General Description
Tokistar’s TokiLux WG Series may be operated at 24 VDC or 24 VAC. Light Bars are installed end-to-end
within the TokiLux track. Each Light Bar contains five LEDs and consumes a total of 4 watts. An individual
run length may contain up to 24 Light Bars. Each track is labeled with wattage and operating voltage.
Light Bar
TokiLux Track
Multiple Length Assembly
Any run length exceeding 12 Light Bars will be supplied as multiple lengths to be
joined. Channel with parallel louvers require Flex Connectors to join the lengths.
TokiLux Track
Light Bar
Retainer Clips
Maximum Run Length
Maximum 24 Light Bars
PRECAUTIONS
1. Read all instructions completely before beginning installation.
2. Turn off electricity before beginning installation.
3. All wiring is to be performed by a qualified electrician.
4. Installation must comply with the National Electrical Code, and all applicable codes.
5. Turn main supply to the LED Driver on only after all connections have been made and tested.
6. Use only LED Drivers provided by Tokistar with the system.
TOKISTAR® LIGHTING
1015 E. Discovery Lane
Anaheim, CA 92801
TEL: 714 772 7005 FAX: 714 772 7014
email: info@tokistar.com Website: tokistar.com
Version 1.2
TokiLux WG Installation Instructions
Page 2
TM
Connectors and Retainer Clips
Feed Connector
Flex Connector
Feed Connectors bring power to one end of a TokiLux WG run.
Up to 24 Light Bars can be powered from a single connector.
Flex Connectors turn corners and enable
smaller sections to conform to curves.
Part#:TLX-FLC-WG
Part#:TLX-CON-WG
A Retainer Clip is required
between the 4th and 5th
LED of the 1st Light Bar
Retainer Clips
Retainer clips are included with Feed
Connectors, Flex Connectors and fixtures
exceeding 12 Light Bars. These snap onto
the fixture to provide a secure connection.
Retainer Clip
Channel with parallel louvers
require Flex Connectors to
join the lengths..
Retainer Clips snap in
place from above.
End Cap
Mounting Clamp
End Caps insulate the end of
a run of TokiLux WG.
Mounting clamps are attached with
screws and the Tokilux WG fixture
is snapped in place. Recommended
spacing is every 12".
Part #: TLX-ED-WG
Part #: TLX-CP-WG
Mounting Clamp
TLXWG-CH Channels with Mounting Brackets
Fixtures are supplied with brackets attached.
Installation with Adjustable Mounting Bracket.
Open Adjustable Bracket, then
attach to ceiling with screws.
Rotate fixture to
vertical position.
Installation with Fixed Mounting Bracket.
Adjust fixture to precisely
focus light where needed.
TokiLux WG Installation Instructions
Page 3
TM
Secondary Circuit Wiring
Secondary Circuit Limit
Do Not Exceed 4 Amps
(96 watts @ 24 VDC or 24 VAC)
A maximum of 24 Light Bars can be powered
on one circuit from the power supply.
Recommended Lead Wire Size
The distance from the power supply to the fixture, and the load of
the fixture, will determine the proper size of secondary wire. Feed
Connectors are provided with a 6' lead. If additional wire needs to
be attached to the Feed Connector, refer to the recommendations
in this chart.
Additional Secondary Lead
Secondary Lead Wires
Wire Size
Wire Length
#16 AWG
50' (15 M)
#14 AWG
75' (23 M)
#12 AWG
100' (30 M)
#10 AWG
150' (46 M)
6' Factory Lead
Splice
LED Driver Installation
LDR24-4A
This 96 Watt Class 2 LED Driver converts an AC input into a 24 VDC output. Refer to the manual provided
with the LED Driver for detailed installation instructions.
Part#
LDR24-4A
Input Volts
100~277
Output Volts
24 VDC
Output Ratings
1 @ 4 Amps
LDR24-192
Tokistar’s Class 2 LDR24-192 has two independent 96 watt outputs. If the system is dimmed, each of the
outputs requires an independent dimmer pack. This unit has wiring compartments for splicing on input and
output leads, and can be connected directly to conduit. Refer to the manual provided with the LED Driver for
detailed installation instructions.
Part#
LDR24-192
Input Volts
100~277
Output Volts
24 VDC
Output Ratings
2 @ 4 Amps
TokiLux WG Installation Instructions
Page 4
TM
LC-1CH-MULTI Dimming System
Dimmer Pack - Part #: LC-1CH-MULTI
Each dimmer pack receives 24 VDC from an LED Driver.
The LDR24-192 LED Driver has two independent 96 watt
outputs. Each output requires an independent dimmer pack.
DMX Mode - Each unit is independently addressable.
Up to 36 dimmer packs may be connected in series. For
applications exceeding 36 dimmer packs, an additional feed
from the DMX dimmer is required. The additional feed(s)
can be sent directly from the dimmer, or you may use DMX
Splitters. Consult factory on details of DMX Splitters.
Analog Modes - For operation from devices using
0/1-10VDC protocol, up to 10 dimmer packs may be connected in series. For applications exceeding 10 dimmer
packs, an additional feed from the analog dimming device
is required.
Manual Mode - You may select a light intensity the fixtures
will operate at. In this case, no external dimming device is
required.
DMX Wiring Diagram
DMX Console
Fixture
0-24 VDC
0-24 VDC
Dimmer Pack
Dimmer Pack
For further information, refer to the instruction manual
provided with the LC-1CH-DP.
PRECAUTION
24 VDC
DMX Out
DMX In
LED Driver
DMX Out
Analog Dimmer
0/1-10 VDC Wiring Diagram
Fixture
Fixture
Analog Out
Analog Out
0-24 VDC
0-24 VDC
Dimmer Pack
24VDC
Dimmer Pack
24VDC
LED Driver
LED Driver
Dual output LED drivers require a
dimmer pack for each output.
LC Dimming System
Dimmer Pack - Part #: LC-1CH-DP
Each dimmer pack receives 24 VDC from an LED Driver.
A CAT5 cable is provided with each unit. Up to 25 dimmer
packs may be connected in series if the total length of all
CAT5 cable does not exceed 165 feet from the wall dimmer
to the last dimmer pack.
LED Driver
24 VDC
For further information, refer to the instruction manual
provided with the LC-1CH-MULTI.
Wall Dimmer - Part #: LC-DMR
Power to the remote wall dimmer is provided from the LED
Driver powering the first Dimmer Pack. A 50 foot CAT5
cable is provided.
Fixture
LC-DMR
Fixture
Fixture
0-24VDC
0-24VDC
Signal Out
Dimmer Pack
24VDC
LED Driver
Signal Out
Dimmer Pack
24VDC
LED Driver
All dimming components are rated for dry location only. They must be installed within an enclosure
suitable for the environment.
TokiLux WG Installation Instructions
TM
Page 5
24 VAC Magnetic Transformers
TokiLux WG may also be operated from Tokistar 24 VAC magnetic transformers. Transformers should be installed
in an accessible location. Magnetic transformers generate heat and must be installed in locations where there is
free-air circulation. Refer to the manual provided with the transformer for detailed installation instructions.
Dimming
Although Tokistar Transformers are fully dimmable on the primary input with phase control/triac dimming systems,
they may not show favorable results at all dim levels. Optimum dimming results are achieved with our 24 VDC Drivers
and our pulse-width modulation (PWM) dimming devices installed on the secondary output of drivers.
PRECAUTIONS
Do Not Exceed 4 Amps Per Circuit.