CVEN 4555 Reinforced Concrete Design George.Hearn@coloado.edu 1 Aug 23 – Loads. Load Combinations. ACI 318-14 Chapter 2 Notation and Terminology Chapter 5 Loads Using ACI318-14, define these terms and notations Mn nominal flexural strength at section, in.-lb Mu factored moment at section, in.-lb Pn nominal axial compressive strength of member, lb Pu factored axial force; to be taken as positive for compression and negative for tension, lb U strength of a member or cross section required to resist factored loads or related internal moments and forces in such combinations as stipulated in this Code Vn nominal shear strength, lb Vu factored shear force at section, lb design load combination - combination of factored loads and forces. load - forces or other actions that result from the weight of all building materials, occupants, and their possessions, environmental effects, differential movement, and restrained dimensional changes; permanent loads are those loads in which variations over time are rare or of small magnitude; all other loads are variable loads. load, dead - (a) the weights of the members, supported structure, and permanent attachments or accessories that are likely to be present on a structure in service; or (b) loads meeting specific criteria found in the general building code; without load factors. load, factored - load, multiplied by appropriate load factors. strength, design - nominal strength multiplied by a strength reduction factor . strength, nominal - strength of a member or cross section calculated in accordance with provisions and assumptions of the strength design method of this Code before application of any strength reduction factors. strength, - strength of a member or cross section required to resist factored loads or related CVEN 4555 Reinforced Concrete Design required George.Hearn@coloado.edu 2 internal moments and forces in such combinations as stipulated in this Code. CVEN 4555 Reinforced Concrete Design George.Hearn@coloado.edu 3 ACI 318-14 Chapter 5 Loads 5.3.1 Required strength U shall be at least equal to the effects of factored loads in Table 5.3.1, with exceptions and additions in 5.3.3 through 5.3.12. Table 5.3.1—Load combinations Load combination Equation Primary load U = 1.4D (5.3.1a) D U = 1.2D + 1.6L + 0.5(Lr or S or R) (5.3.1b) L U = 1.2D + 1.6(Lr or S or R) + (1.0L or 0.5W) (5.3.1c) Lr or S or R U = 1.2D + 1.0W + 1.0L + 0.5(Lr or S or R) (5.3.1d) W U = 1.2D + 1.0E + 1.0L + 0.2S (5.3.1e) E U = 0.9D + 1.0W (5.3.1f) W U = 0.9D + 1.0E (5.3.1g) E List of load terms D = effect of service dead load E = effect of horizontal and vertical earthquake-induced forces L = effect of service live load Lr = effect of service roof live load R = cumulative load effect of service rain load S = effect of service snow load U = strength of a member or cross section required to resist factored loads or related internal moments and forces in such combinations as stipulated in this Code W = effect of wind load CVEN 4555 Reinforced Concrete Design George.Hearn@coloado.edu 4 Exercise – Loads, Load Combinations Given loads acting on a reinforced concrete deck D psf L psf Lr psf S psf W psf 50 40 20 22 -8 Run load combinations, find greatest U in psf on deck Solution D L Lr S W 50 40 20 22 -8 psf psf psf psf psf a 1.4 0 b 1.2 1.6 0.5 0.5 Load factors D L Lr S W c 1.2 0.5 1.6 1.6 0.5 d 1.2 0.5 0.5 0.5 1 e 1.2 0.5 c 60 20 32 35.2 -4 d 60 20 10 11 -8 e 60 20 0 4.4 0 f 0.9 g 0.9 0.2 1 Factored Loads D psf L psf Lr psf S psf W psf a 70 0 0 0 0 b 60 64 10 11 0 Combos, psf 70.0 135 115 f 45 0 0 0 -8 g 45 0 0 0 0 83.0 84.4 37.0 45.0 5.3.2 The effect of one or more loads not acting simultaneously shall be investigated. Combos, psf 70.0 135 115 91.0 84.4 45.0 45.0 U = 135psf CVEN 4555 Reinforced Concrete Design George.Hearn@coloado.edu 5 Deck is supported by reinforced concrete joists and reinforced concrete columns CVEN 4555 Reinforced Concrete Design George.Hearn@coloado.edu 6 Joist spacing is 3 ft. Get U. Factored Loads D plf L plf Lr plf S plf W plf a b c d e f g 210 180 180 180 180 135 135 0 192 60 60 60 0 0 0 30 96 30 0 0 0 0 33 106 33 13.2 0 0 0 0 -12 -24 0 -24 0 Combos, plf 210 405 346 249 253 111 135 5.3.2 The effect of one or more loads not acting simultaneously shall be investigated. Combos, psf 210 405 346 273 253 135 135 U = 405plf CVEN 4555 Reinforced Concrete Design George.Hearn@coloado.edu 7 Column spacing is 14’ x 16’ Trib area is 224 SF. Get U Factored Loads D lb L lb Lr lb S lb W lb a 15680 0 0 0 0 b 13440 14336 2240 2464 0 c 13440 4480 7168 7884.8 -896 Combos, lb 15680 30240 25805 15700 30200 25800 d 13440 4480 2240 2464 -1792 e 13440 4480 0 986 0 f 10080 0 0 0 -1792 18592 18906 8288 18600 18900 8290 g 10080 0 0 0 0 10080 10100 5.3.2 The effect of one or more loads not acting simultaneously shall be investigated. Combos, lb 15700 30200 25800 20400 18900 10100 10100 U = 30,200 lb