22-Cat171_P066-073|Indicator Lights:Cat No.171_Oct 2011 Indicator Lights 16/11/11 AC Page 68 Neon, LED and Filament Lamp Colours and voltages: DC 10:41 Neon Available with Red, Amber, Green or Clear lenses 100/130V (marked 110V), 200/250V (marked 230V) LED - DC Red, Yellow, Green, Blue, White 2.0/2.2V Resistors for other voltages available. LED - AC Red, Yellow, Green, Blue, White 110-230V ac operation. Filament lamp Available with Red, Amber, Green, Clear or Blue lenses 6V, 12/14V, 24/28V. ៉ Neon, LED, mains LED or filament lamp ៉ Bezel sizes from 6.7 to 16.3mm diameter ៉ Red, amber, green, blue and clear lenses ៉ Red, yellow, green, blue and white LEDs ៉ Wide choice of styles To create a catalogue number: Refer to the 2 columns below (terminal and type), then state: Lens colour, voltage and whether neon, LED or filament lamp TERM L TYPE PANEL & ˚C ILLUM’N APPROVAL OPTIONS DIMENSIONS (mm) 3 (L) 0569 AW 9.0 19.0 3.0 DC 0.8-2.5 Call sales L (C) 0273 OO 2.0 max H 4.8 (C) 0278 OO 12.0 Ø10.0 22.2 32.8 3.1 Ø12.2 33.5 9.0 2.0 max H 4.8 DC 22.3 23.5 3.5 12.0 Sq. AC page 6 C 6.3 (C) 0276 AA 23.5 9.5 K 2.8 0.8-2.8 H 4.8 indicators 8.5 max AC K 2.8 DC 22.2 33.0 4.0 Ø12.0 AC 33.7 page 6 C 6.3 L DC page 6 C 6.3 L 23.0 9.0 K 2.8 L AC 16.0 (C) 0275 OO 10.0 K 2.8 12.0 max H 4.8 22.2 32.5 3.0 Ø13.3 AC page 6 C 6.3 L DC (C) 0275 OO 32.7 16.0 Chrome bezel 10.0 Ø13.3 K 2.8 11.5 max 22.2 H 4.8 C 6.3 DC 32.0 32.5 AC page 6 32.7 68 tel: +44 (0)20 8979 3232 • Arcolectric • email: europe@elektron-technology.com 3.5 3.0 Ø15.6 22-Cat171_P066-073|Indicator Lights:Cat No.171_Oct 2011 TERM L TYPE 16/11/11 PANEL & ˚C (C) 0276 OO 2.8 max H 4.8 ILLUM’N APPROVAL OPTIONS DIMENSIONS (mm) DC 22.2 4.0 33.0 Ø12.0 AC page 6 C 6.3 K 2.8 Page 69 10.0 K 2.8 L 10:41 (C) 0277 OO Chrome bezel (C) 0277 OO Chrome bezel 33.7 14.9 10.0 12.0 max DC 3.3 22.2 8.3 53.7 H 4.8 Ø14.6 AC page 6 C 6.3 32.2 L (C) 0273 LL K 2.8 0.6-2.0 H 4.8 16.6 Ø8.8 12.0 H 4.8 DC AC 10.0 22.8 10.0 22.8 1.6 5.0 Ø13.6 page 6 (C) 2821 OO K 2.8 12.0 or 12.7 ø12.0 = 0.8-2.5 ø12.7 = 1.1-2.5 H 4.8 indicators C 6.3 DC AC page 6 C 6.3 (C) 0586 OO Ø14.5 12.5 K 2.8 0.8-1.5 H 4.8 C 6.3 18.4 35.7 (C) 2820 OO 0.75-2.0 L 22.2 page 6 K 2.8 L DC AC C 6.3 L For sub-panel mounting, behind a facia. 10.0 DC AC page 6 10.0 25.1 1.8 15.5 Sq 69 tel: +44 (0)20 8979 3232 • Arcolectric • email: europe@elektron-technology.com 04-Cat171_P004-006|Tech Info:Cat No.171_Oct 2011 16/11/11 09:39 Page 6 Technical Information - Indicators The majority of Arcolectric indicator lights can be supplied with alternative light sources: technical data Neon, Fluorescent, Filament lamp or LED. NEON and FLUORESCENT LAMPS FILAMENT LAMPS Colours Colours Available with Red, Amber, Green, Blue or Clear lenses. Available with Red, Amber, Green, Clear or Blue lenses. Maximum striking voltages LEDs - DC Standard brightness types 65Vac 90Vdc. Colours High brightness types 85Vac 135Vdc. Red, Yellow, Green, Blue and White. High brightness types are usually fitted. Voltage Life Basic voltage 2.0/2.2V. Some items are available with integral resistors for Typically 25,000 hours (Green fluorescent lamps 20,000 hours). (Measured to 12V use. For details of resistors required for higher voltages, please call a point when the light output of the lamp is half its original level.) sales. The end of life for a neon lamp is not usually a sudden failure. Current False signals due to long wiring Maximum continuous forward current 20mA. It is possible for neon or fluorescent tubes to glow when they should be off. The false signal is caused by the capacitance effect of fairly long wiring to the Life indicator being adjacent to other live cables. This effect can be prevented in >100,000hrs most cases by fitting a 100k resistor across the supply wires close to the indicator assembly. LEDs - AC Colours MATERIALS Red, Yellow, Green, Blue and White. Moulded bodies and bases . . . . . . . . . . .Nylon 6.6 Metal bodies and bezels . . . . . . . . . . . .Chrome plated brass (except #) Voltage Lenses . . . . . . . . . . . . . . . . . . . . . . . . .Polycarbonate Rated up to 230V ac, suitable for use at 110V and 230V ac. Terminals (most types) . . . . . . . . . . . . . .Brass (electro-tin plated) Terminals (exceptions) . . . . . . . . . . . . . .Brass (flash silver* or nickel** plated) Current Threaded metal nuts . . . . . . . . . . . . . . .Brass (nickel plated on 0275/7) <3mA Other fixings . . . . . . . . . . . . . . . . . . . . .Call sales for details * R9, 0061, 0062, 0430, 0480, 1090, 1091, 6030, 7030, 8630, 8580 ** # 3130, 3160, 3161, 3221 have nickel plated terminals with steel screws Life >100,000hrs and plated polyamide bezel trims TEMPERATURE RATING Authority with Terminals with Wire leads PVC European T125°C UL T65/75°C SILICONE T125°C T105°C T65/75°C SYMBOLS 6 Terminals Wire leads Solid wires C 6.3, H 4.8, K 2.8 200mm long Standard LED only Panel hole size Panel thickness tel: +44 (0)20 8979 3232 • Arcolectric • email: europe@elektron-technology.com Temperature rating