Mkondeni Technical Evaluation Criteria 1.1 Mandatory Technical Evaluation Criteria Mandatory Technical Evaluation Criteria Description Criteria PV System Performance Designed system installed DC capacity The PV system installed capacity must be equal to or greater than 320 kWp and less or equal to 329 kWp Guaranteed performance ratio The Tenderer must provide a minimum guaranteed Performance Ratio during first year operation period equal to or greater than 77.4% Guaranteed annual average plant availability 98% Contractor’s Capability and Track Record PV experience Minimum of at least 1 roof top PV installations equal to or greater than 20 kWp. The Tenderer must provide specific details of the installation including: site location, installed capacity, date of commercial operation, PV module technology, site photograph, As built drawings (if available) and testimonials from clients (if available). PV Modules Technology MKONDENI TECHNICAL EVALUATION CRITERIA REV 1 GE Crystalline silicon (Mono or Poly) Page 1 of 4 Mandatory Technical Evaluation Criteria Description Criteria Track record The module manufacturer shall be Tier 1 manufacturer. Tier 1 in this context refers to the Tier 1 list of Bloomberg New Energy Finance and the Tier 1 list of Photon International, both in the version as of the date of publishing of the tender documents. Locally assembled modules shall be considered Tier 1 if there is a clear train to one of the manufacturers of the BNEF/Photon Tier 1 lists Inverters Inverter Concept String inverter Special Certification NRS-097-2-1:2010 Edition 1 Track record The inverter manufacturer must have at least 3 years of experience in PV market and must have at least 500 kW reference projects for similar offered size inverter. PV Mounting Structure PV structure mounting Fixed mounted type and solutions of installation to be provided. Metering Meters List of provided approved energy meters must be used for the Project Tenders which do not meet mandatory technical requirements will not be evaluated further. Tenderers to provide proof for each item. This information is mandatory for quality and licensing. MKONDENI TECHNICAL EVALUATION CRITERIA REV 1 GE Page 2 of 4 1.2 Qualitative Technical Evaluation Criteria: The Tenderer’s technical evaluation will only be performed if the bidder complies with the mandatory technical requirements mentioned above. The technical requirements and their evaluation weight percentage are presented in a table below. The detail technical requirements on each of the technical parameters are presented in the work information document. Tenderers to provide an Engineering proposal that covers the items below in detail. Technical Parameter % Plant Performance 25 Civil and Infrastructure 10 Electrical System 25 Control and Monitoring 15 Inspection, Test and Commissioning 10 Operation and Maintenance 10 Contractor’s Track Record 5 Total 100% Minimum Score is 70% MKONDENI TECHNICAL EVALUATION CRITERIA REV 1 GE Page 3 of 4 MKONDENI TECHNICAL EVALUATION CRITERIA REV 1 GE Page 4 of 4