Leben im Bad Living bathrooms Vero # VE 099C 35 800-1000 35 Follow all other installation instructions! X 100 50 Installation instructions 100 100 2x # UV 9903 Instructions for use The bathroom furniture range complies with the standards and guidelines applicable at the time of delivery and is designed for use in bathrooms. Direct contact with water should be avoided, for example, when showering. The console is not suitable for installation from below with semi built-in and built-in washbasins. A power supply of 110 V – 230 V must be available on site. Ceramics wider than 600 mm must be fixed to the wall. We reserve the right to make technical improvements and design modifications to the products illustrated. MAL_Vero_VE099C/14.10.2 1 2 3 4 230 V Ø 8 mm 2x 5 6 7 8 xx 0- 10 11 12 13 14 15 16 17 18 19 20 Best.-Nr. VE099C/14.10.2 9 mm Duravit AG, Werderstr. 36, 78132 Hornberg, Germany, Phone +49 78 33 700, Fax +49 78 33 70 289, info@duravit.de, www.duravit.de MAL_Vero_VE099C/14.10.2 Leben im Bad Living bathrooms Vero # VE 099C Installation instructions 35 V X 100 80 1001-1400 35 100 100 35 V X 100 80 1001-1400 35 100 1x 2x 100 32 32 V 1001-1400 32 32 32 32 100 30 1x # UV 9902 2x # UV 9903 X 3x 30 70 70 30 3x # UV 9926 V = according to the panel specification Follow all other installation instructions! Instructions for use The bathroom furniture range complies with the standards and guidelines applicable at the time of delivery and is designed for use in bathrooms. Direct contact with water should be avoided, for example, when showering. The console is not suitable for installation from below with semi built-in and built-in washbasins. A power supply of 110 V – 230 V must be available on site. Ceramics wider than 600 mm must be fixed to the wall. We reserve the right to make technical improvements and design modifications to the products illustrated. MAL_Vero_VE099C/14.10.2 1 2 3 4 5 230 V Ø 8 mm 3x 6 7 8 9 10 xx 0- mm 11 12 13 14 15 1 2 3 4 5 230 V Ø 14 mm 6x 6 7 8 9 10 xx 0- 12 13 29 30 Best.-Nr. VE099C/14.10.2 11 mm Duravit AG, Werderstr. 36, 78132 Hornberg, Germany, Phone +49 78 33 700, Fax +49 78 33 70 289, info@duravit.de, www.duravit.de MAL_Vero_VE099C/14.10.2 Leben im Bad Living bathrooms Vero # VE 099C Installation instructions 35 V V X 100 80 1401-2000 35 100 100 35 V V X 100 80 1401-2000 35 100 2x 2x 100 32 32 V 1401-2000 32 32 32 32 V 32 32 100 30 2x # UV 9902 2x # UV 9903 X 4x 30 70 70 30 4x # UV 9926 V = according to the panel specification Follow all other installation instructions! Instructions for use The bathroom furniture range complies with the standards and guidelines applicable at the time of delivery and is designed for use in bathrooms. Direct contact with water should be avoided, for example, when showering. The console is not suitable for installation from below with semi built-in and built-in washbasins. A power supply of 110 V – 230 V must be available on site. Ceramics wider than 600 mm must be fixed to the wall. We reserve the right to make technical improvements and design modifications to the products illustrated. MAL_Vero_VE099C/14.10.2 1 2 3 4 5 230 V Ø 8 mm 4x 6 7 8 9 10 xx 0- mm 11 12 13 14 15 1 2 3 4 5 230 V Ø 14 mm 8x 6 7 8 9 10 xx 0- 12 13 29 30 Best.-Nr. VE099C/14.10.2 11 mm Duravit AG, Werderstr. 36, 78132 Hornberg, Germany, Phone +49 78 33 700, Fax +49 78 33 70 289, info@duravit.de, www.duravit.de MAL_Vero_VE099C/14.10.2 Leben im Bad Living bathrooms Mounting instructions for bathroom furniture with a power supply Safety 2 Electrical installation 3 Mounting 4 Safety Intended use Safety instructions The mounting instructions come as part of the Duravit product and are aimed at people who carry out the electrical installation for the product. You must read through the mounting instructions carefully and they must be available at all times. Danger to life Contact with electricity may lead to an electric shock. >> Carry out the electrical installation in accordance with the national, European and international directives and standards. >> Observe protection zones for wet rooms in accordance with country-specific standards, local regulations and low voltage guidelines. >> Connect the electrics using a ground fault circuit interrupter (GFCI) in wet rooms or other specially equipped rooms. >> Disconnect electrical components from the power supply before the installation. >> Check that all components are de-energised. >> Prevent the power supply from being switched on accidentally. Target readership and qualifications The electrical installation may only be carried out by qualified electricians. Protection rating of Duravit products The protection rating of Duravit products with a power supply complies with the IP 44 standard as a minimum. Protection class of wall lights Protection class Connecting cable I H05VV-F, 3x 1.5 mm II H03VV-F, 2x 0.75 mm2 2 Standards and directives Duravit products comply with the CE marking directives: Penetration of foreign bodies and water Foreign bodies or water in equipment lead to a short circuit that may cause damage to the product. >> Observe the protection zones for Duravit products. Protection zones 0 60 A 0 60 1 Icons and symbols B Meaning This symbol highlights useful and important information. s Seconds > Action required 2250 Symbol 2 0 A A mirror cabinet with an IP 44 rating may protrude into zone 2. B A socket in a mirror cabinet must be mounted outside the zones. 2 MAL_51240/16.03.1 Electrical installation Electrical installation for protection class I Electrical connection L N Optional connection of an external button L N L' Electrical installation for protection class II Electrical connection L N L N Optional connection of an external button L N L' MAL_51240/16.03.1 3 Mounting Duravit AG · P.O. Box 240 · Werderstr. 36, 78132 Hornberg, Germany · Phone +49 7833 70 0 · Fax +49 7833 70 289 · info@duravit.com · www.duravit.com Measuring mode The control unit has a measuring mode. Once the measuring mode is active, the light is switched on again automatically 90 seconds after it has been switched off. The measuring mode may be triggered during an installation under voltage by accidentally actuating the touch LED/infrared switch continuously. >65 s The light flashes 6 times. >> Actuate the touch LED/infrared switch again for more than 65 seconds to deactivate the measuring mode. Use a reflective object (paper) for the infrared switch. The light flashes 4 times. 4 MAL_51240/16.03.1 Order no. 51240/16.03.1 We reserve the right to make technical improvements and enhance the appearance of the products shown >> Actuate the touch LED/infrared switch for longer than 65 seconds to activate the measuring mode. Use a reflective object (paper) for the infrared switch.