May 2014
High
Session / App
Virtualization
Virtual desktops
(VDI)
App / Desktop virtualization with graphics acceleration
Density
Performance – Cost/Seat
Knowledge workers
Productivity workers
Task workers
Power users
Workstation-class workers
2 © Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. HP Confidential. For Training Purposes Only.
High
Client
Devices
Different solutions for different user types & use-cases
Task Workers
(Traditional VDI)
Workload attributes and Solutions
•
Data entry, very few apps, primarily text based
•
Light VM (Virtual Machine) instances – Shared servers for
10s to 1000s of users
•
Often Non-Persistent Images requiring NO graphics and compute performance to deliver desktops
VDI-in-a-Box
DL380p
Productivity Workers &
Knowledge Workers
Current Solutions Gap
Mid Power Users
C7000
Blade Servers
DL380
Rack Servers
High End Graphical Power
Users
Workload attributes and Solutions
•
Full desktop w/ accelerated graphics, highperformance compute required
•
Blade workstation or SL servers with
• graphics accelerators
3 © Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
SL250s/270s w/ NVIDIA
GPUs
WS460c Gen8 w/
NVIDIA GPUs
© Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
5
Server Motherboard
ECC Memory ECC Memory
SoC-based Server Motherboard
ECC Memory
SoC
6
Processor Processor
Processor SoC Features
Mgmt
Interface
NIC(s)
Storage
Ctrlr
Southbridge
Storage
Ctrlr
Mgmt Production
Network
Storage
Management
Logic
Video NIC(s) •
Less general purpose, more workload focused
•
Dramatic reduction in power, cost, and space
•
Multiple SoC partners bring unique solutions
(e.g. GPU cores, DSP cores)
Mgmt
Network
VGA
Console
Production
Network
HDDs
© Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
ProLiant
Moonshot
Server
ProLiant m300
Server
ProLiant m700
Server
© Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
ISV reference architectures
Static Web Serving
Hosting
ProLiant Moonshot Server
Dynamic Web Serving
Hosting
ProLiant m300
Hosted Desktop
Infrastructure
ProLiant m700
8 © Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
The essential foundation for the new style of IT
45 hot-plug cartridges
• Single-server = 45 servers per chassis
•
Quad-server =180 servers per chassis
Dual low-latency
• switches
Module (45 x1Gb downlinks)
•
HP Moonshot -180G Switch
Module (180x1Gb downlinks)
Compute, Storage, or Combination x86 , ARM, or Accelerator
9 © Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
Delivering on the promise of extreme low energy computing
Dual Network Uplinks
• HP Moonshot-6SFP Uplink
Module (6 x10Gb Stackable
Uplinks)
• HP Moonshot-4QSFP+ Uplink
Module (4x40Gb Stackable
Uplinks
5 serviceable, redundant, hot-plug fan modules
HP Common-Slot Power
Supplies
Rear View
HP Moonshot 1500 Single
Federated Chassis
Management module
10 © Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
Supporting a range of current and future capabilities
$
Traffic isolation and stacking for resiliency with dual low-latency switches
Economical and flexible storage with shared storage lanes
Multiple servers managed as one platform with dedicated iLO network
Integrated cluster fabric with point-to-point connectivity
11 © Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
8 Lanes
Traffic isolation and stacking for resiliency with dual low-latency switches
Single servers
45 ports
Uplink Module A
Quad servers
180 ports
Switch A
Uplink Module A
Switch A
Servers 1-45
Switch B
Uplink module B
12 © Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
Switch B
Uplink module B
Servers 1-45
45x 1 GbE Downlinks
6x SFP+ Uplinks
•
•
•
•
•
•
•
•
•
Shipping Now
Moonshot-45G Switch Module
Moonshot-6SFP Uplink Module
Oversubscription: None
Packet buffer: 9MB
Layer 2, Layer 3, Routing, QoS,
Stacking, Management (CLI,
SNMP, sFlow)
510ns latency*
50 Watts, max
No license keys
Compatible with ProLiant Moonshot Server & ProLiant m300
180x 1 GbE Downlinks
4x QSFP+ Uplinks
•
•
•
•
•
•
•
•
•
Shipping Now
Moonshot-180G Switch Module
Moonshot-4QSFP+ Uplink Module
Oversubscription: 1.1 : 1
Packet buffer: 2*11MB
Layer 2, Layer 3, Routing, QoS,
Stacking, Management (CLI,
SNMP, sFlow)
317ns latency*
210 Watts, max
No license keys
Compatible with ProLiant m700
* Single port uplink latency with 64-byte packets
13 © Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
•
•
•
•
•
•
•
•
Two high-density, low-power switch modules
Low-latency switching performance
810 x 1GbE ports per rack or 3240 x 1GbE ports per rack
108 x 10GbE uplink ports per rack or 72 x 40GbE uplink ports per rack
Dual switches provide traffic isolation or can be stacked for resiliency
Rack level stacking to simplify management domain
Designed for automated configuration and management , chassis manager integration
Layer 2, Layer 3 Routing & QoS, Management (CLI, SNMP, SFLOW). No license keys
14 © Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
Economical and flexible storage with shared storage lanes
$
Various cartridge types for different combination
Compute Storage
Compute +
Storage
Creates multiple
“core to storage” for different solutions
Local Storage
Local HDD or flash storage
Low Cost Boot & Logging Distributed Storage or RAID
8-way drive slicing Storage expansion
Drive slicing reduces the cost of a boot drive 87%
15 © Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
Multiple servers managed as one platform with dedicated iLO network
SC
Switching
Fabric
SC
Management
Port
SC
Mgmt.
Hub
HP Moonshot
1500 Chassis
Management module
SC
Cooling
Sub-system
SC
SC
Storage
Backup or cartridge
SC
Power
Sub-system
SC: Satellite Controller
•
HP Moonshot 1500 Chassis Management module aggregates all to a common set of management interfaces
•
Single Ethernet port gateway
•
IPMI and Serial Console for each server
•
True out-of-band firmware update services
•
SL-APM Rack Management spans rack or multiple racks
16 © Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
Integrated cluster fabric with point-to-point connectivity
•
High-speed communication lanes between servers
•
Ring fabric allows minimum and direct card to card communication path
•
Suitable for applications where efficient localized traffic is beneficial
16 x 10.3 GBaud Lanes
4 x 10 GBaud Lanes
Cartridges
Ring fabric is SoC vendor specific, homogeneous and stays inside the chassis
17 © Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
© Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
HP Converged System M700
CPU
MEMORY
NETWORK
STORAGE
BOOT
BIOS
MGMT
POWER
OS
HP CS M700 (Glenn-4)
(4) 15W soldered down AMD Kyoto / 4 core / 1.5GHz with Integrated GPU
(Radeon 8000), SATA and SD controllers
(4) 8GB DDR3 SO-DIMM ECC 1600MHZ
(2) 1GbE NIC’s per nodes (BCM5720 on the cartridge)
1 128 GB iSSD (32GB/node) from drive directly, supports PXE boot for testing and deployment, iSSD Mezz
Option
HP BIOS – shared image
(1) Satellite Controller w/ Interface to CM iLO
Cartridge: 90W Peak, <50W Typical
Windows 7 / 64bit
19 © Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
PC for every user removes limits
Each user gets an
Bare-metal means
No I/O bottlenecks with
per user
20 © Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
1260 Desktops in the rack – Simple solution for knowledge worker
Provisioning Servers
(not included)
(2) HP ProLiant DL385 Gen8
8x300GB SAS 1.2TB+
2x10Gb
HP Moonshot System
Up to 7 Chassis with 45 m700
(180 nodes)
Each node:
Win7, apps, data streamed
Delivered via PVS
Protocol to end device
Microsoft RDP
Citrix HDX 3D Pro
Dual
40Gb
4x10Gb
Two HPN 5900
TOR Switches
(48XG-4QSFP
(not included)
2x10Gb
21 © Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
Storage (User data)
HP StoreEasy
12TB – 1PB+
SAS/SATASFF/LFF
HPN 5800
Leaf Switches
Non-Persistent
Desktops
“Blueprint” for Citrix non-persistent
CS100 chassis
•
Each node:
•
Win7, apps, data streamed
•
Delivered via PVS
•
Protocol to end device
•
Microsoft RDP
•
Citrix HDX
Rack
Provisioning
Servers
2x10G b
Storage
(user data)
Switche s
2x40G b
Switches
•
2 for Redundancy
•
Optional if choose to connect directly to core switch
Chassis (Stacked)
22 © Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
Provisioning Servers
•
2 for redundancy
•
MS Windows Server
2012 w/ Hyper-V
•
Citrix components:
•
Citrix Broker
(DDC)
•
Citrix PVS
Storage (User data)
•
User data store
•
Roaming profile
•
User Virt support
HP Moonshot iLO Chassis Management firmware CLI
Management for the cartridges and the chassis is performed through the HP Moonshot iLO CM firmware
CLI. This interface is accessed by administrators in the following ways:
Locally, using a serial cable
Remotely, using SSH
For easy access, this interface should be defined in DNS with a static IP address.
PowerShell scripts can also be used when deploying cartridge configurations.
For more information, see the HP Moonshot iLO Chassis Management CLI User Guide on the HP
Moonshot System website ( http://www.hp.com/go/moonshot/docs ).
HP Moonshot switch CLI
23
The HP Moonshot switch CLI can be accessed in the following ways:
Locally using a serial console cable
Remotely using SSH
Remotely using the iLO CM firmware VSP feature
For sample network configuration and maintenance scripts, see "HP Moonshot system HDI sample scripts
(on page 57 )."
Moonshot switches support SNMP and sFLOW for management and configuration. For more information, see the switch documentation in the HP Moonshot Information Library
( http://www.hp.com/go/moonshot/docs ).
© Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
Browsing: www.hp.com (HP’s web gateway)
Downloads: ftp.hp.com (driver updates )
6 Moonshot chassis
< 6kW Power total
< 1 Rack/data center
300M hits per day
100% www.hp.com
100% ftp.hp.com
24 © Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
89%
Less space
6
Cache
16
HTTP
Apache
16
Download files
94% (1)
Less power
New: Purdue and Singapore
Investigate, test, and benchmark applications in a secure and confidential environment
Houston,
Texas
Purdue University
Indiana
Grenoble,
France
Watch Discovery Lab video http://www.youtube.com/watch?v=ZuO-zcmjvgw
25
Email Discovery Lab ( hpdiscovery.lab@hp.com
) to find out more
© Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
Singapore
© Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
Workstation Server blade
Optional Graphics Expansion
Capture, compress and encrypt 3D graphics
Client
Decompress and
Display
Apply keyboard and mouse events
LAN or WAN
Remote Protocol
Capture Keyboard and mouse events
27 © Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
VMware
(vSGA)
Microsoft 2012 for RemoteFX
OpenGL 2.x
OpenGL 2.x
DirectX 9 DirectX 9, 10, 11
28 © Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
HP MultiGPU Carrier
NVIDIA GRID K1 & K2
NVIDIA Quadro 6000
NVIDIA Quadro K5000
Limitations of OpenGL, DirectX and
GPU memory you can assign to a VM
29 © Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
VMware
(vDGA)
OpenGL
2.x, 3.x, 4.x
DirectX
9, 10, 11
Citrix GPU
Pass-Through
OpenGL
2.x, 3.x, 4.x
DirectX
9, 10, 11
HP MultiGPU Carrier
NVIDIA GRID K1 & K2
NVIDIA Quadro K6000
NVIDIA Quadro K5000
NVIDIA Quadro K4000
NVDIA GRID with
Citrix XenServer
HP MultiGPU Carrier
True Virtual GPU
OpenGL 2.x, 3.x, 4.x
DirectX 9, 10, 11
NVIDIA GRID K1 & K2
NVIDIA Quadro K6000
NVIDIA Quadro K5000
No limitations of OpenGL and DirectX
30 © Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.
XenApp /
XenDesktop
OpenGL
DirectX
NVIDIA Quadro K6000
NVIDIA Quadro K5000
NVIDIA Quadro K4000
HP MultiGPU Carrier
NVIDIA GRID K1 & K2
31 © Copyright 2013 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice.