Falk™ Quadrive® Shaft Mtd. Drives Model A • Non-Std. Mounting Installation Sizes 5407-5608 (Page 1 of 2) Modifications For Non-Standard Mounting Positions Instructions For non-standard mountings, modify drives as illustrated below and on Page 2 to assure satisfactory lubrication. For applications that exceed the limits shown, drives that are both rotated AND tilted and for with backstops, consult Factory. CAUTION: Inadequate lubrication will cause damage. When replacing a pipe plug (P) with a street elbow (E), insert the plug in the elbow (E/P). When replacing a pipe plug (P) with a street elbow (E), pipe nipple (N) and a pipe cap (C), discard the pipe plug. Kits consist of parts for an oil expansion chamber. Pipe fittings and kits tabulated on Page 2 are available from Rexnord. Pipe fittings may also be purchased locally. Use galvanized pipe fittings. Remove all pipe plugs and coat them and the added parts, with Permatex #3 or equivalent to prevent leakage. Install parts as illustrated to suit the mounting position. The air vent must be in the top of the drive or in the kit standpipe. Fill drives with oil to the level indicated by the letter “L” in the following drawings. Standard Drive Mounting Limits The 10° Max rotation illustrated at the left applies to standard 3, 6, 9 & 12 o’clock mountings. For higher limits, follow the instructions at left and the drawings below. (6 o’clock illustrated) ROTATION CCW ±10° MAX. CW Horizontal Drive Modifications for 10 to 20° Drive Rotation CODE B — Reducing Bushing C — Cap E — Street Elbow L — Oil Level 10 to 20° Clockwise Rotation 10 to 20° Counterclockwise 3 O’Clock — CW Rotation 3 O’Clock — CCW Rotation L 5407 = KIT 0786777 5415 THRU 5608 = KIT 0786778 N — Nipple P — Pipe Plug STD — No Modifications 5407 = .750 E/C & .750 x 3.00 N 5415 = 1.250 E/C & 1.250 x 3.00 N 5507 = 1.250 E/C & 1.250 x 3.50 N 5608 = 1.250 E/C & 1.250 x 2.50 N L 6 O’Clock — CW Rotation 6 O’Clock — CCW Rotation L L 5407 = .750 E/C & .750 x 1.375 N 5415 & 5507 = 1.250 E/C & 1.250 x 1.625 N 5608 = 1.25 E/P 9 O’Clock — CW Rotation 5407, 5415, 5507, & 5608 = STD 9 O’Clock — CCW Rotation 5407 = .750 E/C & .750 x 1.375 N 5415 & 5507 = 1.250 E/P 5608 = STD L 5407 = KIT 0786777 5415 THRU 5608 = KIT 0786778 This oil level applies when only a street elbow with a pipe plug is used. 12 O’Clock — CCW Rotation 12 O’Clock — CW Rotation L L 5407 = .750 E/C & .750 x 1.375 N 5415 & 5507 = 1.25 E/C & 1.25 x 1.625 N 5608 = 1.25 E/P L L 5407, 5415 & 5507 = STD 5608 = KIT 0786778 5608 Rexnord Industries, LLC, Geared Products 3001 W. Canal St., Milwaukee, WI 53208-4200 USA Telephone: 414-342-3131 Fax: 414-937-4359 e-mail: info@rexnord.com web: www.rexnord.com 378-125 June 2006 Supersedes 4-92 Non-Std. Mounting Installation • Falk™ Quadrive Shaft Mtd. Drives Model A (Page 2 of 2) Sizes 5407-5608 Modifications For Non-Standard Mounting Positions Standard Drive Mounting Limits INCLINE 20° UP MAX. 5° DOWN MAX. 4407 & 4415 = 0° INCLINE DOWN ON DRIVES WITH BACKSTOPS IN 9 OR 12 O’CLOCK MOUNTING POSITION. 4507 & 4608 = 5° INCLINE ON DRIVES WITH BACKSTOPS IN ALL MOUNTING POSITIONS. Standard Pipe Fittings The limits illustrated at the left apply to standard 3, 6, 9 & 12 o’clock mountings. For higher limits, follow the instructions on Page 1 and the drawings below. (6 o’clock illustrated) CODE .750-14 NPT H Falk No. .750 Street Elbow .750 Cap .750 x 1.375 Nipple .750 x 3 Nipple .750 x .500 Bushing 0915253 0914804 0915824 0915836 0914652 — Inches 1.25-11.5 NPT 1.25 Street Elbow 1.25 Cap 1.25 x 1.625 Nipple 1.25 x 2.5 Nipple 1.25 x 3 Nipple 1.25 x 3.5 Nipple 1.25 x .500 Bushing Falk No. 0915255 0914806 0915882 0915885 0915886 0915897 0914656 H Kits: Falk Nos. 738471 . . . . Oil expansion chamber parts. C — Cap N — Nipple E — Street Elbow P — Pipe Plug L — Oil Level STD — No Modifications All pipe fittings are galvanized. Horizontal Drive Modifications for Inclined H.S. Shaft H.S. Shaft Inclined 20 to 30° Up H.S. Shaft Inclined 5 to 30° Down 3 O’Clock H.S.S. Up 3 O’Clock H.S.S. Down FAR SIDE L 5407 = .750 E/P 5415 & 5507 = 1.25 E/P 5608 = STD FAR SIDE 5407 THRU 5608 = STD L 6 O’Clock H.S.S. Down 6 O’Clock H.S.S. Up 5407, 5415 & 5507 = STD 5608 = 5 - 20º STD 5608 = 21 - 30º 1.250 E/P 5407 = .750 E/P L 5415 & 5507 = 1.25 E/P L 5608 = STD 9 O’Clock H.S.S. Up 9 O’Clock H.S.S. Down L 5407 = KIT 0786777 5415, 5507 & 5608 = KIT 0786778 12 O’Clock H.S.S. Up 5407 = .750 E/C, .750 x 1.375 N, KIT 0786777 5415 & 5507 = 1.25 E/C & 1.25 x 2.50 N 5608 = 5 - 20º STD 5608 = 21 - 30º 1.250 E/P, KIT 0786778 L 12 O’Clock H.S.S. Down L 5407 = .750 E/P, KIT 0786777 5415 & 5507 = 1.25 E/P 5608 = STD FAR SIDE L 5407 = .750 E/P, KIT 0786777 5415 & 5507 = KIT 0786778 5608 = KIT 0786778 FAR SIDE NOTE: FOR SIZES 5507 & 5608 WITH BACKSTOP, MAXIMUM INCLINE IS 5º (ALL CLOCK POSITIONS). 378-125 June 2006 Supersedes 4-92 Rexnord Industries, LLC, Geared Products 3001 W. Canal St., Milwaukee, WI 53208-4200 USA Telephone: 414-342-3131 Fax: 414-937-4359 e-mail: info@rexnord.com web: www.rexnord.com