HPR2XX - power, Murata

advertisement
3.0 WATT
MINIATURE SIP DC/DC CONVERTER
Product Data Sheet
HPR2XX
FEATURES
Four Channels Of Isolated Power
High Output Power Density: > 9. 4 Watts/Inch3
Extended Temperature Range:
-25°C To +85°C
High Efficiency: To 84%
Low Cost
High Isolation Voltage: 750V Continuous
Input-to-Output and Channel-to-Channel
Single In-line Package (SIP)
Internal Input and Output Filtering
Non-Conductive Case
The HPR2XX Series is designed for multiple channel applications
that require small size and could benefit from a complete onepackage solution. The HPR2XX Series offers four isolated
channels of output power in a footprint less than the size of many
singular devices. This unregulated series of DC/DC converters
provides three watts of total output power. Each isolated channel
can supply up to 750mW.
or "aliasing" in multiple channel applications.
The HPR2XX Series uses advanced circuit design and packaging
technology to realize superior reliability and performance. With
only one switching converter on the board, the HPR2XX eliminates
the possibility of separate converters creating beat frequencies,
The HPR2XX Series offers the user low cost without sacrificing
reliability. The use of surface mounted devices and manufacturing
technologies make it possible to offer premium performance
and low cost.
The high efficiency of the HPR2XX Series means less internal
power dissipation than comparable solutions. With reduced
heat to dissipate, the HPR2XX Series can operate at higher
temperatures with no degradation in reliablility. In addition, the
high efficiency of the HPR2XX Series provides greater than 9
watts/inch3 output power density.
MECHANICAL
PIN CONNECTIONS
2.210+.010
(56.13)
TOP
VIEW
0.340+.010
(8.64)
1. -VOUT1 5.-VOUT2
9. +VIN
14. -VOUT3
18. -VOUT4
2. COM 1 6. COM2
10.-VIN
15. COM3
19. COM 4
16. +VOUT3
20. +VOUT4
3 +VOUT1 7.+VOUT2
0.340+.010
(8.64)
FRONT
VIEW
RIGHT
SIDE
VIEW
0.400+.010
(10.16)
0.030+.010
(0.76)
0.140+.020
(0.25)
0.010+.002
(0.25)
0.020+.002
(0.51)
0.155+.015
(3.94)
0.050+.015
(1.27)
All dimensions are in inches (millimeters).
GRID: 0.100 inches (2.54 millimeters)
PIN PLACEMENT TOLERANCE: ± 0.015"
Marked with: specific model ordered, date code, and job code.
BOTTOM
VIEW
1 2 3
HPR2XX REV E MPS 12/08
5 6 7
9 10
14 15 16
18 19 20
Page 1
ELECTRICAL SPECIFICATIONS
NOMINAL
RATED
INPUT
VOLTAGE
RATED
OUTPUT
VOLTAGE
INPUT CURRENT
OUTPUT
CURRENT
NO LOAD
REFLECTED
RIPPLE
RATED LOAD
CURRENT
FICIENCY
MODEL
(VDC)
(VDC)
(mA)
(mA)
(mA)
(mAp-p)
(%)
HPR203
HPR204
HPR205
5
5
5
±5.2
±12
±15
±73
±30
±25
70
75
75
820
750
750
35
35
35
74
80
80
HPR210
HPR211
12
12
±12
±15
±30
±25
30
30
305
300
15
15
82
84
HPR216
HPR217
15
15
±12
±15
±30
±25
20
20
240
240
15
20
83
84
HPR221
HPR223
24
24
±5.0
±15
±75
±25
20
20
170
155
20
20
74
81
MIN
TYP
MAX
UNITS
4.5
10.8
13.5
21.6
5
12
15
24
5.5
13.2
16.5
26.4
1
VDC
VDC
VDC
VDC
V/μsec
Amps
Note: Other input to output voltage options may be available. Please consult factory.
COMMON SPECIFICATIONS
Specifications typical at TA = +25°C, nominal input voltage, rated output current unless otherwise specified.
PARAMETER
CONDITIONS
INPUT
Voltage Range
Voltage Rise Time
In Rush Current
ISOLATION
Rated Voltage
Test Voltage
Resistance
Capacitance
Leakage Current
OUTPUT
Total Rated Power
Rated Power Each Channel
Voltage Setpoint Accuracy
Ripple & Noise
Voltage
At Startup
Input to Output, Channel to Channel
60 Hz, 10 seconds
750
750
10
30
4
VISO= 240VAC, 60Hz
3
750
GENERAL
Switching Frequency
Package Weight
Frequency Change
MTTF per MIL-HDBK-217, Rev. E
Ground Benign
Fixed Ground
Naval Sheltered
Airborne Uninhabited Fighter
Internal Power Dissipation............................................................................1.2W
Short Circuit Protection.......................................................................< 1 second
Page 2
%/%VIN
%
%
300
7
5
20
kHz
g
%
%
1.8
450
270
45
MHr
kHr
kHr
kHr
8
17
20
Rated Load to 1mA Load
High Line to Low Line
Circuit Stress Method
TA = +25°C
TA = +35°C
TA = +35°C
TA = +35°C
ABSOLUTE MAXIMUM RATINGS
1
10
3
40
7
High Line to Low Line
Rated Load to 1mA Load
Rated Load to 1mA Load
TEMPERATURE
Specification
Operation
Storage
.05
W
mW
%
mVp-p
mVrms
VDC
VDC
VDC
%/Deg C
±5
Rated Load, Nominal VIN
BW = DC to 10MHz
BW =10Hz to 2MHz
IL=1mA, VOUT = 5V
IL=1mA, VOUT = 12V
IL=1mA, VOUT = 15V
Temperature Coefficent
REGULATION
Line Regulation
Load Regulation (5V out only)
Load Regulation (All other Models)
VDC
Vpk
G7
pF
μArms
-25
-40
-40
+25
ORDERING INFORMATION
Device Family
HPR Indicates DC/DC Converter
Model Number
Selected From Table Above
Screening Option
+85
+100
+110
°C
°C
°C
HPR 2XX /H
HPR2XX REV E MPS 12/08
EF-
420
375
390
High
Line
360
Nominal
Line
325
330
4.75
5.0
5.25 5.5
0
Channel 2-4
6.2
13.4
VOUT (VDC)
14.0
5.0
Channel 1
.75
1.5
2.25
0
3.0
6
12
18
Pout (Watts)
Input Channel 1 (mA)
LOAD REGULATION
LOAD REGULATION
26
VOUT (VDC)
LOAD REGULATION
6.6
5.4
29.5
29.0
Vin (VDC)
5.8
30.0
Low
Line
300
4.5
12.8
12.2
11.6
0
20
40
60
80
0
8
16
24
32
-0
Iout (mA sum of all Outputs)
Iout (mA sum of all Outputs)
REFLECTED RIPPLE CURRENT vs. Pout
50.0
EFFICIENCY vs OUTPUT POWER
90.0
+15Vout
+12Vout
Efficiency (Pout/Pin)
37.5
25.0
12.5
0
67.5
+5Vout
45.0
22.5
0
0
0.8
1.7
2.6
3.4
0
.85
Pout (Watts)
1.7
2.6
3.5
Pout (Watts)
6.25
12.50 18.75
25
Iout (mA sum of all Outputs)
LINE REGULATION
12
Change from Nom Vout (%)
VOUT (VDC)
30.5
+VOUT (VDC)
350
300
Reflected Ripple Current (mA p-p)
CROSS REGULATION HPR205
31.0
400
Frequency (kHZ)
Frequency (kHZ)
TYPICAL PERFORMANCE CURVES
6
0
-6
-12
-10
-5
0
5
10
Pout (Watts)
The information provided herein is believed to be reliable; however, MuraTA POWER SOLUTIONS assumes no responsibility for inaccuracies or omissions. MuraTA POWER SOLUTIONS assumes
no responsibility for the use of this information, and all use of such information shall be entirely at the user’s own risk. Prices and specifications are subject to change without notice. No patent rights
or licenses to any of the circuits described herein are implied or granted to any third party. MuraTA POWER SOLUTIONS does not authorize or warrant any MuraTA POWER SOLUTIONS product for
use in life support devices/systems or in aircraft control applications.
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356
USA:
Mansfield (MA), Tel: (508) 339 3000, email: sales@murata-ps.com
Canada:
Toronto, Tel: (866) 740 1232, email: toronto@murata-ps.com
UK:
Milton Keynes, Tel: +44 (0)1908 615232, email: mk@murata-ps.com
France:
Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: france@murata-ps.com
Germany: München, Tel: +49 (0)89-544334-0, email: ped.munich@murata-ps.com
Japan:
Tokyo, Tel: 3-3779-1031, email: sales_tokyo@murata-ps.com
Osaka, Tel: 6-6354-2025, email: sales_osaka@murata-ps.com
China:
Shanghai, Tel: +86 215 027 3678, email: shanghai@murata-ps.com
Guangzhou, Tel: +86 208 221 8066, email: guangzhou@murata-ps.com
www.murata-ps.com email: sales@murata-ps.com ISO 9001 & ISO 14001 REGISTERED
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2008 Murata Power Solutions, Inc.
HPR2XX REV E MPS 12/08
Singapore: Parkway Centre, Tel: +65 6348 9096, email: singapore@murata-ps.com
Page 3