Spec No. 1604 | Rev. 06.09.16 | pg. 1/3 Heard Everywhere Since 1947 Model No's. SEQR-4, SEQR-4K 4-Step Rackmount Sequencers Low voltage, 4-step sequencers provide time-delayed activation and deactivation of equipment connected to remote power controls or accessory systems. The 1U chassis mounts in minimal rack space to sequentially activate equipment connected in the same rack or in remote locations. Select rocker or key activation switch. Features • Front mounted LEDs indicate status of connected equipment; front adjustable delay allows .5-10 seconds between steps. • Contacts for connecting remote switches • Each of the four control outputs includes switch contacts for connection to remote power control-activated equipment and auxiliary dry contacts for sequentially activating accessory systems such as projector screens, lighting, etc. • • • • • SEQR-4 Four rear-access barrier strip control outputs Alarm interface for use where required by local building code. SEQR-4K Steel chassis with rocker or key switch. 19"W x 1.75"H x 9"D. Black. UL Listed power supply with input 100-240VAC, output 24VDC, 500mA, 6 ft. cord and four plug adaptors — NEMA 1-15 for North America (factory installed) Schuko CEE 7/16 for central Europe, BS1362 for the U.K., AS3112 for Australia/New Zealand. Made in U.S.A. with domestic and imported components A&E Specifications Operation To Sequentially Activate Equipment: Connect each sequencer output (terminals labeled “Common” or “Switched Relay”) to a Remote Power Control (RPC Series) via a 2-conductor cable. Equipment to be switched on/off is plugged into the appropriate RPC. Each sequencer output can control up to 10 RPCs. To Sequentially Activate Accessory Systems or Indicator Devices: Each control output includes accessory contacts (Normally closed, Common, Normally open) with a rating of 5A for connection to peripheral devices. To Operate the Sequencer Remotely: Rear panel contacts can connect optional switch (up to 8 in parallel) using a 3 conductor wire. Lowell offers wall plate or rackmount switches with rocker or key activation. Order momentary switches separately. The device for sequentially activating equipment shall be Lowell rackmount Model No. ________, which shall feature front _______ (rocker, key) actuation switch _________, LEDs and accessible trim pot for 4step delay adjustment of sequence operation. The rear panel shall feature four barrier strip terminals for remote power control units and dry auxiliary contacts for accessory devices. Equipment to be controlled shall be connected to the sequencer using 2-conductor wire and Lowell Remote Power Control No. __________ (RPC Series, order separately). The rear panel shall include contacts for connecting an optional momentary style switch No. __________ (RPSW-M or RPSB-M Series, order separately) for remote operation of the sequence controller. The unit shall be equipped with an alarm interface for use where required by local building code. Lowell makes every effort to provide accurate information while reserving the right to change specifications and/or improve manufacturing methods without notification. ©2015 Lowell Manufacturing Company, 100 Integram Dr., Pacific MO 63069 | tel. 800.325.9660 | www.lowellmfg.com Spec No. 1604 | Rev. 06.09.16 | pg. 2/3 Heard Everywhere Since 1947 Front Panel Red LED flashes when system is cycling down and remains lit when system is off. Green LED flashes when system is cycling up and remains lit when system is on. Actuation switch (rocker or key depending on model). Activation in mid-cycle reverses direction. Green LEDs indicate sequence progress. Delay: recessed trim pot with screwdriver adjust. Rear Panel Auxiliary Dry Contacts* Normally Closed Common Normally Open Includes four plug adaptors. NEMA 1-15 is factory-installed. *Can be used to control other systems (lighting, etc.) or indicators. Contact rating = 5A max. Switch Contacts for Remote Power Controls** Common Switched Relay RPSW-MP RPSW-MKP **Up to 10 RPCs can be controlled by each sequencer step. (common connections from multiple remote RPCs controlled by different sequence steps can be consolidated into 1 conductor and connected to any common terminal at the sequencer.) Alarm Interface Alarm Interface: If required by local building code, facility usage, or Fire Marshal, the system switches can be overridden and the system controlled by contact closures provided on the fire alarm panel or other similarly installed device. A maintained contact between the “Com” terminal and any of the terminals shown will provide the following functions: LOCK OFF: A maintained contact between the “Com” terminal and the “Lock Off” terminal will turn the system off and keep it off regardless of other switch activations. If the system is already off it will remain off. Optional Remote Switches Optional Remote Switch Connection: Up to 8 momentary switches can be connected in parallel. Maximum wire distances for momentary switches: 24 ga. = 20,000 ft. 22 ga. = 31,200 ft. 18 ga. = 76,800 ft. LOCK ON: A maintained contact between the “Com” terminal and the “Lock On” terminal will turn the system on and keep it on regardless of other switch activations. If the system is already on it will remain on. SWITCH LOCK: A maintained contact between the “Com” terminal and the “Switch Lock” terminal will lock the system in its current state (on or off) regardless of any other switch activations. CAUTION: Do not allow alarm system to make more than one of the above described contacts at the same time. Controller board damage could result. Lowell makes every effort to provide accurate information while reserving the right to change specifications and/or improve manufacturing methods without notification. ©2015 Lowell Manufacturing Company, 100 Integram Dr., Pacific MO 63069 | tel. 800.325.9660 | www.lowellmfg.com Spec No. 1604 | Rev. 06.09.16 | pg. 3/3 Heard Everywhere Since 1947 Typical Application Sequencer Model Numbers Model No. SEQR-4 SEQR-4K Description 4-step rackmount sequencer 4-step rackmount sequencer Note: Sequencers formerly known as No's. SCS-4R and SCS-4RK Activation Switch Rocker Key Delay (front panel trip pot) 0.5-10 sec. between steps 0.5-10 sec. between steps Power Requirement 100-240 VAC 500mA max 100-240 VAC 500mA max System Accessories (order separately) Remote Power Controls (stand-alone units) RPC-15 Power Control — 15A, 1 duplex outlet, 7.5 x 3.25 x 1.75, 6 ft cord RPC-20-CD Power Control — 20A, 1 duplex outlet, 7.5 x 3.25 x 2.75, 6 ft cord RPC-20-SCD Power Control — 20A, 1 duplex outlet, 7.5 x 3.25 x 2.75, surge suppression, 6 ft cord RPC-30-SHW Power Control — 30A, 1 twistlock outlet, 7.5 x 3.25 x 2.75, 6 ft conduit Power Strips with Remote Power Control ACS-1510-RPC 30" power strip with 10 (15A) outlets, detachable cord and remote power control ACS-2010-RPC-HW 30" power strip with 10 (20A) outlets, flexible conduit (hardwired), and remote power control Surge Suppressors with Remote Power Control ACSP-1502-RPC Compact Surge Suppressor with remote power control, 2 (15A) outlets, cord ACSP-2002-RPC Compact Surge Suppressor with remote power control, 2 (20A) outlets, cord Remote Switches with MOMENTARY Closure (multiple switch use). Key versions also available. RPSW-MP Momentary Switch (1 gang wall plate) — SPST rocker switch with 1 LED RPSW2-MP Momentary Switch (1 gang wall plate) — SPST rocker switch with 2 LEDs RPSB-MR Momentary Switch (1U rack panel) — SPST rocker switch with 1 LED RPSB2-MR Momentary Switch (1U rack panel) — SPST rocker switch with 2 LEDs] Visit our website for additional system accessories.(www.lowellmfg.com) Lowell makes every effort to provide accurate information while reserving the right to change specifications and/or improve manufacturing methods without notification. ©2015 Lowell Manufacturing Company, 100 Integram Dr., Pacific MO 63069 | tel. 800.325.9660 | www.lowellmfg.com