Drawing Description STO DRAWING REGISTER Drawing No. Drawing Register CB 001 - 002 Introduction Series 000 Sto Concrete Block Construction & Detailing Sto Concrete Block Construction & Detailing Sto Concrete Block Construction & Detailing Sto Concrete Block Plaster System CB 003 CB 004 CB 005 CB 006 Block Layout Series 100 Sto Concrete Block Stoarmat Miral System - Isometric CB 100 Foundation Series 200 Sto Concrete Block Rebated Slab-on-Ground Sto Concrete Block Non-Rebated Slab-on-Ground Sto Concrete Block Strip Footing Detail Sto Concrete Block Tanking to Plaster Transition CB 200 CB 201 CB 202 CB 203 Walls Series 300 Sto Concrete Block Vertical Control Joint Sto Concrete Block Stair Waterproofing Detail Sto Concrete Block Inter-Storey Slab Detail CB 300 CB 301 CB 302 Wall Penetrations & Fittings Series 350 Sto Concrete Block Pipe Penetration (up to 150mm Ø) Detail Sto Concrete Block Meterbox Sto Concrete Block Fan Vent Detail Sto Concrete Block Architectural Profile Sto Concrete Block Handrail Sto Concrete Block RWH/Scupper Opening CB 350 CB 351 CB 352 CB 353 CB 354 CB 355 Joinery Series 400 Sto Concrete Block Alu.Joinery - Head & Sill Detail Sto Concrete Block Alu.Joinery - Jamb Detail Sto Concrete Block Alu.Entry Door Head & Threshold Detail Sto Concrete Block Alu.Entry Door Jamb Detail Sto Concrete Block Timber Joinery - Head & Sill Detail Sto Concrete Block Timber Joinery - Jamb Detail Sto Concrete Block Timber Entry Door Head & Threshold Detail Sto Concrete Block Timber Entry Door Jamb Detail CB 400 CB 401 CB 402 CB 403 CB 404 CB 405 CB 406 CB 407 Parapets, Balustrades, Decks Series 500 Sto Concrete Block Parapet/Metal Flashing Detail Sto Concrete Block Plastered Parapet/Balustrade Detail Sto Concrete Block Uncoated, Painted, Clear Coated or Plastered Parapet Detail Sto Concrete Block Parapet/Roof/Wall Detail Sto Concrete Block StoFlexyl Waterproofing Membrane - Isometric CB 500 CB 501 CB 502 CB 503 CB 504 THESE DETAILS ARE ISSUED AS A GUIDE INCORPORATING STANDARD BUILDING PRACTICES. ALWAYS REFER TO MANUFACTURERS CURRENT DETAILS AND SPECIFICATIONS. THE SEQUENCE OF WORK COVERS VARIOUS BUILDING COMPONENTS, EACH TRADE IS RESPONSIBLE TO ENSURE THEIR ELEMENTS ARE FULLY INCBALLED INCLUDING ALL WATERPROOFING/SEALANT/ FLASHINGS AS IS APPLICABLE. PAGE 1 OF 2 STO CONCRETE BLOCK STO CONCRETE BLOCK CB 001 DRAWING REGISTER 2014 The information contained in this detail is based on our experience and testing and represents the latest information available at the date of issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications. Drawing Description STO DRAWING REGISTER Drawing No. Soffit Series 600 Sto Concrete Block Eaves with Overhang Sto Concrete Block Eaves without Overhang Sto Concrete Block Barge with Overhang Sto Concrete Block Roof to Conc.Block Gable End Sto Concrete Block Raking Soffit (Reversed) CB 600 CB 601 CB 602 CB 603 CB 604 Roof Series 700 Sto Concrete Block Gable End/Roof Junction Sto Concrete Block Apron Flashing Sto Concrete Block Parallel Roof/Hidden Gutter Sto Concrete Block Face Fixed Fascia/Membrane Roof CB 700 CB 701 CB 702 CB 703 Dissimilar Material Bevel-Back Weatherboard Series 800 Sto Concrete Block Ext.Corner Sto Concrete Block Int.Corner Sto Concrete Block Horizontal Junction CB 800 CB 801 CB 802 Brick Series 810 series not issued Fibre Cement Sheet Series 820 series not issued Manufactured Stone - Schist & Natural Stone Series 840 series not issued Profile Metal Series 850 Sto Concrete Block Ext.Cnr Horiz.Profiled Metal Sto Concrete Block Int.Cnr Horiz.Profiled Metal Sto Concrete Block Horizontal Junction Horiz.Profiled Metal Sto Concrete Block External Corner Vertical Profiled Metal Sto Concrete Block Internal Corner Vertical Profiled Metal Sto Concrete Block Horiz.Junction Vertical Profiled Metal CB 850 CB 851 CB 852 CB 853 CB 854 CB 855 Stotherm Panel EIPS 860 series not issued DISSIMILAR JOINERY Series 870 series not issued THESE DETAILS ARE ISSUED AS A GUIDE INCORPORATING STANDARD BUILDING PRACTICES. ALWAYS REFER TO MANUFACTURERS CURRENT DETAILS AND SPECIFICATIONS. THE SEQUENCE OF WORK COVERS VARIOUS BUILDING COMPONENTS, EACH TRADE IS RESPONSIBLE TO ENSURE THEIR ELEMENTS ARE FULLY INCBALLED INCLUDING ALL WATERPROOFING/SEALANT/ FLASHINGS AS IS APPLICABLE. PAGE 2 OF 2 STO CONCRETE BLOCK STO CONCRETE BLOCK CB 002 DRAWING REGISTER 2014 The information contained in this detail is based on our experience and testing and represents the latest information available at the date of issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications. SILL BLOCKS SHOULD BE FILLED. CREATE OPENING TO ENABLE BLOCK MORTAR TO FLOW THROUGH. REMOVE PROJECTING SILL FOR A FLUSH FINISH ENSURE CONC.BLOCK WALLS ARE SUPPORTED DURING CONSTRUCTION 45mm MIN.REBATE IS RECOMMENDED MORTAR = 10mm +/- 3mm ALLOW MORTAR JOINTS TO BE TOOL COMPRESSED A NON-REBATED FOUNDATION REQUIRES 100mm STO FLEXYL MESHED WATERPROOFING STRIP CENTERED OVER FLOOR JOINT NOTE: 1. MAIN CONTRACTOR IS TO ENSURE SEPARATE WALLS, STAIRS or DISSIMILAR MATERIAL AGAINST BLOCKWORK ARE WATERPROOFED AS NECESSARY TO FORM A WATERTIGHT CONNECTION WITH THE STO PLASTER SYSTEM 2. IT IS CRITICAL IN PARTIALLY FILLED BLOCKS THAT JOINTS ARE TOOLED FOR EARTHQUAKE RESISTANCE 3. MASONRY CONCRETE BLOCKS as per NZS4210 / 4229 &4230 or SPECIFIC ENGINEER DESIGN 4. ALLOW ADEQUATE TIME FOR BLOCKS TO DRY/STABILISE BEFORE PLASTERING. IN NORMAL DRYING CONDITIONS 4-8 WEEKS 5. CONTROL JOINTS - REFER ENGINEERS SPECIFICATION, BLOCK MANUFACTURERS RECOMMENDATION or NZS4229 SCALE 1:20 STO CONCRETE BLOCK STO CONCRETE BLOCK CB 003 CONSTRUCTION & DETAILING 2014 The information contained in this detail is based on our experience and testing and represents the latest information available at the date of issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications. CONCRETE BLOCK CONSTRUCTION & DETAILING Responsibility All work in this section shall be the responsibility of the Main Contractor. All concrete block construction must be in accordance with the project drawings, specifications and block manufactures technical data. The Main Contractor is to ensure they are fully conversant with all Sto standard installation and fixing details (Sto ACAD details www.sto.co.nz) and their responsibilities before the block works commences. The Main Contractor is also responsible for all liaison with the various sub contractors to ensure that all items or elements affecting the Sto Plaster System are correctly detailed before installing the StoArmat Miral Plaster System. Concrete Blocks The concrete block installation including reinforcement and concrete infill shall be made in strict accordance with the project drawings, specifications and the block manufactures technical documentation. In particular the blocks shall be laid true in both vertical and horizontal planes with all joinery and service openings correctly formed and waterproofed in accordance with Sto details. Control joints must be installed as per the projects structural drawings or manufactures details to manage shrinkage and structural stress. The ground floor slab to block junction should be rebated to provide waterproofing and inter-storey floors should be poured within the block structure leaving the outer block shell to continue to avoid cracking. At least 28 days should be allowed after concrete placement - as per AS/NZS 2311:2000 for curing and stabilization to take place before commencing the StoArmat Miral Plaster System. All maximum tolerances shall be in strict accordance with NZS4210:2001 2.7.1.4, Table 2.2 IE: no more than 3mm surface alignment deviation over a 1200mm radius. The concrete blocks shall be clean, dry and free of all surface contaminants before plastering and the Main Contractor is to ensure that any area or details adjacent to the Sto Plaster System have been adequately waterproofed or flashed to avoid any water migration behind the plaster system. Construction Block Construction • • • • • • • • • • • • • A rebate is recommended in foundations for residential projects unless an exterior insulation system is detailed. Joinery openings are to be formed using rebated blocks & sill blocks (cut sill flush as required). Blocks should be covered on site and laid dry. Vertical control joints are placed at 6.0M max.centres - refer project documentation and NZS4229 for placement and detailing. Mortar to be 12.5MPa min.tool smooth and compressed as per NZS4210 Manufacturers bagged mortar is recommended to meet the specifications Mortar to full depth of webbing up to 20MM thick in first course and then 10MM +/- 3mm Washout ports required to remove mortar droppings from foundation Ensure there is no impediment to grout flow, remove ends or biscuits to prevent air pockets Stack bonded, column blocks and insulation block voids may need to be grouted by the block layer during laying process to ensure a solid fill is achieved Blocks should be filled in 1.2 lifts and mechanically vibrated to avoid air voids and subsequence efflorescence Sill block should be filled by leaving one sill block out to avoid air entrapment Remove any grout slurry from block faces before it sets STO CONCRETE BLOCK STO CONCRETE BLOCK CB 004 CONSTRUCTION & DETAILING 2014 The information contained in this detail is based on our experience and testing and represents the latest information available at the date of issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications. CONCRETE BLOCK CONSTRUCTION & DETAILING......cont. Construction Block Construction • • • • Drying times vary according to block thickness, grout and weather. A min.28days is required for settlement & curing - the blocks must be completely dry before coating Where occupied walls are back filled a 50 year tanking membrane is required. Always waterproof blocks behind or adjacent to any overlays or abutments such as concrete staircases, separate adjoining garden walls, soffits, porches, posts etc. Exposed tops of walls require waterproofing and should be finished with block caps Exterior Insulation - refer to Sto Concrete Block Insulation Details NZBC Acceptable Solution H1/AS1 or NZBC Verification Method H1/VM1 can be used for housing, communal residential, communal non-residential and commercial buildings. For buildings with a glazing area of 30% or less of the total wall area, the minimum wall R-values required for solid construction are: Climate Zone 1 (Nth Coromandel) - R0.8 (option 1a and 1b) Climate Zone 2 Nth Island, Sth Coromandel excluding the Central Plateau - R1.0 (option 2a) or R0.9 (option 2b) Climate Zone 3 Sth Island and Central Plateau) - R1.2 (option 3a) or R1.0 (option 3b) Refer to the BRANZ House Insulation Guide Third Edition for further information and construction R-values for concrete block construction with External Insulation. Interior Insulation Generally involves 90mm framing inside and installing insulation to meet 1.9 or 2.0 R-Value Note: H1 Insulation - Internally insulated masonry walls must meet the timber insulation code STO CONCRETE BLOCK STO CONCRETE BLOCK CB 005 CONSTRUCTION & DETAILING 2014 The information contained in this detail is based on our experience and testing and represents the latest information available at the date of issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications. STO CONCRETE BLOCK PLASTER SYSTEM StoArmat Reinforced Plaster System To combat fractures and stress that can occur in concrete block construction during the curing and settling process. The StoFlexyl waterproofing membrane is to ensure openings, junctions, terminations and overlays are waterproofed. SS202 STOARMAT MIRAL PLASTER SYSTEM BRANZ APPRAISAL CERTIFICATE No.515 INCORPORATING: 1. 2. 3. 4. Stoflexyl Waterproofing 18Kg pail plus cement evaluated by BRANZ to meet AS/NZS4858 waterproofing membrane requirements as required by NZBC E2/AS1 Levellite Base Plaster 20Kg bag mineral fibre reinforced based plaster with EPS bead for levelling and straightening walls. Can be machine applied StoArmat Classic Plaster 23Kg pail European fibre reinforced non-cement based crack resistant plaster used with European mesh as a reinforcement plaster Stolit Coloured Finishing Render in 25Kg Pail Stolit K - 1.0mm Coloured Float Finish Render 1.5mm Coloured Float Finish Render 2.0mm Coloured Float Finish Render 3.0mm Coloured Float Finish Render Stolit - MP Fine Sponge or Adobe Coloured Finishing Render MP Natural Sponge or Adobe Coloured Finishing Render Milano Smooth or Adobe Coloured Finishing Render STO CONCRETE BLOCK STO CONCRETE BLOCK PLASTER SYSTEM CB 006 2014 The information contained in this detail is based on our experience and testing and represents the latest information available at the date of issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications. STOARMAT MIRAL PLASTER SYSTEM - SS202 BASECOAT: LEVELLITE 6/8mm PLASTER REINFORCEMENT: STOARMAT CLASSIC PLASTER PLUS: STO EUROPEAN MESH SKIM COAT: STOARMAT CLASSIC PLASTER FINISHING RENDER: STOLIT K & MP RANGE STOLIT K COLOURED FINISH RENDER 1.0, 1.5, 2.0 & 3.0mm FLOAT FINISH. STOLIT MP COLOURED FINISH RENDER MP, MP NATURAL & MILANO FINE FINISH COATING/STO COLOR: :MAXICRYL MATT FACADE PAINT :LASTIC SATIN FACADE PAINT :LOTUSAN MINERAL RESIN PAINT SCALE 1:20 STO CONCRETE BLOCK STO CONCRETE BLOCK CB 100 STOARMAT MIRAL PLASTER SYSTEM - ISOMETRIC 2014 The information contained in this detail is based on our experience and testing and represents the latest information available at the date of issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications. CONCRETE MASONRY WALL INSULATION as per NZBC - H1 50 100mm 150 50 DPC CONCRETE SLAB/REINFORCING AS PER NZS 4229 & 4210 OR ENGINEER SPECIFIC DESIGN SLAB INSULATION DPM SCALE 1:5 STO CONCRETE BLOCK STO CONCRETE BLOCK CB 200 REBATED SLAB-ON-GROUND 2014 The information contained in this detail is based on our experience and testing and represents the latest information available at the date of issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications. CONCRETE MASONRY WALL INSULATION as per NZBC - H1 150mm unpaved 100mm paved STOARMAT MIRAL PLASTER SYSTEM 100mm STOFLEXYL MESH OVER SLAB TO BLOCK JUNCTION STOFLEXYL - BRUSH SHEETS & FOUNDATION ADHESIVE MORTAR TO FACE AND MECHANICAL FIX @ 600mm CTRS ABOVE GROUND SCABBLE SLAB SURFACE FOR BLOCK BOND STO FLEXYL WATERPROOFING SHALL EXTEND ABOVE GROUND BY AT LEAST 150mm AND IF DPM IS APPLIED TO THE EXTERNAL FACE OF FOOTING IT SHALL OVERLAP BY AT LEAST 50mm CONCRETE SLAB/REINFORCING AS PER NZS 4229 & 4210 OR ENGINEER SPECIFIC DESIGN DPM REQUIRED FOR POORLY DRAINED SITES SCALE 1:5 STO CONCRETE BLOCK STO CONCRETE BLOCK CB 201 NON-REBATED SLAB-ON-GROUND 2014 The information contained in this detail is based on our experience and testing and represents the latest information available at the date of issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications. CONCRETE MASONRY WALL INSULATION as per NZBC - H1 G.L 50 STOFLEXYL WATERPROOFING SHALL EXTEND ABOVE GROUND BY AT LEAST 150mm AND IF DPM IS APPLIED TO THE EXTERNAL FACE OF FOOTING IT SHALL OVERLAP BY AT LEAST 50mm 150 STOARMAT MIRAL PLASTER SYSTEM see note NOTE: REFER TO NZS 4229 or SPECIFIC DESIGN FOR DIMENSION, REINFORCING AND GROUND CLEARANCES see note SCALE 1:10 STO CONCRETE BLOCK STO CONCRETE BLOCK CB 202 STRIP FOOTING DETAIL 2014 The information contained in this detail is based on our experience and testing and represents the latest information available at the date of issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications. TRANSITION APPROX.100mm BELOW GROUND GRANDULAR FILL RECOMMENDED SELECTED BITUMOUS PEEL & STICK TANKING MEMBRANE WITH PROTECTION MATERIAL STO CONCRETE BLOCK 150 100 STOARMAT MIRAL PLASTER SYSTEM STOFLEXYL MESHED WATERPROOFING FROM 150mm ABOVE GROUND AND DOWN OVER COMPRESSION BAR NOTE: REFER TO NZS 4229 or SPECIFIC DESIGN FOR DIMENSION & REINFORCING TANKING SEALANT COMPRESSION BAR MECHANICALLY FIXED TO CONC.BLOCK STO CONCRETE BLOCK CB 203 TANKING TO PLASTER TRANSITION 2014 The information contained in this detail is based on our experience and testing and represents the latest information available at the date of issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications. BLOCK CONTROL JOINT BASECOAT: LEVELLITE 6/8mm REINFORCEMENT: STOARMAT CLASSIC STO 8 mm uPVC JOINT IN STOARMAT MESH COAT FINISHING RENDER: STOLIT K & MP RANGE VERTICAL CONTROL JOINTS AT BLOCK CONTROL JOINTS - NORMALLY @6.0M CENTERS or AS PER PROJECT DRAWINGS NOTE: WHEN FITTING THE STO CONTROL JOINT, PULL TAB 75mm OUT TO ENSURE EASIER REMOVAL. BED JOINT IN STOARMAT CLASSIC MESH COAT. THE FINISHED JOINT MUST BE COATED FOR NEGATIVE DETAIL or FILLED WITH MS SEALANT. REMOVE TABS AS SOON AS JOINT IS SET TO AVOID CRACKING SCALE 1:20 STO CONCRETE BLOCK STO CONCRETE BLOCK CB 300 VERTICAL CONTROL JOINT 2014 The information contained in this detail is based on our experience and testing and represents the latest information available at the date of issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications. 100 STOFLEXYL WATERPROOFING 150mm MIN.ABOVE & BELOW STAIRS WITH 50mm MIN.UNDER PLASTERED STAIRS or TILE MEMBRANE CONCRETE MASONRY WALL (20 Series shown) INSULATION AS PER NZBC - H1 50mm APPLY STOFLEXYL MESHED BAND ON CONC.BLOCKS 150mm MIN. ABOVE AND 150mm BELOW STAIRS BEFORE BOXING - APPLY STOFLEXYL MESH, 50mm MIN.ONTO STAIRS ONCE CONCRETE HAS CURED BEFORE PLASTERING OR APPLYING TILE MEMBRANE STOFLEXYL WATERPROOFING MEMBRANE • • • • • • STO CONCRETE BLOCK WALL CAPS, PARAPETS, BALUSTRADE TOPS JOINERY OPENINGS TIMBER OVERLAYS & SOFFITS STAIRS ADJACENT GARDEN WALLS FOUNDATIONS STO CONCRETE BLOCK CB 301 STAIR WATERPROOFING DETAIL 2014 The information contained in this detail is based on our experience and testing and represents the latest information available at the date of issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications. CONCRETE MASONRY WALL (20 Series shown) STOARMAT MIRAL PLASTER SYSTEM INTER-STOREY FLOOR SLAB - REINFORCING NOT SHOWN FOR CLARITY DPC STOFLEXYL MESH COAT OVER FLOOR JUNCTION IF FLOOR SLAB PENETRATES EXT.CONC.BLOCK INSULATION AS PER NZBC - H1 SCALE 1:10 STO CONCRETE BLOCK STO CONCRETE BLOCK CB 302 INTER-STOREY SLAB DETAIL 2014 The information contained in this detail is based on our experience and testing and represents the latest information available at the date of issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications. CONCRETE MASONRY WALL INSULATION AS PER NZBC - H1 5° MIN.SLOPE TO OUTSIDE SECURE PIPE, APPLY SEALANT PLASTER AND REAPPLY SEALANT ON MESH COAT BEFORE FINISHING PIPE OR OTHER PENETRATION SLOPED DOWNWARD - TOWARD THE OUTSIDE 8/10mm SEALANT BEAD ON PEF ROD BETWEEN PIPE AND PLASTER INTERIOR EXTERIOR SCALE 1:5 STO CONCRETE BLOCK STO CONCRETE BLOCK CB 350 PIPE PENETRATION DETAIL (up to150mm) 2014 The information contained in this detail is based on our experience and testing and represents the latest information available at the date of issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications. METER BOX AT HEAD PROVIDE AIRSEAL POLYSTYRENE INSULATION TO SUIT APPLY STOARMAT MIRAL PLASTER SYSTEM WITH STO uPVC DRIP EDGE AT HEAD PREPARE REBATES, APPLY TWO (2) COATS OF STOFLEXYL WATERPROOFING BEFORE APPLYING STOARMAT MIRAL SYSTEM. LEAVE 10mm SEALANT JOINT MS SEALANT OVER STO JOINT SEAL TAPE TO PERIMETER OF METERBOX THICKEN BASECOAT ON REBATES TO ACHIEVE A 6-8mm FINISHING GAP BEFORE SEALING METER BOX AT SILL PROVIDE AIRSEAL MS SEALANT OVER STO JOINT SEAL TAPE PREPARE REBATES, AND APPLY TWO (2) COATS OF STOFLEXYL WATERPROOFING BEFORE APPLYING STOARMAT MIRAL PLASTER SYSTEM. LEAVE 10mm SEALANT JOINT STOARMAT MIRAL PLASTER SYSTEM SCALE 1:5 STO CONCRETE BLOCK STO CONCRETE BLOCK CB 351 METER BOX 2014 The information contained in this detail is based on our experience and testing and represents the latest information available at the date of issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications. CONCRETE MASONRY WALL INSULATION AS PER NZBC - H1 SLOPE TO O UTSIDE FAN VENT COVER STOARMAT MIRAL PLASTER SYSTEM MS SEALANT TO PERIMETER LEAVE 40mm DRAINAGE GAP IN MIDDLE MS SEALANT AT PIPE JUNCTION (FIX FAN COVER TO FLEXIBLE PIPE AS PER MANUFACTURERS INSTRUCTION) USE STO JOINT SEAL TAPE TO SEAL TO CONCRETE BLOCK SCALE 1:5 STO CONCRETE BLOCK STO CONCRETE BLOCK CB 352 FAN VENT DETAIL 2014 The information contained in this detail is based on our experience and testing and represents the latest information available at the date of issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications. CONCRETE MASONRY WALL INSULATION AS PER NZBC - H1 STOARMAT MIRAL PLASTER SYSTEM ADHESIVE ADHERE ARCHITECTURAL PROFILES AND USE STOTHERM FIXINGS AS NECESSARY PREMESHED ARCHITECTURAL PROFILE OVER STOARMAT/MESH COAT MESH COAT UNDER PROFILE SCALE 1:5 STO CONCRETE BLOCK STO CONCRETE BLOCK CB 353 ARCHITECURAL PROFILE 2014 The information contained in this detail is based on our experience and testing and represents the latest information available at the date of issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications. 75 75 HANDRAIL DESIGN & HEIGHT IN ACCORDANCE WITH NZBC HANDRAIL PLATE ON EPDM GASKET WITH EPDM WASHERS UNDER FIXING WASHERS STOFLEXYL MESHED WATERPROOFING WITH 75mm DOWNTURM OVER BASECOAT FINISHED IN STOARMAT MIRAL PLASTER SYSTEM SELECTED CONC.BLOCK SERIES (shown 20 series conc.block) METAL OVERFLASHING SEALED INTO WALL CHASE (20mm x 10mm) & WITH MASONRY FIXINGS ROOF MEMBRANE FLASHING CHASED INTO WALL SELECTED ROOF MEMBRANE ROOF SCREED TO A FALL MIN FALL1.5° CONCRETE ROOF SLAB INSULATION AS PER NZBC - H1 SCALE 1:5 STO CONCRETE BLOCK STO CONCRETE BLOCK CB 354 HANDRAIL 2014 The information contained in this detail is based on our experience and testing and represents the latest information available at the date of issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications. 70 STOARMAT MIRAL PLASTER SYSTEM SELECTED CONC.BLOCK SERIES (shown 20 series conc.block) PROPRIETARY SCUPPER OUTLET - CUT TO SUIT REBATE INTO SUBSTRATE STO uPVC FINISHING EDGE TO PLASTER METAL OVER-FLASHING TO BE CHASED AND SEALED INTO WALL WITH MS SEALANT SELECTED MEMBRANE low point 50mm DRIP EDGE BACKING ROD & STO SEAL JOINT INSTALLED AROUND PERIMETER OF OPENING SECURE RWH WITH MASONRY FIXINGS WITH EDPM WASHER BETWEEN RWH AND STO PLASTER FINISH MASONRY FIXING CUSTOM FOLDED RAIN WATER HEAD DEBRIS SCREEN H3.1 JOISTS, LAID TO A FALL INSULATION AS PER NZBC - H1 SCALE 1:5 STO CONCRETE BLOCK STO CONCRETE BLOCK CB 355 RWH/SCUPPER OPENING 2014 The information contained in this detail is based on our experience and testing and represents the latest information available at the date of issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications. HEAD DETAIL PREPARE REBATES AND BRUSH APPLY TWO (2) COATS OF STO FLEXYL WATERPROOFING TO HEAD & JAMB REBATES BEFORE INSTALLING JOINERY 20 SERIES CONCRETE MASONRY WALL INSULATION AS PER NZBC - H1 5 STO PREMESHED DRIP EDGE AT HEAD MS SEALANT CONTINUOUS ACROSS HEAD & DOWN JAMBS SILL DETAIL 5 5 BRUSHED STOFLEXYL COAT 20 SERIES CONCRETE MASONRY WALL 10 PROPRIETARY ALU.WINDOW JOINERY PREPARE REBATES AND APPLY STO FLEXYL MESHED WATERPROOFING TURNED 40mm UP JAMBS REMOVE PROJECTING SILL (as requested) SHOWN DASHED STOARMAT MIRAL PLASTER SYSTEM INSULATION AS PER NZBC - H1 SCALE 1:5 STO CONCRETE BLOCK STO CONCRETE BLOCK CB 400 ALUMINIUM JOINERY - HEAD & SILL DETAIL 2014 The information contained in this detail is based on our experience and testing and represents the latest information available at the date of issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications. INSULATION AS PER NZBC - H1 20 SERIES CONCRETE MASONRY WALL - REINFORCED AS PER NZS 4229 5 PROPRIETARY ALU.WINDOW JOINERY STOARMAT MIRAL PLASTER SYSTEM MS SEALANT CONTINUOUS AROUND HEAD & JAMBS PREPARE REBATES; BRUSH APPLY TWO (2) COATS OF STO FLEXYL WATERPROOFING TO JAMB & HEAD REBATES BEFORE INSTALLING JOINERY SCALE 1:5 STO CONCRETE BLOCK STO CONCRETE BLOCK CB 401 ALUMINIUM JOINERY - JAMB DETAIL 2014 The information contained in this detail is based on our experience and testing and represents the latest information available at the date of issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications. 20 SERIES CONCRETE MASONRY WALL INSULATION AS PER NZBC - H1 PREPARE REBATES AND BRUSH APPLY TWO (2) COATS OF STO FLEXYL WATERPROOFING TO ALL REBATES BEFORE INSTALLING JOINERY 5 STO PREMESHED DRIP EDGE MS SEALANT CONTINUOUS AROUND HEAD & JAMBS LINE OF CONCRETE BLOCK & FOUNDATION SHOWN DASHED 10mm MIN. TIMBER SILL - ADJUST PACKER TO SUIT FLOOR COVERINGS 5mm PROPRIETARY ALU.DOOR JOINERY PREPARE REBATES AND BRUSH APPLY STO FLEXYL WATERPROOFING STOARMAT MIRAL PLASTER SYSTEM 150mm MIN.FLOOR SLAB to GROUND LEVEL 100mm MIN.FLOOR SLAB to PAVING SCALE 1:5 STO CONCRETE BLOCK STO CONCRETE BLOCK CB 402 ALU.JOINERY-DOOR HEAD & THRESHOLD DETAIL 2014 The information contained in this detail is based on our experience and testing and represents the latest information available at the date of issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications. INSULATION AS PER NZBC - H1 20 SERIES CONCRETE BLOCK AIRSEAL ON PEF ROD GAP 7.5-8mm APPROX & PACKER 5 STOARMAT MIRAL PLASTER SYSTEM PROPRIETARY ALU.DOOR JOINERY MS SEALANT CONTINUOUS AROUND HEAD & JAMBS PREPARE REBATES AND BRUSH APPLY TWO (2) COATS OF STO FLEXYL WATERPROOFING TO ALL REBATES BEFORE INSTALLING JOINERY SCALE 1:5 STO CONCRETE BLOCK STO CONCRETE BLOCK CB 403 ALUMINIUM JOINERY - JAMB DETAIL 2014 The information contained in this detail is based on our experience and testing and represents the latest information available at the date of issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications. STOARMAT MIRAL PLASTER SYSTEM 20 SERIES CONCRETE MASONRY WALL PREPARE REBATES AND BRUSH APPLY TWO (2) COATS OF STO FLEXYL WATERPROOFING TO ALL REBATES BEFORE INSTALLING JOINERY ON DPC & PLASTERING STO PREMESHED DRIP EDGE INSULATION AS PER NZBC - H1 AIR SEAL OVER BACKING ROD MS SEALANT CONTINUOUS ACROSS HEAD & DOWN JAMBS. TIMBER TRIM TIMBER JOINERY PROFILES AS PER NZS 3610 PREPARE REBATES AND BRUSH APPLY STO FLEXYL TO INTERNAL REBATE WITH MESH WATERPROOFING TURNED 40mm UP JAMBS OVER SILL H3.2 TIMBER PACKER ON DPC UNDER SILL INSULATION AS PER NZBC - H1 REMOVE PROJECTING SILL SHOWN DASHED 20 SERIES CONCRETE MASONRY WALL STOARMAT MIRAL PLASTER SYSTEM SCALE 1:5 STO CONCRETE BLOCK STO CONCRETE BLOCK CB 404 TIMBER JOINERY - HEAD & SILL DETAIL 2014 The information contained in this detail is based on our experience and testing and represents the latest information available at the date of issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications. INSULATION/STAPPING AND LINING 20 SERIES CONCRETE MASONRY WALL AIR SEAL OVER BACKING ROD MS SEALANT CONTINUOUS ACROSS HEAD & JAMBS, TIMBER TRIM STOARMAT MIRAL PLASTER SYSTEM PREPARE REBATES AND BRUSH APPLY STO FLEXYL MESHED WATERPROOFING TURNED 40mm UP JAMBS SCALE 1:5 STO CONCRETE BLOCK STO CONCRETE BLOCK CB 405 TIMBER JOINERY - JAMB DETAIL 2014 The information contained in this detail is based on our experience and testing and represents the latest information available at the date of issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications. 20 SERIES CONCRETE BLOCK STOARMAT MIRAL PLASTER SYSTEM 50 INSULATION/STAPPING AND LINING AIR SEAL OVER BACKING ROD APPLY TWO (2) COATS OF STO FLEXYL WATERPROOFING TO ALL REBATES OVER BASE COAT 50mm MIN.UP FACE OF MASONRY WALL STO PREMESHED DRIP EDGE SEALANT OVER BOND BREAKER CONTINUOUS ACROSS HEAD & JAMB LINE OF CONCRETE BLOCK & FOUNDATION SHOWN DASHED 50 * REBATE TO SUIT SILL PROFILE * TIMBER DOOR JOINERY PROFILES AS PER NZS 3610 APPLY TWO COATS OF STO FLEXYL WATERPROFFING TO ALL REBATES OVER BASECOAT 50mm MIN.DOWN WALL SCALE 1:5 STO CONCRETE BLOCK STO CONCRETE BLOCK CB 406 TIMBER DOOR JOINERY - HEAD & SILL DETAIL 2014 The information contained in this detail is based on our experience and testing and represents the latest information available at the date of issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications. INSULATION/STAPPING AND LINING (indicative only, not req.for weathertightness) 20 SERIES CONCRETE BLOCK AIRSEAL ON PEF ROD GAP 7.5-8mm APPROX & PACKER TIMBER DOOR JOINERY PROFILES AS PER NZS 3610 50 STOARMAT MIRAL PLASTER SYSTEM ALU.EQUAL ANGLE SEALANT OVER BOND BREAKER CONTINUOUS ACROSS HEAD & JAMB APPLY TWO COATS OF STO FLEXYL WATERPROFFING TO ALL REBATES OVER BASECOAT 50mm MIN.DOWN WALL SCALE 1:5 STO CONCRETE BLOCK STO CONCRETE BLOCK CB 407 TIMBER DOOR JOINERY - JAMB DETAIL 2014 The information contained in this detail is based on our experience and testing and represents the latest information available at the date of issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications. 50 50 METAL CAPPING WITH 5° MIN.FALL TO PARAPET MASONRY FIXINGS 5° PROVIDE SEPARATION (ROOF UNDERLAY) UNDER METAL CAPPING OVER 9mm H3 PLY ON DPC SELECTED CONC.BLOCK SERIES (shown 20 series conc.block) STOARMAT MIRAL PLASTER SYSTEM NOTE: CUT BLOCK TO SUIT OR BASECOAT PLASTER TO A FALL APPROX.18mm FROM FRONT EDGE BEFORE INSTALLING PLYWOOD ON DPC. ALTERNATIVELY USE H3.1 TIMBER PLATE, MAINTAINING FLASHING COVER OVER CONC.BLOCK OF 50mm MIN. SCALE 1:5 STO CONCRETE BLOCK STO CONCRETE BLOCK CB 500 PARAPET/METAL FLASHING DETAIL 2014 The information contained in this detail is based on our experience and testing and represents the latest information available at the date of issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications. 75 75 10° STOFLEXYL MEMBRANE UNDER MESH COAT TO TOP & SIDES, 75mm DOWNTURN OVER LEVELITE BASE COAT CUT CONC.BLOCK TO FORM REQUIRED SLOPE OF 10° MIN. SELECTED CONC.BLOCK SERIES (shown 20 series conc.block) STOARMAT MIRAL PLASTER SYSTEM NOTE: CUT BLOCKS TO SUIT or BASECOAT PLASTER TO A FALL 10° MIN.FOR STOCLEAR COATING SYSTEM REFER TO DRAWING DETAIL CB 502 SCALE 1:5 STO CONCRETE BLOCK STO CONCRETE BLOCK CB 501 PLASTERED PARAPET/BALUSTRADE DETAIL 2014 The information contained in this detail is based on our experience and testing and represents the latest information available at the date of issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications. 15 5 STOFLEXYL MESHED WATERPROOFING MORTAR BED 15mm 5mm FALL TO INTERIOR SIDE SELECTED CONC.BLOCK SERIES (shown 20 series conc.block) PAINTED, CLEAR COATED or PLASTERED FINISH SCALE 1:5 STO CONCRETE BLOCK STO CONCRETE BLOCK CB 502 UNCOATED,PAINTED CLEAR COATED or PLASTERED 2014 The information contained in this detail is based on our experience and testing and represents the latest information available at the date of issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications. 10° 75 75 CUT CONCRETE BLOCK TO FORM REQUIRED SLOPE OF 10° MIN. STOFLEXYL MEMBRANE UNDER MESH COAT TO TOP & SIDES, 75mm DOWNTURN OVER LEVELITE BASE COAT SELECTED CONC.BLOCK SERIES (shown 20 series conc.block) STOARMAT MIRAL PLASTER SYSTEM STO STICK ON CONNECTOR OR STO uPVC FINISHING EDGE & MS SEALANT AT FLASHING 150 SELECTED ROOF MEMBRANE 70 METAL OVERFLASHING SEALED INTO WALL CHASE (20mm x 10mm) & FIXED WITH A MASONRY FIXINGS SELECTED ROOF MEMBRANE UPSTAND150mm MIN. ROOF SCREED TO A MIN FALL1.5° CONCRETE ROOF SLAB INSULATION AS PER NZBC - H1 SCALE 1:5 STO CONCRETE BLOCK STO CONCRETE BLOCK PARAPET/ROOF/WALL DETAIL CB 503 2014 The information contained in this detail is based on our experience and testing and represents the latest information available at the date of issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications. SELECTED CONC.BLOCK SERIES (shown 20 series conc.block) 75 LEVELLITE BASECOAT OVERLAY OF STOFLEXYL MESHED WATERPROOFING TO TOP & SIDES - 75mm DOWNTURN OVER BASE COAT NOTE: 1. ALL ADJACENT WALLS ARE TO BE STRUCTURALLY TIED WITH STEEL REINFORCEMENT. 2. BALUSTRADES TO HAVE 10° MIN.FALL TO TOP 3. ALL BALUSTRADES/PARAPETS & WALL CAPS TO HAVE STOFLEXYL MESHED WATERPROOFING 4. STO FLEXYL MESHED WATERPROOFING MEMBRANE HAS BEEN TESTED BY BRANZ TO AS/NZS4858 - AS REQUIRED BY E2/AS1 & CCANZ CP01:2014 SCALE 1:20 STO CONCRETE BLOCK STO CONCRETE BLOCK CB 504 STOFLEXYL WATERPROOFING MEMBRANE 2014 The information contained in this detail is based on our experience and testing and represents the latest information available at the date of issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications. PRE FINISHED METAL ROOFING OVER ROOF UNDERLAY 60mm 50 mm H3.1 PRE PRIMED & PAINTED FASCIA/BARGE BOARD MIN.COVER M12 BOLT FIXING SOFFIT FRAMING SOFFIT LINING MS SEALANT 6-8mm, WATERPROOF CONC.BLOCK BEFORE INSTALLING SOFFIT STOARMAT MIRAL PLASTER SYSTEM TO TOP OF WALL 20 SERIES CONCRETE MASONRY WALL INSULATION AS PER NZBC - H1 NOTE: EAVE FLASHING REQUIRED WHERE • ROOF SLOPE LESS THAN OR EQUAL TO 10° • SOFFIT WIDTH LESS THAN OR EQUAL TO 100mm • WIND ZONES ARE VERY HIGH or EXTRA HIGH SCALE 1:5 STO CONCRETE BLOCK STO CONCRETE BLOCK CB 600 EAVES WITH OVERHANG 2014 The information contained in this detail is based on our experience and testing and represents the latest information available at the date of issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications. 125 COMPLIANT EAVE FLASHING/E2/AS1 PRE FINISHED METAL ROOFING OVER ROOF UNDERLAY 35 PURLIN - REFER NZS 3604 50 mm H3.1 PRE PRIMED & PAINTED FASCIA/BARGE BOARD MIN.COVER M12 BOLT FIXING STOARMAT MIRAL PLASTER SYSTEM TO TOP OF WALL 20 SERIES CONCRETE MASONRY WALL INSULATION AS PER NZBC - H1 NOTE: EAVE FLASHING REQUIRED WHERE • ROOF SLOPE LESS THAN OR EQUAL TO 10° • SOFFIT WIDTH LESS THAN OR EQUAL TO 100mm • WIND ZONES ARE VERY HIGH or EXTRA HIGH, MS SEALANT REQUIRED SCALE 1:5 STO CONCRETE BLOCK STO CONCRETE BLOCK CB 601 EAVES WITH NO OVERHANG 2014 The information contained in this detail is based on our experience and testing and represents the latest information available at the date of issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications. PRE FINISHED METAL ROOFING OVER ROOF UNDERLAY PURLIN - REFER NZS 3604 PRE FINISHED METAL FLASHING LAP - REFER NZBC, TABLE 7 MIN.2 x crests E2/AS1 50/90 RAFTER - REFER NZS 3604 FOR SIZE BOLT FIXING FLYING RAFTER OUTRIGGER RAKING WALL PLATE ON DPC SOFFIT LINING H3.1 PRE PRIMED & PAINTED FASCIA/BARGE BOARD 20 x 20mm SCOTIA BEAD STO 6mm FINISHING EDGE STOARMAT MIRAL PLASTER SYSTEM 20 SERIES CONCRETE MASONRY WALL INSULATION AS PER NZBC - H1 SCALE 1:5 STO CONCRETE BLOCK STO CONCRETE BLOCK CB 602 BARGE WITH OVERHANG 2014 The information contained in this detail is based on our experience and testing and represents the latest information available at the date of issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications. 75 35 110mm Upstand for flashing STOFLEXYL MESHED WATERPROOFING 75mm MIN.DOWNTURN OVER BASECOAT STO uPVC FINISHING EDGE TO PLASTER AND MS SEALANT AT FLASHING JUNCTION METAL OVER-FLASHING TO BE CHASED AND SEALED INTO WALL WITH MS SEALANT PROFILED ROOF FLASHING & UNDERLAY TO RUN UP BENEATH OVER-FLASHING AND TO BE MECHANICALLY FIXED TO WALL PURLIN - REFER NZS 3604 RAFTER - REFER NZS 3604 FOR SIZE SELECTED CONC.BLOCK SERIES (shown 20 series conc.block) STOARMAT MIRAL PLASTER SYSTEM INSULATION/STAPPING AND LINING SCALE 1:5 STO CONCRETE BLOCK STO CONCRETE BLOCK CB 603 ROOF TO CONC.BLOCK GABLE END 2014 The information contained in this detail is based on our experience and testing and represents the latest information available at the date of issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications. PRE FINISHED METAL ROOFING OVER ROOF UNDERLAY 50 SELECTED FIBRE CEMENT SOFFIT LINING 6mm MAX.GAP WITH MS SEALANT or STO JOINT SEAL TAPE BRUSH STOFLEXYL WATERPROOFING TO CONC.BLOCK - 50mm MIN. PAST SOFFIT STOARMAT MIRAL PLASTER SYSTEM NOTE: MAX.ANGLE OF SOFFIT RESTRICTED TO BETWEEN 91° - 115° • SOFFITS ARE FIXED AFTER PLASTERING 20 SERIES CONCRETE MASONRY WALL INSULATION/STAPPING AND LINING • STO CONCRETE BLOCK SCALE 1:10 STO CONCRETE BLOCK CB 604 RAKING SOFFIT (REVERSED) 2014 The information contained in this detail is based on our experience and testing and represents the latest information available at the date of issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications. 75 35 110mm Upstand for flashing STOARMAT MIRAL PLASTER SYSTEM STO uPVC FINISHING EDGE TO PLASTER WITH MS SEALANT METAL OVER-FLASHING TO BE CHASED AND SEALED INTO WALL WITH MS SEALANT SECURED WITH MASONRY FIXINGS Refer E2/AS1 table 7 PROFILED ROOF APRON FLASHING & ROOF UNDERLAY TO RUN UP BEHIND FLASHING TIMBER ROOF STRUCTURE NOTE: INSTALL DIVERTER FLASHING AT ROOF/GUTTER JUNCTION SCALE 1:5 STO CONCRETE BLOCK STO CONCRETE BLOCK CB 700 GABLE END/ROOF JUNCTION 2014 The information contained in this detail is based on our experience and testing and represents the latest information available at the date of issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications. 75 35 110mm Upstand for flashing STO uPVC FINISHING EDGE TO PLASTER WITH MS SEALNT METAL OVER-FLASHING TO BE CHASED AND SEALED INTO WALL WITH MS SEALANT SECURED WITH MASONRY FIXINGS Refer PROFILED ROOF, APRON E2/AS 1 Tab FLASHING & ROOF UNDERLAY TO le 7 RUN UP BEHIND FLASHING TIMBER ROOF STRUCTURE NOTE: ENSURE APRON FLASHING IS OVER FLASHED AT BOTH ENDS SCALE 1:5 STO CONCRETE BLOCK STO CONCRETE BLOCK CB 701 APRON FLASHING 2014 The information contained in this detail is based on our experience and testing and represents the latest information available at the date of issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications. 20mm 75 35 110mm Upstand for flashing STOARMAT MIRAL PLASTER SYSTEM STO uPVC FINISHING EDGE TO PLASTER WITH MS SEALANT METAL OVER-FLASHING TO BE CHASED AND SEALED INTO WALL WITH MS SEALANT SECURED WITH MASONRY FIXINGS 80mm 80mm TIMBER ROOF STRUCTURE SCALE 1:5 STO CONCRETE BLOCK STO CONCRETE BLOCK CB 702 PARALLEL ROOF/HIDDEN GUTTER 2014 The information contained in this detail is based on our experience and testing and represents the latest information available at the date of issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications. MIN. 5mm RADIUS TO PLYWOOD 50mm MIN.LAP REFER E2/AS1 S/S ANGLE 50 SELECTED MEMBRANE FINISH OVER H3"C" FACED PLYWOOD LAID TO A 1:30MIN.FALL GLUE & SCREW TO TIMBER FRAMING, ALL EDGES SUPPORTED H3.1 PRE PRIMED & PAINTED FASCIA/BARDGE BOARD MS SEALANT ON STO SEAL TAPE 50 COVER PRE FINISHED METAL SPOUTING AND BRACKETS INSULATION AS PER NZBC - H1 20 SERIES CONCRETE MASONRY WALL STOARMAT MIRAL PLASTER SYSTEM SCALE 1:5 STO CONCRETE BLOCK STO CONCRETE BLOCK CB 703 FACE FIXED FASCIA/MEMBRANE ROOF 2014 The information contained in this detail is based on our experience and testing and represents the latest information available at the date of issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications. STOARMAT MIRAL PLASTER SYSTEM SELECTED CONC.BLOCK SERIES (shown 20 series conc.block) INSULATION AS PER NZBC - H1 50mm MIN.COVER E2/AS1 COMPLIANT BACK FLASHING WITH MS SEALANT NOMINAL H3.1 TIMBER BATTEN SELECTED HORIZONTAL TIMBER WEATHERBOARDS OVER 20mm DRAINED CAVITY WALL UNDERLAY SCALE 1:5 STO CONCRETE BLOCK STO CONCRETE BLOCK EXTERNAL CORNER CB 800 2014 The information contained in this detail is based on our experience and testing and represents the latest information available at the date of issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications. INSULATION AS PER NZBC - H1 SELECTED CONC.BLOCK SERIES (shown 20 series conc.block) STO uPVC FINISHING EDGE WITH MS SEALANT NOMINAL H3.1 TIMBER BATTEN SELECTED HORIZONTAL TIMBER WEATHERBOARDS OVER 20mm DRAINED CAVITY 50mm MIN.COVER STOARMAT MIRAL PLASTER SYSTEM E2/AS1 COMPLIANT FLASHING IN CONC.BLOCK CHASE SCALE 1:5 STO CONCRETE BLOCK STO CONCRETE BLOCK INTERNAL CORNER CB 801 2014 The information contained in this detail is based on our experience and testing and represents the latest information available at the date of issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications. SELECTED FLOORING SELECTED HORIZONTAL TIMBER WEATHERBOARDS OVER 20mm DRAINED CAVITY WALL UNDERLAY JOISTS - REFER NZS3604:2011 FOR SIZE 15 50 WALL PLATE ON DPC CAVITY CLOSURE STOARMAT MIRAL PLASTER SYSTEM WITH STO uPVC FINISHING EDGE SELECTED CONC.BLOCK SERIES (shown 20 series conc.block) INSULATION/STAPPING AND LINING SCALE 1:5 STO CONCRETE BLOCK STO CONCRETE BLOCK CB 802 HORIZONTAL JUNCTION/WEATHERBOARD 2014 The information contained in this detail is based on our experience and testing and represents the latest information available at the date of issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications. SELECTED CONC.BLOCK SERIES (shown 20 series conc.block) STOARMAT MIRAL PLASTER SYSTEM E2/AS1 COMPLIANT FLASHING REBATED IN CHASE CUT INTO CONCRETE BLOCK MS SEALANT OVER PEF ROD FLASHING (SPECIFY COATING) INSULATION AS PER NZBC - H1 PROFILED FOAM CLOSURE STRIP UNDER CLADDING NOMINAL H3.1 TIMBER BATTEN HORIZONTAL PROFILED METAL WALL CLADDING SCALE 1:5 STO CONCRETE BLOCK STO CONCRETE BLOCK CB 850 EXTERNAL CORNER HORIZ.PROFILED METAL 2014 The information contained in this detail is based on our experience and testing and represents the latest information available at the date of issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications. SELECTED INTERNAL LININGS DPC INSULATION AS PER NZBC - H1 SELECTED CONC.BLOCK SERIES (shown 20 series conc.block) STOARMAT MIRAL SYSTEM MS SEALANT OVER PEF ROD PURPOSE MADE FLASHING (SPECIFY COATING) PROFILED FOAM CLOSURE STRIP UNDER CLADDING 27mm MIN.COVER E2/AS1 COMPLIANT BACK FLASHING CHASED INTO CONC.BLOCK NOMINAL H3.1 TIMBER BATTEN HORIZONTAL PROFILED METAL WALL CLADDING SCALE 1:5 STO CONCRETE BLOCK STO CONCRETE BLOCK CB 851 INTERNAL CORNER HORIZ.PROFILE METAL 2014 The information contained in this detail is based on our experience and testing and represents the latest information available at the date of issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications. SELECTED FLOORING HORIZONTAL PROFILED METAL CLADDING WALL UNDERLAY 20mm DRAINED & VENTED CAVITY JOISTS - REFER NZS3604 FOR SIZE WALL PLATE ON DPC CLOSE CAVITY VENTED E2/AS1 COMPLIANT FLASHING 15 50 CEILING BATTENS STOARMAT MIRAL PLASTER SYSTEM WITH STO uPVC FINISHING EDGE SELECTED CONC.BLOCK SERIES (shown 20 series conc.block) INSULATION AS PER NZBC - H1 SCALE 1:5 STO CONCRETE BLOCK STO CONCRETE BLOCK CB 852 HORIZONTAL JUNCTION/HORIZ.PROFILED METAL 2014 The information contained in this detail is based on our experience and testing and represents the latest information available at the date of issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications. SELECTED CONC.BLOCK SERIES (shown 20 series conc.block) DPC INSULATION AS PER NZBC - H1 20 STOARMAT MIRAL PLASTER SYSTEM E2/AS1 COMPLIANT BACK FLASHING MS SEALANT OVER PEF ROD VERTICAL PROFILED METAL WALL CLADDING SCALE 1:5 STO CONCRETE BLOCK STO CONCRETE BLOCK CB 853 EXTERNAL CORNER VERTICAL.PROFILED METAL 2014 The information contained in this detail is based on our experience and testing and represents the latest information available at the date of issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications. INSULATION AS PER NZBC - H1 SELECTED INTERNAL LININGS STOARMAT MIRAL PLASTER SYSTEM 50 SELECTED CONC.BLOCK SERIES (shown 20 series conc.block) E2/AS1 COMPLIANT BACK FLASHING CHASED INTO CONC.BLOCK MS SEALANT JOINT OVER PEF ROD VERTICAL PROFILED METAL WALL CLADDING SCALE 1:5 STO CONCRETE BLOCK STO CONCRETE BLOCK CB 854 INTERNAL CORNER VERTICAL PROFILE METAL 2014 The information contained in this detail is based on our experience and testing and represents the latest information available at the date of issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications. SELECTED FLOORING VERTICAL PROFILED METAL CLADDING WALL UNDERLAY JOISTS - REFER NZS3604 FOR SIZE WALL PLATE ON DPC 50 CEILING BATTENS 3.5 6 3.5mm VENTILATION GAP, NON VENTED CLOSER FLASHING STOARMAT MIRAL PLASTER SYSTEM WITH STO uPVC FINISHING EDGE SELECTED CONC.BLOCK SERIES (shown 20 series conc.block) INSULATION AS PER NZBC - H1 SCALE 1:5 STO CONCRETE BLOCK STO CONCRETE BLOCK CB 855 HORIZ.JUNCTION/VERTICAL PROFILED METAL 2014 The information contained in this detail is based on our experience and testing and represents the latest information available at the date of issue. This detail is intended for use by the design professional and users of Sto products to assist in developing specific project details to be used in conjunction with a Sto Specification. We reserve the right to alter or update information at any time without prior notice & it is the responsibility of the specifier and/or the project manager to insure that they have the current Sto details and specifications.