Falk Quadrive Model A, Sizes 5407-5608 Shaft Mounted

advertisement
Falk™ Quadrive® Shaft Mtd. Drives Model A • Non-Std. Mounting Installation
Sizes 5407-5608
(Page 1 of 2)
Modifications For Non-Standard Mounting Positions
Instructions
For non-standard mountings, modify drives as illustrated
below and on Page 2 to assure satisfactory lubrication. For
applications that exceed the limits shown, drives that are both
rotated AND tilted and for with backstops, consult Factory.
CAUTION: Inadequate lubrication will cause damage.
When replacing a pipe plug (P) with a street elbow (E), insert
the plug in the elbow (E/P). When replacing a pipe plug (P)
with a street elbow (E), pipe nipple (N) and a pipe cap (C),
discard the pipe plug. Kits consist of parts for an oil expansion
chamber. Pipe fittings and kits tabulated on Page 2 are
available from Rexnord. Pipe fittings may also be purchased
locally. Use galvanized pipe fittings.
Remove all pipe plugs and coat them and the added parts,
with Permatex #3 or equivalent to prevent leakage. Install
parts as illustrated to suit the mounting position. The air vent
must be in the top of the drive or in the kit standpipe. Fill
drives with oil to the level indicated by the letter “L” in the
following drawings.
Standard Drive Mounting Limits
The 10° Max rotation illustrated at the left
applies to standard 3, 6, 9 & 12 o’clock
mountings. For higher limits, follow the
instructions at left and the drawings below. (6
o’clock illustrated)
ROTATION
CCW
±10° MAX.
CW
Horizontal Drive Modifications for 10 to 20° Drive Rotation
CODE
B — Reducing Bushing
C — Cap
E — Street Elbow
L — Oil Level
10 to 20° Clockwise Rotation
10 to 20° Counterclockwise
3 O’Clock — CW Rotation
3 O’Clock — CCW Rotation
L
5407 = KIT 0786777
5415 THRU 5608 = KIT 0786778
N — Nipple
P — Pipe Plug
STD — No
Modifications
5407 = .750 E/C & .750 x 3.00 N
5415 = 1.250 E/C & 1.250 x 3.00 N
5507 = 1.250 E/C & 1.250 x 3.50 N
5608 = 1.250 E/C & 1.250 x 2.50 N
L
6 O’Clock — CW Rotation
6 O’Clock — CCW Rotation
L
L
5407 = .750 E/C & .750 x 1.375 N
5415 & 5507 = 1.250 E/C & 1.250 x 1.625 N
5608 = 1.25 E/P
9 O’Clock — CW Rotation
5407, 5415, 5507, & 5608 = STD
9 O’Clock — CCW Rotation
5407 = .750 E/C & .750 x 1.375 N
5415 & 5507 = 1.250 E/P
5608 = STD
L
5407 = KIT 0786777
5415 THRU 5608 = KIT 0786778
This oil level applies when
only a street elbow with a
pipe plug is used.
12 O’Clock — CCW Rotation
12 O’Clock — CW Rotation
L
L
5407 = .750 E/C & .750 x 1.375 N
5415 & 5507 = 1.25 E/C & 1.25 x 1.625 N
5608 = 1.25 E/P
L
L
5407, 5415 & 5507 = STD
5608 = KIT 0786778
5608
Rexnord Industries, LLC, Geared Products
3001 W. Canal St., Milwaukee, WI 53208-4200 USA Telephone: 414-342-3131
Fax: 414-937-4359 e-mail: info@rexnord.com web: www.rexnord.com
378-125
June 2006
Supersedes 4-92
Non-Std. Mounting Installation • Falk™ Quadrive Shaft Mtd. Drives Model A
(Page 2 of 2)
Sizes 5407-5608
Modifications For Non-Standard Mounting Positions
Standard Drive
Mounting Limits
INCLINE
20° UP
MAX.
5° DOWN
MAX.
4407 & 4415 = 0° INCLINE
DOWN ON DRIVES WITH
BACKSTOPS IN 9 OR 12 O’CLOCK
MOUNTING POSITION.
4507 & 4608 = 5° INCLINE ON
DRIVES WITH BACKSTOPS IN ALL
MOUNTING POSITIONS.
Standard Pipe Fittings
The limits illustrated at the left apply to
standard 3, 6, 9 & 12 o’clock
mountings. For higher limits, follow the
instructions on Page 1 and the drawings
below. (6 o’clock illustrated)
CODE
.750-14 NPT
H
Falk No.
.750 Street Elbow
.750 Cap
.750 x 1.375 Nipple
.750 x 3 Nipple
.750 x .500 Bushing
0915253
0914804
0915824
0915836
0914652
— Inches
1.25-11.5 NPT
1.25 Street Elbow
1.25 Cap
1.25 x 1.625 Nipple
1.25 x 2.5 Nipple
1.25 x 3 Nipple
1.25 x 3.5 Nipple
1.25 x .500 Bushing
Falk No.
0915255
0914806
0915882
0915885
0915886
0915897
0914656
H Kits: Falk Nos. 738471 . . . . Oil expansion chamber parts.
C — Cap
N — Nipple
E — Street Elbow P — Pipe Plug
L — Oil Level
STD — No
Modifications
All pipe fittings are galvanized.
Horizontal Drive Modifications for Inclined H.S. Shaft
H.S. Shaft Inclined 20 to 30° Up
H.S. Shaft Inclined 5 to 30° Down
3 O’Clock H.S.S. Up
3 O’Clock H.S.S. Down
FAR
SIDE
L 5407 = .750 E/P
5415 & 5507 = 1.25 E/P
5608 = STD
FAR
SIDE
5407 THRU 5608 = STD
L
6 O’Clock H.S.S. Down
6 O’Clock H.S.S. Up
5407, 5415 & 5507 = STD
5608 = 5 - 20º STD
5608 = 21 - 30º 1.250 E/P
5407 = .750 E/P
L 5415 & 5507 = 1.25 E/P
L
5608 = STD
9 O’Clock H.S.S. Up
9 O’Clock H.S.S. Down
L
5407 = KIT 0786777
5415, 5507 & 5608 = KIT 0786778
12 O’Clock H.S.S. Up
5407 = .750 E/C, .750 x 1.375 N, KIT 0786777
5415 & 5507 = 1.25 E/C & 1.25 x 2.50 N
5608 = 5 - 20º STD
5608 = 21 - 30º 1.250 E/P, KIT 0786778
L
12 O’Clock H.S.S. Down
L
5407 = .750 E/P, KIT 0786777
5415 & 5507 = 1.25 E/P
5608 = STD
FAR
SIDE
L
5407 = .750 E/P, KIT 0786777
5415 & 5507 = KIT 0786778
5608 = KIT 0786778
FAR
SIDE
NOTE: FOR SIZES 5507 & 5608 WITH BACKSTOP, MAXIMUM INCLINE IS 5º (ALL CLOCK POSITIONS).
378-125
June 2006
Supersedes 4-92
Rexnord Industries, LLC, Geared Products
3001 W. Canal St., Milwaukee, WI 53208-4200 USA Telephone: 414-342-3131
Fax: 414-937-4359 e-mail: info@rexnord.com web: www.rexnord.com