Indicator Lights Neon, LED and Filament Lamp

advertisement
22-Cat171_P066-073|Indicator Lights:Cat No.171_Oct 2011
Indicator Lights
16/11/11
AC
Page 68
Neon, LED and Filament Lamp
Colours and voltages:
DC
10:41
Neon
Available with Red, Amber, Green or Clear lenses
100/130V (marked 110V), 200/250V (marked 230V)
LED - DC
Red, Yellow, Green, Blue, White
2.0/2.2V Resistors for other voltages available.
LED - AC
Red, Yellow, Green, Blue, White
110-230V ac operation.
Filament lamp Available with Red, Amber, Green, Clear or Blue lenses
6V, 12/14V, 24/28V.
៉ Neon, LED, mains LED or
filament lamp
៉ Bezel sizes from 6.7 to 16.3mm
diameter
៉ Red, amber, green, blue and
clear lenses
៉ Red, yellow, green, blue and
white LEDs
៉ Wide choice of styles
To create a catalogue number:
Refer to the 2 columns below (terminal and type), then state: Lens colour,
voltage and whether neon, LED or filament lamp
TERM
L
TYPE
PANEL & ˚C
ILLUM’N
APPROVAL
OPTIONS
DIMENSIONS (mm)
3
(L) 0569 AW
9.0
19.0
3.0
DC
0.8-2.5
Call
sales
L
(C) 0273 OO
2.0 max
H 4.8
(C) 0278 OO
12.0
Ø10.0
22.2
32.8
3.1
Ø12.2
33.5
9.0
2.0 max
H 4.8
DC
22.3
23.5
3.5
12.0 Sq.
AC
page 6
C 6.3
(C) 0276 AA
23.5
9.5
K 2.8
0.8-2.8
H 4.8
indicators
8.5
max
AC
K 2.8
DC
22.2
33.0
4.0
Ø12.0
AC
33.7
page 6
C 6.3
L
DC
page 6
C 6.3
L
23.0
9.0
K 2.8
L
AC
16.0
(C) 0275 OO
10.0
K 2.8
12.0 max
H 4.8
22.2
32.5
3.0
Ø13.3
AC
page 6
C 6.3
L
DC
(C) 0275 OO
32.7
16.0
Chrome bezel
10.0
Ø13.3
K 2.8
11.5 max
22.2
H 4.8
C 6.3
DC
32.0
32.5
AC
page 6
32.7
68
tel: +44 (0)20 8979 3232 • Arcolectric • email: europe@elektron-technology.com
3.5
3.0
Ø15.6
22-Cat171_P066-073|Indicator Lights:Cat No.171_Oct 2011
TERM
L
TYPE
16/11/11
PANEL & ˚C
(C) 0276 OO
2.8 max
H 4.8
ILLUM’N
APPROVAL
OPTIONS
DIMENSIONS (mm)
DC
22.2
4.0
33.0
Ø12.0
AC
page 6
C 6.3
K 2.8
Page 69
10.0
K 2.8
L
10:41
(C) 0277 OO
Chrome bezel
(C) 0277 OO
Chrome bezel
33.7
14.9
10.0
12.0 max
DC
3.3
22.2
8.3
53.7
H 4.8
Ø14.6
AC
page 6
C 6.3
32.2
L
(C) 0273 LL
K 2.8
0.6-2.0
H 4.8
16.6
Ø8.8
12.0
H 4.8
DC
AC
10.0
22.8
10.0
22.8 1.6
5.0
Ø13.6
page 6
(C) 2821 OO
K 2.8
12.0 or 12.7
ø12.0
= 0.8-2.5
ø12.7
= 1.1-2.5
H 4.8
indicators
C 6.3
DC
AC
page 6
C 6.3
(C) 0586 OO
Ø14.5
12.5
K 2.8
0.8-1.5
H 4.8
C 6.3
18.4
35.7
(C) 2820 OO
0.75-2.0
L
22.2
page 6
K 2.8
L
DC
AC
C 6.3
L
For sub-panel mounting, behind a facia.
10.0
DC
AC
page 6
10.0
25.1
1.8
15.5 Sq
69
tel: +44 (0)20 8979 3232 • Arcolectric • email: europe@elektron-technology.com
04-Cat171_P004-006|Tech Info:Cat No.171_Oct 2011
16/11/11
09:39
Page 6
Technical Information - Indicators
The majority of Arcolectric indicator lights can be supplied with alternative light sources:
technical
data
Neon, Fluorescent, Filament lamp or LED.
NEON and FLUORESCENT LAMPS
FILAMENT LAMPS
Colours
Colours
Available with Red, Amber, Green, Blue or Clear lenses.
Available with Red, Amber, Green, Clear or Blue lenses.
Maximum striking voltages
LEDs - DC
Standard brightness types 65Vac 90Vdc.
Colours
High brightness types 85Vac 135Vdc.
Red, Yellow, Green, Blue and White.
High brightness types are usually fitted.
Voltage
Life
Basic voltage 2.0/2.2V. Some items are available with integral resistors for
Typically 25,000 hours (Green fluorescent lamps 20,000 hours). (Measured to
12V use. For details of resistors required for higher voltages, please call
a point when the light output of the lamp is half its original level.)
sales.
The end of life for a neon lamp is not usually a sudden failure.
Current
False signals due to long wiring
Maximum continuous forward current 20mA.
It is possible for neon or fluorescent tubes to glow when they should be off. The
false signal is caused by the capacitance effect of fairly long wiring to the
Life
indicator being adjacent to other live cables. This effect can be prevented in
>100,000hrs
most cases by fitting a 100k resistor across the supply wires close to the
indicator assembly.
LEDs - AC
Colours
MATERIALS
Red, Yellow, Green, Blue and White.
Moulded bodies and bases . . . . . . . . . . .Nylon 6.6
Metal bodies and bezels . . . . . . . . . . . .Chrome plated brass (except #)
Voltage
Lenses . . . . . . . . . . . . . . . . . . . . . . . . .Polycarbonate
Rated up to 230V ac, suitable for use at 110V and 230V ac.
Terminals (most types) . . . . . . . . . . . . . .Brass (electro-tin plated)
Terminals (exceptions) . . . . . . . . . . . . . .Brass (flash silver* or nickel** plated)
Current
Threaded metal nuts . . . . . . . . . . . . . . .Brass (nickel plated on 0275/7)
<3mA
Other fixings . . . . . . . . . . . . . . . . . . . . .Call sales for details
* R9, 0061, 0062, 0430, 0480, 1090, 1091, 6030, 7030, 8630, 8580
** # 3130, 3160, 3161, 3221 have nickel plated terminals with steel screws
Life
>100,000hrs
and plated polyamide bezel trims
TEMPERATURE RATING
Authority
with Terminals
with Wire leads
PVC
European
T125°C
UL
T65/75°C
SILICONE
T125°C
T105°C
T65/75°C
SYMBOLS
6
Terminals
Wire leads
Solid wires
C 6.3, H 4.8, K 2.8
200mm long Standard
LED only
Panel hole size
Panel thickness
tel: +44 (0)20 8979 3232 • Arcolectric • email: europe@elektron-technology.com
Temperature rating
Download