STO CONCRETE BLOCK DRAWING REGISTER

advertisement
Drawing Description
STO DRAWING REGISTER
Drawing No.
Drawing Register
CB 001 - 002
Introduction Series 000
Sto Concrete Block Construction & Detailing
Sto Concrete Block Construction & Detailing
Sto Concrete Block Construction & Detailing
Sto Concrete Block Plaster System
CB 003
CB 004
CB 005
CB 006
Block Layout Series 100
Sto Concrete Block Stoarmat Miral System - Isometric
CB 100
Foundation Series 200
Sto Concrete Block Rebated Slab-on-Ground
Sto Concrete Block Non-Rebated Slab-on-Ground
Sto Concrete Block Strip Footing Detail
Sto Concrete Block Tanking to Plaster Transition
CB 200
CB 201
CB 202
CB 203
Walls Series 300
Sto Concrete Block Vertical Control Joint
Sto Concrete Block Stair Waterproofing Detail
Sto Concrete Block Inter-Storey Slab Detail
CB 300
CB 301
CB 302
Wall Penetrations & Fittings Series 350
Sto Concrete Block Pipe Penetration (up to 150mm Ø) Detail
Sto Concrete Block Meterbox
Sto Concrete Block Fan Vent Detail
Sto Concrete Block Architectural Profile
Sto Concrete Block Handrail
Sto Concrete Block RWH/Scupper Opening
CB 350
CB 351
CB 352
CB 353
CB 354
CB 355
Joinery Series 400
Sto Concrete Block Alu.Joinery - Head & Sill Detail
Sto Concrete Block Alu.Joinery - Jamb Detail
Sto Concrete Block Alu.Entry Door Head & Threshold Detail
Sto Concrete Block Alu.Entry Door Jamb Detail
Sto Concrete Block Timber Joinery - Head & Sill Detail
Sto Concrete Block Timber Joinery - Jamb Detail
Sto Concrete Block Timber Entry Door Head & Threshold Detail
Sto Concrete Block Timber Entry Door Jamb Detail
CB 400
CB 401
CB 402
CB 403
CB 404
CB 405
CB 406
CB 407
Parapets, Balustrades, Decks Series 500
Sto Concrete Block Parapet/Metal Flashing Detail
Sto Concrete Block Plastered Parapet/Balustrade Detail
Sto Concrete Block Uncoated, Painted, Clear Coated or Plastered Parapet Detail
Sto Concrete Block Parapet/Roof/Wall Detail
Sto Concrete Block StoFlexyl Waterproofing Membrane - Isometric
CB 500
CB 501
CB 502
CB 503
CB 504
THESE DETAILS ARE ISSUED AS A GUIDE INCORPORATING STANDARD BUILDING PRACTICES.
ALWAYS REFER TO MANUFACTURERS CURRENT DETAILS AND SPECIFICATIONS.
THE SEQUENCE OF WORK COVERS VARIOUS BUILDING COMPONENTS, EACH TRADE IS
RESPONSIBLE TO ENSURE THEIR ELEMENTS ARE FULLY INCBALLED INCLUDING ALL
WATERPROOFING/SEALANT/ FLASHINGS AS IS APPLICABLE.
PAGE 1 OF 2
STO CONCRETE
BLOCK
STO CONCRETE BLOCK
CB 001
DRAWING REGISTER
2014
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
Drawing Description
STO DRAWING REGISTER
Drawing No.
Soffit Series 600
Sto Concrete Block Eaves with Overhang
Sto Concrete Block Eaves without Overhang
Sto Concrete Block Barge with Overhang
Sto Concrete Block Roof to Conc.Block Gable End
Sto Concrete Block Raking Soffit (Reversed)
CB 600
CB 601
CB 602
CB 603
CB 604
Roof Series 700
Sto Concrete Block Gable End/Roof Junction
Sto Concrete Block Apron Flashing
Sto Concrete Block Parallel Roof/Hidden Gutter
Sto Concrete Block Face Fixed Fascia/Membrane Roof
CB 700
CB 701
CB 702
CB 703
Dissimilar Material
Bevel-Back Weatherboard Series 800
Sto Concrete Block Ext.Corner
Sto Concrete Block Int.Corner
Sto Concrete Block Horizontal Junction
CB 800
CB 801
CB 802
Brick Series 810 series not issued
Fibre Cement Sheet Series 820 series not issued
Manufactured Stone - Schist & Natural Stone Series 840 series not issued
Profile Metal Series 850
Sto Concrete Block Ext.Cnr Horiz.Profiled Metal
Sto Concrete Block Int.Cnr Horiz.Profiled Metal
Sto Concrete Block Horizontal Junction Horiz.Profiled Metal
Sto Concrete Block External Corner Vertical Profiled Metal
Sto Concrete Block Internal Corner Vertical Profiled Metal
Sto Concrete Block Horiz.Junction Vertical Profiled Metal
CB 850
CB 851
CB 852
CB 853
CB 854
CB 855
Stotherm Panel EIPS 860 series not issued
DISSIMILAR JOINERY Series 870 series not issued
THESE DETAILS ARE ISSUED AS A GUIDE INCORPORATING STANDARD BUILDING PRACTICES.
ALWAYS REFER TO MANUFACTURERS CURRENT DETAILS AND SPECIFICATIONS.
THE SEQUENCE OF WORK COVERS VARIOUS BUILDING COMPONENTS, EACH TRADE IS
RESPONSIBLE TO ENSURE THEIR ELEMENTS ARE FULLY INCBALLED INCLUDING ALL
WATERPROOFING/SEALANT/ FLASHINGS AS IS APPLICABLE.
PAGE 2 OF 2
STO CONCRETE
BLOCK
STO CONCRETE BLOCK
CB 002
DRAWING REGISTER
2014
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
SILL BLOCKS SHOULD BE FILLED.
CREATE OPENING TO ENABLE BLOCK
MORTAR TO FLOW THROUGH. REMOVE
PROJECTING SILL FOR A FLUSH FINISH
ENSURE CONC.BLOCK WALLS ARE
SUPPORTED DURING CONSTRUCTION
45mm MIN.REBATE IS RECOMMENDED
MORTAR = 10mm +/- 3mm
ALLOW MORTAR JOINTS TO BE
TOOL COMPRESSED
A NON-REBATED FOUNDATION
REQUIRES 100mm STO FLEXYL
MESHED WATERPROOFING STRIP
CENTERED OVER FLOOR JOINT
NOTE:
1. MAIN CONTRACTOR IS TO ENSURE SEPARATE WALLS, STAIRS or DISSIMILAR
MATERIAL AGAINST BLOCKWORK ARE WATERPROOFED AS NECESSARY TO
FORM A WATERTIGHT CONNECTION WITH THE STO PLASTER SYSTEM
2. IT IS CRITICAL IN PARTIALLY FILLED BLOCKS THAT JOINTS ARE TOOLED FOR
EARTHQUAKE RESISTANCE
3. MASONRY CONCRETE BLOCKS as per NZS4210 / 4229 &4230 or SPECIFIC
ENGINEER DESIGN
4. ALLOW ADEQUATE TIME FOR BLOCKS TO DRY/STABILISE BEFORE PLASTERING.
IN NORMAL DRYING CONDITIONS 4-8 WEEKS
5. CONTROL JOINTS - REFER ENGINEERS SPECIFICATION, BLOCK
MANUFACTURERS RECOMMENDATION or NZS4229
SCALE 1:20
STO CONCRETE
BLOCK
STO CONCRETE BLOCK
CB 003
CONSTRUCTION & DETAILING
2014
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
CONCRETE BLOCK CONSTRUCTION & DETAILING
Responsibility
All work in this section shall be the responsibility of the Main Contractor. All concrete block
construction must be in accordance with the project drawings, specifications and block
manufactures technical data. The Main Contractor is to ensure they are fully conversant with all Sto
standard installation and fixing details (Sto ACAD details www.sto.co.nz) and their responsibilities
before the block works commences. The Main Contractor is also responsible for all liaison with the
various sub contractors to ensure that all items or elements affecting the Sto Plaster System are
correctly detailed before installing the StoArmat Miral Plaster System.
Concrete Blocks
The concrete block installation including reinforcement and concrete infill shall be made in strict
accordance with the project drawings, specifications and the block manufactures technical
documentation. In particular the blocks shall be laid true in both vertical and horizontal planes with all
joinery and service openings correctly formed and waterproofed in accordance with Sto details.
Control joints must be installed as per the projects structural drawings or manufactures details to
manage shrinkage and structural stress. The ground floor slab to block junction should be rebated to
provide waterproofing and inter-storey floors should be poured within the block structure leaving the
outer block shell to continue to avoid cracking. At least 28 days should be allowed after concrete
placement - as per AS/NZS 2311:2000 for curing and stabilization to take place before commencing
the StoArmat Miral Plaster System. All maximum tolerances shall be in strict accordance with
NZS4210:2001 2.7.1.4, Table 2.2 IE: no more than 3mm surface alignment deviation over a 1200mm
radius. The concrete blocks shall be clean, dry and free of all surface contaminants before plastering
and the Main Contractor is to ensure that any area or details adjacent to the Sto Plaster System have
been adequately waterproofed or flashed to avoid any water migration behind the plaster system.
Construction Block Construction
•
•
•
•
•
•
•
•
•
•
•
•
•
A rebate is recommended in foundations for residential projects unless an exterior insulation
system is detailed.
Joinery openings are to be formed using rebated blocks & sill blocks (cut sill flush as required).
Blocks should be covered on site and laid dry.
Vertical control joints are placed at 6.0M max.centres - refer project documentation and NZS4229
for placement and detailing.
Mortar to be 12.5MPa min.tool smooth and compressed as per NZS4210
Manufacturers bagged mortar is recommended to meet the specifications
Mortar to full depth of webbing up to 20MM thick in first course and then 10MM +/- 3mm
Washout ports required to remove mortar droppings from foundation
Ensure there is no impediment to grout flow, remove ends or biscuits to prevent air pockets
Stack bonded, column blocks and insulation block voids may need to be grouted by the block
layer during laying process to ensure a solid fill is achieved
Blocks should be filled in 1.2 lifts and mechanically vibrated to avoid air voids and subsequence
efflorescence
Sill block should be filled by leaving one sill block out to avoid air entrapment
Remove any grout slurry from block faces before it sets
STO CONCRETE
BLOCK
STO CONCRETE BLOCK
CB 004
CONSTRUCTION & DETAILING
2014
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
CONCRETE BLOCK CONSTRUCTION & DETAILING......cont.
Construction Block Construction
•
•
•
•
Drying times vary according to block thickness, grout and weather. A min.28days is
required for settlement & curing - the blocks must be completely dry before coating
Where occupied walls are back filled a 50 year tanking membrane is required.
Always waterproof blocks behind or adjacent to any overlays or abutments such as
concrete staircases, separate adjoining garden walls, soffits, porches, posts etc.
Exposed tops of walls require waterproofing and should be finished with block caps
Exterior Insulation - refer to Sto Concrete Block Insulation Details
NZBC Acceptable Solution H1/AS1 or NZBC Verification Method H1/VM1 can be used for housing,
communal residential, communal non-residential and commercial buildings. For buildings with a
glazing area of 30% or less of the total wall area, the minimum wall R-values required for solid
construction are:
Climate Zone 1 (Nth Coromandel) - R0.8 (option 1a and 1b)
Climate Zone 2 Nth Island, Sth Coromandel excluding the Central Plateau - R1.0 (option 2a) or R0.9
(option 2b)
Climate Zone 3 Sth Island and Central Plateau) - R1.2 (option 3a) or R1.0 (option 3b)
Refer to the BRANZ House Insulation Guide Third Edition for further information and construction
R-values for concrete block construction with External Insulation.
Interior Insulation
Generally involves 90mm framing inside and installing insulation to meet 1.9 or 2.0 R-Value
Note: H1 Insulation - Internally insulated masonry walls must meet the timber insulation code
STO CONCRETE
BLOCK
STO CONCRETE BLOCK
CB 005
CONSTRUCTION & DETAILING
2014
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STO CONCRETE BLOCK PLASTER SYSTEM
StoArmat Reinforced Plaster System
To combat fractures and stress that can occur in concrete block construction during the curing and
settling process. The StoFlexyl waterproofing membrane is to ensure openings, junctions,
terminations and overlays are waterproofed.
SS202 STOARMAT MIRAL PLASTER SYSTEM BRANZ APPRAISAL CERTIFICATE No.515
INCORPORATING:
1.
2.
3.
4.
Stoflexyl Waterproofing 18Kg pail plus cement evaluated by BRANZ to meet AS/NZS4858
waterproofing membrane requirements as required by NZBC E2/AS1
Levellite Base Plaster 20Kg bag mineral fibre reinforced based plaster with EPS bead for levelling
and straightening walls. Can be machine applied
StoArmat Classic Plaster 23Kg pail European fibre reinforced non-cement based crack resistant
plaster used with European mesh as a reinforcement plaster
Stolit Coloured Finishing Render in 25Kg Pail
Stolit K - 1.0mm Coloured Float Finish Render
1.5mm Coloured Float Finish Render
2.0mm Coloured Float Finish Render
3.0mm Coloured Float Finish Render
Stolit - MP Fine Sponge or Adobe Coloured Finishing Render
MP Natural Sponge or Adobe Coloured Finishing Render
Milano Smooth or Adobe Coloured Finishing Render
STO CONCRETE
BLOCK
STO CONCRETE BLOCK
PLASTER SYSTEM
CB 006
2014
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STOARMAT MIRAL PLASTER
SYSTEM - SS202
BASECOAT: LEVELLITE 6/8mm
PLASTER
REINFORCEMENT: STOARMAT
CLASSIC PLASTER
PLUS: STO EUROPEAN MESH
SKIM COAT: STOARMAT
CLASSIC PLASTER
FINISHING RENDER: STOLIT K
& MP RANGE
STOLIT K COLOURED FINISH RENDER
1.0, 1.5, 2.0 & 3.0mm FLOAT FINISH.
STOLIT MP COLOURED FINISH RENDER
MP, MP NATURAL & MILANO FINE FINISH
COATING/STO COLOR:
:MAXICRYL MATT FACADE PAINT
:LASTIC SATIN FACADE PAINT
:LOTUSAN MINERAL RESIN PAINT
SCALE 1:20
STO CONCRETE
BLOCK
STO CONCRETE BLOCK
CB 100
STOARMAT MIRAL PLASTER SYSTEM - ISOMETRIC
2014
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
CONCRETE MASONRY WALL
INSULATION as per NZBC - H1
50
100mm
150
50
DPC
CONCRETE SLAB/REINFORCING
AS PER NZS 4229 & 4210 OR
ENGINEER SPECIFIC DESIGN
SLAB
INSULATION
DPM
SCALE 1:5
STO CONCRETE
BLOCK
STO CONCRETE BLOCK
CB 200
REBATED SLAB-ON-GROUND
2014
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
CONCRETE
MASONRY WALL
INSULATION as per NZBC - H1
150mm
unpaved
100mm
paved
STOARMAT MIRAL
PLASTER SYSTEM
100mm STOFLEXYL
MESH OVER SLAB TO
BLOCK JUNCTION
STOFLEXYL - BRUSH
SHEETS & FOUNDATION
ADHESIVE MORTAR TO
FACE AND MECHANICAL
FIX @ 600mm CTRS
ABOVE GROUND
SCABBLE SLAB SURFACE
FOR BLOCK BOND
STO FLEXYL
WATERPROOFING
SHALL EXTEND
ABOVE GROUND BY
AT LEAST 150mm AND
IF DPM IS APPLIED
TO THE EXTERNAL
FACE OF FOOTING IT
SHALL OVERLAP BY
AT LEAST 50mm
CONCRETE SLAB/REINFORCING AS PER
NZS 4229 & 4210 OR ENGINEER SPECIFIC
DESIGN
DPM REQUIRED
FOR POORLY
DRAINED SITES
SCALE 1:5
STO CONCRETE
BLOCK
STO CONCRETE BLOCK
CB 201
NON-REBATED SLAB-ON-GROUND
2014
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
CONCRETE MASONRY
WALL
INSULATION as per
NZBC - H1
G.L
50
STOFLEXYL WATERPROOFING
SHALL EXTEND ABOVE GROUND
BY AT LEAST 150mm AND IF DPM
IS APPLIED TO THE EXTERNAL
FACE OF FOOTING IT SHALL
OVERLAP BY AT LEAST 50mm
150
STOARMAT MIRAL
PLASTER SYSTEM
see note
NOTE:
REFER TO NZS 4229 or
SPECIFIC DESIGN FOR
DIMENSION, REINFORCING
AND GROUND CLEARANCES
see note
SCALE 1:10
STO CONCRETE
BLOCK
STO CONCRETE BLOCK
CB 202
STRIP FOOTING DETAIL
2014
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
TRANSITION APPROX.100mm
BELOW GROUND
GRANDULAR FILL
RECOMMENDED
SELECTED BITUMOUS
PEEL & STICK TANKING
MEMBRANE
WITH PROTECTION
MATERIAL
STO CONCRETE
BLOCK
150
100
STOARMAT MIRAL
PLASTER SYSTEM
STOFLEXYL MESHED
WATERPROOFING FROM
150mm ABOVE GROUND
AND DOWN OVER
COMPRESSION BAR
NOTE:
REFER TO NZS 4229 or
SPECIFIC DESIGN FOR
DIMENSION & REINFORCING
TANKING SEALANT
COMPRESSION BAR
MECHANICALLY FIXED TO
CONC.BLOCK
STO CONCRETE BLOCK
CB 203
TANKING TO PLASTER TRANSITION
2014
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
BLOCK CONTROL JOINT
BASECOAT: LEVELLITE 6/8mm
REINFORCEMENT: STOARMAT
CLASSIC
STO 8 mm uPVC JOINT IN
STOARMAT MESH COAT
FINISHING RENDER: STOLIT K
& MP RANGE
VERTICAL CONTROL JOINTS AT BLOCK
CONTROL JOINTS - NORMALLY @6.0M
CENTERS or AS PER PROJECT DRAWINGS
NOTE:
WHEN FITTING THE STO CONTROL JOINT, PULL TAB 75mm OUT TO ENSURE
EASIER REMOVAL. BED JOINT IN STOARMAT CLASSIC MESH COAT. THE
FINISHED JOINT MUST BE COATED FOR NEGATIVE DETAIL or FILLED WITH
MS SEALANT. REMOVE TABS AS SOON AS JOINT IS SET TO AVOID
CRACKING
SCALE 1:20
STO CONCRETE
BLOCK
STO CONCRETE BLOCK
CB 300
VERTICAL CONTROL JOINT
2014
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
100
STOFLEXYL WATERPROOFING 150mm
MIN.ABOVE & BELOW STAIRS WITH 50mm
MIN.UNDER PLASTERED STAIRS or TILE
MEMBRANE
CONCRETE MASONRY
WALL (20 Series shown)
INSULATION AS PER
NZBC - H1
50mm
APPLY STOFLEXYL MESHED BAND ON
CONC.BLOCKS 150mm MIN. ABOVE AND 150mm
BELOW STAIRS BEFORE BOXING - APPLY
STOFLEXYL MESH, 50mm MIN.ONTO STAIRS
ONCE CONCRETE HAS CURED BEFORE
PLASTERING OR APPLYING TILE MEMBRANE
STOFLEXYL WATERPROOFING MEMBRANE
•
•
•
•
•
•
STO CONCRETE
BLOCK
WALL CAPS, PARAPETS, BALUSTRADE TOPS
JOINERY OPENINGS
TIMBER OVERLAYS & SOFFITS
STAIRS
ADJACENT GARDEN WALLS
FOUNDATIONS
STO CONCRETE BLOCK
CB 301
STAIR WATERPROOFING DETAIL
2014
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
CONCRETE MASONRY
WALL (20 Series shown)
STOARMAT MIRAL
PLASTER SYSTEM
INTER-STOREY FLOOR
SLAB - REINFORCING NOT
SHOWN FOR CLARITY
DPC
STOFLEXYL MESH COAT
OVER FLOOR JUNCTION IF
FLOOR SLAB PENETRATES
EXT.CONC.BLOCK
INSULATION AS PER
NZBC - H1
SCALE 1:10
STO CONCRETE
BLOCK
STO CONCRETE BLOCK
CB 302
INTER-STOREY SLAB DETAIL
2014
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
CONCRETE MASONRY WALL
INSULATION AS PER NZBC - H1
5° MIN.SLOPE TO OUTSIDE
SECURE PIPE, APPLY SEALANT
PLASTER AND REAPPLY SEALANT ON
MESH COAT BEFORE FINISHING
PIPE OR OTHER PENETRATION
SLOPED DOWNWARD - TOWARD THE
OUTSIDE
8/10mm SEALANT BEAD ON PEF
ROD BETWEEN PIPE AND PLASTER
INTERIOR
EXTERIOR
SCALE 1:5
STO CONCRETE
BLOCK
STO CONCRETE BLOCK
CB 350
PIPE PENETRATION DETAIL (up to150mm)
2014
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
METER BOX AT HEAD
PROVIDE
AIRSEAL
POLYSTYRENE
INSULATION TO SUIT
APPLY STOARMAT MIRAL PLASTER
SYSTEM WITH STO uPVC DRIP EDGE
AT HEAD
PREPARE REBATES, APPLY TWO (2)
COATS OF STOFLEXYL
WATERPROOFING BEFORE APPLYING
STOARMAT MIRAL SYSTEM. LEAVE
10mm SEALANT JOINT
MS SEALANT OVER STO JOINT
SEAL TAPE TO PERIMETER OF
METERBOX
THICKEN BASECOAT ON REBATES TO
ACHIEVE A 6-8mm FINISHING GAP
BEFORE SEALING
METER BOX AT SILL
PROVIDE
AIRSEAL
MS SEALANT OVER STO
JOINT SEAL TAPE
PREPARE REBATES, AND APPLY
TWO (2) COATS OF STOFLEXYL
WATERPROOFING BEFORE
APPLYING STOARMAT MIRAL
PLASTER SYSTEM. LEAVE 10mm
SEALANT JOINT
STOARMAT MIRAL PLASTER
SYSTEM
SCALE 1:5
STO CONCRETE
BLOCK
STO CONCRETE BLOCK
CB 351
METER BOX
2014
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
CONCRETE MASONRY WALL
INSULATION AS PER NZBC - H1
SLOPE TO
O
UTSIDE
FAN VENT COVER
STOARMAT MIRAL PLASTER
SYSTEM
MS SEALANT TO PERIMETER
LEAVE 40mm DRAINAGE
GAP IN MIDDLE
MS SEALANT AT PIPE
JUNCTION (FIX FAN COVER TO
FLEXIBLE PIPE AS PER
MANUFACTURERS
INSTRUCTION) USE STO JOINT
SEAL TAPE TO SEAL TO
CONCRETE BLOCK
SCALE 1:5
STO CONCRETE
BLOCK
STO CONCRETE BLOCK
CB 352
FAN VENT DETAIL
2014
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
CONCRETE MASONRY WALL
INSULATION AS PER NZBC - H1
STOARMAT MIRAL PLASTER
SYSTEM
ADHESIVE ADHERE
ARCHITECTURAL PROFILES
AND USE STOTHERM FIXINGS
AS NECESSARY
PREMESHED ARCHITECTURAL
PROFILE OVER STOARMAT/MESH
COAT
MESH COAT UNDER PROFILE
SCALE 1:5
STO CONCRETE
BLOCK
STO CONCRETE BLOCK
CB 353
ARCHITECURAL PROFILE
2014
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
75
75
HANDRAIL DESIGN & HEIGHT IN
ACCORDANCE WITH NZBC
HANDRAIL PLATE ON EPDM
GASKET WITH EPDM WASHERS
UNDER FIXING WASHERS
STOFLEXYL MESHED
WATERPROOFING WITH
75mm DOWNTURM OVER
BASECOAT FINISHED IN
STOARMAT MIRAL PLASTER
SYSTEM
SELECTED CONC.BLOCK
SERIES (shown 20 series
conc.block)
METAL OVERFLASHING SEALED INTO
WALL CHASE (20mm x 10mm) & WITH
MASONRY FIXINGS
ROOF MEMBRANE FLASHING
CHASED INTO WALL
SELECTED ROOF
MEMBRANE
ROOF SCREED
TO A FALL MIN FALL1.5°
CONCRETE
ROOF SLAB
INSULATION AS PER
NZBC - H1
SCALE 1:5
STO CONCRETE
BLOCK
STO CONCRETE BLOCK
CB 354
HANDRAIL
2014
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
70
STOARMAT MIRAL
PLASTER SYSTEM
SELECTED CONC.BLOCK SERIES
(shown 20 series conc.block)
PROPRIETARY SCUPPER
OUTLET - CUT TO SUIT
REBATE INTO
SUBSTRATE
STO uPVC FINISHING
EDGE TO PLASTER
METAL OVER-FLASHING
TO BE CHASED AND
SEALED INTO WALL
WITH MS SEALANT
SELECTED MEMBRANE
low point
50mm DRIP EDGE
BACKING ROD & STO SEAL
JOINT INSTALLED AROUND
PERIMETER OF OPENING
SECURE RWH WITH MASONRY
FIXINGS WITH EDPM WASHER
BETWEEN RWH AND STO
PLASTER FINISH
MASONRY
FIXING
CUSTOM FOLDED RAIN
WATER HEAD
DEBRIS SCREEN
H3.1 JOISTS,
LAID TO A FALL
INSULATION AS
PER NZBC - H1
SCALE 1:5
STO CONCRETE
BLOCK
STO CONCRETE BLOCK
CB 355
RWH/SCUPPER OPENING
2014
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
HEAD DETAIL
PREPARE REBATES AND
BRUSH APPLY TWO (2)
COATS OF STO FLEXYL
WATERPROOFING TO
HEAD & JAMB REBATES
BEFORE INSTALLING
JOINERY
20 SERIES CONCRETE
MASONRY WALL
INSULATION AS
PER NZBC - H1
5
STO PREMESHED
DRIP EDGE AT HEAD
MS SEALANT
CONTINUOUS ACROSS
HEAD & DOWN JAMBS
SILL DETAIL
5
5
BRUSHED STOFLEXYL
COAT
20 SERIES CONCRETE
MASONRY WALL
10
PROPRIETARY
ALU.WINDOW JOINERY
PREPARE REBATES AND
APPLY STO FLEXYL MESHED
WATERPROOFING TURNED
40mm UP JAMBS
REMOVE
PROJECTING SILL
(as requested) SHOWN DASHED
STOARMAT MIRAL
PLASTER SYSTEM
INSULATION AS
PER NZBC - H1
SCALE 1:5
STO CONCRETE
BLOCK
STO CONCRETE BLOCK
CB 400
ALUMINIUM JOINERY - HEAD & SILL DETAIL
2014
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
INSULATION AS PER
NZBC - H1
20 SERIES CONCRETE
MASONRY WALL - REINFORCED
AS PER NZS 4229
5
PROPRIETARY
ALU.WINDOW JOINERY
STOARMAT MIRAL
PLASTER SYSTEM
MS SEALANT CONTINUOUS AROUND
HEAD & JAMBS
PREPARE REBATES; BRUSH APPLY
TWO (2) COATS OF STO FLEXYL
WATERPROOFING TO JAMB & HEAD
REBATES BEFORE INSTALLING
JOINERY
SCALE 1:5
STO CONCRETE
BLOCK
STO CONCRETE BLOCK
CB 401
ALUMINIUM JOINERY - JAMB DETAIL
2014
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
20 SERIES
CONCRETE
MASONRY WALL
INSULATION AS PER
NZBC - H1
PREPARE REBATES AND BRUSH
APPLY TWO (2) COATS OF STO
FLEXYL WATERPROOFING TO
ALL REBATES BEFORE
INSTALLING JOINERY
5
STO PREMESHED DRIP EDGE
MS SEALANT CONTINUOUS
AROUND HEAD & JAMBS
LINE OF CONCRETE
BLOCK & FOUNDATION SHOWN DASHED
10mm MIN.
TIMBER SILL - ADJUST
PACKER TO SUIT FLOOR
COVERINGS
5mm
PROPRIETARY ALU.DOOR
JOINERY
PREPARE REBATES AND
BRUSH APPLY STO FLEXYL
WATERPROOFING
STOARMAT MIRAL
PLASTER SYSTEM 150mm MIN.FLOOR SLAB
to GROUND LEVEL
100mm MIN.FLOOR SLAB
to PAVING
SCALE 1:5
STO CONCRETE
BLOCK
STO CONCRETE BLOCK
CB 402
ALU.JOINERY-DOOR HEAD & THRESHOLD DETAIL
2014
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
INSULATION AS PER
NZBC - H1
20 SERIES
CONCRETE BLOCK
AIRSEAL ON PEF ROD GAP
7.5-8mm APPROX & PACKER
5
STOARMAT MIRAL
PLASTER SYSTEM
PROPRIETARY ALU.DOOR
JOINERY
MS SEALANT CONTINUOUS
AROUND HEAD & JAMBS
PREPARE REBATES AND BRUSH
APPLY TWO (2) COATS OF STO
FLEXYL WATERPROOFING TO
ALL REBATES BEFORE
INSTALLING JOINERY
SCALE 1:5
STO CONCRETE
BLOCK
STO CONCRETE BLOCK
CB 403
ALUMINIUM JOINERY - JAMB DETAIL
2014
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STOARMAT MIRAL
PLASTER SYSTEM
20 SERIES CONCRETE
MASONRY WALL
PREPARE REBATES AND BRUSH
APPLY TWO (2) COATS OF STO
FLEXYL WATERPROOFING TO ALL
REBATES BEFORE INSTALLING
JOINERY ON DPC & PLASTERING
STO PREMESHED DRIP EDGE
INSULATION AS
PER NZBC - H1
AIR SEAL OVER
BACKING ROD
MS SEALANT CONTINUOUS
ACROSS HEAD & DOWN
JAMBS. TIMBER TRIM
TIMBER JOINERY PROFILES
AS PER NZS 3610
PREPARE REBATES AND
BRUSH APPLY STO FLEXYL TO
INTERNAL REBATE WITH MESH
WATERPROOFING TURNED
40mm UP JAMBS OVER SILL
H3.2 TIMBER PACKER ON
DPC UNDER SILL
INSULATION AS
PER NZBC - H1
REMOVE
PROJECTING SILL SHOWN DASHED
20 SERIES CONCRETE
MASONRY WALL
STOARMAT MIRAL
PLASTER SYSTEM
SCALE 1:5
STO CONCRETE
BLOCK
STO CONCRETE BLOCK
CB 404
TIMBER JOINERY - HEAD & SILL DETAIL
2014
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
INSULATION/STAPPING
AND LINING
20 SERIES CONCRETE
MASONRY WALL
AIR SEAL OVER
BACKING ROD
MS SEALANT CONTINUOUS
ACROSS HEAD & JAMBS,
TIMBER TRIM
STOARMAT MIRAL
PLASTER SYSTEM
PREPARE REBATES AND BRUSH
APPLY STO FLEXYL MESHED
WATERPROOFING TURNED 40mm
UP JAMBS
SCALE 1:5
STO CONCRETE
BLOCK
STO CONCRETE BLOCK
CB 405
TIMBER JOINERY - JAMB DETAIL
2014
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
20 SERIES
CONCRETE BLOCK
STOARMAT MIRAL
PLASTER SYSTEM
50
INSULATION/STAPPING AND
LINING
AIR SEAL OVER
BACKING ROD
APPLY TWO (2) COATS OF STO
FLEXYL WATERPROOFING TO
ALL REBATES OVER BASE
COAT 50mm MIN.UP FACE OF
MASONRY WALL
STO PREMESHED DRIP EDGE
SEALANT OVER BOND
BREAKER CONTINUOUS
ACROSS HEAD & JAMB
LINE OF CONCRETE
BLOCK & FOUNDATION SHOWN DASHED
50
* REBATE TO SUIT
SILL PROFILE
*
TIMBER DOOR JOINERY
PROFILES AS PER NZS 3610
APPLY TWO COATS OF STO
FLEXYL WATERPROFFING TO
ALL REBATES OVER BASECOAT
50mm MIN.DOWN WALL
SCALE 1:5
STO CONCRETE
BLOCK
STO CONCRETE BLOCK
CB 406
TIMBER DOOR JOINERY - HEAD & SILL DETAIL
2014
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
INSULATION/STAPPING AND
LINING (indicative only, not
req.for weathertightness)
20 SERIES
CONCRETE BLOCK
AIRSEAL ON PEF ROD GAP
7.5-8mm APPROX & PACKER
TIMBER DOOR JOINERY
PROFILES AS PER NZS 3610
50
STOARMAT MIRAL
PLASTER SYSTEM
ALU.EQUAL ANGLE
SEALANT OVER BOND BREAKER
CONTINUOUS ACROSS HEAD & JAMB
APPLY TWO COATS OF STO
FLEXYL WATERPROFFING TO
ALL REBATES OVER BASECOAT
50mm MIN.DOWN WALL
SCALE 1:5
STO CONCRETE
BLOCK
STO CONCRETE BLOCK
CB 407
TIMBER DOOR JOINERY - JAMB DETAIL
2014
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
50
50
METAL CAPPING WITH 5°
MIN.FALL TO PARAPET MASONRY FIXINGS
5°
PROVIDE SEPARATION (ROOF
UNDERLAY) UNDER METAL CAPPING
OVER 9mm H3 PLY ON DPC
SELECTED CONC.BLOCK
SERIES (shown 20 series
conc.block)
STOARMAT MIRAL
PLASTER SYSTEM
NOTE: CUT BLOCK TO SUIT OR BASECOAT PLASTER
TO A FALL APPROX.18mm FROM FRONT EDGE BEFORE
INSTALLING PLYWOOD ON DPC. ALTERNATIVELY USE
H3.1 TIMBER PLATE, MAINTAINING FLASHING COVER
OVER CONC.BLOCK OF 50mm MIN.
SCALE 1:5
STO CONCRETE
BLOCK
STO CONCRETE BLOCK
CB 500
PARAPET/METAL FLASHING DETAIL
2014
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
75
75
10°
STOFLEXYL MEMBRANE
UNDER MESH COAT TO TOP &
SIDES, 75mm DOWNTURN
OVER LEVELITE BASE COAT
CUT CONC.BLOCK TO FORM
REQUIRED SLOPE OF 10° MIN.
SELECTED CONC.BLOCK SERIES
(shown 20 series conc.block)
STOARMAT MIRAL
PLASTER SYSTEM
NOTE: CUT BLOCKS TO SUIT or BASECOAT PLASTER TO
A FALL 10° MIN.FOR STOCLEAR COATING SYSTEM REFER TO DRAWING DETAIL CB 502
SCALE 1:5
STO CONCRETE
BLOCK
STO CONCRETE BLOCK
CB 501
PLASTERED PARAPET/BALUSTRADE DETAIL
2014
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
15
5
STOFLEXYL MESHED
WATERPROOFING
MORTAR BED 15mm 5mm FALL TO
INTERIOR SIDE
SELECTED CONC.BLOCK
SERIES (shown 20 series
conc.block)
PAINTED, CLEAR COATED
or PLASTERED FINISH
SCALE 1:5
STO CONCRETE
BLOCK
STO CONCRETE BLOCK
CB 502
UNCOATED,PAINTED CLEAR COATED or PLASTERED
2014
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
10°
75
75
CUT CONCRETE BLOCK TO FORM
REQUIRED SLOPE OF 10° MIN.
STOFLEXYL MEMBRANE UNDER MESH
COAT TO TOP & SIDES, 75mm DOWNTURN
OVER LEVELITE BASE COAT
SELECTED CONC.BLOCK SERIES
(shown 20 series conc.block)
STOARMAT MIRAL
PLASTER SYSTEM
STO STICK ON CONNECTOR OR STO
uPVC FINISHING EDGE & MS
SEALANT AT FLASHING
150
SELECTED ROOF
MEMBRANE
70
METAL OVERFLASHING SEALED INTO
WALL CHASE (20mm x 10mm) & FIXED
WITH A MASONRY FIXINGS
SELECTED ROOF MEMBRANE
UPSTAND150mm MIN.
ROOF SCREED TO A
MIN FALL1.5°
CONCRETE
ROOF SLAB
INSULATION AS PER
NZBC - H1
SCALE 1:5
STO CONCRETE
BLOCK
STO CONCRETE BLOCK
PARAPET/ROOF/WALL DETAIL
CB 503
2014
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
SELECTED CONC.BLOCK SERIES
(shown 20 series conc.block)
75
LEVELLITE BASECOAT
OVERLAY OF STOFLEXYL MESHED
WATERPROOFING TO TOP & SIDES
- 75mm DOWNTURN OVER BASE
COAT
NOTE:
1. ALL ADJACENT WALLS ARE TO BE STRUCTURALLY TIED WITH
STEEL REINFORCEMENT.
2. BALUSTRADES TO HAVE 10° MIN.FALL TO TOP
3. ALL BALUSTRADES/PARAPETS & WALL CAPS TO HAVE STOFLEXYL
MESHED WATERPROOFING
4. STO FLEXYL MESHED WATERPROOFING MEMBRANE HAS BEEN
TESTED BY BRANZ TO AS/NZS4858 - AS REQUIRED BY E2/AS1 &
CCANZ CP01:2014
SCALE 1:20
STO CONCRETE
BLOCK
STO CONCRETE BLOCK
CB 504
STOFLEXYL WATERPROOFING MEMBRANE
2014
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
PRE FINISHED METAL
ROOFING OVER ROOF
UNDERLAY
60mm
50 mm
H3.1 PRE PRIMED &
PAINTED
FASCIA/BARGE
BOARD
MIN.COVER
M12 BOLT FIXING
SOFFIT FRAMING
SOFFIT LINING
MS SEALANT 6-8mm,
WATERPROOF
CONC.BLOCK BEFORE
INSTALLING SOFFIT
STOARMAT MIRAL
PLASTER SYSTEM TO
TOP OF WALL
20 SERIES CONCRETE
MASONRY WALL
INSULATION AS
PER NZBC - H1
NOTE: EAVE FLASHING REQUIRED WHERE
•
ROOF SLOPE LESS THAN OR EQUAL TO 10°
•
SOFFIT WIDTH LESS THAN OR EQUAL TO 100mm
•
WIND ZONES ARE VERY HIGH or EXTRA HIGH
SCALE 1:5
STO CONCRETE
BLOCK
STO CONCRETE BLOCK
CB 600
EAVES WITH OVERHANG
2014
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
125
COMPLIANT EAVE
FLASHING/E2/AS1
PRE FINISHED METAL
ROOFING OVER ROOF
UNDERLAY
35
PURLIN - REFER
NZS 3604
50 mm
H3.1 PRE PRIMED &
PAINTED FASCIA/BARGE
BOARD
MIN.COVER
M12 BOLT FIXING
STOARMAT MIRAL
PLASTER SYSTEM TO
TOP OF WALL
20 SERIES CONCRETE
MASONRY WALL
INSULATION AS PER
NZBC - H1
NOTE: EAVE FLASHING REQUIRED WHERE
•
ROOF SLOPE LESS THAN OR EQUAL TO 10°
•
SOFFIT WIDTH LESS THAN OR EQUAL TO 100mm
•
WIND ZONES ARE VERY HIGH or EXTRA HIGH, MS
SEALANT REQUIRED
SCALE 1:5
STO CONCRETE
BLOCK
STO CONCRETE BLOCK
CB 601
EAVES WITH NO OVERHANG
2014
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
PRE FINISHED METAL
ROOFING OVER ROOF
UNDERLAY
PURLIN - REFER NZS 3604
PRE FINISHED METAL
FLASHING
LAP - REFER NZBC, TABLE 7
MIN.2 x crests
E2/AS1
50/90
RAFTER - REFER NZS 3604
FOR SIZE
BOLT FIXING
FLYING RAFTER
OUTRIGGER
RAKING WALL
PLATE ON DPC
SOFFIT LINING
H3.1 PRE PRIMED &
PAINTED FASCIA/BARGE
BOARD
20 x 20mm SCOTIA BEAD
STO 6mm FINISHING EDGE
STOARMAT MIRAL
PLASTER SYSTEM
20 SERIES CONCRETE
MASONRY WALL
INSULATION AS
PER NZBC - H1
SCALE 1:5
STO CONCRETE
BLOCK
STO CONCRETE BLOCK
CB 602
BARGE WITH OVERHANG
2014
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
75
35
110mm Upstand for flashing
STOFLEXYL MESHED
WATERPROOFING 75mm
MIN.DOWNTURN OVER BASECOAT
STO uPVC FINISHING EDGE TO
PLASTER AND MS SEALANT AT
FLASHING JUNCTION
METAL OVER-FLASHING TO BE
CHASED AND SEALED INTO
WALL WITH MS SEALANT
PROFILED ROOF FLASHING &
UNDERLAY TO RUN UP BENEATH
OVER-FLASHING AND TO BE
MECHANICALLY FIXED TO WALL
PURLIN - REFER
NZS 3604
RAFTER - REFER NZS
3604 FOR SIZE
SELECTED CONC.BLOCK
SERIES (shown 20 series
conc.block)
STOARMAT MIRAL
PLASTER SYSTEM
INSULATION/STAPPING
AND LINING
SCALE 1:5
STO CONCRETE
BLOCK
STO CONCRETE BLOCK
CB 603
ROOF TO CONC.BLOCK GABLE END
2014
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
PRE FINISHED METAL
ROOFING OVER ROOF
UNDERLAY
50
SELECTED FIBRE
CEMENT SOFFIT LINING
6mm MAX.GAP WITH MS SEALANT
or STO JOINT SEAL TAPE
BRUSH STOFLEXYL
WATERPROOFING TO CONC.BLOCK
- 50mm MIN. PAST SOFFIT
STOARMAT MIRAL
PLASTER SYSTEM
NOTE:
MAX.ANGLE OF SOFFIT RESTRICTED TO
BETWEEN 91° - 115°
•
SOFFITS ARE FIXED AFTER PLASTERING
20 SERIES CONCRETE
MASONRY WALL
INSULATION/STAPPING
AND LINING
•
STO CONCRETE
BLOCK
SCALE 1:10
STO CONCRETE BLOCK
CB 604
RAKING SOFFIT (REVERSED)
2014
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
75
35
110mm Upstand for flashing
STOARMAT MIRAL
PLASTER SYSTEM
STO uPVC FINISHING EDGE TO
PLASTER WITH MS SEALANT
METAL OVER-FLASHING TO BE CHASED
AND SEALED INTO WALL WITH MS SEALANT
SECURED WITH MASONRY FIXINGS
Refer E2/AS1 table 7
PROFILED ROOF APRON
FLASHING & ROOF UNDERLAY TO
RUN UP BEHIND FLASHING
TIMBER ROOF STRUCTURE
NOTE: INSTALL DIVERTER FLASHING
AT ROOF/GUTTER JUNCTION
SCALE 1:5
STO CONCRETE
BLOCK
STO CONCRETE BLOCK
CB 700
GABLE END/ROOF JUNCTION
2014
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
75
35
110mm Upstand for flashing
STO uPVC FINISHING EDGE TO
PLASTER WITH MS SEALNT
METAL OVER-FLASHING TO BE CHASED
AND SEALED INTO WALL WITH MS SEALANT
SECURED WITH MASONRY FIXINGS
Refer
PROFILED ROOF, APRON
E2/AS
1 Tab
FLASHING & ROOF UNDERLAY TO
le 7
RUN UP BEHIND FLASHING
TIMBER ROOF STRUCTURE
NOTE:
ENSURE APRON FLASHING IS OVER
FLASHED AT BOTH ENDS
SCALE 1:5
STO CONCRETE
BLOCK
STO CONCRETE BLOCK
CB 701
APRON FLASHING
2014
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
20mm
75
35
110mm Upstand for flashing
STOARMAT MIRAL
PLASTER SYSTEM
STO uPVC FINISHING EDGE TO
PLASTER WITH MS SEALANT
METAL OVER-FLASHING TO BE CHASED
AND SEALED INTO WALL WITH MS SEALANT
SECURED WITH MASONRY FIXINGS
80mm 80mm
TIMBER ROOF
STRUCTURE
SCALE 1:5
STO CONCRETE
BLOCK
STO CONCRETE BLOCK
CB 702
PARALLEL ROOF/HIDDEN GUTTER
2014
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
MIN. 5mm RADIUS
TO PLYWOOD
50mm MIN.LAP REFER E2/AS1
S/S ANGLE
50
SELECTED MEMBRANE FINISH OVER H3"C" FACED
PLYWOOD LAID TO A 1:30MIN.FALL GLUE & SCREW
TO TIMBER FRAMING, ALL EDGES SUPPORTED
H3.1 PRE PRIMED & PAINTED
FASCIA/BARDGE BOARD MS
SEALANT ON STO SEAL TAPE
50
COVER
PRE FINISHED
METAL SPOUTING
AND BRACKETS
INSULATION AS PER
NZBC - H1
20 SERIES CONCRETE
MASONRY WALL
STOARMAT MIRAL
PLASTER SYSTEM
SCALE 1:5
STO CONCRETE
BLOCK
STO CONCRETE BLOCK
CB 703
FACE FIXED FASCIA/MEMBRANE ROOF
2014
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
STOARMAT MIRAL
PLASTER SYSTEM
SELECTED CONC.BLOCK SERIES
(shown 20 series conc.block)
INSULATION AS PER NZBC
- H1
50mm MIN.COVER
E2/AS1 COMPLIANT BACK
FLASHING WITH MS SEALANT
NOMINAL H3.1 TIMBER
BATTEN
SELECTED HORIZONTAL
TIMBER WEATHERBOARDS
OVER 20mm DRAINED CAVITY
WALL UNDERLAY
SCALE 1:5
STO CONCRETE
BLOCK
STO CONCRETE BLOCK
EXTERNAL CORNER
CB 800
2014
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
INSULATION AS PER
NZBC - H1
SELECTED CONC.BLOCK
SERIES (shown 20 series
conc.block)
STO uPVC FINISHING EDGE
WITH MS SEALANT
NOMINAL H3.1
TIMBER BATTEN
SELECTED HORIZONTAL
TIMBER WEATHERBOARDS
OVER 20mm DRAINED CAVITY
50mm MIN.COVER
STOARMAT MIRAL
PLASTER SYSTEM
E2/AS1 COMPLIANT
FLASHING IN
CONC.BLOCK CHASE
SCALE 1:5
STO CONCRETE
BLOCK
STO CONCRETE BLOCK
INTERNAL CORNER
CB 801
2014
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
SELECTED FLOORING
SELECTED HORIZONTAL
TIMBER
WEATHERBOARDS OVER
20mm DRAINED CAVITY
WALL UNDERLAY
JOISTS - REFER
NZS3604:2011 FOR SIZE
15
50
WALL PLATE ON
DPC
CAVITY CLOSURE
STOARMAT MIRAL PLASTER
SYSTEM WITH STO uPVC
FINISHING EDGE
SELECTED CONC.BLOCK SERIES
(shown 20 series conc.block)
INSULATION/STAPPING
AND LINING
SCALE 1:5
STO CONCRETE
BLOCK
STO CONCRETE BLOCK
CB 802
HORIZONTAL JUNCTION/WEATHERBOARD
2014
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
SELECTED CONC.BLOCK
SERIES (shown 20 series
conc.block)
STOARMAT MIRAL
PLASTER SYSTEM
E2/AS1 COMPLIANT FLASHING
REBATED IN CHASE CUT INTO
CONCRETE BLOCK
MS SEALANT OVER
PEF ROD
FLASHING (SPECIFY COATING)
INSULATION AS
PER NZBC - H1
PROFILED FOAM CLOSURE
STRIP UNDER CLADDING
NOMINAL H3.1 TIMBER
BATTEN
HORIZONTAL PROFILED METAL
WALL CLADDING
SCALE 1:5
STO CONCRETE
BLOCK
STO CONCRETE BLOCK
CB 850
EXTERNAL CORNER HORIZ.PROFILED METAL
2014
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
SELECTED INTERNAL
LININGS
DPC
INSULATION AS PER
NZBC - H1
SELECTED CONC.BLOCK
SERIES (shown 20 series
conc.block)
STOARMAT MIRAL SYSTEM
MS SEALANT OVER PEF ROD
PURPOSE MADE FLASHING
(SPECIFY COATING)
PROFILED FOAM CLOSURE
STRIP UNDER CLADDING
27mm MIN.COVER
E2/AS1 COMPLIANT BACK
FLASHING CHASED INTO
CONC.BLOCK
NOMINAL H3.1 TIMBER
BATTEN
HORIZONTAL PROFILED METAL
WALL CLADDING
SCALE 1:5
STO CONCRETE
BLOCK
STO CONCRETE BLOCK
CB 851
INTERNAL CORNER HORIZ.PROFILE METAL
2014
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
SELECTED
FLOORING
HORIZONTAL PROFILED
METAL CLADDING
WALL UNDERLAY
20mm DRAINED &
VENTED CAVITY
JOISTS - REFER
NZS3604 FOR SIZE
WALL PLATE ON
DPC
CLOSE CAVITY VENTED
E2/AS1 COMPLIANT
FLASHING
15
50
CEILING
BATTENS
STOARMAT MIRAL PLASTER
SYSTEM WITH STO uPVC
FINISHING EDGE
SELECTED CONC.BLOCK SERIES
(shown 20 series conc.block)
INSULATION AS PER
NZBC - H1
SCALE 1:5
STO CONCRETE
BLOCK
STO CONCRETE BLOCK
CB 852
HORIZONTAL JUNCTION/HORIZ.PROFILED METAL
2014
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
SELECTED CONC.BLOCK
SERIES (shown 20 series
conc.block)
DPC
INSULATION AS PER
NZBC - H1
20
STOARMAT MIRAL
PLASTER SYSTEM
E2/AS1 COMPLIANT BACK
FLASHING
MS SEALANT
OVER PEF ROD
VERTICAL PROFILED
METAL WALL CLADDING
SCALE 1:5
STO CONCRETE
BLOCK
STO CONCRETE BLOCK
CB 853
EXTERNAL CORNER VERTICAL.PROFILED METAL
2014
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
INSULATION AS PER
NZBC - H1
SELECTED INTERNAL
LININGS
STOARMAT MIRAL PLASTER
SYSTEM
50
SELECTED CONC.BLOCK
SERIES (shown 20 series
conc.block)
E2/AS1 COMPLIANT BACK
FLASHING CHASED INTO
CONC.BLOCK
MS SEALANT JOINT OVER
PEF ROD
VERTICAL PROFILED METAL WALL
CLADDING
SCALE 1:5
STO CONCRETE
BLOCK
STO CONCRETE BLOCK
CB 854
INTERNAL CORNER VERTICAL PROFILE METAL
2014
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
SELECTED
FLOORING
VERTICAL PROFILED
METAL CLADDING
WALL UNDERLAY
JOISTS - REFER
NZS3604 FOR SIZE
WALL PLATE ON
DPC
50
CEILING
BATTENS
3.5
6
3.5mm VENTILATION GAP,
NON VENTED CLOSER
FLASHING
STOARMAT MIRAL
PLASTER SYSTEM WITH
STO uPVC FINISHING EDGE
SELECTED CONC.BLOCK SERIES
(shown 20 series conc.block)
INSULATION AS
PER NZBC - H1
SCALE 1:5
STO CONCRETE
BLOCK
STO CONCRETE BLOCK
CB 855
HORIZ.JUNCTION/VERTICAL PROFILED METAL
2014
The information contained in this detail is based on our experience and testing and represents the latest information available at the date of
issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be
used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the
responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.
Download