www.reznor.eu PREEVA packaged heat pump air handling unit • COP 4,2 • EER 4 • R410A • free cooling • no emissions • customizable design • short delivery times • plug & play PREEVA + PUHY air handling UNITS with heat pump FOR HEATING, VENTILATION AND COOLING Introduction Features and benefits In times of progressively stricter emissions and energy norms, where the impact on available resources must be minimized, the desire for comfort yet remains. • Heat pump for both heating and cooling • Inverter compressors and electronic expansion valve: high efficiency Despite the fact that in our European climate there are generally more heating days than there are cooling days, more end users require cooling in addition to heating. To meet these needs for maximum year round comfort against a minimal use of energy, Reznor and Mitsubishi Electric have co-developed a new concept. The PREEVA + PUHY has been designed as a standalone installation combining the proven versatility of an air handling unit with the highest efficiencies of a heat pump, without an additional heating energy source. This installation provides: • • • • Since no combustion takes place, no emissions are produced and no flue system is required R410A as a non-ozone depleting refrigerant Reduced vibrations and silent operation • Maximum installation flexibility • Plug & play: pre-programmed control, installation fully tested before dispatch • cooling and heating by heat pump • free cooling and free heating by fresh air • ventilation • • Excellent COP and EER, for a lower energy consumption than comparable units Support in dimensioning and calculations Short delivery times Quality and Standards • CE • ISO 9001 Model Range PREEVA + PUHY units are available standard as weatherproof outdoor models (RD), suitable for rooftop or low level installation, or optionally as indoor models (SD). The PREEVA + PUHY range has 4 models with heating outputs between 25 and 63 kW, and cooling outputs between 22 and 56 kW. Options • Panel filters and bag filters, class G4 to F7 • Duct flange bottom, rear, top or side • Heat recovery section in which fresh air is pre-heated by exhaust air • In case additional heating capacity is required, it remains possible to choose an additional gas fired heating section. For the gas fired heating specifications, please see the separate PREEVA bro- Controls Mitsubishi Electric and Reznor offer user friendly controls that facilitate and optimize start-up and operation. • Factories • commercial premises • warehouses chure. Installation • halls • sports & leisure • restaurants Depending on available space and on building regulations, the units may have to be installed outdoors at a distance from one another, or the PREEVA may have to be installed indoors. These configurations are also possible. The PUHY can be placed at a distance equalling refrigerant piping length of up to 1000 m, with a height difference of up to 50 m. Delivered pre-programmed • Day- and week settings • Overtime mode • Protection against undesired modification • Large, backlit display • Multi-language menus • Compatible with various network protocols • Easy to use menus Mitsubishi Electric PAR-31MAA For your convenience, Reznor has developed a base frame accomodating both the PREEVA and the PUHY on a rooftop or at ground level. Applications • The PREEVA + PUHY is controlled by Mitsubishi Electric's PAR-31MAA. In case the PREEVA + PUHY has the optional gas fired heating section, it is controlled by the Carel pCO5. Carel pCO5 Technological effiency PREEVA The PUHY units are connected to a DX-coil within the PREEVA. About Mitsubishi Electric Mitsubishi Electric is a Japanese industrial group that is a worldwide leader in manufacturing and sales of market leading electric and electronic equipment. Reznor has selected Mitsubishi Electric's PUHY range to offer end users a renewable alternative to gas fired heating and to water and steam coil heating. Mitsubishi Electric is active on the HVAC market with a competitive range of high efficiency air conditioning products for split applications, such as the PUHY heat pump, which is designed to connect to indoor terminal units, as well as to the DX coil of air handling units such as the PREEVA. In addition, the application range of Reznor's succesful PREEVA range can now be extended even further, for example where gas fired heating is not suited, or where an application with both heating and cooling is required. Day 56dB(A) Night 49dB(A) Most of the time, a heat pump does not have to operate at maximum capacity. This is why the PUHY has an electronic expansion valve to control the flow of the coolant, while the variable frequency drive allows the compressor to operate on partial load. This saves energy and minimizes the number of starts and stops, hereby increasing longevity. This combination provides a continuous, linear output that allows a very precise control of temperature and, consequently, improved indoor comfort. PUHY PAC-AH M Databus Schematic representation PREEVA + PUHY air handling UNITS with heat pump FOR HEATING, VENTILATION AND COOLING Optimized silenced operation, only 49 dB(A) in night mode Mixing cabinet with filters class G4 to F7, and aerodynamic counter-rotating air inlet dampers for precise control of the Fresh air/Return air ratio Blower cabinet with centrifugal motor driven fan or plug fan for external static pressures up to 400 Pa Various duct connections are available: rear duct spigot, downturn cabinet, (as illustrated) or a cabinet with spigot at the top or at the sides Integrated controls Insulated section with DX coil, connected to the PUHY heat pump Weatherproof body consisting of insulated prepaint panels with integrated access panels for easy service Heat exchanger with dirt repellant design and corrosion protection Inverter controlled scroll compressors As a standard, Reznor will supply the PREEVA + PUHY packaged on a single base frame for outdoors installation. However, to provide the installer and user maximum installation flexibility, alternative configurations can equally be specified, with the PUHY placed outdoors and the PREEVA either indoors, or outdoors at a distance from the PUHY. When the PREEVA + PUHY is ordered as a packaged unit on the single base frame, it is delivered with all piping connected and the refrigerant pre-filled before dispatch, thereby reducing installation time and costs. PREEVA + PUHY air handling UNITS with heat pump FOR HEATING, VENTILATION AND COOLING A G C H I J K L TECHNICAL DATA REZNOR PREEVA + mitsubishi electric PUHY O B PREEVA RD + PUHY packaged on base frame F D E PUHY model M N S P kW Cooling output kW P200 P250 P400 P500 25,0 31,5 50,0 63,0 28,0 45,0 56,0 4,29 3,90 4,19 EER cooling 1, 2 3,98 3,78 3,43 3,64 m3/h m3/h m3/h 1700 3500 3500 2500 5100 5100 3900 8000 5750 5300 10600 9800 dB(A) 56 58 61 61 mm 920 760 1710 920 760 1710 1220 760 1710 1870 760 1710 Weight PUHY kg 190 200 245 400 Weight PREEVA5 kg 212 246 289 360 Dimensions PUHY Width Depth Height 4 Pa 400 Coolant dimensions REZNOR PREEVA + mitsubishi electric PUHY PUHY model RD73 22,4 Maximum external static pressure RDH25 RD55 4,28 Sound level PUHY 3 PREEVA RDH + PUHY on single base frame RD35 COP heating 1, 2 Airflow Minimum @ 15oC Maximum @ 15oC Maximum @nom. cooling capacity Q R Heat output RD25 RDH35 RDH55 RDH73 3 P200 P250 P400 P500 A 1910 2164 2210 3153 B 840 1094 840 1268 C 920 920 1220 1870 D 1830 1830 1830 1830 E 853 853 1088 1088 F 120 120 120 120 G1 4325 4325 5165 5165 G2 2036 2036 4278 4278 H 600 600 835 835 I1 1454 1454 1722 1722 I2 835 835 835 835 J 600 600 600 600 K 1020 1020 1192 1192 L 651 651 816 816 M1 3674 3674 4114 4114 N 2010 2264 2310 3388 O 160 160 160 160 P 583 837 583 710 Q 602 702 602 1002 R 451 451 686 686 S 302 302 502 502 1 Dimensions given for a PREEVA + PUHY with centrifugal fan and with the optional gas fired heating section, as illustrated above 2 Dimensions given for a PREEVA + PUHY with centrifugal fan but without the optional gas fired heating section 3 The RDH25-P200, RDH35-P250 and RDH55-P400 can be delivered packaged: together on a single base frame, with all connections made, pre-filled with coolant, programmed controls etc. The packaged RDH73-P500, however, is too wide for standard transport and its installation must be completed on site. R410A Coolant quantity kg 6,5 8 11,5 16 Coolant liquid connection Ø 3/8 3/8 1/2 5/8 Coolant gas connection Ø 3/4 7/8 1 1/8 1 1/8 Maximum piping length m 1000 Maximum piping height m 50 Electrical supply V 380-415V 3N - 50Hz Power consumption cooling kW 5,62 7,40 13,11 15,38 Power consumption heating kW 5,84 7,34 12,82 15,03 Nominal current cooling A 9,4 12,4 22,1 25,9 Nominal current heating A 9,8 12,3 21,6 25,3 Fuse rating 6 A 25 32 63 64 1 Conditions: Cooling : indoor temperature 27°CDB/19°CNB , outdoor temperatuur 35°CDB 2 Conditions: Heating: indoor temperature 20°CDB , outdoor temperature 7°CDB/6°CNB 3 Sound levels are measured at 1 m of the PUHY unit and 1 m above the unit 4 height is for PUHY unit only, optional base frame not included 5 weights given for PREEVA with centrifugal fan and with optional gas fired heat exchanger 6 A separate fuse must be used for every module For further information about the PREEVA and the gas fired heating section, please see the separate PREEVA brochure PREEVA+PUHY 2014-10 EN J&M Sabbestraat 130/A000 B-8930 Menen Belgium Tel. +32(0) 56 52 95 11 Fax. +32(0) 56 52 95 33 reznor.europe@nordyne.com www.reznor.eu Company Standards and Services: All Reznor products are tested and approved to CE standards. Reznor Europe nv is assessed to ISO 9001 Quality Assurance. Reznor offers a service to its customers; including budget schemes, on site technical support and a comprehensive after-sales package. Reznor reserves the right to change specifications without prior notice.