Table of contents 1/2 Magnetic ballasts Ballasts for fluorescent T8 lamps 230V 50Hz 240V 50Hz 220V 50Hz Ballasts for compact fluorescent lamps 230V 50Hz 240V 50Hz 220V 50Hz 1. 1.1 1.4 1.6 2. 2.1 2.4 2.6 Ballasts fo UV suntanning lamps 3. 230/240V 50Hz 3.1 Ballasts for High Pressure Mercury lamps 230V 50Hz 240V 50Hz 230, 240V 50Hz 220/230/240V 50Hz Ballasts for High Pressure Sodium lamps 230V 50Hz 230/240V 50Hz 220/230/240V 50Hz Ballasts for Metal Halide lamps 230/240V 50Hz Electronic superimposed pulse ignitors Without timer With timer Helvar ignitors for HPS & HI lamps 4. 4.1 4.2 4.3 4.4 5. 5.1 5.2 5.3 6. 6.1 7. 7.1 7.2 7.3 Electronic ballasts Electronic ballasts for fluorescent T5 lamps Standard Cotrollable Digital Electronic ballasts for fluorescent T8 lamps Standard Controllable Electronic ballasts for compact fluorescent lamps Standard Controllable Help 8. 8.1 8.2 8.3 9. 9.1 9.2 10. 10.1 10.2 Table of contents 2/2 Wiring diagrams of magnetic ballasts For fluorescent T8 and UV lamps For compact fluorescent lamps For High Pressure Mercury lamps For High Pressure Sodium lamps For Metal Halide lamps L N 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Wiring diagrams for electronic ballasts For fluorescent T8 lamps For compact fluorescent lamps For fluorescent T5 lamps Dimensions of magnetic ballasts Ballasts for T8, compact & UV lamps Ballasts for HID lamps Dimensions of electronic ballasts Standard electronic ballasts Controllable electronic ballasts Digital electronic ballasts 11. 11.1 11.2 11.3 11.4 11.5 12. 12.1 12.3 12.5 13. 13.1 13.2 14. 14.1 14.2 14.3 Characteristics of electronic ballasts 15. For T5 lamps For T8 lamps For compact lamps 15.1 15.2 15.3 Magnetic ballasts Electronic ballasts 16.1 16.3 Lamp ballast compatibility & approvals Lamp markings 17.1 17.5 For magnetic ballasts For electronic ballasts 18.1 18.2 Instructions for use 16. Compatibility 17. Packing details Digidim products 18. 19. 19.1 Help 1 Magnetic ballasts for FLUORESCENT T8 LAMPS 15-65W 230V 50Hz • Meets EN60920 & EN60921 requirements • Low harmonics • Low power losses • Correctly trimmed lamp current guaranteed for entire lifetime • 100% quality controlled • Double wire terminals without screws • Small size • Long lifetime • CE marked LAMP INFORMATION T8 (G13) Lamp Wattage Current type Length BALLAST INFORMATION COMPENSATION Ballast type Parallel Ck 230/250V ±10% Mains Current EEI (µF) (A) L 15 TL3 L 15 A-P L 15 A L 30 TL2 L 30 A L 30 A-P L 16 DL L 16 D L 18 TL2 L 18 TL3 L 18 TL4 L 18 TLB2 L 18 A-K L 18 A-S L 20 A L 20 A-P L 18 A-L L 26 TS5 - 100 L 26 TS5 - 105 L 36 TL2 L 36 TL3 L 36 TL4 L 36 TLB2 L 36 A-K L 36 A-S 4.5 4.5 4.5 4.5 4.5 4.5 2.0 2.0 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 0.16 0.16 0.16 0.21 0.21 0.21 0.11 0.11 0.16 0.16 0.16 0.16 0.16 0.16 0.16 0.16 0.16 0.16 0.16 0.26 0.26 0.26 0.26 0.,26 0.26 B1 C C B1 B1 B1 B1 B2 B2 B2 B2 C C C C C - Inductive Temp. rise ind/abn EN 60920 Net weight Circuit Diag. Dimensions λ ∆t (°C) (kg) No. No. 0.30 0.31 0.35 0.45 0.50 0.50 0.43 0.46 0.30 0.30 0.30 0.32 0.34 0.32 0.35 0.35 0.35 0.32 0.32 0.45 0.45 0.45 0.48 0.50 0.55 40/70 50/95 55/80 30/70 55/110 50/125 60/150 65/150 35/60 40/70 45/80 50/95 55/95 50/80 55/95 55/95 75/90 65/100 65/100 35/90 40/90 45/110 50/145 50/145 45/125 0.76 0.56 0.62 0.84 0.62 0.56 0.32 0.32 0.84 0.76 0.65 0.55 0.62 0.67 0.62 0.56 0.52 0.50 0.50 0.84 0.76 0.65 0.57 0.67 0.67 1,2 1,2 1,2 4 4 4 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 4 4 4 4 4 4 3 1 1 3 1 1 8 8 3 3 3 3 1 1 1 1 1 6 7 3 3 3 3 1 1 (W) (A) (mm) 1 x 15 1 x 15 1 x 15 2 x 15 2 x 15 2 x 15 1 x 16 1 x 16 1 x 18 1 x 18 1 x 18 1 x 18 1 x 18 1 x 18 1 x 18 1 x 18 1 x 18 1 x 18 1 x 18 2 x 18 2 x 18 2 x 18 2 x 18 2 x 18 2 x 18 2 x 18 0.31 0.31 0.31 0.33 0.33 0.33 0.20 0.20 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 438 438 438 438 438 438 720 720 590 590 590 590 590 590 590 590 590 590 590 590 590 590 590 590 590 0.37 590 L 40 A-S 4.5 0.26 - 0.55 50/150 0.67 4 1 2 x 18 2 x 18 2 x 18 0.37 0.37 590 590 4.5 4.5 0.26 0.26 - 0.55 0.55 55/140 55/155 0.62 0.56 4 4 1 1 0.37 590 L 40 A-M L 40 A-P L 40 A-L 1) 4.5 0.26 - 0.55 75/160 0.52 4 1 1) Not available for European Union market from May 2002 DATA SUBJECT TO CHANGE WITHOUT NOTICE T10 123 1B 4.12.2001 1.1 Magnetic ballasts for FLUORESCENT T8 LAMPS 15-65W 230V 50Hz LAMP INFORMATION T12 (G13) T8 (G13) T12 (G13) Lamp Wattage Current type Length BALLAST INFORMATION COMPENSATION Ballast type Parallel Ck 230/250V ±10% Mains Current (µF) (A) Induc- Temp. rise tive ind/abn EN 60920 Net weight Circuit Diag. Dimensions λ ∆t (°C) (kg) No. No. - 0.32 0.32 0.32 0.32 0.35 0.35 0.35 0.50 0.49 0.49 0.49 0.55 0.55 0.55 0.55 0.55 0.45 0.50 0.46 35/60 40/70 45/80 50/80 55/95 55/95 75/90 50/145 35/90 40/90 45/110 45/125 50/ 150 55/140 55/155 75/160 35/70 40/80 40/95 0.84 0.76 0.65 0.67 0.62 0.56 0.52 0.67 0.84 0.76 0.65 0.67 0.67 0.62 0.56 0.52 0.76 0.62 0.56 1,2 1,2 1,2 1,2 1,2 1,2 1,2 4 4 4 4 4 4 4 4 4 1,2 1,2 1,2 3 3 3 1 1 1 1 1 3 3 3 1 1 1 1 1 3 1 1 0.21 0.21 0.21 B1 B2 B2 0.45 0.45 0.45 30/70 55/110 50/125 0.84 0.62 0.56 1,2 1,2 1,2 3 1 1 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 0.26 0.26 0.26 0.26 0.26 0.26 0.26 0.26 0.26 0.26 0.26 0.26 0.26 0.26 0.26 0.26 0.26 0.26 0.26 B1 B1 B2 B2 B2 B2 C C C D - 0.43 0.43 0.43 0.45 0.45 0.45 0.50 0.50 0.50 0.50 0.45 0.45 0.45 0.48 0.48 0.48 0.48 0.48 0.48 35/90 40/90 45/110 50/145 50/145 45/125 50/150 55/140 55/155 75/160 35/90 40/90 45/110 50/145 45/125 50/150 55/140 55/155 75/160 0.84 0.76 0.65 0.57 0.67 0.67 0.67 0.62 0.56 0.52 0.84 0.76 0.65 0.67 0.67 0.67 0.62 0.56 0.52 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 3 3 3 3 1 1 1 1 1 1 3 3 3 1 1 1 1 1 1 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 0.26 0.26 0.26 0.26 0.26 0.26 0.26 0.26 - 0.47 0.47 0.47 0.50 0.50 0.50 0.50 0.50 35/90 40/90 45/110 45/125 50/150 55/140 55/155 75/160 0.84 0.76 0.65 0.67 0.67 0.62 0.56 0.52 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 3 3 3 1 1 1 1 1 (W) (A) (mm) 1 x 20 1 x 20 1 x 20 1 x 20 1 x 20 1 x 20 1 x 20 2 x 20 2 x 20 2 x 20 2 x 20 2 x 20 2 x 20 2 x 20 2 x 20 2 x 20 1 x 25 1 x 25 1 x 25 1 X 30 1 X 30 1 X 30 1 X 36 1 X 36 1 X 36 1 X 36 1 X 36 1 X 36 1 X 36 1 X 36 1 X 36 1 X 36 1 X 38 1 X 38 1 X 38 1 X 38 1 X 38 1 X 38 1 X 38 1 X 38 1 X 38 1 X 40 1 X 40 1 X 40 1 X 40 1 X 40 1 X 40 1 X 40 1 X 40 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.29 0.29 0.29 590 590 590 590 590 590 590 590 590 590 590 590 590 590 590 590 970 970 970 L 18 TL2 L 18 TL3 L 18 TL4 L 18 A-S L 20 A L 20 A-P L 18 A-L L 36 A-K L 36 TL2 L 36 TL3 L 36 TL4 L 36 A-S L 40 A-S L 40 A-M L 40 A-P L 40 A-L 1) L 15 TL3 L 15 A L 15 A-P 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 3.5 3.5 3.5 0.16 0.16 0.16 0.16 0.16 0.16 0.16 0.26 0.26 0.26 0.26 0.26 0.26 0.26 0.26 0.26 0.15 0.15 0.15 0.365 0.365 0.365 0.43 0.43 0.43 0.43 0.43 0.43 0.43 0.43 0.43 0.43 0.43 0.43 0.43 0.43 0.43 0.43 0.43 0.43 0.43 0.43 0.43 0.43 0.43 0.43 0.43 0.43 0.43 900 900 900 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1047 1047 1047 1047 1047 1047 1047 1047 1047 1200 1200 1200 1200 1200 1200 1200 1200 L 30 TL2 L 30 A L 30 A-P 4.5 4.5 4.5 L 36 TL2 L 36 TL3 L 36 TL4 L 36 TLB2 L 36 A-K L 36 A-S L 40 A-S L 40 A-M L 40 A-P L 40 A-L 1) L 36 TL2 L 36 TL3 L 36 TL4 L 36 A-K L 36 A-S L 40 A-S L 40 A-M L 40 A-P L 40 A-L 1) L 36 TL2 L 36 TL3 L 36 TL4 L 36 A-S L 40 A-S L 40 A-M L 40 A-P L 40 A-L 1) 1) Tolerance ±2% 2) Not available for European Union market from May 2002 DATA SUBJECT TO CHANGE WITHOUT NOTICE T10 123 1B 4.12.2001 EEI 1.2 Magnetic ballasts for FLUORESCENT T8 LAMPS 15-65W 230V 50Hz LAMP INFORMATION T12 (G13) T8 (G13) Lamp Wattage Current Length type BALLAST INFORMATION COMPENSATION Ballast type Parallel Ck 230/250V ±10% Mains Current (µF) (A) EEI Inductive Temp. rise ind/abn EN 60920 Net weight Circuit Diag. Dimensions λ ∆t (°C) (kg) No. No. (W) (A) (mm) 1 X 42 0.53 1047 L 42 A 6.0 0.26 - 0.45 55/110 1.00 1,2 2 1 X 58 1 X 58 1 X 58 1 X 58 1 X 58 1 X 58 1 X 58 1 X 58 1 X 58 1 X 58 1 X 58 1 X 58 1 X 65 1 X 65 1 X 65 1 X 65 1 X 65 1 X 65 1 X 65 1 X 65 1 X 65 1 X 65 1 X 65 1 X 65 0.67 0.67 0.67 0.67 0.67 0.67 0.67 0.67 0.67 0.67 0.67 0.67 0.67 0.67 0.67 0.67 0.67 0.67 0.67 0.67 0.67 0.67 0.67 0.67 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 L 58 TL2 L 58 TL3 L 58 TLB2 -220mm L 58 TLB2 -180mm L 58 TL4 -220mm L 58 TL4 L 58 A-S L 58 A-K L 65 A-S L 65 A-M L 65 A L 65 A-P L 58 TL2 L 58 TL3 L 58 TL4 -220mm L 58 TL4 L 58 TLB2 -220mm L 58 TLB2 -180mm L 58 A-S L 58 A-K L 65 A-S L 65 A-M L 65 A L 65 A-P 7.0 7.0 7.0 7.0 7.0 7.0 7.0 7.0 7.0 7.0 7.0 7.0 7.0 7.0 7.0 7.0 7.0 7.0 7.0 7.0 7.0 7.0 7.0 7.0 0.35 0.35 0.35 0.35 0.35 0.35 0.35 0.35 0.35 0.35 0.35 0.35 0.35 0.35 0.35 0.35 0.35 0.35 0.35 0.35 0.35 0.35 0.35 0.35 B1 B1 B2 B2 B2 B2 B2 B2 C C C C - 0.45 0.45 0.47 0.47 0.45 0.45 0.48 0.48 0.50 0.50 0.50 0.50 0.45 0.45 0.45 0.45 0.47 0.47 0.48 0.48 0.50 0.50 0.50 0.50 35/95 40/95 50/140 50/140 40/110 40/110 45/130 50/145 50/135 60/140 55/145 55/145 35/95 40/95 40/110 40/110 50/140 50/140 45/130 50/145 50/135 60/140 55/145 55/145 1.41 1.30 0.91 0.90 1.06 1.06 1.05 1.05 1.05 1.05 1.00 0.87 1.41 1.30 1.06 1.06 0.91 0.90 1.05 1.05 1.05 1.05 1.00 0.87 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 4 4 4 5 4 5 2 2 2 2 2 2 4 4 4 5 4 5 2 2 2 2 2 2 DATA SUBJECT TO CHANGE WITHOUT NOTICE T10 123 1B 4.12.2001 1.3 Magnetic ballasts for FLUORESCENT T8 LAMPS 15-125W 240V 50Hz • Meets EN60920 & EN60921 requirements • Low harmonics • Low power losses • Correctly trimmed lamp current guaranteed for entire lifetime • 100% quality controlled • Double wire terminals without screws • Small size • Long lifetime • CE marked LAMP INFORMATION T12 T8 (G13) T12 (G13) T8 (G13) Lamp Wattage type Current Length (W) (A) (mm) 1 x 15 1 x 15 2 x 15 2 x 15 1 x 18 1 x 18 1 x 18 1 x 18 1 x 18 1 x 18 2 x 18 2 x 18 2 x 18 2 x 18 1 x 20 1 x 20 1 x 20 1 x 20 2 x 20 2 x 20 2 x 20 2 x 20 1 x 25 1 x 25 1 x 30 1 x 30 1 x 36 1 x 36 1 x 36 1 x 36 1 x 38 1 x 38 1 x 38 1 x 38 1 x 40 1 x 40 1 x 40 1 x 40 0.31 0.30 0.31 0.31 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.29 0.29 0.365 0.365 0.43 0.43 0.43 0.43 0.43 0.43 0.43 0.43 0.43 0.43 0.43 0.43 438 438 438 438 590 590 590 590 590 590 590 590 590 590 590 590 590 590 590 590 590 590 970 970 900 900 1200 1200 1200 1200 1047 1047 1047 1047 1200 1200 1200 1200 BALLAST INFORMATION COMPENSATION Ballast type L 15 A-P L 15 A L 30 A-P L 30 A L 18 TL2 L 18 TL4 L 20 A L 20 A-P L 26 TS5 -100 L 26 TS5 -105 L 36 TL2 L 36 TL4 L 40 A L 40 A-P L 18 TL2 L 18 TL4 L 20 A L 20 A-P L 36 TL2 L 36 TL4 L 40 A L 40 A-P L 15 A L 15 A-P L 30 A L 30 A-P L 36 TL2 L 36 TL4 L 40 A L 40 A-P L 36 TL2 L 36 TL4 L 40 A L 40 A-P L 36 TL2 L 36 TL4 L 40 A L 40 A-P Parallel Ck 240/250V ±10% Mains Current (µF) (A) 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.5 4.5 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 3.0 3.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 0.11 0.11 0.17 0.17 0.16 0.16 0.13 0.13 0.16 0.16 0.22 0.22 0.23 0.23 0.16 0.16 0.14 0.14 0.22 0.22 0.23 0.23 0.14 0.14 0.17 0.17 0.22 0.22 0.23 0.23 0.22 0.22 0.23 0.23 0.22 0.22 0.23 0.23 DATA SUBJECT TO CHANGE WITHOUT NOTICE T10 124 1B 10.04.2002 1.4 EEI C C C C C C B1 C C - Inductive Temp. rise ind/abn EN 60920 Net weight Circuit DimenDiag. sions λ ∆t (°C) (kg) No. No. 0.31 0.35 0.45 0.45 0.30 0.29 0.35 0.35 0.31 0.31 0.44 0.44 0.53 0.53 0.32 0.31 0.35 0.35 0.48 0.48 0.53 0.53 0.45 0.49 0.45 0.45 0.42 0.42 0.50 0.50 0.44 0.44 0.50 0.52 0.46 0.46 0.50 0.50 60/85 55/90 55/125 55/125 40/65 45/80 60/90 60/90 65/110 65/110 35/95 45/115 55/ 70/160 40/65 45/80 60/90 60/90 35/95 45/115 55/ 70/160 55/90 60/85 55/125 55/125 35/95 45/115 55/ 70/160 35/95 45/115 55/ 70/160 35/95 45/115 55/ 70/160 0.56 0.63 0.56 0.63 0.84 0.65 0.63 0.56 0.50 0.50 0.84 0.65 0.63 0.56 0.84 0.65 0.63 0.56 0.84 0.65 0.63 0.56 0.63 0.56 0.63 0.56 0.84 0.65 0.63 0.56 0.84 0.65 0.63 0.56 0.84 0.65 0.63 0.56 1,2 1,2 4 4 1,2 1,2 1,2 1,2 1,2 1,2 4 4 4 4 1,2 1,2 1,2 1,2 4 4 4 4 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1 1 1 1 3 3 1 1 6 7 3 3 1 1 3 3 1 1 3 3 1 1 1 1 1 1 3 3 1 1 3 3 1 1 3 3 1 1 Magnetic ballasts for FLUORESCENT T8 LAMPS 15-125W 240V 50Hz LAMP INFORMATION T8 (G13) T12 (G13) T8 (G13) Lamp Wattage Current Length type BALLAST INFORMATION COMPENSATION Ballast type Parallel Ck 240/250V ±10% Mains Current (µF) (A) EEI Inductive Net weight λ Temp. rise ind/abn EN 60920 ∆t (°C) Circuit DimenDiag. sions (kg) No. No. 35/95 45/115 60/140 60/145 60/145 1.41 1.06 1.12 1.00 0.90 1,2 1,2 1,2 1,2 1,2 4 4 2 2 2 (W) (A) (mm) 1 x 58 1 x 58 1 x 58 1 x 58 1 x 58 0.67 0.67 0.67 0.67 0.67 1500 1500 1500 1500 1500 L 58 TL2 L 58 TL4 L 65 A-S L 65 A L 65 A-P 7.0 7.0 7.0 7.0 7.0 0.35 0.35 0.31 0.31 0.31 B1 B2 C C C 0.42 0.42 0.45 0.50 0.50 1 x 65 0.67 1500 L 58 TL2 7.0 0.35 - 0.42 35/95 1.41 1,2 4 1 x 65 0.67 1500 L 58 TL4 7.0 0.35 - 0.42 45/115 1.06 1,2 4 1 x 65 0.67 1500 L 65 A-S 7.0 0.31 - 0.45 60/140 1.12 1,2 2 1 x 65 0.67 1500 L 65 A 7.0 0.31 - 0.50 60 1.00 1,2 2 1 x 65 1 x 70 1 x 70 1 x 70 1 X 75 1 x 85 1 X 100 1 X 100 1 X 125 1 X 125 0.67 0.70 0.70 0.70 0.67 0.80 0.96 0.96 0.94 0.94 1500 1800 1800 1800 1800 1800 2400 2400 2400 2400 L 65 A-P L 75 A-S L 75 A L 70 TL4 L 70 TL4 L 85 A-S L100 TE61 L100 TE8 L100 TE61 L100 TE8 7.0 6.0 6.0 6.0 6.0 8.0 10.0 10.0 0.31 0.41 0.41 0.40 0.40 0.43 0.55 0.55 - C B2 - 0.50 0.55 0.55 0.50 0.54 0.55 0.52 0.50 2) 0.62c 2) 0.60c 60/145 60 65 45 45 65 55/145 75/190 55/145 75/190 0.90 1.12 1.00 1.32 1.32 1.12 1.32 1.32 1.32 1.32 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 3 3 2 2 2 5 5 2 4 4 4 4 1) 1) - 1) Essential: Series capacitor 7.2µF ±4% 440V 2) Capacitive DATA SUBJECT TO CHANGE WITHOUT NOTICE T10 124 1B 10.04.2002 1.5 Magnetic ballasts for FLUORESCENT T8 LAMPS 15-65W 220V 50Hz • Meets EN60920 & EN60921 requirements • Low harmonics • Low power losses • Correctly trimmed lamp current guaranteed for entire lifetime • 100% quality controlled • Double wire terminals without screws • Small size • Long lifetime • CE marked LAMP INFORMATION T12 T8 T12 T8 (G13) T12 (G13) T8 (G13) Lamp Wattage type BALLAST INFORMATION COMPENSATION Parallel Ck 240/250V ±10% Mains Current Power Losses (µF) (A) 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 3.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 7.0 2) 5.7 L 58 TL2 7.0 L 65 A 5.7 Current Length (W) (A) (mm) 1 x 15 2 x 15 1 x 18 1 x 18 1 x 18 2 x 18 2 x 18 2 x 18 1 x 20 1 x 20 1 x 20 2 x 20 2 x 20 2 x 20 1 x 25 1 x 30 1 x 36 1 x 36 1 x 36 1 x 38 1 x 38 1 x 38 1 x 40 1 x 40 1 x 40 1 x 58 1 x 58 0.31 0.31 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.29 0.36 0.43 0.43 0.43 0.43 0.43 0.43 0.43 0.43 0.43 0.67 0.67 438 438 590 590 590 590 590 590 590 590 590 590 590 590 970 900 1200 1200 1200 1047 1047 1047 1200 1200 1200 1500 1500 L 15A-P L 30A-P L 18 TL2 L 20A-P L 18 A-L L 36 TL2 L 40 A-P 3) L 40 A-L 1 x 65 0.67 1500 1 x 65 0.67 1500 Ballast type L 18 TL2 L 20 A-P L 18 A-L L 36 TL2 L 40 A-P 3) L 40 A-L L 15 A-P L 30 A-P L 36 TL2 L 40 A-P 3) L 40 A-L L 36 TL2 L 40 A-P 3) L 40 A-L L 36 TL2 L 40 A-P 3) L 40 A-L L 58 TL2 L 65 A 2) 1) Winding at 25°C 2) Tolerance ±4 % 3) Not available for European Union market from May 2002 DATA SUBJECT TO CHANGE WITHOUT NOTICE T10 121 1B 10.04.2002 1.6 Inductive Temp. rise ind/abn EN 60920 Net weight Circuit Diag. Dimensions (W) λ ∆t (°C) (kg) No. No. 0.16 0.21 0.16 0.16 0.16 0.26 0.27 0.27 0.16 0.16 0.16 0.26 0.27 0.27 0.15 0.21 0.26 0.27 0.27 0.26 0.27 0.27 0.26 0.27 0.27 0.35 0.34 8.2 7.5 5.5 9.0 9.3 5.5 9.2 9.5 5.5 9.0 9.3 5.5 9.2 9.5 6.7 7.5 5.5 9.2 9.5 5.5 9.2 9.5 5.5 9.2 9.5 8 12 0.35 0.50 0.30 0.35 0.35 0.49 0.53 0.55 0.32 0.35 0.35 0.49 0.55 0.55 0.50 0.50 0.43 0.50 0.50 0.45 0.49 0.49 0.47 0.50 0.50 0.47 0.50 50/85 45/110 35/50 55/85 65/90 35/90 55/155 65/160 35/50 55/85 65/90 35/90 55/155 65/160 50/85 45/110 35/90 55/155 65/160 35/90 55/155 65/160 35/90 55/155 65/160 35/95 55/140 0.56 0.56 0.76 0.56 0.52 0.76 0.56 0.52 0.76 0.56 0.52 0.76 0.56 0.52 0.56 0.56 0.76 0.56 0.52 0.76 0.56 0.52 0.76 0.56 0.52 1.30 1.30 1,2 4 1,2 1,2 1,2 4 4 4 1,2 1,2 1,2 4 4 4 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1,2 1 1 3 1 1 3 1 1 3 1 1 3 1 1 1 1 3 1 1 3 1 1 3 1 1 4 2 0.35 8 0.47 35/95 1.30 1,2 4 0.34 12 0.50 55/140 1.00 1,2 2 1) 2 Magnetic ballasts for COMPACT FLUORESCENT & T5 LAMPS 4-36W 230V 50Hz • Meets EN60920 & EN60921 requirements • Low power losses • 100% quality controlled • Double wire terminals without screws • Low harmonics • Very low magnetic field • Small size • Long lifetime • CE marked LAMP INFORMATION TC-S ( G23) T5 ( G5) Lamp Wattage Current Length type (W) (A) (mm) 1x4 1x4 2x4 2x4 1x6 1x6 2x6 2x6 2x6 1x8 1x8 1x8 2x8 2x8 2x8 1 x 13 1 x 13 1 x 13 1x5 1x5 2x5 2x5 2x5 1x7 1x7 2x7 2x7 2x7 1x9 1x9 2x9 2x9 2x9 1 x 11 1 x 11 0.17 0.17 0.17 0.17 0.16 0.16 0.16 0.16 0.16 0.145 0.145 0.145 0.145 0.145 0.147 0.165 0.165 0.165 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.17 0.17 0.17 0.17 0.17 0.155 0.155 136 136 136 136 212 212 212 212 212 288 288 288 288 288 288 517 517 517 105 105 105 105 105 135 135 135 135 135 170 170 170 170 170 240 240 BALLAST INFORMATION COMPENSATION Ballast type L8 DL L8 D L8 DL L8 D L8 DL L8 D L13 TL2 -100mm L 13 DL L 13 D L8 DL L8 D L11 D L13 DL L16 DL L16 D L13 TL2 -100mm L 13 DL L 13 D L11 DL L11 D L13 TL2 -100mm L 13 DL L 13 D L11 DL L11 D L13 TL2 -100mm L 13 DL L 13 D L11 DL L11 D L13 TL2 -100mm L 13 DL L 13 D L11 DL L11 D Parallel Ck 230/250V ±10% Mains Current (µF) (A) 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 0.06 0.06 0.06 0.06 0.06 0.06 0.08 0.10 0.10 0.06 0.06 0.06 0.10 0.11 0.11 0.08 0.10 0.10 0.07 0.07 0.08 0.10 0.10 0.07 0.07 0.08 0.10 0.10 0.07 0.07 0.09 0.10 0.10 0.08 0.08 DATA SUBJECT TO CHANGE WITHOUT NOTICE T10 130 1B 10.04.2002 2.1 EEI - Inductive Temp. rise ind/abn EN60920 Net weight Circuit Diag. Dimensions λ ∆t (°C) (kg) No. No. 0.25 0.25 0.35 0.35 0.30 0.30 0.41 0.45 0.45 0.35 0.33 0.33 0.50 0.43 0.50 0.43 0.45 0.45 0.28 0.25 0.36 0.35 0.40 0.30 0.28 0.46 0.45 0.45 0.32 0.33 0.56 0.55 0.55 0.43 0.43 55/95 65/90 55/95 65/90 55/95 65/90 30/40 50/95 65/120 55/95 65/90 60/85 50/95 60/150 65/150 30/40 50/95 65/120 60/95 60/85 30/40 50/95 65/120 60/95 60/85 30/40 50/95 65/120 60/95 60/85 30/40 50/95 65/120 60/95 60/85 0.32 0.32 0.32 0.32 0.32 0.32 0.5 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.5 0.32 0.32 0.32 0.32 0.5 0.32 0.32 0.32 0.32 0.5 0.32 0.32 0.32 0.32 0.5 0.32 0.32 0.32 0.32 7 7 8 8 7 7 8 8 8 7 7 7 8 8 8 7 7 7 9 9 11 11 11 9 9 11 11 11 9 9 11 11 11 9 9 8 8 8 8 8 8 6 8 8 8 8 8 8 8 8 6 8 8 8 8 6 8 8 8 8 6 8 8 8 8 6 8 8 8 8 Magnetic ballasts for COMPACT FLUORESCENT & T5 LAMPS 4-36W 230V 50Hz LAMP INFORMATION TC-L ( 2G11) Lamp Wattage Current Length type (W) (A) (mm) 1 x 18 1 x 18 1 x 18 1 x 18 1 x 18 1 x 18 1 x 18 1 x 18 1 x 18 1 x 18 2 x 18 2 x 18 2 x 18 2 x 18 2 x 18 2 x 18 2 x 18 2 x 18 2 x 18 2 x 18 1 x 24 1 x 24 1 x 24 1 x 24 1 x 24 1 x 24 1 x 24 1 X 24 1 X 24 1 x 24 1 X 36 1 X 36 1 X 36 1 X 36 1 X 36 1 X 36 1 X 36 1 X 36 1 X 36 1 X 36 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.34 0.34 0.345 0.345 0.34 0.34 0.34 0.345 0.345 0.34 0.43 0.43 0.43 0.43 0.43 0.43 0.43 0.43 0.43 0.43 225 225 225 225 225 225 225 225 225 225 225 225 225 225 225 225 225 225 225 225 320 320 320 320 320 320 320 320 320 320 415 415 415 415 415 415 415 415 415 415 BALLAST INFORMATION COMPENSATION Ballast type L18 TL2 L18 TL3 L18 TL4 L18 TLB2 L18 A-S L20 A L20 A-P L26 TS5 -100mm L26 TS5 -105mm L18 A-L L36 A-K L36 TL2 L36 TL3 L36 TL4 L36 TLB2 L36 A-S L40 A-S L40 A-M L40 A-P L40 A-L L18 TL2 L18 TL3 L18 TL4 L18 TLB2 L18 A-S L20 A L20 A-P L26 TS5 -100mm L26 TS5 -105mm L18 A-L L36 TL2 L36 TL3 L36 TL4 L36 TLB2 L36 A-K L36 A-S L40 A-S L40 A-M L40 A-P L40 A-L Parallel Ck 230/250V ±10% Mains Current (µF) (A) 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 4.5 0.16 0.16 0.16 0.16 0.16 0.16 0.16 0.16 0.16 0.16 0.26 0.26 0.26 0.26 0.26 0.26 0.26 0.26 0.26 0.26 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.18 0.26 0.26 0.26 0.26 0.26 0.26 0.26 0.26 0.26 0.26 DATA SUBJECT TO CHANGE WITHOUT NOTICE T10 130 1B 10.04.2002 2.2 EEI B1 B1 B2 B2 B2 C C C C B1 B1 B1 B2 B2 B2 B2 B2 B2 C B1 B1 B2 B2 B2 B2 C C C D Induc- Temp. rise tive ind/abn EN 60920 Net weight Circuit Diag. Dimensions λ ∆t (°C) (kg) No. No. 0.30 0.30 0.30 0.32 0.32 0.35 0.35 0.32 0.32 0.35 0.50 0.45 0.45 0.45 0.48 0.50 0.55 0.55 0.55 0.55 0.38 0.38 0.41 0.41 0.40 0.42 0.42 0.40 0.40 0.42 0.43 0.43 0.43 0.45 0.45 0.50 0.50 0.50 0.50 0.50 35/60 40/70 45/80 50/95 50/80 55/95 55/95 65/100 65/100 75/90 50/145 35/90 40/90 45/110 50/145 45/125 50/150 55/140 55/155 75/160 35/60 40/70 45/80 50/95 50/80 55/95 55/95 65/100 65/100 75/90 35/90 40/90 45/110 50/145 50/145 45/125 50/150 55/140 55/155 75/160 0.84 0.76 0.65 0.55 0.67 0.62 0.56 0.50 0.50 0.52 0.67 0.84 0.76 0.65 0.57 0.67 0.67 0.62 0.56 0.52 0.84 0.76 0.65 0.55 0.67 0.62 0.56 0.50 0.50 0.52 0.84 0.76 0.65 0.57 0.67 0.67 0.67 0.62 0.56 0.52 10 10 10 10 10 10 10 10 10 10 12 12 12 12 12 12 12 12 12 12 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 3 3 3 3 1 1 1 6 7 1 1 3 3 3 3 1 1 1 1 1 3 3 3 3 1 1 1 6 7 1 3 3 3 3 1 1 1 1 1 1 Magnetic ballasts for COMPACT FLUORESCENT & T5 LAMPS 4-36W 230V 50Hz LAMP INFORMATION Lamp Wattage Current Length type (A) Ballast type (mm) Parallel Ck 230/250V ±10% Mains Current (µF) (A) EEI Induc- Temp. rise tive ind/abn EN 60920 Net weight Circuit Diag. Dimensions λ ∆t (°C) (kg) No. No. 1 x 16 0.20 140 L16 DL 2.0 0.11 - 0.43 60/150 0.32 13 8 1 x 16 1 x 21 0.20 0.26 140 140 L16 D L21 TL2 -100mm 2.0 3.0 0.11 0.16 B2 B1 0.46 0.40 65/150 40/70 0.32 0.5 13 13 8 6 1 x 28 0.325 205 L18 TL2 3.5 0.20 - 0.48 35/60 0.84 13 3 1 x 28 0.325 205 L18 TL3 3.5 0.20 - 0.48 40/70 0.76 13 3 1 x 28 0.32 205 L18 TL4 3.5 0.20 - 0.44 45/80 0.65 13 3 1 x 28 0.325 205 L18 TLB2 3.5 0.20 B2 0.48 50/95 0.55 13 3 1 x 28 0.32 205 L18 A-S 3.5 0.20 B2 0.48 50/80 0.67 13 1 1 x 28 0.325 205 L20 A 3.5 0.20 - 0.50 55/95 0.62 13 1 0.32 205 L20 A-P 3.5 0.20 - 0.50 55/95 0.56 13 1 1 x 28 0.325 205 L18 A-L 3.5 0.20 C 0.50 75/90 0.52 13 1 1 x 22 0.40 220ø L30 TL2 5.0 0.21 - 0.30 220ø L30 A 5.0 0.21 - 0.35 0.84 0.62 3 0.40 40/70 60/110 13a 1 x 22 13a 1 1 x 32 0.45 312ø L32 A 5.0 0.23 - 0.40 55/120 0.62 13a 1 1 x 10 1 x 10 1 x 10 0.19 110 L 13 TL2 -100mm 0.19 0.19 110 110 L13 DL L13 D 2.0 2.0 2.0 0.08 0.08 0.08 B1 B2 B2 0.31 0.35 0.35 30/40 50/95 65/120 0.5 0.32 0.32 9 9 9 6 8 8 1 x 13 1 x 13 1 x 13 1 x 18 1 x 18 1 x 18 1 x 26 1 x 26 1 x 26 1 x 26 1 x 26 1 x 26 1 x 26 1 x 26 0.175 0.175 0.175 0.22 0.22 0.22 0.31 0.31 0.325 0.31 0.31 0.31 0.31 0.325 140 140 140 160 160 160 193 193 193 193 193 193 193 193 L 13 TL2 -100mm L13 DL L13 D L18 TLD-100mm L18 DL L18 D L18 TL2 L18 TL3 L18 TL4 L18 TLB2 L18 A-S L20 A 2.0 2.0 2.0 2.0 2.0 2.0 3.5 3.5 3.5 3.5 3.5 3.5 0.08 0.10 0.10 0.12 0.14 0.14 0.18 0.18 0.18 0.18 0.18 0.18 A3 B1 B1 B1 B1 B1 B2 B2 - 0.43 0.45 0.45 0.45 0.45 0.50 0.43 0.43 0.45 0.45 0.43 0.45 30/40 50/95 65/120 30/60 60/150 65/155 35/60 40/70 45/80 50/95 50/80 55/95 0.5 0.32 0.32 0.5 0.32 0.32 0.84 0.76 0.65 0.55 0.67 0.62 9 9 9 9 9 9 9 9 9 9 9 9 6 8 8 6 8 8 3 3 3 3 1 1 L20 A-P L26 TS5 -100mm 3.5 3.5 0.18 0.18 B2 B2 0.45 0.45 55/95 65/100 0.56 0.50 9 9 1 6 1 x 26 0.325 193 L26 TS5 -105mm 3.5 0.18 B2 0.45 65/100 0.50 9 6 1 x 26 0.31 193 L18 A-L 3.5 0.18 C 0.45 75/90 0.52 9 1 TC-D ( G 24 d) 1) 1 x 28 T-R TC-DD ( GR 8) 2) (W) BALLAST INFORMATION COMPENSATION 1) Cap G10q 2) Also GR 10q; external starter required DATA SUBJECT TO CHANGE WITHOUT NOTICE T10 130 1B 10.04.2002 2.3 Magnetic ballasts for COMPACT FLUORESCENT & T5 LAMPS 4-36W 240V 50Hz • Meets EN60920 & EN60921 requirements • Low power losses • 100% quality controlled • Double wire terminals without screws • Low harmonics • Very low magnetic field • Small size • Long lifetime • CE marked LAMP INFORMATION TC-L (2 G11) TC-D (G24d) TC-S (G23) T5 (G5) Lamp Wattage Current Length type (W) (A) (mm) 1x4 2x4 1x6 2x6 1x8 1x8 2x8 1x13 1x5 2x5 1x7 2x7 1x9 2x9 1x11 1x16 0.17 0.17 0.16 0.16 0.145 0.145 0.175 0.165 0.18 0.18 0.18 0.18 0.17 0.17 0.155 0.2 136 136 212 212 288 288 288 517 105 105 135 135 170 170 240 720 BALLAST INFORMATION COMPENSATION Ballast type L8D L8D L8D L 13 D L8D L 11 D L 16 D L 13 D L 11 D L 13 D L 11 D L 13 D L 11 D L 13 D L 11 D L 16 D Parallel Ck 240/250V ±10% Mains Current EEI Inductive (µF) (A) 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 0.06 0.06 0.06 0.10 0.06 0.06 0.11 0.10 0.07 0.10 0.07 0.10 0.07 0.10 0.08 0.11 B2 Temp. rise ind/abn EN 60920 Net weight Circuit Diag. Dimensions λ ∆t (°C) (kg) No. No. 0.25 0.35 0.30 0.45 0.33 0.33 0.45 0.45 0.25 0.40 0.30 0.45 0.33 0.55 0.43 0.45 60/90 60/90 60/90 65/110 60/90 65/90 65/90 65/110 65/90 65/110 65/90 65/110 65/90 65/110 65/90 65/90 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 7 8 7 8 7 7 8 7 9 11 9 11 9 11 9 9 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 1x10 0.19 110 L 13 D 2.0 0.08 C 0.35 65/110 0.32 9 8 1x13 1x18 1x26 1x26 1x26 1x26 1x26 1x26 1x18 1x18 1x18 1x18 1x18 1x18 2x18 2x18 2x18 2x18 0.175 0.22 0.31 0.31 0.31 0.31 0.325 0.325 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 0.37 140 160 193 193 193 193 193 193 225 225 225 225 225 225 225 225 225 225 L 13 D L 18 D L 18 TL2 L 18 TL4 L 20 A L 20 A-P L 26 TS5 -100 L 26 TS5 -105 L 18 TL2 L 18 TL4 L 20 A L 20 A-P L 26 TS5 -100 L 26 TS5 -105 L 36 TL2 L 36 TL4 L 40 A L 40 A-P 2.0 2.0 3.5 3.5 3.0 3.0 3.5 3.5 4.0 4.0 4.0 4.0 4.5 4.5 4.0 4.0 4.0 4.0 0.10 0.14 0.18 0.18 0.17 0.17 0.18 0.18 0.16 0.16 0.13 0.13 0.16 0.16 0.22 0.22 0.23 0.23 B2 B1 - 0.45 0.45 0.43 0.42 0.45 0.45 0.43 0.43 0.30 0.29 0.35 0.35 0.31 0.31 0.44 0.44 0.53 0.53 65/110 65/160 40/65 45/80 60/90 60/90 50/110 50/110 40/65 45/80 60/90 60/90 65/110 65/110 35/95 45/115 55/ 70/160 0.32 0.32 0.84 0.65 0.63 0.56 0.50 0.50 0.84 0.65 0.63 0.56 0.50 0.50 0.84 0.65 0.63 0.56 9 9 9 9 9 9 9 9 10 10 10 10 10 10 12 12 12 12 8 8 3 3 1 1 6 7 3 3 1 1 6 7 3 3 1 1 DATA SUBJECT TO CHANGE WITHOUT NOTICE T10 131 1B 10.04.2002 2.4 Magnetic ballasts for COMPACT FLUORESCENT & T5 LAMPS 4-36W 240V 50Hz LAMP INFORMATION T-R 2) TC-DD 1) TC-L ( 2 G11) Lamp Wattage Current Length type BALLAST INFORMATION COMPENSATION Ballast type Parallel Ck 240/250V ±10% Mains Current (µF) (A) EEI Inductive Temp. rise ind/abn EN 60920 Net weight Circuit DimenDiag. sions λ ∆t (°C) (kg) No. No. (W) (A) (mm) 1 x 24 1 x 24 1 x 24 1 x 24 1 x 24 1 x 24 1 x 36 1 x 36 1 x 36 1 x 36 1 x 16 1 x 28 1 x 28 1 x 28 1 x 28 0.34 0.34 0.34 0.34 0.345 0.345 0.43 0.43 0.43 0.43 0.195 0.325 0.325 0.325 0.325 320 320 320 320 320 320 415 415 415 415 140 205 205 205 205 L 18 TL2 L 18 TL4 L 20 A L 20 A-P L 26 TS5 -100 L 26 TS5 -105 L 36 TL2 L 36 TL4 L 40 A L 40 A-P L 16 D L 18 TL2 L 18 TL4 L 20 A L 20 A-P 3.5 3.5 3.5 3.5 4.0 4.0 4.0 4.0 4.0 4.0 2.0 3.5 3.5 3.0 3.0 0.18 0.18 0.16 0.16 0.18 0.18 0.22 0.22 0.23 0.23 0.11 0.20 0.20 0.19 0.19 B2 - 0.48 0.47 0.42 0.42 0.38 0.38 0.42 0.42 0.52 0.50 0.45 0.48 0.47 0.50 0.50 40/65 45/80 60/90 60/90 55/110 55/110 35/95 45/115 55/ 70/ 65/160 40/65 45/80 60/90 60/90 0.84 0.65 0.63 0.56 0.50 0.50 0.84 0.65 0.63 0.56 0.32 0.84 0.65 0.63 0.56 10 10 10 10 10 10 10 10 10 10 13 13 13 13 13 3 3 1 1 6 7 3 3 1 1 8 3 3 1 1 1 x 22 1 x 32 0.40 0.45 220ø 312ø L 30 A L 32 A 5.0 4.0 0.21 0.18 - 0.35 0.40 60/125 65/140 0.63 0.63 13a 13a 1 1 1) Cap GR8 (also GR 10q); external starter required 2) Cap G10q DATA SUBJECT TO CHANGE WITHOUT NOTICE T10 131 1B 10.04.2002 2.5 Magnetic ballasts for COMPACT FLUORESCENT & T5 LAMPS 5-36W 220V 50Hz • Meets EN60920 & EN60921 requirements • Low power losses • 100% quality controlled • Double wire terminals without screws • Low harmonics • Very low magnetic field • Small size • Long lifetime • CE marked LAMP INFORMATION Lamp Wattage Current Length type (W) (A) BALLAST INFORMATION COMPENSATION Ballast type (mm) TC-D (G24d) TC-S (G23) T5 (G5) 0.16 212 L 13 D 0.145 288 L 11 D 0.175 288 L 16 D 0.165 517 L 13 D 0.20 720 L 16 D 0.18 105 L 11 D 0.18 105 L 13 D 0.18 135 L 11 D 0.18 135 L 13 D 0.17 170 L 11 D 0.14 170 L 13 D 0.155 240 L 11 D 0.19 110 L 13 D 0.175 140 L 13 D 1 x 18 0.22 160 L 18 D 1 x 26 0.31 193 L 18 TL2 1 x 26 0.31 193 L 20 A-P 1 x 26 0.31 193 L 18 A-L 1 x 18 0.375 225 L 18 TL2 1 x 18 0.37 225 L 20 A-P 1 x 18 0.37 225 L 18 A-L 2 x 18 0.37 225 L 36 TL2 2 x 18 0.37 225 L 40 A-P 2 x 18 0.37 225 L 40 A-L 1 x 24 0.34 320 L 18 TL2 1 x 24 0.34 320 L 20 A-P 1 x 24 0.34 320 L 18 A-L 1 x 36 0.435 415 L 36 TL2 1 x 36 0.43 415 L 40 A-P 1 x 36 0.43 415 L 40 A-L 1 x 16 0.20 140 L 16 D 1 x 28 0.325 205 L 18 TL2 1 x 28 0.325 205 L 20 A-P 1 x 28 0.325 205 L 18 A-L 1) Winding at 25°C 2) Gap GR8, also GR 10q; external starter required TC-DD 2) TC-L (2G11) 2x6 1x8 2x8 1 x 13 1 x 16 1x5 2x5 1x7 2x7 1x9 2x9 1 x 11 1 x 10 1 x 13 Parallel Ck 240/250V ±10% Mains Current Power Losses (µF) (A) 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 3.5 3.5 3.5 4.5 4.5 4.5 4.5 4.5 4.5 4.0 4.0 4.0 4.5 4.5 4.5 2.0 3.5 3.5 3.5 0.10 0.06 0.11 0.10 0.11 0.07 0.10 0.07 0.10 0.07 0.10 0.08 0.08 0.10 0.14 0.18 0.18 0.18 0.16 0.16 0.16 0.26 0.27 0.27 0.18 0.18 0.18 0.26 0.27 0.27 0.11 0.20 0.20 0.20 DATA SUBJECT TO CHANGE WITHOUT NOTICE T10 125 1B 10.04.2002 2.6 Inductive Temp. rise ind/abn EN 60920 Net weight (W) λ ∆t (°C) (kg) No. No. 5.0 3.8 4.8 4.6 5.3 5.0 5.0 5.0 5.0 4.5 4.1 3.7 5.6 4.3 5.6 6.0 9.0 9.3 6.0 9.0 9.3 6.0 9.2 9.5 5.0 9.0 9.3 6.0 9.2 9.5 5.3 6.0 9.0 9.3 0.45 0.35 0.52 0.45 0.48 0.25 0.40 0.30 0.45 0.35 0.55 0.45 0.35 0.45 0.50 0.43 0.46 0.46 0.30 0.35 0.35 0.49 0.52 0.52 0.38 0.43 0.43 0.43 0.50 0.50 0.48 0.48 0.50 0.50 65/110 60/85 65/150 65/110 65/110 60/85 65/110 60/85 65/110 60/85 65/110 60/85 65/110 65/110 65/155 35/50 55/85 65/90 35/50 55/85 65/90 35/90 55/155 65/160 35/50 55/85 65/90 35/90 55/155 65/160 65/110 35/50 55/85 65/90 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.32 0.76 0.56 0.52 0.76 0.56 0.52 0.76 0.56 0.52 0.76 0.56 0.52 0.76 0.56 0.52 0.32 0.76 0.56 0.52 8 7 8 7 7 9 11 9 11 9 11 9 9 9 9 9 9 9 10 10 10 12 12 12 10 10 10 10 10 10 13 13 13 13 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 3 1 1 3 1 1 3 1 1 3 1 1 3 1 1 8 3 1 1 1) Circuit DimenDiag. sions 3 Magnetic ballasts for UV SUNTANNING LAMPS 80-160W 230, 240V 50Hz • Low power losses • Low harmonics • 100% quality controlled • Very low magnetic field • Long lifetime • Low noise • Recyclable materials • ’Automatic’ earthing • CE marked 230V LAMP INFORMATION T8 (G13) Lamp Wattage Current Length type (W) (A) (mm) 80 85 100 100 100 140 160 0.87 0.80 1.00 1.00 1.00 1.50 1.50 1500 1800 1800 1800 1800 1500 1800 BALLAST INFORMATION COMPENSATION Ballast type L 80 A-S L 85 T6 L 100 T7 L 100 T9 L 100 T9 -180 L 140 T9 L 160 EN Voltage Parallel Ck 240/250V ±10% 230 230 230 230 230 230 230 240V LAMP INFORMATION Lamp Wattage Current Length type T8 (W) (A) Mains Current Inductive Temp. rise ind/abn EN 60920 Net weight Circuit Diag. Dimensions (µF) (A) λ ∆t (°C) (kg) No. No. 8.0 8.0 10.0 10.0 10.0 18.0 14.0 0.47 0.45 0.55 0.55 0.55 0.77 0.77 0.50 0.55 0.50 0.50 0.50 0.50 0.52 70/170 55/160 60/145 70/190 70/190 80/190 60/150 1.01 1.01 1.32 1.10 1.07 1.50 2.00 1,2 1,2 1,2 1,2 1,2 1,2 5 2 5 4 4 5 4 9 BALLAST INFORMATION COMPENSATION Ballast type Voltage Parallel Ck 240/250V ±10% (mm) (µF) Mains Current Inductive Temp. rise ind/abn EN 60920 Net weight Circuit Diag. Dimensions (A) λ ∆t (°C) (kg) No. No. 85 0.80 1800 L 85 T6 240 8.0 0.45 0.50 55/ - 1.07 1,2 5 100 1.00 1800 L 100 T7 240 10.0 0.55 0.50 60/ - 1.32 1,2 4 100 1.00 1800 L 100 T9 240 10.0 0.55 0.50 70/ - 1.11 1,2 4 DATA SUBJECT TO CHANGE WITHOUT NOTICE T10 129 1B 10.04.2002 3.1 4 Magnetic ballasts for HIGH PRESSURE MERCURY LAMPS 50-400W 230V 50Hz • Meets EN60922 & EN60923 requirements • Very low magnetic field • 100% quality controlled • Low power losses • Low harmonics • Low noise • Long lifetime • Multiple fixing point variations • CE marked LAMP INFORMATION HM Lamp type Wattage Current (W) (A) 50 50 80 80 125 125 250 250 400 0.62 0.62 0.80 0.80 1.15 1.15 2.15 2.15 3.25 BALLAST INFORMATION COMPENSATION Ballast type Parallel Ck 230/250V ±10% Mains Current Power losses (µF) (A) 7.0 7.0 8.0 8.0 10.0 10.0 18.0 18.0 25.0 0.30 0.30 0.45 0.45 0.70 0.70 1.40 1.40 2.15 E 50 LU E 50 T7 E 80 LU E 80 T7 E 125 LU E 125 T7 E 250 EN 2) E 250 T,F 2) E 400 T,F 1) Winding at 25°C 2) T-type = two and four point fixing F-type = four point fixing DATA SUBJECT TO CHANGE WITHOUT NOTICE T11 028 2A 23.10.2001 4.1 Inductive Temp. rise EN 60922 Net weight Circuit Diag. Dimensions (W) λ ∆t (°C) (kg) No. No. 11.0 11.4 12.0 13.5 13.7 15.3 20.0 22.0 25.4 0.40 0.46 0.50 0.52 0.55 0.56 0.55 0.55 0.60 60 65 65 70 70 70 75 65 65 1.22 0.71 1.22 0.93 1.22 1.34 2.0 2.20 3.16 14 23 14 23 14 23 19 17 17 20 11 20 12 20 13 24 14,17 15,18 1) Magnetic ballasts for HIGH PRESSURE MERCURY LAMPS 50-400W 240V 50Hz • Meets EN60922 & EN60923 requirements • Very low magnetic field • 100% quality controlled • Low power losses • Low harmonics • Low noise • Long lifetime • Multiple fixing point variations • CE marked LAMP INFORMATION HM Lamp type W attage Current (W) (A) 50 80 125 250 250 400 0.62 0.80 1.15 2.15 2.15 3.25 BALLAST INFORMATION COMPENSATION Ballast type Parallel Ck 230/250V ±10% Mains Current Power losses (µF) (A) 7.0 8.0 10.0 18.0 18.0 25.0 0.30 0.45 0.70 1.40 1.40 2.15 E 50 LU E 80 LU E 125 LU E 250 EN 2) E 250 T,F 2) E 400 T,F 1) Winding at 25°C 2) T-type = two and four point fixing F-type = four point fixing DATA SUBJECT TO CHANGE WITHOUT NOTICE T11 029 1A 23.10.2001 4.2 Inductive Temp. rise EN 60922 Net weight Circuit Diag. Dimensions (W) λ ∆t (°C) (kg) No. No. 11.3 12.4 13.5 20.5 23.0 26.6 0.40 0.50 0.55 0.55 0.55 0.60 70 70 70 75 70 70 1.22 1.22 1.22 2.0 2.20 3.16 14 14 14 16 18 18 20 20 20 24 14,17 15,18 1) Magnetic ballasts for HIGH PRESSURE MERCURY LAMPS with two lamp wattages 80/50W - 125/80W 230, 240V 50Hz • Meets EN60922 & EN60923 requirements • Very low magnetic field • 100% quality controlled • Low power losses • Low harmonics • Low noise • Long lifetime • Multiple fixing point variations • CE marked 230V / 50Hz ballasts LAMP INFORMATION HM Lamp Wattage type BALLAST INFORMATION COMPENSATION Current Ballast type Voltage Parallel Ck 230/250V ±10% Power losses Inductive (µF) (A) (W)1) λ (W) (A) 80/50 0.80/0.62 E 80/50 LU 230 8.0 0.45/0.30 125/80 1.15/0.80 E 125/80 LU 230 10.0 0.70/0.45 240V / 50Hz ballasts LAMP INFORMATION Lamp Wattage type HM Mains Current Temp. rise Net Circuit DimenEN 60922 weight Diag. sions ∆t (°C) (kg) No. No. 12.8/10.0 0.50/0.42 65/55 1.22 15 20 14.5/11.5 0.55/0.50 70/60 1.22 15 20 BALLAST INFORMATION COMPENSATION Current Ballast type Voltage Parallel Ck 230/250V ±10% Mains Current Power losses Inductive (µF) (A) (W)1) λ (W) (A) 80/50 0.80/0.62 E 80/50 LU 240 8.0 0.45/0.30 125/80 1.15/0.80 E 125/80 LU 240 10.0 0.70/0.45 Temp. rise Net Circuit DimenEN 60922 weight Diag. sions ∆t (°C) (kg) No. No. 13.3/10.5 0.50/0.42 65/55 1.22 15 20 15.0/12.0 0.55/0.50 70/60 1.22 15 20 230/240V / 50Hz ballasts LAMP INFORMATION HM Lamp Wattage type Current (W) (A) 125/80 1.15/0.80 BALLAST INFORMATION COMPENSATION Ballast type E 125/80 ENK Voltage Parallel Ck 230/250V ±10% 230/240 Power losses Inductive (µF) (A) (W)1) λ ∆t (°C) (kg) No. No. 10.0/8.0 0.70/0.45 14.0/9.5 0.55/0.50 60 1.5 20 23 1) Winding at 25°C DATA SUBJECT TO CHANGE WITHOUT NOTICE T11 030 1A 23.10.2001 Temp. rise Net Circuit DimenEN 60922 weight Diag. sions Mains Current 4.3 Magnetic ballasts for HIGH PRESSURE MERCURY LAMPS 50 - 400W 220 / 230 / 240V 50Hz • Meets EN60922 & EN60923 requirements • Very low magnetic field • 100% quality controlled • Low power losses • Low harmonics • Low noise • Long lifetime • Multiple fixing point variations • CE marked LAMP INFORMATION Mains Current Power losses Inductive (µF) (A) (W)1) λ ∆t (°C) (kg) No. No. 220 230 240 7.0 0.3 11.0 11.3 11.6 0.42 70 1.22 21 20 E 80 LU 220 230 240 8.0 0.45 12.0 12.4 12.8 0.50 70 1.22 21 20 1.15 E 125 LU 220 230 240 10.0 0.7 13.5 14.0 14.7 0.55 70 1.22 21 20 250 2.15 E 250 EN 220 230 240 18.0 1.4 21.0 0.55 75 2.00 24 24 250 2.15 E 250 T,F2) 220 230 240 18.0 1.4 1.4 1.3 20.0 21.0 22.0 0.55 60 65 70 2.20 22 14,17 400 3.25 E 400 T,F2) 220 230 240 25.0 2.15 24.0 25.0 26.0 0.60 60 65 70 3.16 22 15,18 Wattage Current Ballast type (W) (A) 50 0.61 E 50 LU 80 0.80 125 HM Lamp type BALLAST INFORMATION COMPENSATION Voltage Parallel Ck 230/250V ±10% 1) Winding at 25°C 2) T-type = two and four point fixing F-type = four point fixing DATA SUBJECT TO CHANGE WITHOUT NOTICE T11 031 1A 23.10.2001 4.4 Temp. rise Net Circuit DimenEN 60922 weight Diag. sions 5 Magnetic ballasts for HIGH PRESSURE SODIUM LAMPS 35 -70W 230V 50Hz • Meets EN60922 & EN60923 requirements • Small size • Double wire terminals without screws • 100% quality controlled • Long lifetime • Very low magnetic field • Low harmonics • Low power losses • CE marked LAMP INFORMATION Lamp Wattage type Current BALLAST INFORMATION COMPENSATION Ballast type Voltage Parallel Ck 230/250V ±10% Mains Current Power losses Inductive Temp. rise Net Circuit DimenEN 60922 weight Diag. sions (µF) (A) (W)1) λ ∆t (°C) (kg) No. No. (A) 35 0.53 NK 35 T62) 230 6.0 0.27 10.5 0.39 65 0.63 28 10 70 1.00 NK 70 T7 2) 230 12.0 0.43 16.0 0.39 70 1.15 28 12 HS (W) 1) Winding at 25°C 2) For metal halide and HPS lamps (no thermal protector fitted) DATA SUBJECT TO CHANGE WITHOUT NOTICE T11 033 1A 23.10.2001 5.1 Magnetic ballasts for HIGH PRESSURE SODIUM LAMPS 35 - 1000W 230 / 240V 50Hz • Meets EN60922 & EN60923 requirements • Very low magnetic field • 100% quality controlled • Low power losses • Low harmonics • Low noise • Long lifetime • Multiple fixing point variations • CE marked LAMP INFORMATION HS Lamp type BALLAST INFORMATION COMPENSATION W attage Current (W) (A) 35 0.49 NK 35 LUS3) 50 0.75 NK 50 LUS4) 50 0.75 NK 50 LU7) 70 1.0 NK 70 ENK7) 70 0.98 NK 70 LUK7) 70 1.0 NK 70 LU7) 70/50 1.0/0.75 NK 70/50 LU 70/50 1.0/0.75 NK 70/50 LUP 100 1.35 NK 100 LUS5) 100 1.2 NK 100 EN7) 100 1.2 NK 100 LU7) 100/70 1.2/1.0 NK 100/70 ENK 100/70 1.2/1.0 NK 100/70 EN 150 1.8 Ballast type 7) NK 150 ENK7) 150 1.8 NK 150/2 LU2)7) 150 1.8 NK 150 T,F6)7) 150 1.8 NK 150 EN7) 150/100 1.8/1.2 NK150/100 EN 250 3.0 NK 250 T,F6)7) 400 4.4 NK 400 T,F6)7) 1000 10.3 NK 1000 EI Voltage Parallel Ck 230/250V ±10% 230 240 230 240 230 240 230 240 230 240 230 240 230 240 230 230 240 230 240 230 240 230 240 230 240 230 240 230 240 230 240 230 240 230 240 230 240 230 240 230 240 Mains Current Power losses Inductive (µF) (A) (W)1) λ 6.0 0.27 8.0 0.33 8.0 0.33 12.0 0.43 12.0 0.43 12.0 0.43 12.0/8.0 0.43/0.33 12.0/8.0 0.43/0.33 16.0 0.60 12.0 0.56 12.0 0.56 12.0 0.56/0.43 12.0 0.56/0.43 20.0 1.1 20.0 1.1 1.0 20.0 1.1 20.0 1.1 20.0/12.0 1.1/0.56 32.0 1.4 50 2.2 100 5.3 5.0 1) Winding at 25°C 2) Type NK 150/2 LU contains two ballasts of the same type 3) For Philips SDW-T 35 W lamps (Ignitor CSL 35) 4) For Philips SDW-T 50 W lamps (Ignitor CSL 50) DATA SUBJECT TO CHANGE WITHOUT NOTICE T11 034 1A 23.10.2001 Temp. rise Net Circuit DimenEN 60922 weight Diag. sions ∆t (°C) (kg) No. No. 50 1.22 - 20 50 1.22 - 20 70 1.22 26 20 60 1.5 30 23 65 1.22 26 20 70 1.22 26 20 75/60 1.22 27 20 75/60 1.22 27 20 80 1.22 - 20 65 1.5 30 23 80 1.22 26 20 13.5/11.2 0.40/0.36 55/50 2.0 35 23 15.0/12.0 0.40/0.37 70/60 1.5 35 23 0.42 60 2.2 30 25 0.42 70 2.45 34 20 0.42 70 75 2.17 29 14,17 0.42 75 2.0 30 24 0.42/0.39 75/60 2.6 35 24 3.15 29 15,18 4.3 29 16,19 10.0 32 21 9.0 0.38 9.4 9.8 0.40 10.0 12.0 0.38 12.5 12.0 0.38 12.5 13.5 0.39 14.0 14.8 0.39 15.0 14.5/11.0 0.39/0.38 15.0/11.5 14.5/11.0 0.39/0.38 15.0/11.5 16.5 0.40 17.0 14.0 0.43 14.6 15.6 0.44 16.6 16.5 17.4 29.0 30.0 20.0 21.0 17.5 19.5 21/13 28 29 32 33 55 59 0.42 0.40 0.43 70 75 70 75 80 5) For Philips SDW-T 100 W lamps (Ignitor CSL 100) 6) T-type = two and four point fixing F-type = four point fixing 7) These ballasts can also be delivered with thermal protector. In these cases the product type will be e.g NK 70 LUP 230/240V 5.2 Magnetic ballasts for HIGH PRESSURE SODIUM LAMPS 50 - 400W 220 / 230 / 240V 50Hz • Meets EN60922 & EN60923 requirements • Very low magnetic field • 100% quality controlled • Low power losses • Low harmonics • Low noise • Long lifetime • Multiple fixing point variations • CE marked LAMP INFORMATION HS Lamp type BALLAST INFORMATION COMPENSATION Parallel Ck 230/250V ±10% Mains Current Power losses Inductive Temp. rise EN 60922 (µF) (A) (W)1) λ ∆t (°C) (kg) No. No. 220 230 240 8.0 0.33 11.5 12.0 12.5 0.38 70 1.22 31 20 220 230 240 12.0 0.43 14.5 14.8 15.0 0.39 70 1.22 31 20 2) 220 230 240 20.0 1.1 19.0 20.0 21.0 0.42 70 70 75 2.17 33 14,17 3.0 NK 250 T,F 2) 220 230 240 32.0 1.4 27 28 29 0.42 70 70 75 3.15 33 15,18 4.4 NK 400 T,F 2) 220 230 240 50 2.2 31 32 33 0.40 70 70 75 4.3 33 16,19 W attage Current Ballast type (W) (A) 50 0.76 NK 50 LU 70 1.0 NK 70 LU 150 1.8 NK 150 T,F 250 400 Voltage 1) Winding at 25°C 2) T-type = two and four point fixing F-type = four point fixing DATA SUBJECT TO CHANGE WITHOUT NOTICE T11 035 1A 23.10.2001 5.3 Net Circuit Dimenweight Diag. sions 6 Magnetic ballasts for METAL HALIDE LAMPS 35 - 1000W 230 / 240V 50Hz • Meets EN60922 & EN60923 requirements • Very low magnetic field • 100% quality controlled • Low power losses • Low harmonics • Low noise • Long lifetime • Multiple fixing point variations • CE marked LAMP INFORMATION HI Lamp Wattage type Current BALLAST INFORMATION COMPENSATION Ballast type Voltage Parallel Ck 230/250V ±10% Mains Current Power losses (µF) (A) (W) λ ∆t (°C) (kg) No. No. 1) Induc- tive Temp. rise Net EN 60922 weight Circuit DimenDiag. sions (W) (A) 35 0.53 NK 35 LUP 3) 230 240 6.0 0.27 9.0 9.4 0.38 50 1.22 39 20 35 0.53 NK 35 T6 230 6.0 0.27 10.5 0.39 65 0.63 42 10 70/50 1.0/0.75 NK 70/50 LUP 230 12.0/8.0 0.43/0.33 75/60 1.22 37b 20 70 1.0 NK70 ENPK 12.0 0.43 60 1.5 38 23 70 0.98 NK 70 LUPK 12.0 0.43 65 1.22 37a 20 70 1.0 NK 70 LUP 12.0 0.43 70 1.22 37a 20 70 1.00 NK 70 T7 12.0 0.43 0.39 70 1.15 42 12 100 1.2 NK 100 ENP 12.0 0.56 0.42 65 1.5 38 23 100 1.1 NK 100 LUP 12.0 0.56 0.44 80 1.22 37a 20 150 1.8 NK 150 ENPK 20.0 1.1 2.2 38 25 150 1.8 NK 150 TP, FP 20.0 1.1 2.17 41 14,17 150 1.8 NK 150 ENP 20.0 1.1 2.0 38 24 250 3.0 NK 250 TP,FP 32.0 1.4 3.15 41 15,18 3.18 40 15,17 400 3.5 H 400 T,F 2)4) 400 3.5 E 400 T,F 2)4) 1000 9.5 H 1000 EI 230 240 230 240 230 240 230 230 240 230 240 230 240 230 240 230 240 230 240 230 240 230 240 230 240 35 2.2 35 2.15 100 4.6 1) Winding at 25°C 2) T-type = two and four point fixing F-type = four point fixing 3) No thermal protector inside 4) Available with thermal switch DATA SUBJECT TO CHANGE WITHOUT NOTICE T11 037 1A 25.7.2002 6.1 14.5/11.0 0.39/0.38 15.0/11.5 12.0 0.38 12.5 13.5 0.39 14.0 14.8 0.39 15.0 16.0 14.0 14.6 15.6 16.6 16.5 17.4 20 21 17.5 18.5 28 29 24.9 26 25 26 56 60 0.50 0.48 60 65 70 75 75 80 70 75 70 75 0.60 80 3.16 40 15,17 0.47 75 10.0 43 21 0.40 0.42 0.42 0.42 7 ELECTRONIC SUPERIMPOSED PULSE IGNITORS WITHOUT TIMER 220-240V 50/60Hz • Fully electronic • Super-imposed pulse type • Compact design • Solid metal fixing screw • Low inherent heating • High thermal resistance • Low power losses • ENEC approved • CE marked Light source: L-70 L-150 HI-400S L-1000 HS lamps (W) 35-70 100-150 100-400 100-1000 HI lamps (W) - 35-150 70-400 70-1000 Max. contin. lamp current (A) 1 1.8 4.6 12 Operating voltage (V) 198-264 198-264 198-264 198-264 Cut-out voltage (V) ≤ 170 ≤ 170 ≤ 170 ≤ 170 Ignition voltage (kV) 1.9 ... 2.3 4.0 ... 4.5 4.0 ... 4.5 4.0 ... 4.5 Impulse width (µs) 2 (1.5 kV) 1.4 (2.0 kV) 1.0 (2.0 kV) 1.7 (2.5 kV) Phasing (°el) 60-90 / 240-270 60-90 / 240-270 60-90 / 240-270 60-90 / 240-270 2 3 3 3 Pulses per half cycle Max. load capacitance (pF) 200 100 100 100 Internal losses (W) < 1.0 (25°C; 1A) < 1.0 (25°C; 1.8A) < 3.3 (25°C; 4.6A) < 6.0 (25°C; 12A) Max. housing temperature (°C) 105 105 105 105 Min. ambient temperature (°C) -30 -30 -30 -30 Weight (g) 105 128 150 450 Dimensions AxBxC (mm) 88x34x28 88x34x28 92x39x33 108x55x43 Terminals: 3-pole B-Lp-N 2.5 mm 2 max L1 C D M8 L B 10 Ignitor A N DATA SUBJECT TO CHANGE WITHOUT NOTICE T17 007 1A 23.10.2001 7.1 N ELECTRONIC SUPERIMPOSED PULSE IGNITORS WITH TIMER 220-240V 50/60Hz • Fully electronic • Super-imposed pulse type • Compact design • Solid metal fixing screw • Low inherent heating • High thermal resistance • Low power losses • ENEC approved • CE marked LSI-150T20 LHI-400ST10 LSI-1000T10 (W) 35-70 LSI-70T1 100-150 100-400 100-1000 (W) - 35-150 70-400 70-1000 1 1.8 4.6 12 Cut out time (min) 2 20 16 18 Operating voltage (V) 198-264 198-264 198-264 198-264 Cut-out voltage (V) ≤ 170 ≤ 170 ≤ 170 ≤ 170 Ignition voltage (kV) 1.9 ... 2.3 4.0 ... 4.5 3.5 ... 4.5 4.0 ... 4.5 Impulse width (µs) 2 (1.5 kV) 1.4 (2.0 kV) 1.0 (2.0 kV) 1.7 (2.5 kV) Phasing (°el) 60-90 / 240-270 60-90 / 240-270 60-90 / 240-270 60-90 / 240-270 3 3 3 Light source: HS lamps HI lamps Max. contin. lamp current (A) Pulses per half cycle 2 Max. load capacitance (pF) 200 100 100 100 Internal losses (W) <1.0 (25°C; 1A) <1.0 (25°C;1.8A) <3.0 (25°C; 4.6A) <6.0 (25°C; 12A) Max. housing temp. (°C) 105 105 105 105 Min. ambient temp. (°C) -30 -30 -30 -30 Weight (g) 128 184 450 Dimensions AxBxC (mm) 88x34x28 88x34x28 92x39x33 108x55x43 105 Terminals: 3-pole B-Lp-N 2.5 mm 2 max L1 C D M8 L B 10 Ignitor A N DATA SUBJECT TO CHANGE WITHOUT NOTICE T17 008 1A 23.10.2001 7.2 N HELVAR IGNITORS FOR HIGH PRESSURE SODIUM- AND METAL HALIDE LAMPS HIGH PRESSURE SODIUM Ignitor Watt 35 50 70 100 150 250 400 1000 CERAMIC METAL HALIDE 35 L-70 LSI-70T1 L-150 LSI-150T20 HI-400S LHI-400ST10 L-1000 LSI-1000T10 Recommended combination T1 T10 T20 Automatic cut-out 2 min Automatic cut-out 18 min Automatic cut-out 20 min DATA SUBJECT TO CHANGE WITHOUT NOTICE T17 006 1B 13.6.2002 7.3 70 100 150 METAL HALIDE 35 70 100 150 250 400 1000 8 Electronic ballasts for FLUORESCENT T5 LAMPS 14-54W Standard 220-240V 50-60Hz • 21 or 28 mm high • Optimal lamp operation • Wide operational ambient temperature range • Flickerless light • Low power losses • Silent operation • Stabilized output • Low harmonics • High power factor Lamp type W 14 21 T5 24 28 35 39 49 54 80 No. of lamps Ballast 1 1 2 2 3 3 4 4 1 1 2 2 1 1 2 2 1 1 2 2 1 1 2 2 1 1 2 2 1 1 2 2 1 1 2 2 EL 1x14-35s EL 1x14 HFT5 EL 2x14-35s EL 2x14 HFT5 EL 3/4x14s EL 3x14 HFT5 EL 3/4x14s EL 4x14 HFT5 EL 1x14-35s EL 1x21 HFT5 EL 2x14-35s EL 2x21 HFT5 EL 1x24s EL 1x24 HFT5 EL 2x24s EL 2x24 HFT5 EL 1x14-35s EL 1x28 HFT5 EL 2x14-35s EL 2x28 HFT5 EL 1x14-35s EL 1x35 HFT5 EL 2x14-35s EL 2x35 HFT5 EL 1x39s EL 1x39 HFT5 EL 2x39s EL 2x39 HFT5 EL 1x49s EL 1x49 HFT5 EL 2x49s EL 2x49 HFT5 EL 1x54s EL 1x54 HFT5 EL 2x54s EL 2x54 HFT5 1 EL 1x80s Circuit power Mains current (W) (A) (kHz) 16 17 31 32 47 50 62 64 23 24 45 46 25 26 49 51 30.5 31 60 63 38 38 76 80 42 42 84 82 53 54 105 105 58 59 116 115 0.08-0.07 0.08-0.07 0.15-0.13 0.16-0.15 0.22-0.19 0.23-0.20 0.29-0.26 0.29-0.26 0.11-0.10 0.11-0.10 0.20-0.18 0.21-0.20 0.13-0.12 0.14-0.12 0.24-0.21 0.24-0.21 0.14-0.13 0.15-0.13 0.27-0.25 0.28-0.27 0.18-0.16 0.18-0.16 0.34-0.31 0.35-0.34 0.20-0.18 0.20-0.18 0.36-0.33 0.36-0.33 0.25-0.23 0.25-0.23 0.50-0.46 0.50-0.46 0.26-0.24 0.26-0.24 0.53-0.48 0.53-0.49 46 29 46 27 46 28 46 28 46 26 46 36 59 26 59 29 46 25 46 32 46 26 46 32 53 24 53 24 27 26 27 25 42 25 42 25 85 0.37-0.34 45 DATA SUBJECT TO CHANGE WITHOUT NOTICE T07 067 1B 4.12.2001 8.1 Operating EEI frequency Lamp power Weight Wiring Dimensions (W) (g) no. no. A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 14 14 14 14 14 14 14 14 21 21 21 21 22.5 24 22.5 24 28 28 28 28 35 35 35 35 39 39 39 39 49 49 49 49 54 54 54 54 215 270 285 340 285 400 285 400 215 270 285 340 215 270 285 340 215 270 285 340 215 270 285 340 215 270 285 340 215 270 285 340 215 270 285 340 64 64 65 65 66b 66a 67 67 64 64 65 65 64 64 65 65 64 64 65 65 64 64 65 65 64 64 65 65 64 64 65 65 64 64 65 65 29 26 30 27 30 28 30 28 29 26 30 27 29 26 30 27 29 26 30 27 29 26 30 27 29 26 30 27 29 26 30 27 29 26 30 27 A2 80 215 64 29 Electronic ballasts for FLUORESCENT T5 LAMPS 28-35W Controllable 220-240V 50-60Hz • Dimming range 3-100% • Energy saving • Starting at any dimmed level without flicker • Low weight • Flickerless light • Covers EMC requirements • Low harmonics • Stabilized output • 28 mm high T5 Lamp type W 28 35 No. of lamps 1 2 1 2 Ballast Circuit power Mains current (W) (A) (kHz) 33 63 40 78 0.15-0.13 0.29-0.28 0.19-0.17 0.36-0.33 45 - 75 45 - 75 45 - 75 45 - 75 EL 1x28 HFCT5 EL 2x28 HFCT5 EL 1x35 HFCT5 * EL 2x35 HFCT5 * * Dimming range 15-100% if Ta < 20°C DATA SUBJECT TO CHANGE WITHOUT NOTICE T07 068 1A 1.11.2001 8.2 Operating EEI frequency A1 A1 A1 A1 Lamp power Weight Wiring Dimensions (W) (g) no. no. 28 28 35 35 320 400 320 400 68 69 68 69 34 35 34 35 Electronic ballasts for FLUORESCENT T5 LAMPS 28-35W • Digital 220-240V 50-60Hz protocol • Microprocessor controlled • Dimming range 3-100% • Low weight • Flickerless light • Energy saving • Stabilized output • Starting at any dimmed level without flicker • 28 mm high T5 Lamp type W 28 35 No. of lamps 1 2 1 2 Ballast Circuit power Mains current (W) (A) (kHz) 33 63 40 78 0.16-0.14 0.29-0.27 0.19-0.17 0.36-0.33 > 45 > 45 > 45 > 45 EL 1x28 HFIT5 EL 2x28 HFIT5 EL 1x35 HFIT5 * EL 2x35 HFIT5 * * Dimming range 15-100% if Ta < 20°C DATA SUBJECT TO CHANGE WITHOUT NOTICE T07 069 1B 10.12.2001 8.3 Operating EEI frequency A1 A1 A1 A1 Lamp power Weigth Wiring Dimensions (W) (g) no. no. 28 28 35 35 320 400 320 400 70 71 70 71 36 37 36 37 9 Electronic ballasts for FLUORESCENT T8 LAMPS 18-70W Standard 220-240V 50-60Hz • Energy saving • Warm Start according to lamp standards • Low weight • Flickerless light • Covers EMC requirements • Low harmonics • Low power losses • Stabilized output • 28 mm high Lamp type W T8 18 32 36 58 70 No. of lamps 1 2 3 4 2 1 2 1 2 1 2 Ballast EL 1x18 HF EL 2x18 HF EL 3x18 HF EL 4x18 HF EL 2x32 HF EL 1x36 HF 1) EL 2x36 HF 1) EL 1x58 HF 1) EL 2x58 HF 1) EL 1x70 HF EL 2x70 HF Circuit power (W) Mains current (A) 19 36 55 74 73 36 70 56 108 66 133 0.09-0.08 0.16-0.15 0.26-0.24 0.34-0.31 0.34-0.31 0.16-0.15 0.32-0.29 0.26-0.23 0.49-0.45 0.29-0.28 0.59-0.54 1) Also available with side mounted case DATA SUBJECT TO CHANGE WITHOUT NOTICE T07 063 1A 22.10.2001 9.1 Operating EEI frequency (kHz) 26 27 30 30 23 26 60 27 44 27 27 A2 A2 A3 A3 A3 A3 A3 A3 A3 A3 Lamp power (W) Weight Wiring (g) no. Dimensions no. 16 16 16 16 32 32 32 50 50 60 60 270 340 400 400 340 270 340 270 340 270 340 45 46 47 48 46 45 46 45 46 45 46 26 27 28 28 27 26 27 26 27 26 27 Electronic ballasts for FLUORESCENT T8 LAMPS 18-70W Controllable 230-240V 50-60Hz • Dimming range 5-100% • Energy saving • Starting at any dimmed level without flicker • Low weight • Flickerless light • Covers EMC requirements • Low harmonics • Stabilized output • 28mm high Lamp type W No. of lamps T8 18 36 58 70 1 2 1 2 1 2 1 Ballast EL 1x18 HFC EL 2x18 HFC EL 1x36 HFC EL 2x36 HFC EL 1x58 HFC EL 2x58 HFC * EL 1x70 HFC Circuit power Mains current (W) (A) (kHz) 20 38 38 72 58 113 68 0.10-0.08 0.19-0.17 0.18-0.16 0.35-0.31 0.27-0.25 0.56-0.50 0.32-0.29 32-70 34-62 40-70 30-60 40-70 30-80 30-70 * 220-240V 50-60Hz DATA SUBJECT TO CHANGE WITHOUT NOTICE T07 065 1A 22.10.2001 9.2 Operating EEI frequency A1 A1 A1 A1 A1 A1 A1 Lamp power Weight Wiring Dimensions (W) (g) no. no. 16 16 32 32 50 50 60 320 400 320 400 320 400 320 49 50 49 50 49 50 49 34 35 34 35 34 35 34 10 Electronic ballasts for COMPACT LAMPS 9-55W Standard 220-240V 50-60Hz • Energy saving • Warm start according to lamp standards • Low weight • Flickerless light • Covers EMC requirements • Low harmonics • Low power losses • Stabilized output • Low earth leakage current Lamp type W No. of lamps 18 TC-L 24 34 36 40 55 TC-F 18 24 36 TC-DE 10 13 18 26 1 2 1 2 1 2 1 1 2 1 1 2 1 2 1 1 2 1 2 1 1 2 2 1 2 1 2 1 2 1 2 Ballast EL 1x18-42 CHF EL 2x18-40 CHF EL 1x18-42 CHF EL 2x18-40 CHF EL 1x36 HF EL 2x36 HF2F* EL 1x18-42 CHF EL 1x36 HF EL 2x36 HF2F* EL 1x18-42 CHF EL 1x36 HF EL 2x36 HF2F* EL 1x55 HF2F EL 2x55 HF2F* EL 1x18 HF EL 1x18-42 CHF EL 2x18-40 CHF EL 1x18-42 CHF EL 2x18-40 CHF EL 1x36 HF EL 1x18-42 CHF EL 2x36 HF EL 2x36 HF2F* EL 1x9-13 CHF EL 2x10/13 CHF EL 1x9-13 CHF EL 2x10/13 CHF EL 1x18 CHF EL 2x18 CHF EL 1x18-42 CHF EL 2x18-40 CHF Circuit power Mains current (W) (A) (kHz) 19 36 25 50 35 73 37 36 74 44 39 89 63 125 17.5 19 36 25 50 36 37 71 74 12 23 15 30 20 40 27 55 0.08 0.16 0.11 0.22 0.15 0.30 0.16 0.15 0.31 0.19 0.15 0.40 0.27 0.55 0.08 0.08 0.16 0.11 0.22 0.15 0.16 0.30 0.31 0.06 0.10 0.07 0.13 0.09 0.17 0.12 0.24 40-50 40-50 40-50 40-50 26 25 40-50 26 25 40-50 26 25 28 25 26 40-50 40-50 40-50 40-50 26 40-50 60 25 40-50 36-50 40-50 36-50 40-50 40-50 40-50 40-50 *230-240V 50-60Hz DATA SUBJECT TO CHANGE WITHOUT NOTICE T07 073 1A 1.11.2001 10.1 Operating EEI frequency A2 A2 A2 A2 A2 A3 A2 A2 A2 A3 A3 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 Lamp power Weight Wiring Dimensions (W) (g) no. no. 16 16 23 23 31 32 30 32 32 40 34 40 55 55 15 16 16 23 22 32 31 32 32 10 10 13 13 18 18 25 25 150 200 150 200 270 340 150 270 340 150 270 340 270 340 270 150 200 150 200 270 150 340 340 150 190 150 190 150 190 150 200 57 58 57 58 55 56 57 55 56 57 55 56 55 56 55 57 58 57 58 55 57 56 56 57 58 57 58 57 58 57 58 31 32 31 32 26 27 31 26 27 31 26 27 26 27 26 31 32 31 32 26 31 27 27 31 32 31 32 31 32 31 32 Electronic ballasts for COMPACT LAMPS 9-55W TC-SE Lamp type W TC-TE Ballast 220-240V 50-60Hz Circuit power Mains current Operating EEI frequency (W) (A) (kHz) Lamp power Weight Wiring (W) (g) no. Dimensions no. no. 1 2 1 EL 1x9-13 CHF EL 2x10/13 CHF EL 1x9-13 CHF 10 20 13 0.05 0.09 0.06 40-50 36-50 40-50 - 9 9 11 150 190 150 57 58 57 31 32 31 2 1 2 1 2 1 2 1 1 2 EL 2x10/13 CHF EL 1x9-13 CHF EL 2x10/13 CHF EL 1x18 CHF EL 2x18 CHF EL 1x18-42 CHF EL 2x18-40 CHF EL 1x18-42 CHF EL 2x18-40 CHF EL 1x18-42 CHF EL 2x42 CHF 26 15 30 20 40 27 55 37 73 48 94 0.12 0.07 0.13 0.09 0.17 0.12 0.24 0.16 0.32 0.21 0.41 36-50 40-50 36-50 40-50 40-50 40-50 40-50 40-50 40-50 40-50 42-52 A2 A2 A2 A2 A2 A2 A2 A2 11 13 13 16 16 24 25 32 32 44 44 190 150 190 150 190 150 200 150 200 150 360 58 57 58 57 58 57 58 57 58 57 55 32 31 32 31 32 31 32 31 32 31 33 1 EL 1x18 HF 20 0.11 26 - 17 270 55 26 1 EL 1x36 HF 38 0.17 26 - 33 270 55 26 1 EL 1x55 HF2F 60 0.22 28 - 45 270 55 26 22 1 EL 1x18-42 CHF 25 0.11 40-50 A2 23 150 57 31 2 EL 2x18-40 CHF 36 0.16 40-50 A2 22 200 58 32 40 1 EL 1x18-42 CHF 44 0.19 40-50 A2 38 150 57 31 2 1) EL 2x18-40 CHF 71 0.31 40-50 A2 22 / 39 200 58 32 9 11 13 18 26 32 42 TC-T5C TC-DD No. of lamps Standard 21 38 55 1) One 22 watt lamp and one 40 watt lamp DATA SUBJECT TO CHANGE WITHOUT NOTICE T07 073 1A 1.11.2001 10.2 Electronic ballasts for COMPACT LAMPS 10-55W Controllable 220-240V 50-60Hz • Warm start according to lamp standards • Energy saving • Dimming range 5-100% • Low weight • Flickerless light • Covers EMC requirements • Low harmonics • Stabilized output • Low earth leakage current Lamp type W TC-L TC-F TC-DE * Ballast 1 2 1 2 1 2 EL 1x18 CHFC-L/F EL 2x18 CHFC-L/F EL 1x24 CHFC-L/F EL 2x24 CHFC-L/F EL 1x36 HFC2F EL 2x36 HFC2F 1 EL 1x40 HFC2F 32 1 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 EL 1x55 HFC2F EL 1x18 CHFC-L/F EL 2x18 CHFC-L/F EL 1x24 CHFC-L/F EL 2x24 CHFC-L/F EL 1x10/13 CHFC EL 2x10/13 CHFC EL 1x10/13 CHFC EL 2x10/13 CHFC EL 1x18 CHFC EL 2x18 CHFC EL 1x26 CHFC EL 2x26 CHFC EL 1x10/13 CHFC EL 2x10/13 CHFC EL 1x18 CHFC EL 2x18 CHFC EL 1x26 CHFC EL 2x26 CHFC EL 1x32 CHFC EL 2x32 CHFC 42 1 EL 1x42 CHFC 18 24 36 40 55 18 24 10 13 18 26 13 TC-TE * No. of lamps 18 26 Circuit power Mains current Lamp power Weight Wiring Dimensions (W) (A) (kHz) (W) (g) no. no. 20.5 37 27 50 37 72 0.09 0.17 0.12 0.22 0.17 0.32 40-100 40-120 40-100 40-120 40-56 40-74 A1 A1 A1 A1 A1 A1 17.5 17 23.5 23 32 32 210 360 210 360 320 400 62 63 62 63 60 61 32 33 32 33 34 35 44 0.20 45-73 A1 40 320 60 34 64 20.5 37 27 50 11.5 23 15.5 29 21 39 29 56 15.5 29 21 39 29 56 37 72 0.28 0.09 0.17 0.12 0.22 0.05 0.10 0.07 0.13 0.10 0.17 0.13 0.24 0.07 0.13 0.10 0.17 0.13 0.24 0.16 0.31 40-70 40-100 40-120 40-100 40-120 45-90 50-100 45-90 50-100 45-90 40-80 40-100 30-80 45-90 50-100 45-90 40-80 40-100 30-80 40-100 30-80 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 55 17.5 17 23.5 23 9.5 9.5 12.5 11.5 17.5 17.5 25.5 25.5 12.5 13 18 17 25.5 25.5 33 33 320 210 360 210 360 190 340 190 340 210 360 190 360 190 340 210 360 190 360 220 380 60 62 63 62 63 62 63 62 63 62 63 62 63 62 63 62 63 62 63 62 63 34 32 33 32 33 32 33 32 33 32 33 32 33 32 33 32 33 32 33 32 33 48 0.21 45-85 A1 43 220 62 32 * Dimming range 10-100% DATA SUBJECT TO CHANGE WITHOUT NOTICE T07 074 1A 1.11.2001 10.3 Operating EEI frequency 11 Wiring diagrams of MAGNETIC BALLASTS for FLUORESCENT T8 and UV LAMPS 1 2 3 4 5 DATA SUBJECT TO CHANGE WITHOUT NOTICE T10 126 1A 23.10.2001 11.1 Wiring diagrams of MAGNETIC BALLASTS for COMPACT FLUORESCENT LAMPS 7 8 9 10 11 12 13 13a L N DATA SUBJECT TO CHANGE WITHOUT NOTICE T10 127 1A 23.10.2001 11.2 Wiring diagrams of MAGNETIC BALLASTS for HIGH PRESURE MERCURY LAMPS 14 15 16 17 18 19 20 21 22 23 24 DATA SUBJECT TO CHANGE WITHOUT NOTICE T11 032 1A 23.10.2001 11.3 Wiring diagrams of MAGNETIC BALLASTS for HIGH PRESURE SODIUM LAMPS 26 27 28 29 30 31 32 33 34 35 DATA SUBJECT TO CHANGE WITHOUT NOTICE T11 036 1A 23.10.2001 11.4 Wiring diagrams of MAGNETIC BALLASTS for METAL HALIDE LAMPS 37a 37b 38 39 40 41 42 43 DATA SUBJECT TO CHANGE WITHOUT NOTICE T11 038 1A 23.10.2001 11.5 12 Wiring diagrams of ELECTRONIC BALLASTS for T8 LAMPS Standard 45 46 47 L N 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 48 NOTE: All wiring to the connectors marked with a black dot; • (hot wires) shoul be as short as possible. DATA SUBJECT TO CHANGE WITHOUT NOTICE T07 075 1A 1.11.2001 12.1 Wiring diagrams of ELECTRONIC BALLASTS for T8 LAMPS Controllable 49 1-10 VDC control < 1mA 50 1-10 VDC control < 1mA L N C1 + C0 - 1 2 3 4 5 9 6 10 7 11 8 12 13 14 15 16 NOTE: All wiring to the connectors marked with a black dot; • (hot wires) shoul be as short as possible. DATA SUBJECT TO CHANGE WITHOUT NOTICE T07 075 1A 1.11.2001 12.2 Wiring diagrams of ELECTRONIC BALLASTS for COMPACT LAMPS Standard 55 56 57 58 59 NOTE: All wiring to the connectors marked with a black dot; • (hot wires) shoul be as short as possible. In 57, 58 and 59 hot wires are marked to the ballast case DATA SUBJECT TO CHANGE WITHOUT NOTICE T07 076 1A 23.10.2001 12.3 Wiring diagrams of ELECTRONIC BALLASTS for COMPACT LAMPS Controllable 60 1-10 VDC control < 1mA 61 1-10 VDC control < 1mA 62 63 1-10 VDC control < 0.8mA 1-10 VDC control < 0.8mA NOTE: All wiring to the connectors marked with a black dot; • (hot wires) shoul be as short as possible. In 62 and 63 hot wires are marked to the ballast case DATA SUBJECT TO CHANGE WITHOUT NOTICE T07 076 1A 23.10.2001 12.4 Wiring diagrams of ELECTRONIC BALLASTS for T5 LAMPS Standard 64 65 66a L N 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 66b 67 NOTE: All wiring to the connectors marked with a black dot; • (hot wires) shoul be as short as possible. DATA SUBJECT TO CHANGE WITHOUT NOTICE T07 077 1B 4.12.2001 12.5 Wiring diagrams of ELECTRONIC BALLASTS for T5 LAMPS Controllable 68 1-10 VDC control < 1mA 69 1-10 VDC control < 1mA NOTE: All wiring to the connectors marked with a black dot; • (hot wires) shoul be as short as possible. DATA SUBJECT TO CHANGE WITHOUT NOTICE T07 077 1B 4.12.2001 12.6 Wiring diagrams of ELECTRONIC BALLASTS for T5 LAMPS Digital 70 DALI input + Power supply 1-10 VDC control < 1mA DALI input 71 DALI input + Power supply 1-10 VDC control < 1mA DALI input NOTE: All wiring to the connectors marked with a black dot; • (hot wires) shoul be as short as possible. DATA SUBJECT TO CHANGE WITHOUT NOTICE T07 077 1B 4.12.2001 12.7 13 Dimensions of MAGNETIC BALLASTS Ballasts for Fluorescent, Compact fluorescent and UV-Suntanning lamps DIMENSION NO. DRAWING LENGTH 'a' (mm) WIDTH 'b' (mm) HEIGHT 'c' (mm) 'd' (mm) 'e' (mm) 1 2 3 4 5 6 7 8 9 1 150 42 28 140 1 190 42 28 180 2 150 42 28.8 140 2 230 42 28.8 220 2 190 42 28.8 180 2 110 42 28.8 100 2 115 42 28.8 105 3 85 41,5 28 73 4 133 66 53 120 52 1 2 3 4 DATA SUBJECT TO CHANGE WITHOUT NOTICE T10 128 1A 23.10.2001 13.1 Dimensions of MAGNETIC BALLASTS High pressure discharge lamps DIMENSION NO. 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 DRAWING 1 LENGTH 'a' (mm) 125 WIDTH 'b' (mm) 42 HEIGHT 'c' (mm) 28.8 'd' (mm) 115 'e' (mm) 'f' (mm) 'g' (mm) 1 150 42 28.8 140 1 190 42 28.8 180 1 230 42 28.8 220 2 135 70 85 120 35 85 2 135 70 85 120 35 108 2 165 70 85 150 35 138 3 104 70 85 90 90 85 80 3 104 70 85 90 90 108 80 3 135 70 85 100 100 138 90 4 114 54 45,5 95 5 196 105 90 180 75-82 6 84 66 53 71 52 6 111 66 53 98 52 6 133 66 53 120 52 6 160 66 53 147 52 1 2 T-type 4 3 5 6 DATA SUBJECT TO CHANGE WITHOUT NOTICE T11 027 1A 23.10.2001 13.2 F-type 14 Dimensions of STANDARD ELECTRONIC BALLASTS DIMENSION NO 26 27 28 29 30 31 32 33 DRAWING LENGTH 'a' (mm) WIDTH 'b' (mm) HEIGHT 'c' (mm) 'd' (mm) 'e' (mm) 'f' (mm) 'g' (mm) 1 280 30 28 270 270 1 360 30 28 350 350 1 430 30 28 420 420 2 280 30 21 270 270 2 360 30 21 350 350 3 103 67 30 110 83,5 57,5 93,5 3 123 79 33 129,5 99 67 111 3 158 102 38 171,5 134 90 146 1 CLASSIC CASE SIDE MOUNT CASE 2 e c a 3 DATA SUBJECT TO CHANGE WITHOUT NOTICE T07 070 1A 22.10.2001 14.1 Dimensions of CONTROLLABLE ELECTRONIC BALLASTS DIMENSION NO. DRAWING LENGTH 'a' (mm) W IDTH 'b' (mm) HEIGHT 'c' (mm) 'd' (mm) 'e' (mm) 'f' (mm) 'g' (mm) 32 33 34 35 1 123 79 33 129,5 99 67 111 1 158 102 38 171,5 134 90 146 2 360 30 28 350 350 2 430 30 28 420 420 1 2 CLASSIC CASE SIDE MOUNT CASE DATA SUBJECT TO CHANGE WITHOUT NOTICE T07 071 1A 22.10.2001 14.2 Dimensions of DIGITAL ELECTRONIC BALLASTS DIMENSION NO. 36 DRAWING LENGTH 'a' (mm) W IDTH 'b' (mm) HEIGHT 'c' (mm) 'd' (mm) 'e' (mm) 1 1 360 30 28 350 350 37 1 430 30 28 420 420 CLASSIC CASE SIDE MOUNT CASE DATA SUBJECT TO CHANGE WITHOUT NOTICE T07 072 1A 22.10.2001 14.3 15 CHARACTERISTICS OF ELECTRONIC BALLASTS FOR T5 LAMPS Technical values Max.temperature at tc point EL-s EL-HFT5 EL-HFCT5 EL-HFIT5 80°C 80°C 80°C 80°C Ambient temperature range -20…+50°C 0…+50°C +10…+50°C +10…+50°C Storage temperature range -40…+80°C -40…+80°C -40…+80°C -40…+80°C Maximum relative humidity no condensation no condensation no condensation no condensation Number of starts per lamp >25 000 > 25 000 >20 000 > 20 000 Mains voltage tolerance ±10 % ±10 % ±10 % ±10 % DC range 200 - 300 VDC 200 - 300 VDC 200 - 300 VDC 200 - 300 VDC Over voltage duration 300 VAC 300 VAC 320 VAC, 1h 320 VAC, 1h Power factor (at maximum) 0.98 0.98 0.98 0.98 Earth leakage current < 0.4 mA < 0.4 mA < 0.4 mA < 0.4 mA Maximum working voltage (Uout) Lifetime - - - 500 V 90 000 h, at 60°C Tc 90 000 h, at 60°C Tc 90 000 h, at 60°C Tc 90 000 h, at 60°C Tc 2m 2m 2 m 2m EL-s EL-HFT5 EL-HFCT5 EL-HFIT5 X X X X X X X X Max length of ballast to lamp wiring Standards CE marked General and safety requirements EN 60928 Performance requirements EN 60929 X X X X Lamp life acc. to EN 60081 X X X X Warm start acc. to EN 60929 X X X X EN 61000-3-2 X X X X Radio Frequency Interference, acc. to EN 55015 Mains current harmonics, acc. to X X X X Immunity standard, acc. to EN 61547 X X X X Vibration test EN 60068-2-64 test Fh X X X X Bump test EN 60068-2-29 test Eb X X X X VDE 0108 X X X X X - - Can be used on DC, acc. to Thermal protection class EN 60928, B.5e X DATA SUBJECT TO CHANGE WITHOUT NOTICE T070811A 3.12.2001 15.1 CHARACTERISTICS OF ELECTRONIC BALLASTS FOR T8 LAMPS Technical values EL-HF EL-HFC Max. temperature at tc point 80 °C 75/80 °C Ambient temperature range -20...+50°C 1) 0…+50 °C 6) Storage temperature range -40...+80 °C -40...+80 °C Maximum relative humidity no condensation no condensation Number of starts per lamp > 50 000 >20 000 Mains voltage tolerance ±10 % ±10 % DC range 180 - 300 VDC 180 - 300 VDC Over voltage 320 VAC, 1 h 300 VAC Power factor (at maximum) 0.98 0.98 Earth leakage current < 0.5 mA < 0.5 mA Maximum working voltage (r.m.s.) U-out 300 VAC - Lifetime 90 000h, at 60°C Tc 90 000h, at 50°C Tc Max length of ballast to lamp wiring < 2m < 2m EL-HF EL-HFC X X Standards CE marked General and safety requirements EN 60928 X X Performance requirements EN 60929 X X 3) Lamp life according to EN 60081 X X 2) Warm start acc. to EN 60929 X X Mains current harmonics acc. to EN 61000-3-2 X X Radio Frequency Interference acc. to EN 55015 X X Immunity standard acc. to EN 61547 X X 4) Vibration test EN 60068-2-64 test Fh X X Bump test EN 60068-2-29 test Eb X X X X Can be used on DC, acc. to VDE 0108 Thermal protection acc. to EN60928 B.5e X 5) 1) 0...+50°C for 32W, 70W, 3x18W & 4x18W 2) 3x18 W, 4x18 W and 70 W. Warm start acc. to Helvar standard 3) 70W meets most requirements in EN 60929 4) Not EL-HFC 70W 5) Not EL 2x18 HF, EL 2x32 HF, EL 3x18 HF, EL 4x18 HF 6) 70W +15 - +50°C DATA SUBJECT TO CHANGE WITHOUT NOTICE T07 079 1A 3.12.2001 15.2 CHARACTERISTICS OF ELECTRONIC BALLASTS FOR COMPACT LAMPS Technical values Max. temperature at tc point EL-HF2F EL-CHF 75°C 70 / 75°C EL-HFC2F EL-CHFC 75 / 80°C 1) 70 / 75°C 2) Ambient temperature range 0…+50°C -15…+50°C Storage temperature range -40…+80°C -30…+80°C -40…+80°C -30…+80°C Maximum relative humidity no condensation no condensation no condensation no condensation Number of starts per lamp > 20 000 > 20 000 > 20 000 > 20 000 +15…+50°C +5…+50°C Mains voltage tolerance ±10 % ±10 % ±10 % ±10 % DC range 180 - 300 VDC 176-276 VDC 180-300 VDC 180-275 VDC Over voltage 320 VAC, 1h 380 V / 3 min 300 VAC 380 V / 3 min Power factor (at maximum) 0.98 0.95 0.98 0.97 Earth leakage current < 0.5 mA < 0.4 mA < 0.4 mA < 0.4 mA Maximum working voltage (r.m.s.) U-out Lifetime 90 000 h, at 50°C Tc 50 000 h, at Tc max 250 V 90 000 h, at 50°C Tc 50 000 h, at Tc max Max length of ballast to lamp wiring 1m 1m 0.5 m 1m EL-HF2F EL-CHF EL-HFC2F EL-CHFC X Standards CE marked X X X General and safety requirements EN 60928 X X X X Performance requirements EN 60929 X X - X Lamp life acc. to EN 60081 X X X X Warm start, acc. to EN 60929 X Mains current harmonics, acc. to Radio Frequency Interference Immunity standard, acc. to X - X X X X X EN 55015 X X X X X X X EN 61000-3-2 EN 61547 - 2) Vibration test EN 60068-2-64 test Fh X - X - Bump test EN 60068-2-29 test Eb X - X - Can be used on DC, acc. to Thermal protection acc. to VDE 0108 X X X X EN 60928 B.5e X X X X 1) EL 1x18-42 CHF = -20 - +60°C, EL 2x18-40 CHF = -20…+50°C 2) For 36 W 0…50°C DATA SUBJECT TO CHANGE WITHOUT NOTICE T07 080 1A 3.12.2001 15.3 16 MAGNETIC BALLASTS & IGNITORS - Instructions for use All Helvar ballasts are designed to be installed into the same fitting as the lamps they are operating. Always ensure that all ballast specifications are not exceeded under actual usage conditions. Wiring considerations 1. Fluorescent lamp ballasts Wire type • Solid core conductor only Mineral insulated cable • Not advised Wiring insulation • According to recommendations in EN 60598 Wire release from ballast • Use a 1mm² solid pin (or similar) - push in terminals. Wire cross section dimensions • 0.5 - 1.0mm² Wiring layout • Keep all wiring as short as possible • Mains wiring and lamp should always be kept as far as possible from each-other • Mains wiring should not be bunched together with lamp wiring • Avoid wiring 'loops' (to minimise magnetic coupling effect) • Avoid long parallel cable runs Wire preparation • Strip length 8.0mm ± 1mm Wire connections • As shown on the ballast label and the Wiring Diagram datasheets 2. HID (High Intensity Discharge) lamp ballasts Wire type Ballasts with push in terminals: • Solid core conductor only Ballasts with screw terminals: • Solid core or stranded conductor Wiring insulation • According to recommendations in EN 60598 Wire cross section dimensions Ballasts with push in terminals: • 0.5 - 1.5mm² Ballasts with screw terminals: • 1.5 - 3.0 mm² Mineral insulated cable • Not advised Wire release from ballast Ballasts with push in terminals: • Use a 1mm² solid pin (or similar) Ballasts with screw terminals: • Flat blade screwdriver Wire connections • As shown on the ballast label and the Wiring Diagram datasheets Wire preparation Ballasts with push in terminals: • Strip length 8.0mm ± 1mm Ballasts with screw terminals: • Strip length 7.0mm ± 1mm Wiring layout • Keep all wiring as short as possible • Mains wiring and lamp should always be kept as far as possible from each-other • Mains wiring should not be bunched together with lamp wiring • Avoid wiring 'loops' (to minimise magnetic coupling effect) • Avoid long parallel cable runs DATA SUBJECT TO CHANGE WITHOUT NOTICE O10 134 1A 24.1.2002 16.1 MAGNETIC BALLASTS & IGNITORS - Instructions for use 3. Ignitors for HID lamps Wire type • Solid core or stranded conductor Mineral insulated cable • Not advised Wiring insulation • According to recommendations in EN 60598 Wire preparation • Strip length 7.0mm ± 1mm Wire cross section dimensions • 1.5 - 3.0 mm² or 2.0 - 4.0 mm² (depending upon ignitor type) • 2.5 - 5.0 mm² (1000W ignitors) Wire release from ignitor • Flat blade screwdriver Wire connections • As shown on the ignitor label and datasheet Wiring layout • Keep wiring from the ignitor to the lamp as short as possible Installation & operational considerations Reflector position Situating a reflector or metal plate very close to the lamp may increase RFI emissions and cause excessive leakage current of the fitting Ballast earthing • Required for safety Lifetime • Reliable operation and lifetime is only guaranteed if the maximum winding temperature of tw 130ºC is not exceeded under the conditions of normal use Ballast mounting • The ballast must be located in such a position as to ensure that its maximum winding temperature of tw 130ºC is not exceeded under the conditions of normal use • Mount the ballast against a flat surface to ensure good heat dissipation Starting aid • For reliable starting (and electrical safety) all metal parts of the fitting must be at the same electrical potential as the ballast case Fitting components • Ensure the correct electrical ratings for the lamps being used Ignitor choice • Helvar ballasts for Metal Halide or High Pressure Sodium lamps are only suitable for use with superimposed pulse type ignitors • Pulsar type ignitors (where a high starting voltage is applied to the ballast windings) are not suitable for Helvar ballasts. If used, the ballast winding insulation will be subjected to increased load. This will drastically shorten the ballast lifetime Protection against lamp rectification • Metal Halide & High-Pressure Sodium lamps can begin to rectify as they reach the end of their operational lifetime. This can cause excessive temperature in a fitting. As such, it is recommended that thermal protection be fitted in these luminaires • A thermal protection device should be fitted inside the luminaire • Helvar ballasts for Metal Halide & High-Pressure Sodium lamps are available with thermal protectors fitted • Use of ignitors with a timer facility also provide some protection against lamp rectification. Use in conjunction with a thermal protector Noise avoidance • Ensure the ballast is securely fixed within the luminaire • Fix the ballast at a minimum distance of 3mm from the side of the fitting • Ensure that the fitting is of rigid construction (especially at the point where the ballast is fitted) • In large fittings the ballast should be separated from the fitting by mounting it on an aluminium plate (approx. 2mm thick) • Mount as few ballasts as possible in one fitting • If using multiple ballasts in a fitting, ensure that the ballasts are mounted as far as possible from each other Site considerations Mixed technology on the same electrical circuit • Magnetic and electronic ballasts should not be connected to the same electrical circuit. The energy spikes produced by magnetic ballasts may result in damage to the electronic ballasts Miniature Circuit Breakers • 'Type C' MCB's having trip characteristics in accordance with EN 60898 are recommended. • 'Type B' MCB's are not recommended due to their sensitivity. If used, they must only be loaded to 60% of the equivalent 'Type C' MCB DATA SUBJECT TO CHANGE WITHOUT NOTICE O10 134 1A 24.1.2002 16.2 ELECTRONIC BALLASTS - Instructions for use All Helvar ballasts are designed to be installed into the same fitting as the lamps they are operating. Always ensure that all ballast specifications are not exceeded under actual usage conditions. Wiring considerations Wire type • Solid core conductor only Wire preparation • Strip length 7.5mm ± 1mm Wire cross section dimensions • 0.5 - 1.5mm² Wiring capacitance • 80pF / meter (typical) Wiring insulation • According to recommendations in EN 60598 Wire insertion force • 8 Newtons (typical) Maximum wire lengths • See Characteristics datasheets Wire release from ballast • Terminals have quick release push buttons • Some ballasts require the use of a 1mm² solid pin (or similar). Wire connections • As shown on the ballast label and the Wiring Diagram datasheets Wiring layout • Keep all wiring as short as possible (particularly the 'Hot' wires - see Wiring Diagrams datasheets) • 'Hot' wires should be of equal length • ‘Cold' wires should be of equal length • Mains wiring, lamp wiring and low voltage control wiring should always be kept as far as possible from eachother • Mains wiring should not be bunched together with lamp wiring • Mains wiring should not be bunched together with lamp wiring • Control (ELV) wiring should not be bunched together with mains or lamp wiring (to minimise cross-talk) • Avoid wiring 'loops' (to minimise magnetic coupling effect) • Avoid long parallel cable runs Installation & operational considerations Ballast earthing • EL-s range is suitable for Class II fittings (no earth required) • All other Helvar electronic ballasts require a protective earth to be connected to ensure reliable operation Maximum tc temperature • Reliable operation and lifetime is only guaranteed if the maximum tc point temperature is not exceeded under the conditions of use Master / Slave connection • Not advised Frequent switching • Helvar warm start ballasts may be used in conjunction with occupancy sensors as long as the 'on' period is greater than 20 minutes. Shorter switching period may reduce lamp life Switching off one lamp via lamp wires • Not permitted Starting aid • For reliable starting (and electrical safety) all metal parts of the fitting must be at the same electrical potential as the ballast case Reflector position • Situating a reflector or metal plate very close to the lamp may increase RFI emissions and cause excessive leakage current of the fitting Fitting components • Ensure the correct electrical ratings for the lamps being used (e.g. 500V rated lampholders are required for T5 lamps) Ballast mounting position • Ensure that the entire length of the ballast is against a flat surface to ensure good heat dissipation DATA SUBJECT TO CHANGE WITHOUT NOTICE O07 082 1A 13.12.2001 16.3 ELECTRONIC BALLASTS - Instructions for use Stand-by function The stand-by function in Helvar ballasts is designed specifically as a protection for the ballast. It is designed specifically to switch the lamps off when a lamp ‘end of lifetime’ condition occurs. Lamps can also fail in many other ways. As such, the exact operating state of the ballast under other lamp fault conditions depends on the specific failure. The ballast will not be harmed under any normal lamp failure condition. Lamp 'end of lifetime' If the electrical characteristics (e.g. lamp voltage) required by the lamps exceeds the internal preset value in the ballast, the ballast will recognise that one or more lamps has reached the end of its useful operational life. In such cases the ballast will switch off the supply to the lamps (stand-by) to prevent excessive voltage and / or current being supplied to the circuit. Emergency inverter units • Due to our continuing program of product development and improvement, Helvar's electronic ballast designs are evolving constantly. This natural evolution may affect compatibility between our electronic ballasts and emergency conversion modules. It is therefore the responsibility of either the fitting manufacturer, emergency unit supplier and/or system integrator to ensure the used combination is fully compatible. Emergency inverter unit recommendations • Use a 4 pole changeover device, with all 4 poles being used to disconnect the lamp • Disconnect the mains supply from the ballast before the emergency lamp is disconnected, and prior to its connection to the emergency unit • Reconnect the emergency lamp to the ballast before application of the mains supply. A time delay circuit can be used for this purpose • For multiple lamp ballasts, the wiring lengths for emergency and non-emergency lamps should be equal • Site considerations Insulation resistance testing on an installation • Carry out insulation resistance testing with the fittings disconnected from the mains supply whenever possible (the complete fitting has already been tested by the manufacturer) • If fittings are connected to the mains supply during an insulation resistance test, all Live phases and Neutral must be connected together before the test is carried out. • Ensure correct re-connection before the mains supply is re-applied. Mixed technology on the same electrical circuit • Magnetic and electronic ballasts should not be connected to the same electrical circuit. The energy spikes produced by magnetic ballasts may result in damage to the electronic ballasts. Infra-red (IR) system • Fluorescent lamps operated by electronic ballasts emit, not only visible light, but also infra-red light. In some instances this may cause interference to IR systems. To minimise the risk of problems the IR system should have a reduced receiving area. To guarantee successful functionality Helvar recommend that the manufacturer of the IR system be contacted prior to installation. Helvar ballasts typically operate at frequencies rarely used in IR applications. 3-phase supplies • Do not apply power to the ballast / fitting without ensuring the Neutral conductor is correctly connected • Do not disconnect the Neutral conductor unless the supply is off Miniature Circuit Breakers • 'Type C' MCB's having trip characteristics in accordance with EN 60898 are recommended. • 'Type B' MCB's are not recommended due to their sensitivity. If used, they must only be loaded to 60% of the equivalent 'Type C' MCB DATA SUBJECT TO CHANGE WITHOUT NOTICE O07 082 1A 13.12.2001 16.4 17 HELVAR ballasts for fluorescent lamps Lamp type ILCOS W Cap T5 - Lamp FD-H 4 G5 6 G5 8 G5 13 G5 Electronic ballast L8D L 8 DL 2) L8D L 8 DL 2) L8D L 11 D L 13 TL2-100mm L 13 DL 2) ø16mm 14 T8 - Lamp FD-E G5 21 G5 24 G5 28 G5 35 G5 39 G5 49 G5 54 G5 80 G5 ø26mm 18 32 36 G13 G13 G13 58 G13 70 G13 EL 1x14-35s EL 1x14HFT5 EL 3/4x14s EL 3x14HFT5 EL 1x14-35s EL 1x21HFT5 EL 1x24s EL 1x24HFT5 EL 1x14-35s EL 1x28HFT5 EL 2x14-35s EL 2x14HFT5 EL 1x28HFCT5 EL 1x28HFIT5 EL 1x14-35s EL 1x35HFT5 EL 1x35HFCT5 EL 1x35HFIT5 EL 1x39s EL 1x39HFT5 EL 1x49s EL 1x49HFT5 EL 1x54s EL 1x54HFT5 EL 1x80s EL 1x18HF EL 3x18HF 1) EL 1x18HFC EL 4x14HFT5 EL 2x14-35s EL 2x21HFT5 EL 2x24s EL 2x24HFT5 EL 2x14-35s EL 2x28HFT5 EL 2x28HFCT5 EL 2x28HFIT5 EL 2x14-35s EL 2x35HFT5 EL 2x35HFCT5 EL 2x35HFIT5 EL 2x39s EL 2x39HFT5 EL 2x49s EL 2x49HFT5 EL 2x54s EL 2x54HFT5 EL 2x18HF EL 4x18HF 1) EL 2x18HFC L 18 A-L L 18 TL2 L 18 TL3 L 18 TLB2 L 18 A-S L 20 A L 18 TL4 L 20 A-P L 26 TS5 - 100mm L 26 TS5 - 105mm EL 2x32HF EL 1x36HF EL 1x36HFC EL 2x36HF EL 2x36HFC EL 1x58HF EL 1x58HFC EL 2x58HF EL 2x58HFC EL 1x70HF EL 1x70HFC EL 2x70HF Types printed BOLD are ENEC approved combinations. 1) Approved to EN60928 2) Approved to EN60921 3) 240V 50Hz Other combinations mentioned are tested and recommended by Helvar DATA SUBJECT TO CHANGE WITHOUT NOTICE O13 095 1A 17.12.2001 Magnetic Ballast (230V 50Hz) 17.1 L 36 TL2 L 36 TL3 L 36 TL4 L 36 TLB2 L 36 A-S L 58 TL2 L 58 TL3 L 40 A-L L 40 A-M L 40 A-P L 40 A-S L 36 A-K L 58 A-S L 65 A L 58 TL4 L 65 A-M L 58 TL4 - 220mm L 58 TLB2 - 220mm L 58 TLB2 - 180mm L 65 A-P L 65 A-S L 58 A-K L 75 A 3) L 75 A-S 3) L 70 TL4 2)3) HELVAR ballasts for fluorescent lamps Lamp type ILCOS T12 - Lamp ø38mm FD-E W 20 G13 25 G13 40 65 T8-LAMP ø 26 mm FD-E l=450 mm l=720 mm l=970 mm l=900 mm 30 T5 circular Circline 15 16 23 l=970 mm l=1047 mm FD-E Cap L 15 A L 15 TL3 L 40 A-L L 40 A-M L 40 A-P L 40 A-S EL 1x58HF L 58 A-S L 58 TL4 - 220mm L 58 TLB2 - 220mm L 58 TLB2 - 180mm L 58 TL2 L 58 TL3 L 58 TL4 L 58 A-K EL 1x18HF L 15 A L 15 A-P L 16 D L 15 A-P L 30 A L 30 A-P L 42 A L 36 TL2 L 36 TL4 L 36 TLB2 L 36 A-S L 36 A-K L 36 TL3 L 42 A G13 G13 G13 G13 G13 36 38 G13 G13 42 22 40 22 32 40 G13 2GX13 2GX13 G10q G10q G10q EL 1x36HF EL 1x36HFC EL 1x36HF 1) EL 1x36HF EL 1x36HFC EL 2x36HF EL 2x36HFC EL 2x36HF EL 2x36HF EL 2x36HFC EL 1x18-42CHF EL 1x18-42CHF EL 2x18-40CHF EL 2x18-40CHF 3) 40 G13 80 85 100 G13 G13 G13 L 30 TL2 L 32 A L 36 TL2 L 36 TL3 L 36 TL4 L 36 TLB2 L 36 A-K L 36 TL2 L 36 TL3 L 36 TL4 L 36 TLB2 L 36 A-S L 80 A-S L 85 T6 L 100 T7 140 160 G13 G13 L 140 T9 L 160 EN EL 1x36HF FU-E Types printed BOLD are ENEC approved combinations. 1) Approved to EN60928 2) Approved to EN60921 3) For a combination of one 22W and one 40W T5 circular lamp Other combinations mentioned are tested and recommended by Helvar DATA SUBJECT TO CHANGE WITHOUT NOTICE O13 095 1A 17.12.2001 Magnetic Ballast (230V 50Hz) L 18 A-L L 20 A L 20 A-P G13 Mod-U-line UV suntanning lamps Electronic ballast 17.2 L 18 TL2 L 18 TL3 L 18 TL4 L 18 TLB2 L 15 A-P L 36 TL2 L 36 TL3 L 36 TL4 L 36 TLB2 L 36 A-S L 65 A L 65 A-M L 65 A-P L 65 A-S L 15 TL3 L 16 DL L 30 TL2 L40 A-L L40 A-M L40 A-P L40 A-S L 30 A L40 A-L L40 A-M L40 A-P L40 A-S L40 A-L L40 A-M L40 A-P L40 A-S L 36 A-K L 100 T9 L 100 T9-100mm 2) HELVAR ballasts for compact fluorescent lamps Lamp type TC-S 2 finger ILCOS with starter FSD-I TC-E 2 finger without starter FSD-E TC-D 4 finger W Cap 5 7 9 11 5 7 9 11 G23 G23 G23 G23 2G7 2G7 2G7 2G7 10 G24d-1 13 G24d-1 18 G24d-2 Electronic ballast EL 1x9-13CHF EL 1x9-13CHF TC-DE 4 finger without starter FSQ-E TC-T 6 finger 26 G24d-3 10 G24q-1 13 G24q-1 18 G24q-2 26 G24q-3 18 GX24d-2 EL 1x9-13CHF EL 1x10/13CHFC EL 1x9-13CHF EL 1x10/13CHFC EL 1x18CHF EL 1x18CHFC EL 1x18-42CHF EL 1x26CHFC TC-TE 6 finger without starter FSM-E TC-DD 2D-lamp GR8, for magnetic ballast only GR10q, for electronic ballast or magnetic with external starter FSS-E 26 GX24d-3 13 GX24q-1 18 GX24q-2 26 GX24q-3 32 GX24q-3 42 GX24q-4 10 GR8, GR10q 16 21 GR8, GR10q GR8, GR10q EL 1x18HF 28 GR8, GR10q EL 1x9-13CHF EL 1x10/13CHFC EL 1x18CHF EL 1x18CHFC EL 1x18-42CHF EL 1x26CHFC EL 1x18-42CHF EL 1x32CHFC EL 1x18-42CHF EL 1x42CHFC EL 1x36HF 38 GR8, GR10q 55 GR8, GR10q EL 1x55HF2F Types printed BOLD are ENEC approved combinations. 1) Approved to EN60921 Other combinations mentioned are tested and recommended by Helvar DATA SUBJECT TO CHANGE WITHOUT NOTICE O13 095 1A 17.12.2001 17.3 L11 DL 1) L11 DL 1) L11 DL 1) L11 DL 1) L13 D L13 TL2-100mm L13 D L13 TL2-100mm L18 D L18 TLD-100mm L20 A L18 TL2 L18 TL3 L26 TS5-105mm L26 TS5-100mm L13 DL 1) L13 DL 1) L18 DL L20 A-P L18 A-L L18 A-S L18 TL4 L18 TLB2 EL 2x10/13 CHF EL 2x10/13CHFC EL 2x10/13 CHF EL 2x10/13CHFC EL 2x18CHF EL 2x18CHFC EL 2x18-40CHF EL 2x26CHFC with starter FSM-I L11 D L11 D L11 D L11 D EL 2x10/13 CHF EL 2x10/13 CHF with starter FSQ-I Magnetic Ballast (230V 50Hz) L18 D L18 TLD-100mm L20 A L18 TL2 L18 TL3 L26 TS5-105mm L26 TS5-100mm L18 DL L13 D L13 TL2-100mm L16 D L21 TL2-100mm 1) L20 A L18 TL2 L18 TL3 L18 TLB2 L36 TL2 L36 TL3 L36 TL4 L36 TL2B2 L13 DL L20 A-P L18 A-L L18 A-S L18 TL4 L18 TLB2 EL 2x10/13 CHF EL 2x10/13CHFC EL 2x18CHF EL 2x18CHFC EL 2x18-40CHF EL 2x26CHFC EL 2x18-40CHF EL 2x32CHFC EL 2x42CHF L16 DL L20 A-P L18 A-S L18 A-L L18 TL4 L40 A-P L40 A-M L40 A-S L36 A-S L36 A-K HELVAR ballasts for compact fluorescent lamps Lamp type TC-L 2 finger ILCOS Cap Ø 17.5 18 FSD-E TC-F W 24 2G11 34 2G11 36 2G11 40 2G11 55 2G11 18 2G10 24 EL 1x18-42CHF EL 1x18CHFC-L/F EL 2x18-40CHF EL 2x18CHFC-L/F EL 1x18-42CHF EL 1x24CHFC-L/F EL 2x18-40CHF EL 2x24CHFC-L/F EL 1x36HF EL 2x36HF2F EL 1x18-42CHF EL 2x36HF2F EL 1x36HF EL 1x36HFC2F 1) EL 2x36HFC2F 1) EL 1x18-42CHF EL 2x36HF2F EL 1x55HF2F EL 2x55HF2F EL 1x36HF 1) EL 1x40HFC2F 1) EL 1x55HFC2F 1) 2G11 Flat 4 finger FSS-E Electronic ballast EL 1x18HF EL 1x18-42CHF EL 1x18CHFC-L/F EL 2x18-40CHF EL 2x18CHFC-L/F EL 1x18-42CHF EL 1x24CHFC-L/F EL2x18-40CHF EL 2x24CHFC-L/F 2G10 EL 1x18-42CHF EL 1x36HF 36 2G10 Types printed BOLD are ENEC approved combinations. 1) Approved to EN60928 Other combinations mentioned are tested and recommended by Helvar DATA SUBJECT TO CHANGE WITHOUT NOTICE O13 095 1A 17.12.2001 17.4 EL 2x36HF EL 2x36HF2F Magnetic Ballast (230V 50Hz) L26 TS5-100mm L26 TS5-105mm L20 A L18 TL2 L18 TL3 L26 TS5-100mm L26 TS5-105mm L20 A L18 TL2 L18 TL3 L18 TL4 L18 TLB2 L20 A-P L18 A-S L18 A-L L18 TL4 L18 TLB2 L20 A-P L18 A-S L18 A-L L36 TL2 L36 TL3 L36 TL4 L36 A-K L36 TLB2 L40 A-P L40 A-M L40 A-S L36 A-S L20 A L18 TL2 L18 TL3 L18 TL4 L20 A L18 TL2 L18 TL3 L18 TL4 L26 TS5-100mm L26 TS5-105mm L40 A-P L40 A-M L36 TL2 L36 TL3 L36 TL4 L20 A-P L18 A-S L18 A-L L18 TLB2 L20 A-P L18 A-S L18 A-L L18 TLB2 L40 A-S L36 A-S L36 TLB2 L36 A-K Markings of lamp types Name Symbol Marking Cap Sylvania Osram Philips Thorn Tungsram GE T26 (T8) G13 F L TL F F T16 (T5) G5 F L TL F F TC-S G23 LYNX-S Dulux S PL-S - FD Biax™ S TC-SE 2G7 LYNX-SE Dulux SE PL-S - FD/E Biax™ SE TC - D G 24 d LYNX-D Dulux D PL-C - FD-D Biax™ D TC-DE G 24 q LYNX-DE Dulux D/E PL-C - FD-D/E Biax™ D/E TC-T GX 24 d LYNX-T Dulux T PL-T - - Biax™ T TC-TE GX 24 q LYNX-TE Dulux T/E PL-T - - Biax™ T/E, QE TC-L 2 G 11 LYNX-L,-LE Dulux L PL-L 2L FD-L Biax™ L TC-DD GR8,GR10q - - - 2D - Biax™ 2D™ Fluorescent lamps Compact fluorescent lamps T-R,28/30,T9 G 10 q FC FC TL-E - - Circline® T-R,16,T5 2GX13 FC FC TL 5 C - - - TC-F 2 G 10 LYNX-F Dulux F - - - - HME E27, E 40 HSL HQL HPL MBF HqLI HqLI HMG E27 - HQL-B HPL-B - - - HMR E27, E40 HSR-BW HQL-R HPL-R MBFR - MBFR HST E 27, E40 SHP-T NAV-T SON-T SON-T TCF SON-T HSE E 27, E40 SHP-E NAV-E SON SON-E TCL SON-E HSE-I E 27, E40 SHP/I NAV-E SON - - Lucalox I HST-DE R 7 S, Fc 2 - NAV-TS - SON-TD - SON-TD HSE-X E27, E 40 SHX NAV-E SON-H - - SONClassique HIT G 12 HIS-T HQI-T MHN-T (PG12) MBI-T/ BOH - MBI-T HIT E 40 HIS-T HQI-T HPI-TD MQI-T HqMIF MBIF HIT-DE R 7 S, Fc 2 HIS-TD HQI-TS MHN-TD MBIL HPI-TD HqMIS MQI HIT-I E40 - HQI-T HPI-BUS - - MBI-T HIE E27, E 40 M (E27) HQI-E HPI MBI HqMIL MBI HIR E40 - HQI-R - - HqMIR - High pressure mercury lamps High pressure sodium lamps Substitutive high pressure sodium lamps Metal halide lamps DATA SUBJECT TO CHANGE WITHOUT NOTICE O13 094 1A 14.2.2002 17.5 18 Packing details for MAGNETIC and ELECTRONIC BALLASTS Magnetic ballasts & ignitors UNIT PACKAGE BALLAST TYPE TRANSPORTATION PACKAGE PCS PLASTIC CARTON BINDING BOX STRIP ALF 18 - 36TL TS,TLD,21TL 13 TL 58 - 100W 10 10 10 10 10 X X X X X LA 40W 10 X LA 65W L11D SHID BHID E250 - 400T, H400T NK150 - 250T E250 - 400F, H400F NK150 - 250F NK400T/F 10 30 4 X EURO-HID 3 IGNITORS 50 X EURPALLET PALLET HEIGHT KG CM 1800 960 720-1190 1010-1159 605 1080 A 602-1256 AP 545-1135 720-1215 612 527-1170 53 63 38 45 68 68 58 40 50 800X1200 770X1080 730X650 730X1120 PCS PCS PCS PCS 1250 2100 1200 750 2000 1000 1200 1800 X 1400 1500 750 840 - 2000 960 1200 720 432 5 X 300 530-750 48 4 X 240 530-1060 48 860-910 50 X 360-450630 DATA SUBJECT TO CHANGE WITHOUT NOTICE 18.1.2002 PALLET WEIGHT ONE WAY PALLET DIMENSIONS OF PALLETS 18.1 Packing details for MAGNETIC and ELECTRONIC BALLASTS Electronic ballasts UNIT PACKAGE BALLAST TYPE EL1 x HF, EL1 x HFT5 EL1 x HFC, EL2 x HF, EL2 x HFT5 EL1 x HFCT5 EL1 x HFTI5 EL3 x HF, EL4 x HF, EL2 x HFC EL2 x HFCT5 EL2 x HFIT5 EL1 x s EL2 x s EL3/4 x s EL1 x CHFC-L/F EL2 x 18CHFC-L/F EL2 x CHFC EL1 x CHFC EL2 x CHF EL2 x 18CHFC EL2 x 24CHFC-L/F EL2 x 10/13CHF EL1 x 10-13CHFC EL1 x 9-13CHF EL1 x 18CHF EL1 x 18-42CHF PCS TRANSPORTATION PACKAGE PLASTIC CARTON BINDING BOX STRIP PALLET PALLET ONE WAY PALLET EURWEIGHT HEIGHT DIMENSIONS OF PALLETS PALLET 800X1200 770X1080 730X650 730X1120 PCS PCS PCS PCS KG CM 10 X 1000 300 43 10 X 1000 370 60 10 X 840 360 54 10 X 1000 250 40 10 X 1000 320 40 20 X 25 X 35 X DATA SUBJECT TO CHANGE WITHOUT NOTICE 18.1.2002 18.2 19 DIGIDIM products For further information on Helvar‘s lighting control product range, please see the Helvar Lighting Control web site at www.helvar.co.uk MULTI-SENSOR (312) The Multi-sensor module contains the required sensors to provide the energy saving benefits of an automated lighting control system; a constant light sensor, passive infra-red presence detector and infra-red remote control receiver. Constant Light Range of 5-5000 Lux Viewing angle 40 or 100 Omni-directional PIR Detector IR REMOTE CONTROL (303) The remote control is designed to operate basic system functions and to provide simple programming facilities. The remote has the following functions: On/off button. Raise (modifier button). Lower (modifier button). Four scene recall/configuration buttons. 1-10V CONVERTER (470) 1-10V DALI Converter suitable for controlling Helvar controllable ballasts thus enabling a DIGIDIM system to operate and to integrate into, existing analogue systems. Supply Voltage Supply Frequency Output Relay Rating Product Dimensions 197-264VAC (absolute) 48-62Hz (absolute) Single pole 10A resistive load (maximum 15 HFC ballasts) 90mm x 71mm x 58mm POWER SUPPLY (400) Supplies power to DALI control systems. Supply Voltage Supply Frequency DALI Power Supplied Product Dimensions 197-264VAC (absolute) 48-62Hz (absolute) 240mA (maximum) 90mm x 71mm x 58mm Note: This unit is not always required in systems that contain one or more of the following products; 416, 425, 450, 460 and DIGIDIM ballasts. DATA SUBJECT TO CHANGE WITHOUT NOTICE T13 098 1A 29.1.2002 19.1