T O K I S TA R L I G H T I N G INSTRUCTION MANUAL TokiLux Series 24 VDC or 24 VAC TM General Description Tokistar’s TokiLux Series may be operated at 24 VDC or 24 VAC. Light Bars are installed end-to-end within the TokiLux track. Each Light Bar contains five LEDs and consumes a total of 4 watts. An individual run length may contain up to 24 Light Bars. Each track is labeled with wattage and operating voltage. Light Bar TokiLux Track Multiple Length Assembly Any run length exceeding 12 Light Bars will be supplied as multiple lengths to be joined. TokiLux Track Light Bar Retainer Clips Maximum Run Length Maximum 24 Light Bars PRECAUTIONS 1. Read all instructions completely before beginning installation. 2. Turn off electricity before beginning installation. 3. All wiring is to be performed by a qualified electrician. 4. Installation must comply with the National Electrical Code, and all applicable codes. 5. Turn main supply to the Power Supply on only after all connections have been made and tested. 6. Use only LED Drivers or Transformers provided by Tokistar with the system. TOKISTAR® LIGHTING 1015 E. Discovery Lane Anaheim, CA 92801 TEL: 714 772 7005 FAX: 714 772 7014 email: info@tokistar.com Website: tokistar.com Version 1.3 TokiLux Installation Instructions Page 2 TM Connectors Feed Connector Part#:TLX-CON Feed Connectors bring power to one end of a TokiLux run. Up to 24 Light Bars can be powered from a single connector. Flex Connector Part#: TLX-FLC Flex Connectors with 2" wires are used to turn corners and enable smaller sections of TokiLux to conform to curves. Do Not Snap Connectors in place from above. Slide in place. Retainer Clips Retainer clips are included with Feed Connectors, Flex Connectors and fixtures exceeding 12 Light Bars. These snap onto the fixture to provide a secure connection. Feed Connector Assembled A Retainer Clip is required between the 4th and 5th LED of the 1st Light Bar Flex Connector Assembled Retainer Clip on Feed Connector Retainer Clips snap in place from above. End Cap Part #: TLX-ED End Caps insulate the end of a run of TokiLux. Retainer Clips Mounting Clamp Part #: TLX-CP Mounting clamps are attached with screws and the Tokilux fixture is snapped in place. Recommended spacing is Mounting Clamp every 12". TokiLux Installation Instructions Page 3 TM Secondary Circuit Wiring A maximum of 24 Light Bars can be powered on one circuit from the power supply. Secondary Circuit Limit Do Not Exceed 4 Amps (96 watts @ 24 VDC or 24 VAC) Recommended Lead Wire Size The distance from the power supply to the fixture, and the load of the fixture, will determine the proper size of secondary wire. Feed Connectors are provided with a 6' lead. If additional wire needs to be attached to the Feed Connector, refer to the recommendations in this chart. Additional Secondary Lead 6' Factory Lead Secondary Lead Wires Wire Size Wire Length #16 AWG 50' (15 M) #14 AWG 75' (23 M) #12 AWG 100' (30 M) #10 AWG 150' (46 M) Power Supply Splice LED Driver Installation LDR24-4A This 96 Watt Class 2 LED Driver converts an AC input into a 24 VDC output. Refer to the manual provided with the LED Driver for detailed installation instructions. Part# LDR24-4A Input Volts 100~277 Output Volts 24 VDC Output Ratings 1 @ 4 Amps LDR24-192 Tokistar’s LDR24-192 has two independent 96 watt outputs. If the system is dimmed, each of the outputs requires an independent dimmer pack. This unit has wiring compartments for splicing on input and output leads, and can be connected directly to conduit. Refer to the manual provided with the LED Driver for detailed installation instructions. Part# LDR24-192 Input Volts 100~277 Output Volts 24 VDC Output Ratings 2 @ 4 Amps TokiLux Installation Instructions Page 4 TM LC-1CH-MULTI Dimming System Dimmer Pack - Part #: LC-1CH-MULTI Each dimmer pack receives 24 VDC from an LED Driver. The LDR24-192 LED Driver has two independent 96 watt outputs. Each output requires an independent dimmer pack. DMX Mode - Each unit is independently addressable. Up to 36 dimmer packs may be connected in series. For applications exceeding 36 dimmer packs, an additional feed from the DMX dimmer is required. The additional feed(s) can be sent directly from the dimmer, or you may use DMX Splitters. Consult factory on details of DMX Splitters. Analog Modes - For operation from devices using 0/1-10VDC protocol, up to 10 dimmer packs may be connected in series. For applications exceeding 10 dimmer packs, an additional feed from the analog dimming device is required. Manual Mode - You may select a light intensity the fixtures will operate at. In this case, no external dimming device is required. DMX Wiring Diagram DMX Console Fixture Fixture 0-24 VDC 0-24 VDC Dimmer Pack Dimmer Pack LED Driver 24 VDC 24 VDC DMX Out DMX In LED Driver DMX Out Analog Dimmer 0/1-10 VDC Wiring Diagram Fixture Fixture Analog Out Analog Out 0-24 VDC 0-24 VDC Dimmer Pack 24VDC For further information, refer to the instruction manual provided with the LC-1CH-MULTI. Dimmer Pack 24VDC LED Driver LED Driver Dual output LED drivers require a dimmer pack for each output. LC Dimming System Wall Dimmer - Part #: LC-DMR Power to the remote wall dimmer is provided from the LED Driver powering the first Dimmer Pack. A 50 foot CAT5 cable is provided. Dimmer Pack - Part #: LC-1CH-DP Each dimmer pack receives 24 VDC from an LED Driver. A CAT5 cable is provided with each unit. Up to 25 dimmer packs may be connected in series if the total length of all CAT5 cable does not exceed 165 feet from the wall dimmer to the last dimmer pack. For further information, refer to the instruction manual provided with the LC-1CH-DP. PRECAUTION LC-DMR Fixture Fixture 0-24VDC 0-24VDC Signal Out Dimmer Pack 24VDC LED Driver Signal Out Dimmer Pack 24VDC LED Driver All dimming components are rated for dry location only. They must be installed within an enclosure suitable for the environment. TokiLux Installation Instructions TM Page 5 24 VAC Magnetic Transformers TokiLux may also be operated from Tokistar 24 VAC magnetic transformers. Transformers should be installed in an accessible location. Magnetic transformers generate heat and must be installed in locations where there is free-air circulation. Refer to the manual provided with the transformer for detailed installation instructions. Dimming Although Tokistar Transformers are fully dimmable on the primary input with phase control/triac dimming systems, they may not show favorable results at all dim levels. Optimum dimming results are achieved with our 24 VDC Drivers and our pulse-width modulation (PWM) dimming devices installed on the secondary output of drivers. PRECAUTIONS Do Not Exceed 4 Amps Per Circuit. TOKISTAR® LIGHTING 1015 E. Discovery Lane Anaheim, CA 92801 TEL: 714 772 7005 FAX: 714 772 7014 email: info@tokistar.com Website: tokistar.com Version 1.3