"%*/4536.&/54 Quad and Octal Bridge Amps Signal Conditioners Description The ML118 Quad and ML119 Octal Bridge Amps are optimized for use with multiple chamber organ baths. They provide a fast software or switch initiated zeroing capability. Each input consists of a software controlled nonisolated, low-noise bridge amplifier suitable for use with full bridge strain gauge type transducers. Compatibility The Quad and Octal Bridge Amps are compatible with all PowerLab and MacLab systems and require Chart v4 or later or Scope v3.6 or later. The following are some of the transducers suitable for use with the Quad and Octal Bridge Amps: MLT0380/D MLT844 MLT1199 MLT0015 MLT0202 MLT0201 MLT0210/D MLT500/D MLT050/D MLT003/D Reusable BP Transducer Physiological Pressure Transducer Blood Pressure Transducer /Cable Kit High Grade Isotonic Transducer Sensitive Isometric Force Transducer (0-25 g) Force Transducer (5 - 25 g) Teaching Force Transducer Force Transducer (0 - 500 g) Force Transducer (0 - 50 g) Hand Dynamometer For transducers with Grass connectors, an MLAC18 Grass Adapter Cable is required for use with ML118 or ML119 Bridge Amps. Applications Used for measuring force, displacement and physiological pressures. Ideal for multichannel isolated tissue studies. Specifications Input Number of inputs: 4 (Quad) or 8 (Octal) (8-pin DIN) Input configuration: Single-ended, with differential to single ended conversion for 4-arm bridges. Amplification range: ±20 µV to ±200 mV full scale in 13 steps (combined PowerLab and Bridge Amp) ±200 mV ±100 mV ±50 mV ±20 mV ±10 mV ±5 mV ±2 mV ±1 mV ±500 µV ±200 µV ±100 µV ±50 µV ±20 µV Amplification accuracy: ±0.25% (combined PowerLab & Bridge Amp; with 0 to 5 kΩ input source resistance) Maximum input voltage: ±10 V, continuous Input impedance: Over 108 Ω for signals up to ±0.5 volts (1 kΩ above ±0.5 volts). Low-pass filtering: 1 Hz to 100 Hz in seven steps (software selectable), using fourth-order Bessel filters (for constant time-delay) AC coupling: Not provided Input referred noise: 350 Ω resistor between input and ground to simulate bridge, 50 µV range, over 5 sec LP Setting Noise 100 Hz 1.3 µVrms 50 Hz 1.1 µVrms 20 Hz 0.58 µVrms 10 Hz 0.36 µVrms 5 Hz 0.36 µVrms Amplifier offset: ±0.2% f.s. ±10 µV (with no zeroing applied) Amplifier drift: <0.3 µV per °C at 1 mV range or lower (with low-resistance input) Excitation and Zeroing Excitation voltage range: DIN: 8 volts DC (±4 V referred to ground) Excitation voltage accuracy: ±0.25% Excitation current: Limited to about 25 mA per transducer Min. transducer impedance: 350 Ω Max. transducer impedance: 2.50 kΩ recommended Bridge configurations: 4-arm bridge standard, 2-arm requires fix with 2 matched high-precision resistors Offsetting capability: ±150 mV with 16-bit internal DAC giving c. 4.5 µV offsetting resolution (fixed) Zeroing circuitry: Software-controlled, either manual or automatic; or using external switches Stabilization time: 15 seconds maximum (after power-up and before I2C commands are accepted) Auto-zeroing time: 1 second per channel re-zeroing (with stable input) Status Indicators Diagnostic lights: Status indicators give information for each channel on warm-up sequence, zeroing, and possible faults, such as transducer overload Control Port I2C port: Power and control bus for front-end units. Supports a number of front-ends dependent on the PowerLab. Interface communications rate of ~50 Kbits/s. Physical Configuration ML118 (Quad) (w × d × h): 300 mm × 300 mm × 60 mm (11.8" × 11.8" × 2.4") 3.1 kg (6 lb 12 oz.) Weight: ML119 (Octal) (w × d × h): 300 mm × 300 mm × 60 mm (11.8" × 11.8" × 2.4") 3.4 kg (7 lb 8 oz.) Weight: Power requirements: 1.8 W (with no transducers) 5.25 W (4 × 350 Ω transducers, 8V excitation) 10.5 W (8 × 350 Ω transducers, 8V excitation) Operating temperature range: 5 to 40 °C, 0 to 90% relative humidity (non-condensing) ADInstruments reserves the right to alter these specifications at any time Front and Back Panels ADINSTRUMENTS Quad Bridge Amp 1 Status Quad Bridge Amp Octal Bridge Amp 2 Zero Status 3 Zero Status 4 Zero Status Zero WARRANTY: ADInstruments PowerLab Systems, Front-end and Pod Signal Conditioners are warranted against defects in materials and workmanship for a period of 3 years from the date of purchase. Third party products are covered by the manufacturer’s warranty. Warranties are void if the product has been damaged due to negligence. Consumables and electrodes are not covered by a warranty. All questions regarding service and warranty should be directed to your nearest ADInstruments representative or one of the offices listed below. Caution Read “Statement of Intended Use” on our website or in “Getting Started with PowerLab” before use. Ordering Information ML118 Quad Bridge Amp ML119 Octal Bridge Amp ML118 Includes: I2C Cable (9-pin plug to 9-pin receptacle) BNC to BNC Cables (4) DIN Connector Kits (4) Bridge Amp Owner’s Guide ML119 Includes: I2C Cable (9-pin plug to 9-pin receptacle) BNC to BNC Cables (8) DIN Connector Kits (8) Bridge Amp Owner’s Guide A MLAC18 Grass Adapter Cable may be ordered as an optional extra. ML118_119-DC-05A ADINSTRUMENTS.com ISO 9001:2000 Certified Quality Management System North America United kingdom Tel: +1 888 965 6040 Fax: +1 866 965 9293 info@adinstruments.com Tel: +44 1865 891 623 Tel: +49 6226 970105 Tel: +86 21 5830 5639 Tel: +60 3 8023 6305 Fax: +44 1865 890 800 Fax: +49 6226 970106 Fax: +86 21 5830 5640 Fax: +60 3 8023 6307 info.uk@adinstruments.com info.de@adinstruments.com info.cn@adinstruments.com info.sea@adinstruments.com Germany Japan Australia Indian Subcontinent Asia South America South East Asia International Tel: +81 52 932 6462 Tel: +61 2 8818 3400 Tel: +91 93 1225 2800 Tel: +56 2 356 6749 Tel: +61 2 8818 3400 Fax: +81 52 932 6755 Fax: +61 2 8818 3499 Fax: +91 11 2766 2591 Fax: +56 2 356 6786 Fax: +61 2 8818 3499 info.jp@adinstruments.com info.au@adinstruments.com info.in@adinstruments.com info.cl@adinstruments.com info.au@adinstruments.com