DE5_P17-24.fm Page 23 Wednesday, January 7, 2009 5:13 PM Panelboards ® I-Line - Circuit Breaker Type – Ready to Install (RTI) Accessories Terminal Data Standard Mechanical Lugs—Main Lugs Panel Type Ampere Rating I-LINE Wire Range Wire Bending Space per CSA Lug Wire Rangeb 100 ... ... 225 (1) #6–300 kcmil Al/Cu (1) #6–300 kcmil Al/Cu 400 (2) #2–600 kcmil Al/Cu (1) #2–600 kcmil Al/Cu (2) #2–500 kcmil Al/Cu 600 (2) #2–600 kcmil Al/Cu (2) #2–500 kcmil Al/Cu 800 (3) 3/0–750 kcmil Al/Cu (3) 3/0–500 kcmil Al/Cu 1200 (4) 3/0–750 kcmil Al/Cu (4) 3/0–500 kcmil Al/Cu Standard Mechanical Lugs—Main Circuit Breaker Panel Type Circuit Breaker Type Lug Wire Rangeb Wire Range Wire Bending Space per CSA 100 FA, FH, FI (1) #14–3/0 Al/Cu (1) #14–3/0 Al/Cu 100 HD, HG, HJ, HL (1) #14–3/0 Al/Cu (1) #14–3/0 Al/Cu 150 - 175 A JD, JG, JJ, JL 1/0–4/0 Al/Cu 1/0–4/0 Al/Cu 200 - 250 A JD, JG, JJ, JL 3/0–350 kcmil Al/Cu 3/0–350 kcmil Al/Cu Ampere Rating I-LINE 225 KI (1) #4–300 kcmil Al/Cu (1) #4–300 kcmil Al/Cu 400 LA, LH, LC, LX, LE, LI. LXI (1) #1–600 kcmil Al/Cu (2) #1–250 kcmil Al/Cu (1) #1–600 kcmil Al/Cu (2) #1–250 kcmil Al/Cu 600 LC, LX, LE, LI, LXI (2) 4/0–500 kcmil Al/Cu (2) 4/0–500 kcmil Al/Cu 600, 800 MG, MJ (3) 3/0–500 kcmil Al/Cu (3) 3/0–500 kcmil Al/Cu 800 PG, PJ, PL (3) 3/0–500 kcmil Al/Cu (3) 3/0–500 kcmil Al/Cu Backfed Main Breaker kits To be used in Canada only, to utilize a branch breaker in the I-Line panel as a Main Breaker by back feeding it. The use and correct application of these kits and attached labels are mandatory in such applications. Branch breakers to be used with FITC & HCBFMBL FI FAHCTC & HCBFMBL FA, FH, FC HDTC & HCBFMBL HD, HG, HJ, HL QTC & HCBFMBL QD, QG, QJ KAHCITC & HCBFMBL KA, KH, KC, KI JDTC & HCBFMBL JD, JG, JJ, JL LAHTC & HCBFMBL LA, LH LCIXETC & HCBFMBL LC, LI, LX, LE MGJTC & HCBFMBL MG, MJ PA8TC & HCBFMBL PG, PJ, PL, PK (800A max bkrs) PA12TC & HCBFMBL PG, PJ, PL, PK (1200A max bkrs) RA12TC & HCBFMBL RG, RJ, RK, RL (1200A max bkrs) DE5 PANELBOARDS Backfed Main breaker kits part numbers I-LINE 200% Rated Neutral—Standard Terminal Configuration ❑ Panel Type HCM ❑ h ❍ Ampacity 600 A 800 A 600 A (MG, MJ) 800 A (MG, MJ) Type MLO MLO M/B M/B Branch Space IN 72 72 72 72 Neutral Terminals Quantity & Size mm 1829 1829 1829 1829 Main (8) 600 kcmil HCP 600 A M/B MLO 63 1600 (8) 600 kcmil HCP-SUh 800 A M/B MLO 54 1371 (8) 750 kcmil HCR-U❍ 1200 A Universal 108✴ 2743 (8) 750 kcmil Branch (35) 350 kcmil (9) #14–1/0 (17) #14–#4 (35) 350 kcmil (9) #14–1/0 (17) #14–#4 (8) 750 kcmil (21) 350 kcmil (9) #14–1/0 (17) #14–#4 (8) 600 kcmil (15) 350 kcmil (9) #14–1/0 (17) #14–#4 H IN 91.00 mm 2311 Type 1 Enclosure W IN mm 32.00 D IN mm 8.25 210 9.50 241 813 68.00 1727 42.00 1067 9.50 241 86.00 2184 26.00 660 9.50 241 86.00 2184 44.00 1118 9.50 241 Available in Type 1 and 2 enclosures only. 9" box extension is required for HCP-SU panelboard with 200% rated neutral 6" box extension is required for HCR-U panelboard with 200% rated neutral Note: 1. Subfed kit # S33931 or back fed P-frame main breaker requre 9” mounting space – branch space reduced to 99”. 2. Subfed kit # S33930 or back fed R-frame main breaker requre 15” mounting space – branch space reduced to 93”. 3. 1200A HCR-U interior – copper bus standard 12/08 DE5-23