GNT400 Logic Signals Application Note

advertisement
GNT400 Series Logic Signals Theory of Operation
Below is a description of the J3 connector logic signals for the GNT400 Series power supplies. The part of the schematic from which
the signals are derived is pasted in below.
•
PS Off & Inhibit: Pins 1 & 2 are the control signals for PS Off and Inhibit. They both perform the same function in turning off
the output voltage, but they give you a choice of using either a high or a low input signal. Both are inactive during normal
operation. R62 pulls up the Inhibit signal internally to 5 V. R68 pulls PS Off down to Return. Then, as the waveforms show,
changing the state of either signal will turn off the output voltage.
•
The DC OK signal (pin 4) goes high (5 V) when output voltage exceeds 92% of nominal voltage.
•
The PWR OK signal (pin 3) monitors the ac input voltage and goes high 100-200 ms after DC OK goes high. It will then go
low when it senses impending loss of sufficient ac power and will do so at least 4 ms before output voltage drops out of
spec. This is meant to provide enough warning time to allow your logic system to perform any housekeeping needed right
before power is lost.
•
5V standby (pin 6) is a voltage that is always on, even during inhibit. It can be used to power one of the control signals or
power some logic during a sleep mode. The max current rating is 100 mA.
•
Remote Sense: (pins 7 & 8) These terminals can either be ignored which leaves the output voltage point of regulation to be
at the output terminals, or can be strategically connected to the user’s load to create a new point of regulation. Use of these
pins is recommended only if very tight regulation is required at the load.
SL Power Electronics Corp., 6050 Kings Drive, Bldg A, Ventura, CA 93003, USA. Phone: (805) 486-4565 Fax: (805) 487-8911 www.slpower.com.
AN-137 Rev 1, 9/15/08.
Data Sheet © 2008 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication.
However, SL Power accepts no reposnsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.