SYSTEM 1000
Modular
Instrumentation
www.cwe-inc.com
SYSTEM 1000 Instrumentation
MODEL BMA-931
AC/DC BIOAMPLIFIER
MED
500
BIO
200
X10
100
50
OFFSET
0
GAIN
1K 2K
5K
10K
20K
50K
1
3
HI
10
FREQ
50 (kHz)
.3
.1
Pull
On
BMA-931 Bioamplifier
DC
l Low-noise, DC-50kHz response, bandpass filters, adjustable DC offset
10 30
1
100
LO
300 FREQ
DC
AC
High-performance, low-noise AC/DC preamplifier for a variety of biopotential
recordings. Its wide bandwidth, sharp cutoff bandpass filters, and stable DC
response make this the ideal choice for EMG, ENG, ECG, and all extracellular
applications. Compatible with the SUPER-Z High-impedance head-stage, and the
ISO-Z Isolation Amplifier head-stage for safe human recording. A variety of electrodes and accessories is available.
Standard Features:
(Hz)
Applications:
l EMG, ENG, ECG, EOG and other extracellular recording
OUTPUT
Accessories:
l SUPER-Z head-stage, ISO-Z isolated head-stage, pre-wired cables
l MA-1000 Moving Averager, WD-1000 Window Discriminator
SYSTEM 1000
CWE, INC.
MODEL PM-1000
TRANSDUCER AMPLIFIER
PM-1000 Transducer Amplifier
Versatile amplifier for DC bridge-type transducers, including pressure, force,
and acceleration. Works directly with most resistive bridge and solid-state transducers. Features very low drift and adjustable DC excitation voltage. Its wide sensitivity range, built-in low-pass filters (including mean pressure), and industry
standard input connector make the PM-1000 ideal for most transducer applications. It can also be used as a stable differential DC preamplifier.
Standard Features:
BALANCE SENSITIVITY
200
100
20
1V
10
2
2
10
FILTER
POSITION
0
Pull
On
ATTEN
1mV
50
0
X1
100
10
500
.1
(Mean)
5K
Hz
l Low-noise, DC-5kHz response, stable balancing, low drift, GrassTM compatible
l Fine control of sensitivity with stepwise setting and continuous attenuator
BRIDGE GND DC AMP
INPUT
Applications:
OUTPUT
l Blood pressure, airway pressure, force, acceleration, differential DC amp
Accessories:
l DTX-1 blood pressure transducer
l PS-1000 series transducers for air and gasses
SYSTEM 1000
CWE, INC.
PA-931 PRESSURE
PA-931 Transducer Amplifier
BALANCE
SENSITIVITY
FILTER
RANGE
Inexpensive, easy to use DC bridge amplifier for a variety of transducer applications. Features wide gain range and 3-position low-pass filter. Directly compatible with GrassTM pressure and force transducers. Ten-turn dials are provided for
setting sensitivity and balance.
Standard Features:
MEAN
X100
l DC-5kHz response, stable balance adjustment, low-drift, GrassTM compatible
OFF
1KHz
Applications:
X10
lBlood pressure, airway pressure, force measurements
INPUT
OUTPUT
Accessories:
l DTX-1 blood pressure transducer
l PS-1000 series transducers for air and gasses
SYSTEM 1000
CWE, INC.
P H Y S I O L O G Y
•
R E S P I R A T I O N
•
A N E S T H E S I A
•
D ATA
A C Q U I S I T I O N
CWE, Inc. 25 St.Paul’s Road, Ardmore, PA 19003 U.S.A.
www.cwe-inc.com 610-642-7719 FAX 610-642-1532
SYSTEM 1000 Instrumentation
MA-1000
MOVING AVERAGER
MA-1000 Moving Averager
The Moving Averager is used to quantify nerve and muscle electrical activity.
This module comprises an adjustable gain input amplifier, precision full-wave rectifier, and selectable time-constant Moving Averager (Paynter Filter). The larger
the time constant, the greater the smoothing effect of the filter. Standard time constants are 50, 100, and 200mS; the values most often used for EMG and ENG
recording. Other values between 10mS and 500mS are available and can be
installed by the user via convenient plug-in modules.
Standard Features:
GAIN
X1
TIME
CONSTANT
mS
X10
DC OFFSET
200
PULL
ON
100
RECT OUT
50
INPUT
l Pushbutton time constant selection, adjustable gain and output offset
l Rectified and Moving Average outputs, switchable AC or DC coupling
M.A. OUT
DC
Applications:
l Nerve and muscle electrical activity measurement
AC
Accessories:
SYSTEM 1000
l BMA-931 Bioamplifier, additional MA-821-TCM time constant modules
TM-1000
TEMPERATURE MODULE
37.0
TM-1000 Temperature Measurement Module
This microprocessor-based module accepts standard YSI-400 series thermistor
probes for measurements in the range 0 - 50oC, or 32 - 122oF. Temperature is displayed on a digital readout in degrees C or F, and an analog output is provided for
external recording. A built-in high/low adjustable provides and audible warning if
the monitored temperature goes outside the alarm settings.
Standard Features:
C
F
ALARM SET
HIGH
ALARM
LOW
DISPLAY
CENT.
BEEP
ON
FAHR.
OFF
l 4-digit display, 12-bit D/A output, selectable for display of oC or oF
l Adjustable high and low alarm
ALARM OUT
Applications:
PROBE
l Monitoring body temperature or bath temperature
TEMP OUT
Accessories:
l Thermistor probes available for rectal body temperature on a variety of animals,
including mice.
SYSTEM 1000
CWE, INC.
DC-936 BUFFER
INPUT
DC-936 Six-channel DC Buffer Amplifier
OUTPUT
GAIN
1
POS
GAIN
2
POS
GAIN
3
POS
GAIN
4
POS
GAIN
5
POS
GAIN
6
POS
This module provides six independent DC buffer amplifiers, each with
adjustable gain, offset, and polarity. These amplifiers are used to boost, attenuate,
offset, or invert signals going from one piece of equipment to another. Typical
applications include adjusting signal levels for data acquisition systems. Gain and
offset are set using screwdriver-adjust potentiometers. Once you have one of these,
you will find it indispensible!
Standard Features:
1
2
3
4
l Adjustable gain 0.1 - 10X, +10V DC offset, invert/non-invert, BNC jacks
5
Applications:
l Interfacing to data acquisition systems, general purpose signal manipulation
6
Accessories:
l BNC patch cables
SYSTEM 1000
CWE,INC.
P H Y S I O L O G Y
•
R E S P I R A T I O N
•
A N E S T H E S I A
•
D ATA
A C Q U I S I T I O N
CWE, Inc. 25 St.Paul’s Road, Ardmore, PA 19003 U.S.A.
www.cwe-inc.com 610-642-7719 FAX 610-642-1532
SYSTEM 1000 Instrumentation
CT-1000
CARDIOTACHOMETER
CT-1000 Cardiotachometer
The CT-1000 is an advanced, microprocessor-based instrument for the accurate measurement of heart rate and beat-to-beat interval measurement. It has a
built-in medical-grade isolation amplifier for direct ECG electrodes, and also
accepts high-level signals such as arterial BP. The CT-1000 features one button
setup and automatic tracking of signal levels. Outputs available are: amplified
ECG, R-wave logic signal, and analog rate (or interval) output signal.
BPM
mS
ECG
LOCK
ERR
MAN
SETUP
SAT
AMP OUT
GAIN
AUTO
CAL
60 bpm HI LEVEL
BEEP
ON
120 bpm LO LEVEL OFF
ANALOG OUT
Standard Features:
RATE
l R-wave detection, rate or interval updated on each beat
l Direct, isolated ECG electrode inputs or BP signal input
R-R INT
INPUT
R OUT
NORM
ISO
Applications:
INVERT
l Accurate heart rate and R-R interval measurement
Accessories:
l Pre-wired input cable & electrodes, PM-1000 amplifier & BP transducer
CWE, INC.
RIC-1000
RATE/INTERVAL COUNTER
DATA
CONT
INTERVAL
S/H
INPUT
The RIC-1000 is a versatile instrument for measuring the frequency or interval of pulse-type events. A crystal timebase provides resolution to 100uS. The
count can be updated continuously, or at the end of each interval (sample/hold).
This allows histogram frequency displays or trend lines. The RIC-1000 requires
only the input signal to function; no external gating or reset pulses are required.
The wide-range timebase allows measurements over five decades, or more using
the external clock input.The RIC-1000 makes the perfect companion to the WD1000 Window Discriminator.
Standard Features:
.0001
.001
.01 TIME
.1
BASE
1
(SEC)
10
EXT
CLOCK
OVER
RATE
RIC-1000 Rate/Interval Counter
l 4-digit display, 12-bit D/A output, wide timing range, flexible counting modes
l Positive/negative trigger select, Schmitt trigger input
OUTPUT
TRIG
POS
NEG
Applications:
l Nerve firing frequency, general purpose rate or interval measurement
Accessories:
l WD-1000 Window Discriminator
CWE, INC.
WD-1000
WINDOW DISCRIMINATOR
WD-1000 Time/Amplitude Window Discriminator
LEVEL A
The window discriminator is used to separate single neuron action potentials
from multi-unit recordings. It can operate as a classic voltage amplitude window
discriminator, or as a time/amplitude discriminator. In the latter mode, the signal
must fall within a voltage and an adjustable time window. This permits separating
similar pulses that differ only in timing. Outputs are available from both window
levels, a data output, and an independent trigger output for synchronizing the oscilloscope trace. These outputs allow simultaneous discrimination of three signals.
Standard Features:
TIME POSITION
LEVEL B
MODE SLOPE
TIME/AMP POS
DATA
DATA OUT
AMPLITUDE NEG
THRESHOLD
A OUT
B OUT
INPUT
SCOPE TRIG
MPX OUT
l Voltage or time/amplitude window, multiplexer and scope trig outputs
l Separate outputs for each level crossing
Applications:
l Discrimination of single units from multi-unit recordings
Accessories:
l BMA-931 Bioamplifier, RIC-1000 Rate/Interval Counter
CWE, INC.
P H Y S I O L O G Y
•
R E S P I R AT I O N
•
A N E S T H E S I A
•
D ATA
A C Q U I S I T I O N
CWE, Inc. 25 St.Paul’s Road, Ardmore, PA 19003 U.S.A.
www.cwe-inc.com 610-642-7719 FAX 610-642-1532
SYSTEM 1000 Instrumentation
ALM-932
ALARM MODULE
ALM-932 Two-Channel Alarm/Monitor
Monitors the output of any two channels in the card-cage, and signals an alarm
condition if preset limits are exceeded. Adjustable high and low alarms are provided for each channel. LED indicators show which alarm condition exists, and a
beeper (switchable) provides an audible warning. Digital meters show signal voltage, which can be calibrated to reflect “real-world” measurements. Logic outputs
are provided for all alarms, and are accessible on the rear edge-card connector.
CAL
HI
LO
A
CHANNEL
2 3 4
5
LO LIMIT
HI LIMIT
SET ALARM
HI
ON
1
SET
LO
OFF
CAL
HI
Standard Features:
LO
B
CHANNEL
2 3 4
5
LO LIMIT
HI LIMIT
l Wide input range, adjustable high and low alarms
l Logic outputs for external control or monitoring of alarms
SET ALARM
HI
ON
1
SET
LO
OFF
Applications:
l Blood pressure, heart rate limit alarms
l Body temperature, expired CO2 alarms
SYSTEM 1000
CWE,INC.
MODEL DF-932
DIFFERENTIATOR
DF-932 Two-Channel Differentiator
SENSITIVITY
Two channel processor that produces the first derivative of the input signal.
Useful in cardiac studies for creating dP/dt of pressure waveforms.The second
derivative (acceleration) can be produced by cascading the two channels. Ten calibrated sensitivity settings cover the range 20 - 200V/s, where each setting corresponds to the input slope required to produce 1V output.
V/S
POSITION
100 120
0
80
Pull
On
140
60
160
40
180
20
200
INPUT SLOPE TO
PRODUCE 1V OUTPUT
INPUT
OUTPUT
CHANNEL A
SENSITIVITY
V/S
POSITION
100 120
0
80
Pull
On
Standard Features:
140
60
160
40
l Wide sensitivity range
l Two independent channels, can be cascaded for acceleration studies
180
20
200
INPUT SLOPE TO
PRODUCE 1V OUTPUT
OUTPUT
INPUT
Applications:
CHANNEL B
l Cardiac output, blood flow studies
l Volume to flow conversion
SYSTEM 1000
CWE, INC.
MODEL BPF-932
BAND-PASS FILTER
100
LOW
Hz
FREQUENCY
BPF-932 Two-Channel Bandpass Filter
30
0.01 HIGH
KHz
0.1
10
0.3
3
High-performance bandpass filter. High-pass settings from DC to 100Hz.
Low-pass settings 10Hz to 50kHz. Uses 2-pole active filters with Butterworth
response for minimum amplitude distortions in passband. Overall gain is jumper
selectable for X1 or X10. Useful for filtering transducer signals to reduce high-frequency noise, and for selective filtering of biopotentials such as EMG or EEG.
1
0.1
DC
10
50
INPUT
OUTPUT
CHANNEL A
100
LOW
Hz
FREQUENCY
0.01
30
0.1
10
0.3
3
Standard Features:
HIGH
KHz
l High-pass settings: DC, 0.1, 3, 10, 30, and 100Hz
l Low-pass settings: 10, 100, 300Hz, 1, 10, 50kHz
l -12dB/octave cutoff slope
1
0.1
DC
10
50
OUTPUT
INPUT
CHANNEL B
Applications:
l Transducer conditioning
l Filtering of EMG and other biopotentials
l Cleaning up signals prior to data acquisition
SYSTEM 1000
CWE, INC.
P H Y S I O L O G Y
•
R E S P I R AT I O N
•
A N E S T H E S I A
•
D ATA
A C Q U I S I T I O N
CWE, Inc. 25 St.Paul’s Road, Ardmore, PA 19003 U.S.A.
www.cwe-inc.com 610-642-7719 FAX 610-642-1532
SYSTEM 1000 Instrumentation
PI-1000 INTEGRATOR
PI-1000 Respiratory Integrator
BALANCE
The PI-1000 is a low-drift integrator intended primarily for respiratory airflow
studies. Two independent matched integrators allow a variety of breath-by-breath
or cumulative volume waveforms to be produced. A wide time-constant range covers the full range of animal and human measurements. A built-in low-pass filter
reduces noise from valve flutter or transducer vibration. The integrator is typically used with a pneumotach, sensitive differential pressure transducer, and transducer amplifier for a complete measurement system.
Standard Features:
TIME
CONSTANT
.2
.5
INS
.1
1
.05
2
.02
.01
5
EXP
PROGRAM
RESET
INS
ON
EXP
ON
OFF
OFF
EXT RESET
BOTH
RESET
LEVEL
SB
RAMP
INPUT
FILTER
l Very low drift, single breath or cumulative volume, automatic reset
OUTPUT
15Hz
Applications:
OFF
l Respiratory volumes, general purpose signal integration
75Hz
Accessories:
l Pneumotach, PS-1000/A-004 transducer, PM-1000 Transducer Amplifier
CWE,INC.
DI-1040
EXPANDER MODULE
CHAN.6
DI-1040 Eleven-channel Expander Module
CHAN.7
CHAN.8
CHAN.9
CHAN.10
CHAN.11
CHAN.12
CHAN.13
CHAN.14
Used with the Dataq WinDaq data acquisition system (and others) to provide
direct access to channels 6 through 16. It is always used in the sixth module slot
(right-hand side), where its outputs are automatically fed to the rear panel 37-pin
D-SUB connector. The DI-1040 is used with high-level signals, and is configured
by jumpers for +2.5, 5, or 10V input ranges. Custom gain settings can also be configured by resistor selection.
Standard Features:
l Selectable gain, non-inverting operation, high input impedance, BNC jacks
CHAN.15
Applications:
CHAN.16
l Access channels 6 - 16 of data acquisition system
Accessories:
l WinDaq data acquisition hardware and software
CWE, INC.
BL-1000 Blank module for custom instrumentation
This module is for those desiring to create custom circuitry using the same
form factor as the other SYSTEM 1000 modules. Included is a blank module with
clear anodized aluminum finish and an installed prototyping circuit board. The circuit board has a gold-plated edge connector, power busses, silk-screened labels,
and plated-through holes for easy and reliable circuit construction.
Standard Features:
l Complete package for creating custom SYSTEM 1000 module
Applications:
l Custom circuitry for special functions
P H Y S I O L O G Y
•
R E S P I R AT I O N
•
A N E S T H E S I A
•
D ATA
A C Q U I S I T I O N
CWE, Inc. 25 St.Paul’s Road, Ardmore, PA 19003 U.S.A.
www.cwe-inc.com 610-642-7719 FAX 610-642-1532
SYSTEM 1000 Accessories
SUPER-Z High-Impedance Head Stage
SUPER-Z
CAL
20uV
50
OFFSET
USE
CAL
X10
AC
X1
DC
200
C
500
1mV
CWE
An auxiliary high-impedance probe for use with the BMA931 Bioamplifier and other CWE amplifiers using a 7-pin
Amphenol input connector. Precision, low-drift input buffers with
very high impedance allow the SUPER-Z to be used with any
electrode type. Provides switchable 1X/10X gain, a 5-step microvolt calibrator, and precision DC offset control. Standard 2mm
pin jacks for input, with 12-ft cable to amplifier.
ISO-Z Isolation Amplifier Head Stage
ISO-Z
C
Isolation
Head-Stage
CAL
500uV
P-P
ISO
CWE, INC.
NOT FOR USE
WITH LIQUIDS
PS-1000 Series Pressure Transducers
PS-1000/A
PRESSURE TRANSDUCER
MAX DIF PRESSURE
75cmH2O
GAIN=10
A medical-grade isolation amplifier head stage for use with
the BMA-931 Bioamplifier and other CWE amplifiers. Provides
complete electrical isolation for safe recording from human subjects. Fixed gain of 10X, with pushbutton AC calibrator.
TouchProof 1.5mm DIN jacks for input, with adapters supplied
for use with 2mm pin plugs.
These are differential, solid-state pressure transducers for use
with air or non-corrosive gasses only (not for use with liquids).
They are accurate, stable, and inexpensive. The PS-1000/A-1 has a
range of +70cmH2O, which is ideal for respiratory pressure measurements. Model PS-1000/A-004 has a range of +10cmH2O, and
is used with a pneumotach for respiratory airflow measurements.
DTX Blood Pressure Transducers
These are industry standard, solid-state, electrically isolated
blood pressure transducers. They are nominally single-use for
humans, but can be cleaned and re-used indefinitely with animals.
Available individually or in sterile packs of ten. Requires TC-GRA
adapter cable.
Input cables, electrodes, and misc.
A variety of pre-wired input cables, ECG and EMG electrodes, and adapter cables is available. Un-wired input
connectors are supplied with each amplifier, ready for custom wiring. Pre-wired cables are are 3m long, with 2mm
pin jacks for electrode wire connection. Disposable electrodes, as well as high-quality re-usable Ag-AgCl electrodes and accessories are available. Consult the Price List for ordering information.
General Information
SYSTEM 1000 is a flexible and economical modular instrumentation system. To use the modules described
here, you need a CC-1000 card-cage (six module size) or CC-1000/3 (three module size). Each comes with a universal-input power supply. For benchtop placement, a handsome and rugged molded DeskTop Enclosure is
availalble.
SYSTEM 1000 can be used as a versatile, direct-connect signal conditioning front-end for your data acquisition system. The CC-1000 card-cage has a DB-37 output connector that feeds the module output signals directly
to most data acquisition systems.
Notes:
1. SYSTEM 1000 components are not to be used for Human Life Support Applications.
2. Specifications subject to change without prior notice.
P H Y S I O L O G Y
•
R E S P I R A T I O N
•
A N E S T H E S I A
•
D ATA
A C Q U I S I T I O N
CWE, Inc. 25 St.Paul’s Road, Ardmore, PA 19003 U.S.A.
www.cwe-inc.com 610-642-7719 FAX 610-642-1532
SYSTEM 1000 Instrumentation
CC-1000 Six Module Card-Cage
This is a rackmount or benchtop
card-cage that is the
foundation of any
SYSTEM 1000
setup. It fits into a
standard 19" equipment rack, and
occupies 3U (5.25") height. The card-cage holds up to six instrumentation modules of your choice. DC power
for the modules is introduced via a DIN connector accessible from the rear of the chassis.
Individual channel inputs and outputs are available on the motherboard at the back of the chassis. A D-SUB
37-pin connector also provides all channel outputs, and is directly compatible with the Dataq Instruments
WinDAQ data acquisition system. A handsome molded desktop enclosure (Model DTE-1000) is available as an
option. Also available is a 3-module card-cage (Model CC-1000/3), with corresponding desktop enclosure
(Model DTE-1000/3).
Standard Features:
Power supply to card-cage
connector
l Holds six modules; three module card-cage also available
l Shielded enclosure fabricated from aluminum with steel covers
l Standard CC-1000 comes with universal power supply
-12V
+12V
2
4
5
+5V
Options:
l DTE-1000 Desktop enclosure
l CC-1000/ADP power splitter cable
l CC-1000/3 Three-module card-cage
3
1
GND
DIN Cable Plug
SYSTEM 1000 Power Supply
This is the standard power supply furnished with the
CC-1000 card-cage. It is a universal input supply that
accepts 95-240VAC, and features a standard detachable
power cord. The output cable is 6' long and terminated
with a DIN plug which mates with a jack on the rear
panel of the CC-1000 card-cage. This power supply has
sufficient capacity to provide power to two CC-1000
card-cages (up to 12 modules). To do this, model
CC-1000/ADP adapter cable is required.
Features and Specifications:
Input range . . . . . . . . . . . . . . .95-240VAC, 50/60Hz
Max power consumption . .1A @115V, 0.5A @ 230V
Output . . . . .+5V @ 2A, +12V @ 1.5A, -12 @ 0.3A
Dimensions . . . . . . . . . . . . .6.5L x 3W x 2D inches
P H Y S I O L O G Y
•
R E S P I R AT I O N
•
Note: Be sure to indicate the country where the
SYSTEM 1000 instrumentation will be used. We
will then be able to provide the correct power supply cord.
A N E S T H E S I A
•
D ATA
A C Q U I S I T I O N
CWE, Inc. 25 St.Paul’s Road, Ardmore, PA 19003 U.S.A.