------ TOTAL SITE AREA: ----- SF (---- ACRES) DENSITY: -------- GAUGE GALVANIZED GYPSUM BOARD GLASS GROUND GRADE GYPSUM H.B. H.C. HDCP. HDW. H.M. HORIZ. HR. HT. HTG HOSE BIBB HOLLOW CORE HANDICAP HARDWARE HOLLOW METAL HORIZONTAL HOUR HEIGHT HEATING GRID LINE AND BUBBLE I.D. INCL. INSUL. INT. (DIM) INSIDE DIAMETER INCLUDE INSULATION INTERIOR WALL TAG JAN. JT. JANITOR JOINT KIT. K.O. KITCHEN KNOCKOUT --- SHEET CALLOUT IS ON SECTION REFERENCE ROOM NAME ROOM TAG AREA --- WINDOW TAG PANIC HARDWARE HO PH # DOOR TAG HOLD OPEN LEVEL NAME LEVEL / ELEVATION REFERENCE ### REVISION CLOUD REVISION TAG # -- ---- -- -- EXTERIOR --- -- DOUBLE DEMOLISH DETAIL DRINKING FOUNTAIN DIAGONAL DIAMETER DIMENSION DISPENSER DIVISION DOWN DOOR DOWNSPOUT DRAWING GA. GALV. G.B. GL. GND. GRD. GYP. CALLOUT OR SECTION NUMBER # DBL. DEMO. DET. D.F. DIAG. DIAM. DIM. DISP. DIV. DN. DR. DS. DWG. FACE BRICK FLOOR DRAIN FOUNDATION FIRE EXTINGUISHER FINISH FLOOR FLASHING FLUORESCENT FACE OF CONCRETE FACE OF FINISH FACE OF STUDS FIREPROOF FOOT OR FEET FOOTING FURRING FUTURE FIRE RATED SHEET DETAIL IS ON BUILDING SECTION CABINET CONCRETE BRICK CEMENT CERAMIC CUBIC FOOT CORNER GUARD CEILING CAST IRON CLEAR CONC. MASONRY UNIT COUNTER CASED OPENING COLUMN CONCRETE CONNECTION CONSTRUCTION CONTINUOUS CONTRACTOR CARPET COUNTERSINK CERAMIC TILE CUBIC YARD F.B. F.D. FOUND F.E. FIN. FL. FLASH. FLUOR. F.O.C. F.O.F. F.O.S. FP. FT. FTG. FURR. FUT. FR. --- WALL SECTION CAB. C.B. CEM. CER. C.F. C.G. CLG. C.I. CLR. C.M.U. CNTR. C.O. COL. CONC. CONN. CONSTR. CONT. CONTR. CPT. CSK. C.T. C.Y. EAST EACH EXPANSION JOINT ELEVATION ELECTRICAL ELEVATION/ELEVATOR ENCLOSED EQUAL EQUIPMENT ELECTRIC WATER COOLER EXISTING EXPANSION EXTERIOR DETAIL OR SECTION NUMBER - BOARD BITUMINOUS BUILDING BLOCK. BLOCKING BEAM BOTTOM BASEMENT BUILT-UP ROOFING BULLNOSE E. EA. E.J. EL. ELEC. ELEV. ENCL. EQ EQUIP. E.W.C. EXIST. EXP. EXT. REFERENCE SYMBOLS - BD. BITUM. BLDG. BLK. BLKG BM. BOT. BSMT BUR. BN. ELEVATION REFERENCE INTERIOR LAB. LAM. LAV. LKR. LT. LVR. L.W. LABORATORY LAMINATE LAVATORY LOCKER LIGHT LOUVER LIGHTWEIGHT MAS. MAX. M.C. MECH. MEMB. MET. MFR. MH. MIN. MIR. MISC. M.O. MOD. MT. MTD. MATL. MUL. MASONRY MAXIMUM MEDICINE CABINET MECHANICAL MEMBRANE METAL MANUFACTURER MANHOLE MINIMUM MIRROR MISCELLANEOUS MASONRY OPENING MODULAR MOUNT MOUNTED MATERIAL MULLION 2. CONTRACTOR SHALL USE EXTREME CARE AND CAUTION DURING THE CONSTRUCTION SO AS NOT TO DAMAGE ANY ON OR OFF-SITE EXISTING FACILITIES. ANY DAMAGE DONE BY THE CONTRACTOR TO EXISTING FACILITIES SHALL BE REPAIRED TO THE SATISFACTION OF AND AT NO EXPENSE TO THE OWNER. N. N.I.C. NO. OR # NOM. N.T.S. NORTH NOT IN CONTRACT NUMBER NOMINAL NOT TO SCALE 4. MANUFACTURERS OF MATERIALS OTHER THAN THOSE SPECIFIED ON THESE PLANS SHALL MEET THE SPECIFIC REQUIREMENTS OF GOVERNING AGENCIES HAVING JURISDICTION OVER THIS PROJECT. CONTRACTOR SHALL BE RESPONSIBLE FOR APPROVALS OF SUBSTITUTED MATERIALS AND CHANGES TO THE PROJECT AS REQUESTED BY THE GOVERNING AGENCIES, WITH NO ADDITIONAL COST TO THE OWNER. O.A. O.C. O.D. OFF. OH. OPNG. OPP. OVERALL ON CENTER (DIM) OUTSIDE DIAMETER OFFICE OVERHEAD OPENING OPPOSITE PL. P.LAN. PLAS. PLYWD. PLUMB. PNT. PR. PRCST. PREFAB. PT. PTD. P.T.DISP PTN. PVC. PLATE PLASTIC LAMINATE PLASTER PLYWOOD PLUMBING PAINT PAIR PRE-CAST PREFABRICATED POINT PAINTED PAPER TOWEL DISPENSER PARTITION POLYVINYL CHLORIDE Q.T. QUARRY TILE R. R.A. RAD. R.D. REF. REFR. REG. REINF. REM. REQ'D. RESIL. REV. RM. R.O. RWD. RISER RETURN AIR RADIUS ROOF DRAIN REFERENCE REFRIGERATOR REGISTER REINFORCE/REINFORCING REMOVE REQUIRED RESILIENT REVERSE ROOM ROUGH OPENING REDWOOD S. S.C. SCHED. S.D. SECT. SH. SHT. SHWR. SIM. S.N.D. S.P. SPEC. SQ. S.S. STA. STD. STL. STOR. STRUCT. SUSP. SYM. SYN. SOUTH SOLID CORE SCHEDULE STORM DRAIN SECTION SHELF SHEET SHOWER SIMILAR SANITARY NAPKIN DISPENSER SOUNDPROOF SPECIFICATION SQUARE STAINLESS STEEL STATION STANDARD STEEL STORAGE STRUCTURAL SUSPENDED SYMMETRICAL SYNTHETIC T.B. T.O.C. TEL. TERR. T. & G. THK. T.O.M. T.O.W. T.P.D. TR. TV. TYP. TOWEL BAR TOP OF CURB TELEPHONE TERRAZZO TONGUE AND GROOVE THICK TOP OF MASONRY TOP OF WALL TOILET PAPER DISP. TREAD TELEVISION UNFINISHED UNF. U.O.N. UR. UNFINISHED UNLESS OTHERWISE NOTED URINAL V.C.T. V.B. VER. VERT. VEST. V.T. VINYL COMPOSITION TILE VINYL BASE VERIFY VERTICAL VESTIBULE VINYL TILE W. W/ W.C. WD. W/O. WP. WSCT. WT. W.W.F. WEST WITH WATER CLOSET WOOD WITHOUT WATERPROOF WAINSCOT WEIGHT WELDED WIRE FABRIC B. GENERAL: 1. CONTRACTOR AGREES THAT HE SHALL ASSUME THE SOLE AND COMPLETE RESPONSIBILITY FOR SITE CONDITIONS DURING THE COURSE OF THE CONSTRUCTION OF THE PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS; & THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY, AND HOLD THE OWNER AND ARCHITECT HARMLESS FROM ANY AND ALL LIABILITY, REAL, OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OR THE WORK ON THIS PROJECT. 3. THE CONTRACTOR SHALL NOTE THAT THERE SHALL BE NO SUBSITUTIONS AFTER BIDDING AND NEGOTIATIONS, FOR ANY MATERIAL WHERE SPECIFIC MANUFACTURERS ARE SPECIFIED. WHERE APPROVED EQUAL IS USED IT SHALL BE UNDERSTOOD THAT THE SUBSITUTION SHALL BE JUDGMENT AND APPROVAL OF THE ARCHITECT. 5. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT THE JOB SITE BEFORE COMMENCING WORK AND SHALL IMMEDIATELY REPORT ANY DISCREPANCIES TO THE ARCHITECT. 6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DISTRIBUTE ADEQUATE COPIES OF ALL DRAWINGS TO ALL TRADES FALLING UNDER THEIR RESPONSIBILITY AT ALL TIMES DURING THE PROGRESS OF THE JOB (I.E. REVISIONS). 7. THE CONTRACTOR SHALL AT ALL TIMES, KEEP PREMISES FREE FROM ACCUMULATION OF DEBRIS. AT THE COMPLETION OF THE WORK, HE SHALL CLEAN ALL GLASS SURFACES AND LEAVE THE WORK "BROOM CLEAN". 8. THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIAL EQUIPMENT, AND OTHER ITEMS NECESSARY FOR THE COMPLETION OF ALL WORK SHOWN, CALLED FOR, OR REASONABLY IMPLIED BY THE CONTRACT DOCUMENTS EXCEPT WHERE SPECIFICALLY NOTED OTHERWISE. 9. WHERE WORK OR EQUIPMENT IS INDICATED "BY OTHERS" SUCH WORK AND/OR EQUIPMENT SHALL BE PART OF THE CONTRACT AND PROVIDED BY GENERAL CONTRACTOR AND/OR OTHER TRADES. THE CONTRACTOR SHALL COORDINATE AND COOPERATE TO EFFECT SUCH INSTALLATION. 10. CONTRACTOR SHALL PROVIDE TEMPORARY CONSTRUCTION FENCES/BARRIERS AROUND ALL CONSTRUCTION AREAS. 11. CONTRACTOR SHALL SUPPLY ONE (1) SET OF AS-BUILT CONSTRUCTION DOCUMENTS WHICH SHALL INCLUDE PLANS AND SPECIFICATIONS BEARING RED MARKS/NOTES INDICATING CHANGES AND MODIFICATIONS. 12. UPON COMPLETION OF THE JOB, THE CONTRACTOR SHALL SUBMIT CERTIFICATES OF INSPECTION OF SATISFACTORY COMPLETION. S1.0 S1.0-1 S1.0-2 S1.1 S1.2 DEMOLITION TITLE SHEET SITE PLAN ADA NOTES ADA + CALGREEN NOTES PLANS & INT. ELEVATIONS - RESTROOM BUILDING ROOF & CEILING PLANS - RESTROOM BUILDING PLANS & INT. ELEVATIONS - EDUCATION BUILDING PLANS & INT. ELEVATIONS - MULTI-USE BUILDING EXTERIOR ELEVATIONS - RESTROOM BUILDING EXTERIOR ELEVATIONS - EDUCATION BUILDING DOOR SCHEDULE & DOOR TYPES WINDOW SCHEDULE & TYPES DETAILS DETAILS Structural Notes STRUCTURAL NOTES STRUCTURAL OBSERVATION NOTES New Structures New Restrooms 5. WATER HEATERS MUST BE STRAPPED TO A WALL (SEC. 507.3, UPC) F. ADDITIONAL NOTES 1. NOT USED 2. EVERY SPACE INTENDED FOR HUMAN OCCUPANCY SHALL BE PROVIDED WITH NATURAL LIGHT BY MEANS OF EXTERIOR GLAZED OPENINGS IN ACCORDANCE WITH SECTION 1205.2 OR SHALL BE PROVIDED WITH ARTIFICIAL LIGHT THAT IS ADEQUATE TO PROVIDE AN AVERAGE ILLUMINATION OF 10 FOOT-CANDLES OVER THE AREA OF THE ROOM AT A HEIGHT OF 30 INCHES ABOVE THE FLOOR LEVEL. (1205.1 AND 1205.3) c. AT ALL INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND HORIZONTAL SPACES SUCH AS OCCUR AT SOFFITS, DROP CEILINGS, AND COVE CEILINGS. d. IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP AND BOTTOM OF THE RUN AND BETWEEN STUDS ALONG AND INLINE WITH THE RUN OF STAIRS IF THE WALL UNDER THE STAIRS IS UNFINISHED. e. IN OPENINGS AROUNDS VENTS, PIPES, DUCTS, CHIMNEYS, FIREPLACES, AND SIMILAR OPENINGS WHICH AFFORD A PASSAGE FOR FIRE AT CEILING AND FLOOR LEVELS WITH NON-COMBUSTIBLE MATERIALS. 7. DRAFT-STOPS MUST BE PROVIDED IN THE FOLLOWING LOCATIONS: 3. ELECTRICAL RECEPTACLE OUTLETS ON BRANCH CIRCUITS OF 30 AMPERES OR LESS AND COMMUNICATION SYSTEM RECEPTACLES SHALL BE LOCATED NO MORE THAN 48 INCHES MEASURED FROM THE TOP OF THE RECEPTACLE OUTLET BOX OR RECEPTACLE HOUSING NOR LESS THAN 15 INCHES MEASURED FROM THE BOTTOM OF THE RECEPTACLE OUTLET BOX OR RECEPTACLE HOUSING TO THE LEVEL OF THE FINISHED FLOOR OR WORKING PLATFORM. IF THE REACH IS OVER AN OBSTRUCTION BETWEEN 20 AND 25 INCHES IN DEPTH, THE MAX. HEIGHT MEASURED AT THE BOX IS REDUCED TO 44 INCHES FOR FORWARD APPROACH, OR 46 INCHES FOR SIDE APPROACH, PROVIDED THE OBSTRUCTION IS NO MORE THAN 24 INCHES IN DEPTH. OBSTRUCTIONS SHALL NOT EXTEND MORE THAN 25 INCHES FROM THE WALL BENEATH THE RECEPTACLE. OUTLETS THAT DO NOT SATISFY THESE SPECIFICATIONS ARE ACCEPTABLE PROVIDED THAT COMPARABLE OUTLETS, THAT PERFORM THE SAME FUNCTIONS, ARE PROVIDED WITHIN THE SAME AREA AND ARE ACCESSIBLE. (1136A.1) 4. CONTROLS OR SWITCHES INTENDED TO BE SED BY THE OCCUPANT OF THE ROOM OR AREA TO CONTROL LIGHTING AND RECEPTACLE OUTLETS, APPLIANCES, ALARMS, OR COOLING, HEATING AND VENTILATING EQUIPMENT, SHALL BE LOCATED NO MORE THAN 48 INCHES MEASURED FROM THE TOP OF THE OUTLET BOX NOR LESS THAN 15 INCHES MEASURED FROM THE BOTTOM OF THE OUTLET BOX TO THE LEVEL OF THE FINISHED FLOOR OR WORKING PLATFORM. IF THE REACH IS OVER A PHYSICAL BARRIER OR OBSTRUCTION BETWEEN 20 AND 25 INCHES IN DEPTH, THE MAX. HEIGHT IS REDUCED TO 44 INCHES FOR FORWARD APPROACH, OR 46 INCHES FOR SIDE APPROACH, PROVIDED THE OBSTRUCTION IS NO MORE THAN 24 INCHES IN DEPTH. PHYSICAL BARRIERS OR OBSTRUCTIONS SHALL NOT EXTEND MORE THAN 25 INCHES FROM THE WALL BENEATH THE CONTROL. CONTROLS THAT DO NOT SATISFY THESE SPECIFICATIONS ARE ACCEPTABLE PROVIDED THAT COMPARABLE CONTROLS OR OUTLETS, THAT PERFORM THE SAME FUNCTIONS, ARE PROVIDED WITHIN THE SAME AREA AND ARE ACCESSIBLE. (1136A.2) a. IN THE ATTICS, MANSARDS, OVERHANGS, FALSE FRONTS SET OUT FROM WALLS AND SIMILAR CONCEALED SPACES, AND IN FLOOR-CEILING ASSEMBLIES, DRAFT STOPS SHALL BE IN LINE WITH WALLS SEPARATING INDIVIDUAL DWELLING UNITS AND GUEST ROOMS FROM EACH OTHER AND FROM OTHER USES. b. DRAFT-STOPPING SHALL BE 1/2" GYPSUM BOARD, DRAFT-STOPPING MUST BE ADEQUATELY SUPPORTED. 8. THIS BUILDING AND GARAGE MUST BE EQUIPPED WITH AN AUTOMATIC FIRE EXTINGUISHING SYSTEM, COMPLYING WITH (NFPA-13 / NFPA-13R); THE SPRINKLER SYSTEM SHALL BE APPROVED BY PLUMBING DIC. PRIOR TO INSTALLATION. B. INTERIOR FINISHES AND FLAME RETARDANTS: 1. THE MAXIMUM FLAME SPREAD CLASS OF FINISH MATERIALS USED ON INTERIOR WALLS AND CEILINGS SHALL NOT EXCEED THAT SET FORTH IN TABLE ----. SMOKE DENSITY SHALL NOT BE GREATER THAN 450 WHEN TESTED IN ACCORDANCE WITH UBC STANDARD 8-1. 2. INTERIOR WALL AND CEILING FINISHES FOR ENCLOSED STAIRWAY SHALL NOT EXCEED A FLAMESPREAD CLASSIFICATION OF 25 (CLASS 1) AND A SMOKE DENSITY OF 150L. 3. ANY DECORATIONS USED SHALL BE NON-COMBUSTIBLE OR FLAME-RETARDANT TREATED IN AN APPROVED MANNER (CURTAINS, DRAPES, SHADES, HANGINGS, ETC.). 4. THE FLAME-SPREAD RATING OF PANELING MATERIALS ON THE WALLS OF THE CORRIDOR, LOBBY, AND EXIT ENCLOSURE MUST BE CLASS II. C. SIGNAGE: 1. STAIRWAY IDENTIFICATION SIGNS SHALL BE LOCATED AT EACH FLOOR LEVEL IN ALL ENCLOSED STAIRWAYS IN BUILDINGS FOUR OR MORE STORIES IN HEIGHT. 1. THE CONSTRUCTION DOCUMENTS ARE NOT INTENDED TO BE A COMPLETE SET OF INSTRUCTIONS ON HOW TO CONSTRUCT A BUILDING. CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES, AND SITE SAFETY PRECAUTIONS ARE CUSTOMARILY ASSIGNED AS RESPONSIBILITIES OF THE CONTRACTOR TO GIVE THE CONTRACTOR FULL LATITUDE IN PREPARING BIDS AND CARRYING OUT THE CONSTRUCTION PHASE. 2. OMISSIONS OR CONFLICTS BETWEEN THE DRAWINGS, NOTES, AND DETAILS, SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND RESOLVED BEFORE PROCEEDING WITH THE WORK. 3. NOTES AND DETAILS ON THE DRAWINGS SHALL TAKE PRECEDENCE OVER THES GENERAL NOTES. 1. PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A OR 2-A10BC WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS OF THE BUILDING ON EACH FLOOR, ALSO DURING CONSTRUCTION. 2. PROVIDE PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 10BC FOR KITCHEN, ELECTRICAL ROOM, MECHANICAL ROOM, AND ELEVATOR EQUIPMENT ROOM. 4. THE LOCATION OF FIRE DEPARTMENT HOSE CONNECTIONS SHALL BE APPROVED BY THE FIRE DEPARTMENT. 5. PROVIDE A COMPLETE SUPERVISED AUTOMATIC SPRINKLER SYSTEM THROUGHOUT THE BUILDING IN ACCORDANCE WITH ALL APPLICABLE CODES. NO WORK ON THIS SYSTEM SHALL BE STARTED PRIOR TO THE APPROVAL OF PLANS BY THE FIRE DEPARTMENT AND THE BUILDING DEPARTMENT PLUMBING SECTION. E. FIRE ALARM: 1. PROVIDE A COMPLETE AUTOMATIC FIRE ALARM AND DETECTION SYSTEM THROUGHOUT THE BUILDING IN ACCORDANCE WITH APPLICABLE CODES. 2. SUBMIT DRAWINGS OF FIRE ALARM SYSTEM TO FIRE DEPARTMENT FOR APPROVAL PRIOR TO INSTALLATION. 3. THIS BUILDING SHALL BE PROVIDED WITH A MANUAL ALARM SYSTEM WITH THE CAPABILITY TO SUPPORT VISIBLE ALARM NOTIFICATION APPLIANCES IN ACCORDANCE WITH NFPA 72 F. SPECIAL HAZARDS: 6. ALL DIMENSIONS ARE TO CENTER LINE OF STUD OR FACE OF STUD AS INDICATED. FACE OF WALL IS FACE OF CONCRETE/MASONRY, AND FACE OF FINISH MATERIAL, UNLESS NOTED OTHERWISE. 1. ROOF OBSTRUCTION SUCH AS TELEVISION ANTENNA, GUY WIRES, SOLAR PANELS, AND RAZOR RIBBON SHALL NOT PREVENT FIRE DEPARTMENT ACCESS OR EGRESS IN THE EVENT OF FIRE. 7. ALL DRAWINGS AND NOTES ARE COMPLEMENATRY, AND WHAT IS CALLED FOR BY ANY ONE WILL BE AS BINDING AS IF CALLED FOR BY ALL. 2. PROVIDE COLLISION BARRIERS ADEQUATE TO PROTECT CONTROL METERS, REGULATORS, AND PIPING FOR HAZARDOUS MATERIALS THAT ARE EXPOSED TO VEHICULAR DAMAGE. 8. WHERE THERE ARE CONFLICTS BETWEEN DRAWINGS, THE MOST STRINGENT CONDITIONS SHALL GOVERN. 3. ROOF COVERING SHALL BE FIRE RETARDANT. 4. PARKING SPACES SHALL NOT OBSTRUCT REQUIRED EXITS. 9. ALL REQUESTS FOR CLARIFICATION OF THESE DRAWINGS SHALL BE DIRECTED TO THE ARCHITECT IN WRITING. 10. WORK AND EQUIPMENT INDICATED "BY OTHERS" ARE PART OF THIS CONTRACT AND TO BE PROVIDED BY OTHER TRADES OR GENERAL CONTRACTOR. 11. WHERE WORK AND EQUIPMENT IS INDICATED "NOT IN CONTRACT" (N.I.C.), SUCH WORK AND/OR EQUIPMENT SHALL BE PROVIDED BY OWNER, THE CONTRACTOR SHALL COORDINATE AND COOPERATE TO EFFECT SUCH INSTALLATION. D. CONTRUCTION: 1. CONTRACTOR IS RESPONSIBLE FOR PROVIDING TEMPORARY ERECTION BRACING AND SHORING AS REQUIRED ON ALL BEAMS, WALLS, ETC., ADEQUATE TO PROVIDE FULL STRUCTURAL STABILITY AND SAFETY. BRACING SHALL NOT BE REMOVED UNITIL THE ELEMENTS ARE FULLY CONNECTED AND ARE CAPABLE OF SUPPORTING THE DESIGN LOADING. 2. EXCAVATION NOT WITHSTANDING ANY PROVISIONS IN THE SPECIAL CONDITIONS, GENERAL CONDITIONS OR ANY OTHER MATTERS SPECIFIED IN THE PLANS AND SPECIFICATIONS. THE ARCHITECT MAKES NO REPRESENTATION OR WARRANTY AS TO THE ACCURACY OF THE DATA, THE SOIL AND ROCK MATERIALS ENCOUNTERED, OR THE DIFFICULTY OF EXCAVATION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FAMILIARIZING HIMSELF AS TO THE TYPE, NATURE, AMD QUANTITIES OF ALL MATERIALS TO BE EXCAVATED. ALL TRENCHING AND EXCAVATING, REGARDLESS OF MATERIALS ENCOUNTERED, EQUIPMENT, OR METHODS REQUIRED FOR EXCAVATION, WILL BE UNCLASSIFIED AND THE COST THEREOF SHALL BE CONSIDERED AS BEING INCLUDED IN THE LUMP SUM BID. NO EXTRA PAYMENT OR CHANGE ORDERS WILL BE ALLOWED FOR EXCAVATION. 3. PROVIDE CONCEALED BLOCKING/BACKING AS REEQUIRED FOR ALL WALL MOUNTED EQUIPMENT. 6. MAINTAIN 8" CLEAR BETWEEN GYPSUM BOARD JOINTS AND CORNERS OF ANY OPENINGS, WINDOWS, AND DOORS. MAINTAIN A MINIMUM " CLEAR BETWEEN FLOOR AND BOTTOM OF GYPSUM BOARD. N R O FO CTI T U O N TR S N CO ARCH SED IT N E LLIA M WI C-17744 REN 11 30 13 TE R OF CALIFO 5. CONSPICUOUSLY MARK GAS SHUTOFF VALVE. G. BUILDING ADDRESS: 1. BUILDING ADDRESS SHALL BE PROVIDED AT OR NEAR THE ENTRANCE OF THE BUILDING IN ACCORDANCE TO APPLICABLE CODE. H. EXITING: 1. THE PATH OF EXIT TRAVEL TO AND WITHIN EXITS IN THIS BUILDING SHALL BE IDENTIFIED BY EXIT SIGNS, EXIT SIGNS SHALL BE READILY VISIBLE FROM ANY DIRECTION OF APPROACH. EXIT SIGNS SHALL BE LOCATED, AS NECESSARY TO CLEARLY INDICATE THE DIRECTION OF EGRESS TRAVEL NO POINT SHALL BE MORE THAN 100 FEET (30.480 m) FROM THE NEAREST VISIBLE SIGN. 2. EXIT SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED. WHEN THE FACE OF AN EXIT SIGN IS ILLUMINATED FROM AN EXTERNAL SOURCE, IT SHALL HAVE AN INTENSITY OF NOT LESS THAN 5 FOOT CANDLES (54 LUX)FROM EITHER OF 2 ELECTRICAL LAMPS. INTERNALLY ILLUMINATED SIGNS SHALL BE LISTED AND LABELED AND SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS AND SECTION 2702. 3. THE EXIT SIGNS SHALL ALSO BE CONNECTED TO AN EMERGENCY ELECTRICAL SYSTEM PROVIDED FROM STORAGE BATTERIES, UNIT EQUIPMENT OR AN ON-SITE GENERATOR SET, AND THE SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH ELECTRICAL CODE. 4. THE POWER SUPPLY FOR MEANS OF EGRESS ILLUMINATION SHALL NORMALLY BE PROVIDED BY THE PREMISES' ELECTRICAL SUPPLY. IN THE EVENT OF POWER SUPPLY FAILURE, AND EMERGENCY ELECTRICAL SYSTEM SHALL AUTOMATICALLY ILLUMINATE THE FOLLOWING AREAS: a. AISLES AND UNENCLOSED EGRESS STAIRWAYS IN ROOMS AND SPACES THAT REQUIRE TWO OR MORE MEANS OF EGRESS; b. CORRIDORS, EXIT ENCLOSURES AND EXIT PASSAGEWAYS IN BUILDINGS REQUIRED TO HAVE TWO OR MORE EXITS; c. EXTERIOR GLASS COMPONENTS AT OTHER THAN THE LEVEL OF EXIT DISCHARGE UNTIL EXIT DISCHARGE IS ACCOMPLISHED FOR BUILDINGS REQUIRED TO HAVE TWO OR MORE EXITS; d. INTERIOR EXIT DISCHARGE ELEMENTS, AS PERMITTED IN SECTION 1027.1, IN BUILDINGS REQUIRED TO HAVE TWO OR MORE EXITS; e. EXTERIOR LANDINGS, AS REQUIRED BY SECTION 1008.1.6, FOR EXIT DISCHARGE DOORWAYS IN BUILDINGS REQUIRED TO HAVE TWO OR MORE EXITS. TITLE SHEET ISSUE 7/29/13 5. EGRESS DOORS SHALL BE READILY OPENABLE FROM EGRESS SIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. FLUSH BOLTS OR SURFACE BOLTS ARE PROHIBITED (APPLIES ALSO TO EXIT GATES). THE UNLATCHING OF ANY LEAF SHALL NOT REQUIRE MORE THAN ONE OPERATION. 6. EXIT SIGNS SHALL BE ILLUMINATED AT ALL TIMES. DESIGNED 7. EXIT SIGNS SHALL BE CONNECTED TO AN EMERGENCY POWER SYSTEM THAT WILL PROVIDE AN ILLUMINATION OF NOT LESS THAN 90MIN. IN CASE OF PRIMARY POWER LOSS. (1011.2-1011.5.3) 8. EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY, SPECIAL KNOWLEDGE, OR EFFORT. FLUSH BOLTS OR SURFACE BOLTS ARE PROHIBITED (APPLIES ALSO TO EXIT GATES). 9. ALL EGRESS DOOR OPERATION SHALL ALSO COMPLY WITH SECTION 1008.1.9-1008.1.9.7 CHECKED 10. THE MEANS OF EGRESS INCLUDING THE EXIT DISCHARGE, SHALL BE ILLUMINATED AT ALL TIMES THE BUILDING SPACE SERVED BY THE MEANS OF EGRESS IS OCCUPIED. THE MEANS OF EGRESS ILLUMINATION LEVEL SHALL NOT BE LESS THAN 1FOOT-CANDLE AT THE WALKING SURFACE. (1006.1) DATE 10. CONTINUOUS DRYWALL IS REQUIRED BEHIND AND AROUND ALL ELECTRICAL SERVICE PANELS, FIRE EXTINGUISHERS AND MEDICINE CABINETS. 11. PROVIDE A WEEP SCREED FOR STUCCO AT THE FOUNDATION PLTE LINE A MINIMUM OF 4" ABOVE THE EARTH OR 2" ABOVE PAVED AREAS. WEEP SCREEDS SHALL BE OF A TYPE WHICH ALLOW TRAPPED WATER TO DRAIN TO THE EXTERIOR OF THE BUILDING. 12. PROVIDE ADDITIONAL FURRING OR MEMBRANE LAYERS AS REQUIRED TO ALIGN SURFACES OF CONTIGUOUS WALLS OF VARYING THICKNESS. 13. RODENT AND CORROSION PROOF SCREENS SHALL BE INSTALLED ON ALL PENETRATIONS INTO THE BUILDING ENVELOPE. DATE ISSUE FOR BID 7. THE PATH OF EXIT TRAVEL TO AND WITHIN EXITS IN THIS BUILDING SHALL BE IDENTIFIED BY EXIT SIGNS. EXIT SIGNS SHALL BE READILY VISIBLE FROM ANY DIRECTION OF APPROACH. EXIT SIGNS SHALL BE LOCATED, AS NECESSARY, TO CLEARLY INDICATE THE DIRECTION OF EGRESS TRAVEL. NO POINT SHALL BE MORE THAN 100 FEET (30,480 mm) FROM THE NEAREST VISIBLE SIGN. 9. CONTINUOUS DRYWALL BEHIND ALL TUBS IS REQUIRED. BR D. FIRE PROTECTION EQUIPMENT: 4. TYPICAL DETAILS SHOWN SHALL APPLY WHERE NO SPECIAL DETAIL IS SHOWN. 5. WRITTEN DIMENSIONS (NOT SCALED DIMENSIONS) SHALL BE USED. DO NOT SCALE DRAWINGS. ONYX ARCHITECTS 316 N. Sierra Madre Blvd. Pasadena, California 91107 V.626.405.8001 F.626.405.8150 www.onyxarchitects.com 2. ALL EXIT CORRIDORS SHALL BE PROVIDED WITH FLOOR-LEVEL EXIT SIGNS WHEREVER EXIT SIGNS ARE REQUESTED, IN COMPLIANCE WITH UBC ---------. 3. PROVIDE FIRE EXTINGUISHER AS REQUIRED BY FIRE DEPARTMENT FIELD INSPECTOR. 5. PROPERLY PREPARE AND READY ALL SURFACES PRIOR TO INSTALLING FINISH MATERIALS. AD-1 A0.0 A0.1 A0.2 A0.3 A1.0 A1.1 A2.0 A3.0 A4.1 A4.2 A7.1 A7.2 A8.1 A8.2 b. IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES, AT 10-FOOT INTERVALS ALONG THE LENGTH OF THE WALL. C. DRAWINGS: 4. ALL WALL PARTITIONS SHALL EXTEND TO THE STRUCTURE ABOVE UNLESS OTHERWISE NOTED. SHEET INDEX a. IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES, AT THE CEILING AND FLOOR LEVELS. N OW ----- AND ANGLE @ AT CL CENTERLINE O DIAMETER ROUND OR PHASE # POUND OR NUMBER A.B ANCHOR-BOLT A/C AIR CONDITIONING ACOUS. ACOUSTICAL A.C.T. ACOUSTICAL TILE A.D. AREA DRAIN ADJ. ADJUSTABLE A.F.F. ABOVE FINISH FLOOR AGGR. AGGREGATE ALT. ALTERNATE ALUM. ALUMINUM APPROX. APPROXIMATE ARCH. ARCHITECTURAL/ARCHITECT ASB ASBESTOS ASPH. ASPHALT A ST ----- & T EC SITE / PROJECT DATA --- 4. SHOWER COMPARTMENTS AND WALLS ABOVE BATHTUBS WITH INSTALLED SHOWER HEADS SHALL BE FINISHED WITH A SMOOTH, NONABSORBENT SURFACE TO HEIGHT NOT LESS THAN 70 INCHES ABOVE THE DRAIN INLET. SECTION 1210.3 USE OF WATER-RESISTANT GYPSUM BACKING BOARD SHALL BE AS STATED IN SECTION 2509.3 A PROGRAM SUMMARY: --- 5. A FIRE ALARM SYSTEM IS REQUIRED FOR THIS STRUCTURE. PLANS FOR THE ALARM SYSTEM MUST BE SUBMITTED TO THE FIRE DEPARTMENT FOR APPROVAL PRIOR TO INSTALLATION. 5. STEEL COLUMNS SHALL BE INDIVIDUALLY PROTECTED, INCLUDING FURRED SPACES, AT THE CEILING AND FLOOR LEVELS. 1403 Kenneth Rd., Suite B Glendale, CA 91201-1421 P 818-956-8101 F 818-956-0120 4030 GSF - 3. PROVIDE ULTRA LOW FLUSH WATER CLOSETS FOR ALL NEW CONSTRUCTION. 4. PLASTIC ELECTRICAL BOXES ARE TO BE CLEARLY IDENTIFIED AS APPROVED FOR 1-HOUR CONSTRUCTION. a. Class A roof covering is required for all buildings. Wood shakes and shingles are not permitted. (7207.4, 1505) b. Valley flashings shall be not less than 0.019-inch (0.48 mm) (No. 26 galvanized sheet gage) corrosion-resistant metal installed over a minimum 36-inch-wide (914mm) underlayment consisting of one layer of No. 72 ASTM cap sheet running the full length of the valley (704A.1.3) c. Roof gutters shall be provided with the means to prevent the accumulation of leaves and debris in the gutter (704A.1.5) d. (Roof) (Attic)(Exterior wall) vents shall resist the intrusion of flame and embers into the attic area of the structure, or shall be protected by corrosion-resistant, noncombustible wire mesh with 1/4 -inch (6 mm) openings or its equivalent. Vents shall not be installed in eaves and cornices (704A.2.1, 704A3.2.1, 704A.2.2, 7207.3) e. Eaves and soffits shall meet the requirements of SFM 12-7A-3 or shall be protected by ignition-resistant materials or noncombustible construction on the exposed underside (704A.2.3) f. Exterior walls shall be approved noncombustible or ignition-resistant material, heavy timber, or log wall construction or shall provide protection from the intrusion of flames and embers in accordance with standard SFM 12-7A-1 (704A.3.1) g. Exterior wall coverings shall extend from the top of foundation to the roof, and terminate at 2-inch (50.8 mm) nominal solid wood blocking between rafters at all roof overhangs, or in the case of enclosed eaves, terminate at the enclosure (704A.3.2) h. Exterior windows, window walls, glaze doors, and glazed openings within exterior doors shall be insulating- glass units with a minimum of one tempered pane, or glass block units, or have a fireresistance rating of not less than 20 minutes, when tested according to ASTM E 2010, or conform to the performance requirements of SFM 12-7A-2 (704A.3.2.2) i. Exterior door assemblies shall conform to the performance requirements of standard SFM 12-7A-1 or shall be approved noncombustible construction, or solid core wood having stiles and rails not less than 1 3/8 inches thick with interior field panel thickness no less than 1 ¼ inches thick, or shall have a fire-resistance rating of not less than 20 minutes when tested according to ASTM E 2074. (Exception: Noncombustible or exterior fire-retardant treated wood vehicle access doors) (704A.3.2.3) j. Decking, surfaces, stair treads, risers, and landings of decks, porches, and balconies where any portion of such surface is within 10 feet (3048 mm) of the primary structure shall be constructed of heavy timber, non combustible or other approved materials per Sec.704A.4.1 k. The underside of cantilevered and overhanging appendages and floor projections shall maintain the ignition- resistant integrity of exterior walls, or the projection shall be enclosed to the grade (704A.4.2.1) l. Buildings shall have all underfloor areas completely enclosed to the grade with construction as required for exterior walls (704A.4.2.2, 7207.1) m. All utilities, pipes, furnances, water heaters or other mechanical devices located in an exposed under-floor area of a residential building shall be enclosed with materials as required for 1-hour fire-resistive construction.(7207.2) n. The space between the roof covering and roof decking shall be constructed to prevent the intrusion of flames and embers and be fire stopped per 704A.1.2. o. No trellis is permitted within 10 feet of the primary structure. p. Trellis more than 10 feet from the primary structure shall be constructed of heavy timber or non combustible materials. Minimum of 4 inches spacing is required between the members. (Information Bulletin No. P/BC 2008-023). NI BUILDING AREA: - 4. THE CONTRACTOR SHALL PREPARE AND SUBMIT COPIES OF THE FIRE SPRINKLER SYSTEM TO THE FIRE DEPARTMENT FOR APPROVAL PRIOR TO INSTALLATION. 3. ALL PENETRATIONS OF FIRE-RESISTANT WALLS SHALL BE PROTECTED BY APPROVED FIRE STOP SYSTEM. Landscape Architecture Planning Urban Design ----- ----- GSF 2. AN APPROVED SEISMIC GAS SHUTOFF VALVE WILL BE INSTALLED ON THE FUEL GAS LINE ON THE DOWN STREAM SIDE OF THE UTILITY METER AND BE RIGIDLY CONNECTED TO THE EXTERIOR OF THE BUILDING OR STRUCTURE CONTAINING THE FUEL GAS PIPING. 2. ALL PLUMBING PENETRATION THROUGH WALLS WHICH REQUIRED PROTECTED OPENINGS (OCCUPANCY SEPERATION WALLS, CORRIDOR WALLS AND WALLS TO CLOSE A REAL OR IMAGINARY PROPERTY LINE) ARE REQUIRED TO BE GALVANIZED OR CAST IRON PIPING. G. VERY HIGH FIRE HAZARD SEVERITY ZONE (VHFHSZ) ( 701A.3.2, 7201.2, 7207) 1. Based on City maps, this project is located within Very High Fire Hazard Severity Zone (VHFHSZ). It shall Comply with requirements of Materials, systems & construction methods of Chapter 7A and Chapter 72. Add the following material specifications and/or notes/ details to plans: Nature Education Facilities, Gardens & Trails 10459 Tuxford Street Sun Valley, CA 91352-2126 FIRE SPRINKLER SYSTEM: TOTAL BUILDING (GSF): 1. RECESSED EQUIPMENT AND FIXTURES AT FIRE RESISTANT WALLS, FLOORS AND CEILINGS MUST BE BOXED AROUND WITH 5/8" TYPE "X" DRYWALL TO MAINTAIN THE RATED ASSEMBLY. Troller Mayer Associates, Inc. A3 + B TYPE 5-B ----- GSF 1. THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOT CLEAR AND UNOBSTRUCTED ACCESS TO ANY WATER OR POWER DISTRIBUTION FACILITES (POWER POLES, PULL-BOXES, TRANSFORMERS, VAULTS, PUMPS, VALVES, METERS, APPURTENANCES, ETC.) OR TO THE LOCATION OF THE HOOK-UP. THE CONSTRUCTION SHALL NOT BE WITHIN TEN FEET OF ANY POWER LINES-WHEATHER OR NOT THE LINES ARE LOCATED ON THE PROPERY. FAILURE TO COMPLY MAY CAUSE CONSTRUCTION DELAYS AND/OR ADDITIONAL EXPENSES. LIC OCCUPANCY TYPE: CONSTRUCTION TYPE: BUILDING FOOTPRINT: 1. THE CONSTRUCTION SHALL BE IN CONFORMANCE WITH THE CODES LISTED ON FRONT PAGE. 6. FIRE BLOCKING MUST BE PROVIDED IN ACCORDANCE WITH SECTION 717 IN THE FOLLOWING LOCATIONS: BUILDING SUMMARY LEGAL DESCRIPTION: A. FIRE RESISTIVE CONSTRUCTION DAL E ABBREVIATIONS 2011 LOS ANGELES BUILDING CODE (2010 CBC / 2009 IBC w/ amendments) 2011 LOS ANGELES MECHANICAL CODE (2010 CMC / 2009 UMC w/ amendments) 2011 LOS ANGELES PLUMBING CODE (2010 CPC / 2009 UPC w/ amendments) 2011 LOS ANGELES ELECTRICAL CODE (2010 CEC / 2008 NEC w/ amendments) 2010 CALIFORNIA FIRE CODE (2009 IFC w/ amendments) 2011 CALIFORNIA GREEN BUILDING CODE (2010 Title 24 part 11 w/ amendments) ZONING: E. BUILDING CODE: 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL WORK AND MATERIALS IN CONFORMANCE WITH ANY CODE OR CODES OF FEDERAL, STATE, COUNTY, OR MUNICIPALITY HAVING JURISDICTION OVER SUCH WORK. ALL APPLICABLE REQUIREMENTS IN THESE REGULATIONS SHALL BE FOLLOWED THE SAME AS IF NOTED IN THE DRAWINGS. CONFLICTS BETWEEN WORK SET FORTH ON THE DRAWINGS AND BUILDING CODES SHALL BE SUBMITTED TO THE ARCHITECT FOR RESOLUTION PRIOR TO PROCEEDING WITH THE WORK. CODE SUMMARY SPECIFIC PLAN: A. CODE REQUIREMENTS: 2. O.S.H.A. PERMIT IS REQUIRED FOR EXCAVATIONS OVER FIVE (5) FEET. THE CONTRACTOR SHALL OBTAIN PERMIT PRIOR TO STARTING WORK. 10459 Tuxford St. Sun Valley, CA 91352 FIRE PROTECTION NOTES Theodore Payne Foundation C:\Users\JDeveau\Documents\P11040_Theodore Payne_CENTRAL_JDeveau.rvt THEODORE PAYNE FOUNDATION GENERAL NOTES 8. DOOR HANDLES. LOCK AND OTHER OPERATING DEVICES SHALL BE INSTALLED AT A MIN. 34" AND A MAX. 48" ABOVE FINISHED FLOOR 11. THE EMERGENCY POWER SYSTEM SHALL PROVIDE POWER FOR A DURATION OF NOT LESS THAN 90 MINUTES AND SHALL CONSIST OF STORAGE BATTERIES, UNIT EQUIPMENT OR AN ON-SITE GENERATOR. THE INSTALLATION OF THE EMERGENCY POWER SYSTEM SHALL BE IN ACCORDANCE WITH SECTION 2702. (1006.3) DRAWN SK MKC SK 7/29/13 SCALE JOB NO. 12. EMERGENCY LIGHTING FACILITIES SHALL BE ARRANGED TO PROVIDE INITIAL ILLUMINATION THAT IS AT LEAST AN AVERAGE OF 1FOOT-CANDLE (11 LUX) AND A MINIMUM AT AN POINT OF 0.1 FOOT CANDLE (1 LUX) MEASURED ALONG THE PATH OF EGRESS AT FLOOR LEVEL. ILLUMINATION LEVELS SHALL BE PERMITTED TO DECLINE TO 0.6 FOOT CANDLE (6 LUX) AVERAGE AND A MINIMUM AT ANY POINT OF 0.06 FOOT-CANDLE (0.6 LUX) AT THE END OF THE EMERGENCY LIGHTING TIME DURATION. A MAXIMUM-TO-MAXIMUM ILLUMINTATION UNIFORMITY RATIO OF 40 TO 1 SHALL NOT BE EXCEEDED. P11040 SHEET A0.0 OF SHEETS