1746 - Lowell

advertisement
Spec No. 1746
[REV. 04.28.16] Page 1/2
Model No’s. ACR-1509, ACR-1509-S
Rackmount
Panels
(15A) AC power outlets, optional surge protection
Features:
•
ETL Listed in the US and Canada (UL Standard 60065)
•
Made in the USA with global components
•
19”W x 9”D x 1U steel chassis
•
Lighted rocker activation switch on front
•
9-ft. attached cord with NEMA 5-15P plug
•
Power Rating: 120VAC, 60Hz, 15A (NEC Art.210.21 [B] [2] rating
12A) 15A circuit breaker
ACR-1509
Model Specific Features:
Model No. ACR-1509:
•
­Rear outlets: 5 switched, 3 unswitched
•
Front outlet: 1 unswitched (always on)
Model No. ACR-1509-S:
•
Rear outlets: 3 switched, 5 unswitched
•
Front outlet: 1 unswitched
•
Basic Surge Protection
•
­LED status indicator on front shows protection is active
•
Maximum Surge Current: 30,000A
•
VPR (UL1449-3): 400V
•
Endurance: 100 WCS* (unlimited low level surges)
•
Response Time: 1 nanosecond
•
EMI/RFI Noise Reduction: 20dB@100kHz
•
Protection Mode: Line to neutral only. No ground contamination.
A & E Specifications:
The AC rackmount power panel shall be Lowell Model ACR-1509. It shall be ETL
Listed and have a power rating of 120VAC, 60Hz, 15A with nine outlets. Front
activation shall be via a lighted rocker switch. Termination shall be a 9-ft. cord
with NEMA 5-15P plug. The steel chassis shall be 1U x 19”W x 9”D and have a
black powder epoxy finish.
[Lowell Model ACR-1509-S: Unit shall also include surge protection.]
* Surge Protection Endurance WCS (Worst Case Situation): Defined as power quality disruptions likely
to cause facility infrastructure damage such as direct lightening strike, transmission line cross-connection or collapse (from severe storm, ice damage, etc.) sub-station transformer explosion, etc.
Industry standards for residential and commercial service entrance equipment limit surges entering a
facility from external sources to maximum of 6kV and 10kA.
Lowell makes every effort to provide accurate information while reserving the right to change specifications and/or improve manufacturing methods without notification.
©2016 Lowell Manufacturing Company, 100 Integram Dr., Pacific MO 63069 | 800.325.9660 | www.lowellmfg.com
Spec No. 1746
Rocker Switch
Activation
[REV. 04.28.16] Page 2/2
Circuit Breaker
ACR-1509
FRONT VIEW
REAR VIEW
Includes 9-ft. attached cord
with NEMA 5-15P plug
Rocker Switch
Activation
Circuit Breaker
ACR-1509-S
FRONT VIEW
Green LED - Protection active when lit
REAR VIEW
Includes 9-ft. attached cord
with NEMA 5-15P plug
Model No. Summary
Model No. ACR-1509
ACR-1509-S
Description
Rackmount power panel
Rackmount power panel
Front Outlets *
1-unswitched
1-unswitched
Rear Outlets *
5-switched, 3-unswitched
3-switched, 5-unswitched
Surge Protection
---
basic
* Unswitched outlets are always on.