® RL with Anthony Doors Data Sheet Set Merchandisers P/N 0387184F NSF ® Certified January, 2003 K E I H J Warning: Terminal block NOT for case-to-case wire connection! A D B F G C Item Part # Description Wiring Item # FAN ASSEMBLIES, AND THERMOSTATS A. Fan Assembly 0047000 Standard motor 0315470 Fan Blade, 34º pitch 0439053 Optional Energy Efficient Motor B. 0386938 Standard Non-adjustable Defrost Thermostat C. Optional Adjustable Refrigeration Thermostat D. 0344662 Defrost Limit Thermostat E. 0338130 Relay Control Thermostat or Fan and Anti-sweat Heater Thermostat RELAYS F. 0342598 G. 0342599 Anti-Sweat Control Relay (120V) Fan Control Relay (208V) (1) Item 0387032 0387033 0387034 0387035 (2) (2) (2) (2) 0387036 0387037 0387038 0387039 (1) (1) (1) (1) I. (4) (5) (6) (Qty) HEATERS H. (2) (3) Part # LAMPS AND BALLASTS J. (7) K. Description Wiring Item # Electric Defrost Heaters (8) Front & Rear (208V) 2 Door Models 3 Door Models 4 Door Models 5 Door Models Drain Pan Heater (9) (Electric & Kool Gas) (120V) 2 Door Models 3 Door Models 4 Door Models 5 Door Models One-Lamp Ballast Two-Lamp Ballast Export Ballast Fluorescent Lamp, Standard 40W Refer to door manufacturer’s manual for replacement door parts. NOTE: Changed items have been underlined. HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. P/N 0387184F 08-2002 01-2003 Engineering Plan Views Reach-In 2, 3, 4, & 5 Door RL-RM-RMF Plan View Dimensions shown as in. & (mm). A B C D 32 (813) 6 41 9/16 (1056) (879) 5 3/8 (1219) Skid/External Base 34 5/8 (152) 48 Bottom Frt. Support Waste Outlet 39 3/8 (142) (999) 41 5/8 (1056) Refrig. Outlet (1110) Electrical Wireway 4 (102) Front 3 43 3/4 Water Seal (see note **) Relay & Terminal Block Location (76) 4 3 (102) (see note *) (76) 2 Dr 3 Dr 62 (1575) 43 3/4 (1111) 92 1/2 (2350) 43 3/4 (1111) 39 3/8 (1000) 4 1/2 (114) 6 (152) 6 3/8 (1000) 39 3/8 (1000) 4 1/2 (114) 6 (152) 6 3/8 (1000) 4 (102) 58 (1473) 41 5/8 (1057) 4 (102) 88 1/2 (2248) 41 5/8 (1057) Waste Outlet (C) Right end of case to center of waste outlet Back O/S of case to center of waste outlet 23 3/4 (603) 34 5/8 (879) 54 1/4 (1378) 34 5/8 (879) 46 1/4 (1175) 34 5/8 (879) 76 5/8 (1946) 34 5/8 (879) Water Seal Edge of water seal to center of waste outlet Outside diameter of drip piping 11 (279) 1 1/4 (32) 11 (279) 1 1/4 (32) 11 (279) 1 1/4 (32) 11 (279) 1 1/4 (32) 5 3/8 (137) 32 (813) 5 3/8 (137) 32 (813) 5 3/8 (137) 32 (813) 5 3/8 (137) 32 (813) 6 3/4 (170) 24 (610) 6 3/4 (170) 24 (610) 6 3/4 (170) 24 (610) 6 3/4 (170) 24 (610) General (A) Case Length (without ends or partitions) Maximum O/S dimension of case back to front 4 Dr 5 Dr 122 7/8 (3121) 153 3/8 (3896) 43 3/4 (1111) 43 3/4 (1111) (Includes bumper) Back of case to rear of splashguard Width of Skidrail Width of Bottom Front Support Stub-up area between front skidrail and splashguard Electrical Service RH end of case to the center of nearest knockout (B) RH end of case to the center of LH knockout Back O/S of case to center of knockout 39 3/8 (1000) 4 1/2 (114) 6 (152) 6 3/8 (1000) 39 3/8 (1000) 4 1/2 (114) 6 (152) 6 3/8 (1000) 4 (102) 4 (102) 118 7/8 (3019) 149 3/8 (3794) 41 5/8 (1057) 41 5/8 (1057) * NOTE: Electrical Field Wiring Connection Point is at terminal. ** NOTE: Field installed water seal outlets, tees, and connectors are shipped with case Refrigeration Outlet RH end of case to center of RH refrigeration outlet Back O/S of case to center of refrigeration outlet (D) Outside bottom front supports from end of case Center bottom front support from Centerline Distance between Center and Outside supports will vary 2 of 6 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. RL with Anthony Doors Data Sheet Set Reach-in 2, 3, 4 and 5 Door Models RL Impact With Anthony Doors Frozen Food & Ice Cream Dimensions shown as in. & (mm). 40 3/4 RL/RM/RMF REFRIGERATION DATA (1035) Note: This data is based on store temperature and humidity that does not exceed 75°F and 55% R.H. FF IC Discharge Air (°F) –5 –12 Evaporator (°F) –11 –19 Unit Sizing (°F) –14 –22 Btu/hr/Door* FF IC Parallel 1560 1650 Conventional 1600 1690 2 (52) 82 *For all refrigeration equipment other than (2083) Hussmann, use conventional Btu values. 62 1/2 67 (1588) (1700) Frame DEFROST DATA Frequency (hr) Defrost Water (lb/Dr/day) FF 24 1.2 IC 24 1.2 (± 15% based on case configuration and product loading). ELECTRIC 22 Temp Term (°F) Failsafe (minutes) Shelf FF 48° 40 IC 48° 40 20 20 GAS (559) Duration (minutes) OFFTIME Not Recommended 27 5/8 (702) CONVENTIONAL CONTROLS Refrigeration Outlet Fan Low Pressure Backup Control FF IC CI/CO (Temp °F)** –18°/ –34° – 26°/ –45° Coil 13 (332) 4 3/4 (121) Electrical Field Wiring Connection is at Terminal Electrical Stub-up Area 3 7/8 1 1/2 (97) (38) 32 (813) 5 34 /8 (879) 39 3/8 (999) 41 5/8 (1056) 43 3/4 (1110) 2 5/8 (67) Indoor Unit Only, Pressure Defrost Termination (Temp °F)** Not Recommended **Use a Temperature Pressure Chart to determine PSIG conversions. PHYSICAL DATA Drip Pipe (in.) Liquid Line (in.) Suction Line (in.) 1 1/4 3/8 7/8 Estimated Charge (lb)*** 2Dr 1.8 3Dr 2.7 4Dr 3.6 5Dr 4.6 NOTE: The bumpers are 4 in. (102 mm) wide. The center of the bumper is ***This is an average for all refrigerant types. Actual refrigerant charge may vary by 5 1/2 in. (140 mm) from the floor. approximately half a pound. NSF Certification: These merchandisers are manufactured to meet ANSI/ National Sanitation Foundation (NSF®) Standard #7 requirements. P/N 0387184F Length Added to Lineup by each Standard End (in.) Optional End with Window (in.) Optional Partition (in.) HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. 2 1 1/2 1 1/2 3 of 6 RL Impact With Anthony Doors Frozen Food & Ice Cream Electrical Data Number of Fans 2Dr 3Dr 4Dr 5Dr 2 3 4 5 Merchandiser 2Dr Amperes 3Dr 4Dr Fans Standard Energy Efficient (Export: 220V 50 hz) 1.40 0..76 0.76 2.10 1.14 1.14 2.80 1.52 1.52 3.50 1.90 1.90 110 50 108 165 75 162 220 100 216 275 125 270 Anti-sweat Heaters Doors (Export: 220V 50 hz) 2.18 1.18 3.27 1.77 4.36 2.36 5.45 2.95 262 260 392 389 523 519 654 649 Frames (Export: 220V 50 hz) 1.60 0.88 2.35 1.27 3.06 1.68 3.81 2.08 192 194 282 279 367 370 457 458 5.36 4.64 20 20 7.90 6.86 20 20 Drain Heaters (120V) (Export: 220V 50 hz) 0.63 0.38 1.25 0.76 75 84 150 167 240 268 300 334 Φ Electric Defrost 208V 1Φ (Export: 220V 50 hz) 8.20 8.70 1706 1804 2720 2877 3734 3949 4750 5024 Standard Vertical Lighting 2Dr 3Dr 4Dr 5Dr 2Dr 3Dr 4Dr 5Dr Anthony Doors (120V) (Export: 220V 50 hz) 1.45 0.79 1.94 1.06 2.42 1.32 2.91 1.59 Ardco Doors (120V) (Export: 220V 50 hz) 1.89 NA 2.34 NA 3.06 NA 3.51 NA Min. Circuit Ampacity With Standard Fans With Energy Efficient Fans Max. Over Current Protection (Export: 220V 50 hz) 5Dr 2Dr Watts 3Dr 4Dr 5Dr 10.40 12.94 9.404 11.26 20 20 20 20 Defrost 4 of 6 13.0 13.8 2.00 1.22 18.0 19.0 2.57 1.52 22.8 24.2 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. RL with Anthony Doors Data Sheet Set Fan and Heater Circuits - Electric Defrost (standard) Low Temperature CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS R = Red P = Purple 2P = Purple (2 Bands) DB = Dark Blue B = Black THESE ARE MARKER COLORS (WIRE MAY VARY.) BR =Brown Y =Yellow OR = Orange W = White 208V 208V Evaporator Fan 7 Relay Coil 1 R 2 R 3 R 1 Rear Defrost Heater Front Defrost Heater C 3 4 R 8 R 8 R 7 8 Defrost Limit 4 6 Fan Relay 7 F N.C. Evaporator Fans Fan Relay 7 F N.O. Rod Heater (Drain) B A.S. Relay Coil 5 C.O.R. COM B 25 W 24 6 1 10 B Frame A.S. Heaters NEUTRAL 11 P Switch P 22 2P 21 Door A.S. Heaters L OR DB c Y Refer to door manufacturer’s manual for replacement part numbers of door parts. 6 N.C. 120V POWER FIELD WIRED 26 9 Y 3 A.S. Relay A.S. 17 1 BR Relay Control 13 NEUTRAL COM B 16 5 B O.O.R. N.C. 120V POWER 14 B CAUTION: When multiplexing merchandisers equipped with defrost heaters, if branch circuit over-current protection is larger than the individual merchandiser’s defrost circuit load, then additional supplemental over-current protection may be required per NEC Articles 210 and 240. Defrost Termination Thermostat 12 20 OR 2P DB Terminal Blocks in Raceway Low Temperature with Electric Defrost 2 Refrigeration Thermostat (Optional) 2 C.O.R. Defrost Termination Thermostat R R R R B B R R B P 2P B 1 2 3 4 5 6 7 8 10 11 12 13 Permanent Internal Removable External Jumpers DEFROST HEATERS Jumpers (208V) B B OR OR 2P 14 16 FANS & A.S. (120V) 17 20 21 3 Pink P W Y BR 22 24 25 LIGHTS LIGHTS (120V) (Neutral) 26 } To Condensing Unit Dark Blue FANS & A.S. (Neutral) Electric Defrost Sequence - Low Temperature 1. Power from the defrost contactor energizes Defrost Heaters and 208V Evaporator Fan Relay Coil (7). Relay Contacts open the fan circuit and energizes the Drain Pan Heater. 2. If the Defrost Heater raises internal air temperature above 90°F, the Defrost Limit Thermostat (4) will open. 3. Temperature rise of the evaporator closes the Relay Control Thermostat (5) at about 35°F, energizing 120V A.S. Relay Coil (6). This relay’s contacts open the Frame and Door Heater Circuits. 4. When Defrost Termination Thermostat ends defrost period, the defrost contactor opens the Defrost Heater and Evaporator Fan Relay Coil Circuits. The Drain Pan Heater goes off and fans are on. 5. Temperature fall of the evaporator opens the Relay Control Thermostat (5) at about 20°F, de-energizing 120V A.S. Relay Coil (6). A.S. Relay Contacts close the Frame and Door Heater Circuits. P/N 0387184F HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. 5 of 6 Fan and Heater Circuits - Gas Defrost (optional) Low Temperature CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS R = Red P = Purple 2P = Purple (2 Bands) DB = Dark Blue B = Black BR =Brown Y =Yellow OR = Orange W = White THESE ARE MARKER COLORS (WIRE MAY VARY.) NEUTRAL 120V POWER 14 Fan Relay 7 F N.C. COM B Fan Relay 7 Defrost Limit 4 F N.O. B B A.S. Relay Coil 5 3 c c C.O.R. 6 A.S. Relay A.S. 13 9 Rod Heater (Drain) O.O.R. Relay Control COM 26 BR Y 16 1 Evaporator Fans N.C. 25 W 24 6 1 Fan Relay 7 Coil 10 B Y Refer to door manufacturer’s manual for replacement part numbers of mullion, door frame, and perimeter antisweat heaters. Frame A.S. Heaters 11 P P 22 2P 21 Door A.S. Heaters 12 2P NEUTRAL 120V POWER Switch 17 L OR 20 OR Refrigeration Thermostat (Optional) Terminal Blocks in Raceway Low Temperature with Gas Defrost B P 2P B B 10 11 12 13 14 Removable External Jumpers FANS & A.S. (120V) B OR OR 2P 16 17 20 21 P W Y BR 22 24 25 LIGHTS LIGHTS (120V) (Neutral) 3 } Pink To Condensing Unit 26 FANS & A.S. (Neutral) Permanent Internal Jumpers Gas Defrost Sequence – Low Temperature 1. Defrost vapor enters evaporator causing a rise in temperature. At about 35°F the Control Relay Thermostat (5) closes the Fan Relay Coil (7) and Control Relay Coil (6) circuit. The Coil opens the Fan, Door Heater, and Frame Heater circuits, while energizing the Drain Pan Heater (9). 2. If the Drain Pan Heater (9) raises internal air temperature above 90°F, the Heater Limit Thermostat (4) will open. 3. When the defrost timer ends a defrost period, the evaporator temperature will start to fall. At about 20°F, the Control Relay Thermostat will open, de-energizing the Control Relay Coil and Fan Relay Coil (7). Control and Fan Relay’s will open the Drain Pan Heater circuits, and will close the Fan, Door Heater, and Frame Heater circuits. 6 of 6 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. RL with Anthony Doors Data Sheet Set