability for broadband power applications. Supporting centralized or distributed power architectures, PN Series enclosures accommodate multiple power supplies, battery strings and natural gas or propane generators. >Fibernode Power Enclosure Designed for collocated power and fibernode configurations, the FPE enclosure provides a rugged outdoor solution for multiple outside plant and fiber deep applications. With easy front, rear and top access, and a universal node mounting bracket and wire management, the FPE provides a complete system solution for expanding HFC networks. >Surge Protection Alpha’s surge protection devices provide reliable protection of power supplies and related equipment from the damaging powerline disturbances common to cable broadband applications. >Precast Pads for Enclosures Alpha offers a full line of precast, polymer concrete pads for most Alpha enclosures systems. >Pedestal Support Series Alpha provides two pedestal support systems for the UPE Series ground mount enclosures. 33 Enclosure Systems Alpha’s Ground Mount enclosures can be seen installed all over the world. Each enclosure features a removable door and lid. Standard features include high magnetic circuit breaker, duplex AC receptacle and service power inserter. Optional features include a battery integration tray, surge protector, battery heater mat, storm hood, battery expansion cabinets and meter enclosure models. MDU and Fiber Deep System Pole, Wall or Ground Mount Options >XM2-300HP 300 Watt Intelligent CableUPS® up to 94% efficient with a small carbon footprint >Smart DOCSIS transponder for advanced status monitoring >Advanced inverter and battery diagnostics >Dual temperature probe for advanced battery management As we transition from traditional HFC to Fiber Deep topologies, sometimes the right power is less power. Alpha’s new XM2-300HP/LPE powering system incorporates DOCSIS® communications to provide an efficient and economical outside plant solution. The 300W output offers maximum reliability to support low power applications in expanding broadband networks. Enclosure Systems 34 XM2-300HP CableUPS® SPI-RF High efficiency 300W power supply Ideal for RFoG, MDU and N+1/N+0 applications Small footprint and lightweight Integrated DOCSIS® status monitoring New predictive preventative maintenance features Programmable LCD Smart Display Single network interconnect for power and DOCSIS RF monitoring RF attenuation control with SXP Pad -110 dBC EMI shielded cast aluminum package AC test points “ALT/ON” switch for Service Power Supply 24 month warranty DPM Dual Temperature Probe Ambient Temperature DOCSIS® based status monitoring card Advanced battery monitoring capability Detailed RF level indicators LAP-SM Surge Protector Pass through status monitoring Critical protection from voltage transients LA Series features piggyback plug to optimize receptacle use Battery Temperature A single cable monitors dual ambient temperature for the battery negative terminal and enclosure Advanced battery management AlphaCell™ 4.0HP Battery Pure lead technology provides up to 20% increased life expectancy 3 to 5 times longer shelf life vs. standard VRLA Up to 5-year full warranty Non-spillable UN2800 rating for ease of transportation Provides up to 50% increased runtime in coldest climates 4.0HP offering 240 cable runtime minutes LPE Enclosure Indoor/Outdoor Enclosure >Wall mount, pole mount and ground mounting options >40% smaller than industry standard PWE-3 system >Innovative thermal management airflow system LPE Enclosure LPE Enclosure Mechanical Innovative Convective Airflow System Dimensions H x W x D (in/mm): 26 x 16.5 x 12 / 661 x 420 x 305 Weight (lb/kg): 25 / 11.3 Material: Exterior powdercoated aluminum Battery: 220GXL or two 70HPL-FTs Door and Lid Seal: Poron gasketing Color: Gray (custom colors available) Lid: Removable Door: Hinged, removable Slanted lid draws heat up and out “Chimney effect” provides active convection cooling 35 Options Pole mount bracket, wall mount bracket, ground mount bracket Battery Heater Mat: Used in cold-climate applications Battery Retaining Bar (BRB): Secures batteries within enclosure Coax Connection: SPI or SPI-RF Door Locks: Optional GEM lock Lightning Arrester: LA-P+ 120V, LA-P-120T, Surge Arrester Kit Service Entrance: 70A available Status Indicators: Local/Remote Indicator (LRI) Coax Surge Protection: 75 Ω Coax, MF 75 Ω Coax, FF w/Gnd 75 Ω Coax, FF Hotter Extreme weather resistant louver free design Cool air intake through bottom of enclosure Cooler Other Cost Effective Indoor Wall Mount Options Smallest Available Footprint Volume = 10.8ft3 Volume = 7.2ft3 Volume = 2.8ft3 Wall Mount Shelf with SPI mount bracket UPE-6 – ground mount ­ PWE-6 – pole mount ­ LPE – pole mount / wall mount shown­ Wall Mount Rack (WMR) Enclosure Systems Mounting Hardware: Node Power System Rack, Pole, Wall or Floor Mount Options >For low power applications including Fiber Deep up to Node + 6 actives >Optional AlphaGuard™ battery balancer and SPI-RF service power inserter >Multiple battery configurations for extended runtime The Node Power Supply (NPS) enclosure is an integrated CableUPS® system for use in Multi Dwelling Units (MDU), business parks, node segmentation and plant extension applications. The NPS is specifically designed for indoor or outdoor installations requiring lower power, a smaller footprint and embedded DOCSIS® or proprietary status monitoring capability. The NPS can be conveniently mounted in an equipment rack, a wall, pole, or to a floor pedestal using the 36 appropriate installation kit. The NPS is an ideal solution for back-up power where traditional equipment is too large Enclosure Systems and bulky. CableUPS® Enclosure fits XM2-906HP and XM2-300HP Industry leading highest efficiency for lower operating costs Featuring i2M™ Intelligent Inverter Module for XM2-HP and XM2 Platforms Displays Critical Smart DOCSIS® parameters and individual battery voltages Sharper easy-to-read blue LCD Smart Display SPI-RF Single network interconnect carrying system power and DOCSIS® RF monitoring signals RF level control with SXP PAD FRT shielded cast aluminum package Enclosure Cooling Fan (ECF) Systems Enclosure Cooling Fan enhances air circulation in an enclosure's battery compartment Air flow eliminates “hotspot” premature battery failures in hotter climates Significantly reduces the power supply compartment temperature AlphaGuard™ Extends battery life Spreads charge voltage equally across batteries Compensates for battery differences as they age Identify and replace single suspect batteries, not the entire string Single battery connections for charge management and status monitoring Batteries Deliver 100% “out-of-box” capacity — no cycling required Premium Gel model offers 50% longer life than traditional gel batteries Silver Alloy minimizes grid corrosion Maintenance-free threaded inserts; no periodic retorquing Front terminal design with protective covers High cyclic life capability Flame retardant case and cover (to UL94VO) 3-step terminal seal design ensures leak-free operation Integral handles (115HPL-FT, 220HPL-FT) for ease of handling NPS Enclosure Indoor/Outdoor Enclosure >Engineered for broadband powering applications >22% smaller than industry standard PWE-3 system >Convenient pole, wall, ground and rack mount options >Aluminum-welded construction and durable powdercoated exterior >Multiple enclosure accessories and options available NPS Enclosure (Rack mount option) NPS Enclosure (For use with XM2-906HP and XM2-300HP) Models: NPS-R NPS-W1 NPS-W2 NPS-F NPS-P Installation: Indoor Indoor Outdoor Indoor Outdoor Description: 19" and 23" rack mount Wall mount Wall mount Floor mount Pole mount Dimensions H x W x D (in/mm): 22.75 x 19 x 14.14 / 578 x 432 x 359 22.75 x 17 x 14.14 / 578 x 432 x 359 22.75 x 17 x 14.14 / 578 x 432 x 359 22.75 x 17 x 14.14 / 578 x 432 x 359 22.75 x 17 x 14.14 / 578 x 432 x 359 Weight (lb/kg): 39 / 17.7 39 / 17.7 39 / 17.7 39 / 17.7 39 / 17.7 Configurations Mechanical 37 Node Power Supply Enclosure Configurations: Shown with 115 HPL Batteries Specifications Material: Exterior powdercoated aluminum Door: Hinged removable Door and Lid Seal: Poron gasketing Tamper Switch: Optional Color: Gray (custom colors available) Battery Side Tray: Optional Lid: Removable Smallest Available Footprint Volume = 3.54ft3 Volume = 4.8ft3 PWE-3 – pole mount ­ NPS – rack mount Enclosure Systems Shown with GXL Batteries PWE Enclosure Outdoor Pole Mount Enclosures >Engineered for broadband powering applications >Aluminum welded construction and durable powdercoated exterior >Agency certified to meet applicable industry standards >Internal or external SUSE rated service entrance options >Optional Battery Integration Tray (BIT) PWE-3 >Portable generator cabling access door >Optional Northern Enclosure available for colder climates PWE Enclosures PWE-3 PWE-3 Northern Enclosure PWE-4 PWE-6 PWE-6 Northern Enclosure Dimensions H x W x D (in/mm): 24.5 x 24.3 x 14 / 622 x 615 x 355 25.4 x 24.8 x 14.1 / 645 x 628 x 359 24.8 x 30.3 x 16 / 629 x 768 x 406 36.8 x 24.3 x 14 / 933 x 615 x 355 37.7 x 24.8 x 14.1 / 958 x 628 x 359 Weight (lb/kg): 39 / 18 (without batteries) 42 / 19.1 (without batteries) 57 / 26 (without batteries) 68 / 31 (without batteries) 73 / 33.1 (without batteries) PWE-6FT PWE-8 PWE-9 PWE-D36 Dimensions H x W x D (in/mm): 27.5 x 29.3 x 17.5 / 698 x 753 x 445 36.9 x 30.3 x 16 / 937 x 768 x 406 47 x 24.3 x 14 / 1194 x 615 x 355 47 x 24.3 x 14 / 1194 x 615 x 355 Weight (lb/kg): 57 / 26 (without batteries) 121 / 55 (without batteries) 85 / 38.5 (without batteries) 75 / 34 (without batteries) Models: Mechanical Enclosure Systems 38 PWE Enclosure Configurations PWE Enclosures (cont.) Models: Mechanical PWE Enclosure Configurations Specifications Northern Enclosure Hood and Door for Colder Climates Material: Exterior powdercoated aluminum Door and Lid Seal: Poron gasketing Color: Gray (custom colors available) Lid: Removable Door: Hinged removable Pole Mount: Galvanized steel brackets for wood and concrete pole mount and wall mount Tamper Switch: Optional Battery Side Tray: Optional Northern Enclosures feature Z-bracket, vented hood and doors with no batting required. UPE and UPE-M Enclosures Outdoor Ground Mount Enclosures >Engineered to accommodate broadband powering applications >Internal or external SUSE rated service entrance options available >Enclosures are CSA/UL certified to meet applicable industry standards >Aluminum-welded construction and durable powdercoated exterior >Portable generator cabling access door >Multiple enclosure accessories and options available UPE-6 UPE - Ground Mount Enclosures Models: UPE-3 UPE-4 UPE-6 UPE-6L UPE-8 Dimensions H x W x D (in/mm): 33.5 x 26 x 15 / 851 x 660 x 381 35 x 34.5 x 15 / 889 x 876 x 381 48 x 26 x 15 / 1219 x 660 x 381 36 x 26 x 15 / 914 x 882 x 381 45.5 x 34.5 x 15 / 1136 x 882 x 381 Weight (lb/kg): 61 / 28 (without batteries) 72 / 32 (without batteries) 75 / 34 (without batteries) 68 / 30 (without batteries) 121 / 55 (without batteries) Mechanical 39 UPE Configurations: Models: UPE-M3 UPE-M6 UPE-M8 Dimensions H x W x D (in/mm): 45 x 26 x 19.7 / 1143 x 660 x 482 57.3 x 26 x 19.7 / 1455 x 660 x 482 50 x 32 x 20.5 / 1270 x 813 x 521 Weight (lb/kg): 100 / 44 (without batteries) 130 / 59 (without batteries) 140 / 64 (without batteries) Mechanical UPE-M Configurations: Specifications Material: Exterior powdercoated aluminum Door and Lid Seal: Poron gasketing Color: Gray (custom colors available) Lid: Removable Door: Removable/lockable Ground Mount: Precast polymer concrete pad (optional) Tamper Switch: Optional Battery Side Tray: Optional Enclosure Systems UPE - Metered Ground Mount Enclosures Extended Runtime Enclosures >Upgrade existing Alpha enclosures >Extend existing runtimes by up to 300% >Plant hardening option for voice and data broadband networks >Generator options available BE-PWE mounted on PWE-3 BE-PWE Adds battery capacity to the PWE-3 Enclosure Installs onto top of PWE-3 Kit Includes enclosure with sliding battery tray, door, battery cabling and pole mount bracket Compatible with AlphaCell® 165, 195 and 220 Batteries UBE-PWE Enclosure Options 40 Adds battery capacity to the PWE-3 Enclosure Installs onto bottom of PWE-3 Kit Includes enclosure with sliding battery tray, door, battery cabling and pole mount bracket Compatible with AlphaCell 165, 195 and 220 Batteries BE-UPE LBE-3 Adds battery capacity to Lectro 3 battery pole mount enclosure Installs onto bottom of Lectro Enclosure Kit Includes enclosure with sliding battery tray, door, battery cabling and pole mount bracket Compatible with AlphaCell 165, 195 and 220 Batteries Underground Battery Vaults Thermally stable underground environment helps promote maximum battery life and performance Reduces visual impact with below-grade battery installation Durable, maintenance-free, long-lasting, utility approved and non-combustible material Large battery capacity houses up to eight batteries for extended backup time Flexible enclosure options for both pole and ground mount systems PWE Generator Expansion Module Adds battery capacity to the UPE-3 Enclosure Kit Includes enclosure and battery cabling Compatible with AlphaCell 165, 195 and 220 Batteries PWE-SG Adds battery capacity to any OEM pole mount enclosure Installs underneath of existing pole mount enclosure Kit includes conduit kit, battery cabling and pole mount bracket Accommodates 3 or 4 AlphaCell 165, 195 or 220 Batteries Provides an easy means to pole mount the AlphaGen™ EU2000 Protects generator from inclement weather Prevents theft of valuable portable generators Field installable using two rails attached to the bottom of the PWE Backwards compatible with existing enclosure Accommodates Line Transfer Switch (LTS) Can be easily removed after extended outage or left in place Designed to provide four to ten hours of additional runtime Universal Generator Expansion Module Add an AlphaGen EU2000 to an Alpha PWE or UPE Enclosure Protects generator from inclement weather Prevents theft of valuable portable generators Backwards compatible with existing enclosure Can be easily removed after extended outage or left in place Designed to provide four to ten hours of additional runtime Enclosure Accessories >Retrofit existing enclosures >Easy installation and maintenance >Cooling options extend battery and power supply life >Heating options for maximum protection Enclosure Cooling Fan (ECF) Systems PWE/UPE series The Enclosure Cooling Fan enhances air circulation in an enclosure's battery compartment Air flow eliminates “hotspot” premature battery failures in hotter climates Significantly reduces the power supply compartment temperature Calculated Mean Time Between Failure (MTBF) studies indicate this will extend power supply life by two years PowerNode series Battery Spacer Clip (BSC) Battery Retaining Bar Provides added security against the batteries from falling out or being thrown from an enclosure Easily snaps into place Prevents power supply from sliding off the shelf or being thrown from an PWE enclosure Bolted to enclosure and clips to handle of supply Constructed of braided steel cable and carabiner style clips Battery Integration Tray (BIT) Factory installed option in any new PWE-3/6 and UPE-3/6 enclosures Eliminates battery cable kits and slide trays Greatly reduces battery preventative maintenance Pre-wired voltage sense leads for transponder and AlphaGuard Allows for the direct connection of generator 41 Battery Heater Mat Consumes 30% less power than previous designs Durable polyester construction and insulated design Sealed on-mat electronics for maximum protection On-mat thermal switch and thermal fuse for redundant safety Piggyback plug standard on 120V models Ladder Bracket Provides safe access for servicing power supplies and batteries without a bucket truck Attaches to PWE enclosures; does not require a pole attachment point Heavy-duty galvanized steel construction Includes a safety belt attachment location accepting strand hook ladders less than 20" in width Enclosure Options Designed for use with most group 27 or 31 VRLA batteries Easy installation - clips to the top of the battery Increases battery life expectancy by providing critical battery spacing required for proper ventilation Accurately positions and secures the Remote Temperature Sensor (RTS) Strongly recommended for hot climates Designed to last over 30 years or lifetime of the equipment Module Retaining Cable Security Enclosure Accessories >External security options available to prevent unauthorized entry and serve as theft deterrent >Internal security solutions to protect costly power system components >Multiple security options available to maximize power system investment PWE High Security Device High visibility theft deterrent Stainless steel construction - corrosion resistant Locking system prevents access to padlock shackle (to prevent cutting of lock) Ground Mount Security Bar For UPE / UPE-M / PN Enclosures 42 High visibility theft deterrent Powdercoated-corrosion resistant Locking system prevents access to padlock shackle (to prevent cutting of lock) Enclosure Options AlphaCell® Anti-Theft Label Destructible vinyl - made to fracture if tampered with. Will not easily peel off Temperature and chemical resistant Large, identifiable size (4x6) Customizable with logo PWE High Security Device Battery Security Device This custom-fitted framework secures the batteries in the equipment enclosure. A hinged, double-wall reinforced cross beam with enclosed padlock housing locks the batteries in place, while still allowing access by service personnel for maintenance. Heavy-duty design and powdercoated steel construction provide the appropriate level of security to system batteries. Security Bar Kit Alpha’s Enclosure Security Bar prevents unauthorized access to pole-mount power system enclosures. It also helps secure enclosure contents during unforeseen emergency or natural disaster situations. Heavy-duty reinforced steel construction and swing-away hinged design strike the right balance between protection and serviceability. An enclosed padlock housing further protects the enclosure from unauthorized access. DeWalt MobileLock Nationwide GPS Locator with Anti-Theft controls Customizable alarm sensors (vibration, tamper, temperature) Long life battery (up to 1 month) Mobile alert via email or cell phone Tamper Switch This magnetic door switch provides an intrusion alarm through remote status monitoring and may be ordered with normally-closed or normallyopen contacts. Power Supply Hold-Down Bracket This security device consists of a metal framework wrap that secures the power supply in place, guarding against theft, vandalism and movement during natural disasters or other extreme conditions such as traffic accidents. Safety Padlock This hardened steel, corrosion-resistant, thinprofile padlock is a critical element in preventing unauthorized access while still allowing keyed entry to secured areas. Additionally, restricted keyways, customer-specific key codes and exclusive key blanks allow operators to establish a comprehensive keying strategy. It is an excellent addition to other Alpha Security Accessories as its size and thin-profile design fit within the enclosed padlock housings. HSHP Enclosure High Security High Performance Enclosure >All-in-one maximum security enclosure >Internal and external security provisions to prevent against unauthorized entry >Flush surface design and concealed hinges limit pry points >Added security options for exclusive senior management dual-key access Internal Battery Security Bar HSHP Enclosure Weldable Tabs Internal Security Bar locks the batteries inside the enclosure. Exclusive Alpha security screws are required to attached the bar to the shelf and the bottom hooks into the internal base plate. Concealed Hinges Optional tabs can be added to the top and bottom of the door which can be welded closed. A grinder is required to remove the tabs. Enclosure features concealed hinges prohibiting any external access. The internal hinges are equipped with a release pin to remove the door when servicing. 43 High Security Latch Key Locks The enclosure's constructed with a recessed door to limit prying points. Attempts to pry will cause the until to lock up the door frame. Equipped with internal lock latches that hook directly into the enclosure to protect from access to prying. Custom Keyed Security Bolt An Alpha exclusive security screw is provided to lock the power supply directly to the cabinet itself. This feature adds senior management dual-key access. Optional Mul-T-Locks Optional 3-in-1 changeable combination cylinder for maximum protection Reinforced Door Design The enclosure door is reinforced with an internal U-Channel frame around the entire perimeter of the door. When door is closed, the internal U-Channel is locked between the enclosure and the door. Enhanced Lid: The lid is security bolted to the enclosure and nested to the enclosure to enhance overall strength of the enclosure and limit pry points. Enclosure Options Recessed Door Design Powernode Systems Extended Runtime Powering >Supports centralized or distributed powering architectures >Compatible with AlphaGen™ generator systems or multiple battery strings for extended runtime solutions PN-3 with AlphaGen CESC Specifications Enclosure Systems 44 CESC Dimensions H x W x D (in/mm): 44 x 15 x 24 / 1118 x 381 x 610 Weight (lb/kg): 51 / 23.13 Power Supply Capacity: One power supply Color: Seafoam Green, optional colors available Standard Features: Removable/lockable doors Finish: Durable powdercoat exterior Material: Aluminum Sidecar 1 Power Supply, 1 Battery String PN-3 Specifications Dimensions H x W x D (in/mm): 44 x 26 x 24 / 1118 x 660 x 610 Weight (lb/kg): 115 / 52 (without trays) Power Supply Capacity: Up to two power supplies Color: Seafoam Green, optional colors available Standard Features: Removable/lockable doors Finish: Durable powdercoat exterior Material: Aluminum Single PN-3 Dual PN-3 PN-3/CE-3X2 1 Power Supply 2 Battery Strings 2 Power Supplies 4 Battery Strings 2 Power Supplies 1 Battery String AlphaGen™ Generator The PN-3 enclosure can accommodate a maximum combination of three equipment or battery trays. PN-3-HS (High Security) Specifications Dimensions H x W x D (in/mm): 44 x 26 x 24 / 1118 x 660 x 610 Weight (lb/kg): 115 / 52 (without trays) Power Supply Capacity: Up to two power supplies Color: Seafoam Green, optional colors available Standard Features: Removable/lockable doors Finish: Durable powdercoat exterior Material: Aluminum PN-3-HS PN-3/SC-HS PN-3/SC-HS Battery Cabinet 3 Battery Strings Sidecar and Battery Cabinet 1 Power Supply 4 Battery Strings High Security Locks The PN-3/SC-HS system has recessed star bolt security locks to prevent unauthorized entry. Reinforced door frames. Doors reinforced with welded channel for strength. Powernode Systems Extended Runtime Powering >SUSE and EUSERC rated options available >CSA/UL certified to meet applicable industry standards >High security options PN-4 with AlphaGen CESC-3x2 Specifications CESC-3x2 Dimensions H x W x D (in/mm): 44 x 41 x 24 / 1118 x 1041 x 610 Weight (lb/kg): 428 / 194.1 (without trays) Power Supply Capacity: One power supply Color: Seafoam Green, optional colors available Standard Features: Removable/lockable doors Finish: Durable powdercoat exterior Material: Aluminum 1 Power Supply 1 Battery String AlphaGen™ Generator 45 The most compact, cost effective “allin-one” power system. The CESC-3x provides for a single power module, batteries, and generator in a low profile, minimum footprint design. Specifications Dimensions H x W x D (in/mm): 52 x 26 x 24 / 1320 x 660 x 610 Weight (lb/kg): 145 / 66 (without trays) Power Supply Capacity: Up to three power supplies Color: Seafoam Green, optional colors available Standard Features: Removable/lockable doors Finish: Durable powdercoat exterior Material: Aluminum Single PN-4 Dual PN-4 PN-4/CE-9X2 2 Power Supplies 2 Battery Strings 3 Power Supplies 4 Battery Strings 2 Power Supplies 2 Battery Strings AlphaGen Generator The PN-4 enclosure can accommodate a maximum combination of four trays. A maximum of either three power modules or three battery trays can be installed. PN-6 Specifications Dimensions H x W x D (in/mm): 39 x 52 x 24 / 990 x 1321 x 610 Weight (lb/kg): 250 / 113 (without trays) Power Supply Capacity: Up to three power supplies Color: Seafoam Green, optional colors available Standard Features: Removable/lockable doors Finish: Durable powdercoat exterior Material: Aluminum PN-6 PN-6 PN-6 and PN-6X 3 Power Modules 2 48V Battery strings Optional Battery Drawer 3 Power Modules 4 48V Battery strings 3 Power Modules 2 48V Battery strings Optional Battery Drawer AlphaGen Generator The PN-6 offers a low profile design that accommodates up to three power modules. An optional Battery Drawer (BD-8) fits under the PN-6 to provide easy access storage for up to eight batteries. Note: PN-6 with PN-6x dimensions are (in/mm) 57H x 91W x 24D / 1448H x 2311W x 610D with BD-8 and generator pedestal. PN-6 with PN-6x dimensions are (in/mm) 39H x 91W x 24D / 991H x 2311W x 610D without BD-8 and generator pedestal Enclosure Systems PN-4 Fibernode Power Enclosure >Designed for collocated power and fiber node configurations >Thermally optimized for todays fiber nodes >Flexible configurations to accommodate multiple fiber deep applications Fibernode Power Enclosure (Front) Architecture — N+1 (Approximately 6 Actives) XM2-906HP, 3 or 6 AlphaCell® Batteries and a DCX3000 Portable Generator XM2-906HP Runtime (Hrs) 3 Batt Load 195 GXL 6 Batt 4.0HP 195 GXL DCX-3000 4.0HP Max. Runtime** 2 14.1 17.3 29.9 37.4 20.0 57.4 3 10.1 12.4 21.6 26.7 19.9 46.6 4 7.7 9.5 16.6 20.5 19.8 40.3 4.6* 6.7 8.3 14.5 17.9 19.8 37.7 5 6.2 7.7 13.4 16.5 19.7 36.2 * 4.6A = 417W @ 90V ** Max. Runtime with 4.0HP and DCX-3000 Node Plus 1 Architecture* 46 .55 A 1.3 A .55 A .55 A .55 A Enclosure Systems .55 A Example = 417 Watts @ 90 VAC .55 A 1 x 1.3 AMP = 120 Watts @ 90 VAC 6 x .55 AMP = 3.3 AMP = 297 Watts @ 90 VAC Architecture — N+2 (Approximately 20 Actives) XM2-918HP, 3 or 6 AlphaCell Batteries and a DCX3000 Portable Generator XM2-918HP Runtime (Hrs) 3 Batt 6 Batt DCX-3000 Max. Runtime** 13.4 19.5 32.9 10.1 18.5 28.6 6.4 8.0 17.0 25.0 3.1 5.2 6.6 15.0 21.6 2.2 3.1 5.1 6.4 14.8 21.1 14 1.9 2.7 4.3 5.5 13.5 19.0 16 1.6 2.3 3.7 4.7 12.0 16.7 Load 195 GXL 4.0HP 195 GXL 4.0HP 6 5.0 6.3 10.9 8 3.7 4.8 8.2 10 2.9 3.8 12 2.3 12.3* * 12.3A = 1110W @ 90V ** Max. Runtime with 4.0HP and DCX-3000 Node Plus 2 Architecture* .55 A .55 A .55 A .55 A .55 A 1.3 A .55 A .55 A .55 A .55 A .55 A .55 A .55 A .55 A .55 A Example = 1110 Watts @ 90 VAC .55 A .55 A 1 x 1.3 AMP = 120 Watts @ 90 VAC 20 x .55 AMP = 11 AMP = 990 Watts @ 90 VAC .55 A .55 A Fibernode Power Enclosure >Universal node mounting bracket provides easy installations >36" width allows for horizontal node mounting >High security option available >Easy front and rear access Fibernode Power Enclosure (Rear) Architecture — N+0 XM2-300HP, 1 AlphaCell Battery and 2-Battery Back-up Pack XM2-300HP Runtime (Hrs) 1 Batt Back-up Pack** 4.0HP 4.0HP 0.5 28.0 60.1 88.1 1.0 14.0 30.1 44.1 Load Max. Runtime w/ 4.0HP and B/U Pack 1.3* 10.5 22.7 33.3 1.5 9.1 19.6 28.7 20.8 2.0 6.6 14.1 2.5 5.1 10.9 16.0 3.0 4.2 8.8 13.0 * 120W Node or 1.3A @ 90V ** Additional runtime back-up pack of 2 AlphaCell 4.0HP batteries 47 Fibernode Power Enclosure Specifications 45 x 36 x 32 / 1143 x 914.4 x 812.8 Weight (lb/kg): 145 / 66 (without trays) Power Supply Capacity: Up to two power supplies Color: Seafoam Green, optional colors available Standard Features: Removable/lockable doors Finish: Durable powdercoat exterior Material: Aluminum Architecture — 8N+2 (8 Nodes with 1-2 Actives Each) XM2-924HP, 4 or 8 AlphaCell Batteries and a DCX3000 Portable Generator XM2-924HP Runtime (Hrs) Load 4 Batt 8 Batt 4.0HP 4.0HP Max. Runtime w/ 4.0HP and DCX DCX-3000 14 3.6 7.6 13.5 21.1 16 3.1 6.6 12.0 18.6 17* 3.0 6.2 11.5 17.7 18 2.8 5.8 11.0 16.8 20 2.5 5.1 9.5 14.7 22 2.2 4.6 9.0 13.6 * 17A = 1530W @ 90V 8 Nodes Plus 1 Architecture .55 A 1.3 A 1.3 A .55 A .55 A .55 A 8 Fiber Nodes with 1-2 Actives Fed by One XM2-924HP 1.3 A .55 A 1.3 A 1.3 A .55 A Example = 1530 Watts @ 90 VAC = 17A @ 90 VAC 1.3 A .55 A .55 A 8 x 1.3 AMP = 10.4 AMP = 940 Watts @ 90 VAC .55 A 12 x .55 AMP = 6.6 AMP = 594 Watts @ 90 VAC .55 A .55 A .55 A 1.3 A 1.3 A Enclosure Systems Dimensions H x W x D (in/mm): Surge Protection >UL 1449 3rd Edition Approved >Critical protection from voltage transients LA-P+ LA-P-120T ISA-120/240 >Plug-in or hardwired solution utilizing Metal Oxide Varistor (MOV) protection >VSS 120/VSS 240 Series provides downed power line protection VSS 120/VSS 240 Surge Protection Operating Voltage: 120V Models Model Selection Good Better Best Series Model: LA-P+ 120 LA-P-120T VSS 120-15 / NO Outlet Type / Pass Thru: Enclosure Options 48 / YES 240V Model 2 120/240V Models Best Best Good Best VSS-120-202 ISA 120/2401 LA-P+240 VSS2402 / YES / Yes Hardwired / NA / NO / YES Protection: L / N /G L/N/G L/N/G L/N/G L/N/G L1 / L2 / G L1 / L2 / G Operating Temperature: -40 to 55°C / -40 to 131˚F -40 to 55°C / -40 to 131˚F -40 to 55°C / -40 to 131˚F -40 to 55°C / -40 to 131˚F -40 to 55°C / -40 to 131˚F -40 to 55°C / -40 to 131˚F -40 to 55°C / -40 to 131˚F LED Indicator: Yes Yes Yes Yes Yes Yes Yes UL 1449 3rd Edition Specifications Voltage Let Through Protection Rating: 700Vp 500Vp 500Vp 500Vp 700Vp / 1200Vp 1200Vp 500Vp Nominal Discharge Current Rating 3kA 3kA 20kA 20kA 10kA 3kA 20kA Maximum Continuous Operating Voltage (MCOV): 150Vac 130Vac 275Vac 275Vac 150Vac / 300Vac 320Vac 275Vac Notes: 1 The ISA surge protection devices are factory wired on the load side of the service entrance and available for field replacement. These arrestors should be installed by a licensed electrician. 2 UL1449 3rd edition not required COAX Protectors COAX Protector Specifications Ideally suited to protect costly status-monitoring transponders, digital set top boxes, cable modems and satellite receivers in the headend as well as high-end HDTV sets from potentially damaging surges. The patented coaxial gas tube surge protector is equipped with an integral fail-safe mechanism. Listed to UL 497, CSA Listed Certified and complies with 1999 national Electric Code. Part Number: • Patented In-Line® Coaxial gas tube surge protection • Provide lightning and surge protection for distribution, customer premises and headend equipment • Improves broadband network reliability and reduces service outages • Power passing • Listed to UL 497, CSA Listed Certified & complies with NEC Part Number Description 162-029-10: Female/Female connector configuration, “F” type connector 162-027-10: Male/Female connector configuration, “F” type connector 162-028-10: Female/Female connector configuration, “F” type connector with integral ground block 162-029-10/162-027-10 162-028-10 RF Performance Frequency Range: DC – 1.0 GHz 1.0 GHz to 1.5 GHz Characteristic Impedance: 75 Ohms 75 Ohms Insertion Loss (includes flatness): <0.3dB / 0.2dB typical <0.3dB Return Loss: >30dB > 20dB Protection DC Breakdown @ 2000V/s: 150V to 300V Impulse Breakdown @ 100V/µs: < 450V Insulation Resistance: > 100 MegOhms Surge Life* 10A, 10/1000µs: >1500 Surges 100A, 10/1000µs: >100 Surges 1000A, 10/1000µs: >10 Surges 5000A, 8/20µs: >10 Surges AC Life 5A, 1000Vac, 1s: >5 Operations 1A, 1000Vac, 1s: >60 Operations Failshort COAX Protectors 30A, 1000Vac: >15min Operating Temperature: -40 to 65°C / -40 to 149°F * All specifications for service life only Precast Pads For Alpha Enclosures >Polymer concrete pads are reinforced with mineral aggregates >Precast concrete pads are made from highstrength fiber-cement and lightweight concrete >Includes 3/8" mounting hardware Polymer Concrete (PCC) Models: Enclosure PCC-3: PN-3 or PN-4 PCC-3-3X: PN-3 + PN-3 or PN-4 + PN-4 PN-3 + CE-3X2 or PN-4 + CE-9X2 PCC-3X: CE-3X2 or CE-9X2 PCC-3X-3G: CE3X2 + CE3G or CE-9X2 + CE3G PCC-3-3: Precast Concrete (PCD) 7.5K PCC-A-PN6: PN-6 (Part 1 of 2) PCC-B-PN6X: 7.5K (Part 2 of 2) PCC-PN6: PN-6 PCC-RMB: RMB PCC-SC: CESC PCC-SC-3X: CESC + CE-3X2 or CESC + CE-9X2 PCC-SCFN: SCFN PCC-SC-RMB: SC + RMB PCC-UPE: PCC-UPEM: UPE-3, UPE-4, UPE-6 or UPE-8 UPE-M3, UPE-M6 or UPE-M8 Weight (lb/kg) Models: Enclosure 36 x 38 x 3 / 914 x 965 x 76 36 x 65 x 3 / 914 x 1651 x 76 36 x 65 x 3 / 914 x 1651 x 76 36 x 38 x 3 / 914 x 965 x 76 36 x 64 x 3 / 914 x 1626 x 76 51 x 36 x 3 / 1295 x 914 x 76 29 x 58 x 3 / 736 x 1473 x 76 29 x 42 x 3 / 736 x 1066 x 76 36 x 64 x 3 / 914 x 1626 x 76 44 x 42 x 3 / 1117 x 1066 x 76 27 x 36 x 3 / 685 x 914 x 76 36 x 54 x 3 / 914 x 1372 x 76 27 x 36 x 3 / 685 x 914 x 76 44 x 54 x 3 / 1117 x 1371 x 76 28 x 45 x 3 / 711 x 1143 x 76 40 x 40 x 3 / 1016 x 1016 x 76 120 / 54.4 PCD-3: PN-3 or PN-4 195 / 88.4 PCD-3-3: 200 / 90.7 PCD-3-3X: 120 / 54.4 PCD-3-3X-3G: PN-3 + PN-3 or PN-4 + PN-4 PN-3 + CE-3X2 or PN-4 + CE-9X2 PN-3 + CE-3X2 + CE-G or PN-4 + CE-9X2 + CE-G 190 / 86.1 PCD-3X: CE-3X2 or CE-9X2 190 / 86.1 PCD-3X-3G: CE-3X2 + CE-3G or CE-9X2 + CE-9G 232 / 106.5 PCD-A-PN6: PN-6 (Part 1 of 2) 125 / 56.6 PCD-B-PN6X: 7.5K (Part 2 of 2) 180 / 78.5 PCD-D36: PWE-D36 or PWE-9 180 / 81.6 PCD-SC: CESC 85 / 38.5 PCD-SC-3X: CESC + CE-3X2 or CESC + CE-9X2 170 / 77.1 PCD-SC-3X-3G: CESC + CE-3X2 + CE-G 85 / 38.5 PCD-UPE3: UPE-3 or UPE-6 230 / 104.3 PCD-UPE4: UPE-4 or UPE-8 Dimensions H x W x D (in/mm) Weight (lb/kg) 36 x 38 x 3 / 914 x 965 x 76 36 x 64 x 3 / 914 x 1625 x 76 36 x 65 x 3 / 914 x 1625 x 76 36 x 90 x 3 / 914 x 2286 x 76 36 x 38 x 3 / 914 x 965 x 76 36 x 65 x 3 / 914 x 1625 x 76 29 x 58 x 3 / 736 x 1473 x 76 29 x 42 x 3 / 736 x 1066 x 76 27 x 44 x 3 / 685 x 1117 x 76 27 x 38 x 3 / 685 x 914 x 76 36 x 53 x 3 / 914 x 1346 x 76 36 x 79 x 3 / 914 x 2006 x 76 27 x 44 x 3 / 685 x 1117 x 76 27 x 44 x 3 / 685 x 1117 x 76 154 / 69.9 264 / 11.8 264 / 119.8 366 / 166 154 / 69.9 260 / 117.9 196 / 88.9 142 / 64.4 134 / 60.8 114 / 51.7 220 / 99.8 325 / 147.4 134 / 60.8 134 / 60.8 190 / 86.1 144 / 65 Pedestal Support Series Pedestal Support for UPE Enclosures >Three pedestal support systems for all UPE series applications >Universal cover is easily field-configured >Vaults for greater stability and cable slack storage >Provides space for sweeps to enter the enclosure Structural Foam Precast Enclosure Pedestals Models: PS-1: PS-2-ECR: PS-6: PS-6XL: UPE-3 UPE-4 UPE-6 UPE-6L UPE-8 - - - - UPE-M3 UPE-M6 UPE-M8 - - - Note: Meter load center and ECR through hole in PS6 cover is easily drilled through as required. Features Polyethylene Construction: Large Body Design: Flush Mount Enclosure Surface: Mounting Hardware: Eliminates the need for costly and time consuming concrete work Provides convenient working space for connections No enclosure distortion due to uneven concrete installations Included 49 Enclosure Options PCC-7K5: Dimensions H x W x D (in/mm) Generators Adding a generator to any type of power system provides additional peace of mind. For outside plant communication networks, a generator serves as assurance that even in severe conditions, you will be able to keep your system up and functioning. All AlphaGen™ systems are engineered to have significantly reduced noise levels, high power density and status monitoring. >AlphaGen Curbside Generator The AlphaGen curbside generator system is specifically designed for outside plant communication networks. Every AlphaGen system incorporates industry leading power technology, including: automated operation of natural gas or propane powered engine generators, exclusive audible noise baffling, remote status monitoring features and durable weather resistant enclosures. Alpha offers a full line of AlphaGen systems specifically designed for easy integration into various power supply designs. >AlphaGen DCX 3000 Portable Generator The Alpha generator family includes a portable 3.0kW DC generator. The compact, lightweight AlphaGen generator is designed specifically for powering cable television, telecommunications and other broadband applications that do not have integrated generators as a primary component of the power system. The portable generator incorporates several technological advantages including: ultra quiet operation, 36 or 48V selectable dual voltage output based on Permanent Magnet Generator (PMG) technology, 3000W of power and oversized fuel tank for up to 20 hours of runtime at 25% load or 7.2 hours at 100% load. Additional features include a convenient front 51 panel with a keyed on/off switch, output connector, output indicators, voltmeter, fuel valve and engine choke. >AlphaGen EU 2000 Portable Generator specially qualified for use in the GEM system. The EU 2000 can be quickly installed or removed from GEM enclosures, allowing for dynamic and flexible responses to power outages. >AlphaGen Portable Generator Trailer The AlphaGen Portable Generator Trailer, is a custom-designed trailer to store, transport and deploy 28 AlphaGen generators and accessories. The trailer is 16ft long, has a 10,000lb GVWR and is completely enclosed. For nighttime emergencies, the trailer includes battery-operated interior lighting. The battery is always fully charged by a maintenance free solar panel charger. The trailer sits on a 6 x 2 inch tubular steel frame and the trailer’s contents are protected with a patented corrosion protection system. The rugged, industrial-grade running gear includes dual Torflex rubber torsion axles with 16 inch radial tires, electric brakes, LED stop/tail/turn/marker lights and a 7-pin electrical connector. An adjustable height hitch includes DOT chains and choice of ball or pintle coupler. Generators The AlphaGen EU 2000 is a single cylinder, 4-stroke OHC, gasoline, portable AC generator AlphaGen™ Curbside Broadband Generator Systems >Cost-effective extended runtime solution for broadband powering applications >Quiet operation, small size and low profile allow for easy installation in populated areas >Eliminates the large quantities of batteries otherwise required for extended runtime AlphaGen CE3x2-3G AlphaGen Curbside Output Rating: 3.5kW 5.0kW 7.5kW 39V ±0.5V @ no load 36V configuration 39V ±0.5V @ no load 36V configuration 52V ±0.5V @ no load 48V configuration 52V ±0.5V @ no load 48V configuration 52 ±0.5V @ no load 48V configuration 104V ±0.5V @ no load 96V configuration DC Output Load Regulation: 0.5V 0.5V 0.5V Output Current: 39V @ 90A max. / 52V @ 67A max. 39V @ 128A max. / 52V @ 96A max. 52V @ 144A max. / 104V @ 72A max. DC Output Voltage: 398cc, Air cooled, Single OHV 10.5hp (using natural gas fuel) Engine: 2800 to 3600RPM RPM (Variable Speed): 2800 to 3600RPM 2800 to 3600RPM Acoustical Noise Generators 52 dBA 10' @ 100% Rated Load: 68.7 68.5 70.3 dBA 20' @ 100% Rated Load: 63 62.5 64.3 dBA 10' @ 70% Rated Load: 68.3 66.9 66.4 dBA 20' @ 70% Rated Load: 62.6 60.9 60.4 Models: CE-3x2 CE-9x2 CE-3x2 CE-9x2 PN-6x Dimensions H x W x D (in/mm): 44 x 26 x 24 / 1117.6 x 660.4 x 609.6 52 x 26 x 24 / 1320.8 x 660.4 x 609.6 44 x 26 x 24 / 1117.6 x 660.4 x 609.6 52 x 26 x 24 / 1320.8 x 660.4 x 609.6 39 x 39.3 x 24 / 914 x 998.2 x 609.6 (57 x 39.3 x 24 / 1447.8 x 998.2 x 609.6 with optional pedestal) Weight (lb/kg): 383 / 174 413 / 187 383 / 174 413 / 187 338 / 174 (370 / 168 with optional pedestal) APU Fuel Consumption Natural Gas (1000BTU/Ft.3): 60ft3/hr 80ft3/hr Propane Gas (2520BTU/Ft. ): 0.82gal/hr - 30ft /hr - 3.46lb/hr 1.10gal/hr - 40ft /hr - 4.62lb/hr 3 3 3 150ft3/hr 1.48gal/hr - 50ft3/hr - 6.24lb/hr 65°C / 149°F max (meets requirements of UL/CSA) Exterior Surface Temperature: All Models AlphaGen Configuration Options Gas Inlet Pressure: 0.5 to 2 PSI Inlet Pressure (Contact Alpha Engineering for additional supply resources) Ign Charger Voltage: 13.5Vdc Ign Charger Current: 6A max. Remote Interface Length: 75ft typical, distance depends upon installation, de-rating and wire gauge. Agency Compliance: UL1778, UL2200, NFPA 37/54/58 and 70, CSA C22.2 No.107.1, EMC/FCC Part 15 Class A Fuel System, Controls and Monitoring: The controls and fuel system meet applicable sections of NFPA 37, 54 and 58 for automatic unattended operation of remotely located generators. Full system control and status monitoring included. Sensors: Gas hazard, pad shear, water intrusion and tamper Safety Shutdowns: Low oil pressure, over temp, low fuel pressure shutdown (propane only), water intrusion, pad shear, gas hazard (propane or natural gas), over-speed, over-crank Optional Feature: Cold Start Kit: provides additional starting capability at temperatures below -18°C / 0°F CE-3x2 3.5 or 5kW CE-9x2 3.5 or 5kW CE-3/9G Propane Storage for Generator (For 3.5 and 5kW) PN-6x 7.5kW (PN-6x is not compatible with CE-3/9G) Portable AC and DC Generators For Disaster Recovery and Preparedness >DC technology requires no Automatic Transfer Switch (ATS) >No need to disconnect or reconnect power supply >Super quiet operation: only 58dBA at 22ft/7m AlphaGen DCX 3000 >Completely enclosed, water resistant >Oversized metal gas tank with fuel level gauge for extended runtimes of up to 20 hours AlphaGen EU 2000 AlphaGen™ DCX 3000 Part Number: 041-028-10 Optional Accessories Engine: Honda GX 200 6.5hp, air-cooled, OHV, single cylinder, manual recoil starting, manual choke DCX-PG-WK: Portable Generator Wheel Kit (P/N 745-793-20) DCX-PG-HANDLE: Locking Handle (P/N 745-792-20) Rated Power: 2800W continuous, 3000W max. AG-PG-TOOL: Punch Tool Kit for Enclosures (P/N 745-131-20) Alternator: Permanent magnet, brushless, bearingless AG-PG-UK: Enclosure Upgrade Kit (P/N 745-131-21) AG-CAB-KIT: Cable Bag With Cable and Key Lanyard (P/N 745-764-21-001) Dual Range Selector 36V: 39.5Vdc nominal at generator output connector 48V: 52.5Vdc nominal at generator output connector Output Regulation: 1Vdc Control Features: Automatic voltage regulation, electronic governor over current protection, analog voltmeter with back light Cable Interface: Anderson type SBE-80 connector Fuel Tank: 3.4g / 12.8ltr metal tank with level gauge Runtime 20hrs / 10hrs / 7.2hrs Noise: Approx. 58dBA @ 7m under full load Frame: Fully enclosed Dry Weight (lb/kg): Less than 118 / 53.5 Dimensions H x W x D (in/mm): 22.4 x 18.9 x 25.8 / 569 x 480 x 655 Agency: CSA C22.2 No. 100-95, 107.1-01, 107.2-M89, 0.4 FCC part 15B Class A Required Accessories Output Interface Cable (m/ft): Available in 3 / 10, 9.1 / 30 or 15.2 / 50 lengths Battery Interface Cable: Choose Ring Lung, Heavy-Duty Alligator Clamp, or Y-adapter* AlphaGen EU 2000 Specifications The AlphaGen EU 2000 is a single cylinder, 4-stroke OHC, gasoline, portable AC generator specially qualified for use in the GEM system. The EU 2000 can be quickly installed or removed from GEM enclosures, allowing for dynamic and flexible responses to power outages. Output Voltage: 120Vac Peak Rated Output: 2000VA Continuous Rated Output: 1600VA Noise Level: 53 to 59dBA Net Weight (lb/kg): 46.3 / 21 Runtime: 4 to 15hrs AC Line Transfer Switch (Optional): Can be connected to power supply using a Line Transfer Switch (LTS) to automatically switch power supply to generator power during outages. 53 30' Output Interface 10' P/N 875-324-22 30' P/N 875-324-20 50' P/N 875-324-21 Ring Lug Battery Interface P/N 874-946-21 Alligator Clamp Battery Interface P/N 874-946-20 Y-Adaptor Battery P/N 874-946-22 Generators @ 25% / 80% / 100% Load: Accessories * Connects the power supply’s battery input directly to the generator AlphaGen™ Portable Trailer Emergency Response and Disaster Recovery >Securely holds 28 AlphaGen portable DC generators >Designed for storage and transportation of gasoline powered generators >Generator hoist allows for single person deployment and recovery AlphaGen portable trailer >Customized 10,000lb trailer When an emergency arises, service operations need to respond immediately and the Alpha generator trailer enables them to do just that. These custom designed trailers eliminate generator storage and transportation issues, while increasing emergency preparedness. Designed to house, transport and deploy up to twenty-eight AlphaGen portable generators, these trailers are a proactive measure to ensure the necessary equipment 54 can be deployed immediately. Having the AlphaGen portable generators fueled and ready to transport at a moment's notice greatly reduces the duration of system outages, a critical Choice of towing coupler on adjustable-height mount - 3" Pintle Ring or 2-5/16" Ball Generators component of network reliability. 24” Aluminum tread plate stone guard with wrapped integrated corners Rear swing down ramp door with spring assist and non-skid surface AlphaGen™ Portable Trailer Emergency Response and Disaster Recovery >All welded steel construction with space for additional materials >Complete aluminum interior and diamond tread floor >Internal lighting for nighttime deployments >Bay lights and hoist powered by internal battery system with solar maintenance charger 55 Generators Portable generator racks securely hold 28 AlphaGen DCX3000 DC generators in transit All-welded steel construction with shelving for additional materials Generator hoist to raise and lower second shelf generators Heavy duty rails provide smooth movement of units through trailer AlphaCell® Batteries Ensure optimal performance for your outdoor broadband, cable television and telecommunications applications by incorporating AlphaCell batteries. With Alpha’s standby batteries, you don’t have to worry about leakage, frequent replacements or cycling to obtain 100% capacity. They come ready to support your network runtime expectations right out of the box. Whether it is the industry-leading warranty, increased runtimes or maintenance-free threaded inserts, expect optimum performance from AlphaCell batteries. >AlphaCell HP The AlphaCell HP brings pure lead technology to broadband power. Providing extended runtime and up to 20% extended life expectancy, AlphaCell HP is the premium choice for your network. AlphaCell 4.0 HP also provides potential operating expenditure reduction by reducing battery string counts in situational applications. >AlphaCell GXL Alpha’s standby battery offering incorporates true GelCell and Silver Alloy grid battery technologies, ensuring optimal performance for your outdoor cable, traffic or Wi-Fi application. AlphaCell batteries provide the ultimate warranty, longest runtimes and superior longevity in today’s demanding outdoor non-temperature controlled cable power environments. >AlphaCell AGM The AlphaCell batteries provide the ultimate warranties, the longest runtimes and the best longevity in today’s demanding outdoor non-temperature controlled environments. AlphaCell AGM 57 batteries are an economical option for broadband, traffic and other indoor/outdoor UPS applications. With a flame-arresting, one-way pressure-relief vent for safety and long life, and a classified as non-hazardous material and are not restricted for air, water or surface transport. >AlphaCell HPL-FT The AlphaCell HPL-FT series batteries are constructed from a high performance lead alloy with front terminals for use with Fiber Deep XM2-300HP and XM2-906HP power supply systems. These batteries include a central gassing system, snap-in front covers, integral flame arrestor and low self-discharge rates. >AlphaGuard™ The AlphaGuard monitors and protects your batteries by spreading the charge voltage equally across all batteries in the string, ensuring that every battery is properly charged. With an ideal voltage across each battery, life and runtime are optimized. Individual batteries in a string can be replaced as they fail, allowing good batteries to be left in service longer. This stops the wasteful and costly practice of replacing complete battery strings based on a single battery failure. >Battery Testing Equipment A fast, reliable and affordable testing process is now available with the development of conductance based battery measurement technology. By coupling conductance testing with a simple system load or voltage test, the system operator is armed with the quality of data necessary to know the status of their installed standby batteries and budget replacements with confidence. AlphaCell Batteries thermally welded case-to-cover bond to ensure a leak-proof seal, Alpha’s AGM batteries are AlphaCell® 3.5HP and 4.0HP Pure Lead Batteries >Pure lead technology provides up to 20% increased life expectancy >Up to 6-year full warranty with XM3-HP >Non-spillable UN2800 rating for ease of transportation >4.0HP offering 240 cable runtime minutes >String Count Reduction to Reduce OpEx AlphaCell 3.5 and 4.0HP You can use fewer AlphaCell HP batteries compared to standard batteries, while maintaining network runtime reliability. For power supply loads that are less than 8 Amps you can achieve a 4 hour runtime using a single string of 4.0HP batteries, compared to using two strings of competitive batteries. Consult your Alpha sales engineer for a free network analysis on how to potentially reduce your OpEx by up to 25 percent while increasing the reliability of the batteries in your network. AlphaCell 3.5HP and 4.0HP Models: 3.5HP 4.0HP Specifications 1 AlphaCell Batteries 58 Warranty: 5 to 6 year full replacement 5 to 6 year full replacement Service Life: Extended Extended Typical Runtime (minutes)2: 210 240 Sealed VRLA: Valve regulated lead acid Valve regulated lead acid Heat Resistant: Extreme Extreme Hydrogen Emission: Low Low Terminals: Threaded insert 1/4" - 20 UNC Threaded insert 1/4" - 20 UNC Electrical Cell per Unit: 6 6 Voltage per Unit: 12.8 12.8 Conductance Value: 1700 2100 Max. Discharge Current (A): 800 900 Short Circuit Current (A): 2800 3200 10 Second Volts @ 100A: 11.7 11.8 Ohms Impedance 60Hz: 2.7 2.2 BCI Group Size: 31 31 Mechanical Dimensions H x W3 x D3 (in/mm): 8.5 x 13.4 x 6.8 / 223.5 x 337.8 x 172.7 8.5 x 13.4 x 6.8 / 223.5 x 337.8 x 172.7 Weight (lb/kg): 68 / 30.8 74 / 35.6 Discharge: -40 to 60°C / -40 to 140°F -40 to 60°C / -40 to 140°F Charge (with Temp compensation): -40 to 60°C / -40 to 140°F -40 to 60°C / -40 to 140°F Float Charging Voltage (Vdc): 13.5 to 13.8 13.5 to 13.8 Operating Temperature Range 0.5% RMS or 1.5% of float charge voltage recommended for best results. Max. allowed = 4%V pk to pk AC Ripple Charge: Notes: 1 See AlphaCell Users Guide for additional details 2 Runtimes calculated using a 25A DC constant current load to 1.75Vdc @ 25°C 3 Dimensions at top of battery AlphaCell HP Current Discharge Ratings in Amps Hours* 3.5HP 4.0HP End Voltage 1.75VPC: 1 2 3 4 8 10 20 70.2 40.3 28.6 22.3 12.1 9.9 5.2 End Voltage 1.70VPC: 72.0 41.1 29.2 22.7 12.3 10.0 5.3 End Voltage 1.75VPC: 81.9 45.8 32.2 25.0 13.1 10.6 5.7 End Voltage 1.70VPC: 83.7 46.7 32.8 25.4 13.3 10.7 5.8 AlphaCell HP Amp Hour Ratings Hours* 3.5HP 4.0HP End Voltage 1.75VPC: 1 2 3 4 8 10 20 70.2 80.6 85.8 89.2 96.8 99.0 104.0 End Voltage 1.70VPC: 72.0 82.2 87.6 90.8 98.4 100.0 106.0 End Voltage 1.75VPC: 81.9 91.6 96.6 100.0 104.8 106.0 114.0 End Voltage 1.70VPC: 83.7 93.3 98.3 101.5 106.3 107.0 115.8 * Use hours column above which closest models your desired runtime AlphaCell® HP Runtime Pure Lead Batteries >3 to 5 times longer shelf life vs. standard VRLA >Provides up to 50% increased runtime in coldest climatesEfficiency VS. Temperature AlphaCell 3.5HP and 4.0HP 100% 2.16 OCV Per Cell 90% 2.14 85% 2.13 80% 2.12 75% 2.11 2.1 Percent State of Charge 95% 2.15 40°C / 104°F 0 3 6 30°C / 86°F 9 12 25°C / 77°F 15 18 21 20°C / 68°F 70% 24 100% Percent Rated Capacity Available 2.17 80% 60% 3.5HP 40% Typical Gel 20% 0% Storage Time (Months) 4.0HP -40°F/ -40°C -22°F/ -30°C -4°F/ -20°C 14°F/ -10°C 32F/ 0°C 50°F/ 10°C 68°F/ 20°C 86°F/ 30°C 104°F/ 40°C AlphaCell HP Runtime XM3-HP (minutes) 90Vac @ 4A Model: 3.5HP 4.0HP 3.5HP 4.0HP 3.5HP 4.0HP 3.5HP 4.0HP 3 batteries: 540 588 358 394 263 295 204 234 1264 771 841 574 624 450 491 6 batteries: 1144 90Vac @ 12A 6A 8A 14A 10A 16A Model: 3.5HP 4.0HP 3.5HP 4.0HP 3.5HP 4.0HP 3 batteries: 165 193 137 164 116 142 6 batteries: 368 404 308 342 264 295 59 AlphaCell HP Runtime XM2-915, XM2-922 and GMX Runtime (minutes) 4A Model: 3.5HP 4.0HP 6A 3.5HP 4.0HP 8A 3.5HP 4.0HP 3.5HP 4.0HP 3 batteries: 490 533 310 344 229 260 182 211 4 batteries: 672 732 429 469 320 353 255 286 6 batteries: 1041 1146 672 732 504 548 404 442 8 batteries: 1413 1576 917 1006 691 752 556 605 9 batteries: 1601 1795 1041 1146 785 875 632 688 90Vac @ 12A 14A 10A 16A 18A Model: 3.5HP 4.0HP 3.5HP 4.0HP 3.5HP 4.0HP 3.5HP 4.0HP 3 batteries: 146 174 118 144 100 124 87 109 4 batteries: 206 236 167 195 142 170 123 150 6 batteries: 329 363 268 300 229 260 200 230 8 batteries: 454 495 372 408 320 353 279 311 9 batteries: 518 563 424 463 365 401 320 353 Above calculations based on an AC load with a .92 cable plant power factor 60Vac @ 4A Model: 3.5HP 4.0HP 6A 3.5HP 4.0HP 8A 3.5HP 4.0HP 3.5HP 4.0HP 3 batteries: 746 833 490 533 365 401 291 324 4 batteries: 1041 1146 672 732 504 548 404 442 6 batteries: 1601 1795 1041 1146 785 857 632 688 8 batteries: 2165 2465 1413 1576 1069 1178 864 946 9 batteries: 2448 2806 1601 1795 1212 1343 981 1078 60Vac @ 12A 14A 10A 16A 18A Model: 3.5HP 4.0HP 3.5HP 4.0HP 3.5HP 4.0HP 3.5HP 4.0HP 3 batteries: 236 267 192 221 164 192 142 170 4 batteries: 329 363 268 300 229 260 200 230 6 batteries: 518 563 424 463 365 401 320 353 8 batteries: 709 773 583 635 504 548 442 482 9 batteries: 806 881 664 723 573 624 504 548 Above calculations based on an AC load with a .92 cable plant power factor AlphaCell Batteries 90Vac @ AlphaCell® GXL GelCell Batteries >True Gel Silver Alloy minimizes grid corrosion >Maintenance-free threaded inserts — no periodic retorquing >Full-replacement, non-prorated warranty AlphaCell 195 and 220 GXL AlphaCell Broadband Batteries AlphaCell Batteries 60 Models: 220 GXL 195 GXL 165 GXL 85 GXL-HP 195 GXL-FT Warranty: 4 years 4 years 4 to 5 years 5 years 2 to 3 years Service Life: Extended Extended Extended Extended Long Runtime (minutes)1: 221 196 165 85 195 VRLA Battery Type: Gel Silver Alloy Gel Silver Alloy Gel Silver Alloy Gel Silver Alloy Gel Heat Resistant: Extreme Extreme Extreme Extreme High Hydrogen Emission: Low Low Low Low Low Terminals: Threaded insert 1/4" - 20 UNC Threaded insert 1/4" - 20 UNC Threaded insert 1/4" - 20 UNC Threaded insert 10 - 32 UNF 16mm insert M6 thread Cells Per Unit: 6 6 6 6 6 Voltage Per Unit: 12.8 12.8 12.8 12.8 12.8 Max. Discharge Current (A): 900 900 800 600 400 Short Circuit Current (A): 2800 2600 2500 2200 3000 10 Second Volts @ 100A: 11.4 11.3 11.2 10.8 10.8 Ohms Impedance 60Hz: 0.0050 0.0050 0.0055 0.0065 .0041 BCI Group Size: 31 31 27 22 N/A Weight (lb/kg): 73 / 33.2 67 / 30.5 63 / 28.6 39.6 / 18 76.3 / 34.5 Dimensions H x W2 x D2 (in/mm): 8.5 x 13.4 x 6.8 / 215 x 341 x 173 8.5 x 13.4 x 6.8 / 215 x 341 x 173 8.1 x 12.5 x 6.8 / 205 x 318 x 173 8.1 x 9 x 5.5 / 206 x 228 x 139 11.2 x 4.3 x 15.6 / 285 x 110 x 395 Operating Temperature Range Discharge: -40 to 71°C / -40 to 160°F -40 to 71°C / -40 to 160°F -40 to 71°C / -40 to 160°F -40 to 71°C / -40 to 160°F -40 to 71°C / -40 to 160°F Charge (w/ temp compensation): Float Charging Voltage @ 25°C / 77°F (Vdc): AC Ripple Charge: -23 to 60°C / -9.4 to 140°F -23 to 60°C / -9.4 to 140°F -23 to 60°C / -9.4 to 140°F -23 to 60°C / -9.4 to 140°F -20 to 50°C / -4 to 122°F 13.5 to 13.8 13.5 to 13.8 13.5 to 13.8 13.5 to 13.8 13.6 to 13.8 0.5% RMS or 1.5% of float charge voltage recommended for best results. Max. allowed = 4%V pk to pk Notes: 1 Runtimes calculated using a 25A DC constant current load with voltage discharge to 1.75V/cell @ 25°C / 77°F. 195GXL-FT runtime at 25A to 1.75VPC @ 25°C / 77°F. 10 cycles required to obtain maximum runtime charge 2 Dimensions at top of battery except for 195GXL-FT dimensions at battery base AlphaCell GXL Current Discharge Ratings in Amps (End Voltage 1.75VPC) Hours* 1 2 3 4 8 10 20 220GXL: 66.1 39.6 28.5 22.4 12.3 10.0 5.4 195GXL: 61.2 35.2 25.2 19.7 10.8 8.9 5.0 165GXL: 55.9 32.8 23.5 18.4 10.0 8.2 4.3 85GXL: 33.2 18.8 13.3 10.4 5.7 4.6 2.5 AlphaCell GXL Amp Hour Ratings (End Voltage 1.75VPC) Hours* 1 2 3 4 8 10 20 220GXL: 66.2 79.2 85.5 89.6 98.4 100.0 109.0 195GXL: 61.2 70.4 75.6 78.8 86.4 89.0 100.0 165GXL: 55.9 65.6 70.5 73.6 80.0 82.0 86.0 85GXL: 33.2 37.6 39.9 41.6 45.6 46.0 50.0 * Use hours column above which closest models your desired runtime. AlphaCell® GXL Runtime GelCell Batteries >Provides maximum runtime over the life expectancy of the battery >100% out-of-box capacity — no cycling required >Industry leading runtime for VOIP networks AlphaCell 165 GXL XM3-HP Runtime (minutes) 90Vac @ Model: 4A 195GXL 220GXL 6A 195GXL 220GXL 8A 195GXL 220GXL 10A 195GXL 220GXL 12A 195GXL 220GXL 14A 195GXL 220GXL 16A 195GXL 220GXL 3 batteries: 6 batteries: 476 1026 550 1177 313 685 363 789 229 506 265 585 177 396 205 458 142 322 164 373 118 269 136 311 99 229 115 266 XM2-915, XM2-922 and GMX Runtime (minutes) 90Vac @ Model: 4A 220 195 165 6A 220 195 165 8A 220 195 165 10A 220 195 165 3 batteries: 4 batteries: 6 batteries: 8 batteries: 9 batteries: 508 701 1091 1487 1686 453 625 978 1338 1519 396 546 853 1165 1322 320 444 701 960 1091 285 396 625 859 978 249 346 546 750 853 236 329 523 720 820 209 293 465 643 733 193 256 407 562 640 186 261 418 577 659 165 232 372 515 587 144 203 325 450 514 90Vac @ Model: 12A 220 195 165 14A 220 195 165 16A 220 195 165 18A 220 195 165 3 batteries: 4 batteries: 6 batteries: 8 batteries: 9 batteries: 149 210 339 478 538 132 187 301 419 479 115 163 264 367 419 119 169 275 385 440 106 151 245 341 391 92 132 214 299 342 101 144 236 329 377 89 128 209 293 335 77 112 183 256 294 87 124 204 288 329 78 111 182 255 293 66 96 159 223 256 61 Above calculations based on an AC load with a .92 cable plant power factor 4A 220 195 165 6A 220 195 165 8A 220 195 165 10A 220 195 165 3 batteries: 4 batteries: 6 batteries: 8 batteries: 9 batteries: 798 1091 1686 2288 2590 712 978 1519 2067 2345 622 853 1322 1798 2037 508 701 1091 1487 1686 453 625 978 1338 1519 396 546 853 1165 1322 377 523 820 1122 1273 335 465 733 1006 1143 294 407 640 877 997 300 418 659 904 1027 267 372 587 809 921 233 325 514 706 803 60Vac @ Model: 12A 220 195 165 14A 220 195 165 16A 220 195 165 18A 220 195 165 3 batteries: 4 batteries: 6 batteries: 8 batteries: 9 batteries: 242 339 538 741 843 215 301 479 660 753 188 264 419 577 658 196 275 440 607 692 174 245 391 541 617 151 214 340 470 538 166 236 377 523 597 148 209 335 465 531 125 182 290 402 462 144 204 329 458 523 128 182 293 407 465 107 155 252 351 402 AlphaCell Batteries 60Vac @ Model: Above calculations based on an AC load with a .92 cable plant power factor XM2-300HP Runtime (minutes) XM2-906HP Runtime (minutes) Estimated Runtime 1A 2A 3A 4A 5A 6A 7A 8A XM2-300 @ 90V 1A 1.5A 2A 2.5A 3A 85 GXL, 60V Runtime: 948 576 444 342 264 222 186 162 AlphaCell 70 HPL-FT: 249 167 120 91 71 85 GXL, 90V Runtime: 600 366 276 216 168 138 - - AlphaCell 85 GXL: 332 212 150 113 89 70 HPL, 60V Runtime: 774 474 366 282 228 186 168 138 AlphaCell 195 GXL: 684 442 317 241 191 70 HPL, 90V Runtime: 498 300 228 180 138 114 - - AlphaCell 4.0HP: 840 547 398 308 251 Runtimes based on one battery 115 HPL, 60V Runtime: 1200 756 582 456 354 300 252 222 115 HPL, 90V Runtime: 762 486 366 288 222 186 - - With XM2-906 and three batteries installed, * Note: Battery temperature = 25°C / 77°F, Load PF = 0.92, Accuracy: 0.25 hour AlphaCell 195 GXL-FT Runtime Specifications (minutes) AlphaCell 195 GXL-FT Runtime Specifications (minutes) XM2 90Vac @ 6A 8A 10A 12A 14A 16A 18A 20A XM2 60Vac @ 6A 8A 10A 12A 14A 16A 18A 20A 3 batteries: 283 195 153 123 100 85 76 67 3 batteries: 467 325 246 195 163 142 123 107 4 batteries: 404 280 211 170 145 123 105 91 4 batteries: 648 467 353 281 230 194 170 153 6 batteries: 662 467 353 281 230 194 170 153 6 batteries: 1077 789 576 461 386 325 280 245 8 batteries: 960 654 501 403 331 280 242 211 8 batteries: 1447 993 847 654 541 461 403 353 Runtimes calculated using a 25A DC constant current load with voltage discharge to 1.75V/cell @ 25°C / 77°F Runtimes calculated using a 25A DC constant current load with voltage discharge to 1.75V/cell @ 25°C / 77°F AlphaCell® Specialty Batteries >AGM runtimes up to 160 minutes in outdoor cable applications >Absorbent Glass Mat (AGM) technology for efficient gas recombination >HPL-FT features front terminal design with protective covers >Specifically designed for mission critical applications AlphaCell 220HPL-FT AlphaCell AGM Batteries AlphaCell HPL-FT Batteries Models: 135 AGM-P 170 XLT Models: 70HPL-FT 115HPL-FT 220HPL-FT Warranty1: 4 year full replacement 1 year full replacement Standard Warranty1: 3 years 3 years 3 years Service Life: Long Average Service Life: Long Long Long Runtime (minutes)2: 135 170 Runtime (minutes)2: 70 115 220 VRLA Battery Type: AGM AGM VRLA Battery Type: Heat Resistant: High to moderate Moderate Heat Resistant: High High High Hydrogen Emission: Low Low Hydrogen Emission: Low Low Low Terminals: AlphaCell Batteries 62 Threaded insert 1/4" - 20 UNC High performance Lead Alloy Terminals: 14mm Insert M8 x 1.25 thread Cells Per Unit: 6 6 Terminal Torque: 8Nm 8Nm 8Nm Voltage Per Unit: 12.8 12.8 Case Material: VO VO VO Max. Discharge Current (A): 800 800 Cells Per Unit: 6 6 6 Short Circuit Current (A): 3100 3300 12.8 12.8 12.8 10 Second Volts @ 100A: 11.5 11.6 Ohms Impedance 60Hz: 0.005 0.004 1000 1000 1000 Capacity at 20hrs (to 1.75VPC): 75Ah 88Ah 1400 2000 3500 BCI Group Size: 24 27 Weight (lb/kg): 54.8 / 24.9 62 / 28 Voltage Per Unit: Max. Discharge Current (A): Short Circuit Current (A): 10 Second Volts @ 100A: 11.3 11.5 11.7 Ohms Impedance 1kHz: 6.5mOhms 4.1mOhms 2.5mOhms Capacity @ 20hrs to 1.75VPC): 42Ah 62Ah 107Ah Weight (lb/kg): Dimensions H x W3 x D3 (in/mm): 27.9 / 15.3 8.21 x 3.81 x 9.84 / 209 x 97 x 250 46.2 / 22.2 10.3 x 4.2 x 11.3 / 263 x 103 x 287 78.5 / 36 11.3 x 4.2 x 15.6 / 36 x 108 x 396 Dimensions H x W3 x D3 (in/mm): 8.02 x 10.26 x 6.83 / 203.6 x 260.5 x 173.4 Operating Temperature Range Discharge: -40 to 71°C / -40 to 160°F Charge (with temp compensation): -23 to 60°C / -9.4 to 140°F Float Charging Voltage @ 25°C / 77°F (Vdc): AC Ripple Charger: 13.5 to 13.8 13.5 to 13.8 0.5% RMS or 1.5% of float charge voltage recommended for best results. Max. allowed = 4%V pk to pk Operating Temperature Range Discharge: Charge (with temp compensation): Float Charging Voltage @ 25°C / 77°F (Vdc): AC Ripple Charger: -40 to 60°C / -40 to 140°F -40 to 60°C / -40 to 140°F 13.5 to 13.6 13.5 to 13.6 13.5 to 13.6 0.5% RMS or 1.5% of float charge voltage recommended for best results. Max. allowed = 4%V pk to pk Notes: 1 Warranty varies by country and region. Consult your sales person for details 2 Runtimes calculated using a 25A DC constant current load with voltage discharge to 1.75V/ cell @ 25°C / 77°F 3 Dimensions at top of battery Notes: 1 Warranty varies by country and region. Consult your sales person for details 2 Runtimes calculated using a 25A DC constant current load with voltage discharge to 1.75V/ cell @ 25°C / 77°F 3 Dimensions at top of battery AlphaGuard™ Battery Charge Management System >Maximizes battery life >Spreads charge voltage equally across batteries >Compensates for battery differences as they age AlphaGuard CMT-3 >Replace single batteries, not the entire string >Single battery connections for charge management and status monitoring >Safe unattended operation designed to CSA C22.2 No. 107.1 and UL 1778 Standards >Optional potted AlphaGuard for underground battery vault applications Potted AlphaGuard CMT-3 AlphaGuard Models: Electrical Batteries: Individual 12Vdc nominal batteries configured into 36 or 48Vdc strings AlphaGuard Charge Management SC, 48V —including 48Vdc battery string interface cable Circuit Protection: Fast blow fuse, reverse polarity protected Quiescent Current Draw: 1mA max. (Current consumed by AlphaGuard after low voltage total shutdown) One (1) AlphaGuard is required per battery string Charge Management: Most effective during float period of charge With the battery string Max. Current: 2A @ 25°C / 77°F Quality of Final Balance: ±100mV max. between any two (2) batteries Charging Efficiency: 80 to 90% Charge Balance: ±100mV typical Low Voltage Cutoff: 34.5Vdc/46Vdc ±5% Communication to XM2: AG-DSM cable supplies battery readings to a DSM status monitoring card ±100mV AG-CMT-3: AlphaGuard Charge Management SC, 36V —including 36Vdc battery string interface cable AG-CMT-4: Configuration Quantity: Service Location: Mechanical Housing Material: High impact plastic Dimensions H x W x D (in/mm): 1.4 x 4.8 x 4.3 / 36 x 122 x 108 Weight (lb/kg): 0.8 / .36 Environment -40 to 55°C / -40 to 131°F Voltage Sense Regulation: Humidity 5 to 95% non-condensing Cables 5 years AG-DSM-S9-Cable, AG-DSM-D9-Cable, AG-DSM-D35-Cable, AG-DSM-S35-Cable, Battery Cable 36V 6ft, Battery 48V 6ft Warranty Warranty: Battery Accessories Operating Temperature: Battery Testing Equipment AlphaCell® Battery Testing Equipment >Complete battery life trending through conductance tests >Non-intrusive conductance measurements do not reduce string life >Quick, accurate measurements and data recording reduce on-site time >Simple pinpoint testing requires only access to two battery posts or straps >Enables early detection of questionable batteries in the network Celltron Essential CTE-1200AT Battery Testing Equipment Model: Celltron Essential Celltron Advanced™ Environment Model Number: CTE-1200AT (w/temp. sensor) CTA-4000 (kit) CTA-2000 (analyzer only) Operating Temperature: 0 to 40°C / 32 to 104°F Humidity: 95% non-condensing Tests 6 and 12V batteries with data retention Tests individual lead acid cells or monoblocs (up to 16V) in any common configurations Applications: Voltage: 1.5 to 20Vdc 1 to 20Vdc Conductance: 100 to 9999 Siemens 100 to 19990 Siemens Test Data Storage: Up to 144 consecutive tests can be stored internally 16 string locations of 480 test results stored internally Accuracy: +2% across test range +2% across test range Voltmeter Resolution: 10mVdc 5mVdc 63 Kit Contents Celltron Essential CTE-1200AT Celltron Advanced Kit CTA-4000AT Contains: CTE-1200AT tester PowerSure Software Infrared PC data cable Contains: Protective boot Rechargeable battery pack Infrared PC data receiver and software Infrared printer Infrared temperature sensor Protective carrying case Both clamp and probe cables Spare fuses, printer paper, probe tips 12V FlexPoint AX Series Indoor/Outdoor Hybrid Solution 12V FlexPoint AX Series Full Outdoor Solution Operator Accessible Battery Operator Accessible Utility Meter and Meter Base BBPS Indoor Home Converter 10.5 to 14Vdc 5-24 Watts Typical Output AC to DC Power Converter BBPS ONT Power & Remote Alarms 10.5 to 14Vdc 5-24 Watts Typical Output Fiber Voice, Video and Data Enters Through Wall 11.6 to 16Vdc Three Conductor Low Voltage DC ONT Power & Remote Alarms Fiber Voice, Video and Data Enters Through Wall 11.6 to 16Vdc Three Conductor Low Voltage DC Ground Rod Ground Rod 48V FlexNet FMPS Series Indoor Solution 48V FlexNet MPS Series Indoor Solution Operator Accessible Battery Indoor MPS 42 to 56Vdc 50 Watts Typical Output Operator Accessible Battery ONT Power & Remote Alarms 90 to 132Vac Fiber Voice, Video and Data Indoor ONT Fiber Voice, Video and Data Power & Remote Alarms 90 to 320Vac Ground Rod FMPS 42 to 58Vdc 150 Watts Typical Output ONT Fiber Voice, Video and Data Ground Rod Fiber Power Alpha Technologies offers a complete portfolio of Fiber-To-The-Home powering options with the FlexPoint™ line of 12Vdc single-family unit solutions (SFU), and the FlexNet™ line of 48Vdc multiple dwelling unit (MDU) and small office home office (SOHO) power supplies. All of Alpha’s powering solutions are engineered to perform reliably in the most demanding environmental conditions while optimizing battery life and performance. 12Vdc Solutions >FlexPoint 1207-F for RFoG Applications The indoor FlexPoint 1207, 7 Watt, 12Vdc standby power supply is an environmentally-hardened standby power supply intended to be placed indoor or outdoor in sheltered locations. Its compact size allows placement in the most densely populated structured medial enclosures. The FP1207 includes a unique emergency battery reserve function that provides greater lifeline service availability by preserving 25% of the usable battery capacity for user initiated emergency telephone calls. User interfaces include visual status indicators, audible alarms, silence alarm button and an auxiliary 12Vdc power input port allowing additional battery capacity to be added for longer standby runtimes. >Integrated Fiber Enclosure (IFE) The FlexPoint IFE-A30-1 Integrated Fiber Enclosure from Alpha Technologies provides a reliable, compact and cost-effective means to simplify RFoG deployment. The enclosure contains a fiber management system, an 8-way coaxial splitter and a FlexPoint power supply with provisions for installing RFoG devices. The door-mounted FlexPoint power supply provides 20 hours of battery backup runtime. The enclosure is lockable, making this system a secure and convenient solution for Micro Node management. >FlexPoint AX Series for EPON/GPON and RFoG 48Vdc Solutions >FlexNet MPS48-7 Series Alpha extends its family of FlexNet element powering solutions to include the MPS48-7F and MPS48-7T multipurpose power supplies. The MPS48-7F supports fiber-to-the-home applications including MDU, MTU and SBU ONT products. The MPS48-7T supports critical network communication loads. These units are indoor or outdoor, wall or pole mounted microprocessor controlled UPS systems providing 50 Watts of 48Vdc. The input is powered from 120, 240 or higher AC voltages with an optional step-down transformer. A 48Vdc string of standard 7.2Ah maintenance free sealed lead acid batteries provide standby power. >FlexNet FMPS The FTTx Multipurpose Power Supply (FMPS) is an indoor/outdoor system providing 150W of 48Vdc power to MDU and SOHO optical network terminals. The FlexNet FMPS is an environmentally hardened wall mount enclosure system with dual ONT connections supported with one or two 48Vdc strings of 7.2Ah batteries. The system includes one or two parallel outputs and alarm connections, supporting distances of up to 100ft between the FMPS and ONT, allowing the FMPS to be located close to existing power outlets. >FlexNet FiberUPS® The FlexNet FiberUPS is a 300W, 48Vdc battery backup power module supporting a variety of indoor and outdoor applications. With pole, wall or ground mount enclosure options, the FlexNet FiberUPS will keep field distributed electronics up and running during power disturbances and outages. >PMR and GMR Series The PMR and GMR series are comprised of two sizes of pole mount and two sizes of ground mount factory configured and regulatory certified rainproof enclosure systems. PMR and GMR are highly configurable systems including 19" adjustable or pullout swing racks, AC service entrance and distribution, surge suppression, fiber management, power bypass cabling, FiberUPS DC power supply, DC distribution and 50Ah AlphaCell® batteries. 65 Fiber Power Systems The indoor/outdoor FlexPoint AX Series, 30 Watt, 12Vdc fiber-to-the-premises optical network terminal (ONT) power supply system, provides network operators a highly reliable, scalable set of solutions for full or partial outdoor RFoG and PON installations. This system provides service technicians 24/7 access to the power system. FlexPoint AX home converters and power ring converters provide 12Vdc support for indoor and outdoor applications not requiring standby power. As services expand to include voice or critical data support, 7.2 or 17Ah battery backup power supplies (BBPS) can be easily added. FlexPoint™ 12Vdc RFoG Battery Back Up Power Supplies >Supports expanding services >Indoor and outdoor applications >24-Hour operational access to outdoor solutions >Safe, low-voltage distribution AX HC/BBPS-F 1207-F 7W RFoG System with Primary and Standby Power Specifications FPR1207-F7.2 — Indoor 12V 7W Power System Input: 85 to 264Vac (45-66Hz) Output Voltage: 10.5 to 14.4Vdc Output Power: 7 Watts Number of Batteries: One 7.2Ah battery Battery Backup Runtime: Approx. ~ 20hrs w/ 3.5W load, Approx. ~ 12hrs w/ 7W load Status Indicators: Visual and audible Dimensions H x W x D (in/mm): Weight (lb/kg): 66 7.75 x 8.75 x 3 / 177 x 224 x 76.2 Unit 1.3 / 0.59 Battery 5.7 / 2.6 Backup Power for Business Service RFoG Deployment Integrated Fiber Enclosure (IFE) — For RFoG Deployment Fiber Power Systems Specifications Battery Backup Runtime: Approx. ~ 20hrs w/ 3.5W load, Approx. ~ 12hrs w/ 7W load Coaxial Management: 8-Way Coax Splitter Fiber Management: Fiber wrap spool 12-fiber splice tray Features: Lockable, secure indoor enclosure Dimensions H x W x D (in/mm): 12 x 12 x 8 / 304.8 x 304.8 x 203.2 Weight (lb/kg): 8 / 3.6 AX 30W RFoG System with Primary and Standby Power AX HC/BBPS-F — Outdoor 12V 30W Power System Specifications Input: 85 to 132Vac Output Voltage: 10.5 to 14.4 Vdc Output Power: 30 Watts Mounting: Partial outdoor BBPS-F Dimensions H x W x D (in/mm): 7.75 x 8.75 x 3 / 177 x 224 x 76.2 Weight (lb/kg): 3 / 1.4 Home Converter Dimensions H x W x D (in/mm): 8.5 x 3 x 2 / 21.5 x 7.6 x 5 Home Converter Weight (lb/kg): 1 /.45 Home Converter Application AX RFoG Indoor Powering - UPS Operational Temperature Indoor Range: -40 to 113°F (-40 to 45°C Operational Temperature Outdoor Range: -40 to 113°F (-40 to 45°C) RFoG Device BBPS-F FlexPoint™ AX 12Vdc PON Battery Back Up Power Supplies >Full or partial outdoor configurations >Outdoor rated BBPS including battery for 24/7 availability >Utility meter base provides most reliable source of AC power at home FlexPoint AX Series AX 30W EPON/GPON System with and without Standby Power Specifications AX PC/BBPS — Outdoor 12V 30W System Input: 170 to 264Vac Output Voltage: 10.5 to 14.4Vdc Output Power: 30 Watts Mounting: Outdoor BBPS Dimensions H x W x D (in/mm): 7.75 x 8.75 x 3 / 177 x 224 x 76.2 Weight (lb/kg): 3 / 1.4 Power-Ring Dimensions H x Dia (in/mm): 4.75 x 7 / 120 x 178 Power-Ring Weight (lb/kg); 1.5 / 0.68 Power Converter Dimensions H x W x D (in/mm): 8 x 2 x 2 / 209 x 51 x 51 Power Converter Weight (lb/kg): 0.7 / 0.32 Power-Ring Home Converter BBPS 67 Applications AX PON Outdoor Powering – Non-UPS AX PON Outdoor Powering – UPS Operational Temperature Outdoor Range: -40 to 45°C / -40 to 113°F AX 30W EPON/GPON System with and without Standby Power Specifications AX HC/BBPS — Indoor / Outdoor 12V 30W Power System Input: 85 to 132Vac Output Voltage: 10.5 to 14.4Vac Output Power: 30 Watts Mounting: Partial outdoor BBPS Dimensions H x W x D (in/mm): 7.75 x 8.75 x 3 / 177 x 224 x 76.2 Weight (lb/kg): 3 / 1.4 Home Converter Dimensions H x W x D (in/mm): 8.5 x 3 x 2 / 21.5 x 7.6 x 5 Home Converter Weight (lb/kg): 1 /.45 Home Converter BBPS Applications AX PON Indoor Powering – Non-UPS Operational Temperature Range: -40 to 45°C / -40 to 113°F AX PON Indoor Powering – UPS Operational Temperature Indoor Range: -40 to 45°C / -40 to 113°F Operational Temperature Outdoor Range: -40 to 45°C / -40 to 113°F Fiber Power Systems Operational Temperature Outdoor Range: -40 to 45°C / -40 to 113°F FlexNet™ 48Vdc 50W Battery Back Up Power Supplies >Rugged outdoor or indoor 48Vdc 50W wall or pole mount UPS >Aesthetically pleasing, minimizes presence in public locations >Optional compensated battery charging for optimum battery life >Local and remote status monitoring and reporting FlexNet MPS48-7 Series FlexNet MPS48-7 Series FN50-48-7F — With Output Interface Module-F Specifications Fiber Power Systems 68 Input: 90 to 132 or 180 to 264Vac Output Voltage: 42 to 56Vdc Output Power: 50 Watts continuous Output Interface Module-F: Packet Cable Alarms Output Interface Module-T: Dry Contact Alarms Unit Dimensions H x W x D (in/mm): 4.18 x 8.75 x 2.12 / 106.17 x 222.25 x 53.84 Weight (lb/kg): 1.5 / 0.68 System Dimensions H x W x D (in/mm): 17.5 x 12.75 x 5.25 / 445 x 324 x 133 Weight (lb/kg): 11 / 4.9, 34.6 / 15.7 w/ batteries Number of Batteries: Four 7.2Ah Valve Regulated Lead Acid (VRLA) Runtime: 18 Hours @ 20W load, 8 Hours @ 40W load FN50-48-7T — With Output Interface Module-T FlexNet™ 48Vdc 150W Battery Back Up Power Supplies >FTTP outdoor UPS for Multiple Dwelling, Multiple Tenant and Small Business Unit applications >Battery management performs periodic battery capacity testing and status reporting to the ONT and customer >Battery heater option provides extended runtime for applications in cold weather conditions >Status indicators and audible alarm provide local reporting FlexNet FMPS FLexNet FMPS Specifications Input: 90 to 320Vac Output Voltage: 42 to 58Vdc Output Power: 150 Watts continuous FMPS Dimensions H x W x D (in/mm): 23.75 x 14 x 5.5 / 603.25 x 355.6 x 139.7 Weight (lb/kg): 25 / 11.3 Number of Batteries: Four or eight 7.2Ah Valve Regulated Lead Acid (VRLA) FlexNet™ 48Vdc 300W Battery Back Up Power Supplies >300W 48Vdc UPS for outdoor or indoor applications >Power modules can be used in a variety of Alpha enclosures >Temperature compensated battery charging for extended battery life FlexNet ELPM-300 >Flexible cabinet mounting >Visual and electrical indicators for on-site and remote reporting FlexNet ELPM-300 Specifications LPE and ELPM-300 — 300W for MDUs, Dark Spots and Business Parks Input: 85 to 170 or 132 to 264Vac selectable Frequency: 50 or 60Hz Output Voltage: 42 to 54Vdc Output Power: 300 Watts Dimensions H x W x D (in/mm): 6 x 10.1 x 3.25 / 152 x 256.5 x 82.6 Weight (lb/kg): 10 / 4.5 Number of Batteries: Four 12Vdc 50Ah (85GXL) Approx. Backup Time: 8 Hours @ 275W load LPE and FlexNet ELPM-300 Specifications 69 26 x 16.5 x 12 / 661 x 420 x 305 Enclosure Weight (lb/kg): 25 / 11.3 Material: Exterior powdercoated aluminum Number of Batteries: Four 12Vdc 17Ah Door and Lid Seal: Poron gasketing Approx. Backup Time: 4 Hours at 250W load PMR and GMR Series Specifications PMR-S1 Dimensions H x W x D (in/mm): 32.2 x 26 x 19.25 / 818 x 660 x 489 Weight (lb/kg): 40 / 18 GMR-S1 Dimensions H x W x D (in/mm): 31 x 27.5 x 20 / 787 x 699 x 508 Weight (lb/kg): 49 / 22 PMR-S2 Dimensions H x W x D (in/mm): 37 x 30 x 19.25 / 940 x 762 x 489 Weight (lb/kg): 47 / 21 GMR-S2 Dimensions H x W x D (in/mm): 38 x 31 x 20 / 965 x 787 x 508 Weight (lb/kg): 63 / 29 Number of Batteries: Four 12Vdc 50Ah (85GXL) Approx. Backup Time: 8 Hours at 275W load Enclosure Mounting and Door - PMR Series: Galvanized steel brackets for wood, and concrete pole mount and wall mount Enclosure Mounting and Door - GMR Series: Precast polymer concrete pad or PS-6/PS-6XL pedestal systems Fiber Strain Relief Tie Bar Optional: 19" mounting provides ability to strain relief fiber cable plugged into the front of communications equipment Splice Tray: Splice Tray Kit (12 count), includes Splice tray with elastomer splice block, felt tape, tie wraps, cover and recording label Fiber Management Panel: Provides fiber slack storage and secures a splice tray using a Velcro strap. Tie wrap slots on sides permit securing fiber cables to panel PMR and GMR Series — 300W for field deployment of TTx Optical Line Terminal (ONT) Fiber Power Systems Enclosure Dimensions H x W x D (in/mm): Wireless and Fiber Backhaul >5RU to 80RU enclosures available >High efficiency AC/DC powering options >Thermoelectric cooling, heat exchanger or air conditioning >Reduce installation time with optional power and optical integration >Turn-key installation and preventative maintenance services To support the growing demand for wireless carrier backhaul services, Alpha offers a comprehensive range of fully integrated backup powering solutions, including time-tested enclosures and power supplies. Designed to UL, NEMA or GR478 requirements, Alpha enclosures are an all-in-one solution to your backhaul and powering needs. The modular design allows you to claim valuable real estate now and expand your powering options in the future. >Flexible Backhaul Enclosure Alpha’s Flexible Backhaul Enclosure (FBE) is engineered to house optical fiber equipment to support high speed cellular data backhaul. Built with eleven rack mount spaces, the Alpha FBE is able to house fiber and powering gear including an Ethernet switch, power inverters, rectifiers, fiber splice tray, GMT and additional controls. An optional configuration enabling the addition of batteries, DC rectifiers and Service Utility Entrance is available. With Telecom-grade, 71 quarter-turn locks and key-operated Demark access, the FBE offers easy maintenance access >Wireless Transport Enclosure The Wireless Transport Enclosure (WTE) is ideal for Wireless Backhaul Business Services applications. It offers a self-contained total power solution for a wide range of applications including wireless outdoor base stations, wireless IP access and bulk power. With a compact 24” x 24” footprint, the WTE features a standard 19” rack mount system with 17RU (front/rear) of rack space and an internal Breaker Distribution Panel with GFCI and surge protection. >Te4(x) Alpha introduces its newest enclosure line, Te40, Te41 and Te45 Power Enclosures. Ranging from 84-inches tall (Te40, Te41) to 72-inches tall (Te45), all are third-party agency certified to meet GR-487 requirements (Zone 1 seismic and 70mph wind driven rain) and configurable to a range of different power and installation scenarios. Wireless and Fiber Backhaul and complete security. Flexible Backhaul Enclosure 2322 >Provides 15RU for 19" horizontal mounted equipment or 10RU for vertical mounted equipment >Front and side door access with removable lid >Durable welded aluminum construction >Wall, H-Frame, pole or ground mount options >Multiple thermal management options FBE2322-ENC FBE2322-ENC System Options Specifications Outer Dimensions H x W x D (in/mm): 29.6 x 27 x 24 / 751.84 x 685.8 x 609.6 Equipment Space: Front to back adjustable 19" 15RU horizontal or 23" 10RU vertical Access: Front hinged door, left and right lift off doors, removable lid Mounting: Wall, H-Frame, ground or precast mounting pad Thermal: Air conditioner with heater, heat exchanger, fan cooled with variable speed-control Emergency Ventilation System: Fan cooled with variable speed-control activated with high temp or HVAC fail alarm DC Power: 48Vdc Cordex HP 1.2kW rectifiers 70Amp 2 position or 100Amp 8 position Door Latch / Hinge Type: 1/4 turn padlockable / reversible 2 position lift off hinge AC Services Entrances: Generator: External L14-30P generator plug CSA/UL: 60950-22 ITE electrical enclosure Alarm: Alarm terminal block NEMA Rating: Type 3R 72 Wireless and Fiber Backhaul Enclosure Options FBE Modular Design CordexHP 1.2kW 48Vdc Modular Switched Mode Rectifier Multiple 48V configurations up to 125 Amps for various 48Vdc applications High Efficiency design for increased OpEx savings High Temperature rated fan-cooled design for harsh outdoor installations Cordex 4R/8D ADIO 1 Enclosure Lid 2 Auxiliary Equipment Enclosure 3 Base Equipment Enclosure 4 Battery Expansion Enclosure 5 10” Plinth / Mounting Options 6 Climate Control Options CXC Smart Peripheral Provides additional I/O expansion to existing CXC site controller Seamless expansion of four relay outputs and eight digital inputs Ideal for alternate device monitoring and control such as HVAC and generators 1 2 3 Fuses Panels Stand-Alone DC Distribution 19" and 23" rack mount models 12, 24 or 48V configurations Designed for flexible and custom DC distribution AlphaCell® 4 HPL-FT Batteries AGM runtimes up to 160 minutes in outdoor applications Absorbent Glass Mat (AGM) technology for efficient gas recombination HPL-FT features front terminal design with protective covers Specifically designed for mission-critical applications 5 Flexible Backhaul Enclosure 2319 >Modular enclosure system, allows for easy battery expansion >Demark access door >Front access for fan and filter maintenance >24 or 48V configurations FBE2319-ENC with Demark access door and fan cool option FBE2319-ENC Specifications Models: FBE2319-ENC FBE2319-ENC with Battery Enclosure Outer Dimensions H x W x D (in/mm): 27 x 23 x 22.3 / 686 x 584 x 565 41 x 23 x 22.3 / 1041 x 584 x 565 Weight (lb/kg): 57 / 26 82 / 37.5 Equipment Space: Front to back adjustable 19" 11RU Access: Front hinged door with demark access door Door Latch / Hinge Type: 1/4 Turn padlockable / reversible 2 position lift off hinge CSA/UL: 60950-22 ITE electrical enclosure NEMA Rating: Type 3R System Options Wall, H-Frame, Ground or Precast Mounting Pad Thermal: Heat exchanger, fan cooled with variable speed-control DC Power: 48Vdc Cordex HP 1.2kW rectifiers AC Services Entrances: 70Amp 2 position or 100Amp 8 position Generator: External L14-30P generator plug Alarm: Alarm terminal block 73 FBE2319-ENC with Heat Exchanger Door, Battery Expansion and Ground Mount Option Flexible Backhaul Enclosure 1417V >Provides 7RU for 19" vertically mounted equipment in smallest footprint possible >Front and side access to installed equipment >Wall or H-frame mount options >Aluminum welded construction with durable powdercoated exterior >Fan cooled with variable speed-control FBE1417V-ENC FBE1417V-ENC Specifications Outer Dimensions H x W x D (in/mm): 24.6 x 18 x 19.5 / 625 x 452 x 495 Weight (lb/kg): 35 / 15.9 Equipment Space: Vertical 19" 7RU Access: Front hinged door, left and right lift off doors Door Latch / Hinge Type: 1/4 Turn padlockable / reversible 2 position lift off hinge CSA/UL: NEMA Rating: 60950-22 ITE electrical enclosure Type 3R System Options Mounting: Wall or H-Frame Thermal: Fan cooled with variable speed-control 1RU Option Panel: Alarm terminal block, fiber management FBE1417V-ENC Wireless and Fiber Backhaul Mounting: Wireless Transport Enclosure >Equipment mounting area is 17RU >Equipment rails are front-to-back adjustable, suitable for mounting 19 inch rack mount equipment >Integrates Heat Exchanger and Thermoelectric Cooling System >Equipment area is cooled by an air-to-air heat exchanger with variable speed blower control >Internal L14-30P generator inlet plug with generator cord access through door >Optional precast mounting pad Wireless Transport Enclosure Wireless Transport Enclosure Specifications Wireless and Fiber Backhaul 74 System Specifications (As Shown) Outer Dimensions H x W x D (in/mm): 70 x 24 x 29 / 1778 x 610 x 737 Weight (lb/kg): 330 / 150 Equipment Space: Adjustable 19" 17RU plus 2 battery trays Access: Front hinged door and rear lift off door Door Latch / Hinge Type: 1/4 turn padlockable / reversible 4 position lift off hinge CSA/UL: 60950-22 ITE electrical enclosure NEMA Rating: Type 3R • Dual compartments - Upper compartment - heat exchanger - Lower compartment - thermoelectric cooling • Two battery trays (Consult factory for battery specifications) • Front to back adjustable 19" equipment mounting rails • Internal AC panel • Generator plug and transfer switch • Alarm terminal block • Ground bar System Options: Optional precast mounting pad Consult factory for custom system solutions Tempest Te45 Backhaul Enclosure 72" Single Compartment Power Enclosure >Designed for single or multiple enclosure applications >Durable welded aluminum construction >Variety of configurations possible with 39RU of space >Compact footprint and optional precast mounting pad >GR-487 compliant Tempest Te45 (open) Tempest Te45 Backhaul Enclosure Specifications System Specifications (As Shown) Dimensions H x W x D (in/mm): 72 x 30 x 30 / 1829 x 762 x 762 Weight (lb/kg): 600 / 273 Equipment Space: 23" 39RU Access: Removable rear panels and front hinged door Door Latch / Hinge Type: 3 point latch / 4 position lift off hinges Handle: Padlockable Battery Trays (Qty): Configuration dependent - 8RU per front terminal battery shelf CSA/UL: C22.2 No. 60950 NEMA Rating: Type 3R (CSAC22.2 No 94-M91) • 48Vdc Cordex 1.8kW rectifiers • AC panel c/w generator panel and ATS (Automatic Transfer Switch) • Air conditioner w/ heater • EVS (Emergency Ventilation System) • Alarm terminal block • Ground bar • Precast Mounting Pad available. See page 50 System Options: Consult factory for custom system solutions Tempest Te40 Backhaul Enclosure 84” Front Terminal Battery Enclosure >10 Strings at 24Vdc, 5 strings at 48Vdc >120Amp buss >Designed for single or multiple enclosure applications >Durable welded aluminum construction >Compact footprint and optional precast mounting pad Tempest Te40 Battery Tempest Te40 Backhaul Enclosure Specifications System Specifications (As Shown) Dimensions H x W x D (in/mm): 84 x 30 x 30 / 2134 x 762 x 762 Weight (lb/kg): 1300 / 590 Equipment Space: 23" 44RU • 5 battery shelves for GNB 155Ahr front terminal batteries • Air conditioner w/heater • Alarm terminal block • Ground bar • Precast Mounting Pad available. See page 50 Access: Removable rear panels and front hinged door System Options: Door Latch / Hinge Type: 3 point latch / 5 position lift off hinges Agency Standards: C22.2 No. 60954 NEMA Rating: Type 3R (CSAC22.2 No 94-M91) Consult factory for custom system solutions 75 Wireless and Fiber Backhaul Tempest Te41 Backhaul Enclosure 84" Dual Compartment Power Enclosure >Designed for single or multiple enclosure applications >Dual compartment system >Durable welded aluminum construction >Variety of configurations possible with 23RU of space >Compact footprint and optional precast mounting pad >Up to 39.6kW at 48Vdc or 34.1kW at 24Vdc >Multiple point cable access Tempest Te41 Power Tempest Te41 Backhual Enclosure Specifications System Specifications (As Shown) Dimensions H x W x D (in/mm): 84 x 30 x 30 / 2134 x 762 x 762 Weight (lb/kg): 1300 / 590 Equipment Space: 23” 19RU (upper), 26RU (Lower) Access: Removable rear panels and front hinged door Door Latch / Hinge Type: 2 point latch upper and lower compartments / 5 position lift off hinges Agency Standards: C22.2 No. 60953 • 48Vdc Cordex 3.6kW rectifiers (3.1kW Cordex system optional) • Qty 48 DC breaker positions • Qty 4 LVD disconnects for staged shutdown during power outage • AC panel c/w generator panel and ATS (Automated Transfer Switch) • Air conditioner w/ heater • Fan/filter ambient cooled upper compartment • Customer specific equipment layout • Alarm terminal block • Ground bar • Precast Mounting Pad available. See page 50 NEMA Rating: Type 3R (CSAC22.2 No 94-M91) System Options: Consult factory for custom system solutions Alpha Technologies Inc. 3767 Alpha Way Bellingham WA 98226 United States Tel: +1 360 647 2360 Fax: +1 360 671 4936 VISIT US AT WWW.ALPHA.COM Alpha Technologies Due to continuing product development, Alpha reserves the right to change specifications without notice. Copyright © 2011 Alpha Technologies Inc. All Rights Reserved. Alpha is a registered trademark of Alpha Technologies. 049-360-10-A002 (09/2012)