Table of contents 1/2 Magnetic ballasts Electronic ballasts

advertisement
Table of contents 1/2
Magnetic ballasts
Ballasts for fluorescent T8 lamps
230V 50Hz
240V 50Hz
220V 50Hz
Ballasts for compact fluorescent lamps
230V 50Hz
240V 50Hz
220V 50Hz
1.
1.1
1.4
1.6
2.
2.1
2.4
2.6
Ballasts fo UV suntanning lamps
3.
230/240V 50Hz
3.1
Ballasts for High Pressure Mercury lamps
230V 50Hz
240V 50Hz
230, 240V 50Hz
220/230/240V 50Hz
Ballasts for High Pressure Sodium lamps
230V 50Hz
230/240V 50Hz
220/230/240V 50Hz
Ballasts for Metal Halide lamps
230/240V 50Hz
Electronic superimposed pulse ignitors
Without timer
With timer
Helvar ignitors for HPS & HI lamps
4.
4.1
4.2
4.3
4.4
5.
5.1
5.2
5.3
6.
6.1
7.
7.1
7.2
7.3
Electronic ballasts
Electronic ballasts for fluorescent T5 lamps
Standard
Cotrollable
Digital
Electronic ballasts for fluorescent T8 lamps
Standard
Controllable
Electronic ballasts for compact fluorescent lamps
Standard
Controllable
Help
8.
8.1
8.2
8.3
9.
9.1
9.2
10.
10.1
10.2
Table of contents 2/2
Wiring diagrams of magnetic ballasts
For fluorescent T8 and UV lamps
For compact fluorescent lamps
For High Pressure Mercury lamps
For High Pressure Sodium lamps
For Metal Halide lamps
L
N
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Wiring diagrams for electronic ballasts
For fluorescent T8 lamps
For compact fluorescent lamps
For fluorescent T5 lamps
Dimensions of magnetic ballasts
Ballasts for T8, compact & UV lamps
Ballasts for HID lamps
Dimensions of electronic ballasts
Standard electronic ballasts
Controllable electronic ballasts
Digital electronic ballasts
11.
11.1
11.2
11.3
11.4
11.5
12.
12.1
12.3
12.5
13.
13.1
13.2
14.
14.1
14.2
14.3
Characteristics of electronic ballasts
15.
For T5 lamps
For T8 lamps
For compact lamps
15.1
15.2
15.3
Magnetic ballasts
Electronic ballasts
16.1
16.3
Lamp ballast compatibility & approvals
Lamp markings
17.1
17.5
For magnetic ballasts
For electronic ballasts
18.1
18.2
Instructions for use
16.
Compatibility
17.
Packing details
Digidim products
18.
19.
19.1
Help
1
Magnetic ballasts for FLUORESCENT T8 LAMPS
15-65W
230V 50Hz
• Meets EN60920 & EN60921 requirements
• Low harmonics
• Low power losses
• Correctly trimmed lamp current guaranteed for
entire lifetime
• 100% quality controlled
• Double wire terminals without screws
• Small size
• Long lifetime
• CE marked
LAMP INFORMATION
T8 (G13)
Lamp Wattage Current
type
Length
BALLAST INFORMATION
COMPENSATION
Ballast type
Parallel Ck
230/250V
±10%
Mains
Current
EEI
(µF)
(A)
L 15 TL3
L 15 A-P
L 15 A
L 30 TL2
L 30 A
L 30 A-P
L 16 DL
L 16 D
L 18 TL2
L 18 TL3
L 18 TL4
L 18 TLB2
L 18 A-K
L 18 A-S
L 20 A
L 20 A-P
L 18 A-L
L 26 TS5 - 100
L 26 TS5 - 105
L 36 TL2
L 36 TL3
L 36 TL4
L 36 TLB2
L 36 A-K
L 36 A-S
4.5
4.5
4.5
4.5
4.5
4.5
2.0
2.0
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
0.16
0.16
0.16
0.21
0.21
0.21
0.11
0.11
0.16
0.16
0.16
0.16
0.16
0.16
0.16
0.16
0.16
0.16
0.16
0.26
0.26
0.26
0.26
0.,26
0.26
B1
C
C
B1
B1
B1
B1
B2
B2
B2
B2
C
C
C
C
C
-
Inductive
Temp. rise
ind/abn
EN 60920
Net
weight
Circuit
Diag.
Dimensions
λ
∆t (°C)
(kg)
No.
No.
0.30
0.31
0.35
0.45
0.50
0.50
0.43
0.46
0.30
0.30
0.30
0.32
0.34
0.32
0.35
0.35
0.35
0.32
0.32
0.45
0.45
0.45
0.48
0.50
0.55
40/70
50/95
55/80
30/70
55/110
50/125
60/150
65/150
35/60
40/70
45/80
50/95
55/95
50/80
55/95
55/95
75/90
65/100
65/100
35/90
40/90
45/110
50/145
50/145
45/125
0.76
0.56
0.62
0.84
0.62
0.56
0.32
0.32
0.84
0.76
0.65
0.55
0.62
0.67
0.62
0.56
0.52
0.50
0.50
0.84
0.76
0.65
0.57
0.67
0.67
1,2
1,2
1,2
4
4
4
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
4
4
4
4
4
4
3
1
1
3
1
1
8
8
3
3
3
3
1
1
1
1
1
6
7
3
3
3
3
1
1
(W)
(A)
(mm)
1 x 15
1 x 15
1 x 15
2 x 15
2 x 15
2 x 15
1 x 16
1 x 16
1 x 18
1 x 18
1 x 18
1 x 18
1 x 18
1 x 18
1 x 18
1 x 18
1 x 18
1 x 18
1 x 18
2 x 18
2 x 18
2 x 18
2 x 18
2 x 18
2 x 18
2 x 18
0.31
0.31
0.31
0.33
0.33
0.33
0.20
0.20
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
438
438
438
438
438
438
720
720
590
590
590
590
590
590
590
590
590
590
590
590
590
590
590
590
590
0.37
590
L 40 A-S
4.5
0.26
-
0.55
50/150
0.67
4
1
2 x 18
2 x 18
2 x 18
0.37
0.37
590
590
4.5
4.5
0.26
0.26
-
0.55
0.55
55/140
55/155
0.62
0.56
4
4
1
1
0.37
590
L 40 A-M
L 40 A-P
L 40 A-L 1)
4.5
0.26
-
0.55
75/160
0.52
4
1
1) Not available for European Union market from May 2002
DATA SUBJECT TO CHANGE WITHOUT NOTICE
T10 123 1B 4.12.2001
1.1
Magnetic ballasts for FLUORESCENT T8 LAMPS
15-65W
230V 50Hz
LAMP INFORMATION
T12 (G13)
T8 (G13)
T12 (G13)
Lamp Wattage Current
type
Length
BALLAST INFORMATION
COMPENSATION
Ballast type
Parallel Ck
230/250V
±10%
Mains
Current
(µF)
(A)
Induc- Temp. rise
tive
ind/abn
EN 60920
Net
weight
Circuit
Diag.
Dimensions
λ
∆t (°C)
(kg)
No.
No.
-
0.32
0.32
0.32
0.32
0.35
0.35
0.35
0.50
0.49
0.49
0.49
0.55
0.55
0.55
0.55
0.55
0.45
0.50
0.46
35/60
40/70
45/80
50/80
55/95
55/95
75/90
50/145
35/90
40/90
45/110
45/125
50/ 150
55/140
55/155
75/160
35/70
40/80
40/95
0.84
0.76
0.65
0.67
0.62
0.56
0.52
0.67
0.84
0.76
0.65
0.67
0.67
0.62
0.56
0.52
0.76
0.62
0.56
1,2
1,2
1,2
1,2
1,2
1,2
1,2
4
4
4
4
4
4
4
4
4
1,2
1,2
1,2
3
3
3
1
1
1
1
1
3
3
3
1
1
1
1
1
3
1
1
0.21
0.21
0.21
B1
B2
B2
0.45
0.45
0.45
30/70
55/110
50/125
0.84
0.62
0.56
1,2
1,2
1,2
3
1
1
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
0.26
0.26
0.26
0.26
0.26
0.26
0.26
0.26
0.26
0.26
0.26
0.26
0.26
0.26
0.26
0.26
0.26
0.26
0.26
B1
B1
B2
B2
B2
B2
C
C
C
D
-
0.43
0.43
0.43
0.45
0.45
0.45
0.50
0.50
0.50
0.50
0.45
0.45
0.45
0.48
0.48
0.48
0.48
0.48
0.48
35/90
40/90
45/110
50/145
50/145
45/125
50/150
55/140
55/155
75/160
35/90
40/90
45/110
50/145
45/125
50/150
55/140
55/155
75/160
0.84
0.76
0.65
0.57
0.67
0.67
0.67
0.62
0.56
0.52
0.84
0.76
0.65
0.67
0.67
0.67
0.62
0.56
0.52
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
3
3
3
3
1
1
1
1
1
1
3
3
3
1
1
1
1
1
1
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
0.26
0.26
0.26
0.26
0.26
0.26
0.26
0.26
-
0.47
0.47
0.47
0.50
0.50
0.50
0.50
0.50
35/90
40/90
45/110
45/125
50/150
55/140
55/155
75/160
0.84
0.76
0.65
0.67
0.67
0.62
0.56
0.52
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
3
3
3
1
1
1
1
1
(W)
(A)
(mm)
1 x 20
1 x 20
1 x 20
1 x 20
1 x 20
1 x 20
1 x 20
2 x 20
2 x 20
2 x 20
2 x 20
2 x 20
2 x 20
2 x 20
2 x 20
2 x 20
1 x 25
1 x 25
1 x 25
1 X 30
1 X 30
1 X 30
1 X 36
1 X 36
1 X 36
1 X 36
1 X 36
1 X 36
1 X 36
1 X 36
1 X 36
1 X 36
1 X 38
1 X 38
1 X 38
1 X 38
1 X 38
1 X 38
1 X 38
1 X 38
1 X 38
1 X 40
1 X 40
1 X 40
1 X 40
1 X 40
1 X 40
1 X 40
1 X 40
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.29
0.29
0.29
590
590
590
590
590
590
590
590
590
590
590
590
590
590
590
590
970
970
970
L 18 TL2
L 18 TL3
L 18 TL4
L 18 A-S
L 20 A
L 20 A-P
L 18 A-L
L 36 A-K
L 36 TL2
L 36 TL3
L 36 TL4
L 36 A-S
L 40 A-S
L 40 A-M
L 40 A-P
L 40 A-L 1)
L 15 TL3
L 15 A
L 15 A-P
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
3.5
3.5
3.5
0.16
0.16
0.16
0.16
0.16
0.16
0.16
0.26
0.26
0.26
0.26
0.26
0.26
0.26
0.26
0.26
0.15
0.15
0.15
0.365
0.365
0.365
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
900
900
900
1200
1200
1200
1200
1200
1200
1200
1200
1200
1200
1047
1047
1047
1047
1047
1047
1047
1047
1047
1200
1200
1200
1200
1200
1200
1200
1200
L 30 TL2
L 30 A
L 30 A-P
4.5
4.5
4.5
L 36 TL2
L 36 TL3
L 36 TL4
L 36 TLB2
L 36 A-K
L 36 A-S
L 40 A-S
L 40 A-M
L 40 A-P
L 40 A-L 1)
L 36 TL2
L 36 TL3
L 36 TL4
L 36 A-K
L 36 A-S
L 40 A-S
L 40 A-M
L 40 A-P
L 40 A-L 1)
L 36 TL2
L 36 TL3
L 36 TL4
L 36 A-S
L 40 A-S
L 40 A-M
L 40 A-P
L 40 A-L 1)
1) Tolerance ±2%
2) Not available for European Union market from May 2002
DATA SUBJECT TO CHANGE WITHOUT NOTICE
T10 123 1B 4.12.2001
EEI
1.2
Magnetic ballasts for FLUORESCENT T8 LAMPS
15-65W
230V 50Hz
LAMP INFORMATION
T12 (G13)
T8 (G13)
Lamp Wattage Current Length
type
BALLAST INFORMATION
COMPENSATION
Ballast type
Parallel Ck
230/250V
±10%
Mains
Current
(µF)
(A)
EEI
Inductive
Temp. rise
ind/abn
EN 60920
Net
weight
Circuit
Diag.
Dimensions
λ
∆t (°C)
(kg)
No.
No.
(W)
(A)
(mm)
1 X 42
0.53
1047
L 42 A
6.0
0.26
-
0.45
55/110
1.00
1,2
2
1 X 58
1 X 58
1 X 58
1 X 58
1 X 58
1 X 58
1 X 58
1 X 58
1 X 58
1 X 58
1 X 58
1 X 58
1 X 65
1 X 65
1 X 65
1 X 65
1 X 65
1 X 65
1 X 65
1 X 65
1 X 65
1 X 65
1 X 65
1 X 65
0.67
0.67
0.67
0.67
0.67
0.67
0.67
0.67
0.67
0.67
0.67
0.67
0.67
0.67
0.67
0.67
0.67
0.67
0.67
0.67
0.67
0.67
0.67
0.67
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
L 58 TL2
L 58 TL3
L 58 TLB2 -220mm
L 58 TLB2 -180mm
L 58 TL4 -220mm
L 58 TL4
L 58 A-S
L 58 A-K
L 65 A-S
L 65 A-M
L 65 A
L 65 A-P
L 58 TL2
L 58 TL3
L 58 TL4 -220mm
L 58 TL4
L 58 TLB2 -220mm
L 58 TLB2 -180mm
L 58 A-S
L 58 A-K
L 65 A-S
L 65 A-M
L 65 A
L 65 A-P
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
7.0
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
0.35
B1
B1
B2
B2
B2
B2
B2
B2
C
C
C
C
-
0.45
0.45
0.47
0.47
0.45
0.45
0.48
0.48
0.50
0.50
0.50
0.50
0.45
0.45
0.45
0.45
0.47
0.47
0.48
0.48
0.50
0.50
0.50
0.50
35/95
40/95
50/140
50/140
40/110
40/110
45/130
50/145
50/135
60/140
55/145
55/145
35/95
40/95
40/110
40/110
50/140
50/140
45/130
50/145
50/135
60/140
55/145
55/145
1.41
1.30
0.91
0.90
1.06
1.06
1.05
1.05
1.05
1.05
1.00
0.87
1.41
1.30
1.06
1.06
0.91
0.90
1.05
1.05
1.05
1.05
1.00
0.87
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
4
4
4
5
4
5
2
2
2
2
2
2
4
4
4
5
4
5
2
2
2
2
2
2
DATA SUBJECT TO CHANGE WITHOUT NOTICE
T10 123 1B 4.12.2001
1.3
Magnetic ballasts for FLUORESCENT T8 LAMPS
15-125W
240V 50Hz
• Meets EN60920 & EN60921 requirements
• Low harmonics
• Low power losses
• Correctly trimmed lamp current guaranteed for
entire lifetime
• 100% quality controlled
• Double wire terminals without screws
• Small size
• Long lifetime
• CE marked
LAMP INFORMATION
T12
T8 (G13)
T12 (G13)
T8 (G13)
Lamp Wattage
type
Current
Length
(W)
(A)
(mm)
1 x 15
1 x 15
2 x 15
2 x 15
1 x 18
1 x 18
1 x 18
1 x 18
1 x 18
1 x 18
2 x 18
2 x 18
2 x 18
2 x 18
1 x 20
1 x 20
1 x 20
1 x 20
2 x 20
2 x 20
2 x 20
2 x 20
1 x 25
1 x 25
1 x 30
1 x 30
1 x 36
1 x 36
1 x 36
1 x 36
1 x 38
1 x 38
1 x 38
1 x 38
1 x 40
1 x 40
1 x 40
1 x 40
0.31
0.30
0.31
0.31
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.29
0.29
0.365
0.365
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
438
438
438
438
590
590
590
590
590
590
590
590
590
590
590
590
590
590
590
590
590
590
970
970
900
900
1200
1200
1200
1200
1047
1047
1047
1047
1200
1200
1200
1200
BALLAST INFORMATION
COMPENSATION
Ballast type
L 15 A-P
L 15 A
L 30 A-P
L 30 A
L 18 TL2
L 18 TL4
L 20 A
L 20 A-P
L 26 TS5 -100
L 26 TS5 -105
L 36 TL2
L 36 TL4
L 40 A
L 40 A-P
L 18 TL2
L 18 TL4
L 20 A
L 20 A-P
L 36 TL2
L 36 TL4
L 40 A
L 40 A-P
L 15 A
L 15 A-P
L 30 A
L 30 A-P
L 36 TL2
L 36 TL4
L 40 A
L 40 A-P
L 36 TL2
L 36 TL4
L 40 A
L 40 A-P
L 36 TL2
L 36 TL4
L 40 A
L 40 A-P
Parallel Ck
240/250V
±10%
Mains
Current
(µF)
(A)
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.5
4.5
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
3.0
3.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
0.11
0.11
0.17
0.17
0.16
0.16
0.13
0.13
0.16
0.16
0.22
0.22
0.23
0.23
0.16
0.16
0.14
0.14
0.22
0.22
0.23
0.23
0.14
0.14
0.17
0.17
0.22
0.22
0.23
0.23
0.22
0.22
0.23
0.23
0.22
0.22
0.23
0.23
DATA SUBJECT TO CHANGE WITHOUT NOTICE
T10 124 1B 10.04.2002
1.4
EEI
C
C
C
C
C
C
B1
C
C
-
Inductive
Temp. rise
ind/abn
EN 60920
Net
weight
Circuit DimenDiag.
sions
λ
∆t (°C)
(kg)
No.
No.
0.31
0.35
0.45
0.45
0.30
0.29
0.35
0.35
0.31
0.31
0.44
0.44
0.53
0.53
0.32
0.31
0.35
0.35
0.48
0.48
0.53
0.53
0.45
0.49
0.45
0.45
0.42
0.42
0.50
0.50
0.44
0.44
0.50
0.52
0.46
0.46
0.50
0.50
60/85
55/90
55/125
55/125
40/65
45/80
60/90
60/90
65/110
65/110
35/95
45/115
55/ 70/160
40/65
45/80
60/90
60/90
35/95
45/115
55/ 70/160
55/90
60/85
55/125
55/125
35/95
45/115
55/ 70/160
35/95
45/115
55/ 70/160
35/95
45/115
55/ 70/160
0.56
0.63
0.56
0.63
0.84
0.65
0.63
0.56
0.50
0.50
0.84
0.65
0.63
0.56
0.84
0.65
0.63
0.56
0.84
0.65
0.63
0.56
0.63
0.56
0.63
0.56
0.84
0.65
0.63
0.56
0.84
0.65
0.63
0.56
0.84
0.65
0.63
0.56
1,2
1,2
4
4
1,2
1,2
1,2
1,2
1,2
1,2
4
4
4
4
1,2
1,2
1,2
1,2
4
4
4
4
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1
1
1
1
3
3
1
1
6
7
3
3
1
1
3
3
1
1
3
3
1
1
1
1
1
1
3
3
1
1
3
3
1
1
3
3
1
1
Magnetic ballasts for FLUORESCENT T8 LAMPS
15-125W
240V 50Hz
LAMP INFORMATION
T8 (G13)
T12 (G13) T8 (G13)
Lamp Wattage Current Length
type
BALLAST INFORMATION
COMPENSATION
Ballast type
Parallel Ck
240/250V
±10%
Mains
Current
(µF)
(A)
EEI
Inductive
Net
weight
λ
Temp. rise
ind/abn
EN 60920
∆t (°C)
Circuit DimenDiag. sions
(kg)
No.
No.
35/95
45/115
60/140
60/145
60/145
1.41
1.06
1.12
1.00
0.90
1,2
1,2
1,2
1,2
1,2
4
4
2
2
2
(W)
(A)
(mm)
1 x 58
1 x 58
1 x 58
1 x 58
1 x 58
0.67
0.67
0.67
0.67
0.67
1500
1500
1500
1500
1500
L 58 TL2
L 58 TL4
L 65 A-S
L 65 A
L 65 A-P
7.0
7.0
7.0
7.0
7.0
0.35
0.35
0.31
0.31
0.31
B1
B2
C
C
C
0.42
0.42
0.45
0.50
0.50
1 x 65
0.67
1500
L 58 TL2
7.0
0.35
-
0.42
35/95
1.41
1,2
4
1 x 65
0.67
1500
L 58 TL4
7.0
0.35
-
0.42
45/115
1.06
1,2
4
1 x 65
0.67
1500
L 65 A-S
7.0
0.31
-
0.45
60/140
1.12
1,2
2
1 x 65
0.67
1500
L 65 A
7.0
0.31
-
0.50
60
1.00
1,2
2
1 x 65
1 x 70
1 x 70
1 x 70
1 X 75
1 x 85
1 X 100
1 X 100
1 X 125
1 X 125
0.67
0.70
0.70
0.70
0.67
0.80
0.96
0.96
0.94
0.94
1500
1800
1800
1800
1800
1800
2400
2400
2400
2400
L 65 A-P
L 75 A-S
L 75 A
L 70 TL4
L 70 TL4
L 85 A-S
L100 TE61
L100 TE8
L100 TE61
L100 TE8
7.0
6.0
6.0
6.0
6.0
8.0
10.0
10.0
0.31
0.41
0.41
0.40
0.40
0.43
0.55
0.55
-
C
B2
-
0.50
0.55
0.55
0.50
0.54
0.55
0.52
0.50
2)
0.62c
2)
0.60c
60/145
60
65
45
45
65
55/145
75/190
55/145
75/190
0.90
1.12
1.00
1.32
1.32
1.12
1.32
1.32
1.32
1.32
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
3
3
2
2
2
5
5
2
4
4
4
4
1)
1)
-
1) Essential: Series capacitor 7.2µF ±4% 440V
2) Capacitive
DATA SUBJECT TO CHANGE WITHOUT NOTICE
T10 124 1B 10.04.2002
1.5
Magnetic ballasts for FLUORESCENT T8 LAMPS
15-65W
220V 50Hz
• Meets EN60920 & EN60921 requirements
• Low harmonics
• Low power losses
• Correctly trimmed lamp current guaranteed for
entire lifetime
• 100% quality controlled
• Double wire terminals without screws
• Small size
• Long lifetime
• CE marked
LAMP INFORMATION
T12 T8
T12
T8 (G13)
T12 (G13)
T8 (G13)
Lamp Wattage
type
BALLAST INFORMATION
COMPENSATION
Parallel Ck
240/250V
±10%
Mains
Current
Power
Losses
(µF)
(A)
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
3.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
7.0
2)
5.7
L 58 TL2
7.0
L 65 A
5.7
Current
Length
(W)
(A)
(mm)
1 x 15
2 x 15
1 x 18
1 x 18
1 x 18
2 x 18
2 x 18
2 x 18
1 x 20
1 x 20
1 x 20
2 x 20
2 x 20
2 x 20
1 x 25
1 x 30
1 x 36
1 x 36
1 x 36
1 x 38
1 x 38
1 x 38
1 x 40
1 x 40
1 x 40
1 x 58
1 x 58
0.31
0.31
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.29
0.36
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.67
0.67
438
438
590
590
590
590
590
590
590
590
590
590
590
590
970
900
1200
1200
1200
1047
1047
1047
1200
1200
1200
1500
1500
L 15A-P
L 30A-P
L 18 TL2
L 20A-P
L 18 A-L
L 36 TL2
L 40 A-P
3)
L 40 A-L
1 x 65
0.67
1500
1 x 65
0.67
1500
Ballast type
L 18 TL2
L 20 A-P
L 18 A-L
L 36 TL2
L 40 A-P
3)
L 40 A-L
L 15 A-P
L 30 A-P
L 36 TL2
L 40 A-P
3)
L 40 A-L
L 36 TL2
L 40 A-P
3)
L 40 A-L
L 36 TL2
L 40 A-P
3)
L 40 A-L
L 58 TL2
L 65 A
2)
1) Winding at 25°C
2) Tolerance ±4 %
3) Not available for European Union market from May 2002
DATA SUBJECT TO CHANGE WITHOUT NOTICE
T10 121 1B 10.04.2002
1.6
Inductive
Temp. rise
ind/abn
EN 60920
Net
weight
Circuit
Diag.
Dimensions
(W)
λ
∆t (°C)
(kg)
No.
No.
0.16
0.21
0.16
0.16
0.16
0.26
0.27
0.27
0.16
0.16
0.16
0.26
0.27
0.27
0.15
0.21
0.26
0.27
0.27
0.26
0.27
0.27
0.26
0.27
0.27
0.35
0.34
8.2
7.5
5.5
9.0
9.3
5.5
9.2
9.5
5.5
9.0
9.3
5.5
9.2
9.5
6.7
7.5
5.5
9.2
9.5
5.5
9.2
9.5
5.5
9.2
9.5
8
12
0.35
0.50
0.30
0.35
0.35
0.49
0.53
0.55
0.32
0.35
0.35
0.49
0.55
0.55
0.50
0.50
0.43
0.50
0.50
0.45
0.49
0.49
0.47
0.50
0.50
0.47
0.50
50/85
45/110
35/50
55/85
65/90
35/90
55/155
65/160
35/50
55/85
65/90
35/90
55/155
65/160
50/85
45/110
35/90
55/155
65/160
35/90
55/155
65/160
35/90
55/155
65/160
35/95
55/140
0.56
0.56
0.76
0.56
0.52
0.76
0.56
0.52
0.76
0.56
0.52
0.76
0.56
0.52
0.56
0.56
0.76
0.56
0.52
0.76
0.56
0.52
0.76
0.56
0.52
1.30
1.30
1,2
4
1,2
1,2
1,2
4
4
4
1,2
1,2
1,2
4
4
4
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1
1
3
1
1
3
1
1
3
1
1
3
1
1
1
1
3
1
1
3
1
1
3
1
1
4
2
0.35
8
0.47
35/95
1.30
1,2
4
0.34
12
0.50
55/140
1.00
1,2
2
1)
2
Magnetic ballasts for COMPACT FLUORESCENT & T5 LAMPS
4-36W
230V 50Hz
• Meets EN60920 & EN60921 requirements
• Low power losses
• 100% quality controlled
• Double wire terminals without screws
• Low harmonics
• Very low magnetic field
• Small size
• Long lifetime
• CE marked
LAMP INFORMATION
TC-S ( G23)
T5 ( G5)
Lamp Wattage Current Length
type
(W)
(A)
(mm)
1x4
1x4
2x4
2x4
1x6
1x6
2x6
2x6
2x6
1x8
1x8
1x8
2x8
2x8
2x8
1 x 13
1 x 13
1 x 13
1x5
1x5
2x5
2x5
2x5
1x7
1x7
2x7
2x7
2x7
1x9
1x9
2x9
2x9
2x9
1 x 11
1 x 11
0.17
0.17
0.17
0.17
0.16
0.16
0.16
0.16
0.16
0.145
0.145
0.145
0.145
0.145
0.147
0.165
0.165
0.165
0.18
0.18
0.18
0.18
0.18
0.18
0.18
0.18
0.18
0.18
0.17
0.17
0.17
0.17
0.17
0.155
0.155
136
136
136
136
212
212
212
212
212
288
288
288
288
288
288
517
517
517
105
105
105
105
105
135
135
135
135
135
170
170
170
170
170
240
240
BALLAST INFORMATION
COMPENSATION
Ballast type
L8 DL
L8 D
L8 DL
L8 D
L8 DL
L8 D
L13 TL2 -100mm
L 13 DL
L 13 D
L8 DL
L8 D
L11 D
L13 DL
L16 DL
L16 D
L13 TL2 -100mm
L 13 DL
L 13 D
L11 DL
L11 D
L13 TL2 -100mm
L 13 DL
L 13 D
L11 DL
L11 D
L13 TL2 -100mm
L 13 DL
L 13 D
L11 DL
L11 D
L13 TL2 -100mm
L 13 DL
L 13 D
L11 DL
L11 D
Parallel Ck
230/250V
±10%
Mains
Current
(µF)
(A)
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
0.06
0.06
0.06
0.06
0.06
0.06
0.08
0.10
0.10
0.06
0.06
0.06
0.10
0.11
0.11
0.08
0.10
0.10
0.07
0.07
0.08
0.10
0.10
0.07
0.07
0.08
0.10
0.10
0.07
0.07
0.09
0.10
0.10
0.08
0.08
DATA SUBJECT TO CHANGE WITHOUT NOTICE
T10 130 1B 10.04.2002
2.1
EEI
-
Inductive
Temp. rise
ind/abn
EN60920
Net
weight
Circuit
Diag.
Dimensions
λ
∆t (°C)
(kg)
No.
No.
0.25
0.25
0.35
0.35
0.30
0.30
0.41
0.45
0.45
0.35
0.33
0.33
0.50
0.43
0.50
0.43
0.45
0.45
0.28
0.25
0.36
0.35
0.40
0.30
0.28
0.46
0.45
0.45
0.32
0.33
0.56
0.55
0.55
0.43
0.43
55/95
65/90
55/95
65/90
55/95
65/90
30/40
50/95
65/120
55/95
65/90
60/85
50/95
60/150
65/150
30/40
50/95
65/120
60/95
60/85
30/40
50/95
65/120
60/95
60/85
30/40
50/95
65/120
60/95
60/85
30/40
50/95
65/120
60/95
60/85
0.32
0.32
0.32
0.32
0.32
0.32
0.5
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.5
0.32
0.32
0.32
0.32
0.5
0.32
0.32
0.32
0.32
0.5
0.32
0.32
0.32
0.32
0.5
0.32
0.32
0.32
0.32
7
7
8
8
7
7
8
8
8
7
7
7
8
8
8
7
7
7
9
9
11
11
11
9
9
11
11
11
9
9
11
11
11
9
9
8
8
8
8
8
8
6
8
8
8
8
8
8
8
8
6
8
8
8
8
6
8
8
8
8
6
8
8
8
8
6
8
8
8
8
Magnetic ballasts for COMPACT FLUORESCENT & T5 LAMPS
4-36W
230V 50Hz
LAMP INFORMATION
TC-L ( 2G11)
Lamp Wattage Current Length
type
(W)
(A)
(mm)
1 x 18
1 x 18
1 x 18
1 x 18
1 x 18
1 x 18
1 x 18
1 x 18
1 x 18
1 x 18
2 x 18
2 x 18
2 x 18
2 x 18
2 x 18
2 x 18
2 x 18
2 x 18
2 x 18
2 x 18
1 x 24
1 x 24
1 x 24
1 x 24
1 x 24
1 x 24
1 x 24
1 X 24
1 X 24
1 x 24
1 X 36
1 X 36
1 X 36
1 X 36
1 X 36
1 X 36
1 X 36
1 X 36
1 X 36
1 X 36
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.34
0.34
0.345
0.345
0.34
0.34
0.34
0.345
0.345
0.34
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
225
225
225
225
225
225
225
225
225
225
225
225
225
225
225
225
225
225
225
225
320
320
320
320
320
320
320
320
320
320
415
415
415
415
415
415
415
415
415
415
BALLAST INFORMATION
COMPENSATION
Ballast type
L18 TL2
L18 TL3
L18 TL4
L18 TLB2
L18 A-S
L20 A
L20 A-P
L26 TS5 -100mm
L26 TS5 -105mm
L18 A-L
L36 A-K
L36 TL2
L36 TL3
L36 TL4
L36 TLB2
L36 A-S
L40 A-S
L40 A-M
L40 A-P
L40 A-L
L18 TL2
L18 TL3
L18 TL4
L18 TLB2
L18 A-S
L20 A
L20 A-P
L26 TS5 -100mm
L26 TS5 -105mm
L18 A-L
L36 TL2
L36 TL3
L36 TL4
L36 TLB2
L36 A-K
L36 A-S
L40 A-S
L40 A-M
L40 A-P
L40 A-L
Parallel Ck
230/250V
±10%
Mains
Current
(µF)
(A)
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
0.16
0.16
0.16
0.16
0.16
0.16
0.16
0.16
0.16
0.16
0.26
0.26
0.26
0.26
0.26
0.26
0.26
0.26
0.26
0.26
0.18
0.18
0.18
0.18
0.18
0.18
0.18
0.18
0.18
0.18
0.26
0.26
0.26
0.26
0.26
0.26
0.26
0.26
0.26
0.26
DATA SUBJECT TO CHANGE WITHOUT NOTICE
T10 130 1B 10.04.2002
2.2
EEI
B1
B1
B2
B2
B2
C
C
C
C
B1
B1
B1
B2
B2
B2
B2
B2
B2
C
B1
B1
B2
B2
B2
B2
C
C
C
D
Induc- Temp. rise
tive
ind/abn
EN 60920
Net
weight
Circuit
Diag.
Dimensions
λ
∆t (°C)
(kg)
No.
No.
0.30
0.30
0.30
0.32
0.32
0.35
0.35
0.32
0.32
0.35
0.50
0.45
0.45
0.45
0.48
0.50
0.55
0.55
0.55
0.55
0.38
0.38
0.41
0.41
0.40
0.42
0.42
0.40
0.40
0.42
0.43
0.43
0.43
0.45
0.45
0.50
0.50
0.50
0.50
0.50
35/60
40/70
45/80
50/95
50/80
55/95
55/95
65/100
65/100
75/90
50/145
35/90
40/90
45/110
50/145
45/125
50/150
55/140
55/155
75/160
35/60
40/70
45/80
50/95
50/80
55/95
55/95
65/100
65/100
75/90
35/90
40/90
45/110
50/145
50/145
45/125
50/150
55/140
55/155
75/160
0.84
0.76
0.65
0.55
0.67
0.62
0.56
0.50
0.50
0.52
0.67
0.84
0.76
0.65
0.57
0.67
0.67
0.62
0.56
0.52
0.84
0.76
0.65
0.55
0.67
0.62
0.56
0.50
0.50
0.52
0.84
0.76
0.65
0.57
0.67
0.67
0.67
0.62
0.56
0.52
10
10
10
10
10
10
10
10
10
10
12
12
12
12
12
12
12
12
12
12
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
3
3
3
3
1
1
1
6
7
1
1
3
3
3
3
1
1
1
1
1
3
3
3
3
1
1
1
6
7
1
3
3
3
3
1
1
1
1
1
1
Magnetic ballasts for COMPACT FLUORESCENT & T5 LAMPS
4-36W
230V 50Hz
LAMP INFORMATION
Lamp Wattage Current Length
type
(A)
Ballast type
(mm)
Parallel Ck
230/250V
±10%
Mains
Current
(µF)
(A)
EEI
Induc- Temp. rise
tive
ind/abn
EN 60920
Net
weight
Circuit
Diag.
Dimensions
λ
∆t (°C)
(kg)
No.
No.
1 x 16
0.20
140
L16 DL
2.0
0.11
-
0.43
60/150
0.32
13
8
1 x 16
1 x 21
0.20
0.26
140
140
L16 D
L21 TL2 -100mm
2.0
3.0
0.11
0.16
B2
B1
0.46
0.40
65/150
40/70
0.32
0.5
13
13
8
6
1 x 28
0.325
205
L18 TL2
3.5
0.20
-
0.48
35/60
0.84
13
3
1 x 28
0.325
205
L18 TL3
3.5
0.20
-
0.48
40/70
0.76
13
3
1 x 28
0.32
205
L18 TL4
3.5
0.20
-
0.44
45/80
0.65
13
3
1 x 28
0.325
205
L18 TLB2
3.5
0.20
B2
0.48
50/95
0.55
13
3
1 x 28
0.32
205
L18 A-S
3.5
0.20
B2
0.48
50/80
0.67
13
1
1 x 28
0.325
205
L20 A
3.5
0.20
-
0.50
55/95
0.62
13
1
0.32
205
L20 A-P
3.5
0.20
-
0.50
55/95
0.56
13
1
1 x 28
0.325
205
L18 A-L
3.5
0.20
C
0.50
75/90
0.52
13
1
1 x 22
0.40
220ø
L30 TL2
5.0
0.21
-
0.30
220ø
L30 A
5.0
0.21
-
0.35
0.84
0.62
3
0.40
40/70
60/110
13a
1 x 22
13a
1
1 x 32
0.45
312ø
L32 A
5.0
0.23
-
0.40
55/120
0.62
13a
1
1 x 10
1 x 10
1 x 10
0.19
110
L 13 TL2 -100mm
0.19
0.19
110
110
L13 DL
L13 D
2.0
2.0
2.0
0.08
0.08
0.08
B1
B2
B2
0.31
0.35
0.35
30/40
50/95
65/120
0.5
0.32
0.32
9
9
9
6
8
8
1 x 13
1 x 13
1 x 13
1 x 18
1 x 18
1 x 18
1 x 26
1 x 26
1 x 26
1 x 26
1 x 26
1 x 26
1 x 26
1 x 26
0.175
0.175
0.175
0.22
0.22
0.22
0.31
0.31
0.325
0.31
0.31
0.31
0.31
0.325
140
140
140
160
160
160
193
193
193
193
193
193
193
193
L 13 TL2 -100mm
L13 DL
L13 D
L18 TLD-100mm
L18 DL
L18 D
L18 TL2
L18 TL3
L18 TL4
L18 TLB2
L18 A-S
L20 A
2.0
2.0
2.0
2.0
2.0
2.0
3.5
3.5
3.5
3.5
3.5
3.5
0.08
0.10
0.10
0.12
0.14
0.14
0.18
0.18
0.18
0.18
0.18
0.18
A3
B1
B1
B1
B1
B1
B2
B2
-
0.43
0.45
0.45
0.45
0.45
0.50
0.43
0.43
0.45
0.45
0.43
0.45
30/40
50/95
65/120
30/60
60/150
65/155
35/60
40/70
45/80
50/95
50/80
55/95
0.5
0.32
0.32
0.5
0.32
0.32
0.84
0.76
0.65
0.55
0.67
0.62
9
9
9
9
9
9
9
9
9
9
9
9
6
8
8
6
8
8
3
3
3
3
1
1
L20 A-P
L26 TS5 -100mm
3.5
3.5
0.18
0.18
B2
B2
0.45
0.45
55/95
65/100
0.56
0.50
9
9
1
6
1 x 26
0.325
193
L26 TS5 -105mm
3.5
0.18
B2
0.45
65/100
0.50
9
6
1 x 26
0.31
193
L18 A-L
3.5
0.18
C
0.45
75/90
0.52
9
1
TC-D ( G 24 d)
1)
1 x 28
T-R
TC-DD ( GR 8) 2)
(W)
BALLAST INFORMATION
COMPENSATION
1) Cap G10q
2) Also GR 10q; external starter required
DATA SUBJECT TO CHANGE WITHOUT NOTICE
T10 130 1B 10.04.2002
2.3
Magnetic ballasts for COMPACT FLUORESCENT & T5 LAMPS
4-36W
240V 50Hz
• Meets EN60920 & EN60921 requirements
• Low power losses
• 100% quality controlled
• Double wire terminals without screws
• Low harmonics
• Very low magnetic field
• Small size
• Long lifetime
• CE marked
LAMP INFORMATION
TC-L (2 G11)
TC-D (G24d)
TC-S (G23)
T5 (G5)
Lamp Wattage Current Length
type
(W)
(A)
(mm)
1x4
2x4
1x6
2x6
1x8
1x8
2x8
1x13
1x5
2x5
1x7
2x7
1x9
2x9
1x11
1x16
0.17
0.17
0.16
0.16
0.145
0.145
0.175
0.165
0.18
0.18
0.18
0.18
0.17
0.17
0.155
0.2
136
136
212
212
288
288
288
517
105
105
135
135
170
170
240
720
BALLAST INFORMATION
COMPENSATION
Ballast type
L8D
L8D
L8D
L 13 D
L8D
L 11 D
L 16 D
L 13 D
L 11 D
L 13 D
L 11 D
L 13 D
L 11 D
L 13 D
L 11 D
L 16 D
Parallel Ck
240/250V
±10%
Mains Current EEI Inductive
(µF)
(A)
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
0.06
0.06
0.06
0.10
0.06
0.06
0.11
0.10
0.07
0.10
0.07
0.10
0.07
0.10
0.08
0.11
B2
Temp. rise
ind/abn
EN 60920
Net
weight
Circuit
Diag.
Dimensions
λ
∆t (°C)
(kg)
No.
No.
0.25
0.35
0.30
0.45
0.33
0.33
0.45
0.45
0.25
0.40
0.30
0.45
0.33
0.55
0.43
0.45
60/90
60/90
60/90
65/110
60/90
65/90
65/90
65/110
65/90
65/110
65/90
65/110
65/90
65/110
65/90
65/90
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
7
8
7
8
7
7
8
7
9
11
9
11
9
11
9
9
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
1x10
0.19
110
L 13 D
2.0
0.08
C
0.35
65/110
0.32
9
8
1x13
1x18
1x26
1x26
1x26
1x26
1x26
1x26
1x18
1x18
1x18
1x18
1x18
1x18
2x18
2x18
2x18
2x18
0.175
0.22
0.31
0.31
0.31
0.31
0.325
0.325
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
140
160
193
193
193
193
193
193
225
225
225
225
225
225
225
225
225
225
L 13 D
L 18 D
L 18 TL2
L 18 TL4
L 20 A
L 20 A-P
L 26 TS5 -100
L 26 TS5 -105
L 18 TL2
L 18 TL4
L 20 A
L 20 A-P
L 26 TS5 -100
L 26 TS5 -105
L 36 TL2
L 36 TL4
L 40 A
L 40 A-P
2.0
2.0
3.5
3.5
3.0
3.0
3.5
3.5
4.0
4.0
4.0
4.0
4.5
4.5
4.0
4.0
4.0
4.0
0.10
0.14
0.18
0.18
0.17
0.17
0.18
0.18
0.16
0.16
0.13
0.13
0.16
0.16
0.22
0.22
0.23
0.23
B2
B1
-
0.45
0.45
0.43
0.42
0.45
0.45
0.43
0.43
0.30
0.29
0.35
0.35
0.31
0.31
0.44
0.44
0.53
0.53
65/110
65/160
40/65
45/80
60/90
60/90
50/110
50/110
40/65
45/80
60/90
60/90
65/110
65/110
35/95
45/115
55/ 70/160
0.32
0.32
0.84
0.65
0.63
0.56
0.50
0.50
0.84
0.65
0.63
0.56
0.50
0.50
0.84
0.65
0.63
0.56
9
9
9
9
9
9
9
9
10
10
10
10
10
10
12
12
12
12
8
8
3
3
1
1
6
7
3
3
1
1
6
7
3
3
1
1
DATA SUBJECT TO CHANGE WITHOUT NOTICE
T10 131 1B 10.04.2002
2.4
Magnetic ballasts for COMPACT FLUORESCENT & T5 LAMPS
4-36W
240V 50Hz
LAMP INFORMATION
T-R 2) TC-DD 1)
TC-L ( 2 G11)
Lamp Wattage Current Length
type
BALLAST INFORMATION
COMPENSATION
Ballast type
Parallel Ck
240/250V
±10%
Mains
Current
(µF)
(A)
EEI
Inductive
Temp. rise
ind/abn
EN 60920
Net
weight
Circuit DimenDiag.
sions
λ
∆t (°C)
(kg)
No.
No.
(W)
(A)
(mm)
1 x 24
1 x 24
1 x 24
1 x 24
1 x 24
1 x 24
1 x 36
1 x 36
1 x 36
1 x 36
1 x 16
1 x 28
1 x 28
1 x 28
1 x 28
0.34
0.34
0.34
0.34
0.345
0.345
0.43
0.43
0.43
0.43
0.195
0.325
0.325
0.325
0.325
320
320
320
320
320
320
415
415
415
415
140
205
205
205
205
L 18 TL2
L 18 TL4
L 20 A
L 20 A-P
L 26 TS5 -100
L 26 TS5 -105
L 36 TL2
L 36 TL4
L 40 A
L 40 A-P
L 16 D
L 18 TL2
L 18 TL4
L 20 A
L 20 A-P
3.5
3.5
3.5
3.5
4.0
4.0
4.0
4.0
4.0
4.0
2.0
3.5
3.5
3.0
3.0
0.18
0.18
0.16
0.16
0.18
0.18
0.22
0.22
0.23
0.23
0.11
0.20
0.20
0.19
0.19
B2
-
0.48
0.47
0.42
0.42
0.38
0.38
0.42
0.42
0.52
0.50
0.45
0.48
0.47
0.50
0.50
40/65
45/80
60/90
60/90
55/110
55/110
35/95
45/115
55/ 70/ 65/160
40/65
45/80
60/90
60/90
0.84
0.65
0.63
0.56
0.50
0.50
0.84
0.65
0.63
0.56
0.32
0.84
0.65
0.63
0.56
10
10
10
10
10
10
10
10
10
10
13
13
13
13
13
3
3
1
1
6
7
3
3
1
1
8
3
3
1
1
1 x 22
1 x 32
0.40
0.45
220ø
312ø
L 30 A
L 32 A
5.0
4.0
0.21
0.18
-
0.35
0.40
60/125
65/140
0.63
0.63
13a
13a
1
1
1) Cap GR8 (also GR 10q); external starter required
2) Cap G10q
DATA SUBJECT TO CHANGE WITHOUT NOTICE
T10 131 1B 10.04.2002
2.5
Magnetic ballasts for COMPACT FLUORESCENT & T5 LAMPS
5-36W
220V 50Hz
• Meets EN60920 & EN60921 requirements
• Low power losses
• 100% quality controlled
• Double wire terminals without screws
• Low harmonics
• Very low magnetic field
• Small size
• Long lifetime
• CE marked
LAMP INFORMATION
Lamp Wattage Current Length
type
(W)
(A)
BALLAST INFORMATION
COMPENSATION
Ballast type
(mm)
TC-D (G24d)
TC-S (G23)
T5 (G5)
0.16
212
L 13 D
0.145
288
L 11 D
0.175
288
L 16 D
0.165
517
L 13 D
0.20
720
L 16 D
0.18
105
L 11 D
0.18
105
L 13 D
0.18
135
L 11 D
0.18
135
L 13 D
0.17
170
L 11 D
0.14
170
L 13 D
0.155
240
L 11 D
0.19
110
L 13 D
0.175
140
L 13 D
1 x 18
0.22
160
L 18 D
1 x 26
0.31
193
L 18 TL2
1 x 26
0.31
193
L 20 A-P
1 x 26
0.31
193
L 18 A-L
1 x 18
0.375
225
L 18 TL2
1 x 18
0.37
225
L 20 A-P
1 x 18
0.37
225
L 18 A-L
2 x 18
0.37
225
L 36 TL2
2 x 18
0.37
225
L 40 A-P
2 x 18
0.37
225
L 40 A-L
1 x 24
0.34
320
L 18 TL2
1 x 24
0.34
320
L 20 A-P
1 x 24
0.34
320
L 18 A-L
1 x 36
0.435
415
L 36 TL2
1 x 36
0.43
415
L 40 A-P
1 x 36
0.43
415
L 40 A-L
1 x 16
0.20
140
L 16 D
1 x 28
0.325
205
L 18 TL2
1 x 28
0.325
205
L 20 A-P
1 x 28
0.325
205
L 18 A-L
1) Winding at 25°C
2) Gap GR8, also GR 10q; external starter required
TC-DD 2)
TC-L (2G11)
2x6
1x8
2x8
1 x 13
1 x 16
1x5
2x5
1x7
2x7
1x9
2x9
1 x 11
1 x 10
1 x 13
Parallel Ck
240/250V
±10%
Mains
Current
Power
Losses
(µF)
(A)
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
3.5
3.5
3.5
4.5
4.5
4.5
4.5
4.5
4.5
4.0
4.0
4.0
4.5
4.5
4.5
2.0
3.5
3.5
3.5
0.10
0.06
0.11
0.10
0.11
0.07
0.10
0.07
0.10
0.07
0.10
0.08
0.08
0.10
0.14
0.18
0.18
0.18
0.16
0.16
0.16
0.26
0.27
0.27
0.18
0.18
0.18
0.26
0.27
0.27
0.11
0.20
0.20
0.20
DATA SUBJECT TO CHANGE WITHOUT NOTICE
T10 125 1B 10.04.2002
2.6
Inductive
Temp. rise
ind/abn
EN 60920
Net
weight
(W)
λ
∆t (°C)
(kg)
No.
No.
5.0
3.8
4.8
4.6
5.3
5.0
5.0
5.0
5.0
4.5
4.1
3.7
5.6
4.3
5.6
6.0
9.0
9.3
6.0
9.0
9.3
6.0
9.2
9.5
5.0
9.0
9.3
6.0
9.2
9.5
5.3
6.0
9.0
9.3
0.45
0.35
0.52
0.45
0.48
0.25
0.40
0.30
0.45
0.35
0.55
0.45
0.35
0.45
0.50
0.43
0.46
0.46
0.30
0.35
0.35
0.49
0.52
0.52
0.38
0.43
0.43
0.43
0.50
0.50
0.48
0.48
0.50
0.50
65/110
60/85
65/150
65/110
65/110
60/85
65/110
60/85
65/110
60/85
65/110
60/85
65/110
65/110
65/155
35/50
55/85
65/90
35/50
55/85
65/90
35/90
55/155
65/160
35/50
55/85
65/90
35/90
55/155
65/160
65/110
35/50
55/85
65/90
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.76
0.56
0.52
0.76
0.56
0.52
0.76
0.56
0.52
0.76
0.56
0.52
0.76
0.56
0.52
0.32
0.76
0.56
0.52
8
7
8
7
7
9
11
9
11
9
11
9
9
9
9
9
9
9
10
10
10
12
12
12
10
10
10
10
10
10
13
13
13
13
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
3
1
1
3
1
1
3
1
1
3
1
1
3
1
1
8
3
1
1
1)
Circuit DimenDiag.
sions
3
Magnetic ballasts for UV SUNTANNING LAMPS
80-160W
230, 240V 50Hz
• Low power losses
• Low harmonics
• 100% quality controlled
• Very low magnetic field
• Long lifetime
• Low noise
• Recyclable materials
• ’Automatic’ earthing
• CE marked
230V
LAMP INFORMATION
T8 (G13)
Lamp Wattage Current Length
type
(W)
(A)
(mm)
80
85
100
100
100
140
160
0.87
0.80
1.00
1.00
1.00
1.50
1.50
1500
1800
1800
1800
1800
1500
1800
BALLAST INFORMATION
COMPENSATION
Ballast type
L 80 A-S
L 85 T6
L 100 T7
L 100 T9
L 100 T9 -180
L 140 T9
L 160 EN
Voltage Parallel Ck
240/250V
±10%
230
230
230
230
230
230
230
240V
LAMP INFORMATION
Lamp Wattage Current Length
type
T8
(W)
(A)
Mains
Current
Inductive
Temp. rise
ind/abn
EN 60920
Net
weight
Circuit
Diag.
Dimensions
(µF)
(A)
λ
∆t (°C)
(kg)
No.
No.
8.0
8.0
10.0
10.0
10.0
18.0
14.0
0.47
0.45
0.55
0.55
0.55
0.77
0.77
0.50
0.55
0.50
0.50
0.50
0.50
0.52
70/170
55/160
60/145
70/190
70/190
80/190
60/150
1.01
1.01
1.32
1.10
1.07
1.50
2.00
1,2
1,2
1,2
1,2
1,2
1,2
5
2
5
4
4
5
4
9
BALLAST INFORMATION
COMPENSATION
Ballast type
Voltage Parallel Ck
240/250V
±10%
(mm)
(µF)
Mains
Current
Inductive
Temp. rise
ind/abn
EN 60920
Net
weight
Circuit
Diag.
Dimensions
(A)
λ
∆t (°C)
(kg)
No.
No.
85
0.80
1800
L 85 T6
240
8.0
0.45
0.50
55/ -
1.07
1,2
5
100
1.00
1800
L 100 T7
240
10.0
0.55
0.50
60/ -
1.32
1,2
4
100
1.00
1800
L 100 T9
240
10.0
0.55
0.50
70/ -
1.11
1,2
4
DATA SUBJECT TO CHANGE WITHOUT NOTICE
T10 129 1B 10.04.2002
3.1
4
Magnetic ballasts for HIGH PRESSURE MERCURY LAMPS
50-400W
230V 50Hz
• Meets EN60922 & EN60923 requirements
• Very low magnetic field
• 100% quality controlled
• Low power losses
• Low harmonics
• Low noise
• Long lifetime
• Multiple fixing point variations
• CE marked
LAMP INFORMATION
HM
Lamp
type
Wattage
Current
(W)
(A)
50
50
80
80
125
125
250
250
400
0.62
0.62
0.80
0.80
1.15
1.15
2.15
2.15
3.25
BALLAST INFORMATION
COMPENSATION
Ballast type
Parallel Ck
230/250V
±10%
Mains
Current
Power
losses
(µF)
(A)
7.0
7.0
8.0
8.0
10.0
10.0
18.0
18.0
25.0
0.30
0.30
0.45
0.45
0.70
0.70
1.40
1.40
2.15
E 50 LU
E 50 T7
E 80 LU
E 80 T7
E 125 LU
E 125 T7
E 250 EN
2)
E 250 T,F
2)
E 400 T,F
1) Winding at 25°C
2) T-type = two and four point fixing
F-type = four point fixing
DATA SUBJECT TO CHANGE WITHOUT NOTICE
T11 028 2A 23.10.2001
4.1
Inductive
Temp. rise
EN 60922
Net
weight
Circuit
Diag.
Dimensions
(W)
λ
∆t (°C)
(kg)
No.
No.
11.0
11.4
12.0
13.5
13.7
15.3
20.0
22.0
25.4
0.40
0.46
0.50
0.52
0.55
0.56
0.55
0.55
0.60
60
65
65
70
70
70
75
65
65
1.22
0.71
1.22
0.93
1.22
1.34
2.0
2.20
3.16
14
23
14
23
14
23
19
17
17
20
11
20
12
20
13
24
14,17
15,18
1)
Magnetic ballasts for HIGH PRESSURE MERCURY LAMPS
50-400W
240V 50Hz
• Meets EN60922 & EN60923 requirements
• Very low magnetic field
• 100% quality controlled
• Low power losses
• Low harmonics
• Low noise
• Long lifetime
• Multiple fixing point variations
• CE marked
LAMP INFORMATION
HM
Lamp
type
W attage
Current
(W)
(A)
50
80
125
250
250
400
0.62
0.80
1.15
2.15
2.15
3.25
BALLAST INFORMATION
COMPENSATION
Ballast type
Parallel Ck
230/250V
±10%
Mains
Current
Power
losses
(µF)
(A)
7.0
8.0
10.0
18.0
18.0
25.0
0.30
0.45
0.70
1.40
1.40
2.15
E 50 LU
E 80 LU
E 125 LU
E 250 EN
2)
E 250 T,F
2)
E 400 T,F
1) Winding at 25°C
2) T-type = two and four point fixing
F-type = four point fixing
DATA SUBJECT TO CHANGE WITHOUT NOTICE
T11 029 1A 23.10.2001
4.2
Inductive
Temp. rise
EN 60922
Net
weight
Circuit
Diag.
Dimensions
(W)
λ
∆t (°C)
(kg)
No.
No.
11.3
12.4
13.5
20.5
23.0
26.6
0.40
0.50
0.55
0.55
0.55
0.60
70
70
70
75
70
70
1.22
1.22
1.22
2.0
2.20
3.16
14
14
14
16
18
18
20
20
20
24
14,17
15,18
1)
Magnetic ballasts for HIGH PRESSURE MERCURY LAMPS with two lamp wattages
80/50W - 125/80W
230, 240V 50Hz
• Meets EN60922 & EN60923 requirements
• Very low magnetic field
• 100% quality controlled
• Low power losses
• Low harmonics
• Low noise
• Long lifetime
• Multiple fixing point variations
• CE marked
230V / 50Hz ballasts
LAMP INFORMATION
HM
Lamp Wattage
type
BALLAST INFORMATION
COMPENSATION
Current
Ballast type
Voltage Parallel Ck
230/250V
±10%
Power
losses
Inductive
(µF)
(A)
(W)1)
λ
(W)
(A)
80/50
0.80/0.62
E 80/50 LU
230
8.0
0.45/0.30
125/80
1.15/0.80
E 125/80 LU
230
10.0
0.70/0.45
240V / 50Hz ballasts
LAMP INFORMATION
Lamp Wattage
type
HM
Mains
Current
Temp. rise
Net
Circuit DimenEN 60922 weight Diag. sions
∆t (°C)
(kg)
No.
No.
12.8/10.0 0.50/0.42
65/55
1.22
15
20
14.5/11.5 0.55/0.50
70/60
1.22
15
20
BALLAST INFORMATION
COMPENSATION
Current
Ballast type
Voltage Parallel Ck
230/250V
±10%
Mains
Current
Power
losses
Inductive
(µF)
(A)
(W)1)
λ
(W)
(A)
80/50
0.80/0.62
E 80/50 LU
240
8.0
0.45/0.30
125/80
1.15/0.80
E 125/80 LU
240
10.0
0.70/0.45
Temp. rise
Net
Circuit DimenEN 60922 weight Diag. sions
∆t (°C)
(kg)
No.
No.
13.3/10.5 0.50/0.42
65/55
1.22
15
20
15.0/12.0 0.55/0.50
70/60
1.22
15
20
230/240V / 50Hz ballasts
LAMP INFORMATION
HM
Lamp Wattage
type
Current
(W)
(A)
125/80
1.15/0.80
BALLAST INFORMATION
COMPENSATION
Ballast type
E 125/80 ENK
Voltage Parallel Ck
230/250V
±10%
230/240
Power
losses
Inductive
(µF)
(A)
(W)1)
λ
∆t (°C)
(kg)
No.
No.
10.0/8.0
0.70/0.45
14.0/9.5
0.55/0.50
60
1.5
20
23
1) Winding at 25°C
DATA SUBJECT TO CHANGE WITHOUT NOTICE
T11 030 1A 23.10.2001
Temp. rise
Net
Circuit DimenEN 60922 weight Diag. sions
Mains
Current
4.3
Magnetic ballasts for HIGH PRESSURE MERCURY LAMPS
50 - 400W
220 / 230 / 240V 50Hz
• Meets EN60922 & EN60923 requirements
• Very low magnetic field
• 100% quality controlled
• Low power losses
• Low harmonics
• Low noise
• Long lifetime
• Multiple fixing point variations
• CE marked
LAMP INFORMATION
Mains
Current
Power
losses
Inductive
(µF)
(A)
(W)1)
λ
∆t (°C)
(kg)
No.
No.
220
230
240
7.0
0.3
11.0
11.3
11.6
0.42
70
1.22
21
20
E 80 LU
220
230
240
8.0
0.45
12.0
12.4
12.8
0.50
70
1.22
21
20
1.15
E 125 LU
220
230
240
10.0
0.7
13.5
14.0
14.7
0.55
70
1.22
21
20
250
2.15
E 250 EN
220
230
240
18.0
1.4
21.0
0.55
75
2.00
24
24
250
2.15
E 250 T,F2)
220
230
240
18.0
1.4
1.4
1.3
20.0
21.0
22.0
0.55
60
65
70
2.20
22
14,17
400
3.25
E 400 T,F2)
220
230
240
25.0
2.15
24.0
25.0
26.0
0.60
60
65
70
3.16
22
15,18
Wattage
Current
Ballast type
(W)
(A)
50
0.61
E 50 LU
80
0.80
125
HM
Lamp
type
BALLAST INFORMATION
COMPENSATION
Voltage Parallel Ck
230/250V
±10%
1) Winding at 25°C
2) T-type = two and four point fixing
F-type = four point fixing
DATA SUBJECT TO CHANGE WITHOUT NOTICE
T11 031 1A 23.10.2001
4.4
Temp. rise
Net
Circuit DimenEN 60922 weight Diag. sions
5
Magnetic ballasts for HIGH PRESSURE SODIUM LAMPS
35 -70W
230V 50Hz
• Meets EN60922 & EN60923 requirements
• Small size
• Double wire terminals without screws
• 100% quality controlled
• Long lifetime
• Very low magnetic field
• Low harmonics
• Low power losses
• CE marked
LAMP INFORMATION
Lamp Wattage
type
Current
BALLAST INFORMATION
COMPENSATION
Ballast type
Voltage Parallel Ck
230/250V
±10%
Mains
Current
Power
losses
Inductive
Temp. rise
Net
Circuit DimenEN 60922 weight Diag. sions
(µF)
(A)
(W)1)
λ
∆t (°C)
(kg)
No.
No.
(A)
35
0.53
NK 35 T62)
230
6.0
0.27
10.5
0.39
65
0.63
28
10
70
1.00
NK 70 T7
2)
230
12.0
0.43
16.0
0.39
70
1.15
28
12
HS
(W)
1) Winding at 25°C
2) For metal halide and HPS lamps (no thermal protector fitted)
DATA SUBJECT TO CHANGE WITHOUT NOTICE
T11 033 1A 23.10.2001
5.1
Magnetic ballasts for HIGH PRESSURE SODIUM LAMPS
35 - 1000W
230 / 240V 50Hz
• Meets EN60922 & EN60923 requirements
• Very low magnetic field
• 100% quality controlled
• Low power losses
• Low harmonics
• Low noise
• Long lifetime
• Multiple fixing point variations
• CE marked
LAMP INFORMATION
HS
Lamp
type
BALLAST INFORMATION
COMPENSATION
W attage
Current
(W)
(A)
35
0.49
NK 35 LUS3)
50
0.75
NK 50 LUS4)
50
0.75
NK 50 LU7)
70
1.0
NK 70 ENK7)
70
0.98
NK 70 LUK7)
70
1.0
NK 70 LU7)
70/50
1.0/0.75
NK 70/50 LU
70/50
1.0/0.75
NK 70/50 LUP
100
1.35
NK 100 LUS5)
100
1.2
NK 100 EN7)
100
1.2
NK 100 LU7)
100/70
1.2/1.0
NK 100/70 ENK
100/70
1.2/1.0
NK 100/70 EN
150
1.8
Ballast type
7)
NK 150 ENK7)
150
1.8
NK 150/2 LU2)7)
150
1.8
NK 150 T,F6)7)
150
1.8
NK 150 EN7)
150/100
1.8/1.2
NK150/100 EN
250
3.0
NK 250 T,F6)7)
400
4.4
NK 400 T,F6)7)
1000
10.3
NK 1000 EI
Voltage Parallel Ck
230/250V
±10%
230
240
230
240
230
240
230
240
230
240
230
240
230
240
230
230
240
230
240
230
240
230
240
230
240
230
240
230
240
230
240
230
240
230
240
230
240
230
240
230
240
Mains
Current
Power
losses
Inductive
(µF)
(A)
(W)1)
λ
6.0
0.27
8.0
0.33
8.0
0.33
12.0
0.43
12.0
0.43
12.0
0.43
12.0/8.0
0.43/0.33
12.0/8.0
0.43/0.33
16.0
0.60
12.0
0.56
12.0
0.56
12.0
0.56/0.43
12.0
0.56/0.43
20.0
1.1
20.0
1.1
1.0
20.0
1.1
20.0
1.1
20.0/12.0
1.1/0.56
32.0
1.4
50
2.2
100
5.3
5.0
1) Winding at 25°C
2) Type NK 150/2 LU contains two ballasts of the same type
3) For Philips SDW-T 35 W lamps (Ignitor CSL 35)
4) For Philips SDW-T 50 W lamps (Ignitor CSL 50)
DATA SUBJECT TO CHANGE WITHOUT NOTICE
T11 034 1A 23.10.2001
Temp. rise
Net Circuit DimenEN 60922 weight Diag. sions
∆t (°C)
(kg)
No.
No.
50
1.22
-
20
50
1.22
-
20
70
1.22
26
20
60
1.5
30
23
65
1.22
26
20
70
1.22
26
20
75/60
1.22
27
20
75/60
1.22
27
20
80
1.22
-
20
65
1.5
30
23
80
1.22
26
20
13.5/11.2 0.40/0.36
55/50
2.0
35
23
15.0/12.0 0.40/0.37
70/60
1.5
35
23
0.42
60
2.2
30
25
0.42
70
2.45
34
20
0.42
70
75
2.17
29
14,17
0.42
75
2.0
30
24
0.42/0.39
75/60
2.6
35
24
3.15
29
15,18
4.3
29
16,19
10.0
32
21
9.0
0.38
9.4
9.8
0.40
10.0
12.0
0.38
12.5
12.0
0.38
12.5
13.5
0.39
14.0
14.8
0.39
15.0
14.5/11.0
0.39/0.38
15.0/11.5
14.5/11.0
0.39/0.38
15.0/11.5
16.5
0.40
17.0
14.0
0.43
14.6
15.6
0.44
16.6
16.5
17.4
29.0
30.0
20.0
21.0
17.5
19.5
21/13
28
29
32
33
55
59
0.42
0.40
0.43
70
75
70
75
80
5) For Philips SDW-T 100 W lamps (Ignitor CSL 100)
6) T-type = two and four point fixing F-type = four point fixing
7) These ballasts can also be delivered with thermal protector.
In these cases the product type will be e.g NK 70 LUP 230/240V
5.2
Magnetic ballasts for HIGH PRESSURE SODIUM LAMPS
50 - 400W
220 / 230 / 240V 50Hz
• Meets EN60922 & EN60923 requirements
• Very low magnetic field
• 100% quality controlled
• Low power losses
• Low harmonics
• Low noise
• Long lifetime
• Multiple fixing point variations
• CE marked
LAMP INFORMATION
HS
Lamp
type
BALLAST INFORMATION
COMPENSATION
Parallel Ck
230/250V
±10%
Mains
Current
Power
losses
Inductive
Temp. rise
EN 60922
(µF)
(A)
(W)1)
λ
∆t (°C)
(kg)
No.
No.
220
230
240
8.0
0.33
11.5
12.0
12.5
0.38
70
1.22
31
20
220
230
240
12.0
0.43
14.5
14.8
15.0
0.39
70
1.22
31
20
2)
220
230
240
20.0
1.1
19.0
20.0
21.0
0.42
70
70
75
2.17
33
14,17
3.0
NK 250 T,F 2)
220
230
240
32.0
1.4
27
28
29
0.42
70
70
75
3.15
33
15,18
4.4
NK 400 T,F
2)
220
230
240
50
2.2
31
32
33
0.40
70
70
75
4.3
33
16,19
W attage
Current
Ballast type
(W)
(A)
50
0.76
NK 50 LU
70
1.0
NK 70 LU
150
1.8
NK 150 T,F
250
400
Voltage
1) Winding at 25°C
2) T-type = two and four point fixing F-type = four point fixing
DATA SUBJECT TO CHANGE WITHOUT NOTICE
T11 035 1A 23.10.2001
5.3
Net
Circuit Dimenweight Diag. sions
6
Magnetic ballasts for METAL HALIDE LAMPS
35 - 1000W
230 / 240V 50Hz
• Meets EN60922 & EN60923 requirements
• Very low magnetic field
• 100% quality controlled
• Low power losses
• Low harmonics
• Low noise
• Long lifetime
• Multiple fixing point variations
• CE marked
LAMP INFORMATION
HI
Lamp Wattage
type
Current
BALLAST INFORMATION
COMPENSATION
Ballast type
Voltage Parallel Ck
230/250V
±10%
Mains
Current
Power
losses
(µF)
(A)
(W)
λ
∆t (°C)
(kg)
No.
No.
1)
Induc- tive Temp. rise Net
EN 60922 weight
Circuit DimenDiag. sions
(W)
(A)
35
0.53
NK 35 LUP 3)
230
240
6.0
0.27
9.0
9.4
0.38
50
1.22
39
20
35
0.53
NK 35 T6
230
6.0
0.27
10.5
0.39
65
0.63
42
10
70/50
1.0/0.75
NK 70/50 LUP
230
12.0/8.0
0.43/0.33
75/60
1.22
37b
20
70
1.0
NK70 ENPK
12.0
0.43
60
1.5
38
23
70
0.98
NK 70 LUPK
12.0
0.43
65
1.22
37a
20
70
1.0
NK 70 LUP
12.0
0.43
70
1.22
37a
20
70
1.00
NK 70 T7
12.0
0.43
0.39
70
1.15
42
12
100
1.2
NK 100 ENP
12.0
0.56
0.42
65
1.5
38
23
100
1.1
NK 100 LUP
12.0
0.56
0.44
80
1.22
37a
20
150
1.8
NK 150 ENPK
20.0
1.1
2.2
38
25
150
1.8
NK 150 TP, FP
20.0
1.1
2.17
41
14,17
150
1.8
NK 150 ENP
20.0
1.1
2.0
38
24
250
3.0
NK 250 TP,FP
32.0
1.4
3.15
41
15,18
3.18
40
15,17
400
3.5
H 400 T,F 2)4)
400
3.5
E 400 T,F 2)4)
1000
9.5
H 1000 EI
230
240
230
240
230
240
230
230
240
230
240
230
240
230
240
230
240
230
240
230
240
230
240
230
240
35
2.2
35
2.15
100
4.6
1) Winding at 25°C
2) T-type = two and four point fixing
F-type = four point fixing
3) No thermal protector inside
4) Available with thermal switch
DATA SUBJECT TO CHANGE WITHOUT NOTICE
T11 037 1A 25.7.2002
6.1
14.5/11.0
0.39/0.38
15.0/11.5
12.0
0.38
12.5
13.5
0.39
14.0
14.8
0.39
15.0
16.0
14.0
14.6
15.6
16.6
16.5
17.4
20
21
17.5
18.5
28
29
24.9
26
25
26
56
60
0.50
0.48
60
65
70
75
75
80
70
75
70
75
0.60
80
3.16
40
15,17
0.47
75
10.0
43
21
0.40
0.42
0.42
0.42
7
ELECTRONIC SUPERIMPOSED PULSE IGNITORS
WITHOUT TIMER
220-240V 50/60Hz
• Fully electronic
• Super-imposed pulse type
• Compact design
• Solid metal fixing screw
• Low inherent heating
• High thermal resistance
• Low power losses
• ENEC approved
• CE marked
Light source:
L-70
L-150
HI-400S
L-1000
HS lamps
(W)
35-70
100-150
100-400
100-1000
HI lamps
(W)
-
35-150
70-400
70-1000
Max. contin. lamp current
(A)
1
1.8
4.6
12
Operating voltage
(V)
198-264
198-264
198-264
198-264
Cut-out voltage
(V)
≤ 170
≤ 170
≤ 170
≤ 170
Ignition voltage
(kV)
1.9 ... 2.3
4.0 ... 4.5
4.0 ... 4.5
4.0 ... 4.5
Impulse width
(µs)
2 (1.5 kV)
1.4 (2.0 kV)
1.0 (2.0 kV)
1.7 (2.5 kV)
Phasing
(°el)
60-90 / 240-270
60-90 / 240-270
60-90 / 240-270
60-90 / 240-270
2
3
3
3
Pulses per half cycle
Max. load capacitance
(pF)
200
100
100
100
Internal losses
(W)
< 1.0 (25°C; 1A)
< 1.0 (25°C; 1.8A)
< 3.3 (25°C; 4.6A)
< 6.0 (25°C; 12A)
Max. housing temperature
(°C)
105
105
105
105
Min. ambient temperature
(°C)
-30
-30
-30
-30
Weight
(g)
105
128
150
450
Dimensions AxBxC
(mm) 88x34x28
88x34x28
92x39x33
108x55x43
Terminals: 3-pole B-Lp-N 2.5 mm 2 max
L1
C
D
M8
L
B
10
Ignitor
A
N
DATA SUBJECT TO CHANGE WITHOUT NOTICE
T17 007 1A 23.10.2001
7.1
N
ELECTRONIC SUPERIMPOSED PULSE IGNITORS
WITH TIMER
220-240V 50/60Hz
• Fully electronic
• Super-imposed pulse type
• Compact design
• Solid metal fixing screw
• Low inherent heating
• High thermal resistance
• Low power losses
• ENEC approved
• CE marked
LSI-150T20
LHI-400ST10
LSI-1000T10
(W) 35-70
LSI-70T1
100-150
100-400
100-1000
(W) -
35-150
70-400
70-1000
1
1.8
4.6
12
Cut out time
(min) 2
20
16
18
Operating voltage
(V)
198-264
198-264
198-264
198-264
Cut-out voltage
(V)
≤ 170
≤ 170
≤ 170
≤ 170
Ignition voltage
(kV) 1.9 ... 2.3
4.0 ... 4.5
3.5 ... 4.5
4.0 ... 4.5
Impulse width
(µs) 2 (1.5 kV)
1.4 (2.0 kV)
1.0 (2.0 kV)
1.7 (2.5 kV)
Phasing
(°el) 60-90 / 240-270
60-90 / 240-270
60-90 / 240-270
60-90 / 240-270
3
3
3
Light source: HS lamps
HI lamps
Max. contin. lamp current (A)
Pulses per half cycle
2
Max. load capacitance
(pF) 200
100
100
100
Internal losses
(W) <1.0 (25°C; 1A)
<1.0 (25°C;1.8A)
<3.0 (25°C; 4.6A)
<6.0 (25°C; 12A)
Max. housing temp.
(°C) 105
105
105
105
Min. ambient temp.
(°C) -30
-30
-30
-30
Weight
(g)
128
184
450
Dimensions AxBxC
(mm) 88x34x28
88x34x28
92x39x33
108x55x43
105
Terminals: 3-pole B-Lp-N 2.5 mm 2 max
L1
C
D
M8
L
B
10
Ignitor
A
N
DATA SUBJECT TO CHANGE WITHOUT NOTICE
T17 008 1A 23.10.2001
7.2
N
HELVAR IGNITORS FOR HIGH PRESSURE SODIUM- AND METAL HALIDE LAMPS
HIGH PRESSURE SODIUM
Ignitor
Watt
35
50
70
100 150 250 400 1000
CERAMIC METAL HALIDE
35
L-70
LSI-70T1
L-150
LSI-150T20
HI-400S
LHI-400ST10
L-1000
LSI-1000T10
Recommended combination
T1
T10
T20
Automatic cut-out 2 min
Automatic cut-out 18 min
Automatic cut-out 20 min
DATA SUBJECT TO CHANGE WITHOUT NOTICE
T17 006 1B 13.6.2002
7.3
70
100
150
METAL HALIDE
35
70
100 150 250 400 1000
8
Electronic ballasts for FLUORESCENT T5 LAMPS
14-54W
Standard
220-240V 50-60Hz
• 21 or 28 mm high
• Optimal lamp operation
• Wide operational ambient temperature range
• Flickerless light
• Low power losses
• Silent operation
• Stabilized output
• Low harmonics
• High power factor
Lamp
type
W
14
21
T5
24
28
35
39
49
54
80
No. of
lamps
Ballast
1
1
2
2
3
3
4
4
1
1
2
2
1
1
2
2
1
1
2
2
1
1
2
2
1
1
2
2
1
1
2
2
1
1
2
2
EL 1x14-35s
EL 1x14 HFT5
EL 2x14-35s
EL 2x14 HFT5
EL 3/4x14s
EL 3x14 HFT5
EL 3/4x14s
EL 4x14 HFT5
EL 1x14-35s
EL 1x21 HFT5
EL 2x14-35s
EL 2x21 HFT5
EL 1x24s
EL 1x24 HFT5
EL 2x24s
EL 2x24 HFT5
EL 1x14-35s
EL 1x28 HFT5
EL 2x14-35s
EL 2x28 HFT5
EL 1x14-35s
EL 1x35 HFT5
EL 2x14-35s
EL 2x35 HFT5
EL 1x39s
EL 1x39 HFT5
EL 2x39s
EL 2x39 HFT5
EL 1x49s
EL 1x49 HFT5
EL 2x49s
EL 2x49 HFT5
EL 1x54s
EL 1x54 HFT5
EL 2x54s
EL 2x54 HFT5
1
EL 1x80s
Circuit
power
Mains
current
(W)
(A)
(kHz)
16
17
31
32
47
50
62
64
23
24
45
46
25
26
49
51
30.5
31
60
63
38
38
76
80
42
42
84
82
53
54
105
105
58
59
116
115
0.08-0.07
0.08-0.07
0.15-0.13
0.16-0.15
0.22-0.19
0.23-0.20
0.29-0.26
0.29-0.26
0.11-0.10
0.11-0.10
0.20-0.18
0.21-0.20
0.13-0.12
0.14-0.12
0.24-0.21
0.24-0.21
0.14-0.13
0.15-0.13
0.27-0.25
0.28-0.27
0.18-0.16
0.18-0.16
0.34-0.31
0.35-0.34
0.20-0.18
0.20-0.18
0.36-0.33
0.36-0.33
0.25-0.23
0.25-0.23
0.50-0.46
0.50-0.46
0.26-0.24
0.26-0.24
0.53-0.48
0.53-0.49
46
29
46
27
46
28
46
28
46
26
46
36
59
26
59
29
46
25
46
32
46
26
46
32
53
24
53
24
27
26
27
25
42
25
42
25
85
0.37-0.34
45
DATA SUBJECT TO CHANGE WITHOUT NOTICE
T07 067 1B 4.12.2001
8.1
Operating EEI
frequency
Lamp
power
Weight
Wiring
Dimensions
(W)
(g)
no.
no.
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
14
14
14
14
14
14
14
14
21
21
21
21
22.5
24
22.5
24
28
28
28
28
35
35
35
35
39
39
39
39
49
49
49
49
54
54
54
54
215
270
285
340
285
400
285
400
215
270
285
340
215
270
285
340
215
270
285
340
215
270
285
340
215
270
285
340
215
270
285
340
215
270
285
340
64
64
65
65
66b
66a
67
67
64
64
65
65
64
64
65
65
64
64
65
65
64
64
65
65
64
64
65
65
64
64
65
65
64
64
65
65
29
26
30
27
30
28
30
28
29
26
30
27
29
26
30
27
29
26
30
27
29
26
30
27
29
26
30
27
29
26
30
27
29
26
30
27
A2
80
215
64
29
Electronic ballasts for FLUORESCENT T5 LAMPS
28-35W
Controllable
220-240V 50-60Hz
• Dimming range 3-100%
• Energy saving
• Starting at any dimmed level without flicker
• Low weight
• Flickerless light
• Covers EMC requirements
• Low harmonics
• Stabilized output
• 28 mm high
T5
Lamp
type
W
28
35
No. of
lamps
1
2
1
2
Ballast
Circuit
power
Mains
current
(W)
(A)
(kHz)
33
63
40
78
0.15-0.13
0.29-0.28
0.19-0.17
0.36-0.33
45 - 75
45 - 75
45 - 75
45 - 75
EL 1x28 HFCT5
EL 2x28 HFCT5
EL 1x35 HFCT5 *
EL 2x35 HFCT5 *
* Dimming range 15-100% if Ta < 20°C
DATA SUBJECT TO CHANGE WITHOUT NOTICE
T07 068 1A 1.11.2001
8.2
Operating EEI
frequency
A1
A1
A1
A1
Lamp
power
Weight
Wiring
Dimensions
(W)
(g)
no.
no.
28
28
35
35
320
400
320
400
68
69
68
69
34
35
34
35
Electronic ballasts for FLUORESCENT T5 LAMPS
28-35W
•
Digital
220-240V 50-60Hz
protocol
• Microprocessor controlled
• Dimming range 3-100%
• Low weight
• Flickerless light
• Energy saving
• Stabilized output
• Starting at any dimmed level without flicker
• 28 mm high
T5
Lamp
type
W
28
35
No. of
lamps
1
2
1
2
Ballast
Circuit
power
Mains
current
(W)
(A)
(kHz)
33
63
40
78
0.16-0.14
0.29-0.27
0.19-0.17
0.36-0.33
> 45
> 45
> 45
> 45
EL 1x28 HFIT5
EL 2x28 HFIT5
EL 1x35 HFIT5 *
EL 2x35 HFIT5 *
* Dimming range 15-100% if Ta < 20°C
DATA SUBJECT TO CHANGE WITHOUT NOTICE
T07 069 1B 10.12.2001
8.3
Operating EEI
frequency
A1
A1
A1
A1
Lamp
power
Weigth
Wiring
Dimensions
(W)
(g)
no.
no.
28
28
35
35
320
400
320
400
70
71
70
71
36
37
36
37
9
Electronic ballasts for FLUORESCENT T8 LAMPS
18-70W
Standard
220-240V 50-60Hz
• Energy saving
• Warm Start according to lamp standards
• Low weight
• Flickerless light
• Covers EMC requirements
• Low harmonics
• Low power losses
• Stabilized output
• 28 mm high
Lamp
type
W
T8
18
32
36
58
70
No. of
lamps
1
2
3
4
2
1
2
1
2
1
2
Ballast
EL 1x18 HF
EL 2x18 HF
EL 3x18 HF
EL 4x18 HF
EL 2x32 HF
EL 1x36 HF 1)
EL 2x36 HF 1)
EL 1x58 HF 1)
EL 2x58 HF 1)
EL 1x70 HF
EL 2x70 HF
Circuit
power
(W)
Mains
current
(A)
19
36
55
74
73
36
70
56
108
66
133
0.09-0.08
0.16-0.15
0.26-0.24
0.34-0.31
0.34-0.31
0.16-0.15
0.32-0.29
0.26-0.23
0.49-0.45
0.29-0.28
0.59-0.54
1) Also available with side mounted case
DATA SUBJECT TO CHANGE WITHOUT NOTICE
T07 063 1A 22.10.2001
9.1
Operating EEI
frequency
(kHz)
26
27
30
30
23
26
60
27
44
27
27
A2
A2
A3
A3
A3
A3
A3
A3
A3
A3
Lamp
power
(W)
Weight
Wiring
(g)
no.
Dimensions
no.
16
16
16
16
32
32
32
50
50
60
60
270
340
400
400
340
270
340
270
340
270
340
45
46
47
48
46
45
46
45
46
45
46
26
27
28
28
27
26
27
26
27
26
27
Electronic ballasts for FLUORESCENT T8 LAMPS
18-70W
Controllable
230-240V 50-60Hz
• Dimming range 5-100%
• Energy saving
• Starting at any dimmed level without flicker
• Low weight
• Flickerless light
• Covers EMC requirements
• Low harmonics
• Stabilized output
• 28mm high
Lamp
type
W
No. of
lamps
T8
18
36
58
70
1
2
1
2
1
2
1
Ballast
EL 1x18 HFC
EL 2x18 HFC
EL 1x36 HFC
EL 2x36 HFC
EL 1x58 HFC
EL 2x58 HFC *
EL 1x70 HFC
Circuit
power
Mains
current
(W)
(A)
(kHz)
20
38
38
72
58
113
68
0.10-0.08
0.19-0.17
0.18-0.16
0.35-0.31
0.27-0.25
0.56-0.50
0.32-0.29
32-70
34-62
40-70
30-60
40-70
30-80
30-70
* 220-240V 50-60Hz
DATA SUBJECT TO CHANGE WITHOUT NOTICE
T07 065 1A 22.10.2001
9.2
Operating EEI
frequency
A1
A1
A1
A1
A1
A1
A1
Lamp
power
Weight
Wiring
Dimensions
(W)
(g)
no.
no.
16
16
32
32
50
50
60
320
400
320
400
320
400
320
49
50
49
50
49
50
49
34
35
34
35
34
35
34
10
Electronic ballasts for COMPACT LAMPS
9-55W
Standard
220-240V 50-60Hz
• Energy saving
• Warm start according to lamp standards
• Low weight
• Flickerless light
• Covers EMC requirements
• Low harmonics
• Low power losses
• Stabilized output
• Low earth leakage current
Lamp
type
W
No. of
lamps
18
TC-L
24
34
36
40
55
TC-F
18
24
36
TC-DE
10
13
18
26
1
2
1
2
1
2
1
1
2
1
1
2
1
2
1
1
2
1
2
1
1
2
2
1
2
1
2
1
2
1
2
Ballast
EL 1x18-42 CHF
EL 2x18-40 CHF
EL 1x18-42 CHF
EL 2x18-40 CHF
EL 1x36 HF
EL 2x36 HF2F*
EL 1x18-42 CHF
EL 1x36 HF
EL 2x36 HF2F*
EL 1x18-42 CHF
EL 1x36 HF
EL 2x36 HF2F*
EL 1x55 HF2F
EL 2x55 HF2F*
EL 1x18 HF
EL 1x18-42 CHF
EL 2x18-40 CHF
EL 1x18-42 CHF
EL 2x18-40 CHF
EL 1x36 HF
EL 1x18-42 CHF
EL 2x36 HF
EL 2x36 HF2F*
EL 1x9-13 CHF
EL 2x10/13 CHF
EL 1x9-13 CHF
EL 2x10/13 CHF
EL 1x18 CHF
EL 2x18 CHF
EL 1x18-42 CHF
EL 2x18-40 CHF
Circuit
power
Mains
current
(W)
(A)
(kHz)
19
36
25
50
35
73
37
36
74
44
39
89
63
125
17.5
19
36
25
50
36
37
71
74
12
23
15
30
20
40
27
55
0.08
0.16
0.11
0.22
0.15
0.30
0.16
0.15
0.31
0.19
0.15
0.40
0.27
0.55
0.08
0.08
0.16
0.11
0.22
0.15
0.16
0.30
0.31
0.06
0.10
0.07
0.13
0.09
0.17
0.12
0.24
40-50
40-50
40-50
40-50
26
25
40-50
26
25
40-50
26
25
28
25
26
40-50
40-50
40-50
40-50
26
40-50
60
25
40-50
36-50
40-50
36-50
40-50
40-50
40-50
40-50
*230-240V 50-60Hz
DATA SUBJECT TO CHANGE WITHOUT NOTICE
T07 073 1A 1.11.2001
10.1
Operating EEI
frequency
A2
A2
A2
A2
A2
A3
A2
A2
A2
A3
A3
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
Lamp
power
Weight
Wiring
Dimensions
(W)
(g)
no.
no.
16
16
23
23
31
32
30
32
32
40
34
40
55
55
15
16
16
23
22
32
31
32
32
10
10
13
13
18
18
25
25
150
200
150
200
270
340
150
270
340
150
270
340
270
340
270
150
200
150
200
270
150
340
340
150
190
150
190
150
190
150
200
57
58
57
58
55
56
57
55
56
57
55
56
55
56
55
57
58
57
58
55
57
56
56
57
58
57
58
57
58
57
58
31
32
31
32
26
27
31
26
27
31
26
27
26
27
26
31
32
31
32
26
31
27
27
31
32
31
32
31
32
31
32
Electronic ballasts for COMPACT LAMPS
9-55W
TC-SE
Lamp
type
W
TC-TE
Ballast
220-240V 50-60Hz
Circuit
power
Mains
current
Operating EEI
frequency
(W)
(A)
(kHz)
Lamp
power
Weight
Wiring
(W)
(g)
no.
Dimensions
no.
no.
1
2
1
EL 1x9-13 CHF
EL 2x10/13 CHF
EL 1x9-13 CHF
10
20
13
0.05
0.09
0.06
40-50
36-50
40-50
-
9
9
11
150
190
150
57
58
57
31
32
31
2
1
2
1
2
1
2
1
1
2
EL 2x10/13 CHF
EL 1x9-13 CHF
EL 2x10/13 CHF
EL 1x18 CHF
EL 2x18 CHF
EL 1x18-42 CHF
EL 2x18-40 CHF
EL 1x18-42 CHF
EL 2x18-40 CHF
EL 1x18-42 CHF
EL 2x42 CHF
26
15
30
20
40
27
55
37
73
48
94
0.12
0.07
0.13
0.09
0.17
0.12
0.24
0.16
0.32
0.21
0.41
36-50
40-50
36-50
40-50
40-50
40-50
40-50
40-50
40-50
40-50
42-52
A2
A2
A2
A2
A2
A2
A2
A2
11
13
13
16
16
24
25
32
32
44
44
190
150
190
150
190
150
200
150
200
150
360
58
57
58
57
58
57
58
57
58
57
55
32
31
32
31
32
31
32
31
32
31
33
1
EL 1x18 HF
20
0.11
26
-
17
270
55
26
1
EL 1x36 HF
38
0.17
26
-
33
270
55
26
1
EL 1x55 HF2F
60
0.22
28
-
45
270
55
26
22
1
EL 1x18-42 CHF
25
0.11
40-50
A2
23
150
57
31
2
EL 2x18-40 CHF
36
0.16
40-50
A2
22
200
58
32
40
1
EL 1x18-42 CHF
44
0.19
40-50
A2
38
150
57
31
2 1) EL 2x18-40 CHF
71
0.31
40-50
A2
22 / 39
200
58
32
9
11
13
18
26
32
42
TC-T5C TC-DD
No. of
lamps
Standard
21
38
55
1) One 22 watt lamp and one 40 watt lamp
DATA SUBJECT TO CHANGE WITHOUT NOTICE
T07 073 1A 1.11.2001
10.2
Electronic ballasts for COMPACT LAMPS
10-55W
Controllable
220-240V 50-60Hz
• Warm start according to lamp standards
• Energy saving
• Dimming range 5-100%
• Low weight
• Flickerless light
• Covers EMC requirements
• Low harmonics
• Stabilized output
• Low earth leakage current
Lamp
type
W
TC-L
TC-F
TC-DE *
Ballast
1
2
1
2
1
2
EL 1x18 CHFC-L/F
EL 2x18 CHFC-L/F
EL 1x24 CHFC-L/F
EL 2x24 CHFC-L/F
EL 1x36 HFC2F
EL 2x36 HFC2F
1
EL 1x40 HFC2F
32
1
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
EL 1x55 HFC2F
EL 1x18 CHFC-L/F
EL 2x18 CHFC-L/F
EL 1x24 CHFC-L/F
EL 2x24 CHFC-L/F
EL 1x10/13 CHFC
EL 2x10/13 CHFC
EL 1x10/13 CHFC
EL 2x10/13 CHFC
EL 1x18 CHFC
EL 2x18 CHFC
EL 1x26 CHFC
EL 2x26 CHFC
EL 1x10/13 CHFC
EL 2x10/13 CHFC
EL 1x18 CHFC
EL 2x18 CHFC
EL 1x26 CHFC
EL 2x26 CHFC
EL 1x32 CHFC
EL 2x32 CHFC
42
1
EL 1x42 CHFC
18
24
36
40
55
18
24
10
13
18
26
13
TC-TE *
No. of
lamps
18
26
Circuit
power
Mains
current
Lamp
power
Weight
Wiring
Dimensions
(W)
(A)
(kHz)
(W)
(g)
no.
no.
20.5
37
27
50
37
72
0.09
0.17
0.12
0.22
0.17
0.32
40-100
40-120
40-100
40-120
40-56
40-74
A1
A1
A1
A1
A1
A1
17.5
17
23.5
23
32
32
210
360
210
360
320
400
62
63
62
63
60
61
32
33
32
33
34
35
44
0.20
45-73
A1
40
320
60
34
64
20.5
37
27
50
11.5
23
15.5
29
21
39
29
56
15.5
29
21
39
29
56
37
72
0.28
0.09
0.17
0.12
0.22
0.05
0.10
0.07
0.13
0.10
0.17
0.13
0.24
0.07
0.13
0.10
0.17
0.13
0.24
0.16
0.31
40-70
40-100
40-120
40-100
40-120
45-90
50-100
45-90
50-100
45-90
40-80
40-100
30-80
45-90
50-100
45-90
40-80
40-100
30-80
40-100
30-80
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
55
17.5
17
23.5
23
9.5
9.5
12.5
11.5
17.5
17.5
25.5
25.5
12.5
13
18
17
25.5
25.5
33
33
320
210
360
210
360
190
340
190
340
210
360
190
360
190
340
210
360
190
360
220
380
60
62
63
62
63
62
63
62
63
62
63
62
63
62
63
62
63
62
63
62
63
34
32
33
32
33
32
33
32
33
32
33
32
33
32
33
32
33
32
33
32
33
48
0.21
45-85
A1
43
220
62
32
* Dimming range 10-100%
DATA SUBJECT TO CHANGE WITHOUT NOTICE
T07 074 1A 1.11.2001
10.3
Operating EEI
frequency
11
Wiring diagrams of MAGNETIC BALLASTS for FLUORESCENT T8 and UV LAMPS
1
2
3
4
5
DATA SUBJECT TO CHANGE WITHOUT NOTICE
T10 126 1A 23.10.2001
11.1
Wiring diagrams of MAGNETIC BALLASTS for COMPACT FLUORESCENT LAMPS
7
8
9
10
11
12
13
13a
L
N
DATA SUBJECT TO CHANGE WITHOUT NOTICE
T10 127 1A 23.10.2001
11.2
Wiring diagrams of MAGNETIC BALLASTS for HIGH PRESURE MERCURY LAMPS
14
15
16
17
18
19
20
21
22
23
24
DATA SUBJECT TO CHANGE WITHOUT NOTICE
T11 032 1A 23.10.2001
11.3
Wiring diagrams of MAGNETIC BALLASTS for HIGH PRESURE SODIUM LAMPS
26
27
28
29
30
31
32
33
34
35
DATA SUBJECT TO CHANGE WITHOUT NOTICE
T11 036 1A 23.10.2001
11.4
Wiring diagrams of MAGNETIC BALLASTS for METAL HALIDE LAMPS
37a
37b
38
39
40
41
42
43
DATA SUBJECT TO CHANGE WITHOUT NOTICE
T11 038 1A 23.10.2001
11.5
12
Wiring diagrams of ELECTRONIC BALLASTS for T8 LAMPS
Standard
45
46
47
L
N
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
48
NOTE:
All wiring to the connectors marked with a black dot;
• (hot wires) shoul be as short as possible.
DATA SUBJECT TO CHANGE WITHOUT NOTICE
T07 075 1A 1.11.2001
12.1
Wiring diagrams of ELECTRONIC BALLASTS for T8 LAMPS
Controllable
49
1-10 VDC
control
< 1mA
50
1-10 VDC
control
< 1mA
L
N
C1 +
C0 -
1
2
3
4
5 9
6 10
7 11
8 12
13
14
15
16
NOTE:
All wiring to the connectors marked with a black dot;
• (hot wires) shoul be as short as possible.
DATA SUBJECT TO CHANGE WITHOUT NOTICE
T07 075 1A 1.11.2001
12.2
Wiring diagrams of ELECTRONIC BALLASTS for COMPACT LAMPS
Standard
55
56
57
58
59
NOTE:
All wiring to the connectors marked with a black dot;
• (hot wires) shoul be as short as possible.
In 57, 58 and 59 hot wires are marked to the ballast case
DATA SUBJECT TO CHANGE WITHOUT NOTICE
T07 076 1A 23.10.2001
12.3
Wiring diagrams of ELECTRONIC BALLASTS for COMPACT LAMPS
Controllable
60
1-10 VDC
control
< 1mA
61
1-10 VDC
control
< 1mA
62
63
1-10 VDC
control
< 0.8mA
1-10 VDC
control
< 0.8mA
NOTE:
All wiring to the connectors marked with a black dot;
• (hot wires) shoul be as short as possible.
In 62 and 63 hot wires are marked to the ballast case
DATA SUBJECT TO CHANGE WITHOUT NOTICE
T07 076 1A 23.10.2001
12.4
Wiring diagrams of ELECTRONIC BALLASTS for T5 LAMPS
Standard
64
65
66a
L
N
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
66b
67
NOTE:
All wiring to the connectors marked with a black dot;
• (hot wires) shoul be as short as possible.
DATA SUBJECT TO CHANGE WITHOUT NOTICE
T07 077 1B 4.12.2001
12.5
Wiring diagrams of ELECTRONIC BALLASTS for T5 LAMPS
Controllable
68
1-10 VDC
control
< 1mA
69
1-10 VDC
control
< 1mA
NOTE:
All wiring to the connectors marked with a black dot;
• (hot wires) shoul be as short as possible.
DATA SUBJECT TO CHANGE WITHOUT NOTICE
T07 077 1B 4.12.2001
12.6
Wiring diagrams of ELECTRONIC BALLASTS for T5 LAMPS
Digital
70
DALI input + Power supply
1-10 VDC
control < 1mA
DALI input
71
DALI input + Power supply
1-10 VDC
control < 1mA
DALI input
NOTE:
All wiring to the connectors marked with a black dot;
• (hot wires) shoul be as short as possible.
DATA SUBJECT TO CHANGE WITHOUT NOTICE
T07 077 1B 4.12.2001
12.7
13
Dimensions of MAGNETIC BALLASTS
Ballasts for Fluorescent, Compact fluorescent and UV-Suntanning lamps
DIMENSION NO.
DRAWING
LENGTH 'a' (mm)
WIDTH 'b' (mm)
HEIGHT 'c' (mm)
'd' (mm)
'e' (mm)
1
2
3
4
5
6
7
8
9
1
150
42
28
140
1
190
42
28
180
2
150
42
28.8
140
2
230
42
28.8
220
2
190
42
28.8
180
2
110
42
28.8
100
2
115
42
28.8
105
3
85
41,5
28
73
4
133
66
53
120
52
1
2
3
4
DATA SUBJECT TO CHANGE WITHOUT NOTICE
T10 128 1A 23.10.2001
13.1
Dimensions of MAGNETIC BALLASTS
High pressure discharge lamps
DIMENSION NO. 10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
DRAWING 1
LENGTH 'a' (mm) 125
WIDTH 'b' (mm) 42
HEIGHT 'c' (mm) 28.8
'd' (mm) 115
'e' (mm)
'f' (mm)
'g' (mm)
1
150
42
28.8
140
1
190
42
28.8
180
1
230
42
28.8
220
2
135
70
85
120
35
85
2
135
70
85
120
35
108
2
165
70
85
150
35
138
3
104
70
85
90
90
85
80
3
104
70
85
90
90
108
80
3
135
70
85
100
100
138
90
4
114
54
45,5
95
5
196
105
90
180
75-82
6
84
66
53
71
52
6
111
66
53
98
52
6
133
66
53
120
52
6
160
66
53
147
52
1
2
T-type
4
3
5
6
DATA SUBJECT TO CHANGE WITHOUT NOTICE
T11 027 1A 23.10.2001
13.2
F-type
14
Dimensions of STANDARD ELECTRONIC BALLASTS
DIMENSION NO
26
27
28
29
30
31
32
33
DRAWING
LENGTH 'a' (mm)
WIDTH 'b' (mm)
HEIGHT 'c' (mm)
'd' (mm)
'e' (mm)
'f' (mm)
'g' (mm)
1
280
30
28
270
270
1
360
30
28
350
350
1
430
30
28
420
420
2
280
30
21
270
270
2
360
30
21
350
350
3
103
67
30
110
83,5
57,5
93,5
3
123
79
33
129,5
99
67
111
3
158
102
38
171,5
134
90
146
1
CLASSIC CASE
SIDE MOUNT CASE
2
e
c
a
3
DATA SUBJECT TO CHANGE WITHOUT NOTICE
T07 070 1A 22.10.2001
14.1
Dimensions of CONTROLLABLE ELECTRONIC BALLASTS
DIMENSION NO.
DRAWING
LENGTH 'a' (mm)
W IDTH 'b' (mm)
HEIGHT 'c' (mm)
'd' (mm)
'e' (mm)
'f' (mm)
'g' (mm)
32
33
34
35
1
123
79
33
129,5
99
67
111
1
158
102
38
171,5
134
90
146
2
360
30
28
350
350
2
430
30
28
420
420
1
2
CLASSIC CASE
SIDE MOUNT CASE
DATA SUBJECT TO CHANGE WITHOUT NOTICE
T07 071 1A 22.10.2001
14.2
Dimensions of DIGITAL ELECTRONIC BALLASTS
DIMENSION NO. 36
DRAWING
LENGTH 'a' (mm)
W IDTH 'b' (mm)
HEIGHT 'c' (mm)
'd' (mm)
'e' (mm)
1
1
360
30
28
350
350
37
1
430
30
28
420
420
CLASSIC CASE
SIDE MOUNT CASE
DATA SUBJECT TO CHANGE WITHOUT NOTICE
T07 072 1A 22.10.2001
14.3
15
CHARACTERISTICS OF ELECTRONIC BALLASTS FOR T5 LAMPS
Technical values
Max.temperature at tc point
EL-s
EL-HFT5
EL-HFCT5
EL-HFIT5
80°C
80°C
80°C
80°C
Ambient temperature range
-20…+50°C
0…+50°C
+10…+50°C
+10…+50°C
Storage temperature range
-40…+80°C
-40…+80°C
-40…+80°C
-40…+80°C
Maximum relative humidity
no condensation
no condensation
no condensation
no condensation
Number of starts per lamp
>25 000
> 25 000
>20 000
> 20 000
Mains voltage tolerance
±10 %
±10 %
±10 %
±10 %
DC range
200 - 300 VDC
200 - 300 VDC
200 - 300 VDC
200 - 300 VDC
Over voltage duration
300 VAC
300 VAC
320 VAC, 1h
320 VAC, 1h
Power factor (at maximum)
0.98
0.98
0.98
0.98
Earth leakage current
< 0.4 mA
< 0.4 mA
< 0.4 mA
< 0.4 mA
Maximum working voltage (Uout)
Lifetime
-
-
-
500 V
90 000 h,
at 60°C Tc
90 000 h,
at 60°C Tc
90 000 h,
at 60°C Tc
90 000 h,
at 60°C Tc
2m
2m
2 m
2m
EL-s
EL-HFT5
EL-HFCT5
EL-HFIT5
X
X
X
X
X
X
X
X
Max length of ballast to lamp wiring
Standards
CE marked
General and safety requirements
EN 60928
Performance requirements
EN 60929 X
X
X
X
Lamp life acc. to
EN 60081 X
X
X
X
Warm start acc. to
EN 60929 X
X
X
X
EN 61000-3-2
X
X
X
X
Radio Frequency Interference, acc. to EN 55015
Mains current harmonics, acc. to
X
X
X
X
Immunity standard, acc. to
EN 61547
X
X
X
X
Vibration test
EN 60068-2-64 test Fh
X
X
X
X
Bump test
EN 60068-2-29 test Eb
X
X
X
X
VDE 0108 X
X
X
X
X
-
-
Can be used on DC, acc. to
Thermal protection class
EN 60928, B.5e
X
DATA SUBJECT TO CHANGE WITHOUT NOTICE
T070811A 3.12.2001
15.1
CHARACTERISTICS OF ELECTRONIC BALLASTS FOR T8 LAMPS
Technical values
EL-HF
EL-HFC
Max. temperature at tc point
80 °C
75/80 °C
Ambient temperature range
-20...+50°C 1)
0…+50 °C 6)
Storage temperature range
-40...+80 °C
-40...+80 °C
Maximum relative humidity
no condensation
no condensation
Number of starts per lamp
> 50 000
>20 000
Mains voltage tolerance
±10 %
±10 %
DC range
180 - 300 VDC
180 - 300 VDC
Over voltage
320 VAC, 1 h
300 VAC
Power factor (at maximum)
0.98
0.98
Earth leakage current
< 0.5 mA
< 0.5 mA
Maximum working voltage (r.m.s.) U-out
300 VAC
-
Lifetime
90 000h, at 60°C Tc
90 000h, at 50°C Tc
Max length of ballast to lamp wiring
< 2m
< 2m
EL-HF
EL-HFC
X
X
Standards
CE marked
General and safety requirements
EN 60928
X
X
Performance requirements
EN 60929
X
X 3)
Lamp life according to
EN 60081
X
X
2)
Warm start acc. to
EN 60929
X
X
Mains current harmonics acc. to
EN 61000-3-2 X
X
Radio Frequency Interference acc. to
EN 55015
X
X
Immunity standard acc. to
EN 61547
X
X 4)
Vibration test
EN 60068-2-64 test Fh
X
X
Bump test
EN 60068-2-29 test Eb
X
X
X
X
Can be used on DC, acc. to
VDE 0108
Thermal protection acc. to EN60928 B.5e
X 5)
1) 0...+50°C for 32W, 70W, 3x18W & 4x18W
2) 3x18 W, 4x18 W and 70 W. Warm start acc. to Helvar standard
3) 70W meets most requirements in EN 60929
4) Not EL-HFC 70W
5) Not EL 2x18 HF, EL 2x32 HF, EL 3x18 HF, EL 4x18 HF
6) 70W +15 - +50°C
DATA SUBJECT TO CHANGE WITHOUT NOTICE
T07 079 1A 3.12.2001
15.2
CHARACTERISTICS OF ELECTRONIC BALLASTS FOR COMPACT LAMPS
Technical values
Max. temperature at tc point
EL-HF2F
EL-CHF
75°C
70 / 75°C
EL-HFC2F
EL-CHFC
75 / 80°C
1)
70 / 75°C
2)
Ambient temperature range
0…+50°C
-15…+50°C
Storage temperature range
-40…+80°C
-30…+80°C
-40…+80°C
-30…+80°C
Maximum relative humidity
no condensation
no condensation
no condensation
no condensation
Number of starts per lamp
> 20 000
> 20 000
> 20 000
> 20 000
+15…+50°C
+5…+50°C
Mains voltage tolerance
±10 %
±10 %
±10 %
±10 %
DC range
180 - 300 VDC
176-276 VDC
180-300 VDC
180-275 VDC
Over voltage
320 VAC, 1h
380 V / 3 min
300 VAC
380 V / 3 min
Power factor (at maximum)
0.98
0.95
0.98
0.97
Earth leakage current
< 0.5 mA
< 0.4 mA
< 0.4 mA
< 0.4 mA
Maximum working voltage (r.m.s.) U-out
Lifetime
90 000 h,
at 50°C Tc
50 000 h,
at Tc max
250 V
90 000 h,
at 50°C Tc
50 000 h,
at Tc max
Max length of ballast to lamp wiring
1m
1m
0.5 m
1m
EL-HF2F
EL-CHF
EL-HFC2F
EL-CHFC
X
Standards
CE marked
X
X
X
General and safety requirements
EN 60928
X
X
X
X
Performance requirements
EN 60929 X
X
-
X
Lamp life acc. to
EN 60081 X
X
X
X
Warm start, acc. to
EN 60929 X
Mains current harmonics, acc. to
Radio Frequency Interference
Immunity standard, acc. to
X
-
X
X
X
X
X
EN 55015 X
X
X
X
X
X
X
EN 61000-3-2
EN 61547 -
2)
Vibration test
EN 60068-2-64 test Fh X
-
X
-
Bump test
EN 60068-2-29 test Eb X
-
X
-
Can be used on DC, acc. to
Thermal protection acc. to
VDE 0108
X
X
X
X
EN 60928 B.5e
X
X
X
X
1) EL 1x18-42 CHF = -20 - +60°C, EL 2x18-40 CHF = -20…+50°C
2) For 36 W 0…50°C
DATA SUBJECT TO CHANGE WITHOUT NOTICE
T07 080 1A 3.12.2001
15.3
16
MAGNETIC BALLASTS & IGNITORS - Instructions for use
All Helvar ballasts are designed to be installed into the same fitting as the lamps they are operating.
Always ensure that all ballast specifications are not exceeded under actual usage conditions.
Wiring considerations
1. Fluorescent lamp ballasts
Wire type
• Solid core conductor only
Mineral insulated cable
• Not advised
Wiring insulation
• According to recommendations in EN 60598
Wire release from ballast
• Use a 1mm² solid pin (or similar) - push in terminals.
Wire cross section dimensions
• 0.5 - 1.0mm²
Wiring layout
• Keep all wiring as short as possible
• Mains wiring and lamp should always be kept as far as
possible from each-other
• Mains wiring should not be bunched together with lamp
wiring
• Avoid wiring 'loops' (to minimise magnetic coupling effect)
• Avoid long parallel cable runs
Wire preparation
• Strip length 8.0mm ± 1mm
Wire connections
• As shown on the ballast label and the Wiring Diagram
datasheets
2. HID (High Intensity Discharge) lamp ballasts
Wire type
Ballasts with push in terminals:
• Solid core conductor only
Ballasts with screw terminals:
• Solid core or stranded conductor
Wiring insulation
• According to recommendations in EN 60598
Wire cross section dimensions
Ballasts with push in terminals:
• 0.5 - 1.5mm²
Ballasts with screw terminals:
• 1.5 - 3.0 mm²
Mineral insulated cable
• Not advised
Wire release from ballast
Ballasts with push in terminals:
• Use a 1mm² solid pin (or similar)
Ballasts with screw terminals:
• Flat blade screwdriver
Wire connections
• As shown on the ballast label and the Wiring Diagram
datasheets
Wire preparation
Ballasts with push in terminals:
• Strip length 8.0mm ± 1mm
Ballasts with screw terminals:
• Strip length 7.0mm ± 1mm
Wiring layout
• Keep all wiring as short as possible
• Mains wiring and lamp should always be kept as far as
possible from each-other
• Mains wiring should not be bunched together with lamp
wiring
• Avoid wiring 'loops' (to minimise magnetic coupling effect)
• Avoid long parallel cable runs
DATA SUBJECT TO CHANGE WITHOUT NOTICE
O10 134 1A 24.1.2002
16.1
MAGNETIC BALLASTS & IGNITORS - Instructions for use
3. Ignitors for HID lamps
Wire type
• Solid core or stranded conductor
Mineral insulated cable
• Not advised
Wiring insulation
• According to recommendations in EN 60598
Wire preparation
• Strip length 7.0mm ± 1mm
Wire cross section dimensions
• 1.5 - 3.0 mm² or 2.0 - 4.0 mm² (depending upon ignitor
type)
• 2.5 - 5.0 mm² (1000W ignitors)
Wire release from ignitor
• Flat blade screwdriver
Wire connections
• As shown on the ignitor label and datasheet
Wiring layout
• Keep wiring from the ignitor to the lamp as short as
possible
Installation & operational considerations
Reflector position
Situating a reflector or metal plate very close to the lamp
may increase RFI emissions and cause excessive
leakage current of the fitting
Ballast earthing
• Required for safety
Lifetime
• Reliable operation and lifetime is only guaranteed if the
maximum winding temperature of tw 130ºC is not
exceeded under the conditions of normal use
Ballast mounting
• The ballast must be located in such a position as to
ensure that its maximum winding temperature of tw
130ºC is not exceeded under the conditions of normal
use
• Mount the ballast against a flat surface to ensure good
heat dissipation
Starting aid
• For reliable starting (and electrical safety) all metal parts
of the fitting must be at the same electrical potential as
the ballast case
Fitting components
• Ensure the correct electrical ratings for the lamps being
used
Ignitor choice
• Helvar ballasts for Metal Halide or High Pressure
Sodium lamps are only suitable for use with
superimposed pulse type ignitors
• Pulsar type ignitors (where a high starting voltage is
applied to the ballast windings) are not suitable for
Helvar ballasts. If used, the ballast winding insulation
will be subjected to increased load. This will drastically
shorten the ballast lifetime
Protection against lamp rectification
• Metal Halide & High-Pressure Sodium lamps can begin
to rectify as they reach the end of their operational
lifetime. This can cause excessive temperature in a
fitting. As such, it is recommended that thermal
protection be fitted in these luminaires
• A thermal protection device should be fitted inside the
luminaire
• Helvar ballasts for Metal Halide & High-Pressure
Sodium lamps are available with thermal protectors
fitted
• Use of ignitors with a timer facility also provide some
protection against lamp rectification. Use in conjunction
with a thermal protector
Noise avoidance
• Ensure the ballast is securely fixed within the luminaire
• Fix the ballast at a minimum distance of 3mm from the
side of the fitting
• Ensure that the fitting is of rigid construction (especially
at the point where the ballast is fitted)
• In large fittings the ballast should be separated from the
fitting by mounting it on an aluminium plate (approx.
2mm thick)
• Mount as few ballasts as possible in one fitting
• If using multiple ballasts in a fitting, ensure that the
ballasts are mounted as far as possible from each other
Site considerations
Mixed technology on the same electrical circuit
• Magnetic and electronic ballasts should not be connected to the same electrical circuit. The energy spikes
produced by magnetic ballasts may result in damage to the electronic ballasts
Miniature Circuit Breakers
• 'Type C' MCB's having trip characteristics in accordance with EN 60898 are recommended.
• 'Type B' MCB's are not recommended due to their sensitivity. If used, they must only be loaded to 60% of the
equivalent 'Type C' MCB
DATA SUBJECT TO CHANGE WITHOUT NOTICE
O10 134 1A 24.1.2002
16.2
ELECTRONIC BALLASTS - Instructions for use
All Helvar ballasts are designed to be installed into the same fitting as the lamps they are operating.
Always ensure that all ballast specifications are not exceeded under actual usage conditions.
Wiring considerations
Wire type
• Solid core conductor only
Wire preparation
• Strip length 7.5mm ± 1mm
Wire cross section dimensions
• 0.5 - 1.5mm²
Wiring capacitance
• 80pF / meter (typical)
Wiring insulation
• According to recommendations in EN 60598
Wire insertion force
• 8 Newtons (typical)
Maximum wire lengths
• See Characteristics datasheets
Wire release from ballast
• Terminals have quick release push buttons
• Some ballasts require the use of a 1mm² solid pin (or
similar).
Wire connections
• As shown on the ballast label and the Wiring Diagram
datasheets
Wiring layout
• Keep all wiring as short as possible (particularly the 'Hot'
wires - see Wiring Diagrams datasheets)
• 'Hot' wires should be of equal length
• ‘Cold' wires should be of equal length
• Mains wiring, lamp wiring and low voltage control wiring
should always be kept as far as possible from eachother
• Mains wiring should not be bunched together with lamp
wiring
• Mains wiring should not be bunched together with lamp
wiring
• Control (ELV) wiring should not be bunched together
with mains or lamp wiring (to minimise cross-talk)
• Avoid wiring 'loops' (to minimise magnetic coupling
effect)
• Avoid long parallel cable runs
Installation & operational considerations
Ballast earthing
• EL-s range is suitable for Class II fittings (no earth
required)
• All other Helvar electronic ballasts require a protective
earth to be connected to ensure reliable operation
Maximum tc temperature
• Reliable operation and lifetime is only guaranteed if the
maximum tc point temperature is not exceeded under
the conditions of use
Master / Slave connection
• Not advised
Frequent switching
• Helvar warm start ballasts may be used in conjunction
with occupancy sensors as long as the 'on' period is
greater than 20 minutes. Shorter switching period may
reduce lamp life
Switching off one lamp via lamp wires
• Not permitted
Starting aid
• For reliable starting (and electrical safety) all metal parts
of the fitting must be at the same electrical potential as
the ballast case
Reflector position
• Situating a reflector or metal plate very close to the lamp
may increase RFI emissions and cause excessive
leakage current of the fitting
Fitting components
• Ensure the correct electrical ratings for the lamps being
used (e.g. 500V rated lampholders are required for T5
lamps)
Ballast mounting position
• Ensure that the entire length of the ballast is against a
flat surface to ensure good heat dissipation
DATA SUBJECT TO CHANGE WITHOUT NOTICE
O07 082 1A 13.12.2001
16.3
ELECTRONIC BALLASTS - Instructions for use
Stand-by function
The stand-by function in Helvar ballasts is designed specifically as a protection for the ballast. It is designed
specifically to switch the lamps off when a lamp ‘end of lifetime’ condition occurs. Lamps can also fail in many other
ways. As such, the exact operating state of the ballast under other lamp fault conditions depends on the specific
failure. The ballast will not be harmed under any normal lamp failure condition.
Lamp 'end of lifetime'
If the electrical characteristics (e.g. lamp voltage) required by the lamps exceeds the internal preset value in the
ballast, the ballast will recognise that one or more lamps has reached the end of its useful operational life. In such
cases the ballast will switch off the supply to the lamps (stand-by) to prevent excessive voltage and / or current being
supplied to the circuit.
Emergency inverter units
• Due to our continuing program of product development and improvement, Helvar's electronic ballast designs are
evolving constantly. This natural evolution may affect compatibility between our electronic ballasts and emergency
conversion modules. It is therefore the responsibility of either the fitting manufacturer, emergency unit supplier and/or
system integrator to ensure the used combination is fully compatible.
Emergency inverter unit recommendations
• Use a 4 pole changeover device, with all 4 poles being
used to disconnect the lamp
• Disconnect the mains supply from the ballast before
the emergency lamp is disconnected, and prior to its
connection to the emergency unit
• Reconnect the emergency lamp to the ballast before
application of the mains supply. A time delay circuit
can be used for this purpose
• For multiple lamp ballasts, the wiring lengths for
emergency and non-emergency lamps should be
equal
• Site considerations
Insulation resistance testing on an installation
• Carry out insulation resistance testing with the fittings disconnected from the mains supply whenever possible (the
complete fitting has already been tested by the manufacturer)
• If fittings are connected to the mains supply during an insulation resistance test, all Live phases and Neutral must be
connected together before the test is carried out.
• Ensure correct re-connection before the mains supply is re-applied.
Mixed technology on the same electrical circuit
• Magnetic and electronic ballasts should not be connected to the same electrical circuit. The energy spikes produced by
magnetic ballasts may result in damage to the electronic ballasts.
Infra-red (IR) system
• Fluorescent lamps operated by electronic ballasts emit, not only visible light, but also infra-red light. In some instances
this may cause interference to IR systems. To minimise the risk of problems the IR system should have a reduced
receiving area. To guarantee successful functionality Helvar recommend that the manufacturer of the IR system be
contacted prior to installation. Helvar ballasts typically operate at frequencies rarely used in IR applications.
3-phase supplies
• Do not apply power to the ballast / fitting without ensuring the Neutral conductor is correctly connected
• Do not disconnect the Neutral conductor unless the supply is off
Miniature Circuit Breakers
• 'Type C' MCB's having trip characteristics in accordance with EN 60898 are recommended.
• 'Type B' MCB's are not recommended due to their sensitivity. If used, they must only be loaded to 60% of the
equivalent 'Type C' MCB
DATA SUBJECT TO CHANGE WITHOUT NOTICE
O07 082 1A 13.12.2001
16.4
17
HELVAR ballasts for fluorescent lamps
Lamp type
ILCOS
W
Cap
T5 - Lamp
FD-H
4
G5
6
G5
8
G5
13
G5
Electronic ballast
L8D
L 8 DL 2)
L8D
L 8 DL 2)
L8D
L 11 D
L 13 TL2-100mm
L 13 DL 2)
ø16mm
14
T8 - Lamp
FD-E
G5
21
G5
24
G5
28
G5
35
G5
39
G5
49
G5
54
G5
80
G5
ø26mm
18
32
36
G13
G13
G13
58
G13
70
G13
EL 1x14-35s
EL 1x14HFT5
EL 3/4x14s
EL 3x14HFT5
EL 1x14-35s
EL 1x21HFT5
EL 1x24s
EL 1x24HFT5
EL 1x14-35s
EL 1x28HFT5
EL 2x14-35s
EL 2x14HFT5
EL 1x28HFCT5
EL 1x28HFIT5
EL 1x14-35s
EL 1x35HFT5
EL 1x35HFCT5
EL 1x35HFIT5
EL 1x39s
EL 1x39HFT5
EL 1x49s
EL 1x49HFT5
EL 1x54s
EL 1x54HFT5
EL 1x80s
EL 1x18HF
EL 3x18HF 1)
EL 1x18HFC
EL 4x14HFT5
EL 2x14-35s
EL 2x21HFT5
EL 2x24s
EL 2x24HFT5
EL 2x14-35s
EL 2x28HFT5
EL 2x28HFCT5
EL 2x28HFIT5
EL 2x14-35s
EL 2x35HFT5
EL 2x35HFCT5
EL 2x35HFIT5
EL 2x39s
EL 2x39HFT5
EL 2x49s
EL 2x49HFT5
EL 2x54s
EL 2x54HFT5
EL 2x18HF
EL 4x18HF 1)
EL 2x18HFC
L 18 A-L
L 18 TL2
L 18 TL3
L 18 TLB2
L 18 A-S
L 20 A
L 18 TL4
L 20 A-P
L 26 TS5 - 100mm
L 26 TS5 - 105mm
EL 2x32HF
EL 1x36HF
EL 1x36HFC
EL 2x36HF
EL 2x36HFC
EL 1x58HF
EL 1x58HFC
EL 2x58HF
EL 2x58HFC
EL 1x70HF
EL 1x70HFC
EL 2x70HF
Types printed BOLD are ENEC approved combinations.
1) Approved to EN60928
2) Approved to EN60921
3) 240V 50Hz
Other combinations mentioned are tested and recommended by Helvar
DATA SUBJECT TO CHANGE WITHOUT NOTICE
O13 095 1A 17.12.2001
Magnetic Ballast (230V 50Hz)
17.1
L 36 TL2
L 36 TL3
L 36 TL4
L 36 TLB2
L 36 A-S
L 58 TL2
L 58 TL3
L 40 A-L
L 40 A-M
L 40 A-P
L 40 A-S
L 36 A-K
L 58 A-S
L 65 A
L 58 TL4
L 65 A-M
L 58 TL4 - 220mm
L 58 TLB2 - 220mm
L 58 TLB2 - 180mm
L 65 A-P
L 65 A-S
L 58 A-K
L 75 A 3)
L 75 A-S 3)
L 70 TL4 2)3)
HELVAR ballasts for fluorescent lamps
Lamp type
ILCOS
T12 - Lamp ø38mm FD-E
W
20
G13
25
G13
40
65
T8-LAMP ø 26 mm
FD-E
l=450 mm
l=720 mm
l=970 mm
l=900 mm
30
T5 circular
Circline
15
16
23
l=970 mm
l=1047 mm
FD-E
Cap
L 15 A
L 15 TL3
L 40 A-L
L 40 A-M
L 40 A-P
L 40 A-S
EL 1x58HF
L 58 A-S
L 58 TL4 - 220mm
L 58 TLB2 - 220mm
L 58 TLB2 - 180mm
L 58 TL2
L 58 TL3
L 58 TL4
L 58 A-K
EL 1x18HF
L 15 A
L 15 A-P
L 16 D
L 15 A-P
L 30 A
L 30 A-P
L 42 A
L 36 TL2
L 36 TL4
L 36 TLB2
L 36 A-S
L 36 A-K
L 36 TL3
L 42 A
G13
G13
G13
G13
G13
36
38
G13
G13
42
22
40
22
32
40
G13
2GX13
2GX13
G10q
G10q
G10q
EL 1x36HF
EL 1x36HFC
EL 1x36HF 1)
EL 1x36HF
EL 1x36HFC
EL 2x36HF
EL 2x36HFC
EL 2x36HF
EL 2x36HF
EL 2x36HFC
EL 1x18-42CHF
EL 1x18-42CHF
EL 2x18-40CHF
EL 2x18-40CHF 3)
40
G13
80
85
100
G13
G13
G13
L 30 TL2
L 32 A
L 36 TL2
L 36 TL3
L 36 TL4
L 36 TLB2
L 36 A-K
L 36 TL2
L 36 TL3
L 36 TL4
L 36 TLB2
L 36 A-S
L 80 A-S
L 85 T6
L 100 T7
140
160
G13
G13
L 140 T9
L 160 EN
EL 1x36HF
FU-E
Types printed BOLD are ENEC approved combinations.
1) Approved to EN60928
2) Approved to EN60921
3) For a combination of one 22W and one 40W T5 circular lamp
Other combinations mentioned are tested and recommended by Helvar
DATA SUBJECT TO CHANGE WITHOUT NOTICE
O13 095 1A 17.12.2001
Magnetic Ballast (230V 50Hz)
L 18 A-L
L 20 A
L 20 A-P
G13
Mod-U-line
UV suntanning
lamps
Electronic ballast
17.2
L 18 TL2
L 18 TL3
L 18 TL4
L 18 TLB2
L 15 A-P
L 36 TL2
L 36 TL3
L 36 TL4
L 36 TLB2
L 36 A-S
L 65 A
L 65 A-M
L 65 A-P
L 65 A-S
L 15 TL3
L 16 DL
L 30 TL2
L40 A-L
L40 A-M
L40 A-P
L40 A-S
L 30 A
L40 A-L
L40 A-M
L40 A-P
L40 A-S
L40 A-L
L40 A-M
L40 A-P
L40 A-S
L 36 A-K
L 100 T9
L 100 T9-100mm 2)
HELVAR ballasts for compact fluorescent lamps
Lamp type
TC-S 2 finger
ILCOS
with starter
FSD-I
TC-E 2 finger
without starter
FSD-E
TC-D 4 finger
W
Cap
5
7
9
11
5
7
9
11
G23
G23
G23
G23
2G7
2G7
2G7
2G7
10
G24d-1
13
G24d-1
18
G24d-2
Electronic ballast
EL 1x9-13CHF
EL 1x9-13CHF
TC-DE 4 finger
without starter
FSQ-E
TC-T 6 finger
26
G24d-3
10
G24q-1
13
G24q-1
18
G24q-2
26
G24q-3
18
GX24d-2
EL 1x9-13CHF
EL 1x10/13CHFC
EL 1x9-13CHF
EL 1x10/13CHFC
EL 1x18CHF
EL 1x18CHFC
EL 1x18-42CHF
EL 1x26CHFC
TC-TE 6 finger
without starter
FSM-E
TC-DD
2D-lamp
GR8, for magnetic
ballast only
GR10q, for
electronic ballast
or magnetic with
external starter
FSS-E
26
GX24d-3
13
GX24q-1
18
GX24q-2
26
GX24q-3
32
GX24q-3
42
GX24q-4
10
GR8, GR10q
16
21
GR8, GR10q
GR8, GR10q EL 1x18HF
28
GR8, GR10q
EL 1x9-13CHF
EL 1x10/13CHFC
EL 1x18CHF
EL 1x18CHFC
EL 1x18-42CHF
EL 1x26CHFC
EL 1x18-42CHF
EL 1x32CHFC
EL 1x18-42CHF
EL 1x42CHFC
EL 1x36HF
38
GR8, GR10q
55
GR8, GR10q EL 1x55HF2F
Types printed BOLD are ENEC approved combinations.
1) Approved to EN60921
Other combinations mentioned are tested and recommended by Helvar
DATA SUBJECT TO CHANGE WITHOUT NOTICE
O13 095 1A 17.12.2001
17.3
L11 DL 1)
L11 DL 1)
L11 DL 1)
L11 DL 1)
L13 D
L13 TL2-100mm
L13 D
L13 TL2-100mm
L18 D
L18 TLD-100mm
L20 A
L18 TL2
L18 TL3
L26 TS5-105mm
L26 TS5-100mm
L13 DL 1)
L13 DL 1)
L18 DL
L20 A-P
L18 A-L
L18 A-S
L18 TL4
L18 TLB2
EL 2x10/13 CHF
EL 2x10/13CHFC
EL 2x10/13 CHF
EL 2x10/13CHFC
EL 2x18CHF
EL 2x18CHFC
EL 2x18-40CHF
EL 2x26CHFC
with starter
FSM-I
L11 D
L11 D
L11 D
L11 D
EL 2x10/13 CHF
EL 2x10/13 CHF
with starter
FSQ-I
Magnetic Ballast (230V 50Hz)
L18 D
L18 TLD-100mm
L20 A
L18 TL2
L18 TL3
L26 TS5-105mm
L26 TS5-100mm
L18 DL
L13 D
L13 TL2-100mm
L16 D
L21 TL2-100mm 1)
L20 A
L18 TL2
L18 TL3
L18 TLB2
L36 TL2
L36 TL3
L36 TL4
L36 TL2B2
L13 DL
L20 A-P
L18 A-L
L18 A-S
L18 TL4
L18 TLB2
EL 2x10/13 CHF
EL 2x10/13CHFC
EL 2x18CHF
EL 2x18CHFC
EL 2x18-40CHF
EL 2x26CHFC
EL 2x18-40CHF
EL 2x32CHFC
EL 2x42CHF
L16 DL
L20 A-P
L18 A-S
L18 A-L
L18 TL4
L40 A-P
L40 A-M
L40 A-S
L36 A-S
L36 A-K
HELVAR ballasts for compact fluorescent lamps
Lamp type
TC-L 2 finger
ILCOS
Cap
Ø
17.5
18
FSD-E
TC-F
W
24
2G11
34
2G11
36
2G11
40
2G11
55
2G11
18
2G10
24
EL 1x18-42CHF
EL 1x18CHFC-L/F
EL 2x18-40CHF
EL 2x18CHFC-L/F
EL 1x18-42CHF
EL 1x24CHFC-L/F
EL 2x18-40CHF
EL 2x24CHFC-L/F
EL 1x36HF
EL 2x36HF2F
EL 1x18-42CHF
EL 2x36HF2F
EL 1x36HF
EL 1x36HFC2F 1)
EL 2x36HFC2F 1)
EL 1x18-42CHF
EL 2x36HF2F
EL 1x55HF2F
EL 2x55HF2F
EL 1x36HF 1)
EL 1x40HFC2F 1)
EL 1x55HFC2F 1)
2G11
Flat 4 finger
FSS-E
Electronic ballast
EL 1x18HF
EL 1x18-42CHF
EL 1x18CHFC-L/F
EL 2x18-40CHF
EL 2x18CHFC-L/F
EL 1x18-42CHF
EL 1x24CHFC-L/F
EL2x18-40CHF
EL 2x24CHFC-L/F
2G10
EL 1x18-42CHF
EL 1x36HF
36
2G10
Types printed BOLD are ENEC approved combinations.
1) Approved to EN60928
Other combinations mentioned are tested and recommended by Helvar
DATA SUBJECT TO CHANGE WITHOUT NOTICE
O13 095 1A 17.12.2001
17.4
EL 2x36HF
EL 2x36HF2F
Magnetic Ballast (230V 50Hz)
L26 TS5-100mm
L26 TS5-105mm
L20 A
L18 TL2
L18 TL3
L26 TS5-100mm
L26 TS5-105mm
L20 A
L18 TL2
L18 TL3
L18 TL4
L18 TLB2
L20 A-P
L18 A-S
L18 A-L
L18 TL4
L18 TLB2
L20 A-P
L18 A-S
L18 A-L
L36 TL2
L36 TL3
L36 TL4
L36 A-K
L36 TLB2
L40 A-P
L40 A-M
L40 A-S
L36 A-S
L20 A
L18 TL2
L18 TL3
L18 TL4
L20 A
L18 TL2
L18 TL3
L18 TL4
L26 TS5-100mm
L26 TS5-105mm
L40 A-P
L40 A-M
L36 TL2
L36 TL3
L36 TL4
L20 A-P
L18 A-S
L18 A-L
L18 TLB2
L20 A-P
L18 A-S
L18 A-L
L18 TLB2
L40 A-S
L36 A-S
L36 TLB2
L36 A-K
Markings of lamp types
Name
Symbol
Marking
Cap
Sylvania
Osram
Philips
Thorn
Tungsram
GE
T26 (T8)
G13
F
L
TL
F
F
T16 (T5)
G5
F
L
TL
F
F
TC-S
G23
LYNX-S
Dulux S
PL-S
-
FD
Biax™ S
TC-SE
2G7
LYNX-SE
Dulux SE PL-S
-
FD/E
Biax™ SE
TC - D
G 24 d
LYNX-D
Dulux D
PL-C
-
FD-D
Biax™ D
TC-DE
G 24 q
LYNX-DE
Dulux D/E PL-C
-
FD-D/E
Biax™ D/E
TC-T
GX 24 d
LYNX-T
Dulux T
PL-T
-
-
Biax™ T
TC-TE
GX 24 q
LYNX-TE
Dulux T/E PL-T
-
-
Biax™ T/E, QE
TC-L
2 G 11
LYNX-L,-LE Dulux L
PL-L
2L
FD-L
Biax™ L
TC-DD
GR8,GR10q -
-
-
2D
-
Biax™ 2D™
Fluorescent lamps
Compact fluorescent lamps
T-R,28/30,T9 G 10 q
FC
FC
TL-E
-
-
Circline®
T-R,16,T5
2GX13
FC
FC
TL 5 C
-
-
-
TC-F
2 G 10
LYNX-F
Dulux F
-
-
-
-
HME
E27, E 40
HSL
HQL
HPL
MBF
HqLI
HqLI
HMG
E27
-
HQL-B
HPL-B
-
-
-
HMR
E27, E40
HSR-BW
HQL-R
HPL-R
MBFR
-
MBFR
HST
E 27, E40
SHP-T
NAV-T
SON-T
SON-T
TCF
SON-T
HSE
E 27, E40
SHP-E
NAV-E
SON
SON-E
TCL
SON-E
HSE-I
E 27, E40
SHP/I
NAV-E
SON
-
-
Lucalox I
HST-DE
R 7 S, Fc 2
-
NAV-TS
-
SON-TD -
SON-TD
HSE-X
E27, E 40
SHX
NAV-E
SON-H
-
-
SONClassique
HIT
G 12
HIS-T
HQI-T
MHN-T
(PG12)
MBI-T/
BOH
-
MBI-T
HIT
E 40
HIS-T
HQI-T
HPI-TD
MQI-T
HqMIF
MBIF
HIT-DE
R 7 S, Fc 2
HIS-TD
HQI-TS
MHN-TD
MBIL
HPI-TD
HqMIS
MQI
HIT-I
E40
-
HQI-T
HPI-BUS -
-
MBI-T
HIE
E27, E 40
M (E27)
HQI-E
HPI
MBI
HqMIL
MBI
HIR
E40
-
HQI-R
-
-
HqMIR
-
High pressure mercury lamps
High pressure sodium lamps
Substitutive high pressure sodium lamps
Metal halide lamps
DATA SUBJECT TO CHANGE WITHOUT NOTICE
O13 094 1A 14.2.2002
17.5
18
Packing details for MAGNETIC and ELECTRONIC BALLASTS
Magnetic ballasts & ignitors
UNIT PACKAGE
BALLAST TYPE
TRANSPORTATION PACKAGE
PCS PLASTIC CARTON
BINDING BOX
STRIP
ALF
18 - 36TL
TS,TLD,21TL
13 TL
58 - 100W
10
10
10
10
10
X
X
X
X
X
LA 40W
10
X
LA 65W
L11D
SHID
BHID
E250 - 400T, H400T
NK150 - 250T
E250 - 400F, H400F
NK150 - 250F
NK400T/F
10
30
4
X
EURO-HID
3
IGNITORS
50
X
EURPALLET
PALLET
HEIGHT
KG
CM
1800
960
720-1190
1010-1159
605
1080
A 602-1256
AP 545-1135
720-1215
612
527-1170
53
63
38
45
68
68
58
40
50
800X1200 770X1080 730X650 730X1120
PCS
PCS
PCS
PCS
1250
2100
1200
750
2000
1000
1200
1800
X
1400
1500
750
840
-
2000
960
1200
720
432
5
X
300
530-750
48
4
X
240
530-1060
48
860-910
50
X
360-450630
DATA SUBJECT TO CHANGE WITHOUT NOTICE
18.1.2002
PALLET
WEIGHT
ONE WAY PALLET
DIMENSIONS OF PALLETS
18.1
Packing details for MAGNETIC and ELECTRONIC BALLASTS
Electronic ballasts
UNIT PACKAGE
BALLAST TYPE
EL1 x HF,
EL1 x HFT5
EL1 x HFC,
EL2 x HF,
EL2 x HFT5
EL1 x HFCT5
EL1 x HFTI5
EL3 x HF,
EL4 x HF,
EL2 x HFC
EL2 x HFCT5
EL2 x HFIT5
EL1 x s
EL2 x s
EL3/4 x s
EL1 x CHFC-L/F
EL2 x 18CHFC-L/F
EL2 x CHFC
EL1 x CHFC
EL2 x CHF
EL2 x 18CHFC
EL2 x 24CHFC-L/F
EL2 x 10/13CHF
EL1 x 10-13CHFC
EL1 x 9-13CHF
EL1 x 18CHF
EL1 x 18-42CHF
PCS
TRANSPORTATION PACKAGE
PLASTIC CARTON
BINDING
BOX
STRIP
PALLET PALLET
ONE WAY PALLET
EURWEIGHT HEIGHT
DIMENSIONS OF PALLETS
PALLET
800X1200 770X1080 730X650 730X1120
PCS
PCS
PCS
PCS
KG
CM
10
X
1000
300
43
10
X
1000
370
60
10
X
840
360
54
10
X
1000
250
40
10
X
1000
320
40
20
X
25
X
35
X
DATA SUBJECT TO CHANGE WITHOUT NOTICE
18.1.2002
18.2
19
DIGIDIM products
For further information on Helvar‘s lighting control product range, please see the Helvar Lighting
Control web site at www.helvar.co.uk
MULTI-SENSOR (312)
The Multi-sensor module contains the required sensors to provide the
energy saving benefits of an automated lighting control system; a
constant light sensor, passive infra-red presence detector and
infra-red remote control receiver.
Constant Light
Range of 5-5000 Lux
Viewing angle 40 or 100
Omni-directional
PIR Detector
IR REMOTE CONTROL (303)
The remote control is designed to operate basic
system functions and to provide simple programming facilities. The
remote has the following functions:
On/off button.
Raise (modifier button).
Lower (modifier button).
Four scene recall/configuration buttons.
1-10V CONVERTER (470)
1-10V DALI Converter suitable for controlling Helvar controllable
ballasts thus enabling a DIGIDIM system to operate and to integrate
into, existing analogue systems.
Supply Voltage
Supply Frequency
Output Relay Rating
Product Dimensions
197-264VAC (absolute)
48-62Hz (absolute)
Single pole 10A resistive load
(maximum 15 HFC ballasts)
90mm x 71mm x 58mm
POWER SUPPLY (400)
Supplies power to DALI control systems.
Supply Voltage
Supply Frequency
DALI Power Supplied
Product Dimensions
197-264VAC (absolute)
48-62Hz (absolute)
240mA (maximum)
90mm x 71mm x 58mm
Note: This unit is not always required in systems that contain one or
more of the following products; 416, 425, 450, 460 and DIGIDIM
ballasts.
DATA SUBJECT TO CHANGE WITHOUT NOTICE
T13 098 1A 29.1.2002
19.1
Download