Compact Fire Pump Systems At the heart of our systems you’ll find the Aurora pumps you’ve relied on for over 80 years. Aurora offers a complete system that has a small footprint and is ideal for buildings with limited space. This built to order and pre-engineered system is factory assembled and tested. Ready to set: only unit base grouting, pipe and power connections need to be completed on site. SYSTEM INCLUDES n UL listed/FM approved Aurora fire pump n Casing pressure relief valve n UL listed/FM approved fire pump controller n Hose header with valves, caps & chains n Aurora jockey pump n Suction and discharge piping per NFPA 20 n UL listed jockey pump controller n All electrical components pre-wired at factory n Pressure sensing lines complete per NFPA 20 n Complete system hydrostatically tested n Listed OS & Y gate & butterfly valves n All components are factory choice n Suction and discharge pressure gauges SYSTEM FEATURES n Fits through a 36” doorway n Capacities of 50-750 GPM n ETL Listed System n Pressures of 40-160 PSI n Built to NFPA-20, NFPA-70 and NEC Standards AVAILABLE OPTIONS n Automatic Air Release Valve n Transfer Switch OPTIONAL GPM 50 PSI 75 - 155 MODEL 2-383-9C HP 10 - 25 100 43 - 70 3-383-7A 7.5 - 15 70 - 150 2-383-9C 10 - 25 41 - 60 3-383-7A 7.5 - 10 60 - 160 3-383-9A 15 - 50 40 - 55 3-383-7A 7.5 - 15 56 - 159 3-383-9A 15 - 50 40 - 65 3-383-7B 15 - 20 70 - 138 3-383-9 20 - 50 42 - 73 4-383-7B 15 - 30 74 - 90 4-383-9B 25 - 30 91 - 139 4-383-9 30 - 60 51 - 71 4-383-7B 20 - 30 70 - 85 4-383-9B 25 - 30 85 - 136 4-383-9 30 - 60 49 - 72 4-383-7B 20 - 30 82 - 135 4-383-9 30 - 60 96 - 131 4-383-9B 40 - 60 55 - 71 4-383-7B 25 - 30 72 - 92 4-383-9C 30 - 50 94 - 130 4-383-9B 40 - 60 54 - 84 4-383-13 40 - 75 86 - 143 4-383-10B 60 - 100 150 200 250 300 400 450 500 750 HB 66 (1676) 64 (1626) 66 (1676) 64 (1626) 72 (1829) 64 (1626) 72 (1829) 72 (1829) 72 (1829) 72 (1829) 72 (1829) 72 (1829) 72 (1829) 72 (1829) 72 (1829) 84 (2134) 72 (1829) 72 (1829) 84 (2134) 72 (1829) 72 (1829) 84 (2134) 84 (2134) HF 64 (1626) 62 (1575) 64 (1626) 62 (1575) 70 (1778) 62 (1575) 70 (1778) 70 (1778) 70 (1778) 70 (1778) 70 (1778) 70 (1778) 70 (1778) 70 (1778) 70 (1778) 82 (2083) 70 (1778) 70 (1778) 82 (2083) 70 (1778) 70 (1778) 82 (2083) 82 (2083) HD 13.25 (337) 14.25 (362) 13.25 (337) 14.25 (362) 14.25 (362) 14.25 (362) 14.25 (362) 14.25 (362) 13.88 (353) 15.25 (387) 15.00 (381) 15.00 (381) 15.25 (387) 15.00 (381) 15.00 (381) 15.25 (387) 15.00 (381) 15.00 (381) 15.25 (387) 15.00 (381) 15.00 (381) 17.81 (452) 17.06 (433) HS 13.25 (337) 14.25 (362) 13.25 (337) 14.25 (362) 14.25 (362) 14.25 (362) 14.25 (362) 13.75 (349) 13.88 (353) 15.25 (387) 15.00 (381) 15.00 (381) 15.25 (387) 15.00 (381) 15.00 (381) 14.75 (375) 15.00 (381) 15.00 (381) 14.75 (375) 15.00 (381) 15.00 (381) 17.81 (452) 17.06 (433) W 28.25 (718) 28.25 (718) 28.25 (718) 28.25 (718) 28.75 (730) 28.25 (718) 28.75 (730) 28.25 (718) 28.75 (730) 29.25 (743) 29.25 (743) 29.25 (743) 29.25 (743) 29.25 (743) 29.25 (743) 29.25 (743) 29.25 (743) 29.25 (743) 29.25 (743) 29.50 (749) 29.25 (743) 32.50 (826) 30.50 (775) CP 65.75 (1670) 67.25 (1708) 65.75 (1670) 67.25 (1708) 70.25 (1784) 67.25 (1708) 70.25 (1784) 75.50 (1918) 71.25 (1810) 73.50 (1867) 74.50 (1892) 74.50 (1892) 73.50 (1867) 74.50 (1892) 74.50 (1892) 89.25 (2267) 81.00 (2057) 81.00 (2057) 89.25 (2267) 81.00 (2057) 81.00 (2057) 93.50 (2375) 89.50 (2273) NOTES: 1. All dimensions are in inches(mm) and may vary ±3/8” (10). 2. Not for construction purposes, unless certified. 3. System suction and discharge flanges are ANSI class 125 flat face. 4. Refer to selection tables in section 911 for selection of pump sizes and motor horsepower for specific applications. 5. Standard controller is across-the-line. Refer to factory for the availability of optional controller starting methods. 6. Dimensions and specifications subject to change without notice. FIRE PUMP SPEC JOCKEY PUMP CONTROLLER FIRE PUMP A Metron model_________ UL listed, jockey pump controller The pump shall be an Aurora model 383 vertical in-line centrifugal shall be supplied. The jockey pump controller shall come complete pump. The pump shall be rated for ________GPM @ _______PSI. with a fusible disconnect, prepiped pressure switch, front mounted The pump shall be listed by the Underwriters' Laboratory and/or be hand-off-auto selector switch and overload relays. The controller approved by Factory Mutual. The pump shall have a bronze impeller, enclosure shall be of Nema 2 type. bronze case wear ring, packing gland and shaft sleeve. The pump shall deliver no less than 65% of rated pressure at 150% of rated flow. ACCESSORIES Systems shall include: The shut-off pressure shall not exceed 140% of rated pressure. • Suction and discharge pressure gauges on fire pump. ELECTRIC DRIVER • Isolating gate valve at suction for both fire pump and jockey pump. The motor shall be listed by Underwriters' Laboratories and have a • Isolation valve at discharge for both fire pump and jockey pump. maximum of ___horsepower, 3-phase, ______hertz, ______volts. • Discharge check valve for fire pump and jockey pump. It shall be open drip proof with a 1.15 service factor and shall comply with the provisions of N.F.P.A 70, National Electric Code as FACTORY PREFABRICATION AND TESTING described in N.F.P.A 20. All of the above equipment (except the test header and hose valves) shall be mounted on a common base. All pipes, piping components, CONTROLLER and the pressure sensing lines shall be firmly anchored to the steel The motor controller shall be a Metron model _____, listed by base by means of structural steel supports. All electrical wiring Underwriters Laboratories and approved by Factory Mutual for fire between controllers and motors shall be completed and tested at the pump service. It shall be compatible with the motor horsepower and factory. The entire packaged system will be hydrostatically tested at voltage. It shall be of the full voltage type with a withstand rating of the factory prior to shipment. Additionally, all equipment will be tested ________42 AIC RMS symmetrical. The controller enclosure shall in accordance with the requirements of NFPA 20, U.L. and F.M. be of Nema 2 type. The controller shall be completely assembled, wired and tested prior to shipment. NOTE: Aurora Pump reserves the right to make revisions to its products and their specifications, and to this bulletin and related information, without notice. — Your Authorized Local Distributor — AURORA PUMPS ARE R LISTED FM APPROVED MARKETING & SALES: 800 AIRPORT ROAD • NORTH AURORA, ILLINOIS U.S.A. • 60542 PHONE: (630) 859-7000 U.S.A./CANADA FAX: (630) 859-7060 WORLDWIDE FAX: (630) 859-1226 AURORA MFG. PLANT: 800 AIRPORT ROAD • NORTH AURORA, ILLINOIS U.S.A. • 60542 SALES OFFICES IN ALL MAJOR CITIES AND COUNTRIES Refer to “Pumps” in yellow pages of your phone directory for your local Distributor PRINTED IN U.S.A. JOCKEY PUMP The jockey pump shall be an Aurora model________, size_______. The pump shall be rated for_______GPM @ _________PSI. The jockey pump will be close coupled to a ODP motor. The motor will operate at ________HP, ______RPM,________v, _______Hertz. AP-CFPS 10/06 The contractor shall provide and install an Aurora model 383 packaged fire pump system designed in accordance with NFPA 20. The system shall be rated for a flow of ________GPM @ ______PSIG. The system shall be mounted on a common base plate and include all necessary components such that the customer only needs to run piping to and from the system and connect incoming power. The packaged fire pump system shall include the following equipment: